EATS TAPES, WON'T EJECT (FOUND T-REEL TORQUE TO BE LOW)
SYMPTOMS
The customer complains that the unit eats tapes, or the tape won't eject.
Unit does not fail on the bench, and examination of the unit does not
reveal any absolute cause of the problem. However, the take-up reel
torque measures low (approx. 2 g/cm) and is therefore suspected to be
the cause of the customers' problems. New reels received from Kansas
City also measure low torque.
RESOLUTION
Disassemble the T/U reel and expand the spring so that the torque
increases to a more typical level (6 - 8 g/cm).
The info. for this FPR was submitted by Bill Steingraber of the N.E. RRC.
CCDTRV22
Subject
ERATIC MECH (MODE SYMPTOM); PIN 1 OF MODE SWITCH POOR SLDR.
SYMPTOMS
Unit had mode type problems. Tech discovered that pin 1 of the mode
switch had poor factory tinning.
RESOLUTION
Subject
NO COLOR IN E-E (FOUND IC706 DEFECTIVE)
SYMPTOMS
Unit had no color in E-E. Found no output from pin 20 of IC706 on the VC-
167 MCB.
RESOLUTION
Replace IC706.
CCDTRV22
Subject
NO CONTROL FROM I/R REMOTE (D307 MOUNTED BACKWARDS ON CF-42)
SYMPTOMS
RESOLUTION
CCDTRV22
Subject
NO LCD PICTURE (FOUND BAD SOLDER ON CN304 ON THE PD-67 MCB)
SYMPTOMS
RESOLUTION
Resolder CN304.
CCDTRV22
Subject
NO LCD PICTURE (FOUND CN303 PULLED LOOSE FROM PD-67 BOARD)
SYMPTOMS
The wire harness to CN303 on the PD-67 board was not drawn far enough
into the LCD cabinet at the time of manufacture. This caused the plug to
be pulled loose from CN303 when the customer rotated the LCD panel for
self-shooting. Have seen this problem sporadically in the past on other
models, but the problem is starting to be seen fairly frequently on this
model.
RESOLUTION
Pull the harness fully into the cabinet, reinsert connector.
SYMPTOMS
No part numbers listed in service manual for ref 221 (flex connector), and
ref 218 (CN98 board).
RESOLUTION
Part number A-7072-518-A is for the CN98 board. Part number 1-776-863-
11 is for the flex connector.
Subject
STATIC IN AUDIO DURING PLAYBACK (ALIGNED TAPE PATH)
SYMPTOMS
Customer complained that there was static in the audio during playback.
The static was heard when you tapped the side of the camera. Found
problem to be caused by mis-adjusted tape path.
RESOLUTION
SYMPTOMS
RESOLUTION
NO UNLOAD
SYMPTOMS
Unit would not unload. It was possible to load tape, problem caused by a
defective capstan motor. It would not run in reverse. All control logic to it
was correct.
RESOLUTION
SYMPTOMS
RESOLUTION
SYMPTOMS
Unit had no video in play but would show very distorted video in fwd or rev
scan.
RESOLUTION
Traced to leaky caps on dd80 board, replaced caps unit works fine.
Subject
Shaky Picture when Steady shot is on - Apply Grease to Ground Shaft.
SYMPTOMS
When Steady shot SW is ON, picture becomes shaky.
CAUSE
RESOLUTION
CCDTRV12
Subject
AUDIO CUTS OUT (FOUND EXTERNAL MIC JACK CONTACTS DIRTY)
SYMPTOMS
RESOLUTION
CCDTRV12
Subject
DISTORTED AUDIO (FOUND CORROSION ON MA BOARD)
SYMPTOMS
Unit had distorted E-E audio. Found corrosion on MA board on CN951 (no
evidence of liquid damage anywhere on camera.
RESOLUTION
Replaced MA board.
Subject
DOOR WON'T CLOSE (FOUND C-CLIP JAMMING CAPSTAN MOTOR)
SYMPTOMS
Door was stuck (wouldn't go down). Found problem to be caused by a C-
clip being stuck to the capstan motor, preventing its rotation. This C-clip is
used to to secure the right side of the LS assembly.
RESOLUTION
CCDTRV12
Subject
INTERMITTENT POWER (FOUND CORROSION ON CN102)
SYMPTOMS
RESOLUTION
CCDTRV12
Subject
INTERMITTENT SNOWY PIX RECORDED (RESOLDERED CN480 ON CF-42)
SYMPTOMS
RESOLUTION
CCDTRV12
Subject
IRIS REPETITIVELY OPENS AND CLOSES; FP221 BREAK IN CABLE
SYMPTOMS
The IRIS would open and close repetitively open and close.
RESOLUTION
Subject
LCD BACKLIGHT FLASHES WHEN POWER IS OFF (RESOLDERED IC400)
SYMPTOMS
Unit was flashing white light on the LCD panel when the power was off.
RESOLUTION
Resoldered IC400.
CCDTRV12
Subject
MECH JAMMED, WON'T FULLY EJECT TAPE (MODE SWITCH MISALIGNED)
SYMPTOMS
Would not eject tape. LS assembly would move, but would not open
carriage. Found mode switch misaligned.
RESOLUTION
CCDTRV12
Subject
MECHANSIM WON'T LOAD COMPLETELY (CASSETTE DOOR HAD BURR)
SYMPTOMS
RESOLUTION
Removed a plastic burr from the cassette door (ref. 3) which was
preventing complete loading.
CCDTRV12
Subject
NO EVF PICTURE (FOUND CN901 NOT FULLY SEATED ON VF-102 MCB)
SYMPTOMS
Complaint was dead unit when in fact the EVF had no picture. Found VF-
102 board CN901 was not fully seated.
RESOLUTION
CCDTRV12
Subject
NO PLAYBACK VIDEO (FOUND DRUM ASSEMBLY BAD).
SYMPTOMS
RESOLUTION
CCDTRV12, CCDTRV22
Subject
PART NUMBERS FOR CN98 BOARD & FFC204 FLEX BOARD
SYMPTOMS
No part numbers listed in service manual for ref 221 (flex connector), and
ref 218 (CN98 board).
RESOLUTION
Part number A-7072-518-A is for the CN98 board. Part number 1-776-863-
11 is for the flex connector
CCDTRV12
Subject
TAPE GUIDES DON'T LOAD (FOUND REF. 820 BENT, REF. 822 GONE)
SYMPTOMS
Tape guides would not load. Found problem to be caused by the slider
(ref. 820) being bent, and spring (ref. 822) missing.
RESOLUTION
Replaced parts.
CCDTRV12
Subject
NO VIDEO THORUGH LCD
SYMPTOMS
RESOLUTION
111398611 C515QP
CCDTRV10E, CCDTRV12
Subject
CABINET L ASSY INCORRECT - CORRECT PN IS X-394-705-61
SYMPTOMS
CCDTRV12
Subject
NO CAMERA OPERATION - REPL TIMING GENERATOR IC702
SYMPTOMS
There was no camera video. VCR section worked OK. There was no
output from the CCD. The CCD was initially changed because it appeared
that all the timing signals were present, etc. However, the problem turned
out to be the Timing Generator, IC702. All timing signals were present, but
not correct.
RESOLUTION
Subject
NO VID IN CAM MODE IRIS STUCK CLOSED - REMOVED OIL FROM IRIS
SYMPTOMS
Verified proper iris drive net and positive to iris motor, found normal.
RESOLUTION
Disassembled lens block, found oil on iris blades and back portion of
master lens, removed oil. Reassembled and confirmed proper operation.
CCDTRV112
Subject
SMEARED EE - VIDEO; <EVF FLEX DAMAGED BY THE CCD IC PINS>
SYMPTOMS
Recurring prob with this model. The evf ribbon is routed in a large loop
and when unit is assembled the ribbon rubs on the ccd imager pins. These
pins being very sharp will rub thru the foil after a period of time when
raising and lowering EVF. Symptoms is intermittent smeared EE video. If
you squeeze the case or disassemble the cabinet, the problem clears up.
RESOLUTION
Reroute cable and tape against cabinet half allowing for some travel.
CCDTRV112
Subject
INTERMITTENT REEL ERRORS; ADD TAPE TO LS CHASSIS FLEX
SYMPTOMS
Intermittent reel erros. Problem often caused by the ribbon cable on the ls
chassis beng shorted out by the cassette compartment when it is closed.
The problem occurs in the corner where the ribbon cable takes a 90
degree turn right by S002/cc lock.
RESOLUTION
Add a small piece of electrical tape over the flex cable. This wil prevent it
from being shorted out. If ribbon cable is severed it must be replaced.
Many techs try to resolve this intermittent problem by changing the senors,
goosenect, reel talbe, etc. If they change the ls assembly the problem
may reoccur in a short time if the ribbon is not