Formulas
For further
Pin [MW ] kJ
Formulas refer Heat Rate: Unit :
to your Formula Pout [MW ] x 277.8 10 − 6 kWh
Book!
Losses simplified
to 0%, in Reality Energy in fuel
the individual
Losses lay at
about 0.5% each
Losses in HRSG
0% Gas turbine
Losses
0%
Steam turbine
Stack
Losses
0%
Condenser CSXA403479.cdr
Exercise 1
• Gas turbine type GT26 natural gas fired, operated on base load / maximal
load.
• Fuel gas lower heating value (LHV) 43.094 MJ/kg.
• Mass flow fuel gas 15.81 kg/sec.
• Gross power output GT 262 MW.
• Gross power output ST 138.8 MW.
• Cooling water for condenser Tin 31.4 °C, Tout 42.5 °C, mass flow 4860 kg/sec.
• Exhaust gas temperature after turbine (TAT LPT) 640 °C, after stack 102 °C.
• Exhaust gas mass flow 562 kg/sec.
Calculate
Exercise 1, Solution
Gross efficiency
Energy ratio
Exercise 2
• Gas turbine type GT26 natural gas fired, operated at about 50 % of base load.
• Fuel gas lower heating value (LHV) 43.094 MJ/kg.
• Mass flow fuel gas 10.9 kg/sec.
• Gross power output GT 140 MW.
• Gross power output ST 73.8 MW.
• Cooling water for condenser Tin 31.6 °C, Tout 41.55 °C,
mass flow 4860 kg/sec.
• Exhaust gas temperature after turbine (TAT LPT) 635 °C, after stack 125 °C.
• Exhaust gas mass flow 75 % of 562 kg/sec.
Calculate
Exercise 2, Solution
Gross efficiency
Energy ratio
Gross efficiency ST
Exercise 3
• Gas turbine type GT24 fuel oil fired, operated at base load.
• Fuel oil LHV 42.00 MJ/kg.
• Energy input by fuel oil 514.3 MW.
• Gross power output GT 177 MW.
• Gross power output ST 92.5 MW.
• Cooling water for condenser Tin 30.5 °C, Tout 42.9 °C, mass flow 3550 kg/sec.
• Exhaust gas temperature after turbine (TAT LPT) 640 °C, after stack 155 °C.
• Exhaust gas mass flow 391 kg/sec.
Calculate
Exercise 3, Solution
Energy ratio
Solution Key
Exercise 1
Gross efficiency
Energy ratio
Cooling water P =m
&
water ⋅ c ⋅ ∆T
k/ g/ J K/
= 4860 ⋅ 4187 (42.5 − 31.4)
sec k/ g/ K/
= 225.66 ⋅ 106 W = 225.7 MW
Exhaust gas P =m
&
air
⋅ cp ⋅ ∆T
(stack)
∆T = diff. temp stack exit to ambient temp.
k/ g/ J K/
= 562 ⋅ 1007 (102 − 19)
sec k/ g/ K/
= 46.97 ⋅ 106 W = 47.0 MW
Energy input P=m
& ⋅ LHV = 15.81 ⋅ 43.094 ⋅ 106
gas
= 681.32 ⋅ 106 W = 681.3 MW
262 ⋅ 106
η gross GT = = 0.377 equal 37.7%
15.81 ⋅ 43.094 ⋅ 106
Exercise 2
Gross efficiency
Energy ratio
Cooling water P =m
&
water ⋅ c ⋅ ∆T
= 4860 ⋅ 4187 ⋅ (41.55 − 31.6) = 202.5 ⋅ 106 W
Exhaust gas P =m
&
air ⋅ cp ⋅ ∆T
(stack)
= 0.75 ⋅ 562 ⋅ 1007 ⋅ (125 − 19)
= 45.0 ⋅ 106 W
Energy input P=m
& ⋅ LHV = 10.90 ⋅ 43.094 ⋅ 106 = 469.7 ⋅ 106 W
gas
Gross efficiency ST
Exercise 3
514.3 ⋅ 106 J/ kg
m
& = = 12.25 kg
42.0 ⋅ 106 sec J/ sec
(177 + 92.5) ⋅ 106
η gross = = 0.524 equal 52.4%
514.3 ⋅ 106
Energy ratio
6
Cooling water P water = 3550 ⋅ 4187 (42.9 − 30.5) = 184.3 ⋅ 10 W
6
Exhaust gas P air = 391 ⋅ 1007 (155 − 19) = 53.55 ⋅ 10 W
(stack)
177 ⋅ 106
η gross GT = = 0.344 = 34.4%
514.3 ⋅ 106
514.3 ⋅ 106
HR =
177 ⋅ 106 ⋅ 277.8 ⋅ 10 −6
kJ
= 10'456
kWh