You are on page 1of 12

JUNE, 2007 2000 SKYLIGHT 1

E.C. 97903-09 FEATURES


entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
Laws and building and safety codes governing the design and use of glazed

Suitable for sloped glazed area, or roof mounted skylights

Integrates with standard 1600 vertical wall


and assumes no responsibility therefor.

Pressure equalized rain screen design

Simple overlap connections

"Shingled" internal channels for positive drainage

Integral purlin condensation gutters

Optional rafter condensation gutters

Tremco VISIONstrip ® exterior glazing system

Interior elastomeric glazing gaskets

Structural silicone glazed (SSG) option for purlins


Kawneer reserves the right to change configuration without prior notice when deemed

Three rafter depths for efficient structural design

Optional roll formed steel reinforcing channels

Veneer type mullion for use with steel sub-structure

Single glazing adapter for exterior canopies

Accommodates slopes from 20° to 45°

Full and half compression rings for pyramids and sloped gables
necessary for product improvement.

© Kawneer Company, Inc. 2007

Slope, gable, pyramid, and canopy construction available

Exterior / interior colour options

kawneer.com
2
BLANK PAGE
2000 SKYLIGHT
E.C. 97903-09

kawneer.com
JUNE, 2007

Kawneer reserves the right to change configuration without prior notice when deemed Laws and building and safety codes governing the design and use of glazed
necessary for product improvement. entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
© Kawneer Company, Inc. 2007 and assumes no responsibility therefor.
JUNE 2007 2000 SKYLIGHT 3
E.C. 97903-09 INDEX
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
Laws and building and safety codes governing the design and use of glazed

PICTORIAL VIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

SKYLIGHT TYPES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

DETAILS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 to 10
STRUCTURAL LIMITATIONS . . . . . . . . . . . . . . . . . . . . . . . 11, 12
and assumes no responsibility therefor.
Kawneer reserves the right to change configuration without prior notice when deemed

LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF
THIS PRODUCT VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION
AND USE OF THIS PRODUCT AND ASSUMES NO RESPONSIBILITY THEREFOR.
necessary for product improvement.

© Kawneer Company, Inc. 2007

Kawneer reserves the right to change or discontinue this product without notice.

kawneer.com
4
BLANK PAGE
2000 SKYLIGHT
E.C. 97903-09

kawneer.com
JUNE, 2007

Kawneer reserves the right to change configuration without prior notice when deemed Laws and building and safety codes governing the design and use of glazed
necessary for product improvement. entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
© Kawneer Company, Inc. 2007 and assumes no responsibility therefor.
Kawneer reserves the right to change configuration without prior notice when deemed Laws and building and safety codes governing the design and use of glazed
necessary for product improvement. entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
© Kawneer Company, Inc. 2007 and assumes no responsibility therefor.

kawneer.com
JUNE, 2007
E.C. 97903-09

OPTIONAL RAFTER
SIMPLE OVERLAP

CONDENSATION GUTTER
NOTCHES TO RAFTERS
CONNECTIONS WITH NO
2000 SKYLIGHT
PICTORIAL VIEW

INTEGRAL PURLIN
CONDENSATION GUTTER
5
6

1
9

7
5
6

3
3

2
1
SKYLIGHT TYPES

11
4

VERTICAL WITH SLOPE


2000 SKYLIGHT

RIDGE SKYLIGHT WITH SLOPED GABLE


7
3

2
10

PYRAMID SKYLIGHT

2
9

3
2

8
3
1

5
4

SINGLE SLOPE SKYLIGHT

RIDGE SKYLIGHT WITH VERTICAL GABLE


E.C. 97903-09

kawneer.com
JUNE, 2007

Kawneer reserves the right to change configuration without prior notice when deemed Laws and building and safety codes governing the design and use of glazed
necessary for product improvement. entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
© Kawneer Company, Inc. 2007 and assumes no responsibility therefor.
Kawneer reserves the right to change configuration without prior notice when deemed Laws and building and safety codes governing the design and use of glazed
necessary for product improvement. entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
© Kawneer Company, Inc. 2007 and assumes no responsibility therefor.

kawneer.com
8 1/4" (Nom.)
JUNE, 2007

209.6
E.C. 97903-09

7" (Nom.)

2
177.8

1 2

63
/"

82
.5
5 1/2" (Nom.)

2-0
34
139.7

82
SCALE 1/4 FULL SIZE

2-0
07

2
SILL
(Optional)
1
2 1/2"
63.5
216-103

822-001
822-002
822-003
216-051

RAFTER

822-120 Pressure Plate


822-031 Snap-on Cover
822-010

2
3"

1 2

63
/"
(Optional)

82
76.2

.5

2-0
34
4 1/2"

82
114.3

2-0

82
05
5 3/4"

O
Condensation Gutter

2-0
1

Co
0
146.1

( nd
on
pti ensa
al) tion

3
Gu

PURLIN
tte
r
Va
rie
s
82
2-1
21

82
2-0
05

4
HEAD
2000 SKYLIGHT
DETAILS
7
8

8
6
5
30° RIDGE

GABLE END
TRANSITION
30°

82
DETAILS

SCALE 1/4 FULL SIZE

2-1

82
21

82

2-0
2-0

34
09

82
2-0
07

822-002
216-103
216-051

FOR DETAILS OF 1600 WALL.


FOR DETAILS OF 1600 WALL.
2000 SKYLIGHT

NOTE: SEE CURTAIN WALL SECTION


NOTE: SEE CURTAIN WALL SECTION
Rafter
Sloped

822-002
822-001
Combinations
Rafter / Mullion

Mullion
Vertical

216-883
216-128

9
7
5

JAMB
45° RIDGE

HIP RAFTER
82
2-
45°

12
1
82
2-
00
822

9
-12
1

822-002

822-002
216-051
216-103
E.C. 97903-09

kawneer.com
JUNE, 2007

Kawneer reserves the right to change configuration without prior notice when deemed Laws and building and safety codes governing the design and use of glazed
necessary for product improvement. entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
© Kawneer Company, Inc. 2007 and assumes no responsibility therefor.
JUNE, 2007 2000 SKYLIGHT 9
E.C. 97903-09 DETAILS

SCALE 1/4 FULL SIZE


SSG OPTION
2 1/2"
63.5
216-103
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,

216-051
Laws and building and safety codes governing the design and use of glazed

5 1/2" (Nom.)
139.7
7" (Nom.)
8 1/4" (Nom.)

177.8
209.6

76.2
3"

114.3
4 1/2"

146.1
5 3/4"
822-003
and assumes no responsibility therefor.

822-002

822-001 822-010
(Optional) 21
2-1
Condensation Gutter 82

1
RAFTER
05
2-0
82

/"
3 4
.1
19
Va
rie
s
06
2-0
82

4
/"
3 4
HEAD
Kawneer reserves the right to change configuration without prior notice when deemed

.1
19

08
2-0 3
82
PURLIN

/"
3 4
.1
19

08
2-0
necessary for product improvement.

82
© Kawneer Company, Inc. 2007

2
SILL
216-051
216-103

6 Rafter / Mullion
TRANSITION Combinations
Sloped Vertical
Rafter Mullion

822-001 216-128
NOTE: SEE CURTAIN WALL SECTION
FOR DETAILS OF 1600 WALL. 822-002 216-883

NOTE: SEE 1600 SSG SECTION F2/B, PAGE 14 FOR NOTES REGARDING STRUCTURAL SILICONE SEALANT REQUIREMENTS AND
STRUCTURAL LIMITATIONS.

kawneer.com
10

3/8" 5 1/2" (Nom.)


9.6 139.7
DETAILS

SCALE 1/4 FULL SIZE

10
6 1/8"
155.6

RING

2 1/2"
63.5
216-103

822-004

822-013
216-051
COMPRESSION

VENEER RAFTER
2000 SKYLIGHT

H
ip
R
af
te
Rafter

H
ip
R
af
te
r
45°

822-015
2 1/2"
63.5
11
Rafter
6 1/8"
155.6

RING
HALF

Purlin detail similar


Rafter detail shown
COMPRESSION

822-015
45°

SINGLE GLAZING ADAPTER


3 1/16"
Rafter

77.8 CL

kawneer.com
E.C. 97903-09
JUNE, 2007

Kawneer reserves the right to change configuration without prior notice when deemed Laws and building and safety codes governing the design and use of glazed
necessary for product improvement. entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
© Kawneer Company, Inc. 2007 and assumes no responsibility therefor.
JUNE, 2007 2000 SKYLIGHT 11
E.C. 97903-09 STRUCTURAL LIMITATIONS

Calculations are based on CAN3-S157 "Strength Design in Aluminum" in accordance with the National Building Code of Canada,
considering combined service loads acting perpendicular to the glass plane and an allowable deflection of 1/175 of the span.

Determine the service dead, wind and live loads acting perpendicular to the glass plane for the required skylight slope. The greatest of the
following load combinations should be used to select the rafter required from the charts:

Deadload + Windload
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,

Deadload + Liveload
Deadload + 0.7 (Windload + Liveload)
Laws and building and safety codes governing the design and use of glazed

The information contained here is intended as a guideline only. Consult the National Building Code of Canada and / or local codes if more
detailed analysis is required.

WIDTH IN METRES WIDTH IN METRES WIDTH IN METRES


0.5 1.0 1.5 2.0 0.5 1.0 1.5 2.0 0.5 1.0 1.5 2.0
21 21 21

20 20 20
6.0 6.0 6.0
19 19 19
and assumes no responsibility therefor.

18 5.5 18 5.5 18 5.5


A
17 17 17
5.0 5.0 5.0
16 16 16

15 15 15 B
4.5 A 4.5 4.5
14 14 14
C
13 4.0 13 4.0 13 4.0
B D
12 12 12
3.5 C 3.5 E 3.5
11 A 11 11
D
F
10 3.0 10 3.0 10 3.0
B E
Kawneer reserves the right to change configuration without prior notice when deemed

9 C 9 9
F
D 2.5 2.5 2.5
LENGTH IN METRES

LENGTH IN METRES

LENGTH IN METRES
8 8 8
LENGTH IN FEET

LENGTH IN FEET

LENGTH IN FEET

E
7 7 7
F 2.0 2.0 2.0
6 6 6

5 1.5 5 1.5 5 1.5

4 4 4
1 2 3 4 5 6 7 1 2 3 4 5 6 7 1 2 3 4 5 6 7
WIDTH IN FEET WIDTH IN FEET WIDTH IN FEET
necessary for product improvement.

© Kawneer Company, Inc. 2007

76.2
3"

114.3
41/2"

146.1
5 3/4"

822-003

I = 3.15 in 4(1.31 x 10 6 mm 4 ) 822-002


S = 1.26 in 3 (2.06 x 10 4 mm 3 ) 822-001
I = 6.91 in 4 (2.88 x 10 6 mm 4 )
S = 2.20 in 3 (3.60 x 10 4 mm 3 ) I = 11.64 in 4 (4.85 x 10 6 mm 4 )
S = 3.15 in 3 (5.15 x 10 4 mm 3 )

A = 20 p.s.f. (0.96 kPa.) I = 1.25 in 4 (5.20 x 10 5 mm 4 )


B = 30 p.s.f. (1.44 kPa.) NOTE:
S = 0.71 in 3 (1.16 x 10 4 mm 3 ) THE CURVED LINES ON THE GRAPHS REPRESENT
C = 40 p.s.f. (1.92 kPa.) 822-005
D = 50 p.s.f. (2.40 kPa.) THE RAFTER LIMITATIONS. THE VERTICAL
E = 70 p.s.f. (3.36 kPa.) LINES REPRESENT THE MAXIMUM RAFTER
I = 0.79 in 4 (3.28 x 10 5 mm 4 ) CENTRES BASED ON THE PURLIN LIMITATIONS.
F = 90 p.s.f. (4.31 kPa.) S = 0.71 in 3 (1.17 x 10 4 mm 3 )
822-006

kawneer.com
12 2000 SKYLIGHT JUNE, 2007
STRUCTURAL LIMITATIONS E.C. 97903-09

Calculations are based on CAN3-S157 "Strength Design in Aluminum" in accordance with the National Building Code of Canada,
considering combined service loads acting perpendicular to the glass plane and an allowable deflection of 1/175 of the span.

Determine the service dead, wind and live loads acting perpendicular to the glass plane for the required skylight slope. The greatest of
the following load combinations should be used to select the rafter required from the charts:

Deadload + Windload

entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
Deadload + Liveload
Deadload + 0.7 (Windload + Liveload)

Laws and building and safety codes governing the design and use of glazed
The information contained here is intended as a guideline only. Consult the National Building Code of Canada and / or local codes if more
detailed analysis is required.

WIDTH IN METRES WIDTH IN METRES WIDTH IN METRES


0.5 1.0 1.5 2.0 0.5 1.0 1.5 2.0 0.5 1.0 1.5 2.0
24 24 24
A
23 7.0 23 7.0 23 7.0
A B A

and assumes no responsibility therefor.


22 22 22
C B
6.5 6.5 6.5
21 21 21
C D
20 20 20
B 6.0 6.0 6.0
19 19 19
D
18 C 5.5 18 5.5 18 E 5.5

17 17 17
D E
5.0 5.0 F 5.0
16 16 16

15 15 F 15
E 4.5 4.5 4.5
LENGTH IN METRES

LENGTH IN METRES

LENGTH IN METRES
14 14 14
LENGTH IN FEET

LENGTH IN FEET

LENGTH IN FEET

13 4.0 13 4.0 13 4.0


F

Kawneer reserves the right to change configuration without prior notice when deemed
12 12 12
3.5 3.5 3.5
11 11 11

10 10 10
1 2 3 4 5 6 7 1 2 3 4 5 6 7 1 2 3 4 5 6 7
WIDTH IN FEET WIDTH IN FEET WIDTH IN FEET
146.1

146.1

146.1

216-132 Steel 216-132 Steel 216-132 Steel


5 3/4"

5 3/4"

5 3/4"

Reinforcing 216-133 Reinforcing 216-133 Reinforcing


216-134

necessary for product improvement.


822-001 822-001 822-001

© Kawneer Company, Inc. 2007


Aluminum Aluminum Aluminum
I = 11.64 in 4 (4.85 x 10 6 mm 4 ) I = 11.64 in 4 (4.85 x 10 6 mm 4 ) I = 11.64 in 4 (4.85 x 10 6 mm 4 )
S = 3.15 in 3 (5.15 x 10 4 mm 3 ) S = 3.15 in 3 (5.15 x 10 4 mm 3 ) S = 3.15 in 3 (5.15 x 10 4 mm 3 )
Steel Steel Steel
I = 4.73 in 4 (1.97 x 10 6 mm 4 ) I = 8.54 in 4 (3.55 x 10 6 mm 4 ) I = 11.39 in 4 (4.74 x 10 6 mm 4 )
S = 1.94 in 3 (3.18 x 10 4 mm 3 ) S = 3.63 in 3 (5.95 x 10 4 mm 3 ) S = 5.01 in 3 (8.22 x 10 4 mm 3 )

A = 20 p.s.f. (0.96 kPa.) I = 1.25 in 4 (5.20 x 10 5 mm 4 )


B = 30 p.s.f. (1.44 kPa.) NOTE:
S = 0.71 in 3 (1.16 x 10 4 mm 3 ) THE CURVED LINES ON THE GRAPHS REPRESENT
C = 40 p.s.f. (1.92 kPa.) 822-005
D = 50 p.s.f. (2.40 kPa.) THE RAFTER LIMITATIONS. THE VERTICAL
E = 70 p.s.f. (3.36 kPa.) LINES REPRESENT THE MAXIMUM RAFTER
I = 0.79 in 4 (3.28 x 10 5 mm 4 ) CENTRES BASED ON THE PURLIN LIMITATIONS.
F = 90 p.s.f. (4.31 kPa.) S = 0.71 in 3 (1.17 x 10 4 mm 3 )
822-006

kawneer.com

You might also like