Professional Documents
Culture Documents
WORKS 2006-07
X.INTERNAL-PH
Page 1
NO CODE DESCRIPTIONS UNIT RATE
C) 15mm heavy quality flexible PVC inlet
connection with CP brass hexagonal check nuts
and washers at both ends. D) Black plastic seat
and cover of approved make with CP pillar hinges
conforming to IS:2548 E) 15mm n.b. CP brass
angle-cock/stop cock conforming to IS:781 of
approved make with a minimum weight of 400gms
on the inlet to the cistern. F) 15mm GI over flow
pipe with CP brass mosquito proof jali and ckeck
nuts. Complete all as specified above with
approved fittings. (Refer fig. No. CED:PH:1.1 of
specifications for PH Engg works).
Page 2
NO CODE DESCRIPTIONS UNIT RATE
C) 32mm n.b. PVC flush pipe of heavy quality of
required length with necessary check nuts from
the cistern to the WC inlet and making necessary
connections, concealed in the wall, etc. D) 15mm
size heavy quality flexible PVC inlet pipe
connection with CP brass check nuts with
washers at both ends E) 15mm n.b. CP brass
angle-cock/stop cock conforming to IS:781 of
approved make with a minimum weight of 400gms
on the inlet to the cistern. F) 15mm n.b. medium
quality GI overflow pipe with specials from the
cistern to 15cms above the floor, concealed in
wall terminated with CP brass mosquito proof jali.
Complete all as specified above with approved
fittings. (Refer fig. No. CED:PH:1.2 of
specifications for PH Engg works).
Page 3
NO CODE DESCRIPTIONS UNIT RATE
5A X025A X.05.1) With 'S' trap EACH 2782.25
Page 4
NO CODE DESCRIPTIONS UNIT RATE
Page 5
NO CODE DESCRIPTIONS UNIT RATE
F) 15mm n.b. medium quality GI overflow pipe
with specials from the cistern to 15cms above the
floor, concealed in wall terminated with CP brass
mosquito proof jali. Complete all as specified
above with approved fittings. (Refer fig. No.
CED:PH:1.2 of specifications for PH Engg works).
Page 6
NO CODE DESCRIPTIONS UNIT RATE
9 X045 X.09) Providing and Fixing Indian Style Water
Closet Suite (With foot rests and flush valve)
Comprising of : A) Indian water closet white
glazed vitreous chinaware of approved make
580mm long with trap as mentioned below and
with a pair of foot rests conforming to IS:2556
part-III part-X bearing ISI mark fixed to floor
including cutting and making good etc. B) CP
open type flush valve, having inlet 25mm and
outlet 32mm, consisting of CP brass wall flange
with adjustable screw for control of flow of water
of approved make.
Page 7
NO CODE DESCRIPTIONS UNIT RATE
G) One 32mm medium quality GI waste pipe with
specials from extension piece of the bottle trap to
the floor trap, length not exceeding 1 mtr
concealed in wall. H) One no. 40mm GI bend and
40mm dia 250mm long GI pipe connection waste
pipe to floor trap. All as per specifications and as
directed with approved fittings. (Refer fig. No.
CED:PH:1.4 of specifications for PH Engg works)
Page 8
NO CODE DESCRIPTIONS UNIT RATE
12 X060 X.12) Providing and Fixing Best Indian make
wash hand basin (with PVC waste pipe)
Comprising of : A) Best Indian make white
glazed vitreous chinaware wash hand basin of
approved make of size mentioned below
conforming to IS:2556 Part-IV with single tap hole
and bearing ISI mark supported on a pair of
painted CI brackets conforming to IS:775. B)
One 15mm CP brass pillar cock of approved
make with hot or cold water indication as required
conforming to IS:1795 with minimum weight of
577gms.
13 X065A X.13) Providing and Fixing in position large urinal EACH 3111.35
comprising of : A) White glazed vitreous
chinaware of approved make large urinal of size
600X400X375mm with necessary fixtures
conforming to IS : 2556 Part-VI bearing ISI mark.
B) 15mm n.b.CP brass concealed stop cock of
approved make conforming to IS:781 on flushing
line one for each urinal in the range. C) CP
brass distribution pipe and spreader of best
approved quality to the urinal with necessary CP
brass specials, clamps etc., one for each urinal in
a range. D) One number 32mm CP brass waste
coupling-one for each urinal E) One number
32mm PVC waste pipe and specials from each
urinal to floor trap / half round channel.
Complete all as specified with approved fittings.
Page 9
NO CODE DESCRIPTIONS UNIT RATE
14 X070A X.14) Providing and Fixing in position Flat back EACH 1991.9
urinal comprising of : A) White glazed vitreous
chinaware of approved make Flat back urinal of
size 430mmX300mm with necessary fixtures
conforming to IS : 2556 Part-VI bearing ISI mark.
B) 15mm n.b.CP brass concealed stop cock of
approved make conforming to IS:781 on flushing
line one for each urinal in the range. C) CP
brass distribution pipe and spreader of best
approved quality to the urinal with necessary CP
brass specials, clamps etc., one for each urinal in
a range. D) One number 32mm CP brass waste
coupling-one for each urinal E) One number
32mm PVC waste pipe and specials from each
urinal to floor trap / half round channel.
Complete all as specified with approved fittings
15 X075A X.15) Providing and Fixing best Indian make EACH 3264.45
kitchen sink with drain board comprising of : A)
Best Indian make glazed fire clay kitchen sink of
approved make of size 600 X 450 X 250mm and
drain board of size 600 X 450mm conforming to
IS:771 Part-II supported on painted CI brackets
conforming to IS:775 B) One 40mm Heavy
quality CP brass waste coupling C) One 32mm
PVC waste pipe bent to shape length not
exceeding 1m to discharge in to the floor trap
through GI elbow. D) 40mm GI Medium class
pipe 250mm long connecting elbow to floor trap.
Complete all as specified with approved fittings.
(Ref. Fig.No.CED:PH1.6(A) of PH Engg.
Specification
16 X080A X.16) Providing and Fixing best Indian make EACH 2534.95
kitchen sink without drain board comprising of :
A) Best Indian make glazed fire clay kitchen sink
of approved make of size 600X450X250mm
conforming to IS:771 Part-II supported on painted
CI brackets conforming to IS:775 B) One 40mm
Heavy quality CP brass waste coupling C) One
32mm PVC waste pipe bent to shape length not
exceeding 1m to discharge in to the floor trap
through 40mm GI elbow, 40mm Dia 250mm long
GI medium class pipe connecting to floor trap.
Complete all as specified with approved fittings.
(Ref. Fig.No.CED:PH1.6 of PH Engg.
Specification)
Page 10
NO CODE DESCRIPTIONS UNIT RATE
17 X082A Providing and fixing granite sink of size SQM 0
750x450x300mm oval shape including making
hole for fixing the waste coupling, etc; complete.
18A X085A X.17.1) Discharging into the floor trap through a EACH 581.1
40mm GI bend & pipe of 40mm GI Medium class
pipe connecting floor trap.
18B X085B X.17.2) Discharging into floor drain/half round EACH 349.6
channel
Page 11
NO CODE DESCRIPTIONS UNIT RATE
21 X100A X.20) Providing and Fixing in position vitreous EACH 265.5
chinaware 150X150mm recess type soap tray of
approved make with necessary CP screws and
washers fixed into the wall including cutting the
wall, fixing and making good the surface etc,
Complete all as specified and directed.
22 X105A X.21) Providing and Fixing in position best Indian EACH 939.4
make Marble partition slab for urinals, size
610X1150mm, 20mm thick (tolerance + \ - 1mm)
polished on both sides and machine cut edges
with exposed corners rounded etc all as specified
and directed. (Ref. Fig.No.CED:PH1.5 of PH
Engg. Specification)
23 X110A X.22) Providing and Fixing in position best quality EACH 616.35
approved make Mirror of size 550X400mm
mounted on 6mm thick plain asbestos sheet
backing with 4no.s of CP brass cap screws and
washers fixed to walls with necessary plugs etc.
all specified and directed. (Ref.
Fig.No.CED:PH1.4 of PH Engg. Specification)
Page 12
NO CODE DESCRIPTIONS UNIT RATE
28A X135A X.27.1.1) CP brass towel rail of 600 mm long. EACH 364.9
28B X135B X.27.1.2) CP brass towel rail of 450 mm long. EACH 256
29 X140A X.28) Providing and Fixing in position best quality EACH 132.2
approved Indian make double type CP brass coat
and hat hooks with flanges fixed to wall/door
shutter etc. with necessary screws, washers and
plugs all as specified and directed.
30B X150B X.29.2) Swivel type with shower arm and Wall EACH 324.05
flange
Page 13
NO CODE DESCRIPTIONS UNIT RATE
31E X155E X.30.5) 40mm n.b. EACH 926
Page 14
NO CODE DESCRIPTIONS UNIT RATE
34A X170A X.33.1.1) For Internal Works - 15mm n.b. (1.23 MTR 126.35
kg/mtr)
34B X170B X.33.1.2) For Internal Works - 20mm n.b. (1.59 MTR 144.4
kg/mtr)
34C X170C X.33.1.3) For Internal Works - 25mm n.b. (2.46 MTR 204.15
kg/mtr)
34D X170D X.33.1.4) For Internal Works - 32mm n.b. (3.17 MTR 242.9
kg/mtr)
34E X170E X.33.1.5) For Internal Works - 40mm n.b. (3.65 MTR 290
kg/mtr)
34F X170F X.33.1.6) For Internal Works - 50mm n.b. (5.17 MTR 370.1
kg/mtr)
34G X170G X.33.1.7) For Internal Works - 65mm n.b. (6.63 MTR 410.95
kg/mtr)
34H X170H X.33.1.8) For Internal Works - 80mm n.b. (8.64 MTR 601.85
kg/mtr)
34I X170I X.33.1.9) For Internal Works - 100mm n.b. (12.4 MTR 780.95
kg/mtr)
Page 15
NO CODE DESCRIPTIONS UNIT RATE
34J X170J X.33.2.1) For external works - 15mm n.b. (1.23 MTR 109.55
kg/mtr)
34K X170K X.33.2.2) For external works - 20mm n.b. (1.59 MTR 121.35
kg/mtr)
34L X170L X.33.2.3) For external works - 25mm n.b. (2.46 MTR 176.35
kg/mtr)
34M X170M X.33.2.4) For external works - 32mm n.b. (3.17 MTR 205.75
kg/mtr)
34N X170N X.33.2.5) For external works - 40mm n.b. (3.65 MTR 238.1
kg/mtr)
34O X170O X.33.2.6) For external works - 50mm n.b. (5.17 MTR 308.8
kg/mtr)
34P X170P X.33.2.7) For external works - 65mm n.b. (6.63 MTR 325.85
kg/mtr)
34Q X170Q X.33.2.8) For external works - 80mm n.b. (8.64 MTR 491.45
kg/mtr)
34R X170R X.33.2.9) For external works - 100mm n.b. (12.4 MTR 651.35
kg/mtr)
34S X170S X.33.3.1) For Internal works labour charges MTR 53.65
excluding the cost of GI pipes but including cost
of GI specials - 15mm
34T X170T X.33.3.2) For Internal works labour charges MTR 60.4
excluding the cost of GI pipes but including cost
of GI specials - 20mm
34U X170U X.33.3.3) For Internal works labour charges MTR 69.2
excluding the cost of GI pipes but including cost
of GI specials - 25mm
34V X170V X.33.3.4) For Internal works labour charges MTR 79.8
excluding the cost of GI pipes but including cost
of GI specials - 32mm
34W X170W X.33.3.5) For Internal works labour charges MTR 96.55
excluding the cost of GI pipes but including cost
of GI specials - 40mm
34X X170X X.33.3.6) For Internal works labour charges MTR 122.2
excluding the cost of GI pipes but including cost
of GI specials - 50mm
Page 16
NO CODE DESCRIPTIONS UNIT RATE
34Y X170Y X.33.3.7) For Internal works labour charges MTR 143.6
excluding the cost of GI pipes but including cost
of GI specials - 65mm
34Z X170Z X.33.3.8) For Internal works labour charges MTR 168.95
excluding the cost of GI pipes but including cost
of GI specials - 80mm
34[ X1701 X.33.3.9) For Internal works labour charges MTR 208.35
excluding the cost of GI pipes but including cost
of GI specials - 100mm
34\ X1702 X.33.4.1) For External works labour charges MTR 37.2
excluding the cost of GI pipes but including cost
of GI specials - 15mm
34] X1703 X.33.4.2) For External works labour charges MTR 37.85
excluding the cost of GI pipes but including cost
of GI specials - 20mm
34^ X1704 X.33.4.3) For External works labour charges MTR 42.65
excluding the cost of GI pipes but including cost
of GI specials - 25mm
34_ X1705 X.33.4.4) For External works labour charges MTR 44.25
excluding the cost of GI pipes but including cost
of GI specials - 32mm
34` X1706 X.33.4.5) For External works labour charges MTR 48.65
excluding the cost of GI pipes but including cost
of GI specials - 40mm
34a X1707 X.33.4.6) For External works labour charges MTR 57.85
excluding the cost of GI pipes but including cost
of GI specials - 50mm
34b X1708 X.33.4.7) For External works labour charges MTR 63.5
excluding the cost of GI pipes but including cost
of GI specials - 65mm
34c X1709 X.33.4.8) For External works labour charges MTR 67.1
excluding the cost of GI pipes but including cost
of GI specials - 80mm
34d X1710 X.33.4.9) For External works labour charges MTR 78.95
excluding the cost of GI pipes but including cost
of GI specials - 100mm
Page 17
NO CODE DESCRIPTIONS UNIT RATE
35 X175 X.34) Providing, laying, jointing, fixing,
testing,commissioning threaded PVC pipes
schedule 40 conforming to ASTM-D-1785 with GI
specials, cutting the pipes to the required lengths,
threading, jointing the pipes
using teflon tape chasing the walls and floors,
making the holes, clamping to walls using the
wooden spacers or clamps and restoring the
same to the original conditions, necessary
excavation, testing, refilling etc. Complete all as
specified and directed and as per manufacturer's
specification.
35A X175A X.34.1.1) For Internal works - 15mm n.b. MTR 82.1
35B X175B X.34.1.2) For Internal works - 20mm n.b. MTR 98.95
35C X175C X.34.1.3) For Internal works - 25mm n.b. MTR 130.8
35D X175D X.34.1.4) For Internal works - 32mm n.b. MTR 162.7
35E X175E X.34.1.5) For Internal works - 40mm n.b. MTR 200.75
35F X175F X.34.1.6) For Internal works - 50mm n.b. MTR 261.8
35G X175G X.34.1.7) For Internal works - 65mm n.b. MTR 383.05
35H X175H X.34.1.8) For Internal works - 80mm n.b. MTR 480.9
35I X175I X.34.2.1) For External works - 15mm n.b. MTR 65.35
35J X175J X.34.2.2) For External works - 20mm n.b. MTR 75.75
35K X175K X.34.2.3) For External works - 25mm n.b. MTR 101.9
35L X175L X.34.2.4) For External works - 32mm n.b. MTR 122.75
35M X175M X.34.2.5) For External works - 40mm n.b. MTR 143
35N X175N X.34.2.6) For External works - 50mm n.b. MTR 188.8
35O X175O X.34.2.7) For External works - 65mm n.b. MTR 285.95
35P X175P X.34.2.8) For External works - 80mm n.b. MTR 343.8
35Q X175Q X.34.3.1) For Internal works labour charges MTR 49.85
excluding the cost of Threaded PVC pipes but
including cost of GI specials - 15mm
35R X175R X.34.3.2) For Internal works labour charges MTR 57.05
excluding the cost of Threaded PVC pipes but
including cost of GI specials - 20mm
Page 18
NO CODE DESCRIPTIONS UNIT RATE
35S X175S X.34.3.3) For Internal works labour charges MTR 64.55
excluding the cost of Threaded PVC pipes but
including cost of GI specials - 25mm
35T X175T X.34.3.4) For Internal works labour charges MTR 77.2
excluding the cost of Threaded PVC pipes but
including cost of GI specials - 32mm
35U X175U X.34.3.5) For Internal works labour charges MTR 97.85
excluding the cost of Threaded PVC pipes but
including cost of GI specials - 40mm
35V X175V X.34.3.6) For Internal works labour charges MTR 121.15
excluding the cost of Threaded PVC pipes but
including cost of GI specials - 50mm
35W X175W X.34.3.7) For Internal works labour charges MTR 160.45
excluding the cost of Threaded PVC pipes but
including cost of GI specials - 65mm
35X X175X X.34.3.8) For Internal works labour charges MTR 155.1
excluding the cost of Threaded PVC pipes but
including cost of GI specials - 80mm
35Y X175Y X.34.4.1) For External works labour charges MTR 33.1
excluding the cost of Threaded PVC pipes but
including cost of GI specials - 15mm
35Z X175Z X.34.4.2) For External works labour charges MTR 33.55
excluding the cost of Threaded PVC pipes but
including cost of GI specials - 20mm
35[ X1751 X.34.4.3) For External works labour charges MTR 37.05
excluding the cost of Threaded PVC pipes but
including cost of GI specials - 25mm
35\ X1752 X.34.4.4) For External works labour charges MTR 47.55
excluding the cost of Threaded PVC pipes but
including cost of GI specials - 32mm
35] X1753 X.34.4.5) For External works labour charges MTR 41.7
excluding the cost of Threaded PVC pipes but
including cost of GI specials - 40mm
35^ X1754 X.34.4.6) For External works labour charges MTR 49.55
excluding the cost of Threaded PVC pipes but
including cost of GI specials - 50mm
35_ X1755 X.34.4.7) For External works labour charges MTR 56.25
excluding the cost of Threaded PVC pipes but
including cost of GI specials - 65mm
Page 19
NO CODE DESCRIPTIONS UNIT RATE
35` X1756 X.34.4.8) For External works labour charges MTR 58.65
excluding the cost of Threaded PVC pipes but
including cost of GI specials - 80mm
37 X185A X.36) Providing and fixing UPVC floor trap with EACH 256.55
75mm dia outlet "Supreme" or other equivalent
approved make, including connection with PVC
soil / waste pipe, necessary 150mm thick CC
1:2:4 for embedding the trap including providing
and fixing top rail and strainer on top of the trap
etc. complete all as specified and directed.
Page 20
NO CODE DESCRIPTIONS UNIT RATE
38B X190B X.37.2) 110mm dia (Min.wall thickness3.2mm) MTR 368.7
Page 21
NO CODE DESCRIPTIONS UNIT RATE
43 X215A X.42) Providing and Fixing best Indian make EACH 4383.95
kitchen sink with Drain board comprising of : A)
Best Indian make stainless steel kitchen sink of
approved make of overall size 915X457X200mm,
Bowl size 428X357X200mm, 1mm thick
supported on a pair of painted CI brackets
conforming to IS775. B) One 40mm heavy quality
CP brass waste coupling . C) One 32mm PVC
waste pipe bent to shape length not exceeding
1m. To discharge in to the floor trap through the
GI elbow. D) 40mm GI medium class pipe
250mm long connecting elbow to floor trap
Complete all as specified with approved fittings.
Page 22
NO CODE DESCRIPTIONS UNIT RATE
44 X220A X.43) Providing and Fixing best Indian make EACH 3768.3
kitchen sink without Drain board comprising of :
A) Best Indian make stainless steel kitchen sink of
approved make of overall size 610 X 457 X
200mm, Bowl size 428 X 375 X 200mm, 1mm
thickness supported on painted CI brackets
conforming to IS:775. B) One 40mm heavy
quality CP brass waste coupling C) One 32mm
PVC waste pipe bent to shape, length not
exceeding 1m. To discharge in to the floor trap
through 40mm GI elbow, 40mm dia 250mm long
GI medium class pipe connecting to floor trap.
Complete all as specified with approved fittings.
Page 23
NO CODE DESCRIPTIONS UNIT RATE
Y.EXTERNAL WATER SUPPLY
47A Y015A Y.03.1) 80mm dia( with 4 bolts & nuts 16mm dia EACH 94.5
60mm long)
Page 24
NO CODE DESCRIPTIONS UNIT RATE
Page 25
NO CODE DESCRIPTIONS UNIT RATE
47B Y015B Y.03.2) 100mm dia( with 8 bolts & nuts 16mm EACH 155.1
dia 60mm long)
47C Y015C Y.03.3) 150mm dia( with 8 bolts & nuts 20mm EACH 280.95
dia 65mm long)
47D Y015D Y.03.4) 200mm dia( with 8 bolts & nuts 20mm EACH 296.05
dia 70mm long)
47E Y015E Y.03.5) 250mm dia(with 12 bolts & nuts 20mm EACH 417.5
dia 75mm long)
47F Y015F Y.03.6) 300mm dia(with 12 bolts & nuts 20mm EACH 446.05
dia 75mm long)
Page 26
NO CODE DESCRIPTIONS UNIT RATE
49D Y025D Y.05.4) 150mm dia EACH 79.3
Page 27
NO CODE DESCRIPTIONS UNIT RATE
50S Y030S Y.06.3.3) 10 Kg/Sq.cm and 32mm OD MTR 65.1
Page 28
NO CODE DESCRIPTIONS UNIT RATE
50T Y030T Y.06.3.4) 10 Kg/Sq.cm and 40mm OD MTR 88.45
52A Y040A Y.08.1.1) Single ball air valve and 15mm suitable EACH 39.4
up to 100mm main
52B Y040B Y.08.1.2) Single ball air valve and 20mm suitable EACH 48.1
up to 100mm main
52C Y040C Y.08.1.3) Single ball air valve and 25mm suitable EACH 65.7
up to 100mm main
52D Y040D Y.08.1.4) Double ball air valve and 40mm EACH 80.75
suitable up to 100mm main
Page 29
NO CODE DESCRIPTIONS UNIT RATE
52E Y040E Y.08.1.5) Double ball air valve and 50mm EACH 98.65
suitable up to 200mm main
Page 30
NO CODE DESCRIPTIONS UNIT RATE
52F Y040F Y.08.1.6) Double ball air valve and 80mm EACH 120.15
suitable up to 350mm main
53 Y045A Y.09) Fixing of fire hydrant landing valve type EACH 482.25
pipe to CI main including making 4 numbers of
80mm dia flanged joints for fixing the hydrant
landing valve, CI flanged bends and CI stand pipe
to the CI main, painting, testing etc. Complete all
as specified and directed. (Landing valve type
fire hydrant, 80mm dia CI flanged pipe and bends
will be supplied free of cost at departmental
stores.) RCC anchor block shall be provided and
measured separately elsewhere as an Item. (Ref.
Fig.No.CED:PH 5.7 of PH Engg. Works)
Page 31
NO CODE DESCRIPTIONS UNIT RATE
conforming to IS 1726 with locking arrangement
fixing the frame in RCC1:2:4 including cost of
necesary steel reinforcement, fabricating, form
work, curing, etc, complete all as specified and
directed. Note: CC 1:2:4 in the above Item is by
using 20mm graded granite aggregate obtained
from approved quarry.
Page 32
NO CODE DESCRIPTIONS UNIT RATE
58 Z005A Z.01) Providing and Fixing in position best quality EACH 1585.3
salt glazed stoneware gully trap of size 100mm
square with 100mm outlet; conforming to IS:651
embedded in plain cement concrete 1:4:8 (20mm
Metal), providing and fixing 100mm square CI
grating on top of the trap, all the above encased
in a chamber of 300X300mm built with 115mm
thick brick masonry using first class country bricks
in CM 1:3, over a bed of CC 1:4:8 using 40mm
size metal 100mm thick, plastering with CM 1:3,
13mm thick inside, outside, exposed top surfaces
Page 33
NO CODE DESCRIPTIONS UNIT RATE
60 Z015 Z.03) Construction of Inspection chamber of
internal clear dimensions as mentioned below in
230mm thick brick masonry using first class
country brick walls in CM 1:3 over a bed of
150mm thick 1:2:4(20mm metal) cement
concrete, plastering with CM 1:2, 12mm thick on
internal, external, top surfaces and internal and
exposed top surfaces finished smooth with a
floating coat of neat cement, Plain cement
concrete 1:2:4 for benching, channeling,
providing and fixing light single seal CI frame and
cover as mentioned below
60A Z015A Z.03.1) 450X450X450mm with frame and cover EACH 3653.8
of size 450X450mm weighing not less than 25Kg.
60B Z015B Z.03.2) 600X600X600mm with frame and cover EACH 5405.3
of size 610X450mm weighing not less than 38Kg.
60C Z015C Z.03.3) 600X600X750mm with frame and cover EACH 5812.35
of size 610X450mm weighing not less than 38Kg.
Page 34
NO CODE DESCRIPTIONS UNIT RATE
fixing pre-cast RCC M15 frame and cover as
mentioned below including cost of necessary
steel reinforcement as per drawing, encasing
sewers connection to chamber in PCC 1:2:4
Complete all as specified and directed. (Ref.
Fig.No.CED:PH8.6 of PH Engg. Specification)
Note: CC 1:2:4 in the above Item is by using
20mm graded granite aggregate obtained from
approved quarry
Page 35
NO CODE DESCRIPTIONS UNIT RATE
Page 36
NO CODE DESCRIPTIONS UNIT RATE
CI steps with 3-coats of anticorrosive, black
bitumastic painting, encasing of sewer
connections to manholes with PCC 1:2:4 etc.
Complete all as specified and directed for initial
depth of 0.75m (Ref. Fig.No.CED:PH 8.7 of PH
Engg. Specification) Note: CC 1:2:4 in the above
Item is by using 20mm graded granite aggregate
obtained from approved quarry.
Page 37
NO CODE DESCRIPTIONS UNIT RATE
cover of size 600X600mm including the cost of
steel reinforcement as per drawing and CI steps
with 3-coats of anticorrosive, black bitumastic
paint, encasing of sewers connections to manhole
with PCC 1:2:4 etc. Complete all as specified and
directed for initial depth of 1.0 mtr (Ref.
Fig.No.CED:PH8.9 of PH Engg. Specification)
Note: CC 1:2:4 in the above Item is by using
20mm graded granite aggregate obtained from
approved quarry.
68A Z055A Z.11.1) CI frame and cover 500mm dia weighing EACH 13276.8
not less than 52Kgs conforming to IS:1726
68B Z055B Z.11.2) Medium duty CI frame and cover 500mm EACH 16176.5
dia weighing not less than 116Kgs conforming to
IS:1726
Page 38
NO CODE DESCRIPTIONS UNIT RATE
Page 39
NO CODE DESCRIPTIONS UNIT RATE
two layers of bamboo matting with surface treated
with bitumen and joints staggered on filter bed all
as directed and specified. (E) Supply and
Laying of 1 layers of 1000gauge (250 microns)
thick LDPE film conforming to IS:2508-1977 over
the bamboo matting all as specified and directed.
Page 40