You are on page 1of 1

Sheet1

2 -PILE-GROUP
S = 1200

AS2
W=
700 B/2
B

L/2 AS1

L= 1900 PILE SIZE ( dia.)= 400 MM.SQ.

av PILE SPACING ( S ) = 1200 MM


Soffit of beam or slab
H= 800 MM

B= 800 MM

fcu = 35 N/MM2
AS1
d D use fy = 460 N/MM2
COL 1500
AS1 use 16 MM dia. bar
75
125 AS2 use 16 MM dia. bar
AS2
( D ) MINIMUM 900 MM
T13-250 50 LEAN CONCRETE D use 1500 MM

400 PILE WORKING LOAD ( WL ) = 1360 KN


PLAN AND SECTION
MINIMUM DEPTH OF PILE CAP ( D )

IF dia. < = 550 MM THAN D = 2.dia.+100 = 900 MM

IF DIA. > 550 MM THAN D = 1/3 ( 8.dia. - 600 ) = NA MM

d= 1375 MM

L = ( S / dia. + 1 )dia. + 300 = 1900 MM

W = dia. + 300 = 700 MM

ULTIMATE LOAD ( N ) = 2 x 1.5.WL = 4080 KN

REYNOLDS DESIGNER'S HANDBOOK - TRUSS STSTEM


TENSILE FORCE ( T ) = N ( 3S^2 - H^2 ) / 12.S.d = 758 KN

Minimum AS1 = 0.15%.W.D = 1575 MM2


AS1 required = T / 0.87.FY = 1895 MM2
OK - MORE THAN AS1. Minimum
Required 9.42 NOS. T 16
AS1 use : 32 T 16

FILE : 2PILEG