o = DIMMER RACK
New Dimming Technology Coupled with Efficient Design

l ENR 96 contains forty-eight Free-standing dimmer rack: 80 H x 14'W x 19 D


plug-in dimmer modules Lightweight - 122 lbs, 245 lbs including
available in120 volt dual control and dimmer modules.
1 .8kW, 2.4kW and single

6.0kW capacities, 240 volt dual


2.5kW and single 5.0kW
capacities.
ft Plug-in dimmer and conlrol
modules make the ENR 96
rack f ully serviceable.
-l Removable top and bottom
access panels ior line and load
runs. Quickly and easily installed.
ENR 96 rack design allows
for adjacent or back-to-back
mounting of multiple racks.

o' Locking door io prevent


unwarranled access to
ENR 96 dimmer rack.
Ambient air is drawn through the
djmmers and exhausted through
the rack. The airflow is not drawn
over any electrical connections.
No liller is required.
l-'l Designed to operate on single
or three phase power,
120 or 240 volts.
I Ninety-six user programmable
panic switches are located
inside ihe ENR 96 rack.
100,000 A inlerrupt capacity
available.

Maintenance {ully f ront


-
accessible - no side or back
ENR Lniversal Dimmer N,4odule operates
with incandescent, fluorescent, low voltage,
access required. neon, cold cathode and non-dim loads.
Each module consists of a fully enclosed two piece
I UL Listed "engineering grade plastic chassis.
Compact design Each module ls 1.25"H x 12.0"W x 4.0"D.
J CSA Certif ied
Lightweight Total dimmer module weight: 2.5 lbs.
-
Ccopy''qrr Novemoe' '98q LLL Co o.lrrr, 1 ..

LEEColortran
Power bussing for simplified
rack interconnection and greater LEEcolortran
access for all contractor wiring.

Dimmer phasing is arranged 10 allow one low noise


simple horizontal rack to rack bussing. No rolary fan.
interconnection of feeder cable required.
Each dimmer neutral terminal is located in Lock lot restticling
an easily accessible area adjacent to lhe unauthaized access.
load terminal.

A label is provided on the inside of the door


and is adjacent to each dimmer for easy Label for easy
identi.fication of each circuit. i dcntif icatia n of ci tcuit s.

All power contacts are nickel-plated for


protection against wear and corrosion. All
signal contacts are gold-plated (minimum
oI 1 5 microns) for protection against wear
and corrosion.

Exlruded aluminum daat


with a naxinum swing
radius a14.5 inches.

Load and neuttal


lerminals accepl up lo
a #2 gauge wire.

I nte rla cking, pas iti ve g ui de s


lot dimmer modules,
both sides of reck

Ground lug.
Choose the control module that meets your needs

Comprised of completely digital


electronic circuitry including a high'
speed microprocessor. lndicator LED's
show that power is present and the
Viewpoint
Standard
system is functioning properly. If any
Conlro [iodLr e phase is missing or improperly wired,
LEC 2100 ihe indicator will blink. Each Control
[,4odule also has a user-selectable rack
number thumbwheel.
The Standard or Expanded Control
Modules act as the brain ol the
Viewpoint control system. The Expanded
Control Module allows lor remote
proqramminq and downloading of the
Viewpoint system features with a PC
AT/XT computer. Both the Standard and
Expanded Control Modules are equipped
with EEPROM memory storage lacility.

I Specif ications
CONTBOL MODULES
['IECHANICAL ELECTRICAL
A The control n]odlle sha I be a p ug in Ths Control lllodules shall have signal, VIEWPOINT CONTROL MODULE
assemb y containinq all the active airflow, and power ind cators visib e from (Standard or Expanded)
electronics in the rack and consisling of a the lront of the rack. The power lndicator
forrned steel chassis, two glass epoxy shall b ink if any phase is m ssing or A. The Viewpoint Control l\,4odule shall be
printed circuit boards, and a handle for incorrect y wired. A thLrrnbwheel sha I be
used ln the first rack of architectural
easy ilcert.on.nd 'emova Thp cl-assis accesslble from the front of the module to
sha I be ilnished n black polyurethane paint set the rack number. A test switch shall be systems in addition 10 the two ENR 96
with a si kscreened polycarbonate over ay provided to allow dimmers to be activated Control Modules. The module shall utilize
attached to the front of the module. Racks withcul a control system attached to the completely diqital electronic circuilry
uslng non plug-in control modules or rack. Three phase trimpots and a reset including a high speed microprocessor lor
electronics requ ring the removal of panels switch sha I also be accessible from the pelorminqal dimmerco'llrolcalculatiors
for servicing shall not be acceptable iront of the module. and ior handling externalserial
communicalions and a high speed A,/D
ELECTBICAL c. Each Conlrol Module shall have four 0-10V converter lor analyzing AC power
ENR 96 Control Module DC analog inputs which can be palched to
wavelorms. Control Modules utilizing
any of lhe 48 dimmers in either the lop or
A. Two ENR 96 Control lModules shall be used bottom half of lhe rack. A memory transfer complex analoq circuilry with greater than
'17" component tolerances shall nol be
in each ENR 96 rack The modules shall inpul shall be provided lo switch between
ut lize completely digltal electronic circuitry digital and analog control of these dimmers. acceptable. The expanded conttol module
includlng a high speed microprocessor for An integra adjuslable voliage power supply shall have provisions for an external pile-
performing all dimmer control calculalions for up to B external 10K ohrn on signal and shall automatically accepi
and for handllng external serial potentiometers shall also be provided. either LEEColortran prolocol (156K baud)
commr.rnicatlons and a high speed or DMX512 protocol (250K baud). Control
A/D converter ior analyzing AC power Each Control [,4odule shall have 48 swilches
N4odules requiring swilch selection of
waveforms. Control lvlodules Lltilizing for setling "dim" or "non-dim mode for the
comp ex analog circuitry with greater than various prolocols shall not be acceptable.
48 dimmers under its control. Racks
1% component to erances shall not be requiring specia non dim modules or with
acceptable. The control modules shall non-dim switches localed on the dimmer
automatica ly accept elther LEE Colortran shall not be acceptable.
protocol (156K baud) or DMX512 protocol
(250K baud). Contro N/odules requlring 240 Volt Conlrol lvlodules a so
swilch select on oi various protocols shall avai ab e. Conlacl factory lor
not be acceptab e. ordering inlormalion.
Specif ications
ELECTRICAL
Viewpoint Control Module
(Standard or Expanded) Racks shall be designed 10 allow for D. The rack shall contain a continuous duty
adjacent or back-lo-back mounting of low'noise fan wilh a maximum NC raling of
B. The Control l,,4odule shallhave signal, multiple racks. The rear section of the rack 43 to mai.ltain temperalures al proper
shall be utilized as a conlractor's wireway operating levels wilh all dimmers under full
airflow and power indicators visible from
with a minimum of 15" of wiring space load and ambient len'rperatures up to 40'C.
the front of the .ack. The power indicator The rack shall be provided with an aidlow
behind the dimmer module. Removable
shall blink if any phases are missing or conduit panels shall be provided on both sensor lo shJl ofl dimrne's in the rack
incorrectly wired. A thumbwheel shall be the top and botlom oi the rack for contractor should safe operating temperalures be
accessible from the front of the module 10 eniry with a minimum area of 140 in2. exceeded. A signal shall be provided to
set the pile-on otfset number. A test swilch operale a remote over-temperalure LED ij
shall be provided to allow dimmers to be B. The rack shall be conskucted 1o permit lhe aidlow sensor has been activdted
activaled withoul a control system insertion and removal of dimmers and Coolinq air shall be drawn through the
attached lo the rack. Three phase trimpots control modules wlthout the us-" of tools. dimmers and exhausled through the top of
Positive, interlocking guides shall be the rack. Since lhere is no airflow over any
and a reset swilch shall also be accessible
provided for precise alignment of the eleclrical connections in the dimmer, no
from the front of the module. A memory dimmers to the signal and power liitrat on sl^a., be required. Racks not usirg
card slot, read/w te switch, conilgure connectors in the rack. Dirnmer supports dimmer airflow channels and therefore
swilch, and PC interiace conneclor sha I be incorporaled into the sides of the requiring filters shall not be acceplable.
(expanded only) shall also be provided. rack, alLowing clear access to lhe power,
load, and reutral lerminals a1d lhe wrreway. E. The rack shall have 96 userselectable
Racks requiring disassernbly to access lhe control panic switches localed on the slgnal
termlnals and wireway or requiring the use distribution card in the rack. Racks wilhout a
ENR 96 DIMMER RACK of tools for replacemenl oi dimmers and panic ieature or using non-reprogrammable
conlrol modules shall not be acceptable. panic selection devices soch as clippable
MECHANICAL diodes shall not be acceplable.
C. The rack shall be designed to contain forly-
A. The ENR 96 dirnmer rack shallbe a free-
eight plug-in dimmer modules (eilher dual F
The rack shall have a lockable door with a
1.8/2.4/2.5kW or single 5.0/6.okw dimmers). maximum swing radlus oi 4-112" 10 prevenl
slanding dead front switchboard no larger
Each dual module position shall have a unauthorized access lo dimmer and control
than 80"H x 14"W x 19"D and shall house all
mating power bus, two load connectors, and modules. A blank labelshall be provided
specified equipment- lt shall be construcied
three gold-plated PC siqnal contacts and inside the door and dlrectly adjacenl lo each
of code gauge formed sreel and alurninum
shall be mechanically-keyed to accept only dimmer lor user idenliiicalion oi each circuit.
struclural members. All bus bars, lugs, and
the dimmer module specified ior that
lerminals shall be lin or nickel-pJated. All
position. The conlrol module positions shall G. Both load and neutral lerminals shall accept
exterior surfaces shall be finished in grey or
include appropriate contraclor conlrol signal up lo a #2 gauge wire. Neutral terminals
black polyurethane paint. The rack shall
terminal blocks and a signal distribution shall be located directly adjacent to load
weigh no more lhan 122 lbs. 1245lbs.
connector. terminals for ease ol conlraclor wiring.
including dimmers and conirol rnodules).
Provisions shall be made for optional lault
current proteclion devices (amp traps)
which may be installed and serviced from
the fronl oi the rack.

ELECTRICAL

A. The rack shall be designed to operale frorn


lEEColortran either 120 or 240 volts and either single or
three phase power. Removable panels shall
Ordering lnlormation be provided on the sides of the rack to
CatalogNo. Description allow simple rack to rack bussinq.
196-000 ENB 96, Conllgured Rack
196-001 ENF 96, 1.BkW2.4kW r 20V,
B. The rack shall be laclory tesled and conlrol
modules shallbe burned in at elevaled
Standard Theatrical/TV Rack
lemperalutes ior a rninimum of 4 hours.
196-002 ENB 96, Aux Rack
The rack shall be UL listed and CSA
196-003 ENB 96,240V Rack
Certified for 120V applications and shall
have an inlerrupting capacity of 10,000 A.
An inlerrupt'ng capacily o' 100.000 A is
available as an oplion.

Note: Specilication subject


to change without notice.

1015 Chestnut Sl., Burbank, CA 91506 9983 . (818) 843-1200 FAX. (818) 954-8520