Professional Documents
Culture Documents
ENDRESS -
Innovative energy
of a strong brand
In 94 years of existence, ENDRESS has specialized in the development, construction and sale of first-class
power generators. With innovation and new products of technical excellence ENDRESS will set the trend
and secure its leading position also in future.
Innovative strength and customized product development as well as professional guidance in application
are the parameters of a service-oriented corporate philosophy. In this way, ENDRESS meets the growing
requirements and the internationalization of business also in future.
Product Catalog
Engine pumps
DUPLEX-G4 technology
• OHV engines from HONDA.
• Brushless synchronous generator with electronic
voltage regulation. Site generators
• Highest protection: IP 54.
• DEUTZ oil/water cooled industrial engines.
• Maintenance-free for 20,000 generator hours,
wear and maintenancefree due to inductive transmission. • Synchronous generators with electronic voltage regulation.
Mobile floodlight systems
DUPLEX-G5 technology
• Slows down the engine to the lowest possible • Safe, reliable, long-lived.
2008
speed in idle running. • Fully hot dip galvanized chassis, turn 360° degs.
• Restart at full load from the beginning. • Telescopic posts for mechanical or pneumatic extension.
• Substantial reduction of noise level in idle running. Power supply systems
• Up to 25 % less fuel consumption.
• DEUTZ oil/water cooled industrial engines.
Mobile generators • VOLVO-Penta water-cooled industrial engines.
• Extremely long-lived OHV engines.
• Robust, long-lived diesel engines.
• Site-optimized generator equipment
3
with compound regulator – 400 V and higher.
26
44
Made by ENDRESS -
a success story
1970 1980 1985 1990
Electric and engine Permanently installed Permanently installed Vertical generators
welding units and mobile welding and noise-controlled from 1 – 3 kVA
from 50 – 240 A generators large mobile units
from 170 – 400 A of 1500 rpm
ENDRESS TRIPLEX technology
• For global use
• Conforms with VSCF (variable speed
constant frequency) technology
• Constant voltage and frequency
- Unrelated to engine speed
- The optimal efficiency
of the engine is used
• Substantial reduction of pollution
and noise emission
• Very economical due to low cost
INNOVATION
of operation
ENDRESS
Efficiency
Optimal efficiency
ENDRESS TRIPLEX technology
Speed 55
Future-proof technology with in-house development and production
ENDRESS is among the leading European suppliers of power generators. Decades of experience in the development and production of
power generators ensure highest quality and absolute reliability. With an output range of up to 2000 kVA, ENDRESS supplies all needs.
Innovative units for fire brigades, emergency management and rescue services or the supply of products bound to certain projects are
part of the range, as are floodlight systems and emergency power generators.
Powerful tools
and circular saws
Light and
VKS-Technologie = lighting systems
Verschleißfrei · Kontaktlos
S törungsfrei
DUPLEX
M G E
Site and waste
sewage pumps
INNOVATION
ENDRESS
Miniature crane
or cement machine
Where large
and heavy units
used to work … … today, DUPLEX
technology proves
its competence.
This is the Duplex difference: before the engine is overloaded. Hidden The subtle difference
In the days where there was no electro- power reserves can be tapped and the Where conventional machines still have
nics, an asynchronous generator was DUPLEX generator “pushes up” even the carbon brushes, which are subject to
needed to be able to achieve “smooth” heaviest inductive consumers and protects wear and tear, the ENDRESS DUPLEX
electricity and synchronous generators even sensitive consumers from damage. system has an intelligent exciter machine.
to tackle “heavy” electricity. In combination with the power electronic
In this way all the advantages of asyn- assemblies, it marks the peak of modern
With the DUPLEX technology, the electro- chronous and synchronous alternators power generation technology.
nic control module adapts to the drive are combined in a single product, and the
engine and responds correspondingly differences are not needed anymore.
DUPLEX-G5 technology
Why speed reduction? ENDRESS DUPLEX-G5 speed reduction by comparison
Most generators do not run at constant load all the time but there
are times of idling in between. Power is withdrawn as and when needed, r.p.m Full-load phase Idle phase Full-load phase
Spee
mechanical/manual
available on call. speed reduction
d red
uction
phase
Points for the DUPLEX-G5 technology ENDRESS DUPLEX-G5
speed reduction
• Slows down the engine to the lowest possible speed in idle running.
• Restarts at full load from the beginning. ENDRESS DUPLEX-G5 technology
INNOVATION
• Less emission of pollutants.
• Life is extended several times over.
ENDRESS
The new E-MSC 3.0 at a glance
The perfect Multifunction Control System (MSC) from ENDRESS. Option: CanBus linkup
A system for optimal safety and user friendliness for everyday The link between the unit and the customer’s operator panel is
use. CanBus capability included as standard. provided by a control interface unit (CIU). Before data can be
exchanged, some customization must be made at the ENDRESS
factory.
Icon Run hours
Icon Ambient temperature1 Icon Engine temperature1
Function Total run hours of the engine/generator
Function Measures the direct ambient Function Measures the engine temperature
Display LED
temperature Display LED
Display LED
Red = Ambient temperature too high
Red = Engine temperature too high
7
Icon Oil pressure
P icon Load Function Measures the oil pressure Icon Fuel temperature1
Function Phases 1-3 load Display LED Function Measures the fuel temperature
Display LED Red = Oil pressure fault Display LED
Green = 0 to 80% Red = Fuel temperature too high
Yellow = 81 to 100%
Red = 101 to 110%
Icon Rotating field
Function Status of the rotating field
(cw or ccw)
Display LED
Red blinking = ccw rotation
Icon Emergency stop
Icon Battery charge indicator
Function Emergency stop enabled
Function Charge function of the
Display LED
alternator has failed
Red = Emergency stop
Display LED
has been pressed
Red = Fault
P icon Phase voltage
Function Indicates voltage Icon Iso3
of phases 1-3 Function Isolation fault
Display LEDs Display LED
Red = high (undervoltage) Yellow = Half fault
Green = voltage OK Red = Fault
Red = low (overvoltage)
Icon Protective conductor check
Icon Function Protective conductor of the
L1 = Phase 1 connected unit is checked
L2 = Phase 2 Display LED
L3 = Phase 3 Green = OK
Verify prior to any start-up that the overall When to use a high-speed and when a low-speed engine?
output of the unit to be connected does The correct decision.
not exceed that of the nominal continuous
output of the generator. The required High-speed engine (OHV petrol and diesel engines of 3000 rpm)
information can be found on the name- • Engines for daily operation of 4 - 10 hours.
plate or in the product booklet of the Life = service life between 3000 and 5000 hrs.
consumer. (e.g., building sites, craft businesses)
At a glance
Performance data often indicate the maximum output of the engine without load on the
crankshaft = SAE HP, usually at 3600 rpm. For electrotechnical reasons all high-speed
engines must run at 3000 rpm. Hence, the output is lower even if no load is connected.
Synchronous Asynchronous
Application All ohmic and inductive consumers. Only ohmic consumers without restrictions.
Inductive consumers with considerable restrictions.
Start up reaction Unproblematic start up reaction, irrespective of the consumer. Problematic start up reaction with consumers which are difficult
Compound regulatored alternators with 3 times the start up current. to start, particularly with alternators which do not have a
Duplex alternators with 4 times the start up current. strengthened start up. A large generator is required for alternators
with a strengthened start up.
Loading capacity The alternator can also be loaded up to 100% by inductive The alternator can only be loaded up to 1/3 (without strengthened
consumers and can therefore be smaller. start up) and 2/3 (with strengthened start up) by inductive consumers.
Regulator Mechanical regulator IP23. Electronic regulator IP54. Normally unregulated, capacitor.
Type of protection Determined by internal cooler IP 23. Determined by the external cooler IP 54.
Determined by external cooler IP 54.
Protective measures Fuse disconnections as protection for user. Fuse disconnections as protection for user.
RCD protection switch not necessary. RCD protection switch not necessary.
Differences
in consumers
In this case, the consumers concerned are machines which do In this case, the consumers concerned are machines which
not require any start up current, i.e., consumers whose power require a multiplicity of power indicated only for a short time
consumption does not increase up to the normal operating during the moment of starting.
condition in the moment of ignition. Start-up current = opera-
ting current. Particularly electric motors require 2-6 times the given value
The consumption data of these machines can be used without for the build up of the magnetic field as well as for the accele-
making any additions. ration to the working speed.
I N F O R M AT I O N
GENERATORS
* * * *
9
Types of protection
Why are they so important? IP = International protection according to DIN 40050
60°
Electrical machines must be protected The IP code is a two-digit number which indicates the type of protection.
from moisture and dirt to be able to The first digit specifies the protection class for shock and ingress of solid
function properly. ENDRESS generators foreign bodies, the second digit indicates the protection against water and
work to the protection measure/protection moisture.
separation VDE 0100. The protection
separation divides the supply line of a
connected unit from the storing network. IP 23 0 Unprotected 0 Unprotected
In this way a situation of a closed electric 1 Foreign bodies > 50 mm 1 Vertical dripping
circuit can be prevented by the ground. 2 Foreign bodies > 12 mm 2 Dripping at up to 15°
Therefore the installation of grounding 3 Foreign bodies > 2.5 mm from vertical
can be avoided. 4 Foreign bodies > 2.5 mm 3 Water spray at up to 60°
5 Protected against dust from vertical
4 Splash water from
all directions
5 Hose water from
IP 54 all directions
Explanations,
Specifications
and what they mean
Explanation of the abbreviations in the tables COP = Continuous power of the unit
Continuous power in full power
V = Volts Voltage (230/400/115)
application without a time limit.
Hz = Hertz Frequency (50/60)
A = Ampere Amperage
PRP = Variable continuous power
W = Watt (x 1000 = kW) Active power
of the unit
VA = Volt x Amperes (x 1000 = kVA) Power factor
Continuous power in a varying load
Cos phi = Physical power factor Power factor (0.8 - 1)
operation (average 80% load within
24 hrs.) without time limit.
Apparent power - indicated in units of VA or kVA
I N F O R M AT I O N
GENERATORS
GENERATOR PROFILE
DUPLEX
M G M G E TRI-
PLEX
M G
ENDRESS
• Class of protection IP 23 against water spray. • Brushless synchronous generator IP 54, • Conforms with VSCF technology.
• Maintenance-free. with electronic voltage regulation. • Constant voltage and frequency unrelated to
• Can withstand start-up current for a short time. • Start-up performance 60% higher than engine speed.
• Compound-controlled high-performance gene- conventional generators. • Substantial reduction of pollution and noise
rator suitable for 3 times overload from 400 V. • 100% constant voltage in spite emission.
• Smooth voltage shape. of varying speed. • Very economical due to low cost of operation.
• Suitable for 200% load unbalance. • Smaller and with higher output.
• 20000 generator hours.
• VKS technology.
Duplex-G5 technology
Engine
• Petrol or diesel.
• Easy starting by recoil starter.
• Modern OHV design.
Less petrol consumption.
Less oil consumption.
• Low oil cutoff.
• Contactless transistor ignition.
• Simple handling.
12
The concept of the future in the …and suitable for all applications. • TRIPLEX technology.
mobile generator market: Most advanced generator technology • Intelligent engine management.
compact, lightweight, low noise, supplies highest output and current whose • Constant power output.
powerful… quality compares to that of the public • Stable and exact parameters.
mains. The intelligent engine management • Low-noise and economical.
controls the engine speed as function of • Easy starting with most advanced
the load which reduces fuel consumption engine technology.
and noise. Constant power output is a • Light-weight and compact.
particular advantage for electronic cons- • Long service life.
umers and consumers with start-up • Simple and safe to handle.
current. • Complies with all norms.
Mobile power generation on highest level.
For boats, camping and events, high cost effectiveness.
G E N E R AT O R S
SILENT-LINE
ESE 4500 T Silent
M G
Type
Order No.
ESE 2000 T Silent
110 000
ESE 3500 T Silent
110 001
ESE 4500 T Silent
110 002
13
Alternator synchronous synchronous synchronous
Max. output [LTP] kVA/kW 1,65/1,65 3,2/3,2 4,3/4,3
Constant rating [COP] kVA/kW 1,35/1,35 2,8/2,8 3,8/3,8
Nominal voltage 230 V 1~/12 V = 230 V 1~/12 V = 230 V 1~/12 V =
Nominal current/cos (phi) 5,8 A 1~/8,3 A =/1 12,1 A 1~/8,3 A =/1 16,5 A 1~/8,3 A =/1
Frequency/Type of protection 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23
Voltage regulation electronic electronic electronic
Engine type ROBIN EH09 ROBIN EX21 ROBIN EX27
Version 1-cyl. 4-stroke OHV 1-cyl. 4-stroke 1-cyl. 4-stroke
Engine capacity 86 cm3 212 cm3 265 cm3
Max. output 2,1 kW/2,9 HP 5,1 kW/7 HP 6,6 kW/9 HP
Fuel/Tank capacity (litres) Unleaded petrol/4 Unleaded petrol/10,8 Unleaded petrol/12,8
Consumption/Running-time1 0,7 l/6 h 1,4 l/6,5 h 1,8 l/7 h
Start-up system Recoil E-start incl. battery E-start incl. battery
Sound power level LWA2 90 dB(A) 91 dB(A) 91 dB(A)
Sound pressure level LPA3 65 dB(A) 66 dB(A) 66 dB(A)
Weight kg 21 59 74
Dimensions L x W x H in mm 490 x 295 x 445 537 x 482 x 583 580 x 527 x 618
Outfit 2 x 230 V/16 A 2 x 230 V/16 A 2 x 230 V/16 A
Shockproof sockets Operating control lamps Digital display Digital display
Cut-off when lack of oil, load-dependent engine speed, overload protection, connection for 12 V battery charge
Application areas* 230 V 230 V 230 V
Appliances up to 1350 W 2800 W 3800 W
PC/Multimedia up to 1350 W 2800 W 3800 W
Electric tools up to 1200 W 2600 W 3600 W
Gardening equipment up to 1000 W 1900 W 2500 W
Construction equipment up to 1400 W 1900 W
1
Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation.
2
Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m.
* As the power needs of each consumer are influenced by various factors, no claims can be derived from this table.
Classic Power Line
generators
1.6 - 2.9 kVA
CLASSIC POWER-LINE
G E N E R AT O R S
26
18
14
ESE 30 BS
All-round generators for electrical The portable ENDRESS generators of this type series are equipped with
equipment, power tools, gardening HONDA engines as well as with high-performance synchronous generators.
equipment and lighting. A sturdy monobloc tube frame with large side panels protects engine and
generator (except ESE 20 BS). Low oil cut-off and overload protection
belong to standard outfit.
Classic Power-Line quality
generators, which convince
CLASSIC POWER-LINE
in performance and price.
ESE 20 BS
G E N E R AT O R S
ESE 3000
ESE 40 BS
• 11-18 liter tank for long run hours. Compressors, pumps up to 1300 W 1300 W
1
Consumption/litres in hours, running-time in hours. These indications are based on approx. values
2
Sound level indication according to the directive for noise emission law 2000/14/EG.
* As the power needs of each consumer are influenced by various factors, no claims can be derived
For demanding users. ESE 606 HS-GT
PROFESSIONAL-GT-LINE
Mature technology and solid construction:
the Professional GT line
G E N E R AT O R S
ESE 506 DHS-GT
ESE 406 HS-GT ESE 406 HS-GT ES ESE 506 DHS-GT ESE 606 HS-GT ESE 606 DHS-GT ESE 606 DHS-GT ES
17
112 001 112 009 112 003 112 002 112 004 112 008
synchronous synchronous synchronous synchronous synchronous synchronous
5,1/4,6 5,1/4,6 6,3/5,0 4,2/3,7 7,2/6,4 8,3/6,6 5,5/4,9 8,3/6,6 5,5/4,9
4,2/3,9 4,2/3,9 5,4/4,3 3,1/2,8 6,0/5,4 7,0/5,6 4,1/3,7 7,0/5,6 4,1/3,7
230 V 1~ 230 V 1~ 400 V 3~ 230 V 1~ 230 V 1~ 400 V 3~ 230 V 1~ 400 V 3~ 230 V 1~
18,3 A 1~ 18,3 A 1~ 7,7 A 3~ 13,5 A 1~ 26,1 A 1~ 10,1 A 3~ 17,8 A 1~ 10,1 A 3~ 17,8 A 1~
0,9 0,9 0,8 0,9 0,9 0,8 0,9 0,8 0,9
50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23
HONDA GX 270 HONDA GX 270 HONDA GX 270 HONDA GX 390 HONDA GX 390 HONDA GX 390
1-cyl. 4-stroke OHV 1-cyl. 4-stroke OHV 1-cyl. 4-stroke OHV 1-cyl. 4-stroke OHV 1-cyl. 4-stroke OHV 1-cyl. 4-stroke OHV
270 cm3 270 cm3 270 cm3 389 cm3 389 cm3 389 cm3
6,3 kW/8,6 HP 6,3 kW/8,6 HP 6,3 kW/8,6 HP 8,3 kW/11,3 HP 8,3 kW/11,3 HP 8,3 kW/11,3 HP
Unleaded petrol/18 Unleaded petrol/18 Unleaded petrol/18 Unleaded petrol/18 Unleaded petrol/18 Unleaded petrol/18
1,1 l/10 h 1,6 l/11 h 1,6 l/11 h 1,6 l/11 h 2,2 l/8 h 2,1 l/8,5 h 2,1 l/8,5 h
Recoil E-start incl. battery Recoil Recoil Recoil E-start incl. battery
97 dB(A) 97 dB(A) 97 dB(A) 97 dB(A) 97 dB(A) 97 dB(A)
72 dB(A) 72 dB(A) 72 dB(A) 72 dB(A) 72 dB(A) 72 dB(A)
62 66 76 74 82 90
832 x 513 x 570 832 x 513 x 570 832 x 513 x 570 832 x 513 x 570 832 x 513 x 570 832 x 513 x 570
2 x 230 V/16 A 2 x 230 V/16 A 1 x 230 V/16 A 1 x 230 V/16 A 1 x 230 V/16 A 1 x 230 V/16 A
1 x CEE 400 V/16 A 1 x CEE 230 V/32 A 1 x CEE 400 V/16 A 1 x CEE400 V/16 A
NEW NEW
18 Type
Order No.
Alternator
ESE 1006 DBS-GT
112 023
synchronous
ESE 1006 DBS-GT ES
112 024
synchronous
ESE 1206 HS-GT ES
112 021
synchronous
ESE 1206 DHS-GT ES
112 022
synchronous
Max. output [LTP] kVA/kW 11,0/8,8 6,6/5,9 11,0/8,8 6,6/5,9 11,9/10,7 13,9/11,1 9,2/8,3
Constant rating [COP] kVA/kW 10,0/8,0 6,0/5,4 10,0/8,0 6,0/5,4 10,0/9,1 11,8/9,4 6,9/6,2
Nominal voltage 400 V 3~ 230 V 1~ 400 V 3~ 230 V 1~ 230 V 1~ 400 V 3~ 230 V 1~
Nominal current 14,4 A 3~ 26,0 A 1~ 14,5 A 3~ 26,1 A 1~ 43,5 A 1~ 17 A 3~ 30 A 1~
Power factors cos (phi) 0,8 0,9 0,8 0,9 0,9 0,8 0,9
Frequency/Type of protection 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23
Engine type B & S V-Twin B & S V-Twin HONDA GX 620 HONDA GX 620
Engine version 2-cyl. 4-stroke OHV 2-cyl. 4-stroke OHV 2-cyl. 4-stroke OHV 2-cyl. 4-stroke OHV
Engine capacity 570 cm3 570 cm3 614 cm3 614 cm3
Max. output 12,0 kW/16,3 HP 12,0 kW/16,3 HP 13,5 kW/18,4 HP 13,5 kW/18,4 HP
Fuel/Tank capacity (litres) Unleaded petrol/16 Unleaded petrol/16 Unleaded petrol/24 Unleaded petrol/24
Running-time at ¾ load approx.1 2,9 l/5 h 2,9 l/5 h 3,5 l/7 h 3,5 l/7 h
Start-up system Recoil E-start incl. battery E-start incl. battery E-start incl. battery
Sound power level LWA2 97 dB(A) 97 dB(A) 96 dB(A) 96 dB(A)
Sound pressure level LPA3 72 dB(A) 72 dB(A) 71 dB(A) 71 dB(A)
Weight kg 110 115 170 175
Dimensions L x W x H in mm 945 x 570 x 640 945 x 570 x 640 960 x 638 x 664 960 x 638 x 664
Outfit 2 x 230 V/16 A 2 x 230 V/16 A 1 x 230 V/16 A 1 x 230 V/16 A
Shockproof sockets 1 x CEE 400 V/16 A 1 x CEE 400 V/16 A 1 x CEE 230 V/16 A 2 x CEE 230 V/16 A
Handles, fold-out Handles, fold-out 1 x CEE 230 V/32 A 1 x CEE 400 V/16 A
Cut-off when lack of oil, overload protection
Application areas* 400 V 230 V 400 V 230 V 230 V 400 V 230 V
Electric tools up to 7900 W 5300 W 7900 W 5300 W 9000 W 9300 W 6100 W
Construction equipment up to 5300 W 3600 W 5300 W 3600 W 6000 W 6200 W 4100 W
Inverter welding sets up to 4,5 mm 4,5 mm 5,0 mm
Compressors or pumps up to 3700 W 2500 W 3700 W 2500 W 4500 W 4700 W 3100 W
1
Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation.
2
Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m.
* As the power needs of each consumer are influenced by various factors, no claims can be derived from this table.
Professional Plus
GT Line generators
4 - 5.4 kVA
PROFESSIONAL-GT-LINE
G E N E R AT O R S
Type
Order No.
Alternator
ESE 506 HS-GT ES ISO
112 013
synchronous
ESE 506 DHS-GT ES ISO
112 006
synchronous
19
Max. output [LTP] kVA/kW 5,3/4,8 6,3/5,0 4,2/3,7
Constant rating [COP] kVA/kW 4,1/3,7 5,4/4,3 3,1/2,8
Nominal voltage 230 V 1~ 400 V 3~ 230 V 1~
Nominal current 17,8 A 1~ 7,7 A 3~ 13,5 A 1~
Power factor cos (phi) 0,9 0,8 0,9
Frequency/Type of protection 50 Hz/IP 23 50 Hz/IP 23
• Voltmeter. Weight kg 79 88
6 - 12 kVA
Made for harsh professional duty. Note on insulation monitoring:
The insulation monitoring is a major contribution to improving electrical safety and
makes the application of this unit possible in damp places such as ducts and shafts,
and in areas in which suitable grounding for the generator cannot be produced.
The isometer provides highest safety during electric fault and stops the voltage
supply instantly.
G E N E R AT O R S
20 Type
Order No.
Alternator
ESE 606 HS-GT ES ISO
112 019
synchronous
ESE 606 DHS-GT ES ISO
112 007
synchronous
ESE 1206 HS-GT ES ISO
112 016
synchronous
ESE 1206 DHS-GT ES ISO
112 017
synchronous
Max. output [LTP] kVA/kW 7,1/6,4 8,3/6,6 5,5/4,9 11,9/10,7 13,9/11,1 9,2/8,3
Constant rating [COP] kVA/kW 6,0/5,4 7,0/5,6 4,1/3,7 10,0/9,1 11,8/9,4 6,9/6,2
Nominal voltage 230 V 1~ 400 V 3~ 230 V 1~ 230 V 1~ 400 V 3~ 230 V 1~
Nominal current 26,1 A 1~ 10,1 A 3~ 17,8 A 1~ 43,5 A 1~ 17 A 3~ 30 A 1~
Power factor cos (phi) 0,9 0,8 0,9 0,9 0,8 0,9
Frequency/Type of protection 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23
Engine type HONDA GX 390 HONDA GX 390 HONDA GX 620 HONDA GX 620
Version 1-cyl. 4-stroke OHV 1-cyl. 4-stroke OHV 2-cyl. 4-stroke OHV 2-cyl. 4-stroke OHV
Engine capacity 389 cm3 389 cm3 614 cm3 614 cm3
Max. output 8,3 kW/11,3 HP 8,3 kW/11,3 HP 13,5 kW/18,4 HP 13,5 kW/18,4 HP
Fuel/Tank capacity (litres) Unleaded petrol/18 Unleaded petrol/18 Unleaded petrol/24 Unleaded petrol/24
Consumption/Running-time1 2,1 l/8,5 h 2,1 l/8,5 h 3,5 l/7 h 3,5 l/7 h
Start-up system E-start incl. battery E-start incl. battery E-start incl. battery E-start incl. battery
Sound power level LWA2 97 dB(A) 97 dB(A) 96 dB(A) 96 dB(A)
Sound pressure level LPA3 72 dB(A) 72 dB(A) 71 dB(A) 71 dB(A)
Weight kg 91 96 170 176
Dimensions L x W x H in mm 832 x 513 x 570 832 x 513 x 570 960 x 638 x 664 960 x 638 x 664
Outfit 1 x 230 V/16 A 1 x 230 V/16 A 1 x 230 V/16 A 1 x 230 V/16 A
Shockproof sockets 1 x CEE230 V/32 A 1 x CEE 400 V/16 A 1 x CEE 230 V/16 A 2 x CEE 230 V/16 A
1 x CEE 230 V/32 A 1 x CEE 400 V/16 A
Cut-off when lack of oil, overload protection, voltmeter, operating hour meter, isometer
Application areas* 230 V 400 V 230 V 230 V 400 V 230 V
Electric tools up to 5300 W 5500 W 3600 W 9000 W 9300 W 6100 W
Construction equipment up to 3600 W 3700 W 2500 W 6000 W 6200 W 4100 W
Inverter welding machines up to 3,25 mm 5,0 mm
Compressors or pumps up to 2800 W 2800 W 1900 W 4500 W 4700 W 3100 W
1
Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation.
2
Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m.
* As the power needs of each consumer are influenced by various factors, no claims can be derived from this table.
Duplex Line
generators
3 - 13 kVA
Where large and heavy units used to
work, today DUPLEX technology proves
its competence.
G E N E R AT O R S
DUPLEX-LINE
as electric machines which are difficult to start up (cement machines), and
at the same time operate electronic consumers (PE welding unit).
STOP!
One generator for
all applications!
• PE and inverter welding units. Why lower speed?
• Electrode welding units. Most generators do not run at constant load all the time but there are times of idling in
• PC and computer processing systems. between. Power is withdrawn as and when needed, such as when power tools are used.
• Lights and lighting systems. Today it is important to have power available on call.
• Complete power delivery in three
phase and alternating current with
different consumers. Points for the DUPLEXS-G5 technology
• Powerful electric tools as well as
• Slows down the engine to the lowest possible speed in idle running.
pumps and circular saws.
• Restarts at full load from the beginning.
• Miniature cranes, cement machine.
• Substantial reduction of noise level in idle running.
• Up to 25 % less fuel consumption.
• Less emission of pollutants.
21
• Life is extended several times over.
Duplex Line
generators
control panel.
NEW NEW
Type ESE 304 HG Duplex ESE 604 DHG Duplex ESE 606 DBG Duplex ESE 606 DBG ES Duplex
Order No. 113 012 113 000 113 002 113 003
22 Alternator/Duplex-G4
Max. output [LTP] kVA/kW
Constant rating [COP] kVA/kW
synchronous
3,3/2,6
3,0/2,4
synchronous
6,6/5,3
6,0/4,8
4,4/4,0
4,0/3,6
synchronous
6,6/5,3
6,0/4,8
4,4/4,0
4,0/3,6
synchronous
6,6/5,3
6,0/4,8
4,4/4,0
4,0/3,6
Nominal voltage 230 V 1~ 400 V 3~ 230 V 1~ 400 V 3~ 230 V 1~ 400 V 3~ 230 V 1~
Nominal current 13 A 1~ 8,7 A 3~ 18,0 A 1~ 8,7 A 3~ 18,0 A 1~ 8,7 A 3~ 18,0 A 1~
Power factor cos (phi) 0,9 0,8 0,9 0,8 0,9 0,8 0,9
Frequency/Type of protection 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23
Voltage regulation electronic electronic electronic electronic
Engine type HONDA GX 200 HONDA GX 390 B & S V-Twin B & S V-Twin
Version 1-cyl. 4-stroke OHV 1-cyl. 4-stroke OHV 2-cyl. 4-stroke OHV 2-cyl. 4-stroke OHV
Engine capacity 196 cm3 389 cm3 480 cm3 480 cm3
Max. output [LTP] kVA/kW 4,3 kW/5,8 HP 8,3 kW/11,3 HP 7,5 kW/10,2 HP 7,5 kW/10,2 HP
Fuel/Tank capacity (litres) Unleaded petrol/3,6 Unleaded petrol/6,5 Unleaded petrol/20 Unleaded petrol/20
Consumption/Running-time1 1,2 l/3 h 2,1 l/3 h 2,4 l/8 h 2,4 l/8 h
Start-up system Recoil Recoil Recoil E-start incl. battery
Sound power level LWA2 96 dB(A) 97 dB(A) 97 dB(A) 97 dB(A)
Sound pressure level LPA3 71 dB(A) 72 dB(A) 72 dB(A) 72 dB(A)
Weight kg 53 100 117 120
Dimensions L x W x H in mm 555 x 405 x 445 820 x 495 x 570 870 x 562 x 640 870 x 562 x 640
Outfit 2 x 230 V/16 A 3 x 230 V/16 A 3 x 230 V/16 A 3 x 230 V/16 A
Shockproof sockets 1 x CEE 400 V/16 A 1 x CEE 400 V/16 A 1 x CEE 230 V/16 A
1 x CEE 400 V/16 A 1 x CEE 400 V/16 A
Cut-off when lack of oil (except for ESE 604 DHG ES Diesel), overload protection, start-stop system (types with E-start), handles (except
Application areas* 230 V 400 V 230 V 400 V 230 V 400 V 230 V
Electronic loads up to 2400 W 4800 W 3600 W 4800 W 3600 W 4800 W 3600 W
Electric tools up to 2300 W 4700 W 3500 W 4700 W 3500 W 4700 W 3500 W
Construction equipment up to 1600 W 3200 W 2400 W 3200 W 2400 W 3200 W 2400 W
Inverter welding machines 3,25 mm 3,25 mm 3,25 mm
Compressors or pumps 1100 W 2200 W 1700 W 2200 W 1700 W 2200 W 1700 W
1
Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation.
2
Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m.
* As the power needs of each consumer are influenced by various factors, no claims can be derived from this table.
Includes
run hour meter
G E N E R AT O R S
DUPLEX-LINE
ESE 1306 DBG ES DUPLEX
ESE 1006 DBG Duplex ESE 1006 DBG ES Duplex ESE 1306 DBG ES Duplex ESE 604 DHG ES Diesel Duplex ESE 1002 DHG ES Diesel Duplex
113 004 113 005 113 006 113 009 113 010
synchronous
12,1/9,7
11,0/8,8
6,6/5,9
6,0/5,4
synchronous
12,1/9,7
11,0/8,8
6,6/5,9
6,0/5,4
synchronous
14,3/11,4
13,0/10,4
7,7/6,9
7,0/6,3
synchronous
6,5/5,3
6,0/4,8
4,4/4,0
4,0/3,6
synchronous
11,0/8,8
10,0/8,0
6,0/5,4
5,5/5,0
23
400 V 3~ 230 V 1~ 400 V 3~ 230 V 1~ 400 V 3~ 230 V 1~ 400 V 3~ 230 V 1~ 400 V 3~ 230 V 1~
15,9 A 3~ 25,0 A 1~ 15,9 A 3~ 25,0 A 1~ 18,8 A 3~ 30,4 A 1~ 8,7 A 3~ 18,0 A 1~ 14,5 A 3~ 21,7 A 1~
0,8 0,9 0,8 0,9 0,8 0,9 0,8 0,9 0,8 0,9
50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23
electronic electronic electronic electronic electronic
Includes
G E N E R AT O R S
DUPLEX-LINE
Type ESE 808 DBG ES Duplex Silent ESE 1308 DBG ES Duplex Silent ESE 1008 DHG ES Diesel Duplex Silent
Order No. 113 007 113 008 113 011
24 Alternator/Duplex G4
Max. output [LTP] kVA/kW
Constant rating [COP] kVA/kW 8,0/6,4
synchronous
8,8/7,0 5,4/5,0
5,0/4,5
synchronous
14,3/11,4
13,0/10,4
7,7/6,9
7,0/6,3
synchronous
11,0/8,8
10,0/8,0
7,7/6,9
7,0/6,3
Nominal voltage 400 V 3~ 230 V 1~ 400 V 3~ 230 V 1~ 400 V 3~ 230 V 1~
Nominal current 12,3 A 3~ 21,7 A 1~ 18,8 A 3~ 30,4 A 1~ 14,4 A 3~ 30,4 A 1~
Power factor cos (phi) 0,8 0,9 0,8 0,9 0,8 0,9
Frequency/Type of protection 50 Hz/IP 54 50 Hz/IP 54 50 Hz/IP 54
Voltage regulation electronic electronic electronic
SILENT POWER-LINE
G E N E R AT O R S
25
NEW
• Low-oil cut-off protects the engine from damage due to lack of oil. Engine capacity
Max. output
480 cm3
7,5 kW/10,2 HP
• Generous tank volume for extended run time. Fuel/Tank capacity (litres) Unleaded petrol/20
• All generators with electric starter, including battery. Consumption/Running-time1 2,4 l/8 h
• Very good access for maintenance. Start-up system E-start incl. battery
ESE 1008 DBS ES Silent ESE 1308 HS ES Silent ESE 1308 DHS ES Silent ESE 608 YS ES Diesel Silent ESE 608 DYS ES Diesel Silent
131 005
synchronous
11,0/8,8 6,6/5,9
131 007
synchronous
11,9/10,7
131 008
synchronous
13,8/11 9,1/8,2
131 009
synchronous
5,9/5,3
131 010
synchronous
6,9/5,5 4,6/4,1
27
10,0/8,0 6,0/5,4 10,0/9,0 11,8/9,4 6,9/6,2 4,9/4,4 5,7/4,6 3,3/3,0
400 V 3~ 230 V 1~ 230 V 1~ 400 V 3~ 230 V 1~ 230 V 1~ 400 V 3~ 230 V 1~
14,4 A ~ 26,0 A 1~ 43,5 A 1~ 17 A 3~ 30 A 1~ 21,3 A 1~ 8,2 A 3~ 14,3 A 1~
0,8 0,9 0,9 0,8 0,9 0,9 0,8 0,9
50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23
B & S V-Twin HONDA GX 620 HONDA GX 620 YANMAR L 100 YANMAR L 100
2-cyl. 4-stroke OHV 2-cyl. 4-stroke OHV 2-cyl. 4-stroke OHV 1-cyl. 4-stroke 1-cyl. 4-stroke
570 cm3 614 cm3 614 cm3 406 cm3 406 cm3
13,4 kW/18,0 HP 13,5 kW/18,4 HP 13,5 kW/18,4 HP 6,9 kW/9,4 HP 6,9 kW/9,4 HP
Unleaded petrol/20 Unleaded petrol/24 Unleaded petrol/24 Diesel/19 Diesel/19
2,9 l/7 h 3,4 l/7 h 3,4 l/7 h 1,4 l/13,5 h 1,4 l/13,5 h
E-start incl. battery E-start incl. battery E-start incl. battery E-start incl. battery E-start incl. battery
92 dB(A) 96 dB(A) 96 dB(A) 84 dB(A) 84 dB(A)
67 dB(A) 71 dB(A) 71 dB(A) 59 dB(A) 59 dB(A)
165 166 176 205 205
950 x 457 x 579 930 x 555 x 800 930 x 555 x 800 1050 x 620 x 830 1050 x 620 x 830
2 x 230 V/16 A 1 x 230 V/16 A 1 x 230 V/16 A 1 x 230 V/16 A 1 x 230 V /16 A
1 x CEE 230 V/16 A 1 x CEE 230 V/16 A 2 x CEE 230 V/16 A 1 x CEE 230 V/16 A 1 x CEE 230 V/16 A
1 x CEE 400 V/16 A 1 x CEE 230 V/32 A 1 x CEE 400 V/16 A 1 x CEE 230 V/32 A 1 x CEE 400 V/16 A
Operating hour meter Operating hour meter Operating hour meter
start-stop system
d protection, crane loading device
400 V 230 V 230 V 400 V 230 V 230 V 400 V 230 V
7900 W 5300 W 8900 W 9300 W 6100 W 4300 W 4500 W 2900 W
5300 W 3600 W 6000 W 6200 W 4100 W 2900 W 3000 W 2000 W
4,5 mm 5,0 mm 3,25 mm
3700 W 2500 W 4500 W 4700 W 3100 W 2200 W 2500 W 1500 W
1
Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation.
2
Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m.
* As the power needs of each consumer are influenced by various factors, no claims can be derived from this table.
Diesel Line
generators
nk
with large ta
3 - 11 kVA All machines
and insulatio
n monit oring
G E N E R AT O R S
DIESEL-LINE
28 Type
Order No.
Alternator
Max. output [LTP] kVA/kW
Constant rating [COP] kVA/kW
Nominal voltage
ESE 404 YS-GT ISO Diesel
Nominal current/cos (phi)
Power factor cos (phi)
Frequency/Type of protection
Engine type
Version
Engine capacity
Max. output
Fuel/Tank capacity (litres)
Consumption/Running-time1
Diesel Line generators have modern quality Start-up system
diesel engines with direct injection. The Sound power level LWA2
Sound pressure level LPA3
machines are of high quality, reliability and
Weight kg
long life. The engines meet the strictest Dimensions L x W x H in mm
emission standards and comply with the Outfit
Shockproof sockets
exhaust norms, e.g., CARB.
ng
Including operati
hour meter and
ls
set of site whee
G E N E R AT O R S
ESE 1004 DRS-GT ISO Diesel
DIESEL-LINE
ESE 1204 DHS ES ISO Diesel
30
G E N E R AT O R S
• 50% larger tank capacity.
• Improved tank opening, higher filler neck.
• New B & S V-Twin engines 0.5 dB(A) less noise than earlier
model´lower oil temperature - higher life expectancy.
• Noise reduced by 3 dB(A).
Option:
Control box Filling system
• Multifunction Control System E-MCS 3.0 (except ESE 304 HG, ESE 604 DYG DIN).
ESE 304 HG
32 Alternator/Duplex G4
Max. output [LTP] kVA/kW
Constant rating [COP] kVA/kW
synchronous
3,3/3,0
3,0/2,4
synchronous
6,6/5,3
6,0/4,8
4,4/4,0
4,0/3,6
synchronous
6,6/5,3
6,0/4,8
4,4/4,0
4,0/3,6
synchronous
8,8/7,0
8,0/6,4
5,5/5,0
5,0/4,5
Nominal voltage 230 V 1~ 400 V 3~ 230 V 1~ 400 V 3~ 230 V 1~ 400 V 3~ 230 V 1~
Nominal current 13 A 1~ 8,7 A 3~ 18,0 A 1~ 8,7 A 3~ 18,0 A 1~ 12,3 A 3~ 21,7 A 1~
Power factor cos (phi) 0,9 0,8 0,9 0,8 0,9 0,8 0,9
Frequency/Type of protection 50 Hz/IP 54 50 Hz/IP 54 50 Hz/IP 54 50 Hz/IP 54
Voltage regulation electronic electronic electronic electronic
Engine type HONDA GX 200 HONDA GX 390 B & S VANGUARD B & S VANGUARD
Version 1-cyl. 4-stroke OHV 1-cyl. 4-stroke OHV 2-cyl. 4-stroke OHV 2-cyl. 4-stroke OHV
Engine capacity 196 cm3 357 cm3 480 cm3 480 cm3
Max. output 4,3 kW/5,8 HP 7,5 kW/10,2 HP 7,5 kW/10,2 HP 11,9 kW/16,0 HP
Fuel/Tank capacity (litres) Unleaded petrol/3,6 Unleaded petrol/6,7 Unleaded petrol/8,5 Unleaded petrol/8,5
Consumption/Running-time1 1,2 l/3 h 2,1 l/3 h 2,4 l/3,5 h 2,4 l/3,5 h
Start-up system Recoil Recoil Recoil Recoil
Sound power level LWA2 96 dB(A) 97 dB(A) 97 dB(A) 97 dB(A)
Sound pressure level LPA2 71 dB(A) 72 dB(A) 72 dB(A) 72 dB(A)
Weight kg 53 95 117 114
Dimensions L x W x H in mm 555 x 405 x 445 700 x 440 x 580 700 x 440 x 580 700 x 440 x 580
Outfit 2 x 230 V/16 A 3 x 230 V/16 A, DIN 49442
Shockproof sockets IP 68 according to VDE-norm 1 x CEE 400/16 A, DIN 49462
Overload protective switch 3 x 2-pole, 1 x 4-pole circuit breaker, protective conductor test equipment, cut-off when lack of oil,
Cut-off when lack of oil On-board tool: 1 x spark plug spanner, 2 x spark plug, 1 x testing spike and 1 testing cable-1 m long
Multifunction control display E-MCS 3.0 standard
Types with electric start without battery ESE 604 DBG ES DIN ESE 854 DBG ES DIN
Order No. 151 012 151 014
Types with electric start and remote control incl. automatic choke without battery ESE 604 DBG ES FS DIN ESE 854 DBG ES FS DIN
Order No. 151 022 151 024
1
Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation.
2
Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m.
ACCORDING TO DIN 14685
Modern and more powerful consumers need more output
from mobile generators. The development of such units is
governed by customer and market demands.
Therefore, we constantly add new versions to our product
lines. The new DUPLEX generators in size 8 DIN frame set
new standards in precision and reliability.
Serial features:
• Multifunction Control System E-MCS 3.0.
• CanBus capability.
G E N E R AT O R S
• Carrying handles in flexible supports.
• Visual fuel level.
• Tank holds 12 liters
Optional:
8er DIN frame
ESE 804 DBG DIN ESE 1104 DBG ES DIN ESE 1304 DBG ES DIN
DUPLEX G5 technology
151 003 151 015 151 016 Slows down the engine to the lowest
synchronous
8,8/7,0
8,0/6,4
5,5/5,0
5,0/4,5
synchronous
12,1/9,7
11,0/8,8
7,7/6,9
7,0/6,3
synchronous
14,3/11,4
13,0/10,4
7,7/6,9
7,0/6,3
possible speed in idle running.
33
400 V 3~ 230 V 1~ 400 V 3~ 230 V 1~ 400 V 3~ 230 V 1~
12,3 A 3~ 21,7 A 1~ 15,9 A 3~ 30,4 A 1~ 18,8 A 3~ 30,4 A 1~
0,8 0,9 0,8 0,9 0,8 0,9
50 Hz/IP 54 DIN 40050 50 Hz/IP 54 DIN 40050 50 Hz/IP 54 DIN 40050
electronic electronic electronic
B & S VANGUARD B & S VANGUARD B & S VANGUARD Available accessories Order No.
2-cyl. 4-stroke OHV 2-cyl. 4-stroke OHV 2-cyl. 4-stroke OHV Battery 12 V - 18 Ah 163 040
maintenance-free Range with E-start
480 cm3 627 cm3 627 cm3
Refuelling system 163 110
11,9 kW/16,0 HP 14,8 kW/20,0 HP 16,7 kW/22,0 HP suitable for 3-way-fuel cock
Unleaded petrol/20 Unleaded petrol/12,0 Unleaded petrol/12,0 Exhaust pipe 163 120 except for ESE 304 HG
2,4 l/5 h 3,4 l/3,5 h 3,4 l/3,5 h cable drum ELT 50/3 E 132 513
1
Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation.
2
Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m.
* Options not retrofit.
ACCORDING TO DIN 14685 SILENT
Top-notch technology
Fire brigades, emergency management and rescue services
VA
Genuine 15 k
frame
E in 8-size DIN
TRI-
PLEX
M G
G E N E R AT O R S
TRIPLEX technology
1
Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation.
2
Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m.
Export Line
generators Not for EC
3 - 13 kVA
Not for EU countries
G E N E R AT O R S
EXPORT-LINE
Engine type YANMAR L 70 YANMAR L 100 YANMAR L 100 YANMAR L 100 RUGGERINI MD 150
Version 1-cyl. 4-stroke 1-cyl. 4-stroke 1-cyl. 4-stroke 1-cyl. 4-stroke 2-cyl. 4-stroke
Engine capacity 296 cm3 406 cm3 406 cm3 406 cm3 654 cm3
Max. output 4,8 kW/6,5 HP 6,9 kW/9,4 HP 6,9 kW/9,4 HP 6,9 kW/9,4 HP 10,0 kW/13,6 HP
Fuel/Tank capacity (litres) Diesel/3,5 Diesel/5,5 Diesel/5,5 Diesel/5,5 Diesel/24
Consumption/Running-time1 1,0 l/3,5 h 1,4 l/4 h 1,4 l/4 h 1,4 l/4 h 2,0 l/12 h
Start-up system Recoil Recoil Recoil E-start incl. battery E-start incl. battery
Weight kg 54 100 96 112 153
Dimensions L x W x H in mm 760 x 490 x 530 800 x 575 x 570 800 x 575 x 570 830 x 490 x 570 970 x 600 x 690
Outfit 2 x 230 V/16 A 1 x 230 V/16 A 1 x 230 V/16 A 2 x 230 V/16 A 1 x 230 V/16 A
Shockproof sockets 1 x CEE230 V/32 A 1 x CEE 400 V/16 A 1 x CEE 230 V/16 A 1 x CEE 230 V/32 A
1 x CEE 400 V/16 A 1 x CEE 400 V/16 A
Voltmeter Voltmeter
Overload protection
Application areas* 230 V 230 V 400 V 230 V 400 V 230 V 400 V 230 V
Electric tools up to 2900 W 4200 W 4400 W 2900 W 4400 W 2900 W 6900 W 4500 W
Construction equipment up to 2000 W 2900 W 3000 W 2000 W 3000 W 2000 W 4600 W 3000 W
Inverter welding machines up to 3,25 mm 3,25 mm 4,0 mm
Compressors or pumps 1400 W 2000 W 2200 W 1400 W 2200 W 1400 W 3500 W 2300 W
1
Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation.
2
Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m.
*As the power needs of each consumer are influenced by various factors, no claims can be derived from this table.
**Not for EU countries - export model ***Not according to directive 2000/14/EG
countries!
G E N E R AT O R S
EXPORT-LINE
ESE 1104 DBS
ESE 4000 DS
Diesel
ESE 5000 DS
Diesel
ESE 5000 DS ES
Diesel
ESE 1104 DBS ESE 1104 DBS ES ESE 1314 DBS ES Duplex 37
250 001 250 002 250 003 121 005 121 006 051 307
synchronous synchronous synchronous synchronous synchronous synchronous/Duplex-G4
3,6/3,2 5,4/4,9 5,4/4,9 11,0/8,8 6,6/5,9 11,0/8,8 6,6/5,9 14,3/11,4 7,7/6,9
3,3/3,0 4,8/4,3 4,8/4,3 10,0/8,0 6,0/5,4 10,0/8,0 6,0/5,4 13,0/10,4 7,0/6,3
230 V 1~ 230 V 1~ 230 V 1~ 400 V 3~ 230 V 1~ 400 V 3~ 230 V 1~ 400 V 3~ 230 V 1
14,3 A 1~ 20,7 A 1~ 20,7 A 1~ 14,4 A 3~ 26,1 A 1~ 14,4 A 3~ 26,1 A 1~ 14,4 A 3~ 26,1 A 1~
0,9 0,9 0,9 0,8 0,9 0,8 0,9 0,8 0,9
50 Hz/IP 23 M 50 Hz/IP 23 M 50 Hz/IP 23 M 50 Hz/IP 23 50 Hz/IP 23 50 Hz/IP 23
38
Please note!
The power requirement must not be 5 steps for quick emergency supply
higher than the continuous output of
the set. Otherwise damage can occur. 1 Generator set outdoors - set it up at a place protected from rain
Recommended: Always remain 10% and moisture.
below the continuous output. This 2 Make the connection between the generator set and the consumers.
extends the life of the machine. 3 Start the set.
4 Set the switch of the ENDRESS manual transfer switch to
Important! “emergency supply”.
The in-house installation and feeding 5 Electricity is supplied.
connection must be made by a specia-
lized electrical installation firm which Simple and quick power supply in the whole house with the ENDRESS emergency set,
warrants the proper and safe installa- a reliable supply source for all important 230 V consumers. The ENDRESS emergency
tion. That firm will also advise you as set ensures that emergency power is available throughout the house in very short time.
to the choice of the correct emergency No extension cables or multiple socket outlets.
supply set.
Inform your electricity supplier of your The feeding distributor E-NEV/1 ensures that 230 V supplied by the generator is
intention and study the supplier’s gene- distributed to emergency consumers in the house via distribution boxes.
ral terms. Conditions are different from
country to country.
EMERGENCY POWER SUPPLY
G E N E R AT O R S
39
For use in DIY rooms and similar environments, simply separate the set from
the in-house network for unrestricted mobile application.
consume
G E N E R AT O R S
40
Type manual transfer switch E-NEV/3-16 E-NEV/3-16 E-NEV/3-16 E-NEV/3-16 E-NEV/3-16 E-NEV/3-32
Order No. 162 303 162 303 162 303 162 303 162 303 162 304
Max. connection power 4800 W 4800 W 4800 W 8800 W 8800 W 10400 W
Recommended collecting power 4300 W 4300 W 4300 W 8100 W 8100 W 9400 W
Possible application areas Complete house supply
Detailed description and technical data you find on page 22-23.
EMERGENCY POWER SUPPLY
With this system, power is fed from the The decisive advantage The advantage of the Duplex technology
set into the in-house network via feeding is that the brushless synchronous genera-
distributor E-NV/3. This configuration is Synchronous 3-phase generators are not tor IP 54 has full electronic control and
the same as a standard 3-phase feeding the best choice for 3-phase emergency can stand 200% load unbalance. Besides,
system known from the supplying net- supply. Because they cannot stand this technology provides 100% constant
work. All consumers, including 3-phase, unbalanced load*. For this reason, voltage, distortion factor of less than
in the house can be supplied. Emergency ENDRESS uses the proven G4 DUPLEX 5% and 4 times the start-up current.
power sets in combination with the pro- technology for safe and reliable 3-phase This makes these sets not only suitable
ven DUPLEX technology make a perfect emergency supply. for the private home but also for small
match for emergency power supply in businesses to maintain computer supply
G E N E R AT O R S
* Unbalanced load is the state in which the phases
the whole house. of a 3-phase system carry unequal load.
in the case of a power outage. Thus,
these generators are best for the difficult
If needed, simply separate the set from requirements which consumers make on
the in-house network for unrestricted an emergency generating set.
mobile application.
41
ESE 1308 ES Duplex Silent ESE 1008 DBG ES Diesel Duplex Silent
42
ENDRESS fully automatic emergency generator systems, or several phases, the engine starts automatically - manual
together with the automatic control unit, automatically restore starting is also possible. When the power supply is restored,
the power supply if the mains supply fails. The mains voltage the set cuts out automatically.
is monitored automatically and if a drop is detected in one
Possible application areas Heating system Heating system Heating system Heating system Heating system
Lighting Lighting Lighting Lighting Lighting
Multimedia Multimedia Multimedia Multimedia Multimedia
Communication Communication Communication Communication Communication
Appliances Appliances Appliances Appliances Appliances
Cooling Cooling Cooling
Pumps Pumps
Warm water- Warm water-
preparation preparation
Detailed description and specifications you find on page 17-18. page 27 page 29 page 29
EMERGENCY POWER SUPPLY
ENDRESS automatic emergency set 5 - 13 kVA.
This series is a complete system with latest generator techno- generator IP 54 with electronic control), which are excellent
logy. The high-performance synchronous generators supply for individual household consumers, also for medium-size
single-phase 230 V consumers in the house. For 3-phase supply, businesses, e.g., to maintain the power supply to computers
ENDRESS uses DUPLEX generators (a brushless synchronous in case of a mains power outage.
G E N E R AT O R S
These generators are factory wired with the automatic
emergency machine and therefore need no socket outlet.
Automatic emergency function cannot be service fitted.
43
Only strong components will make powerful generators.
44
Welding generator selection chart
The table below can be used for guidance and does
not purport to be exhaustive. No claims can be based
on this table.
welding
current (A) Electrode
ENDRESS welding generators are On-load factor (OLF) 30 ø 1,5
OLF = tb x 100% 50 ø2
versatile energy sources which supply (tb + tp) 70 ø 2,5
three-phase, alternating and welding tb = load duration
90 ø 3,25
tp = pause duration
currents. Due to their excellent welding tb + tp = cycle duration 110 ø 3,25
characteristics, they are simply indi- (acc. To VDE 0544. tb + tp = 10 min) 130 ø 3,25
150 ø4
spensable for repair work such as in Example: 170 ø4
steel and pipeline engineering. 60% on-load factor yields a succession
190 ø5
of 6 min welding and 4 min pause.
210 ø5
• Continuous welding current regulation - at constant motor speed.
• Silent, easy ignitable arcs, drop weld proof, K symbol (only at DC-models).
• Modern HONDA-OHV engine technology.
• Economical, reliable diesel units.
• Sturdy asynchronous generators.
• AC = AC welding for simple welding.
• DC = DC welding for professional welding.
ESE 404 SHS-AC ESE 804 SDYA-DC ES
WELDING-LINE
G E N E R AT O R S
ESE 704 SHS-AC
front view
Available accessories
Adapter CEE 230 V/16 A to
shockproof socket 230 V/16 A 162 004 162 004 162 004 162 004 162 004
Set of wheels with handles 161 000 161 000 161 000 161 000 161 001
Welding accessories 162 000 162 000 162 000 162 000 162 000
Application areas
Rutile electrode max. Ø mm 4 4 4 5 4
Basic electrode max. Ø mm – – 3,25 4 4
Cellulose electrode max. Ø mm – – 3,25 5 4
1
Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation.
2
Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m.
PTO generators
12 - 55 kVA
PTO GENERATORS
G E N E R AT O R S
46
PTO GENERATORS
An ENDRESS power take-off generator substantially improves the versatility and
utilization of e.g. municipal tractors, provides a secure supply and widens the
application capabilities of many electrical appliances and machines.
G E N E R AT O R S
Top rate equipment and quality
47
• • • •
• • • •
• • • •
• • • • Available accessories Order No.
• • • •
Earth rod 342 304
Voltage monitoring module 512 000
• • • • Adapter CEE 230 V/16 A to
40
30
48
20
Max. delivery head in meters
max. För derhöhe in Mete r
10
Tough, robust motor pumps for the harsh Using world-wide proven HONDA OHV engines with long service life,
use in construction, industry, communities, easy start-up and high reliability. Top quality materials for all pump
agriculture and rigging. components afford full functionality, good performance and little need
for maintenance at all times. Due to their robust design, self-priming
sewage pumps from ENDRESS allow for a professional transport of
clean and heavily soiled water in construction, industry, agriculture and
communities. An ENDRESS motor pump ensures independence from
electricity and water mains and gives the necessary security every time.
ENGINE PUMPS
EMP 205 EMP 305 EMP 305 T
The versatile ENDRESS centrifugal pumps Depending on the model, centrifugal Engine pumps with decisive advantages
G E N E R AT O R S
are in their element when a high flow rate pumps allow a maximum of 27mm solids • OHV engine technology from HONDA.
and high output are required. The following through. Both the gyroscope and impeller • Very high delivery rates.
examples are typical applications for which are well resistant to abrasion and in addi- • Extremely high insensitivity to impurity
they can be used: Draining of ditches, tion sealing elements which run in an oil laden water.
cable shafts, basements, foundation pits bath give the necessary reliability under • Tough and long life due to a resistance
or sewage works, irrigation of fields as the most severe of operating conditions. to abrasive materials.
well as the emptying and filling of ponds, Cleaning is facilitated to a large extent
the drainage of quarries, pits and coal by two swing-out closure blocks.
mines.
Engine type HONDA GX 120 HONDA GX 160 HONDA GX 160 HONDA GX 240
Version 1-cyl. 4-stroke OHV 1-cyl. 4-stroke OHV 1-cyl. 4-stroke OHV 1-cyl. 4-stroke OHV
Engine capacity 118 cm3 163 cm3 163 cm3 242 cm3
Max. output 2,9 kW/3,9 HP 4,1 kW/5,6 HP 4,1 kW/5,6 HP 5,9 kW/8,0 HP
Rotation speed rpm 3600 3600 3600 3600
Fuel/Tank capacity (litres) Unleaded petrol/2,5 Unleaded petrol/3,6 Unleaded petrol/3,6 Unleaded petrol/6
Consumption/Running-time1 1,25 l/2 h 1,8 l/2 h 1,7 l/2 h 2,6 l/2,3 h
Start-up system Recoil Recoil Recoil Recoil
Sound power level LWA2 103 dB(A) 105 dB(A) 106 dB(A) 110 dB(A)
Sound pressure level LPA3 78 dB(A) 80 dB(A) 81 dB(A) 95 dB(A)
Weight kg 20 29 47 58
Dimensions L x W x H in mm 468 x 352 x 385 505 x 374 x 453 620 x 462 x 481 690 x 485 x 537
Outfit Cut-off when lack of oil, 3 x hose clip, 2 x hose couplings, 1 x stainer, spark plug spanner
Possible application areas Rotary pumps for irrigation and drainage, extraction Dirty-water pump Sturdy dirty-water pump
of clear or only moderately polluted media for irrigation and drainage for industrial, municipal and
in construction agricultural application
industry and agriculture
Available accessories
Suction tube 2’’ 8 m 38 410 38 410
Suction tube 2’’ 8 m 38 407 38 407
Pressure tube 2’’ 15 m 38 411 38 411
Pressure tube 2’’ 15 m 38 408 38 408
Pressure tube-extension 2’’ 10 m 38 414 38 414
Pressure tube-extension 3’’ 10 m 38 409 38 409
Reduction coupling 3’’ to 2’’ 38 483 38 483
Suction tube, Pressure tube and pressure tube extension are equipped with quick couplings.
1
Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation.
Building site
generators
13 - 40 kVA
BUILDING SITE GENERATORS
G E N E R AT O R S
50
ESE 40 DL-B
for the rough service on construction sites in. They are equipped
• Low noise emission.
conditions.
• Service friendly due to modular construction.
BUILDING SITE GENERATORS
G E N E R AT O R S
ESE 20 DW-B
Options
not retrofit Order No.
Emergency power supply 342 400 342 400 342 400 342 400
incl. preheating system, 1 x CEE 400 V socket
Electronic engine speed governor 342 001 342 001
Available accessories:
Load transfer switch panel 343 012/E-US 20 343 000/E-US 32 343 001/E-US 45 343 002/E-US 60
Earth rod 343 304 343 304 343 304 342 304
1
Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation.
2
Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m.
Floodlight
systems
!
Ideal for leasing
FLOODLIGHT SYSTEMS
and mobile
Floodlight system
e unit!
generator in on
Transport securing
MOBILE
52
Base turns 360 degrees steplessly
EFA 950 S6 MK
FLOODLIGHT SYSTEMS
• Maintenance-free aluminum • Internal helical cable for more operational safety.
telescoping pole. • Light directly availably at site.
• Integrated drop arrest device. • Light pole turns 360 degrees steplessly.
• Simple handling by crank. • Maintenance-free anodized aluminium pole.
• Light pole turns 360 degrees • swivel-type special halogen flood lamps.
steplessly. • Fully galvanized chassis acc. to highway code.
• Self-locking crank winch. • Adjustable drawbar height.
• Swivel-type special halogen flood • Extending stabilizers for high stability.
lamps.
• Fully galvanized chassis acc.
to highway code. EFA 850 S6 P
MOBILE
(except ESE 650 S4).
EFA 650 S4
53
NEW NEW
Type EFA 650 S4 EFA 830 S4 EFA 830 S6 EFA 850 S6 V EFA 850 S6 P EFA 950 S6 MK
Order No. 716 200 716 260 716 280 716 240 716 290 716 230
Light output 4 x 1500 W 4 x 1500 W 6 x 1500 W 6 x 1500 W 6 x 1500 W 6 x 1500 W
3 x switchable 3 x switchable 3 x switchable 3 x switchable 3 x switchable 3 x switchable
Max. spotlight height 6,5 m 8,3 m 8,3 m 8,5 m 8,5 m 9,5 m
Min. transport height 2,68 m 2,55 m 2,55 m 2,55 m 2,75 m 2,.25 m
Lamp poles
Pole continuously 360° rotatable continuously 360° rotatable continuously 360° rotatable continuously 360° rotatable continuously 360° rotatable continuously 360° rotatable
Version Alu-teleskopic pole Alu-teleskopic pole Alu-teleskopic pole Alu-teleskopic pole Alu-teleskopic pole Steel mast/folding
Function mech./hand crank mech./hand crank mech./hand crank pneumatic pneumatic mech./hand crank
Undercarriage according
to StVZO FG 75 LM FG 100 LM FG 160 LM FG 2500 LM Tandem FG 160 LM FG 160 LM
Width in mm 1600 1540 1650 1720 1650 1650
Length over all in mm 3400 4230 5150 5450 5150 5150
Tyres 13’’ 13’’ 14’’ 15’’ 14’’ 14’’
Drawbar rigid height adjustable height adjustable height adjustable height adjustable height adjustable
Overrun brake non-braked yes yes yes yes yes
Total weight allowed kg 750 1000 1600 2500 1600 1600
Supp. weight allowed kg 50 75 75 100 75 75
Recommended ESE 1008 DBS ES Silent ESE 15 DW-B ESE 20 DW-B ESE 30 DL/MS ESE 30 DW-B ESE 20 DW-B
generators ESE 1308 DBS ES Silent ESE 30 DL-B ESE 40 DL/MS ESE 40 DW-B ESE 30 DL-B
ESE 1204 DHS ES ISO Diesel ESE 40 DL-B ESE 65 DW/MS ESE 40 DL-B
ESE 15 DW/MS ESE 80 DW/MS ESE 15 DW/MS
ESE 20 DW/MS ESE 20 DW/MS
Power supply systems
15 - 600 kVA
P OW E R S U P P LY SYS T E M S
SUPPLY SYSTEMS
55
Easy to access, large air filter
with exchangeable filter
elements.
as standard:
Large diesel filter with water Battery main switch Manual oil drain pump
separator and drain plug. separates the battery for simple and quick
from all components oil change.
of the generator.
Manual, analogical
control panel
P OW E R S U P P LY SYS T E M S
P OW E R S U P P LY SYS T E M S
ENDRESS emergency generator systems,
together with the automatic control unit,
automatically restore the power supply if
the mains supply fails. The mains voltage
is monitored automatically and if a drop is
detected in one or several phases, the
SUPPLY SYSTEMS
engine starts automatically - manual star-
ting is also possible.
LEDs
• Mains availability
• Mains contactor ON
Programming switch • Generator contactor ON
• Differential protection tripped
Mode selection
• Generator service
1 Automatic Test T
• Engine alarm status
2 Automatic standard mode A
• Battery charger ON
3 Locked mode
• Battery ON
Electronic system disabled, required for maintenance
The ESE 15 and ESE 20 model series engines and turbocharger (depending on STAMFORD ensure the parallel operation of
have compact water-cooled DEUTZ model). These oil-cooled diesel engines ohmic and inductive consumers.
industrial engines of the D2009 series. are very reliable and long-lived. Low fuel
and oil consumption make them very Designed for maximum output under the
Little maintenance and high quality are economical in continuous service. toughest of conditions and made accor-
typical of these engines which are in world- ding to VDE 0530, insulation class H.
SUPPLY SYSTEMS
wide use. The ESE 30 and ESE 40 series The brushless synchronous generators with
are equipped with oil-cooled DEUTZ electronic regulation from Mecc Alte and
58
ESE 80 DW
General specifications
Type ESE 15 ESE 20 ESE 30 ESE 40
Max. output [LTP] kVA/kW 15,0/12,0 21,1/16,8 30,0/24,0 41,2/33,0
Constant rating [COP] kVA/kW 14,3/11,4 20,1/16,1 29,0/32,2 39,3/31,4
Alternator type Mecc Alte ECO 32 L/4 STAMFORD BCI 184 E STAMFORD BCI 184 F STAMFORD BCI 184 J
Version/Insulation synchronous/class H synchronous/class H synchronous/class H synchronous/class H
Nominal voltage 400 V 3~/230 V 1~ 400 V 3~/230 V 1~ 400 V 3~/230 V 1~ 400 V 3~/230 V 1~
Nominal current 20,6 A 3~/0,8 29,0 A 3~/0,8 41,9 A 3~/0,8 56,7 A 3~/0,8
Frequency 50 Hz 50 Hz 50 Hz 50 Hz
Regulation electronic (± 1,5) electronic (± 1,5) electronic (± 1,5) electronic (± 1,5)
Engine type DEUTZ D2009 L03 DEUTZ D2009 L04 DEUTZ F4M 2011 DEUTZ BF4M 2011
Version 3-cyl. 4-stroke Diesel 4-cyl. 4-stroke Diesel 4-cyl. 4-stroke Diesel 4-cyl. 4-stroke Diesel
Intake mode/Cooling system Suction engine/water-cooled Suction engine/water-cooled Suction engine/oil-cooled Turbor/oil-cooled
Engine capacity 1718 cm3 2290 cm3 3110 cm3 3110 cm3
Constant rating [PRP] kW 14,8 19,1 27,6 36,4
Rpm/Regulation 1500/mechanical 1500/mechanical 1500/mechanical 1500/mechanical
Cooling air volume m3/h N/A N/A 1800 2370
Start-up system/Battery V/Ah E-Start 2 kW/12/45 E-Start 2 kW/12/70 E-Start 3 kW/12/70 E-Start 3 kW/12/70
Type
Type series DW/DL Model: Opfen version incl. automatic control panel, preheating system and terminal box
ESE 15 DW* ESE 20 DW* ESE 30 DL ESE 40 DL
59
Order No. 330 200 330 201 330 202 330 203
Fuel/Tank capacity (litres) Diesel/51 Diesel/51 Diesel/90 Diesel/90
Consumption/Running-time1 2,6 l/19,5 h 3,6 l/14 h 5,3 l/17 h 6,9 l/13 h
Weight kg 410 445 714 761
Dimensions L x W x H in mm 1600 x 870 x 1000 1600 x 870 x 1000 1800 x 750 x 1570 1800 x 750 x 1570
Outfit Automatic control panel with control unit and integrated battery charger, main switch ON/OFF, main fuse, emergency stop switch, residual current device,
engine preheating system, connection device for power supply and load transfer switch directly at main switch, all-pole protection up to type 65 DW,
from type 80 DW fuse protection by power switch, battery pre-charged dryly.
* ESE 15 DW max. output [LTP] kVA/kW 13,8/11,0 · constant rating [PRP] kVA/kW 13,0/10,4 · alternator type: LINZ E1S 13 M 4-13 kVA · regulation: compound
* ESE 15 DW max. output [LTP] kVA/kW 20,1/16,1 · constant rating [PRP] kVA/kW 19,0/15,2 · alternator type: LINZ E1S 13 M 4-19 kVA · regulation: compound
Type series AS Model: Closed version with automatic control panel, preheating system, terminal box and leak proof tray
Type ESE 15 DW/AS ESE 20 DW/AS ESE 30 DL/AS ESE 40 DL/AS
Order No. 331 200 331 201 331 202 331 203
Fuel/Tank capacity (litres) Diesel/55 Diesel/55 Diesel/120 Diesel/120
Consumption/Running-time1 2,8 l/28,5 h 3,9 l/20,5 h 5,6 l/21,5 h 7,5 l/16 h
Sound power level LWA2 91 dB(A) 91 dB(A) 92 dB(A) 92 dB(A)
Sound pressure level LWA3 66 dB(A) 66 dB(A) 67 dB(A) 67 dB(A)
Weight kg 720 785 992 1064
Dimensions L x W x H in mm 1800 x 830 x 1295 1800 x 830 x 1295 2225 x 1100 x 1290 2225 x 1100 x 1290
Outfit Automatic control panel with control unit and integrated battery charger, main switch ON/OFF, main fuse, emergency stop switch, residual current device,
engine preheating system, connection device for power supply and load transfer switch directly at main switch, all-pole protection up to type 65 DW,
from type 80 DW fuse protection by power switch, leak proof tray, oil suction pump (manual), crane loading devive, soundproof canopy, battery pre-charged
dryly.
Type series MS Model: Closed version with key start, analogue control panel, terminal box, soundproof canopy and leak proof tray
Type ESE 15 DW/MS ESE 20 DW/MS ESE 30 DL/MS ESE 40 DL/MS
Order No. 332 200 332 201 332 202 332 203
Outfit Manual control panel with control unit, main switch ON/OFF, main fuse, emergency stop switch, residual current device, engine preheating system,
connection device for power supply and load transfer switch directly at main switch, all-pole protection up to type 65 DW, from type 80 DW fuse protection
by power switch, terminal strip for full collection of power, leak proof tray, oil suction pump (manual), crane loading device, soundproof canopy, battery
pre-charged dryly.
Load transfer switch
Order No. 343 012/E-US 20 343 000/E-US 32 343 001/E-US 45 343 002/E-US 60
1
Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation.
2
Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m.
DEUTZ
water-cooled engines
60 - 540 kVA
P OW E R S U P P LY SYS T E M S
sive high-pressure injection system and the toughest of conditions and made accor-
individual injection pumps reduce the fuel ding to VDE 0530, insulation class H.
consumption of the engines.
Engine type DEUTZ BF4M 2012-G2 DEUTZ BF4M 2012 C DEUTZ BF4M 1013 EC
60 Version
Intake mode/Cooling system
Engine capacity
4-cyl. 4-stroke Diesel
Turbo/water-cooled
4040 cm3
4-cyl. 4-stroke Diesel
Tb-Intercool/water-cooled
4040 cm3
4-cyl. 4-stroke Diesel
Tb-Intercool/water-cooled
4760 cm3
Constant rating [PRP] kW 52,0 66,1 91,1
Rpm/Regulation 1500/mechanical 1500/mechanical 1500/mechanical
Cooling air volume 5400 4680 6120
Start-up system/Batterie V/Ah E-Start 3 kW/12/95 E-Start 3 kW/12/95 E-Start 3,1 kW/12/145
Serial equipment at a glance:
Type series DW Model: Open version incl. automatic control panel, preheating system a
Leak proof tray Type ESE 65 DW ESE 80 DW ESE 110 DW
in AS/MS series models to ensure that Order No. 330 204 330 205 330 206
Fuel/Tank capacity (litres) Diesel/240 Diesel/240 Diesel/240
no operating fluid is spilled. Consumption/Running-time1 10,2 l/23,5 h 11,7 l/20,5 h 16,5 l/14,5 h
Weight kg 865 945 1326
Dimensions L x W x H in mm 2200 x 1000 x 1620 2200 x 1000 x 1620 2200 x 1000 x 1620
Engine pre-heating system Outfit Automatic control panel with control unit and integrated battery charger, main switch ON/OFF, main
in models with automatic emergency battery pre-charged dryly.
supply. Type series AS Model: Closed version with automatic control panel, preheating system,
Type series MS Model: Closed version with key start, analogue control panel, terminal b
Type ESE 65 DW/MS ESE 80 DW/MS ESE 110 DL/MS
Order No. 332 204 332 205 332 206
Outfit Manual control panel with control unit, main switch ON/OFF, main fuse, emergeny stop switch, resid
leak proof tray, oil suction pump (manual), crane loading device, soundproof canopy, battery pre-ch
Load transfer switch
Order No. 343 003/E-US 90 343 004/E-US 110 343 005/E-US 200
1
Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation.
2
Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m.
P OW E R S U P P LY SYS T E M S
SUPPLY SYSTEMS
AS version
Optional: Socket outlet combination
ESE 145 ESE 170 ESE 195 ESE 220 ESE 530 ESE 560
142/113 167/134 194/155 220/176 528/422 546/437
135/108 159/127 186/149 208/166 459/367 509/407
STAMFORD UCI 274 E STAMFORD UCI 274 E STAMFORD UCI 274 G STAMFORD UCI 274 H Mecc Alte ECO 40 3S Mecc Alte ECO 40 3S
synchronous/class H synchronous/class H synchronous/class H synchronous/class H synchronous/class H synchronous/class H
400 V 3~/230 V 1~ 400 V 3~/230 V 1~ 400 V 3~/230 V 1~ 400 V 3~/230 V 1~ 400 V 3~/230 V 1~ 400 V 3~/230 V 1~
195 A 3~/0,8 230 A 3~/0,8 269 A 3~/0,8 300 A 3~/0,8 663 A 3~/0,8 735 A 3~/0,8
50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz
electronic (± 1,5) electronic (± 1,5) electronic (± 1,5) electronic (± 1,5) electronic (± 1,5) electronic (± 1,5)
DEUTZ BF6M 1013 E DEUTZ BF6M 1013 EC DEUTZ BF6M 1013 FC G2 DEUTZ BF6M 1013 FC G3 DEUTZ BF8M 1015 C G2 DEUTZ BF8M 1015 CP
6-cyl. 4-stroke Diesel
Turbo/water-cooled
7150 cm3
4-cyl. 4-stroke Diesel
Tb-Intercool/water-cooled
7150 cm3
4-cyl. 4-stroke Diesel
Tb-Intercool/water-cooled
7150 cm3
4-cyl. 4-stroke Diesel
Tb-Intercool/water-cooled
7150 cm3
V 8-cyl. 4-stroke Diesel
Tb-Intercool/water-cooled
15900 cm3
V 8-cyl. 4-stroke Diesel
Tb-Intercool/water-cooled
15900 cm3
61
117,8 138,1 161,6 178,6 391,3 433,9
1500/mechanical 1500/mechanical 1500/electronic 1500/electronic 1500/electronic 1500/electronic
9000 10800 7377 8852 24120 33120
E-Start 3,1 kW/12/145 E-Start 3,1 kW/12/145 E-Start 3,1 kW/24/2 x 145 E-Start 3,1 kW/24/2 x 145 E-Start 5,4 kW/24/2 x 200 E-Start 5,4 kW/24/2 x 200
343 005/E-US 200 343 006/E-US 325 343 006/E-US 325 343 006/E-US 325 343 0109/E-US 1000 343 010/E-US 1000
VOLVO-PENTA
water-cooled engines
310 - 600 kVA
P OW E R S U P P LY SYS T E M S
VOLVO-PENTA water-cooled 4-stroke The electronic engine control ensures put under the toughest of conditions and
6-cyliner in-line engines the powerful optimal steady-state behavior under made according to VDE 0530, insulation
diesel engines with turbocharger/charge conditions of peak load (max. 0.3 s). class H.
air cooler provide professional drive.
The industrial engines with direct injec- Mecc Alte generator, the brushless high-
tion and optimized combustion respond performance synchronous generator
quickly in cold weather and have low with electronic control, ensures the
SUPPLY SYSTEMS
exhaust emission and high economy of parallel operation of ohmic and inductive
operation. consumers. Designed for maximum out-
62
General specifications
Type ESE 275 ESE 330 ESE 415
Max. output [LTP] kVA/kW 275/220 330/264 414/331
Constant rating [PRP] kVA/kW 252/202 315/264 378/302
Alternator type Mecc Alte ECO 38 1L Mecc Alte ECO 38 2L Mecc Alte ECO 40 31
Building class/Insulation synchronous/class H synchronous/class H synchronous/class H
Nominal voltage 400 V 3~/230 V 1~ 400 V 3~/230 V 1~ 400 V 3~/230 V 1~
Nominal current/cos (phi) 363 A 3~/0,8 454 A 3~/0,8 546 A 3~/0,8
Frequency 50 Hz 50 Hz 50 Hz
Regulation
Engine type
Version
electronic (± 1,5)
Type series VW Model: Open version incl. automatic control panel, preheating system and terminal box
Type ESE 275 VW ESE 330 VW ESE 415 VW
Order No. 330 224 330 215 330 216
Fuel/Tank capacity (litres) Diesel/636 Diesel/636 Diesel/636
Consumption/Running-time1 39 l/16 h 48,9 l/13 h 57,8 l/11 h
Weight kg 2108 2600 3050
Dimensions L x W x H in mm 2950 x 1300 x 1800 3300 x 1400 x 1887 3300 x 1400 x 1917
Outfit Automatic control panel with control unit and integrated battery charger, main switch ON/OFF, main fuse, emergency stop
switch, residual current device, engine preheating system, connection device for current collection and load transfer
switch directly at main switch, all-pole protection up to type 65 DW, from type 80 DW fuse protection by power switch,
battery pre-charged drylyn
Type series AS Model: Closed version with automatic control panel, preheating system, terminal box and leak proof tray
Type ESE 275 VW/AS ESE 330 VW/AS ESE 415 VW/AS
Order No. 331 224 331 215 331 216
Fuel/Tank capacity (litres) Diesel/636 Diesel/636 Diesel/636
Consumption/Running-time1 39 l/16 h 48,9 l/13 h 74,8 l/8,5 h
Sound power level LWA2 97 dB(A) 97 dB(A) 97 dB(A)
Sound pressure level LPA3 72 dB(A) 72 dB(A) 72 dB(A)
Weight kg 2726 3200 3675
Dimensions L x W x H in mm 3550 x 1360 x 2016 3950 x 1460 x 2095 3950 x 1460 x 2095
Outfit Automatic control panel with control unit and integrated battery charger, main switch ON/OFF, main fuse, emergeny stop
switch, residual current device, engine preheating system, connection device for current collection and load transfer
switch directly at main switch, all-pole protection up to type 65 DW, from type 80 DW fuse protection by power switch,
leak proof tray, oil suction pump (manual), crane loading device, soundproof canopy, battery pre-charged dryly
Load transfer switch
Order No. 343 007/E-US 400 343 008/E-US 500 343 009/E-US 700
1
Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation.
2
Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m.
VOLVO-PENTA
water-cooled engines
440 - 600 kVA
P OW E R S U P P LY SYS T E M S
SUPPLY SYSTEMS
AS version
Optional: Socket outlet combination
General specifications
Type ESE 450 ESE 510 ESE 560 ESE 590
Max. output [LTP] kVA/kW 437/350 507/406 546/437 601/481
Constant rating [PRP] kVA/kW 411/329 461/369 505/404 571/457
Alternator type Mecc Alte ECO 40 1S Mecc Alte ECO 40 3S Mecc Alte ECO 40 3S Mecc Alte ECO 40 1L
Building class-/Insulation synchronous/class H synchronous/class H synchronous/class H synchronous/class H
Nominal voltage 400 V 3~/230 V 1~ 400 V 3~/230 V 1~ 400 V 3~/230 V 1~ 400 V 3~/230 V 1~
Nominal current/cos (phi) 593 A 3~/0,8 665 A 3~/0,8 729 A 3~/0,8 824 A 3~/0,8
64 Frequency
Regulation
Engine type
50 Hz
electronic (± 1,5)
Type series VW Model: Open version incl. automatic control panel, preheating system and terminal box
Type ESE 450 VW ESE 510 VW ESE 560 VW ESE 590 VW
Order No. 330 217 330 218 330 219 330 220
Fuel/Tank capacity (litres) Diesel/636 Diesel/636 Diesel/636 Diesel/636
Consumption/Running-time1 63,6 l/10 h 66,9 l/9,5 h 74,8 l/8,5 h 84,8 l/7,5 h
Weight kg 3050 3620 3620 3850
Dimensions L x W x H in mm 3300 x 1400 x 1197 3500 x 1500 x 2120 3500 x 1500 x 2120 3500 x 1500 x 2120
Outfit Automatic control panel with control unit and integrated battery charger, main switch ON/OFF, main fuse, emergeny stop switch, residual current device,
engine preheating system, connection device for current collection and load transfer switch directly at main switch, all-pole protection up to type 65 DW,
from type 80 DW fuse protection by power switch, battery pre-charged dryly
Type series AS Model: Closed version with automatic control panel, preheating system, terminal box and leak proof tray
Type ESE 450 VW/AS ESE 510 VW/AS ESE 560 VW/AS ESE 590 VW/AS
Order No. 331 217 331 218 331 219 331 220
Fuel/Tank capacity (litres) Diesel/636 Diesel/636 Diesel/636 Diesel/636
Consumption/Running-time1 63,6 l/10 h 66,9 l/9,5 h 74,8 l/8,5 h 84,8 l/7,5 h
Sound power level LWA2 97 dB(A) 98 dB(A) 105 dB(A) 105 dB(A)
Sound pressure level LPA3 72 dB(A) 73 dB(A) 80 dB(A) 80 dB(A)
Weight kg 3675 4500 4500 4890
Dimensions L x W x H in mm 3950 x 1460 x 2095 4400 x 1560 x 2250 4400 x 1560 x 2250 4400 x 1560 x 2250
Outfit Automatic control panel with control unit and integrated battery charger, main switch ON / OFF, main fuse, emergeny stop switch, residual current device,
engine preheating system, connection device for current collection and load transfer switch directly at main switch, all-pole protection up to type 65 DW, from
type 80 DW fuse protection by power switch, leak proof tray, oil suction pump (manual), crane loading device, soundproof canopy, battery pre-charged dryly
Load transfer switch
Order No. 343 009/E-US 700 343 010/E-US 700 343 010/E-US 1000 343 010/E-US 1000
1
Consumption/litres in hours, running-time in hours. These indications are based on approx. values at ¾ load and therefore without obligation.
2
Sound level indication according to the directive for noise emission law 2000/14/EG. 3 Sound pressure level at distance of 7 m.
Power supply
systems - an aid
to choice
P OW E R S U P P LY SYS T E M S
Application survey*
Emergency generating sets
*with consideration of the charge state of the diesel engine
AN AID TO CHOICE
Power output in kw Type The opposite table provides a quick survey of what
ESE 30
ESE 40
ESE 65
ESE 80
ESE 110
ESE 145
ESE 170
ESE 195
at 400 V 3~/50 Hz generator is the right choice for your consumers
and your needs. The information is only for guidan-
ce and is not exhaustive. The power requirement
Machines < 10 of consumers depends on several factors and the-
with no-load < 14 refore no claims can be based on the table.
fans < 19
rotary pumps < 28 Abbreviations used in the tables:
circular saws < 30 COP = Continuous power of the unit
< 38 Continuous power in full power application
< 42 without a time limit.
< 50 PRP = Variable continuous power of the unit
< 67 Continuous power in a varying load operation
Machines < 4,5 (average 80% load within 24 hrs.) without time
with load < 6,5 limit.
fans with high < 9
LTP = Limited time unit power
flywheel moment < 13
A maximum power which can be applied for a
compressors < 14
conveyors <
<
17
19
maximum of 500 hours per year, whereby in
a variable load operation 300 hours should not
65
construction be exceeded.
< 22
machinery
< 32
Machines with < 3
heavy starting < 4,5
Explanation of the ENDRESS
elevators < 6
type code
heavy < 9
conveyors < 10
< 12 ESE 110 D W / AS
construction
< 13 S = Noise cover
machinery
< 15
< 21 A = Automatic
All above < 9 M = Manual
mentioned < 14
W = Water-cooled
machines < 18 A = Air-cooled
but with < 27 L = Oil-cooled
star-delta- < 29
< 36 D = DEUTZ
connection V = VOLVO PENTA
< 39
< 47 110 = Series
< 64
ESE = ENDRESS
The above table serve as a guideline for the 1st load connection. Smaller consumers GENERATOR
using a serial or ohmic load connection may utilize the generator up to it’s nominal
power.
Accessory items
- description -
P OW E R S U P P LY SYS T E M S
230 V/16 A
control panel. They consist of a steel cabinet which is delivered separately from the
1 x CEE 230 V/16 A, 1 x CEE 400 V/16 A
generator.
1 x CEE 400 V/32 A, 1 x CEE 400 V/63 A
This cabinet is equipped as follows: 2 mechanical and electrically locked contactor
ZUBEHÖR
pairs for load transfer between mains and generator as well as all necessary auxiliary
controls.
To ensure easy connection
to the automatic control
panel at the generator,
everything is factory-wired
Battery main on a terminal block which
switch separates is integrated in the cabinet.
the battery from all The type of protection of the
components steel cabinet is IP 45.
of the generator.
Includes emergency stop
button and 5 m
Earth rod
If a generator is used in an RCD environ-
ment, the generator must be grounded
with a earth rod.
Galvanized
heavy duty
base frame
3-way fuel cock
for direct connection of an external fuel
tank.
Available
accessories
Article
P OW E R S U P P LY SYS T E M S
Profi Power PMG Electro-plated Residential silencer for Residual current device
compensator
combination
description Paket con- base frame fix installation All-current sensitive
Automatic
fuel pump
Elektronic
Earth rod
(Rental-Kit) troller
govenor
Sockets
Exhaust
speed
Order No. 342 200 342 310 342 311 342 305 342 006 342 001 342 021 342 110 342 111 342 112 342 015 342 016 342 017 342 018 342 019 342 012 342 013 342 014 342 303
Modell
ESE 15 DW
ESE 15 DW/AS
ESE 15 DW/MS
ESE 20 DW
ESE 20 DW/AS
ACCESSORIES
ESE 20 DW/MS
ESE 30 DL
ESE 30 DL/AS
ESE 30 DL/MS
ESE 40 DL
ESE 40 DL/AS
ESE 40 DL/MS
ESE 65 DW
ESE 65 DW/AS
ESE 65 DW/MS
ESE 80 DW
ESE 80 DW/AS
ESE 80 DW/MS
ESE 110 DW
ESE 110 DW/AS
ESE 110 DW/MS
ESE 145 DW
ESE 145 DW/AS
ESE 145 DW/MS
ESE 170 DW
ESE 170 DW/AS
67
ESE 170 DW/MS
ESE 195 DW
ESE 195 DW/AS
ESE 195 DW/MS
ESE 220 DW
ESE 220 DW/AS
ESE 220 DW/MS
ESE 530 DW
ESE 530 DW/AS
ESE 560 DW
ESE 560 DW/AS
ESE 310 VW
ESE 310 VW/AS
ESE 330 VW
ESE 330 VW/AS
ESE 415 VW
ESE 415 VW/AS
ESE 450 VW
ESE 450 VW/AS
ESE 510 VW
ESE 510 VW/AS
ESE 560 VW
ESE 560 VW/AS
ESE 590 VW
ESE 590 VW/AS
Accessories
Chassis
P OW E R S U P P LY SYS T E M S
Order No. 341 104 341 105 341 110 341 111 341 108 341 109 341 112 341 113
Total weight allowed in kg 1600 1600 2500 2500 3000 3000 3500 3500
One-axle/Tandem One-axle One-axle Tandem Tandem Tandem Tandem Tandem Tandem
Drawbar rigid adjustable rigid adjustable rigid adjustable rigid adjustable
Overrun brake yes yes yes yes yes yes yes yes
Available accessories
DIN pull eyelet 400 mm for lorry 341 501 341 501 341 503 – 341 503
Rear parking supports (1 pair) 341 500 341 500 341 500 341 500 341 500 341 500 341 500 341 500
ST = rigid drawbar with ball coupling for car HV = height adjustable drawbar, zinc-coated with ball coupling for car
Type series with DEUTZ engines FG 160 ST FG 160 HV FG 2500 ST FG 2500 HV FG 3000 ST FG 3000 HV FG 3500 ST FG 3500 HV
ESE 15 AS/MS
• •
ESE 20 AS/MS
• •
ESE 30 AS/MS
• •
68 ESE 40 AS/MS
• •
ESE 65 AS/MS
• •
ESE 80 AS/MS
• •
ESE 110 AS/MS
• •
ESE 145 AS/MS
• •
ESE 170 AS/MS
• •
P OW E R G E N E R AT O R S
und stopping - not retrofitable. Easy assembly with no need for drilling.
ACCESSORIES
additional protection for engine and alternator.
Insulation monitoring
According to ISO, a so-called “built ground” is no longer
necessary, regardless of which subsurface exists.
Consequently you can operate at each place of work
without further preparation. Even high-impedance insula-
tion faults are recorded securely and this leads automa-
tically to an immediate shut-down of the voltage.
The table below provides a quick survey of what genera- To define the optimal generator, add the performance
tor is the right choice for your consumers and your values of the consumers which you want to use simulta-
needs. The information is only for guidance and is not neously. Add 10% for ohmic consumers to obtain the
exhaustive. The power requirement of consumers correct generator rating. Take at least double the
depends on several factors and therefore no claims calculated value for inductive consumers such as
can be based on the table. electric motors.
AID TO SELECTION
Pages 16 - 20
ESE 30 BS
ESE 35 BS
ESE 40 BS
ESE 3000
Power
Household Voltage VA
Lighting 230 V 100- 500
Fridge 230 V 100- 200
Hotplate 230 V 600-2000 <1400 <1700
Fan heater 230 V 1000-2000 <1400 <1700
Hair drier 230 V 400-1500 <1400
70 Coffee machine
Electric tools
230 V 800-1600 <1400
Electric tools
Compressor 230 V 1000-2000 <1100 <1000 <1100 <1700 <1200 <1600
Compressor 400 V 1500-3000 <1800 <2400
Water pump 230 V 500-1500 < 800 <1000 <1200 <1400 <1200 <1300 <1400
Water pump 400 V 1500-3000 <2300
Circular saw bench 230 V 1000-2500 <1000 <1300 <1100 <1100 <1300 <1900 <1400 <1900
Circular saw bench 400 V 2500-4000 <2100 <2800
Inverter wel. device 400 V Ø mm 2,5 3,25 4,5 5,0
Chopper 230 V 800-2500 < 800 <1000 <1200 <1400 <1200 <1300 <1400 <2100 <2300 <2000
Lawn-mower 230 V 800-2000 <1000 <1200 <1400 <1700 <1500 <1500 <1700 <1800
AID TO SELECTION
ESE 1008 DHG ES Diesel Duplex Silent
G E N E R AT O R S
ESE 1002 DHG ES Diesel Duplex
71
1~ 1~ 1~
3~ 1~ 1~ 1~
3~ 1~ 3~
3~ 1~ 3~ 3~
ENDRESS units are subject to a permanent process of further development. Therefore ENDRESS reserves the right to make changes in the sense of a technical improvement.
Therefore technical information and illustrations are without obligation.
ENDRESS Elektrogerätebau GmbH
Neckartenzlinger Straße 39
D-72658 Bempflingen
Telefon +49 - (0 ) -71 23 - 97 37- 0
Telefax +49 - (0 ) -71 23 - 97 37- 50
e-mail info@endress-generators.de
Internet www.endress-generators.de