You are on page 1of 77

Estudio de dilución del

vertido de aguas
residuales procedente del
futuro emisario de
Sagunto

Centre Internacional d’Investigació de


Recursos Costaners (CIIRC)

Barcelona, Octubre 2015


Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

Tabla de contenido

1.- Introducción _______________________________________________________ 1


2.- Zona de estudio_____________________________________________________ 1
3.- Modelo numérico ___________________________________________________ 3
4.- Simulaciones numéricas ______________________________________________ 4
4.1.- Características del emisario y difusores ___________________________________________ 4
4.2.- Características del medio receptor _______________________________________________ 4
4.3.- Características del efluente. Hipótesis de vertidos a través del emisario _________________ 5

5.- Resultados _________________________________________________________ 7


5.1.- Caso S1-0 ___________________________________________________________________ 8
5.2.- Caso S1-0b _________________________________________________________________ 10
5.2.- Caso S1-3 __________________________________________________________________ 11
5.2.- Caso S2-0 __________________________________________________________________ 14
5.2.- Caso S2-0b _________________________________________________________________ 16
5.3.- Caso S2-3 __________________________________________________________________ 17

6.- Conclusiones ______________________________________________________ 20


APÉNDICE A – RESULTADOS DE CORMIX PARA EL CASO S0-1 __________________ 22
APÉNDICE B – RESULTADOS DE CORMIX PARA EL CASO S0-1b _________________ 30
APÉNDICE C – RESULTADOS DE CORMIX PARA EL CASO S0-3 __________________ 37
APÉNDICE D – RESULTADOS DE CORMIX PARA EL CASO S2-0 __________________ 47
APÉNDICE E – RESULTADOS DE CORMIX PARA EL CASO S2-0b _________________ 55
APÉNDICE F – RESULTADOS DE CORMIX PARA EL CASO S2-3 __________________ 63
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

1.- Introducción

En el presente estudio se evalúa la dilución del efluente descargado a través del emisario
submarino proyectado frente al puerto de Sagunto, y que vierte las aguas combinadas
procedentes de distintas fuentes. Los objetivos principales del estudio son:

i) Simular la evolución del vertido procedente de un emisario submarino en la


costa de Sagunto, analizando sus posibles implicaciones sobre el medio, bajo
distintas condiciones ambientales y de vertido.
ii) Proponer, en caso de afectación ambiental, mejoras al diseño del emisario con
la finalidad de aumentar la dilución del vertido.

Los análisis realizados en este estudio se han basado en información proporcionada por
GLOBAL Consulting Engineering, así como en datos extraídos de estudios previos. En
concreto, se han utilizado el “Estudio de impacto ambiental del proyecto del refuerzo del
sistema de abastecimiento del área metropolitana de Valencia y el Camp de Morvedre.
Desaladora de Sagunto (Valencia)” y el “Análisis ambiental del emisario para aguas pluviales
e industriales de Sagunto”.

En la Instrucción para el proyecto de conducciones de vertido desde la tierra al mar (orden de


13 de Julio de 1993) se proporcionan una serie de ecuaciones para estimar la dilución de un
efluente para casos relativamente sencillos, en función de la relación existente entre la
profundidad de vertido (H) y la separación entre difusores (s), y que determina la interacción o
no entre distintos penachos. Para s/H > 0.20 se asume que no existe esta interacción en el campo
cercano, mientras que para s/H < 0.03 sí puede existir interacción entre penachos antes de
alcanzar la zona de mezcla. En el presente caso, sin embargo, dicha relación es cercana a 1,
queda por tanto fuera del ámbito de aplicación de estas ecuaciones, y es necesario recurrir al
modelado numérico.

2.- Zona de estudio

Sagunto se encuentra situado en la comarca de Camp de Morvedre (figura 1), en el extremo NE


de la provincia de Valencia, entre los 39º37’ y 39º 48’ N de latitud y los 0º11’ y 0º19’ O de
longitud. La ciudad tiene dos núcleos de población (Sagunto ciudad, o núcleo histórico, y Puerto
de Sagunto) con características propias, separados unos 5 km y con una evolución poblacional
que ha estado ligada a los acontecimientos socioeconómicos que llevaron a la creación del gran
núcleo industrial en la zona del Puerto. El puerto propiamente dicho limita al norte con la playa
del Puerto de Sagunto, y al sur con el Grau Vell.

La zona costera de Sagunto tiene una configuración batimétrica dominada por las características
del Óvalo de Valencia, unidad morfodinámica que se extiende desde el Delta del Ebro hasta el
Cabo de San Antonio, y en cuya parte central se encuentra. La zona interior del puerto tiene
profundidades de entre 10 y 20 metros, mientras que en la zona exterior la profundidad aumenta
suavemente con la distancia a la costa.

1
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

La hidrodinámica de la zona está fuertemente influenciada por la corriente general del


Mediterráneo Occidental, caracterizada por flujos sobre la plataforma continental en dirección
paralela a la costa y, generalmente, en dirección sur. Esta corriente general puede verse
modificada por la influencia de otros mecanismos forzadores, como pueden ser el viento, las
mareas, o la descarga de agua dulce de origen fluvial. No obstante, en esta zona los aportes
fluviales son insignificantes, y el carácter micromareal de la costa levantina (con amplitudes de
marea del orden de 10-15 cm) implica que las corrientes mareales (de unos pocos cm/s) son
pequeñas en relación a la magnitud de la corriente general.

Figura 1: Zona de estudio.


Por otra parte, los vientos en la zona muestran una gran variabilidad en cuanto a dirección, con
porcentajes de ocurrencia parecidos para vientos del NNE-NE, SE-SSE, y O-OSO, si bien estos
últimos tienden a ser los más intensos, con velocidades que ocasionalmente pueden superar los
14 m/s. En cualquier caso, las velocidades típicas suelen ser inferiores a los 6 m/s (figura 2). Las
simulaciones numéricas de la circulación inducida por viento en las cercanías del Puerto de
Sagunto presentadas en el “Análisis ambiental del emisario para aguas pluviales e industriales
de Sagunto” (IH Cantabria, 2010) muestran velocidades de corriente típicas del orden de 2-6
cm/s para todos los casos de viento considerados en ese estudio.

Figura 2: Rosa de vientos e histograma de frecuencia de velocidades del viento para la costa
litoral valenciana, durante el periodo 2005-2015, a partir de datos medidos en la boya de
Valencia de la Red Exterior de Puertos del Estado.

2
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

3.- Modelo numérico

La herramienta numérica utilizada en este estudio es CORMIX, un sistema que combina un


modelo para simular la zona de mezcla resultante de un vertido puntual continuo con un sistema
de apoyo a la toma de decisiones relacionadas con la evaluación de impacto ambiental asociado
a este tipo de vertidos.

El modelo de simulación está basado en una aproximación integral al problema de la dispersión.


En esta aproximación, se describe la evolución de una característica del vertido (en este caso, el
eje del penacho) a partir de un conjunto de ecuaciones basadas en experimentos, y
posteriormente se analiza la distribución radial de concentraciones suponiendo que sigue una
distribución predeterminada. En el caso de penachos procedentes de descargas submarinas, se
suele asumir una distribución radial gaussiana en la zona de campo cercano, y una distribución
tipo “sombrero de copa” para el campo lejano.

CORMIX incluye un sistema de clasificación hidrodinámica de los vertidos en función de


diferentes escalas características de longitud propias de cada descarga, y que tienen en cuenta
variables tales como el momentum y la flotabilidad del vertido, la velocidad del medio receptor,
o el ángulo de la descarga respecto a la horizontal y respecto a la corriente ambiental, entre
otros. Este tipo de clasificación permite evaluar de forma rápida el comportamiento general de
un vertido en relación al medio receptor. La figura 3 muestra un ejemplo de clasificación de
penachos con flotabilidad positiva en un medio uniforme.

Figura 3: Esquema de clasificación vertidos con flotabilidad positiva en un


medio uniforme, según el modelo CORMIX.

Los modelos de dispersión integrales, basados en el comportamiento medio de un vertido


obtenido a partir de un número de experimentos, reproducen la evolución de descargas bajo
condiciones relativamente simples tanto del medio como del emisario (e.g., corrientes
uniformes y constantes, batimetrías sencillas, vertidos constantes, etc.). No obstante, por su
rapidez de ejecución y facilidad de uso constituyen una herramienta ampliamente utilizada para
determinar el comportamiento de descargas, tanto submarinas como superficiales, en la zona
más cercana al punto de vertido.

3
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

4.- Simulaciones numéricas

4.1.- Características del emisario y difusores

El emisario proyectado consiste en una conducción desde tierra hacia el mar, apoyada sobre el
fondo, con un diámetro de 4 m, que se divide en 4 ramales de 1,4 m de diámetro. Los dos
primeros ramales se encuentran a una distancia de unos 3,5 km de la costa (aproximadamente a
1,7 km de las estructuras exteriores del Puerto de Sagunto) y a una profundidad de 28,6 m, y se
extienden perpendicularmente a la conducción principal en ambas direcciones. Los otros dos
ramales, de configuración similar, se encuentran a una distancia de 100 m hacia mar adentro
(figura 4).

25 m
100 m Difusores

Figura 4: Configuración del emisario y de los difusores

Sobre estos ramales se alzan 30 difusores (8 en cada uno de los ramales más cercanos a la costa,
y 7 en cada ramal exterior) de 2 m de largo e inclinados 60º respecto a la horizontal. La altura
de los puntos de descarga sobre el fondo marino es, por tanto, de aproximadamente 3,1 m. Los
difusores tienen un diámetro interno de 0,3 m, y están separados 25 m entre ellos. Se asume que
la dirección de descarga es perpendicular a los ramales, con el fin de minimizar las
probabilidades de interacción entre los vertidos de los distintos difusores y maximizar, por
tanto, su dilución.

4.2.- Características del medio receptor

A partir de los datos proporcionados referentes a la caracterización del medio en la zona exterior
del Puerto de Sagunto, se asume un cuerpo de agua receptor no estratificado, con perfiles de
salinidad y de temperatura uniformes, y con valores de 37.20 y 19.5ºC, respectivamente. Con
estos parámetros de temperatura y salinidad, la densidad resultante del medio receptor es de
1027,28 kg/m3.

En lo referente a las características meteo-hidrodinámicas, se supondrán dos escenarios


distintos, con vientos nulos y corrientes marinas de 0 m/s y de 0.3 m/s, paralelas a la costa (y
perpendiculares al vertido) y uniformes a lo largo de la columna de agua. El primer valor
describe el peor caso posible, puesto que la presencia de una corriente cualquiera aumentará la
dilución, y el segundo corresponde a la velocidad máxima del rango de corrientes especificado
en el “Estudio de impacto ambiental del proyecto del refuerzo del sistema de abastecimiento del
área metropolitana de Valencia y el Camp de Morvedre. Desaladora de Sagunto (Valencia)”.

4
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

4.3.- Características del efluente. Hipótesis de vertidos a través del emisario

Para las simulaciones numéricas se toman dos hipótesis de vertido en función de las distintas
fuentes susceptibles de aportar vertidos al emisario. En este sentido, se puede considerar que
hay 9 fuentes potenciales de aguas residuales, cuyos caudales estimados se muestran en la tabla
1:

Fuente Caudal estimado (l/s)


Fertiberia 344,88
EDAR 405,13
Arcelor Mittal 17,12
Unión Fenosa 619,65
Planta desaladora 218,00
ZUVAMESA 250,00
Piscifactoría 150,00
Camí al Mar 95,63
Tratamientos 11,25
TOTAL 2112,27
Tabla 1: Estimación de caudales aportados
por las distintas fuentes al vertido del
emisario de Sagunto
De todas estas fuentes, únicamente tres (ZUVAMESA, Planta desaladora y Tratamientos)
generan aguas residuales con salinidad no nula. Se han tomado valores de conductividad de
250,00 S/cm, 90,53 S/cm y 80,00 S/cm, respectivamente, que corresponden a salinidades de
167,5 ppm, 59,2 ppm y 34.11 ppm. Para la conversión de conductividad a salinidad se ha
utilizado un factor de conversión de 0.67 para el caso de aguas consideradas “limpias”
(Desaladora y ZUVAMESA) y de 0.74 para aguas de origen industrial con concentraciones
elevadas de sólidos en suspensión (Tratamientos).

Con estos datos, se definen dos situaciones de vertido:

a) Situación 1, en la cual todas las fuentes vierten a través del emisario submarino. En este
caso, el caudal total vertido es de Q = 2112,27 l/s (2,1123 m3/s), y la salinidad final del
efluente viene dada por

donde St, Sd y Sz son las salinidades de los vertidos procedentes de Tratamientos, la


planta desaladora y ZUVAMESA, y Qt, Qd y Qz son los respectivos caudales. Hay que
tener en cuenta que las aguas procedentes de la planta desaladora y de Unión Fenosa se
mezclan antes de alcanzar el emisario, con lo cual Qd = 838,27 l/s, y la salinidad Sd es la
resultante de la combinación de ambos efluentes (Sd = 50,91 S/cm = 34,11 ppm).
Para esta situación, la salinidad final del vertido es de 33,68 ppm. Asumiendo una
temperatura de vertido de 18,5 ºC , la densidad resultante del efluente es de 1024,166
kg/m3.

b) Situación 2, en la cual todas las fuentes vierten a través del emisario submarino,
EXCEPTO la planta desaladora y Unión Fenosa. Para este escenario, el caudal vertido

5
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

es inferior (Q = 1274,00 l/s = 1,2740 m3/s) y la salinidad, obtenida aplicando la


ecuación anterior con Qd = 0, es ligeramente menor (S = 33,40 ppm). Bajo estas
condiciones, la densidad final del efluente es de 1023,952 kg/m3.

La concentración de otras substancias en el vertido varía en función del escenario considerado,


y se resume en la tabla 2.

Substancia Situación 1 Situación 2


Fósforo total (mg/l) 5,92 9,81
S. en S. (mg/l) 133,06 197,59
TOC (mg/l C) 8,71 14,44
Fósforo total (mg/l) 0,03 0,05
Nitrógeno amoniacal (mg/l) 10,06 16,68
Nitrógeno total (mg/l) 6,77 1,35
Aceites y grasas (mg/l) 4,08 0,18
Hierro (mg/l) 0,05 0,09
Níquel (mg/l) 0,01 0,02
Cobre (mg/l) 0,02 0,03
Cromo total (mg/l) 0,02 0,03
Sulfuros (mg/l) 0,03 0,05
Cianuros (mg/l) 0,00 0,00
Zinc (mg/l) 0,27 0,45
Cadmio (mg/l) 0,00 0,00
Plomo (mg/l) 0,01 0,01
Hg (mg/l) 0,00 0,00
E. coli (ufc/100 ml) 3.968,57 0,00
Enterococos int. (ufc/100 ml) 793,71 0,00
Tabla 2: Concentración de substancias en el efluente vertido, para
los dos escenarios de descarga considerados.

En las tablas 3, 4 y 5 se resumen los parámetros utilizados para las distintas simulaciones,
basados en la descripción anterior del medio, del emisario y del efluente. En la nomenclatura
utilizada, S1 y S2 corresponden a las dos situaciones de vertido definidas previamente, y -0 y -3
corresponden a las dos magnitudes de velocidad ambiental consideradas (0,0 m/s y 0,3 m/s,
respectivamente).

Las simulaciones se han realizado considerando únicamente el ramal más cercano a la costa ya
que, al estar situado a menor profundidad y siendo el resto de condiciones iguales, dará lugar a
una menor dilución del efluente al final de la zona de mezcla. La configuración del emisario y
las características hidrodinámicas del medio (corrientes paralelas a la costa y a los ramales)
hacen improbable que haya interacción entre los penachos procedentes de los ramales más
cercanos a la costa con aquellos generados por los ramales más lejanos.

Por otra parte, la simulación de los casos S1-0 y S2-0 indica que no se produce mezcla entre los
penachos de efluente procedentes de difusores contiguos antes de que éstos lleguen a la
superficie, y que el comportamiento de cada penacho es independiente de los demás. Con el

6
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

objetivo de verificar esta hipótesis, se ha procedido a simular la evolución del vertido


procedente de un único difusor (caso S1-0b).

Caso de simulación
Parámetro
S1-0 S1-0b S1-3 S2-0 S2-3
Temperatura del medio (ºC) 19,5
Salinidad del medio (ppm) 37,2
Densidad del medio (kg/m3) 1027,28
Velocidad del medio (m/s) 0,0 0,3 0,0 0,3
Tabla 3: Parámetros del medio receptor utilizados en el modelado numérico.

Caso de simulación
Parámetro
S1-0 S1-0b S1-3 S2-0 S2-3
Temperatura del vertido (ºC) 18,5
Salinidad del vertido (ppm) 33,68 33,40
Densidad del vertido (kg/m3) 1024,166 1023,952
Caudal total (m3/s) 2,112 1,274
Caudal por difusor (m3/s) 0,0704 0,0425
Tabla 4: Parámetros del efluente utilizados en el modelado numérico.

Caso de simulación
Parámetro
S1-0 S10-b S1-3 S2-0 S2-3
Profundidad de descarga (m) 28,6
Altura sobre el fondo (m) 3,1
Diámetro (m) 0,3
Ángulo vertical (º) 60
Ángulo respecto a corrientes
90
(º)
Ángulo respecto al ramal (º) 90
Separación entre difusores (m) 25
Tabla 5: Parámetros del punto de descarga utilizados en el modelado
numérico.

5.- Resultados

Las características del efluente y los valores de temperatura y salinidad del agua receptora
indican que, para todos los escenarios considerados, el vertido tiene flotabilidad positiva, con lo
cual no se prevé que haya afectación del fondo. En la figura 5 (izquierda), se muestra un
esquema general del comportamiento de un chorro con flotabilidad positiva; en esta figura, D es
el diámetro de la boca de descarga, h0 es la altura del vertido, Uo, 0 y c0 son la velocidad,
flotabilidad y concentración inicial del efluente, respectivamente, y ua y a son la velocidad y
densidad del medio receptor.

7
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

Figura 5: Izq.) Esquema general del comportamiento de un chorro con densidad


inferior a la del medio. Der.) Esquema de funcionamiento de un emisario submarino
tipo.

El objetivo de este estudio es evaluar la dilución del efluente en la zona más cercana a la
descarga (campo cercano o zona de dilución inicial). En esta zona (figura 5, derecha), el
efluente se diluye con el agua del medio de forma relativamente rápida, debido a su momentum
inicial (i.e., su velocidad de vertido) y a la mezcla inducida por la flotabilidad del vertido. En el
caso de vertidos de flotabilidad positiva, la zona de dilución inicial termina cuando el penacho
llega hasta la superficie, o alcanza una profundidad a la cual su densidad se iguala a la del
medio (atrapamiento en profundidad). En general, los criterios de calidad de agua aplicables a
cada tipo de vertido requieren el cumplimiento de ciertos requisitos en el borde de la zona de
dilución inicial, permitiéndose que se superen los umbrales dentro de la misma.

Fuera de esta región inicial, el proceso de mezcla del vertido con el agua del medio receptor
proseguirá a un ritmo determinado principalmente por mecanismos advectivos y turbulentos,
característicos del medio e independientes de los parámetros del vertido (campo lejano).

Si bien la simulación del comportamiento de un vertido en su campo cercano puede hacerse de


forma relativamente simple, el modelado preciso del campo lejano requiere una información
más detallada del medio receptor (e.g., batimetría de la zona, campos realistas de corrientes y
viento, …) y herramientas de análisis más sofisticadas (e.g., modelos físicos, o modelos
numéricos 3D).

5.1.- Caso S1-0

Para este caso de simulación, el penacho se clasifica como de tipo MU1V dentro de la
clasificación hidrodinámica de CORMIX. Este tipo de vertido tiene una configuración de
descarga hidrodinámicamente estable, en la cual la intensidad de descarga (i.e., el flujo de
momentum inicial) es baja en relación con la profundidad del vertido y con el efecto
estabilizador del flujo de flotabilidad.

8
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

Según la predicción del modelo, el penacho llega a la superficie a una distancia de


aproximadamente 5,5 m del eje del ramal del emisario, ocupando los 2,4 m más superficiales de
la columna de agua (figura 6). Esta distancia, y la separación entre ramales, asegura que no hay
interacción entre los penachos de los distintos ramales. La dilución alcanzada en el centro del
penacho en este punto es de 34,1 (figura 7), lo que implica un déficit de salinidad respecto al
medio de 0,103 ppm (figura 8).

Figura 6: Trayectoria vertical del penacho del efluente para el caso S1-0.

Figura 7: Evolución de la dilución del penacho en función de la profundidad,


para el caso S1-0.

Debido a la ausencia de corrientes, no hay transporte advectivo del efluente, y cualquier


reducción posterior del déficit de salinidad será debida únicamente a efectos de la mezcla
turbulenta.

9
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

En la figura 9 se muestra la evolución de la dilución y de la concentración (déficit de salinidad)


en función de la distancia al punto de vertido. La salida del modelo CORMIX para este caso se
presenta en el apéndice A.

Figura 8: Déficit de salinidad del penacho en función de la profundidad, para


el caso S1-0

Figura 9: Dilución (línea continua) y déficit de salinidad (línea discontinua)


del penacho en función de la distancia a la fuente, para el caso S1-0

5.2.- Caso S1-0b

El caso S1-0b difiere del anterior en que únicamente se considera un difusor. El objetivo es
verificar los resultados obtenidos para el caso S1-0, en el cual no se prevé interacción entre los
penachos procedentes de difusores contiguos. La salida del modelo numérico se muestra en el
apéndice B. Como puede comprobarse, la evolución y características de este penacho único
coinciden exactamente con los resultados correspondientes al caso S1-0.

10
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

5.2.- Caso S1-3

En este caso los parámetros de descarga son idénticos a los del caso S1-0, pero con el añadido
de una corriente ambiental, paralela al eje del ramal (i.e., perpendicular a la dirección de
vertido), de 0,3 m/s.

La clasificación del flujo resultante, según las predicciones del modelo numérico, es M1UH.
Este penacho, hidrodinámicamente estable, se caracteriza por una primera fase en la que el
vertido está dominado por el momentum inicial, seguida por otra en la cual predominan los
efectos de flotabilidad y la deflexión inducida por la corriente ambiental. Debido a esta
deflexión, los penachos procedentes de difusores contiguos entran en contacto entre ellos a una
cierta distancia de su origen, dando lugar a un penacho único que alcanza su altura terminal con
una distribución de concentración lateral y vertical aproximadamente uniforme. En esta zona, la
pluma de efluente es transportada por las corrientes advectivas.

Con la configuración actual, la fusión de penachos individuales se produce a una profundidad de


19,5 m (9,1 m por encima del fondo, y 6 m por encima de los difusores). La pluma resultante
alcanza la superficie a una distancia de 244 m aguas abajo del centro del emisario, con una
dilución en su eje de 1064,0 (figuras 11 y 12), correspondiente a un déficit de salinidad respecto
a la ambiental de 0,003 ppm (figura 10). Al final de la zona de mezcla, a 430 m aguas abajo del
centro del emisario, la dilución es de 2294,7, y la salinidad del penacho es únicamente 0.001
ppm inferior a la del medio (figura 14). A partir de este momento, se produce transporte
longitudinal por corrientes y expansión lateral por difusión. Según los resultados del modelo
numérico, el ancho de la pluma en esta zona aumenta desde los 300 hasta los 450 m (figura 15)
si bien, en cuanto a salinidad, esta es prácticamente indistinguible del medio.

Los resultados del modelo CORMIX para este caso se muestran en el apéndice C.

Figura 10: Déficit de salinidad del penacho en función de la profundidad, para


el caso S1-3.

11
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

Figura 11: Trayectoria vertical del penacho del efluente para el caso S1-3.

Figura 12: Evolución de la dilución del penacho en función de la profundidad,


para el caso S1-3.

12
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

Figura 13: Dilución (línea continua) y déficit de salinidad (línea discontinua)


del penacho en función de la distancia a la fuente, para el caso S1-3.

Figura 14: Dilución (línea continua) y déficit de salinidad (línea discontinua)


del penacho en función de la distancia aguas abajo a la fuente, para el caso S1-
3, en campo lejano.

13
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

Figura 15: Trayectoria y tamaño del penacho en superficie en función del


tiempo, para el caso S1-3, en campo lejano.

5.2.- Caso S2-0

El caso S2-0 corresponde a un efluente con una diferencia de densidad respecto al medio menor
que en el caso S1-0. Si bien la mezcla inicial será también menor, el penacho tarda más tiempo
en alcanzar el final de la zona de dilución inicial (89 s), con lo cual la dilución en este punto es
mayor.

Para este caso de simulación, y de forma equivalente al caso S1-0, el penacho se clasifica como
de tipo MU1V dentro de la clasificación hidrodinámica de CORMIX. Este tipo de vertido tiene
una configuración de descarga hidrodinámicamente estable, en la cual la intensidad de descarga
(i.e., el flujo de momentum inicial) es baja en relación con la profundidad del vertido y con el
efecto estabilizador del flujo de flotabilidad.

Según la predicción del modelo, el penacho llega a la superficie a una distancia de


aproximadamente 3,9 m del eje del ramal del emisario, ocupando los 2,4 m más superficiales de
la columna de agua (figura 16). Esta distancia, y la separación entre ramales, asegura que no hay
interacción entre los penachos de los distintos ramales. La dilución alcanzada en el centro del
penacho en este punto es de 46,5 (figura 17), lo que implica un déficit de salinidad respecto al
medio de 0,082 ppm (figura 18).

Debido a la ausencia de corrientes, no hay transporte advectivo del efluente, y cualquier


reducción posterior del déficit de salinidad será debida únicamente a efectos de la mezcla
turbulenta.

En la figura 19 se muestra la evolución de la dilución y de la concentración (déficit de salinidad)


en función de la distancia al punto de vertido. El apéndice D presenta los resultados del modelo.

14
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

Figura 16: Trayectoria vertical del penacho del efluente para el caso S2-0.

Figura 17: Evolución de la dilución del penacho en función de la profundidad,


para el caso S2-0.

15
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

Figura 18: Déficit de salinidad del penacho en función de la profundidad, para


el caso S2-0

Figura 19: Dilución (línea continua) y déficit de salinidad (línea discontinua)


del penacho en función de la distancia a la fuente, para el caso S2-0

5.2.- Caso S2-0b

El caso S2-0b difiere del anterior en que únicamente se considera un difusor. El objetivo es
verificar los resultados obtenidos para el caso S2-0, en el cual no se prevé interacción entre los
penachos procedentes de difusores contiguos. La salida del modelo numérico se muestra en el
apéndice E. Como puede comprobarse, la evolución y características de este penacho único
coinciden exactamente con los resultados correspondientes al caso S2-0.

16
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

5.3.- Caso S2-3

En este caso los parámetros de descarga son idénticos a los del caso S2-0, pero con el añadido
de una corriente ambiental, paralela al eje del ramal (i.e., perpendicular a la dirección de
vertido), de 0,3 m/s.

La clasificación del flujo resultante, según las predicciones del modelo numérico, es M1UH.
Este penacho, hidrodinámicamente estable, se caracteriza por una primera fase en la que el
vertido está dominado por el momentum inicial, seguida por otra en la cual predominan los
efectos de flotabilidad y la deflexión inducida por la corriente ambiental. Debido a esta
deflexión, los penachos procedentes de difusores contiguos entran en contacto entre ellos a una
cierta distancia de su origen, dando lugar a un penacho único que alcanza su altura terminal con
una distribución de concentración lateral y vertical aproximadamente uniforme. En esta zona, la
pluma de efluente es transportada por las corrientes advectivas.

Con la configuración actual, la fusión de penachos individuales se produce a una profundidad de


20,5 m (8,1 m por encima del fondo, y 5 m por encima de los difusores; figura 20).

Figura 20: Trayectoria vertical del penacho del efluente para el caso S2-3.

La pluma resultante alcanza la superficie a una distancia de 320 m aguas abajo del centro del
emisario, con una dilución en su eje de 1823,7 (figuras 20 y 21), correspondiente a un déficit de
salinidad respecto a la ambiental de 0,002 ppm (figura 22). Al final de la zona de mezcla, a 500
m aguas abajo del centro del emisario, la dilución es de 3800,9, y la salinidad es virtualmente
idéntica a la del medio (figura 24). A partir de este momento, se produce transporte longitudinal
por corrientes y expansión lateral por difusión. Según los resultados del modelo numérico, el
ancho de la pluma en esta zona es del orden de los 350-400 m (figura 25) si bien, en cuanto a
salinidad, esta es indistinguible del medio.

Los resultados del modelo CORMIX para este caso se presentan en el apéndice F.

17
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

Figura 21: Evolución de la dilución del penacho en función de la profundidad,


para el caso S2-3.

Figura 22: Déficit de salinidad del penacho en función de la profundidad, para


el caso S2-3

18
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

Figura 23: Dilución (línea continua) y déficit de salinidad (línea discontinua)


del penacho en función de la distancia a la fuente, para el caso S2-3.

Figura 24: Dilución (línea continua) y déficit de salinidad (línea discontinua)


del penacho en función de la distancia a la fuente a la fuente, para el caso S2-3,
en campo lejano.

19
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

Figura 25: Trayectoria y tamaño del penacho en superficie en función del


tiempo, para el caso S2-3, en campo lejano.

6.- Conclusiones

Se han realizado simulaciones numéricas del vertido procedente de un emisario submarino


frente a la costa de Sagunto, a una profundidad de 28,6 m, utilizando el sistema de predicción
CORMIX. Se han considerado dos situaciones de vertido y dos escenarios hidrodinámicos
diferentes. Las situaciones de vertido incluyen diferentes caudales de descarga y efluentes con
distintas densidades y concentraciones de substancias; los escenarios hidrodinámicos
corresponden a una condición de velocidad nula de las corrientes (“peor escenario posible”) y a
unas corrientes de 0,3 m/s paralelas a la costa (corrientes máximas típicas, según el “Estudio de
impacto ambiental del proyecto del refuerzo del sistema de abastecimiento del área
metropolitana de Valencia y el Camp de Morvedre. Desaladora de Sagunto (Valencia)).

En la tabla 6 se muestran las concentraciones esperadas de las distintas substancias presentes en


el efluente para cada uno de los casos simulados, considerando los valores iniciales en la
descarga, y las diluciones predichas por el modelo numérico. En algunos casos, es probable que
las concentraciones reales sean menores a las tabuladas, debido a la acción de otros procesos de
dilución no físicos que no se han tenido en cuenta en la simulación (e.g., decaimiento de
microorganismos debido a la hostilidad del medio receptor). Para todos los casos, los valores de
concentración obtenidos a partir del modelado numérico al final de la zona de mezcla se
encuentran dentro de los rangos permitidos por los criterios de calidad ambiental definidos en el
RD-Ley 345/1993 del 5 de Marzo, que establece las normas de calidad aplicables a aguas
destinadas al cultivo de moluscos y otros invertebrados marinos (transposición de la Directiva
2006/113/CE del 12 de Diciembre) y en el RD 1341/2007 del 11 de Octubre, que transpone al
ámbito español la directiva europea 2006/7/CE del 15 de Febrero, relativa a la calidad de las
aguas de baño. Adicionalmente, estos valores se ajustan también a los criterios propuestos en su
momento por el CEDEX basados en los parámetros de otros organismos internacionales (OMS
y USEPA).

20
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

Substancia Caso S1-0 Caso S1-3 Caso S2-0 Caso S2-3


Fósforo total (mg/l) 0,17 0,01 0,21 0,00
S. en S. (mg/l) 3,90 0,13 4,25 0,00
TOC (mg/l C) 0,26 0,01 0,31 0,00
Fósforo total (mg/l) 0,00 0,00 0,36 0,00
Nitrógeno amoniacal (mg/l) 0,30 0,01 0,03 0,00
Nitrógeno total (mg/l) 0,20 0,01 0,00 0,00
Aceites y grasas (mg/l) 0,12 0,00 0,00 0,00
Hierro (mg/l) 0,00 0,00 0,00 0,00
Níquel (mg/l) 0,00 0,00 0,00 0,00
Cobre (mg/l) 0,00 0,00 0,00 0,00
Cromo total (mg/l) 0,00 0,00 0,00 0,00
Sulfuros (mg/l) 0,00 0,00 0,00 0,00
Cianuros (mg/l) 0,00 0,00 0,01 0,00
Zinc (mg/l) 0,01 0,00 0,00 0,00
Cadmio (mg/l) 0,00 0,00 0,00 0,00
Plomo (mg/l) 0,00 0,00 0,00 0,00
Hg (mg/l) 0,00 0,00 0,00 0,00
E. coli (ufc/100 ml) 116,38 3,73 0,00 0,00
Enterococos int. (ufc/100 ml) 23,28 0,75 0,21 0,00
Tabla 6: Concentración de substancias en el efluente vertido, para los cuatro casos de
simulación considerados.

Por tanto, a partir de los resultados proporcionados por el modelo CORMIX para todas las
combinaciones consideradas en este estudio puede concluirse que la configuración de vertido
propuesta representa una solución adecuada para garantizar una dilución aceptable del vertido
final al mar.

No obstante, es preciso recordar que estos resultados proceden de simulaciones realizadas


utilizando un modelo numérico basado en condiciones medias de la descarga y del medio
receptor, y que no tiene en cuenta la variabilidad espacial y temporal tanto de las corrientes
como del viento. Simulaciones más precisas requerirían del acoplamiento de modelos
hidrodinámicos 3D y de dispersión que permitan describir de manera más detallada el
comportamiento general de la zona de estudio.

21
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

APÉNDICE A – RESULTADOS DE CORMIX PARA EL CASO S0-1

CORMIX SESSION REPORT:


XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXX
CORMIX: CORNELL MIXING ZONE EXPERT SYSTEM
CORMIX-GI Version 4.1G
SITE NAME/LABEL:
DESIGN CASE: Sagunto 10
FILE NAME: C:\Documents and Settings\MARC\Escritorio\CORMIX-
GI\Sagunto\10\Sagunto - 10.prd
Using subsystem CORMIX2: Submerged Multiport Diffuser Discharges
Start of session: 09/16/2015--11:02:44
*****************************************************************************
SUMMARY OF INPUT DATA:
-----------------------------------------------------------------------------
AMBIENT PARAMETERS:
Cross-section = unbounded
Average depth HA = 28.60 m
Depth at discharge HD = 28.60 m
Ambient velocity UA = 0 m/s
Darcy-Weisbach friction factor F = 0.0103
Calculated from Manning's n = 0.02
Wind velocity UW = 0 m/s
Stratification Type STRCND = U
Surface density RHOAS = 1027.28 kg/m^3
Bottom density RHOAB = 1027.28 kg/m^3
-----------------------------------------------------------------------------
DISCHARGE PARAMETERS: Submerged Multiport Diffuser Discharge
Diffuser type DITYPE = unidirectional parallel
Diffuser length LD = 50 m
Nearest bank = right
Diffuser endpoints YB1 = 1730 m; YB2 = 1730 m
Number of openings NOPEN = 3
Spacing between risers/openings SPAC = 25 m
Port/Nozzle diameter D0 = 0.3 m
with contraction ratio =1
Equivalent slot width B0 = 0.0042 m
Total area of openings TA0 = 0.2121 m^2
Discharge velocity U0 = 1.00 m/s
Total discharge flowrate Q0 = 0.2112 m^3/s
Discharge port height H0 = 3.13 m
Nozzle arrangement BETYPE = unidirectional without fanning
Diffuser alignment angle GAMMA = 0 deg
Vertical discharge angle THETA = 60 deg
Horizontal discharge angle SIGMA = 90 deg
Relative orientation angle BETA = 90 deg
Discharge density RHO0 = 1024.1700 kg/m^3
Density difference DRHO = 3.1100 kg/m^3
Buoyant acceleration GP0 = 0.0297 m/s^2
Discharge concentration C0 = 3520 mg/l

22
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

Surface heat exchange coeff. KS = 0 m/s


Coefficient of decay KD = 0 /s
-----------------------------------------------------------------------------
FLUX VARIABLES PER UNIT DIFFUSER LENGTH:
Discharge (volume flux) q0 = 0.004224 m^2/s
Momentum flux m0 = 0.004207 m^3/s^2
Buoyancy flux j0 = 0.000125 m^3/s^3
-----------------------------------------------------------------------------
DISCHARGE/ENVIRONMENT LENGTH SCALES:
LQ = 0.00 m Lm = 99999 m LM = 1.68 m
lm' = 99999 m Lb' = 99999 m La = 99999 m
(These refer to the actual discharge/environment length scales.)
-----------------------------------------------------------------------------
NON-DIMENSIONAL PARAMETERS:
Slot Froude number FR0 = 88.76
Port/nozzle Froude number FRD0 = 10.55
Velocity ratio R = 99999
-----------------------------------------------------------------------------
MIXING ZONE / TOXIC DILUTION ZONE / AREA OF INTEREST PARAMETERS:
Toxic discharge = no
Water quality standard specified = yes
Water quality standard CSTD = 0 mg/l
Regulatory mixing zone = no
Region of interest = 2000 m downstream
*****************************************************************************
HYDRODYNAMIC CLASSIFICATION:
*------------------------*
| FLOW CLASS = MU1V |
*------------------------*
This flow configuration applies to a layer corresponding to the full water
depth at the discharge site.
Applicable layer depth = water depth = 28.60 m
*****************************************************************************
MIXING ZONE EVALUATION (hydrodynamic and regulatory summary):

-----------------------------------------------------------------------------
X-Y-Z Coordinate system:
Origin is located at the bottom below the port center:
1730 m from the right bank/shore.
Number of display steps NSTEP = 100 per module.
-----------------------------------------------------------------------------
NEAR-FIELD REGION (NFR) CONDITIONS :
Note: The NFR is the zone of strong initial mixing. It has no regulatory implication. However,
this information may be useful for the discharge designer because the mixing in the NFR is
usually sensitive to the discharge design conditions.
Pollutant concentration at edge of NFR = 103.2876 mg/l
Dilution at edge of NFR = 34.1
NFR Location: x=0m
(centerline coordinates) y = 5.53 m
z = 26.16 m
NFR plume dimensions: half-width = 25.15 m

23
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

thickness = 2.43 m
-----------------------------------------------------------------------------
Buoyancy assessment:
The effluent density is less than the surrounding ambient water density at the discharge level.
Therefore, the effluent is POSITIVELY BUOYANT and will tend to rise towards the surface.
-----------------------------------------------------------------------------
UPSTREAM INTRUSION SUMMARY:
Plume exhibits upstream intrusion due to low ambient velocity or strong discharge buoyancy.
Intrusion length = 0m
Intrusion stagnation point = 0m
Intrusion thickness = 0m
Intrusion half width at impingement = 0 m
Intrusion half thickness at impingement = 0 m
-----------------------------------------------------------------------------
FAR-FIELD MIXING SUMMARY:
Because of the specified STAGNANT ambient conditions, there exists no steady-state far-field
for this discharge. Unsteady circulations and pollutant buid-up may result in the far-field.
-----------------------------------------------------------------------------
PLUME BANK CONTACT SUMMARY:
Plume in unbounded section does not contact bank in this simulation.
************************ TOXIC DILUTION ZONE SUMMARY ************************
No TDZ was specified for this simulation.
********************** REGULATORY MIXING ZONE SUMMARY **********************
No RMZ has been specified. The ambient water quality standard was not encountered within
the predicted plume region.
********************* FINAL DESIGN ADVICE AND COMMENTS **********************
CORMIX2 uses the TWO-DIMENSIONAL SLOT DIFFUSER CONCEPT to represent the actual
three-dimensional diffuser geometry. Thus, it approximates the details of the merging process
of the individual jets from each port/nozzle. In the present design, the spacing between
adjacent ports/nozzles (or riser assemblies) is of the order of, or less than, the local water
depth so that the slot diffuser approximation holds well.
Nevertheless, if this is a final design, the user is advised to use a final CORMIX1 (single port
discharge) analysis, with discharge data for an individual diffuser jet/plume, in order to
compare to the present near-field prediction.
-----------------------------------------------------------------------------
REMINDER: The user must take note that HYDRODYNAMIC MODELING by any known
technique is NOT AN EXACT SCIENCE. Extensive comparison with field and laboratory data has
shown that the CORMIX predictions on dilutions and concentrations (with associated plume
geometries) are reliable for the majority of cases and are accurate to within about +-50%
(standard deviation).
As a further safeguard, CORMIX will not give predictions whenever it judges the design
configuration as highly complex and uncertain for prediction.

24
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

CORMIX2 PREDICTION FILE:


2222222222222222222222222222222222222222222222222222222222222222222222222222
CORNELL MIXING ZONE EXPERT SYSTEM
Subsystem CORMIX2: Submerged Multiport Diffuser Discharges
CORMIX-GI Version 4.1G
-----------------------------------------------------------------------------
-----------------------------------------------------------------------------
CASE DESCRIPTION
Site name/label:
Design case: Sagunto_10
FILE NAME: C:\...\Escritorio\CORMIX-GI\Sagunto\10\Sagunto - 10.prd
Time stamp: Wed Sep 16 11:02:44 2015

ENVIRONMENT PARAMETERS (metric units)


Unbounded section
HA = 28.60 HD = 28.60
UA = 0.000 F = 0.010 USTAR =0.0000E+00
UW = 0.000 UWSTAR=0.0000E+00
Uniform density environment
STRCND= U RHOAM = 1027.2800

DIFFUSER DISCHARGE PARAMETERS (metric units)


Diffuser type: DITYPE= unidirectional_parallel
BANK = RIGHT DISTB = 1730.00 YB1 = 1730.00 YB2 = 1730.00
LD = 50.00 NOPEN = 3 SPAC = 25.00
D0 = 0.300 A0 = 0.071 H0 = 3.13
Nozzle/port arrangement: unidirectional_without_fanning
GAMMA = 0.00 THETA = 60.00 SIGMA = 90.00 BETA = 90.00
U0 = 0.996 Q0 = 0.211 =0.2112E+00
RHO0 = 1024.1700 DRHO0 =0.3110E+01 GP0 =0.2969E-01
C0 = 0.3520E+04 CUNITS= mg/l
IPOLL = 1 KS =0.0000E+00 KD =0.0000E+00

FLUX VARIABLES - PER UNIT DIFFUSER LENGTH (metric units)


q0 =0.4224E-02 m0 =0.4207E-02 j0 =0.1254E-03 SIGNJ0= 1.0
Associated 2-d length scales (meters)
lQ=B = 0.004 lM = 1.68 lm = 99999.00
lmp = 99999.00 lbp = 99999.00 la = 99999.00

FLUX VARIABLES - ENTIRE DIFFUSER (metric units)


Q0 =0.2112E+00 M0 =0.2103E+00 J0 =0.6270E-02
Associated 3-d length scales (meters)
LQ = 0.46 LM = 3.92 Lm = 99999.00 Lb = 99999.00
Lmp = 99999.00 Lbp = 99999.00

NON-DIMENSIONAL PARAMETERS
FR0 = 88.76 FRD0 = 10.55 R = 99999.00
(slot) (port/nozzle)

FLOW CLASSIFICATION
222222222222222222222222222222222222222222

25
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

2 Flow class (CORMIX2) = MU1V 2


2 Applicable layer depth HS = 28.60 2
222222222222222222222222222222222222222222

MIXING ZONE / TOXIC DILUTION / REGION OF INTEREST PARAMETERS


C0 = 0.3520E+04 CUNITS= mg/l
NTOX = 0
NSTD = 1 CSTD =0.0000E+00
REGMZ = 0
XINT = 2000.00 XMAX = 2000.00

X-Y-Z COORDINATE SYSTEM:


ORIGIN is located at the bottom and the diffuser mid-point:
1730.00 m from the RIGHT bank/shore.
X-axis points downstream, Y-axis points to left, Z-axis points upward.
NSTEP =100 display intervals per module
-----------------------------------------------------------------------------
-----------------------------------------------------------------------------
BEGIN MOD101: DISCHARGE MODULE (SINGLE PORT AT DIFFUSER CENTER)
X Y Z S C BV BH
0.00 0.00 3.13 1.0 0.352E+04 0.15 0.15

END OF MOD101: DISCHARGE MODULE (SINGLE PORT AT DIFFUSER CENTER)


-----------------------------------------------------------------------------
-----------------------------------------------------------------------------
BEGIN CORJET (MOD110): JET/PLUME NEAR-FIELD MIXING REGION

Jet/plume transition motion in weak crossflow.


Zone of flow establishment: THETAE= 60.00 SIGMAE= 90.00
LE = 1.50 XE = 0.00 YE = 0.75 ZE = 4.43

Profile definitions:
BV = Gaussian 1/e (37%) half-width, in vertical plane normal to trajectory
BH = before merging: Gaussian 1/e (37%) half-width in horizontal plane normal to trajectory
after merging: top-hat half-width in horizontal plane parallel to diffuser line
S = hydrodynamic centerline dilution
C = centerline concentration (includes reaction effects, if any)

X Y Z S C BV BH
Individual jet/plumes before merging:
0.00 0.75 4.43 1.0 0.352E+04 0.15 0.15
0.00 0.75 4.43 1.0 0.352E+04 0.15 0.15
0.00 0.86 4.62 1.0 0.352E+04 0.17 0.17
0.00 0.97 4.82 1.1 0.314E+04 0.20 0.20
0.00 1.08 5.01 1.3 0.278E+04 0.22 0.22
0.00 1.19 5.21 1.4 0.249E+04 0.25 0.25
0.00 1.29 5.41 1.6 0.224E+04 0.27 0.27
0.00 1.40 5.61 1.7 0.204E+04 0.30 0.30
0.00 1.50 5.81 1.9 0.187E+04 0.32 0.32
0.00 1.60 6.01 2.0 0.172E+04 0.35 0.35
0.00 1.70 6.21 2.2 0.159E+04 0.37 0.37

26
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

0.00 1.79 6.41 2.4 0.148E+04 0.39 0.39


0.00 1.89 6.62 2.5 0.138E+04 0.42 0.42
0.00 1.98 6.82 2.7 0.129E+04 0.44 0.44
0.00 2.07 7.02 2.9 0.121E+04 0.46 0.46
0.00 2.16 7.23 3.1 0.114E+04 0.49 0.49
0.00 2.24 7.44 3.3 0.107E+04 0.51 0.51
0.00 2.33 7.65 3.5 0.101E+04 0.54 0.54
0.00 2.41 7.86 3.7 0.960E+03 0.56 0.56
0.00 2.49 8.07 3.9 0.910E+03 0.58 0.58
0.00 2.57 8.28 4.1 0.864E+03 0.61 0.61
0.00 2.64 8.49 4.3 0.821E+03 0.63 0.63
0.00 2.72 8.70 4.5 0.782E+03 0.65 0.65
0.00 2.79 8.91 4.7 0.745E+03 0.68 0.68
0.00 2.86 9.13 4.9 0.712E+03 0.70 0.70
0.00 2.93 9.34 5.2 0.680E+03 0.72 0.72
0.00 3.00 9.56 5.4 0.651E+03 0.75 0.75
0.00 3.06 9.77 5.6 0.624E+03 0.77 0.77
0.00 3.13 9.98 5.9 0.598E+03 0.79 0.79
0.00 3.19 10.20 6.1 0.574E+03 0.82 0.82
0.00 3.25 10.42 6.4 0.552E+03 0.84 0.84
0.00 3.31 10.63 6.6 0.530E+03 0.86 0.86
0.00 3.37 10.85 6.9 0.510E+03 0.88 0.88
0.00 3.42 11.07 7.2 0.492E+03 0.91 0.91
0.00 3.48 11.28 7.4 0.474E+03 0.93 0.93
0.00 3.53 11.50 7.7 0.457E+03 0.95 0.95
0.00 3.58 11.72 8.0 0.441E+03 0.98 0.98
0.00 3.64 11.94 8.3 0.426E+03 1.00 1.00
0.00 3.69 12.16 8.5 0.412E+03 1.02 1.02
0.00 3.73 12.37 8.8 0.399E+03 1.04 1.04
0.00 3.78 12.59 9.1 0.386E+03 1.07 1.07
0.00 3.83 12.81 9.4 0.374E+03 1.09 1.09
0.00 3.88 13.03 9.7 0.362E+03 1.11 1.11
0.00 3.92 13.25 10.0 0.351E+03 1.13 1.13
0.00 3.96 13.47 10.3 0.340E+03 1.16 1.16
0.00 4.01 13.70 10.7 0.330E+03 1.18 1.18
0.00 4.05 13.92 11.0 0.321E+03 1.20 1.20
0.00 4.09 14.14 11.3 0.312E+03 1.23 1.23
0.00 4.13 14.36 11.6 0.303E+03 1.25 1.25
0.00 4.17 14.58 12.0 0.295E+03 1.27 1.27
0.00 4.21 14.80 12.3 0.286E+03 1.29 1.29
0.00 4.25 15.02 12.6 0.279E+03 1.32 1.32
0.00 4.29 15.24 13.0 0.272E+03 1.34 1.34
0.00 4.32 15.46 13.3 0.265E+03 1.36 1.36
0.00 4.36 15.68 13.7 0.258E+03 1.38 1.38
0.00 4.39 15.91 14.0 0.251E+03 1.41 1.41
0.00 4.43 16.13 14.4 0.245E+03 1.43 1.43
0.00 4.46 16.35 14.7 0.239E+03 1.45 1.45
0.00 4.50 16.57 15.1 0.233E+03 1.47 1.47
0.00 4.53 16.79 15.5 0.228E+03 1.50 1.50
0.00 4.56 17.02 15.8 0.222E+03 1.52 1.52
0.00 4.59 17.24 16.2 0.217E+03 1.54 1.54

27
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

0.00 4.62 17.46 16.6 0.212E+03 1.56 1.56


0.00 4.65 17.68 17.0 0.207E+03 1.59 1.59
0.00 4.68 17.91 17.4 0.203E+03 1.61 1.61
0.00 4.71 18.13 17.7 0.198E+03 1.63 1.63
0.00 4.74 18.35 18.1 0.194E+03 1.65 1.65
0.00 4.77 18.57 18.5 0.190E+03 1.68 1.68
0.00 4.80 18.79 18.9 0.186E+03 1.70 1.70
0.00 4.83 19.02 19.3 0.182E+03 1.72 1.72
0.00 4.85 19.24 19.8 0.178E+03 1.74 1.74
0.00 4.88 19.46 20.2 0.175E+03 1.76 1.76
0.00 4.91 19.69 20.6 0.171E+03 1.79 1.79
0.00 4.93 19.91 21.0 0.168E+03 1.81 1.81
0.00 4.96 20.13 21.4 0.164E+03 1.83 1.83
0.00 4.98 20.36 21.9 0.161E+03 1.85 1.85
0.00 5.01 20.58 22.3 0.158E+03 1.88 1.88
0.00 5.03 20.80 22.7 0.155E+03 1.90 1.90
0.00 5.06 21.02 23.1 0.152E+03 1.92 1.92
0.00 5.08 21.25 23.6 0.149E+03 1.94 1.94
0.00 5.11 21.47 24.0 0.147E+03 1.97 1.97
0.00 5.13 21.69 24.5 0.144E+03 1.99 1.99
0.00 5.15 21.92 24.9 0.141E+03 2.01 2.01
0.00 5.17 22.14 25.4 0.139E+03 2.03 2.03
0.00 5.20 22.36 25.8 0.136E+03 2.06 2.06
0.00 5.22 22.59 26.3 0.134E+03 2.08 2.08
0.00 5.24 22.81 26.8 0.132E+03 2.10 2.10
0.00 5.26 23.03 27.2 0.129E+03 2.12 2.12
0.00 5.28 23.26 27.7 0.127E+03 2.14 2.14
0.00 5.30 23.48 28.2 0.125E+03 2.17 2.17
0.00 5.32 23.70 28.6 0.123E+03 2.19 2.19
0.00 5.34 23.93 29.1 0.121E+03 2.21 2.21
0.00 5.36 24.15 29.6 0.119E+03 2.23 2.23
0.00 5.38 24.37 30.1 0.117E+03 2.26 2.26
0.00 5.40 24.60 30.6 0.115E+03 2.28 2.28
0.00 5.42 24.82 31.1 0.113E+03 2.30 2.30
0.00 5.44 25.05 31.6 0.112E+03 2.32 2.32
0.00 5.46 25.27 32.1 0.110E+03 2.35 2.35
0.00 5.48 25.49 32.6 0.108E+03 2.37 2.37
0.00 5.50 25.71 33.1 0.106E+03 2.39 2.39
0.00 5.51 25.94 33.6 0.105E+03 2.41 2.41
0.00 5.53 26.16 34.1 0.103E+03 2.43 2.43
Cumulative travel time = 75. sec
Merging of individual jet/plumes not found in this module, but interaction
will occur in following module. Overall jet/plume interaction dimensions:
0.00 5.53 26.16 34.1 0.103E+03 2.43 25.15

END OF CORJET (MOD110): JET/PLUME NEAR-FIELD MIXING REGION


-----------------------------------------------------------------------------
-----------------------------------------------------------------------------
BEGIN MOD232: LAYER BOUNDARY IMPINGEMENT/UPSTREAM SPREADING

Vertical angle of layer/boundary impingement = 85.47 deg

28
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

Horizontal angle of layer/boundary impingement = 90.00 deg

Discharge into STAGNANT AMBIENT environment:


STEADY-STATE MIXING CONDITION IS NOT POSSIBLE in this zone,
even though some ADDITIONAL DILUTION MAY OCCUR!
Also, all far-field processes will be UNSTEADY.
SIMULATION STOPS because of stagnant ambient conditions.

END OF MOD232: LAYER BOUNDARY IMPINGEMENT/UPSTREAM SPREADING


-----------------------------------------------------------------------------
** End of NEAR-FIELD REGION (NFR) **

SIMULATION STOPS because of STAGNANT AMBIENT conditions.


All far-field processes will be UNSTEADY.
-----------------------------------------------------------------------------
CORMIX2: Submerged Multiport Diffuser Discharges End of Prediction File
2222222222222222222222222222222222222222222222222222222222222222222222222222

29
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

APÉNDICE B – RESULTADOS DE CORMIX PARA EL CASO S0-1b

CORMIX SESSION REPORT:


XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXX
CORMIX: CORNELL MIXING ZONE EXPERT SYSTEM
CORMIX-GI Version 4.1G
SITE NAME/LABEL:
DESIGN CASE: Sagunto 10b
FILE NAME: C:\Documents and Settings\MARC\Escritorio\CORMIX-GI\Sagunto -
10b.prd
Using subsystem CORMIX1: Submerged Single Port Discharges
Start of session: 09/16/2015--10:20:38
*****************************************************************************
SUMMARY OF INPUT DATA:
-----------------------------------------------------------------------------
AMBIENT PARAMETERS:
Cross-section = unbounded
Average depth HA = 28.60 m
Depth at discharge HD = 28.60 m
Ambient velocity UA = 0 m/s
Darcy-Weisbach friction factor F = 0.0103
Calculated from Manning's n = 0.02
Wind velocity UW = 0 m/s
Stratification Type STRCND = U
Surface density RHOAS = 1027.28 kg/m^3
Bottom density RHOAB = 1027.28 kg/m^3
-----------------------------------------------------------------------------
DISCHARGE PARAMETERS: Submerged Single Port Discharge
Nearest bank = right
Distance to bank DISTB = 1730 m
Port diameter D0 = 0.3 m
Port cross-sectional area A0 = 0.0707 m^2
Discharge velocity U0 = 1.00 m/s
Discharge flowrate Q0 = 0.0704 m^3/s
Discharge port height H0 = 3.13 m
Vertical discharge angle THETA = 60 deg
Horizontal discharge angle SIGMA = 90 deg
Discharge density RHO0 = 1024.1660 kg/m^3
Density difference DRHO = 3.1140 kg/m^3
Buoyant acceleration GP0 = 0.0297 m/s^2
Discharge concentration C0 = 3520 mg/l
Surface heat exchange coeff. KS = 0 m/s
Coefficient of decay KD = 0 /s
-----------------------------------------------------------------------------
DISCHARGE/ENVIRONMENT LENGTH SCALES:
LQ = 0.27 m Lm = 99999 m Lb = 99999 m
LM = 2.98 m Lm' = 99999 m Lb' = 99999 m
-----------------------------------------------------------------------------
NON-DIMENSIONAL PARAMETERS:
Port densimetric Froude number FR0 = 10.55

30
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

Velocity ratio R = 99999


-----------------------------------------------------------------------------
MIXING ZONE / TOXIC DILUTION ZONE / AREA OF INTEREST PARAMETERS:
Toxic discharge = no
Water quality standard specified = yes
Water quality standard CSTD = 0 mg/l
Regulatory mixing zone = no
Region of interest = 2000 m downstream
*****************************************************************************
HYDRODYNAMIC CLASSIFICATION:
*------------------------*
| FLOW CLASS = V5 |
*------------------------*
This flow configuration applies to a layer corresponding to the full water depth at the
discharge site.
Applicable layer depth = water depth = 28.60 m
*****************************************************************************
MIXING ZONE EVALUATION (hydrodynamic and regulatory summary):

-----------------------------------------------------------------------------
X-Y-Z Coordinate system:
Origin is located at the bottom below the port center:
1730 m from the right bank/shore.
Number of display steps NSTEP = 100 per module.
-----------------------------------------------------------------------------
NEAR-FIELD REGION (NFR) CONDITIONS :
Note: The NFR is the zone of strong initial mixing. It has no regulatory implication. However,
this information may be useful for the discharge designer because the mixing in the NFR is
usually sensitive to the discharge design conditions.
Pollutant concentration at edge of NFR = 103.1609 mg/l
Dilution at edge of NFR = 34.1
NFR Location: x=0m
(centerline coordinates) y = 5.52 m
z = 26.16 m
NFR plume dimensions: half-width = 0.15 m
thickness = 0.15 m
-----------------------------------------------------------------------------
Buoyancy assessment:
The effluent density is less than the surrounding ambient water density at the discharge level.
Therefore, the effluent is POSITIVELY BUOYANT and will tend to rise towards the surface.
----------------------------------------------------------------------------
Near-field instability behavior:
The discharge flow will experience instabilities with full vertical mixing
in the near-field. There may be benthic impact of high pollutant concentrations.
-----------------------------------------------------------------------------
UPSTREAM INTRUSION SUMMARY:
Plume exhibits upstream intrusion due to low ambient velocity or strong discharge buoyancy.
Intrusion length = 0m
Intrusion stagnation point = 0m
Intrusion thickness = 0m
Intrusion half width at impingement = 0 m

31
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

Intrusion half thickness at impingement = 0 m


-----------------------------------------------------------------------------
FAR-FIELD MIXING SUMMARY:
Because of the specified STAGNANT ambient conditions, there exists no steady-state far-field
for this discharge. Unsteady circulations and pollutant buid-up may result in the far-field.
-----------------------------------------------------------------------------
PLUME BANK CONTACT SUMMARY:
Plume in unbounded section does not contact bank in this simulation.
************************ TOXIC DILUTION ZONE SUMMARY ************************
No TDZ was specified for this simulation.
********************** REGULATORY MIXING ZONE SUMMARY **********************
No RMZ has been specified.
The ambient water quality standard was not encountered within the predicted plume region.
********************* FINAL DESIGN ADVICE AND COMMENTS **********************
REMINDER: The user must take note that HYDRODYNAMIC MODELING by any known
technique is NOT AN EXACT SCIENCE. Extensive comparison with field and laboratory data has
shown that the CORMIX predictions on dilutions and concentrations (with associated plume
geometries) are reliable for the majority of cases and are accurate to within about +-50%
(standard deviation). As a further safeguard, CORMIX will not give predictions whenever it
judges the design configuration as highly complex and uncertain for prediction.

32
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

CORMIX1 PREDICTION FILE:


1111111111111111111111111111111111111111111111111111111111111111111111111111
1
CORNELL MIXING ZONE EXPERT SYSTEM
Subsystem CORMIX1: Submerged Single Port Discharges
CORMIX-GI Version 4.1G
-----------------------------------------------------------------------------
-----------------------------------------------------------------------------
CASE DESCRIPTION
Site name/label:
Design case: Sagunto_10b
FILE NAME: C:\...tings\MARC\Escritorio\CORMIX-GI\Sagunto - 10b.prd
Time stamp: Wed Sep 16 10:20:38 2015

ENVIRONMENT PARAMETERS (metric units)


Unbounded section
HA = 28.60 HD = 28.60
UA = 0.000 F = 0.010 USTAR =0.0000E+00
UW = 0.000 UWSTAR=0.0000E+00
Uniform density environment
STRCND= U RHOAM = 1027.2800

DISCHARGE PARAMETERS (metric units)


BANK = RIGHT DISTB = 1730.00
D0 = 0.300 A0 = 0.071 H0 = 3.13
THETA = 60.00 SIGMA = 90.00
U0 = 0.996 Q0 = 0.070 =0.7040E-01
RHO0 = 1024.1660 DRHO0 =0.3114E+01 GP0 =0.2973E-01
C0 = 0.3520E+04 CUNITS= mg/l
IPOLL = 1 KS =0.0000E+00 KD =0.0000E+00

FLUX VARIABLES (metric units)


Q0 =0.7040E-01 M0 =0.7012E-01 J0 =0.2093E-02 SIGNJ0= 1.0
Associated length scales (meters)
LQ = 0.27 LM = 2.98 Lm = 99999.00 Lb = 99999.00
Lmp = 99999.00 Lbp = 99999.00

NON-DIMENSIONAL PARAMETERS
FR0 = 10.55 R = 99999.00

FLOW CLASSIFICATION
111111111111111111111111111111111111111111
1 Flow class (CORMIX1) = V5 1
1 Applicable layer depth HS = 28.60 1
111111111111111111111111111111111111111111

MIXING ZONE / TOXIC DILUTION / REGION OF INTEREST PARAMETERS


C0 = 0.3520E+04 CUNITS= mg/l
NTOX = 0
NSTD = 1 CSTD =0.0000E+00
REGMZ = 0

33
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

XINT = 2000.00 XMAX = 2000.00

X-Y-Z COORDINATE SYSTEM:


ORIGIN is located at the bottom and below the center of the port:
1730.00 m from the RIGHT bank/shore.
X-axis points downstream, Y-axis points to left, Z-axis points upward.
NSTEP =100 display intervals per module
-----------------------------------------------------------------------------
-----------------------------------------------------------------------------
BEGIN MOD101: DISCHARGE MODULE

X Y Z S C B
0.00 0.00 3.13 1.0 0.352E+04 0.15

END OF MOD101: DISCHARGE MODULE


-----------------------------------------------------------------------------
-----------------------------------------------------------------------------
BEGIN CORJET (MOD110): JET/PLUME NEAR-FIELD MIXING REGION

Zone of flow establishment: THETAE= 60.00 SIGMAE= 90.00


LE = 1.48 XE = 0.00 YE = 0.74 ZE = 4.41

Profile definitions:
B = Gaussian 1/e (37%) half-width, normal to trajectory
S = hydrodynamic centerline dilution
C = centerline concentration (includes reaction effects, if any)

X Y Z S C B
0.00 0.00 3.13 1.0 0.352E+04 0.15
0.00 0.74 4.41 1.0 0.352E+04 0.16
0.00 0.80 4.51 1.0 0.352E+04 0.17
0.00 0.91 4.71 1.1 0.314E+04 0.20
0.00 1.02 4.90 1.3 0.278E+04 0.22
0.00 1.13 5.10 1.4 0.249E+04 0.25
0.00 1.23 5.30 1.6 0.225E+04 0.27
0.00 1.34 5.50 1.7 0.204E+04 0.30
0.00 1.44 5.70 1.9 0.187E+04 0.32
0.00 1.54 5.90 2.0 0.172E+04 0.34
0.00 1.64 6.10 2.2 0.160E+04 0.37
0.00 1.74 6.30 2.4 0.148E+04 0.39
0.00 1.83 6.50 2.5 0.138E+04 0.42
0.00 1.93 6.71 2.7 0.129E+04 0.44
0.00 2.02 6.91 2.9 0.121E+04 0.46
0.00 2.11 7.12 3.1 0.114E+04 0.49
0.00 2.19 7.33 3.3 0.107E+04 0.51
0.00 2.28 7.53 3.5 0.101E+04 0.54
0.00 2.36 7.74 3.7 0.959E+03 0.56
0.00 2.44 7.95 3.9 0.909E+03 0.58
0.00 2.52 8.16 4.1 0.863E+03 0.61
0.00 2.60 8.37 4.3 0.821E+03 0.63
0.00 2.67 8.59 4.5 0.782E+03 0.65

34
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

0.00 2.75 8.80 4.7 0.745E+03 0.68


0.00 2.82 9.01 4.9 0.712E+03 0.70
0.00 2.89 9.22 5.2 0.680E+03 0.72
0.00 2.96 9.44 5.4 0.651E+03 0.75
0.00 3.02 9.65 5.6 0.623E+03 0.77
0.00 3.09 9.87 5.9 0.598E+03 0.79
0.00 3.15 10.08 6.1 0.574E+03 0.82
0.00 3.21 10.30 6.4 0.551E+03 0.84
0.00 3.27 10.52 6.6 0.530E+03 0.86
0.00 3.33 10.73 6.9 0.510E+03 0.88
0.00 3.39 10.95 7.2 0.491E+03 0.91
0.00 3.47 11.28 7.6 0.465E+03 0.94
0.00 3.52 11.49 7.8 0.449E+03 0.96
0.00 3.58 11.71 8.1 0.433E+03 0.99
0.00 3.63 11.93 8.4 0.419E+03 1.01
0.00 3.68 12.15 8.7 0.405E+03 1.03
0.00 3.73 12.37 9.0 0.392E+03 1.06
0.00 3.77 12.59 9.3 0.379E+03 1.08
0.00 3.82 12.81 9.6 0.367E+03 1.10
0.00 3.87 13.03 9.9 0.356E+03 1.12
0.00 3.91 13.25 10.2 0.345E+03 1.15
0.00 3.96 13.47 10.5 0.335E+03 1.17
0.00 4.00 13.69 10.8 0.325E+03 1.19
0.00 4.04 13.91 11.1 0.316E+03 1.21
0.00 4.08 14.13 11.5 0.307E+03 1.24
0.00 4.12 14.35 11.8 0.298E+03 1.26
0.00 4.16 14.57 12.1 0.290E+03 1.28
0.00 4.20 14.79 12.5 0.282E+03 1.30
0.00 4.24 15.01 12.8 0.275E+03 1.33
0.00 4.28 15.24 13.1 0.268E+03 1.35
0.00 4.31 15.46 13.5 0.261E+03 1.37
0.00 4.35 15.68 13.8 0.254E+03 1.39
0.00 4.39 15.90 14.2 0.248E+03 1.42
0.00 4.42 16.12 14.6 0.242E+03 1.44
0.00 4.45 16.34 14.9 0.236E+03 1.46
0.00 4.49 16.57 15.3 0.230E+03 1.48
0.00 4.52 16.79 15.7 0.225E+03 1.51
0.00 4.55 17.01 16.0 0.220E+03 1.53
0.00 4.58 17.23 16.4 0.214E+03 1.55
0.00 4.61 17.46 16.8 0.210E+03 1.57
0.00 4.65 17.68 17.2 0.205E+03 1.60
0.00 4.68 17.90 17.6 0.200E+03 1.62
0.00 4.71 18.12 18.0 0.196E+03 1.64
0.00 4.73 18.35 18.4 0.192E+03 1.66
0.00 4.76 18.57 18.8 0.188E+03 1.69
0.00 4.79 18.79 19.2 0.184E+03 1.71
0.00 4.82 19.01 19.6 0.180E+03 1.73
0.00 4.85 19.24 20.0 0.176E+03 1.75
0.00 4.87 19.46 20.4 0.173E+03 1.78
0.00 4.90 19.68 20.8 0.169E+03 1.80
0.00 4.92 19.91 21.2 0.166E+03 1.82

35
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

0.00 4.95 20.13 21.7 0.163E+03 1.84


0.00 4.98 20.35 22.1 0.159E+03 1.87
0.00 5.00 20.57 22.5 0.156E+03 1.89
0.00 5.02 20.80 22.9 0.153E+03 1.91
0.00 5.05 21.02 23.4 0.151E+03 1.93
0.00 5.07 21.24 23.8 0.148E+03 1.96
0.00 5.10 21.47 24.3 0.145E+03 1.98
0.00 5.12 21.69 24.7 0.142E+03 2.00
0.00 5.14 21.91 25.2 0.140E+03 2.02
0.00 5.16 22.14 25.6 0.137E+03 2.04
0.00 5.19 22.36 26.1 0.135E+03 2.07
0.00 5.21 22.59 26.5 0.133E+03 2.09
0.00 5.23 22.81 27.0 0.130E+03 2.11
0.00 5.25 23.03 27.5 0.128E+03 2.13
0.00 5.27 23.26 28.0 0.126E+03 2.16
0.00 5.29 23.48 28.4 0.124E+03 2.18
0.00 5.31 23.70 28.9 0.122E+03 2.20
0.00 5.33 23.93 29.4 0.120E+03 2.22
0.00 5.35 24.15 29.9 0.118E+03 2.25
0.00 5.37 24.37 30.4 0.116E+03 2.27
0.00 5.39 24.60 30.9 0.114E+03 2.29
0.00 5.41 24.82 31.3 0.112E+03 2.31
0.00 5.43 25.05 31.8 0.111E+03 2.34
0.00 5.45 25.27 32.3 0.109E+03 2.36
0.00 5.47 25.49 32.8 0.107E+03 2.38
0.00 5.49 25.72 33.4 0.106E+03 2.40
0.00 5.50 25.94 33.9 0.104E+03 2.42
0.00 5.52 26.16 34.1 0.103E+03 2.44
Cumulative travel time = 75. sec

END OF CORJET (MOD110): JET/PLUME NEAR-FIELD MIXING REGION


-----------------------------------------------------------------------------
-----------------------------------------------------------------------------
BEGIN MOD132: LAYER BOUNDARY IMPINGEMENT/UPSTREAM SPREADING

Vertical angle of layer/boundary impingement = 85.46 deg


Horizontal angle of layer/boundary impingement = 90.00 deg

Discharge into STAGNANT AMBIENT environment:


STEADY-STATE MIXING CONDITION IS NOT POSSIBLE in this zone,
even though some ADDITIONAL DILUTION MAY OCCUR!
Also, all far-field processes will be UNSTEADY.
SIMULATION STOPS because of stagnant ambient conditions.

END OF MOD132: LAYER BOUNDARY IMPINGEMENT/UPSTREAM SPREADING


-----------------------------------------------------------------------------
** End of NEAR-FIELD REGION (NFR) **

SIMULATION STOPS because of STAGNANT AMBIENT conditions.


All far-field processes will be UNSTEADY.

36
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

-----------------------------------------------------------------------------
CORMIX1: Submerged Single Port Discharges End of Prediction File
1111111111111111111111111111111111111111111111111111111111111111111111111111
1

APÉNDICE C – RESULTADOS DE CORMIX PARA EL CASO S0-3

37
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

38
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

39
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

40
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

41
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

42
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

43
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

44
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

45
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

46
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

APÉNDICE D – RESULTADOS DE CORMIX PARA EL CASO S2-0

CORMIX SESSION REPORT:


XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXX
CORMIX: CORNELL MIXING ZONE EXPERT SYSTEM
CORMIX-GI Version 4.1G
SITE NAME/LABEL:
DESIGN CASE: Sagunto 20
FILE NAME: C:\Documents and Settings\MARC\Escritorio\CORMIX-
GI\Sagunto\20\Sagunto - 20.prd
Using subsystem CORMIX2: Submerged Multiport Diffuser Discharges
Start of session: 09/16/2015--11:01:34
*****************************************************************************
SUMMARY OF INPUT DATA:
-----------------------------------------------------------------------------
AMBIENT PARAMETERS:
Cross-section = unbounded
Average depth HA = 28.60 m
Depth at discharge HD = 28.60 m
Ambient velocity UA = 0 m/s
Darcy-Weisbach friction factor F = 0.0103
Calculated from Manning's n = 0.02
Wind velocity UW = 0 m/s
Stratification Type STRCND = U
Surface density RHOAS = 1027.28 kg/m^3
Bottom density RHOAB = 1027.28 kg/m^3
-----------------------------------------------------------------------------
DISCHARGE PARAMETERS: Submerged Multiport Diffuser Discharge
Diffuser type DITYPE = unidirectional parallel
Diffuser length LD = 50 m
Nearest bank = right
Diffuser endpoints YB1 = 1730 m; YB2 = 1730 m
Number of openings NOPEN = 3
Spacing between risers/openings SPAC = 25 m
Port/Nozzle diameter D0 = 0.3 m
with contraction ratio =1
Equivalent slot width B0 = 0.0042 m
Total area of openings TA0 = 0.2121 m^2
Discharge velocity U0 = 0.60 m/s
Total discharge flowrate Q0 = 0.1275 m^3/s
Discharge port height H0 = 3.13 m
Nozzle arrangement BETYPE = unidirectional without fanning
Diffuser alignment angle GAMMA = 0 deg
Vertical discharge angle THETA = 60 deg
Horizontal discharge angle SIGMA = 90 deg
Relative orientation angle BETA = 90 deg
Discharge density RHO0 = 1023.95 kg/m^3
Density difference DRHO = 3.3300 kg/m^3
Buoyant acceleration GP0 = 0.0318 m/s^2

47
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

Discharge concentration C0 = 3800 mg/l


Surface heat exchange coeff. KS = 0 m/s
Coefficient of decay KD = 0 /s
-----------------------------------------------------------------------------
FLUX VARIABLES PER UNIT DIFFUSER LENGTH:
Discharge (volume flux) q0 = 0.00255 m^2/s
Momentum flux m0 = 0.001533 m^3/s^2
Buoyancy flux j0 = 0.000081 m^3/s^3
-----------------------------------------------------------------------------
DISCHARGE/ENVIRONMENT LENGTH SCALES:
LQ = 0.00 m Lm = 99999 m LM = 0.82 m
lm' = 99999 m Lb' = 99999 m La = 99999 m
(These refer to the actual discharge/environment length scales.)
-----------------------------------------------------------------------------
NON-DIMENSIONAL PARAMETERS:
Slot Froude number FR0 = 51.78
Port/nozzle Froude number FRD0 = 6.16
Velocity ratio R = 99999
-----------------------------------------------------------------------------
MIXING ZONE / TOXIC DILUTION ZONE / AREA OF INTEREST PARAMETERS:
Toxic discharge = no
Water quality standard specified = yes
Water quality standard CSTD = 0 mg/l
Regulatory mixing zone = no
Region of interest = 2000 m downstream
*****************************************************************************
HYDRODYNAMIC CLASSIFICATION:
*------------------------*
| FLOW CLASS = MU1V |
*------------------------*
This flow configuration applies to a layer corresponding to the full water depth at the
discharge site.
Applicable layer depth = water depth = 28.60 m
*****************************************************************************
MIXING ZONE EVALUATION (hydrodynamic and regulatory summary):

-----------------------------------------------------------------------------
X-Y-Z Coordinate system:
Origin is located at the bottom below the port center:
1730 m from the right bank/shore.
Number of display steps NSTEP = 100 per module.
-----------------------------------------------------------------------------
NEAR-FIELD REGION (NFR) CONDITIONS :
Note: The NFR is the zone of strong initial mixing. It has no regulatory implication. However,
this information may be useful for the discharge designer because the mixing in the NFR is
usually sensitive to the discharge design conditions.
Pollutant concentration at edge of NFR = 81.701600 mg/l
Dilution at edge of NFR = 46.5
NFR Location: x=0m
(centerline coordinates) y = 3.87 m
z = 26.22 m

48
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

NFR plume dimensions: half-width = 25.15 m


thickness = 2.38 m
-----------------------------------------------------------------------------
Buoyancy assessment:
The effluent density is less than the surrounding ambient water density at the discharge level.
Therefore, the effluent is POSITIVELY BUOYANT and will tend to rise towards the surface.
-----------------------------------------------------------------------------
UPSTREAM INTRUSION SUMMARY:
Plume exhibits upstream intrusion due to low ambient velocity or strong discharge buoyancy.
Intrusion length = 0m
Intrusion stagnation point = 0m
Intrusion thickness = 0m
Intrusion half width at impingement = 0 m
Intrusion half thickness at impingement = 0 m
-----------------------------------------------------------------------------
FAR-FIELD MIXING SUMMARY:
Because of the specified STAGNANT ambient conditions, there exists no steady-state far-field
for this discharge. Unsteady circulations and pollutant buid-up may result in the far-field.
-----------------------------------------------------------------------------
PLUME BANK CONTACT SUMMARY:
Plume in unbounded section does not contact bank in this simulation.
************************ TOXIC DILUTION ZONE SUMMARY ************************
No TDZ was specified for this simulation.
********************** REGULATORY MIXING ZONE SUMMARY **********************
No RMZ has been specified.
The ambient water quality standard was not encountered within the predicted plume region.
********************* FINAL DESIGN ADVICE AND COMMENTS **********************
CORMIX2 uses the TWO-DIMENSIONAL SLOT DIFFUSER CONCEPT to represent the actual
three-dimensional diffuser geometry. Thus, it approximates the details of the merging process
of the individual jets from each port/nozzle. In the present design, the spacing between
adjacent ports/nozzles (or riser assemblies) is of the order of, or less than, the local water
depth so that the slot diffuser approximation holds well.

Nevertheless, if this is a final design, the user is advised to use a final CORMIX1 (single port
discharge) analysis, with discharge data for an individual diffuser jet/plume, in order to
compare to the present near-field prediction.
-----------------------------------------------------------------------------
REMINDER: The user must take note that HYDRODYNAMIC MODELING by any known
technique is NOT AN EXACT SCIENCE. Extensive comparison with field and laboratory data has
shown that the CORMIX predictions on dilutions and concentrations (with associated plume
geometries) are reliable for the majority of cases and are accurate to within about +-50%
(standard deviation).
As a further safeguard, CORMIX will not give predictions whenever it judges the design
configuration as highly complex and uncertain for prediction.

49
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

CORMIX2 PREDICTION FILE:


2222222222222222222222222222222222222222222222222222222222222222222222222222
CORNELL MIXING ZONE EXPERT SYSTEM
Subsystem CORMIX2: Submerged Multiport Diffuser Discharges
CORMIX-GI Version 4.1G
-----------------------------------------------------------------------------
-----------------------------------------------------------------------------
CASE DESCRIPTION
Site name/label:
Design case: Sagunto_20
FILE NAME: C:\...\Escritorio\CORMIX-GI\Sagunto\20\Sagunto - 20.prd
Time stamp: Wed Sep 16 11:01:34 2015

ENVIRONMENT PARAMETERS (metric units)


Unbounded section
HA = 28.60 HD = 28.60
UA = 0.000 F = 0.010 USTAR =0.0000E+00
UW = 0.000 UWSTAR=0.0000E+00
Uniform density environment
STRCND= U RHOAM = 1027.2800

DIFFUSER DISCHARGE PARAMETERS (metric units)


Diffuser type: DITYPE= unidirectional_parallel
BANK = RIGHT DISTB = 1730.00 YB1 = 1730.00 YB2 = 1730.00
LD = 50.00 NOPEN = 3 SPAC = 25.00
D0 = 0.300 A0 = 0.071 H0 = 3.13
Nozzle/port arrangement: unidirectional_without_fanning
GAMMA = 0.00 THETA = 60.00 SIGMA = 90.00 BETA = 90.00
U0 = 0.601 Q0 = 0.127 =0.1275E+00
RHO0 = 1023.9500 DRHO0 =0.3330E+01 GP0 =0.3179E-01
C0 = 0.3800E+04 CUNITS= mg/l
IPOLL = 1 KS =0.0000E+00 KD =0.0000E+00

FLUX VARIABLES - PER UNIT DIFFUSER LENGTH (metric units)


q0 =0.2550E-02 m0 =0.1533E-02 j0 =0.8106E-04 SIGNJ0= 1.0
Associated 2-d length scales (meters)
lQ=B = 0.004 lM = 0.82 lm = 99999.00
lmp = 99999.00 lbp = 99999.00 la = 99999.00

FLUX VARIABLES - ENTIRE DIFFUSER (metric units)


Q0 =0.1275E+00 M0 =0.7666E-01 J0 =0.4053E-02
Associated 3-d length scales (meters)
LQ = 0.46 LM = 2.29 Lm = 99999.00 Lb = 99999.00
Lmp = 99999.00 Lbp = 99999.00

NON-DIMENSIONAL PARAMETERS
FR0 = 51.78 FRD0 = 6.16 R = 99999.00
(slot) (port/nozzle)

FLOW CLASSIFICATION
222222222222222222222222222222222222222222

50
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

2 Flow class (CORMIX2) = MU1V 2


2 Applicable layer depth HS = 28.60 2
222222222222222222222222222222222222222222

MIXING ZONE / TOXIC DILUTION / REGION OF INTEREST PARAMETERS


C0 = 0.3800E+04 CUNITS= mg/l
NTOX = 0
NSTD = 1 CSTD =0.0000E+00
REGMZ = 0
XINT = 2000.00 XMAX = 2000.00

X-Y-Z COORDINATE SYSTEM:


ORIGIN is located at the bottom and the diffuser mid-point:
1730.00 m from the RIGHT bank/shore.
X-axis points downstream, Y-axis points to left, Z-axis points upward.
NSTEP =100 display intervals per module
-----------------------------------------------------------------------------
-----------------------------------------------------------------------------
BEGIN MOD101: DISCHARGE MODULE (SINGLE PORT AT DIFFUSER CENTER)

X Y Z S C BV BH
0.00 0.00 3.13 1.0 0.380E+04 0.15 0.15

END OF MOD101: DISCHARGE MODULE (SINGLE PORT AT DIFFUSER CENTER)


-----------------------------------------------------------------------------
-----------------------------------------------------------------------------
BEGIN CORJET (MOD110): JET/PLUME NEAR-FIELD MIXING REGION

Jet/plume transition motion in weak crossflow.

Zone of flow establishment: THETAE= 60.00 SIGMAE= 90.00


LE = 1.50 XE = 0.00 YE = 0.75 ZE = 4.43

Profile definitions:
BV = Gaussian 1/e (37%) half-width, in vertical plane normal to trajectory
BH = before merging: Gaussian 1/e (37%) half-width in horizontal plane
normal to trajectory
after merging: top-hat half-width in horizontal plane
parallel to diffuser line
S = hydrodynamic centerline dilution
C = centerline concentration (includes reaction effects, if any)

X Y Z S C BV BH
Individual jet/plumes before merging:
0.00 0.75 4.43 1.0 0.380E+04 0.15 0.15
0.00 0.75 4.43 1.0 0.380E+04 0.15 0.15
0.00 0.86 4.62 1.0 0.380E+04 0.17 0.17
0.00 0.96 4.81 1.1 0.334E+04 0.20 0.20
0.00 1.07 5.01 1.3 0.293E+04 0.22 0.22
0.00 1.16 5.21 1.5 0.259E+04 0.25 0.25
0.00 1.26 5.41 1.6 0.232E+04 0.27 0.27

51
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

0.00 1.35 5.61 1.8 0.209E+04 0.29 0.29


0.00 1.44 5.82 2.0 0.189E+04 0.32 0.32
0.00 1.52 6.02 2.2 0.172E+04 0.34 0.34
0.00 1.60 6.23 2.4 0.158E+04 0.36 0.36
0.00 1.67 6.44 2.6 0.145E+04 0.38 0.38
0.00 1.75 6.65 2.8 0.134E+04 0.41 0.41
0.00 1.82 6.86 3.1 0.124E+04 0.43 0.43
0.00 1.88 7.07 3.3 0.115E+04 0.45 0.45
0.00 1.95 7.28 3.5 0.107E+04 0.48 0.48
0.00 2.01 7.50 3.8 0.100E+04 0.50 0.50
0.00 2.07 7.71 4.0 0.941E+03 0.52 0.52
0.00 2.12 7.92 4.3 0.883E+03 0.54 0.54
0.00 2.18 8.14 4.6 0.831E+03 0.57 0.57
0.00 2.23 8.36 4.9 0.783E+03 0.59 0.59
0.00 2.28 8.57 5.1 0.740E+03 0.61 0.61
0.00 2.33 8.79 5.4 0.700E+03 0.63 0.63
0.00 2.37 9.01 5.7 0.664E+03 0.66 0.66
0.00 2.42 9.22 6.0 0.630E+03 0.68 0.68
0.00 2.46 9.44 6.3 0.599E+03 0.70 0.70
0.00 2.50 9.66 6.7 0.570E+03 0.72 0.72
0.00 2.54 9.88 7.0 0.544E+03 0.75 0.75
0.00 2.58 10.09 7.3 0.519E+03 0.77 0.77
0.00 2.61 10.31 7.7 0.496E+03 0.79 0.79
0.00 2.65 10.53 8.0 0.475E+03 0.81 0.81
0.00 2.69 10.75 8.4 0.455E+03 0.83 0.83
0.00 2.72 10.97 8.7 0.436E+03 0.86 0.86
0.00 2.75 11.19 9.1 0.419E+03 0.88 0.88
0.00 2.78 11.41 9.4 0.402E+03 0.90 0.90
0.00 2.81 11.63 9.8 0.387E+03 0.92 0.92
0.00 2.84 11.85 10.2 0.372E+03 0.95 0.95
0.00 2.87 12.07 10.6 0.359E+03 0.97 0.97
0.00 2.90 12.29 11.0 0.346E+03 0.99 0.99
0.00 2.93 12.51 11.4 0.333E+03 1.01 1.01
0.00 2.96 12.73 11.8 0.322E+03 1.03 1.03
0.00 2.98 12.95 12.2 0.311E+03 1.06 1.06
0.00 3.01 13.17 12.6 0.301E+03 1.08 1.08
0.00 3.03 13.39 13.1 0.291E+03 1.10 1.10
0.00 3.06 13.61 13.5 0.282E+03 1.12 1.12
0.00 3.08 13.83 13.9 0.273E+03 1.14 1.14
0.00 3.10 14.05 14.4 0.265E+03 1.17 1.17
0.00 3.12 14.27 14.8 0.257E+03 1.19 1.19
0.00 3.15 14.49 15.3 0.249E+03 1.21 1.21
0.00 3.17 14.72 15.7 0.242E+03 1.23 1.23
0.00 3.19 14.94 16.2 0.235E+03 1.25 1.25
0.00 3.21 15.15 16.6 0.228E+03 1.28 1.28
0.00 3.23 15.37 17.1 0.222E+03 1.30 1.30
0.00 3.25 15.60 17.6 0.216E+03 1.32 1.32
0.00 3.27 15.82 18.1 0.210E+03 1.34 1.34
0.00 3.29 16.04 18.6 0.205E+03 1.36 1.36
0.00 3.30 16.26 19.1 0.199E+03 1.39 1.39
0.00 3.32 16.48 19.6 0.194E+03 1.41 1.41

52
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

0.00 3.34 16.70 20.1 0.189E+03 1.43 1.43


0.00 3.36 16.93 20.6 0.184E+03 1.45 1.45
0.00 3.37 17.15 21.1 0.180E+03 1.47 1.47
0.00 3.39 17.37 21.6 0.176E+03 1.50 1.50
0.00 3.41 17.59 22.2 0.171E+03 1.52 1.52
0.00 3.42 17.81 22.7 0.167E+03 1.54 1.54
0.00 3.44 18.03 23.2 0.164E+03 1.56 1.56
0.00 3.45 18.25 23.8 0.160E+03 1.58 1.58
0.00 3.47 18.47 24.3 0.156E+03 1.61 1.61
0.00 3.48 18.69 24.9 0.153E+03 1.63 1.63
0.00 3.50 18.91 25.4 0.149E+03 1.65 1.65
0.00 3.51 19.13 26.0 0.146E+03 1.67 1.67
0.00 3.53 19.36 26.6 0.143E+03 1.69 1.69
0.00 3.54 19.58 27.1 0.140E+03 1.72 1.72
0.00 3.55 19.80 27.7 0.137E+03 1.74 1.74
0.00 3.57 20.02 28.3 0.134E+03 1.76 1.76
0.00 3.58 20.24 28.9 0.132E+03 1.78 1.78
0.00 3.59 20.46 29.5 0.129E+03 1.80 1.80
0.00 3.61 20.68 30.1 0.126E+03 1.83 1.83
0.00 3.62 20.91 30.7 0.124E+03 1.85 1.85
0.00 3.63 21.13 31.3 0.121E+03 1.87 1.87
0.00 3.64 21.35 31.9 0.119E+03 1.89 1.89
0.00 3.66 21.57 32.5 0.117E+03 1.91 1.91
0.00 3.67 21.79 33.1 0.115E+03 1.94 1.94
0.00 3.68 22.01 33.8 0.113E+03 1.96 1.96
0.00 3.69 22.23 34.4 0.111E+03 1.98 1.98
0.00 3.70 22.46 35.0 0.108E+03 2.00 2.00
0.00 3.71 22.68 35.7 0.107E+03 2.02 2.02
0.00 3.72 22.90 36.3 0.105E+03 2.05 2.05
0.00 3.74 23.12 36.9 0.103E+03 2.07 2.07
0.00 3.75 23.34 37.6 0.101E+03 2.09 2.09
0.00 3.76 23.56 38.3 0.993E+02 2.11 2.11
0.00 3.77 23.78 38.9 0.976E+02 2.13 2.13
0.00 3.78 24.01 39.6 0.960E+02 2.16 2.16
0.00 3.79 24.23 40.3 0.944E+02 2.18 2.18
0.00 3.80 24.45 40.9 0.928E+02 2.20 2.20
0.00 3.81 24.67 41.6 0.913E+02 2.22 2.22
0.00 3.82 24.89 42.3 0.898E+02 2.24 2.24
0.00 3.83 25.11 43.0 0.884E+02 2.27 2.27
0.00 3.84 25.33 43.7 0.870E+02 2.29 2.29
0.00 3.85 25.56 44.4 0.856E+02 2.31 2.31
0.00 3.85 25.78 45.1 0.843E+02 2.33 2.33
0.00 3.86 26.00 45.8 0.830E+02 2.35 2.35
0.00 3.87 26.22 46.5 0.817E+02 2.38 2.38
Cumulative travel time = 89. sec
Merging of individual jet/plumes not found in this module, but interaction
will occur in following module. Overall jet/plume interaction dimensions:
0.00 3.87 26.22 46.5 0.817E+02 2.38 25.15

END OF CORJET (MOD110): JET/PLUME NEAR-FIELD MIXING REGION


-----------------------------------------------------------------------------

53
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

-----------------------------------------------------------------------------
BEGIN MOD232: LAYER BOUNDARY IMPINGEMENT/UPSTREAM SPREADING

Vertical angle of layer/boundary impingement = 87.68 deg


Horizontal angle of layer/boundary impingement = 90.00 deg

Discharge into STAGNANT AMBIENT environment:


STEADY-STATE MIXING CONDITION IS NOT POSSIBLE in this zone,
even though some ADDITIONAL DILUTION MAY OCCUR!
Also, all far-field processes will be UNSTEADY.
SIMULATION STOPS because of stagnant ambient conditions.

END OF MOD232: LAYER BOUNDARY IMPINGEMENT/UPSTREAM SPREADING


-----------------------------------------------------------------------------
** End of NEAR-FIELD REGION (NFR) **

SIMULATION STOPS because of STAGNANT AMBIENT conditions.


All far-field processes will be UNSTEADY.
-----------------------------------------------------------------------------
CORMIX2: Submerged Multiport Diffuser Discharges End of Prediction File
2222222222222222222222222222222222222222222222222222222222222222222222222222
2

54
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

APÉNDICE E – RESULTADOS DE CORMIX PARA EL CASO S2-0b

CORMIX SESSION REPORT:


XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXX
CORMIX: CORNELL MIXING ZONE EXPERT SYSTEM
CORMIX-GI Version 4.1G
SITE NAME/LABEL:
DESIGN CASE: Sagunto 20b
FILE NAME: C:\Documents and Settings\MARC\Escritorio\CORMIX-
GI\Sagunto\20b\Sagunto - 20b.prd
Using subsystem CORMIX1: Submerged Single Port Discharges
Start of session: 09/16/2015--10:48:52
*****************************************************************************
SUMMARY OF INPUT DATA:
-----------------------------------------------------------------------------
AMBIENT PARAMETERS:
Cross-section = unbounded
Average depth HA = 28.60 m
Depth at discharge HD = 28.60 m
Ambient velocity UA = 0 m/s
Darcy-Weisbach friction factor F = 0.0103
Calculated from Manning's n = 0.02
Wind velocity UW = 0 m/s
Stratification Type STRCND = U
Surface density RHOAS = 1027.28 kg/m^3
Bottom density RHOAB = 1027.28 kg/m^3
-----------------------------------------------------------------------------
DISCHARGE PARAMETERS: Submerged Single Port Discharge
Nearest bank = right
Distance to bank DISTB = 1730 m
Port diameter D0 = 0.3 m
Port cross-sectional area A0 = 0.0707 m^2
Discharge velocity U0 = 0.60 m/s
Discharge flowrate Q0 = 0.0425 m^3/s
Discharge port height H0 = 3.13 m
Vertical discharge angle THETA = 60 deg
Horizontal discharge angle SIGMA = 90 deg
Discharge density RHO0 = 1023.952 kg/m^3
Density difference DRHO = 3.3280 kg/m^3
Buoyant acceleration GP0 = 0.0318 m/s^2
Discharge concentration C0 = 3800 mg/l
Surface heat exchange coeff. KS = 0 m/s
Coefficient of decay KD = 0 /s
-----------------------------------------------------------------------------
DISCHARGE/ENVIRONMENT LENGTH SCALES:
LQ = 0.27 m Lm = 99999 m Lb = 99999 m
LM = 1.74 m Lm' = 99999 m Lb' = 99999 m
-----------------------------------------------------------------------------
NON-DIMENSIONAL PARAMETERS:
Port densimetric Froude number FR0 = 6.16

55
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

Velocity ratio R = 99999


-----------------------------------------------------------------------------
MIXING ZONE / TOXIC DILUTION ZONE / AREA OF INTEREST PARAMETERS:
Toxic discharge = no
Water quality standard specified = yes
Water quality standard CSTD = 0 mg/l
Regulatory mixing zone = no
Region of interest = 2000 m downstream
*****************************************************************************
HYDRODYNAMIC CLASSIFICATION:
*------------------------*
| FLOW CLASS = V5 |
*------------------------*
This flow configuration applies to a layer corresponding to the full water depth at the
discharge site.
Applicable layer depth = water depth = 28.60 m
*****************************************************************************
MIXING ZONE EVALUATION (hydrodynamic and regulatory summary):

-----------------------------------------------------------------------------
X-Y-Z Coordinate system:
Origin is located at the bottom below the port center:
1730 m from the right bank/shore.
Number of display steps NSTEP = 100 per module.
-----------------------------------------------------------------------------
NEAR-FIELD REGION (NFR) CONDITIONS :
Note: The NFR is the zone of strong initial mixing. It has no regulatory implication. However,
this information may be useful for the discharge designer because the mixing in the NFR is
usually sensitive to the discharge design conditions.
Pollutant concentration at edge of NFR = 81.2393 mg/l
Dilution at edge of NFR = 46.8
NFR Location: x=0m
(centerline coordinates) y = 3.82 m
z = 26.22 m
NFR plume dimensions: half-width = 0.15 m
thickness = 0.15 m
-----------------------------------------------------------------------------
Buoyancy assessment:
The effluent density is less than the surrounding ambient water density at the discharge level.
Therefore, the effluent is POSITIVELY BUOYANT and will tend to rise towards the surface.
-----------------------------------------------------------------------------
Near-field instability behavior:
The discharge flow will experience instabilities with full vertical mixing in the near-field.
There may be benthic impact of high pollutant concentrations.
-----------------------------------------------------------------------------
UPSTREAM INTRUSION SUMMARY:
Plume exhibits upstream intrusion due to low ambient velocity or strong discharge buoyancy.
Intrusion length = 0m
Intrusion stagnation point = 0m
Intrusion thickness = 0m
Intrusion half width at impingement = 0 m

56
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

Intrusion half thickness at impingement = 0 m


-----------------------------------------------------------------------------
FAR-FIELD MIXING SUMMARY:
Because of the specified STAGNANT ambient conditions, there exists no steady-state far-field
for this discharge. Unsteady circulations and pollutant buid-up may result in the far-field.
-----------------------------------------------------------------------------
PLUME BANK CONTACT SUMMARY:
Plume in unbounded section does not contact bank in this simulation.
************************ TOXIC DILUTION ZONE SUMMARY ************************
No TDZ was specified for this simulation.
********************** REGULATORY MIXING ZONE SUMMARY
***********************
No RMZ has been specified.
The ambient water quality standard was not encountered within the predicted plume region.
********************* FINAL DESIGN ADVICE AND COMMENTS **********************
REMINDER: The user must take note that HYDRODYNAMIC MODELING by any known
technique is NOT AN EXACT SCIENCE. Extensive comparison with field and laboratory data has
shown that the CORMIX predictions on dilutions and concentrations (with associated plume
geometries) are reliable for the majority of cases and are accurate to within about +-50%
(standard deviation). As a further safeguard, CORMIX will not give predictions whenever it
judges the design configuration as highly complex and uncertain for prediction.

57
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

CORMIX1 PREDICTION FILE:


1111111111111111111111111111111111111111111111111111111111111111111111111111
CORNELL MIXING ZONE EXPERT SYSTEM
Subsystem CORMIX1: Submerged Single Port Discharges
CORMIX-GI Version 4.1G
-----------------------------------------------------------------------------
-----------------------------------------------------------------------------
CASE DESCRIPTION
Site name/label:
Design case: Sagunto_20b
FILE NAME: C:\...scritorio\CORMIX-GI\Sagunto\20b\Sagunto - 20b.prd
Time stamp: Wed Sep 16 10:48:52 2015

ENVIRONMENT PARAMETERS (metric units)


Unbounded section
HA = 28.60 HD = 28.60
UA = 0.000 F = 0.010 USTAR =0.0000E+00
UW = 0.000 UWSTAR=0.0000E+00
Uniform density environment
STRCND= U RHOAM = 1027.2800

DISCHARGE PARAMETERS (metric units)


BANK = RIGHT DISTB = 1730.00
D0 = 0.300 A0 = 0.071 H0 = 3.13
THETA = 60.00 SIGMA = 90.00
U0 = 0.601 Q0 = 0.043 =0.4250E-01
RHO0 = 1023.9520 DRHO0 =0.3328E+01 GP0 =0.3177E-01
C0 = 0.3800E+04 CUNITS= mg/l
IPOLL = 1 KS =0.0000E+00 KD =0.0000E+00

FLUX VARIABLES (metric units)


Q0 =0.4250E-01 M0 =0.2555E-01 J0 =0.1350E-02 SIGNJ0= 1.0
Associated length scales (meters)
LQ = 0.27 LM = 1.74 Lm = 99999.00 Lb = 99999.00
Lmp = 99999.00 Lbp = 99999.00

NON-DIMENSIONAL PARAMETERS
FR0 = 6.16 R = 99999.00

FLOW CLASSIFICATION
111111111111111111111111111111111111111111
1 Flow class (CORMIX1) = V5 1
1 Applicable layer depth HS = 28.60 1
111111111111111111111111111111111111111111

MIXING ZONE / TOXIC DILUTION / REGION OF INTEREST PARAMETERS


C0 = 0.3800E+04 CUNITS= mg/l
NTOX = 0
NSTD = 1 CSTD =0.0000E+00
REGMZ = 0
XINT = 2000.00 XMAX = 2000.00

58
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

X-Y-Z COORDINATE SYSTEM:


ORIGIN is located at the bottom and below the center of the port:
1730.00 m from the RIGHT bank/shore.
X-axis points downstream, Y-axis points to left, Z-axis points upward.
NSTEP =100 display intervals per module
-----------------------------------------------------------------------------
-----------------------------------------------------------------------------
BEGIN MOD101: DISCHARGE MODULE

X Y Z S C B
0.00 0.00 3.13 1.0 0.380E+04 0.15

END OF MOD101: DISCHARGE MODULE


-----------------------------------------------------------------------------
-----------------------------------------------------------------------------
BEGIN CORJET (MOD110): JET/PLUME NEAR-FIELD MIXING REGION

Zone of flow establishment: THETAE= 60.00 SIGMAE= 90.00


LE = 1.39 XE = 0.00 YE = 0.70 ZE = 4.34

Profile definitions:
B = Gaussian 1/e (37%) half-width, normal to trajectory
S = hydrodynamic centerline dilution
C = centerline concentration (includes reaction effects, if any)

X Y Z S C B
0.00 0.00 3.13 1.0 0.380E+04 0.15
0.00 0.70 4.34 1.0 0.380E+04 0.16
0.00 0.81 4.53 1.1 0.358E+04 0.19
0.00 0.91 4.73 1.2 0.312E+04 0.21
0.00 1.01 4.92 1.4 0.275E+04 0.23
0.00 1.11 5.12 1.6 0.245E+04 0.26
0.00 1.16 5.22 1.6 0.232E+04 0.27
0.00 1.25 5.43 1.8 0.208E+04 0.29
0.00 1.34 5.63 2.0 0.189E+04 0.32
0.00 1.43 5.84 2.2 0.172E+04 0.34
0.00 1.51 6.04 2.4 0.158E+04 0.36
0.00 1.59 6.25 2.6 0.145E+04 0.39
0.00 1.66 6.46 2.8 0.134E+04 0.41
0.00 1.73 6.67 3.1 0.124E+04 0.43
0.00 1.80 6.88 3.3 0.115E+04 0.45
0.00 1.87 7.10 3.5 0.107E+04 0.48
0.00 1.93 7.31 3.8 0.100E+04 0.50
0.00 2.02 7.63 4.2 0.908E+03 0.53
0.00 2.07 7.85 4.5 0.853E+03 0.56
0.00 2.13 8.06 4.7 0.804E+03 0.58
0.00 2.18 8.28 5.0 0.758E+03 0.60
0.00 2.23 8.50 5.3 0.717E+03 0.62
0.00 2.28 8.71 5.6 0.679E+03 0.65
0.00 2.32 8.93 5.9 0.644E+03 0.67

59
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

0.00 2.37 9.15 6.2 0.612E+03 0.69


0.00 2.41 9.37 6.5 0.582E+03 0.71
0.00 2.45 9.59 6.9 0.555E+03 0.74
0.00 2.49 9.81 7.2 0.529E+03 0.76
0.00 2.53 10.03 7.5 0.505E+03 0.78
0.00 2.57 10.25 7.9 0.483E+03 0.80
0.00 2.60 10.47 8.2 0.463E+03 0.83
0.00 2.64 10.69 8.6 0.443E+03 0.85
0.00 2.67 10.91 8.9 0.425E+03 0.87
0.00 2.70 11.13 9.3 0.408E+03 0.89
0.00 2.73 11.35 9.7 0.393E+03 0.91
0.00 2.77 11.57 10.1 0.378E+03 0.94
0.00 2.80 11.79 10.4 0.364E+03 0.96
0.00 2.82 12.01 10.8 0.350E+03 0.98
0.00 2.85 12.23 11.2 0.338E+03 1.00
0.00 2.88 12.45 11.6 0.326E+03 1.03
0.00 2.91 12.67 12.1 0.315E+03 1.05
0.00 2.93 12.89 12.5 0.305E+03 1.07
0.00 2.96 13.11 12.9 0.295E+03 1.09
0.00 2.98 13.33 13.3 0.285E+03 1.11
0.00 3.01 13.56 13.8 0.276E+03 1.14
0.00 3.03 13.78 14.2 0.267E+03 1.16
0.00 3.05 14.00 14.7 0.259E+03 1.18
0.00 3.08 14.22 15.1 0.252E+03 1.20
0.00 3.10 14.44 15.6 0.244E+03 1.22
0.00 3.12 14.66 16.0 0.237E+03 1.25
0.00 3.14 14.88 16.5 0.230E+03 1.27
0.00 3.16 15.11 17.0 0.224E+03 1.29
0.00 3.18 15.33 17.4 0.218E+03 1.31
0.00 3.20 15.55 17.9 0.212E+03 1.34
0.00 3.22 15.77 18.4 0.206E+03 1.36
0.00 3.24 15.99 18.9 0.201E+03 1.38
0.00 3.26 16.21 19.4 0.196E+03 1.40
0.00 3.27 16.44 19.9 0.191E+03 1.42
0.00 3.29 16.66 20.4 0.186E+03 1.45
0.00 3.31 16.88 21.0 0.181E+03 1.47
0.00 3.33 17.10 21.5 0.177E+03 1.49
0.00 3.34 17.32 22.0 0.173E+03 1.51
0.00 3.36 17.55 22.5 0.169E+03 1.53
0.00 3.37 17.77 23.1 0.165E+03 1.56
0.00 3.39 17.99 23.6 0.161E+03 1.58
0.00 3.41 18.21 24.2 0.157E+03 1.60
0.00 3.42 18.43 24.7 0.154E+03 1.62
0.00 3.44 18.66 25.3 0.150E+03 1.64
0.00 3.45 18.88 25.8 0.147E+03 1.67
0.00 3.46 19.10 26.4 0.144E+03 1.69
0.00 3.48 19.32 27.0 0.141E+03 1.71
0.00 3.49 19.55 27.6 0.138E+03 1.73
0.00 3.51 19.77 28.2 0.135E+03 1.76
0.00 3.52 19.99 28.7 0.132E+03 1.78
0.00 3.53 20.21 29.3 0.130E+03 1.80

60
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

0.00 3.55 20.43 29.9 0.127E+03 1.82


0.00 3.56 20.66 30.5 0.124E+03 1.84
0.00 3.57 20.88 31.1 0.122E+03 1.87
0.00 3.58 21.10 31.8 0.120E+03 1.89
0.00 3.59 21.32 32.4 0.117E+03 1.91
0.00 3.61 21.55 33.0 0.115E+03 1.93
0.00 3.62 21.77 33.6 0.113E+03 1.95
0.00 3.63 21.99 34.3 0.111E+03 1.98
0.00 3.64 22.21 34.9 0.109E+03 2.00
0.00 3.65 22.44 35.5 0.107E+03 2.02
0.00 3.66 22.66 36.2 0.105E+03 2.04
0.00 3.68 22.88 36.8 0.103E+03 2.06
0.00 3.69 23.10 37.5 0.101E+03 2.09
0.00 3.70 23.32 38.1 0.996E+02 2.11
0.00 3.71 23.55 38.8 0.979E+02 2.13
0.00 3.72 23.77 39.5 0.963E+02 2.15
0.00 3.73 23.99 40.1 0.946E+02 2.17
0.00 3.74 24.21 40.8 0.931E+02 2.20
0.00 3.75 24.44 41.5 0.915E+02 2.22
0.00 3.76 24.66 42.2 0.901E+02 2.24
0.00 3.77 24.88 42.9 0.886E+02 2.26
0.00 3.78 25.10 43.6 0.872E+02 2.29
0.00 3.79 25.33 44.3 0.858E+02 2.31
0.00 3.80 25.55 45.0 0.845E+02 2.33
0.00 3.81 25.77 45.7 0.831E+02 2.35
0.00 3.81 25.99 46.4 0.819E+02 2.37
0.00 3.82 26.22 46.8 0.812E+02 2.38
Cumulative travel time = 90. sec

END OF CORJET (MOD110): JET/PLUME NEAR-FIELD MIXING REGION


-----------------------------------------------------------------------------
-----------------------------------------------------------------------------
BEGIN MOD132: LAYER BOUNDARY IMPINGEMENT/UPSTREAM SPREADING

Vertical angle of layer/boundary impingement = 87.69 deg


Horizontal angle of layer/boundary impingement = 90.00 deg

Discharge into STAGNANT AMBIENT environment:


STEADY-STATE MIXING CONDITION IS NOT POSSIBLE in this zone,
even though some ADDITIONAL DILUTION MAY OCCUR!
Also, all far-field processes will be UNSTEADY.
SIMULATION STOPS because of stagnant ambient conditions.

END OF MOD132: LAYER BOUNDARY IMPINGEMENT/UPSTREAM SPREADING


-----------------------------------------------------------------------------
** End of NEAR-FIELD REGION (NFR) **

SIMULATION STOPS because of STAGNANT AMBIENT conditions.


All far-field processes will be UNSTEADY.
-----------------------------------------------------------------------------

61
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

CORMIX1: Submerged Single Port Discharges End of Prediction File


1111111111111111111111111111111111111111111111111111111111111111111111111111
1

62
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

APÉNDICE F – RESULTADOS DE CORMIX PARA EL CASO S2-3


CORMIX SESSION REPORT:
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXX
CORMIX: CORNELL MIXING ZONE EXPERT SYSTEM
CORMIX Version 9.0E
SITE NAME/LABEL:
DESIGN CASE: Sagunto 20b
FILE NAME: C:\Documents and Settings\MARC\Escritorio\CORMIX-
GI\Sagunto\21\Sagunto - 21.prd
Using subsystem CORMIX1: Multiport Diffuser Discharges
Start of session: 09/16/2015--12:48:52
*****************************************************************************
SUMMARY OF INPUT DATA:
-----------------------------------------------------------------------------
AMBIENT PARAMETERS:
Cross-section = unbounded
Average depth HA = 28.60 m
Depth at discharge HD = 28.60 m
Ambient velocity UA = 0.3 m/s
Darcy-Weisbach friction factor F = 0.0103
Calculated from Manning's n = 0.02
Wind velocity UW = 0 m/s
Stratification Type STRCND = U
Surface density RHOAS = 1027.28 kg/m^3
Bottom density RHOAB = 1027.28 kg/m^3
-----------------------------------------------------------------------------
DISCHARGE PARAMETERS: Submerged Multiport Diffuser Discharge
Diffuser type DITYPE = Unidirectional parallel
Diffuser length LD = 375 m
Nearest bank = right
Diffuser endpoints YB1 = 1730 m; YB2 = 1730 m
Number of openings………………..NOPEN = 16
Number of risers NRISER = 1
Ports/nozzles per riser NPERR = 1
Spacing between risers/openings SPAC = 25
Port/Nozzle diameter D0 = 0.3 m
With contraction ratio =1
Equivalent slot width B0 = 0.0030 m
Total area of openings TAO = 1.1310 m^2
Discharge velocity U0 = 0.60 m/s
Total discharge flowrate Q0 = 0.6794 m^3/s
Discharge port height H0 = 3.13 m
Nozzle arrangement BETYPE = unidirectional without fanning
Diffuser alignment angle GAMMA = 0 deg
Vertical discharge angle THETA = 60 deg
Actual vertical discharge angle THEAC = 60 deg
Horizontal discharge angle SIGMA = 90 deg
Relative orientation angle BETA = 90 deg
Discharge density RHO0 = 1023.952 kg/m^3

63
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

Density difference DRHO = 3.3280 kg/m^3


Buoyant acceleration GP0 = 0.0318 m/s^2
Discharge concentration C0 = 3800 mg/l
Surface heat exchange coeff. KS = 0 m/s
Coefficient of decay KD = 0 /s
-----------------------------------------------------------------------------
FLUX VARIABLES PER UNIT DIFFUSER LENGTH
Discharge (volume flux) q0 = 0.001812 m^2/s
Momentum flux m0 = 0.001088 m^3/s^2
Buoyancy flux j0 = 0.000058 m^3/s^3
-----------------------------------------------------------------------------
DISCHARGE/ENVIRONMENT LENGTH SCALES:
LQ = 0.00 m Lm = 0.01 m Lb = 0.73 m
lm' = 99999 m Lb' = 99999 m La = 99999 m
(These refer to the actual discharge/environment length scales.)
-----------------------------------------------------------------------------
NON-DIMENSIONAL PARAMETERS:
Slot Froude number FR0 = 61.35
Port/Nozzle Froude number FRD0 = 6.15
Velocity ratio R = 2.00
-----------------------------------------------------------------------------
MIXING ZONE / TOXIC DILUTION ZONE / AREA OF INTEREST PARAMETERS:
Toxic discharge = no
Water quality standard specified = yes
Water quality standard CSTD = 0 mg/l
Regulatory mixing zone = no
Region of interest = 2000 m downstream
*****************************************************************************
HYDRODYNAMIC CLASSIFICATION:
*------------------------*
| FLOW CLASS = MU1H |
*------------------------*
This flow configuration applies to a layer corresponding to the full water depth at the
discharge site.
Applicable layer depth = water depth = 28.60 m
*****************************************************************************
MIXING ZONE EVALUATION (hydrodynamic and regulatory summary):

-----------------------------------------------------------------------------
X-Y-Z Coordinate system:
Origin is located at the BOTTOM below the port/diffuser center:
1730 m from the right bank/shore.
Number of display steps NSTEP = 100 per module.
-----------------------------------------------------------------------------
NEAR-FIELD REGION (NFR) CONDITIONS :
Note: The NFR is the zone of strong initial mixing. It has no regulatory implication. However,
this information may be useful for the discharge designer because the mixing in the NFR is
usually sensitive to the discharge design conditions.
Pollutant concentration at edge of NFR = 0.9998 mg/l
Dilution at edge of NFR = 3800.9
NFR Location: x = 507.40 m

64
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

(centerline coordinates) y = 1.63 m


z = 28.60 m
NFR plume dimensions: half-width = 151.29 m
thickness = 28.60 m
Cumulative travel time: 2329.0627 sec.
-----------------------------------------------------------------------------
Buoyancy assessment:
The effluent density is less than the surrounding ambient water density at the discharge level.
Therefore, the effluent is POSITIVELY BUOYANT and will tend to rise towards the surface.
-----------------------------------------------------------------------------
FAR-FIELD MIXING SUMMARY:
Plume is vertically fully mixed WITHIN NEAR- FIELD (or a fraction thereof), but RE-STRATIFIES
LATER.
Plume becomes vertically fully mixed again at 1372.77 m downstream.
-----------------------------------------------------------------------------
PLUME BANK CONTACT SUMMARY:
Plume in unbounded section does not contact bank in this simulation.
************************ TOXIC DILUTION ZONE SUMMARY ************************
No TDZ was specified for this simulation.
********************** REGULATORY MIXING ZONE SUMMARY
***********************
No RMZ has been specified.
The ambient water quality standard was not encountered within the predicted plume region.
********************* FINAL DESIGN ADVICE AND COMMENTS **********************
CORMIX2 uses the TWO=DIMENSIONAL SLOT DIFFUSER CONCEPT to represent the actual
three=dimensional diffuser geometry. Thus, it approximates the details of the merging process
of the individual jets from each port/nozzle.
In the present design, the spacing between adjacent ports/nozzles (or riser assemblies) is of
the order of, or less than, the local water depth so that the slot diffuser approximation holds
well.
Nevertheless, if this is a final design, the user is advised to use a final CORMIX1 (single port
discharge) analysis, with discharge data for an individual diffuser jet/plume, in order to
compare to the present near-field prediction.
-----------------------------------------------------------------------------
REMINDER: The user must take note that HYDRODYNAMIC MODELING by any known
technique is NOT AN EXACT SCIENCE.
Extensive comparison with field and laboratory data has shown that the CORMIX predictions
on dilutions and concentrations (with associated plume geometries) are reliable for the
majority of cases and are accurate to within about +-50% (standard deviation).
As a further safeguard, CORMIX will not give predictions whenever it judges the design
configuration as highly complex and uncertain for prediction.

65
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

CORMIX2 PREDICTION FILE:


2222222222222222222222222222222222222222222222222222222222222222222222222222
2
CORNELL MIXING ZONE EXPERT SYSTEM
Subsystem CORMIX2: Multiport Diffuser Discharges
CORMIX-GI Version 9.0E
HYDRO2 Version 9.0.0.0 September 2014
------------------------------------------------------------------------------------------------------------------------------
------------------------------------------------------------------------------------------------------------------------------
CASE DESCRIPTION
Site name/label:
Design case: Sagunto_21
FILE NAME: C:\...\Escritorio\CORMIX-GI\Sagunto\21\Sagunto - 21.prd
Time stamp: Wed Sep 16 12:59:56 2015

ENVIRONMENT PARAMETERS (metric units)


Unbounded section
HA = 28.60 HD = 28.60
UA = 0.300 F = 0.010 USTAR =0.1075E-01
UW = 0.000 UWSTAR=0.0000E+00
Uniform density environment
STRCND= U RHOAM = 1027.2800

DIFFUSER DISCHARGE PARAMETERS (metric units)


Diffuser type: DITYPE= unidirectional_parallel
BANK = RIGHT DISTB = 1730.00 YB1 = 1730.00 YB2 = 1730.00
LD = 375.00 NOPEN = 16 SPAC = 25.00
D0 = 0.300 A0 = 0.071 H0 = 3.13 SUB0 = 25.47
DOINP = 0.300 CR0 = 1.000
Nozzle/port arrangement: unidirectional_without_fanning
GAMMA = 0.00 THETA = 60.00 SIGMA = 90.00 BETA = 90.00
U0 = 0.601 Q0 = 0.679 =0.6794E+00
RHO0 = 1023.9500 DRHO0 =0.3330E+01 GP0 =0.3179E-01
C0 = 0.3800E+04 CUNITS= mg/l
IPOLL = 1 KS =0.0000E+00 KD =0.0000E+00

FLUX VARIABLES - PER UNIT DIFFUSER LENGTH (metric units)


q0 =0.1812E-02 m0 =0.1088E-02 j0 =0.5759E-04 SIGNJ0= 1.0
Associated 2-d length scales (meters)
lQ=B = 0.003 lM = 0.73 lm = 0.01
lmp = 99999.00 lbp = 99999.00 la = 99999.00

FLUX VARIABLES - ENTIRE DIFFUSER (metric units)


Q0 =0.6794E+00 M0 =0.4081E-00 J0 =0.2160E-01
Associated 3-d length scales (meters)
LQ = 0.27 LM = 3.47 Lm = 2.13 Lb = 0.80
Lmp = 99999.00 Lbp = 99999.00

NON-DIMENSIONAL PARAMETERS
FR0 = 61.35 FRD0 = 6.15 R = 2.00 PL = 599.80
(slot) (port/nozzle)

66
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

RECOMPUTED SOURCE CONDITIONS FOR RISER GROUPS:


Properties of riser groups with 1 ports/nozzles each:
U0 = 0.601 D0 = 0.300 A0 = 0.071 THETA = 60.00
FR0 = 61.35 FRD0 = 6.15 R = 2.00
(slot) (riser group)

FLOW CLASSIFICATION
222222222222222222222222222222222222222222
2 Flow class (CORMIX2) = MU1H 2
2 Applicable layer depth HS = 28.60 2
222222222222222222222222222222222222222222

MIXING ZONE / TOXIC DILUTION / REGION OF INTEREST PARAMETERS


C0 = 0.3800E+04 CUNITS= mg/l
NTOX = 0
NSTD = 1 CSTD =0.0000E+00
REGMZ = 0
XINT = 2000.00 XMAX = 2000.00

X-Y-Z COORDINATE SYSTEM:


ORIGIN is located at the bottom and the diffuser mid-point:
1730.00 m from the RIGHT bank/shore.
X-axis points downstream, Y-axis points to left, Z-axis points upward.
NSTEP =100 display intervals per module
------------------------------------------------------------------------------------------------------------------------------
------------------------------------------------------------------------------------------------------------------------------
BEGIN MOD101: DISCHARGE MODULE (SINGLE PORT AT DIFFUSER CENTER)

X Y Z S C BV BH Uc TT
0.00 0.00 3.13 1.0 0.380E+04 0.15 0.15 0.601 .00000E00

END OF MOD101: DISCHARGE MODULE (SINGLE PORT AT DIFFUSER CENTER)


------------------------------------------------------------------------------------------------------------------------------
------------------------------------------------------------------------------------------------------------------------------
BEGIN CORJET (MOD110): JET/PLUME NEAR-FIELD MIXING REGION

Jet/plume transition motion in strong crossflow.

Zone of flow establishment: THETAE= 58.01 SIGMAE= 67.54


LE = 0.00 XE = 0.00 YE = 0.00 ZE = 3.13

Profile definitions:
BV = Gaussian 1/e (37%) half-width, in vertical plane normal to trajectory
BH = before merging: Gaussian 1/e (37%) half-width in horizontal plane
normal to trajectory
after merging: top-hat half-width in horizontal plane
parallel to diffuser line
S = hydrodynamic centerline dilution
C = centerline concentration (includes reaction effects, if any)
Uc = Local centerline excess velocity (above ambient)

67
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

TT = Cumulative travel time

68
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

69
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

70
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

71
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

72
Estudio de dilución del vertido de aguas residuales procedente
del futuro emisario de Sagunto

73

You might also like