Professional Documents
Culture Documents
4-7 Cast iron or fabricated carbon 16-17 Separators are often installed ahead of
steam turbines to protect the
Eaton Gas/Liquid Separators
installed following intercoolers
are found. The units are highly
efficient for moisture separa-
or stainless steel construction tion of refrigerated air dryer
For applications with “liquid turbine blades from the and aftercoolers to remove
with flanged, threaded or packages.
slugs” and heavy liquid erosive action of wet steam, entrained moisture which
socket weld construction. pipe scale and other damage would otherwise cause
loading. Can be used as Compressed Gas
Many available options for causing entrained solids. They damage in successive stages
a flash or surge tank.
application versatility. are also installed in steam of compression or to subse- Eaton Gas/Liquid Separators
distribution lines to assure quent processes. They are also are often used in conjunction
clean, dry steam entering heat used for entrainment removal with intercooler and after-
exchangers, pressure reducing in primary air lines leading to cooler equipment installed on
Pages Type TS Vertical Types 31L-ST valves, temperature regulators, air using equipment such as gas compressors. They are
Gas/Liquid Pages Compact Gas/ meters and other process
equipment.
air chucks, air nozzles and
paint spray equipment. They
very effective in the removal
Pages Type 30L In-Line Pages Type DTL Dry this problem. The VCP utilizes
carefully placed rings that
Gas/Liquid Type Gas/Liquid shield the separated liquid
10-12 Separators 20-21 Separator from the vortex action inside
the separator and directs it to
For downflow or horizontal For applications with higher the separator drain. The turbu-
installations. Ten different than normal solids loading. A lence of the swirling gas or air
piping configurations available special conical shaped sump flow is sheltered from the
for application versatility. promotes solids collection at liquid and cannot be re-
The Exclusive
Separator B without the Vortex containment Plate
the drain port. entrained after separation.
The VCP features extremely
Eaton Vortex heavy duty construction of
stainless steel – unlike the
Page Type 60-I & 70-I Pages Type 40 Exhaust Containment delicate baffles used by
other systems. And the
Internal Type Gas/ Heads Plate (VCP) Eaton VCP is completely
13 Liquid Separator 22-23 Exhaust heads designed to maintenance free.
remove water and oil from The charts on the right graphi-
Internal separators designed
exhaust gases. Reduces main- cally show the high efficiency
to be installed inside of
tenance on roofs and of Eaton’s exclusive Vortex
receivers, steam drums, or
surrounding structures. Cast Containment Plate. They show
other vessels. Carbon or stain-
iron or fabricated carbon or the percent efficiency vs. air
less steel construction for
stainless steel construction in flow when the separator is Type 31-L separator with the Vortex Containment Plate (VCP)
both up flow and down flow
sizes to 48”. operated at 1 and 3 atm with
applications.
a water input rate of 150
Separator OPTIONS
• Integral Trap Dimensions - Type T (Cast Iron) – (in /mm)
• Trap Heating Element Pipe J - NPT Drains NPT Weight
Size A B C D Regular Opt’l Vent (lb/kg)
• ASME UM or U Code Stamp (CS and SS Models Only)
3 ⁄4 5.50 / 40 9.19 / 233 – 5.75 / 146 3⁄4 – 1⁄4 22 / 10
• Water Gauge Tap
1 6.00 / 152 9.00 / 229 – 6.75 / 171 1 1-1⁄4 1⁄4 25 / 11.4
• Thermometer Tap
1-1 ⁄4 6.00 / 152 9.13 / 232 – 7.00 / 178 1 1-1⁄4 1⁄4 28 / 12.7
Threaded
• Larger Drain Size
1-1⁄ 2 7.25 / 184 11.69 / 297 – 8.13 / 207 1 1-1⁄ 2 1⁄4 44 / 20
2 8.13 / 206 13.69 / 348 – 8.50/ 216 1 2 1⁄4 47 / 21.3
2-1⁄ 2 12.00 / 305 15.94 / 405 3.50 / 89 11.38 / 289 1-1 ⁄4 2 1⁄4 94 / 42.7
High Efficiency – clean, dry flow is then directed steel valve and seat. For Because they are constructed 3 11.00 / 281 15.94 / 405 3.50 / 89 11.38 / 289 1-1 ⁄4 2-1⁄ 2 1⁄4 90 / 41
No Maintenance to the outlet by the Vortex applications below freezing to specification they can be 1⁄4
2 10.50 / 267 13.75 / 349 – 8.50 / 216 1 2 47 / 21.3
Containment Plate. The VCP the Type ST Separator can be easily modified to suit unique
Flanged
The Eaton Type T Gas/Liquid 3 14.00 / 356 16.00 / 406 3.50 / 89 11.38 / 289 1-1 ⁄4 2-1⁄ 2 1⁄4 90 / 40.9
eliminates the need for expen- ordered as the Type STH that applications such as those that
Separator automatically
sive, delicate baffles used in includes a heater for the trap. require radially rotated inlet 4 15.88 / 403 19.38 / 492 5.00 / 127 14.06 / 357 1-1 ⁄4 2-1⁄ 2 1⁄4 195 / 88.6
removes 99% of all liquid and
ordinary separators. The heater is rated at 50W and outlet connections.
solid entrainment particles 10 Note: Threaded ends, NPT, Material ASTM A-278. Flanged ends, 125 lb ANSI flat face and drilling, Material ASTM A-278
and is for 110 volt service. The Fabricated separators are not
microns in size or larger from
Application Flexibility self limiting heating element as heavy as cast ones, an
air, gas, and steam processes.
will keep fluid above freezing important consideration in
And they do it with no moving The basic Type T Gas/Liquid and does not add to the line applications where weight is Dimensions - Type ST & STH – Threaded Inlet & Outlet (in /mm)
parts to wear out and with no Separator’s straight forward, temperature. The heater can be a concern. Cast or fabricated
required maintenance. The time proven design fits most Pipe Drain Vent Wt (lb/kg)
easily removed for inspection. Eaton Type T Gas/Liquid
Type T, with its cost effective applications without options. Size A B (ST) D NPT NPT ST STH
Separators let you choose the
design, is the separator of For more specialized applica- 3⁄4 5.5 / 40 11.69 / 297 6.75 / 171 3 ⁄4 1⁄4 31 / 14.1 34 / 15
Choose Cast or Fabricated best one for your application.
choice for most applications tions the Type T is available as 1 6.0 / 152 10.25 / 260 6.75 / 171 3 ⁄4 1⁄4 39 / 17.7 41 / 18.7
that require clean, dry air, Construction
the Type ST with an integral
gas or steam. We Can Help 1-1 ⁄4 6.0 / 152 12.25 / 311 7.00 / 178 3 ⁄4 1⁄4 47 / 21.3 50 / 22.3
trap as part of its design. The Type T Gas /Liquid Separators
trap mechanism is a fool-proof are available in sizes up to 4” Choosing the right gas/liquid 1-1⁄ 2 7.25 / 184 14.06 / 357 8.13 / 207 3 ⁄4 1⁄4 53/ 24 56 / 25
Exclusive Design design which automatically in cast iron and up to 2” in separator can present unique 2 8.13 / 206 14.94 / 380 8.50/ 216 3 ⁄4 1⁄4 58 / 26.3 61 / 27.3
ejects the condensate, with- cast carbon steel or cast stain- problems not encountered in
Moisture laden gas enters the 2-1⁄ 2 12.00 / 305 20.44 / 520 11.38/ 289 3 ⁄4 1⁄4 109 / 29.5 112 / 50.5
out loss of line pressure, less steel with standard choosing other pipeline
inlet of the separator where it 3 11.00 / 280 20.44 / 520 11.38 / 289 3 ⁄4 1⁄4 105 / 47.7 108 / 48.7
when it reaches a predeter- configurations. Cast construc- components. Why not take
is deflected in a centrifugal
mined level. The Type ST is tion separators are readily advantage of our over 100 Note: For steam service use hard valve seat only
downward motion. The
compact, easily installed and available but are not easy or years of application experience
entrained solids and moisture
can be supported by the line. cost effective to modify to with gas/liquid separators?
droplets are separated out by
Removal of the bottom flange conform to special application Application specialists are Dimensions - Type ST & STH - 125# Flanged Inlet & Outlet (in /mm)
a reduction in velocity.
releases the trap mechanism requirements. For these appli- available to help you every
Separated liquid and solids fall Pipe Drain Vent Wt (lb/kg)
for inspection. The internal trap cations see page 6 for step of the way. From initial Size A B (ST) D NPT NPT ST STH
into a reservoir where the
components are rust-proof Fabricated Type T Separators selection, to installation,
exclusive Vortex Containment 2 10.50 / 267 15.31 / 389 8.50/ 216 3 ⁄4 1⁄4 51 / 23.2 54 / 24.2
stainless steel and include a made of carbon or stainless through start-up… just
Plate (VCP) ensures that they 3 14.00 / 356 20.44 / 519 11.38 / 289 3 ⁄4 1⁄4 100 / 45.5 103 / 46.5
nonmagnetic 18-8 stainless steel in sizes up to 24”. contact us.
cannot be re-entrained. The 3 ⁄4 1⁄4
4 15.88 / 403 23.50 / 597 14.06 / 357 225 / 102.3 228 / 103.3
• Economical Choice for Most Applications 1-1⁄ 2 7.62 / 194 11.5 / 292 14 / 356 12.5 / 317 14 / 356 19 / 483 6.62 / 168 4.75 / 121 1 2 55 / 25 50 / 23 56 / 25 59 / 27
• Removes 99% of Liquid and Solid Entrainment 2 7.87 / 200 11.5 / 292 14 / 356 12.5 / 317 14 / 356 19 / 483 6.62 / 168 4.75 / 121 1 2 57 / 26 55 / 25 59 / 27 54 / 25
The Industry Particles Larger Than 10 Micron
• Gas, Steam or Air Applications
2-1⁄ 2 – 16 / 406 18 / 457 15 / 381 – 22 / 559 8.62 / 219 5.75 / 146 1 2 – 100 / 45 110 / 50 125 / 57
Standard 3 – 18 / 457 20 / 508 18 / 457 – 26 / 660 10.75 / 273 5.75 / 146 1-1⁄ 2 2-1⁄ 2 – 140 / 64 150 / 68 175 / 80
4 – 20 / 508 22 / 559 22 / 559 – 31 / 787 12.75 / 324 5.75 / 146 1-1⁄ 2 2-1⁄ 2 – 195 / 89 220 / 100 295 / 134
Gas/Liquid OPTIONS
5 – 22 / 559 24 / 610 26 / 660 – 36 / 914 14 / 356 7.87 / 200 1-1⁄ 2 2-1⁄ 2 – 230 / 105 290 / 132 435 / 198
• ASME UM or U Code Stamp
Separator • Hundreds of Design Options to 6 – 24 / 610 28 / 711 30 / 762 – 41 / 1041 16 / 406 7.87 / 200 1-1⁄ 2 2-1⁄ 2 – 350 / 159 380 / 173 715 / 325
Conform to Application Requirements 8 – 28 / 711 32 / 813 37 / 940 – 50 / 1270 18 / 457 7.87 / 200 2 3 – 475 / 216 610 / 277 1070 / 486
• Support Legs 10 – 34 / 864 38 / 965 55 / 1397 – 70 / 1778 24 / 610 7.87 / 200 2 3 – 780 / 355 1180 / 536 2065 / 939
12 – 38 / 965 42 / 1067 58 / 1473 – 75 / 1905 28 / 711 7.87 / 200 1-1⁄ 2 4* – 940 / 427 1510 / 686 2750 / 1250
14 – 42 / 1067 46 / 1169 60 / 1524 – 79 / 2007 32 / 813 7.87 / 200 2-1⁄ 2 4* – 1155 / 525 2205 / 1002 3400 / 1545
16 – 47 / 1194 51 / 1295 68 / 1727 – 89 / 2261 36 / 914 7.87 / 200 3 5* – 1605 / 730 2785 / 1266 4750 / 2159
High Efficiency – fall into a reservoir where Choose Cast or Fabricated We Can Help
No Maintenance the exclusive Eaton Vortex Construction 18 – 54 / 1372 58 / 1473 85 / 2159 – 109 / 2769 42 / 1067 9.12 / 232 3 5* – 2260 / 1027 4370 / 1986 6295 / 2861
Choosing the right gas/liquid
Containment Plate (VCP) separator can present unique 20 – 62 / 1575 66 / 1676 99 / 2515 – 126 / 3200 48 / 1219 9.12 / 232 3 5* – 2845 / 1293 5635 / 2561 8600 / 3909
The Eaton Type T Gas/Liquid Fabricated Type T Gas/Liquid
ensures that they cannot be problems not encountered in
Separator automatically Separators are available in 22 – 64 / 1626 68 / 1727 102 / 2591 – 130 / 3302 48 / 1219 10.25 / 260 3 5* – 3000 / 1364 6085 / 2766 10900 / 4955
re-entrained. The clean, dry choosing other pipeline
removes 99% of all liquid and sizes from 1” to 24” in carbon
flow is then directed to the components. Why not take 24 – 70 / 1778 74 / 1880 109 / 2769 – 140 / 3556 54 / 1372 10.25 / 260 4* 6* – 4295 / 1952 7845 / 3566 14000 / 6364
solid entrainment particles 10 steel or cast stainless steel
outlet by the Vortex advantage of our over 100
microns in size or larger from construction. Fabricated
Containment Plate. The VCP years of application experience
air, gas, and steam processes.
eliminates the need for
construction separators are * Flanged drain
And they do it with no moving built to order and can be easily with gas/liquid separators?
expensive, delicate baffles Application specialists are
parts to wear out and with no manufactured to exactly meet
used in ordinary separators. available to help you every
required maintenance. The the requirements of special
Type T, with its cost effective application or applications step of the way. From
design, is the separator of Application Flexibility where weight is a concern. initial selection, to installation
choice for most applications Fabricated separators, For standard applications cast and through start-up… just
that require clean, dry air, gas because they are separators are often the best contact us.
Capacities – Maximum Air Flow Rating in SCFM
or steam. manufactured one at a time, choice. See page 4 for Type T
can be made to fit the exact Gas/Liquid Separators in cast Pipe
Size 25 psig 50 psig 100 psig 150 psig 200 psig 250 psig
Exclusive Design requirements of unusual iron, carbon steel and stainless
3 ⁄4” 55 75 105 125 150 170
applications such as unique steel construction in sizes up
Moisture laden gas enters the to 4” with threaded, flanged 1” 82 110 155 190 220 255
size or piping connections.
inlet of the separator where or socket weld piping
They are also lighter in weight 1-1 ⁄4” 130 175 245 300 345 400
it is deflected in a centrifugal connections. Most standard
than a comparable size cast
downward motion. The cast separators are available 1-1⁄ 2” 185 245 345 425 485 560
separator. There are no trade-
entrained solids and moisture for shipment from stock. Cast 2” 330 445 620 770 870 1000
offs with a fabricated
droplets are separated out by or fabricated Eaton Type T Gas/
separator. You get the perfect 2-1⁄ 2” 500 680 945 1170 1350 1550
a reduction in velocity. Liquid Separators let you
unit for your application. You 3” 750 1000 1400 1750 1950 2300
Separated liquid and solids choose the best one for your
never have to pay for more
separator than you need application. 4” 1325 1775 2500 3075 3600 4000
or settle for a separator that 5” 2050 2750 3800 4750 5200 6000
won’t quite do the job you Rated ∆P (psi) 0.88 0.99 1.19 1.40 1.60 1.85
want it to.
High Efficiency – Exclusive Design connections. Depending on Dimensions – Type TS (Carbon Steel) with ANSI Flanges (in / mm)
No Maintenance the separator size liquid
– – – – – –Weight( lb/kg)– – – – – –
Moisture laden gas enters
Thd’d & 150 lb 300 lb
holdup capacities range from
The Eaton Type TS Gas/Liquid the inlet of the separator Threaded Socket Weld Flanges Flanges Liquid
0.19 cu. ft. to 32.64 cu. ft. or
Separator automatically where it is deflected in a Pipe & Skt Weld Flanged NPT Drain 1000 psig 150 psig 500 psig Holdup Cap.
larger should the application Size A A B C D F G Std Opt’l @ 650°F @ 450°F @ 650°F (cu ft/m)
removes 99% of all liquid and centrifugal downward motion.
require. The separators can be
solid entrainment particles 10 The entrained solids and 1 6.87/ 174 10.5 / 267 22 / 559 28 / 711 5.56 / 141 – 7.87 / 200 1 1-1⁄ 2 44 / 20 47 / 21 49 / 22 0.19 / 0.0053
furnished with an ASME Code
microns in size or larger from moisture droplets are sepa- 1-1⁄4 6.87 / 174 10.5 / 291 22 / 559 28 / 711 5.56 / 141 – 7.87 / 200 1 1-1⁄ 2 45 / 20 50 / 23 52 / 24 0.19 / 0.0053
Stamp as an option. Optional,
air, gas, and steam processes. rated out by a reduction in
integral support legs can also 1-1⁄ 2 7.87 / 200 11.5 / 292 24 / 610 30 / 762 6.62 / 168 9.12 / 232 9.12 / 232 1 2 83 / 38 69 / 31 75 / 34 0.20 / 0.0056
And they do it with no moving velocity. Separated liquid and
be specified.
parts to wear out and with no solids fall into a reservoir 2 7.87 / 200 11.5 / 292 24 / 610 30 / 762 6.62 / 168 9.12 / 232 9.12 / 232 1 2 85 / 39 74 / 34 78 / 36 0.20 / 0.0056
required maintenance. where the exclusive Eaton 2-1⁄ 2 – 16 / 406 27 / 686 35 / 889 8.62 / 219 9.12 / 232 9.12 / 232 1 2 – 122 / 55 132 / 60 0.39 / 0.011
Vortex Containment Plate Use Our Technical Support
(VCP) ensures that they can’t Services 3 – 18 / 457 30 / 762 38 / 965 10.75 / 273 9.12 / 232 9.12 / 232 1-1⁄ 2 2-1⁄ 2 – 170 / 77 180 / 82 0.66 / 0.018
Applications
be re-entrained. The clean, Choosing the right gas/liquid 4 – 20 / 508 36 / 914 45 / 1143 12.75 / 324 10.25 / 260 10.25 / 260 1-1⁄ 2 2-1⁄ 2 – 225 / 102 250 / 114 1.07 / 0.03
The Eaton Type TS gas/liquid dry flow is then directed to separator can present unique 5 – 22 / 559 40 / 1016 50 / 1270 14 / 356 10.25 / 260 10.25 / 260 1-1⁄ 2 2-1⁄ 2 – 265 / 120 335 / 152 1.35 / 0.04
separator is designed for appli- the outlet by the Vortex problems not encountered in 6 – 24 / 610 55 / 1397 66 / 1676 16 / 406 10.25 / 260 10.25 / 260 1-1⁄ 2 2-1⁄ 2 – 400 / 182 435 / 198 3.03 / 0.084
cations where heavier than Containment Plate. The VCP choosing other pipeline
normal liquid loading causes eliminates the need for 8 – 28 / 711 62 / 1575 75 / 1905 18 / 457 11.87 / 301 11.87 / 301 2 3 – 545 / 248 700 / 318 3.83 / 0.107
components. Especially when
a “slugging” problem. These expensive, delicate baffles dealing with high liquid loading 10 – 34 / 864 76 / 1930 91 / 2311 24 / 610 11.87 / 301 11.87 / 301 2 3 – 800 / 364 1355 / 616 6.94 / 0.194
applications are widely found used in ordinary separators. applications. Why not take 12 – 38 / 965 82 / 2083 99 / 2515 28 / 711 11.87 / 301 11.87 / 301 2-1⁄ 2 4* – 1090 / 495 1735 / 789 11.74 / 0.33
in refineries and chemical
advantage of our over 100
plants. In many cases, there 14 – 42 / 1067 89 / 2261 108 / 2743 32 / 813 12.62 / 321 12.62 / 321 2-1⁄ 2 4* – 1335 / 607 2535 / 1152 16.81 / 0.47
Fabricated Construction years of application experience
is a liquid holdup requirement 16 – 47 / 1194 98 / 2489 119 / 3023 36 / 914 12.62 / 321 12.62 / 321 3 5* – 1850 / 841 3200 / 1455 20.22 / 0.57
with gas/liquid separators?
where instrumentation is The Type TS Separator is
Application specialists are 18 – 54 / 1372 108 / 2743 132 / 3353 42 / 1067 12.62 / 321 12.62 / 321 3 5* – 2600 / 1182 5025 / 2284 22.99 / 0.64
provided for controlling the available in fabricated carbon
available to help you every
level of the liquid in the reser- steel, stainless steel or other 20 – 62 / 1575 118 / 2997 145 / 3683 48 / 1219 15 / 381 15 / 381 3 5* – 3275 / 3275 6480 / 2945 26.47 / 0.74
step of the way. From initial
voir of the vessel. Some alloy construction with socket 22 – 64 / 1626 121 / 3073 149 / 3785 48 / 1219 15 / 381 15 / 381 3 5* – 3450 / 1568 7000 / 3182 26.47 / 0.74
selection, to installation and
common applications include weld, threaded and 150#,
through start-up… just 24 – 70 / 1778 127 / 3226 158 / 4013 54 / 1372 15 / 381 15 / 381 4* 6* – 4940 / 2245 9020 / 4100 32.64 / 0.91
upstream of gas turbines, 300# and 600# flange
contact us.
absorption towers, steam
generator outlets and gas
Note: Type TS separators are of welded steel construction in accordance with ASME code for * Flanged drain
scrubbers.
unfired pressure vessels. Available in stainless steel on request. Inlet and outlet connections can be
rotated radially, if specified.
FEATURES
10 Models • Compact Design
Type 31-L (Standard Model) Type 31-L S with Optional Sump Type 32-L Vertical Upflow Separator
OPTIONS
• Oversize Inlet Connections
• Reduced Size Inlet and Outlet Connections
• Different Flow Patterns Series 30L Separators with Offset Piping Connections
• Integral Sump
• ASME Code Stamp
• Support Legs
Type 31-L
Type 31-LS
Type 33-L Vertical Type 37-L Vertical Type 35-L Vertical Upflow
Downflow with Offset Upflow with Offset with Offset Inlet
Outlet Outlet
W 24.00 26.00 26.00 29.00 36.00 41.00 45.00 58.00 68.00 79.00 89.00 99.00 109.00 118.00 131.00 144.00 163.00 177.00 189.00 222.00 255.00 24 36 / 914 35 / 889 17.5 / 444 8 / 203 30 / 762 2-1⁄ 2 350 / 770 3 275 / 125
610 660 660 737 914 1041 1143 1473 1727 2007 2261 2515 2769 2997 3327 3658 4140 4496 4801 5639 6477
26 39 / 991 38 / 965 18 / 457 9 / 229 32.5 / 825 2-1⁄ 2 455 / 1001 3 340 / 155
X 18.00 20.00 20.00 22.00 28.00 32.00 35.00 46.00 54.00 53.00 71.00 80.00 87.00 95.00 108.00 117.00 131.00 143.00 153.00 180.00 207.00
457 508 508 559 711 813 889 1168 1372 1346 1803 2032 2210 2413 2743 2972 3327 3632 3886 4572 5258 28 42 / 1067 40 / 1016 18.5 / 470 9.5 / 241 35 / 889 2-1⁄ 2 575 / 1265 4 385 / 175
Y 25.00 27.00 27.00 31.00 38.00 43.00 46.00 59.00 67.00 78.00 87.00 96.00 105.00 113.00 126.00 138.00 155.00 167.00 180.00 210.00 244.00
635 686 686 787 965 1092 1168 1499 1702 1981 2210 2438 2667 2870 3200 3505 3937 4242 4572 5334 6198
Z 18.00 20.00 20.00 22.00 28.00 32.00 34.00 45.00 51.00 60.00 67.00 75.00 81.00 88.00 99.00 109.00 122.00 133.00 144.00 168.00 194.00
457 508 508 559 711 813 864 1143 1295 1524 1702 1905 2057 2235 2515 2769 3099 3378 3658 4267 4928
Drain NPT 1.00 1.00 1.00 1.50 1.50 1.50 1.50 2.00 2.00 2.50 2.50 3.00 3.00 4.00* 4.00* 4.00* 4.00* 4.00* 4.00* 4.00* 4.00*
Maximum • Gas, Steam or Air Applications 6 48 / 102 40 / 1016 4 / 102 14 / 356 1-1⁄ 2 510 / 232
• ASME Code Stamp 14 78 / 127 68 / 1727 5 / 127 28 / 711 2-1⁄ 2 1830 / 832
16 86 / 127 76 / 1930 5 / 127 30 / 762 3 2130 / 968 Horizontal inlet and outlet
See Steam and Air Charts for sizing information.
Type 36L with
Vertical Upflow
Type 35L with Inlet and Dimensions - Type 36L-CLC (in/mm)
Side Inlet for Horizontal Outlet
Vertical Upflow Pipe Drain Wt
Size C D T W X NPT (lb/kg)
2-1⁄ 2 3 / 76 6.62 / 168 7 / 178 37 / 940 30 / 762 1 130 / 59
3 3 / 76 8.62 / 219 8 / 203 41 / 1041 33 / 838 1-1⁄ 2 165 / 75
4 4 / 102 10.75 / 273 10 / 254 44 / 1118 36 / 914 1-1⁄ 2 295 / 134
Most Efficient Design Type steam, compressed air prior
to desiccant dryer beds, high 5 4 / 102 12.75 / 324 11 / 279 51 / 1295 41 / 1041 1-1⁄ 2 420 / 191
The unique two stage design Type 31L for
pressure gas at injection wells, Horizontal or 6 4 / 102 14 / 356 12 / 305 54 / 1372 42 / 1067 1-1⁄ 2 475 / 216
of these separators allows
fuel gas lines to engines in Vertical Downflow
them to remove 99% of all 8 5 / 127 16 / 406 13 / 330 66 / 1676 53 / 1346 2 525 / 239
power and industrial plants, Applications
liquid and solid particles larger
natural gas and gas distribu- 10 5 / 127 20 / 508 15 / 381 77 / 1956 60 / 1524 2 590 / 268
than 4 microns in size.
tion lines or regulator stations.
Standard, one stage separa- 12 5 / 127 24 / 610 17 / 432 88 / 2235 70 / 1778 2-1⁄ 2 1125 / 511
tors are only capable of Easy Maintenance
removing particles larger than Two-Stage Design 14 5 / 127 28 / 711 19 / 483 96 / 2438 77 / 1956 2-1⁄ 2 1475 / 670
Vertical upflow inlet horizontal outlet
10 micron in size. The Eaton The operation of an Eaton The only maintenance required 16 5 / 127 30 / 762 20 / 508 101 / 2565 80 / 2032 3 1925 / 875
Coalescer/Separator efficiency Coalescer/Separator can be is the inspection, cleaning, or
far exceeds that of any other divided into two stages. In the replacement of the de-misting
type of centrifugal, cyclone, first stage, the coalescer pad. This is easily accomplished
turbine or vane type separator. through either a quick opening Dimensions - Type 35L-CLC (in/mm)
stage, the smaller liquid
And they do it with no moving droplets enter a special wire body closure or body flanges. Pipe Drain Wt
parts to fail or wear out. mesh de-misting pad in the Size C L O P Q NPT (lb/kg)
vessel. The purpose of this Engineering Specification 2-1⁄ 2 3 / 76 8.62 / 219 30 / 762 24 / 610 8 / 203 1 145 / 66
Applications pad is to increase the size of All gas/liquid separators shall 3 3 / 76 10.75 / 273 34 / 864 28 / 711 9 / 229 1-1⁄ 2 195 / 89
the droplets as they pass be of fabricated carbon steel
The Eaton Coalescer/Separator 1-1⁄ 2
through it so that they can be construction with two stage
4 4 / 102 14 / 356 39 / 991 31 / 787 11 / 279 305 / 139
is a two-stage vessel designed
removed. The larger liquid coalescer/separator design 5 4 / 102 16 / 406 45 / 1143 35 / 889 12 / 305 1-1⁄ 2 435 / 198
for separation of liquid in the
droplets exit the de-misting with flanged connections.
form of a fine mist or fog from 6 4 / 102 18 / 457 50 / 1270 39 / 991 13 / 330 1-1⁄ 2 530 / 241
pad and enter the second, Separators shall have ASME
a gas or vapor. The coalescer/
separation, stage. Here the Code Stamp. Separators shall 8 5 / 127 20 / 508 56 / 1422 45 / 1143 15 / 381 2 665 / 302
separator is primarily used in
droplets are centrifugally be designed to remove 99%
applications where fine mist is 10 5 / 127 24 / 610 67 / 1702 53 / 1346 17 / 432 2 975 / 443
thrown to the outside wall by of entrained liquid or solid
encountered in processes
a unique Cenpellar™ and flow particles larger than 4 microns 12 5 / 127 30 / 762 76 / 1930 61 / 1549 19 / 483 2-1⁄ 2 1390 / 632
involving cooling, condensa-
to the bottom of the vessel for in size when correctly
tion, flashing or evaporation. 14 5 / 127 36/ 914 86 / 2184 67 / 1702 23 / 584 2-1⁄ 2 1920 / 873
draining. The Eaton Vortex installed. Separator to have a
Some examples of applica-
Containment Plate (VCP) Vortex Containment Plate to 16 5 / 127 40 / 1016 98 / 2489 77 / 1956 25 / 635 3 2645 / 1202
tions are separating liquid, Horizontal inlet vertical upflow outlet
prevents the droplets from prevent re-entrainment of
such as water or oil from:
being re-entrained after solids and liquids. Separators
compressed refrigeration
separation. to be Eaton Series CLC.
gases, evaporator overhead
The Eaton standard size Type Principle of Operation Construction We Can Help 10 10 34 / 864 64 / 1626 5 / 127 24 / 610 35 / 889 17 / 432 35 / 889 74 / 1880 45 / 1143 40 / 1016 40 / 1016 69 / 1753 7.875 / 200 2
10-R Series Separators are 12 12 38 / 965 72 / 1829 5 / 127 30 / 762 39 / 991 19 / 483 38 / 965 82 / 2438 51 / 1295 44 / 1118 44 / 1118 77 / 1956 7.875 / 200 2-1⁄ 2
Eaton Type 10-R Series Type R Separators are Choosing the right gas/liquid
designed for liquid slugs or 2-1⁄ 2
Separators have two stages constructed in accordance separator can present unique 14 14 42 / 1067 80 / 2032 5 / 127 36 / 914 41 / 1041 21 / 533 42 / 1067 90 / 2083 55 / 1397 46 / 1168 46 / 1168 85 / 2159 7.875 / 200
heavy liquid loads and can be
for separating large volumes with the ASME Code Section problems not encountered in 16 16 46 / 1168 88 / 2235 5 / 127 40 / 1016 44 / 1118 23 / 584 45 / 1143 98 / 2489 60 / 1524 48 / 1219 48 / 1219 93 / 2362 7.875 / 200 3
provided with a large reservoir
of liquid from a smaller volume VIII, Division 1 and are code choosing other pipeline
to meet liquid holdup require-
of a gas or vapor. In stage one, stamped. They are available components. Why not take
ments. For applications where
the flow enters the inlet and is with 150# slip on raised face advantage of our over 100
space is restricted, a compact
model is available. deflected downward by the flanges rated at 200 psi at years of application experience 10-R Series With Offset Piping Connections
impingement plate causing it 300°F or with 300# slip on with gas/liquid separators?
Application specialists are
Applications to loose velocity. This results raised face flanges rated at TYPE 10-R TYPE 11-R TYPE 12-R TYPE 14-R
available to help you every
in the majority of the liquid 250 psi at 650°F. They feature
Type 10-R Series Separators step of the way… from
dropping into the reservoir. In fabricated carbon steel
are widely used in the initial selection, to installation
the second stage the moisture construction and with internal and through start-up…just
chemical and process indus- laden gas passes through a vane blades made of 304L
tries where large volumes of contact us.
vane element where the stainless steel.
liquid must be separated from remaining moisture is sepa-
gases. They also may be used rated and flows down to the See Pages 26 and 28 for Air and
as a flash or surge tank, or as reservoir. The separator will Steam Capacity Charts
a scrubber or de-mister ahead remove all liquid and solid
of steam turbines. entrainment where the particle
size is 10 microns or greater.
FEATURES
Low Profile Design • Light Weight, Compact Dimensions – Type 31L-ST Flanged (in/mm)
Liquid
Discharge (lb/hr) 265 790 427 1273 625 760 590 650
* 5 / 64” Orifice available for pressures up to 250 psig, but code stamp not available over 160 psig.
OPTIONS
• Larger Sizes
• Code Stamp
Type T-DTL
Type T-DTL Type 33L-DTL Type 31L-DTL
Helps Reduce
Roof Maintenance FEATURES
Costs • Choice of Cast or Fabricated Construction
• Removes 99% of Liquid and Solid Entrainment
Particles Larger Than 10 Microns
• No Required Maintenance
• Highly Efficient
• Virtually No Back Pressure Cast Iron-Type 40EHC Fabricated Carbon or Stainless Steel - Type 40EHMF
Threaded Inlet
1-1 ⁄ 2 5.25 / 133 6.12 / 156 1 ⁄ 2 – 11 / 5 370 100
2, 2-1 ⁄ 2 7.5 / 190 8.87 / 225 3 ⁄4 – 25 / 12 1,000 280
3 8.75 / 222 11.25 / 286 3 ⁄4 – 40 / 18 2,100 500
4 10 / 254 11.87 / 392 1 – 50 / 23 2,700 700
4 10 / 254 15 / 381 1 9 / 229 68 / 31 2,700 700
Flanged Inlet
5 13/ 330 14 / 356 1-1 ⁄ 2 10 / 254 90 / 41 4,000 1,100
6 14.75 / 375 18.75 / 476 1-1 ⁄ 2 11 / 279 115 / 52 6,000 1,700
Type 40EHMF
Type 40EHC (fabricated) 8 18 / 457 20 / 508 2 13.5 / 343 190 / 86 10,500 2,900
(cast)
10 23/ 584 24 / 610 2 16 / 406 335 / 152 16,000 4,500
Eaton Exhaust Heads are Type 40EHC Exhaust Head Type 40EHMF Exhaust Head
designed to separate entrained Rugged Cast Construction Fabricated Carbon or Dimensions - Type 40EHMF (in / mm)
water and oil from exhaust air, Stainless Steel Construction Capacity (lb) Capacity (SCFM)
The Eaton Type 40EHC
gas or steam prior to being Exhaust Stream/Hr at Exhaust Air at
exhaust head is designed for The Eaton Type 40EHMF
discharged directly into the Pipe Diameter Drain Weight Atmospheric Atmospheric
long service life… with body, exhaust head muffler is fabri- Size of Outlet A B Size Type (lb/kg) Pressure (14.7 psia) (14.7 psia)
atmosphere. They will remove
cover and separating element cated from carbon or stainless
more than 99% of liquids and 2-1⁄ 2 2.5 / 63 8.62 / 219 16 / 406 1 NPT 55 / 25 1,000 280
made of high tensile strength steel and is electrically welded
solids over 10 microns in size
cast iron. Sizes 4” and smaller at all joints to withstand heavy 3 3 / 76 10.75 / 273 19 / 483 1-1⁄ 2 NPT 65 / 30 1,600 410
from the discharged flow,
have threaded (NPT) connec- duty usage. These exhaust
reducing maintenance costs 4 4 / 102 14 / 356 24 / 610 1-1⁄ 2 NPT 100 / 45 2,700 700
tions. Sizes 3”, 4” and larger heads work at high tempera-
on roofs and surrounding
have 125# flanged connec- tures and remain efficient even 5 5 / 127 16 / 406 26 / 660 1-1⁄ 2 NPT 130 / 59 4,000 1,100
objects.
tions. The flange bolt holes are when steam or gas is 6 6 / 152 18 / 457 30 / 762 1-1⁄ 2 NPT 140 / 64 6,000 1,700
drilled to straddle the center discharged at high velocities.
Operation line of the drain outlet. The Type 40EHMF has been 8 8 / 203 20 / 508 36 / 914 2 NPT 240 / 109 10,500 2,900
The moisture laden gas, air or Flanges are cast integral with designed to minimize the 10 10 / 254 24 / 610 42 / 1,067 2 NPT 390 / 177 16,000 4,500
steam enters at the inlet of the body and have slotted noise associated with high
the exhaust head where it is holes which are recessed to discharge velocities. 12 12 / 305 30 / 762 48 / 1,219 2-1⁄ 2 NPT 550 / 250 24,000 6,500
directed into a centrifugal prevent the bolt heads from The units permit free flow of 14 14 / 356 36 / 914 54 / 1,372 2-1⁄ 2 NPT 700 / 341 34,000 8,800
upward motion. The entrained turning (except for the 3” and steam, gas or vapors with an
4” sizes which are available 16 16 / 406 40 / 1,016 60 / 1,524 3 NPT 850 / 386 44,000 11,500
solids and moisture droplets absolute minimum of back
are separated out by a reduc- with flanged or threaded pressure. They feature a sepa- 18 18 / 457 42 / 1,067 66 / 1,676 3 NPT 1,175 / 534 52,000 14,500
tion in velocity. Separated connections). rating element of 304/304L 20 20 / 508 48 / 1,219 72 / 1,829 3 NPT 1,500 / 682 66,000 17,000
material falls into a drain stainless steel and the entire
reservoir. exhaust head can be ordered 24 24 / 610 54 / 1,372 84 / 2,134 4 Flanged 1,850 / 841 94,000 26,000
in 304L or 316/316L stainless 30 30 / 762 72 / 1,829 102 / 2,591 4 Flanged 2,100 / 955 145,000 40,000
steel if required.
36 36 / 914 78 / 1,981 112 / 2,845 4 Flanged 4,500 / 2,045 210,000 55,000
42 42 / 1,067 96 / 2,438 130 / 3,302 4 Flanged 6,100 / 2,773 290,000 76,000
48 48 / 1,219 102 / 2,591 148 / 3,760 4 Flanged 7,800 / 3,545 375,000 99,000
250 1.206
EXPLANATION OF SYMBOLS 300 1.256
400 1.353
Fg =Correction factor for
specific gravity (see table 500 1.445
at far right)
550 1.490
Ft =Correction factor for
1 psi = 2.036” Hg
600 1.533
temperature (see table at 1” Hg = .4912 psi
right) 700 1.618
800 1.701
1 psi = 27.71” H2O
G =Specific gravity
900 1.780 1” H2O = .03613 psi
MMSCFD =Million standard cubic
feet per day 1000 1.858
MW =Molecular weight
Pa =Pressure (psia) at which
volume is measured
Qa =Rate of flow-standard
cubic feet per minute
(ACFM)
Qc =Rate of flow-standard
cubic feet per minute of
equivalent air
Qsg =Rate of flow-standard
cubic feet per minute
T =Operating temperature
(oF)
Operating Pressure in PSIA
Ta =Temperature (oF) at which
volume is measured
W =Rate of flow-pounds per
hour
Address:__________________________________________________________________________________________________
E-Mail: ___________________________________________________________________________________________________
Product(s) of Interest
Cast ST and T Type Separators Fabricated L and T Type Separators Exhaust Heads
Application Parameters
Pounds Per Hour of Steam
REDUCED PRESSURE
DROP AND NO LOSS
USE 1” SIZE WITH
OF EFFICIENCY
Operating Pressure in PSIA Materials of Construction: Cast Iron Carbon Steel 304L SS 316L SS
Other__________________________________________________________________________________________
Mechanically-Cleaned Filters
A green solution for the auto-
matic removal of debris from
liquids with no bags to buy,
change or landfill.
• Tubular Backwash
• Magnetically Coupled
EF-WAPG