You are on page 1of 3

DataProcessing VERGALHÃO 6.3A1.

dst 8/17/2009

<<test condition>>
Actuators
Controller in use:Controller1
Test mode:Static test-Tensile Unit:SI
Use transducer Name Display polarity P I D
TD1 FORÇA Normal 177 5.3 0.0
TD2 POSIÇÃO Normal 180 5.0 0.0
VTD7 Stress Normal 177 5.3 0.0
VTD8 Strain Normal 176 0.0 0.0
Displacement: POSIÇÃO Gauge length(mm):100.0 Distance between grips(mm):192.0

Comment
Time: Test name: ENSAIO GG50 01
User name: Admin Temperature:
Humidity: Test temperature:
Test atmosphere: Hyd. pressure:
:
:

Specimen
Material name: GG50 Sample number:
Specimen shape: Round bar
Diameter Sectional area
2
mm mm
6.3000 31.1725

Load
First speed
Control TD Force speed Unit
POSIÇÃO 3.0000 mm/min

Second speed
Control TD Force speed Unit
FORÇA 1.0000 kN/sec

After detaching the extensometer


Control TD Force speed Unit
Stroke 1.0000 mm/sec

Speed change point


Monitor TD
None

Extensometer detaching point


Monitor TD
None

1/3
DataProcessing VERGALHÃO 6.3A1.dst 8/17/2009

Displacement start point


At test start

Breaking sensitivity
OFF

Breaking level
OFF

I-ACT D-ACT
ON ON

Data samp.
FORÇA POSIÇÃO Stress Strain
ON ON ON ON
Data sampling interval(sec) 0.10000

Alarm
Limit exceed TD(upper) Setting value Unit Action after alarm Alarm contact output
FORÇA 95.0000 kN Wave stop No output.
Limit exceed TD(lower) Setting value Unit Action after alarm Alarm contact output
FORÇA -95.0000 kN Wave stop No output.
<<Test result>>
Unit Characteristic value
Elastic modulus MPa 159053
Upper yield point-Stress MPa 876.494
Maximum point-Stress MPa 876.494
Breaking point-Stress MPa 688.620

2/3
DataProcessing VERGALHÃO 6.3A1.dst 8/17/2009

Extraction data XY graph

900
850
800
750
700
650
600
550
Stress(MPa)

500
450
Strain - Stress
400 X: -0.380446 ~ 8.10538 %
Y: -35.0501 ~ 919.901 MPa
350
300
250
200
150
100
50
0

0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00

Strain(%)

3/3