Checklist for FiFi installations and startup report

When all items have been installed, tested OK and this report is completed and signed, please return it to JASON prior to commisioning via
fax: +47 32 20 45 60 or e-mail jason@jason.no. Once "Tested OK" and is signed by the Yard representative, the system is ready for commisioning.

Installation
Yard tested OK Time Time Extra hours
Item Item Installation (initials consumption consumption Extra hours accepted
no. description Item Work done OK (Date) startup tech) estimated actual for invoice (Yard repr.) Reason for extra hours
Travel Time return trip Three Days, return trips or overnight N/A
Installed piping connected and pressure tested. Align
1 Description: Pumps pump + gir before and after piping.
Comment:
Installed, alignment checked and signed by class.
2 Description: Gearboxes & Couplings Align pump & gir before and after piping.
Comment:
Installed, alignment checked and signed by class.
3 Description: Diesel engine / elmotor Align before and after piping.
Comment:

4 Description: Engine room other


Comment:

5 Description: Clutch / valve panel Installed, all cabling connected and cross checked.
Comment:

1. Innstallation completed, all cabling connected and


cross checked.
2. Power available and main engine running signals
6 Description: Control Cabinet and verified from engine supplier (if applicable).
Comment:
Installation completed, all cabling connected and
cross checked. End stop and hydraulic or electrical
7 Description: Monitors hoses / cables connected.
Comment:
All piping welded and stress-free connected to pump,
8 Description: Piping all pipes pressure tested.
Comment:
All piping installed.
Piping flushed for dirt before mounting nozzles.
9 Description: Nozzles for sprinklers All nozzles installed.
Comment:

10 Description: Fire hydrants Installed.


Comment:
All wiring to be done and power connected and cross
11 Description: Electric cabling checked.
Comment:

Jason Engineering A/S


Grønland 76-82, 3045 Drammen Phone: +47 32 20 45 50
Norway Fax: +47 32 20 45 60
www.jason.no Page 1 jason@jason.no
Installation
Yard tested OK Time Time Extra hours
Item Item Installation (initials consumption consumption Extra hours accepted
no. description Item Work done OK (Date) startup tech) estimated actual for invoice (Yard repr.) Reason for extra hours
All hydraulic piping to be done and power connected.
12 Description: Hydraulic systems Power pack has been flushed.

Comment:
Installed. El-power or air connected. Piping done.
Make sure no dirt inside valve. Valves move easy
13 Description: Valves manually.
Comment:

14 Fixed external cabling N/A

Fixed faulty gear, nozzle or other FiFi equipment N/A

Fixed external electrical components N/A

Portable joystick panel fixed on bridge

Oil filled on gear and hydraulics

Description: Other issues fixed

Comment:
15 Description: Other issues/report Hours extra Accepted by Yard (alt. comments)

Comment:

Signature, Yard representative: Date:

Signature technician:

FiFi startup terms and conditions

This document will follow the FiFi equipment from installtion through startup and must be returned to Jason as soon as possible after completed startup.
Before startup is performed, the following must be completed and made available to the startup technician. Time consumption as a result of failure to do so will be charged at the set hourly rate.
1. The technician must be allowed onto the ship without any delay upon arrival.
2. The technician must be allowed on shore immidiately at the end of the day or upon completion.
3. The FiFi system installation must be completed:
a. All external wirings must be completed and in working order.
b. All internal wirings must be completed and in working order.
c. All electrical connections must be completed and in working order.
d. All mechanical setup must be completed and in working order.
4. All items in the checklist above must be completed with "Yard installation OK (date)" by the installation crew on the Yard.
5. In addition, any delays caused by other circumstances onboard the ship or otherwise that is outside the FiFi startup technicians control may also be charged at the set hourly rate.
6. When "Time consumption actual" exceeds "Time consumption estimated" but is due to internal faults on the FiFi system, there should not be any "Extra hours for invoice".

Jason Engineering A/S


Grønland 76-82, 3045 Drammen Phone: +47 32 20 45 50
Norway Fax: +47 32 20 45 60
www.jason.no Page 2 jason@jason.no