You are on page 1of 7

ZND594_A-AMT-Td-0001-Rev.

FAST PLANETS Co Ltd.,


ENGINEERING DEPARTMENT
P.0. BOX : 34620
RIYADH - 11478

Project: 3G 2010

COMPARISON OF ANTENNA LOADING


FOR
36.0m TEP 6 TOWER
(BABTAIN)

Site No.: ZND594-A


EXISTING + PROPOSED LOADING CONDITION
FOR
BASIC WIND SPEED at 39 m/s

&
BASIC WIND SPEED at 35 m/s
ZND594_A-AMT-Td-0001 Rev. A

TABLE OF CONTENTS

TITLE PAGE No.

COVER PAGE 1

TABLE OF CONTENTS 2

SCOPE 3

ORIGINAL DESIGNED LOADS 3

EXISTING ANTENNA LOADS 3-4

CONCLUSION 4

Analyzed by: Checked by: Approved by:

________________ ________________ ____________________


J.B.Vasquez R.V.Corpuz M.A. Aqeel
Telecom Engr. Structural Engr. Projects Manager

Page 2
ZND594_A-AMT-Td-0001 Rev. A

SCOPE:

The existing tower at this site is a 36.0m TEP 6 tower. The scope of study is,
Comparison of the existing Antennas with the original designed Antennas of the tower.

Original Designed Antennas : (Basic wind speed @ 39m/s)

Basic Wind Base


Exposure Load Antenna Wind Load Moment

Coefficient Fa (kn) FaxGhxKzxn (KN-M)


Design Qty. 1.0<Kz<2.5
Loads Size Dept (no) Ht (m) 8      
GSM 2.00 x GSM 18 35.00 1.430 0.886 23.031 806.114
Antenna 0.30m
s (Initial)
Standard 1.20m MW 2 33.00 1.406 0.427 1.212 40.021
M/W dia
Ant.
  846.135

Existing & Proposed Antennas on the tower : (Basic wind speed @ 39m/s)

                   
S.No Design Size Dept Qty, n Elevation Exposure Basic Antenna Base
Loads Coefficient Wind Wind Load moment
load
          (m) 1.0< Fa (kn) Fa*Gh*Kz* (kn-m)
kz<2.58 n
                   
Existing antenna loading
1 LR 2.0M Long GSM 1 36.00 1.441 0.094 0.136 4.926

2 GSM 2.0x0.30m GSM 9 35.00 1.430 0.886 11.515 403.057


antenna
3 3G 1.80x0.30m GSM 3 35.00 1.430 0.668 2.894 101.295
antenna
4 GSM 1.80x0.30m GSM 3 35.00 1.430 0.664 2.876 100.688
antenna
5 Vacant - GSM 6 35.00 1.430 0.194 1.681 58.836
Pole
6 Vacant - GSM 2 32.00 1.394 0.194 0.546 17.477
Pole
7 HP 0.30dia MW 1 32.00 1.394 0.102 0.143 4.594
Antenna
8 Vacant - GSM 1 30.00 1.368 0.194 0.268 8.043
Pole

Page 3
ZND594_A-AMT-Td-0001 Rev. A

9 HP 0.30dia MW 1 30.00 1.368 0.102 0.140 4.228


Antenna
10 GSM 2.0x0.30m GSM 2 30.00 1.368 0.886 2.448 73.465
antenna
11 GSM 2.0x0.30m GSM 2 29.50 1.362 0.886 2.437 71.894
antenna
12 Vacant - GSM 1 29.50 1.362 0.194 0.266 7.871
Pole
13 HP 0.30dia MW 2 27.00 1.328 0.102 0.273 7.386
Antenna
14 HP 0.20dia MW 2 26.00 1.313 0.042 0.111 2.897
Antenna
15 HP 0.30dia MW 1 23.50 1.276 0.102 0.131 3.089
Antenna
16 Vacant - GSM 1 18.00 1.182 0.194 0.231 4.170
Pole
TOTAL 873.921

Proposed Antenna Loading


1 HP 0.3mdia MW 1 34.00 1.418 0.102 0.146 4.967
Antenna
TOTAL 4.967

GRAND 878.88
TOTAL

Design Antennas > Proposed & Existing Antennas


846.135 < 878.88 therefore Not OK!

Conclusion:

By comparing the existing & proposed antennas with the Original Designed antennas as shown in
the above tables, it is concluded that the combined load due to existing & proposed antennas is
greater than the Original Designed antenna loads under a windspeed of 39 m/s. Therefore, the
existing tower cannot safely support the existing & proposed antenna loading. A subsequent tower
comparison under a windspeed of 35 m/s is hereby attached for reference.

Existing & Proposed Antennas on the tower : (Basic wind speed @ 35m/s)

Page 4
ZND594_A-AMT-Td-0001 Rev. A

                   

Page 5
ZND594_A-AMT-Td-0001 Rev. A

S.No Design Size Dept Qty, n Elevation Exposure Basic Antenna Base
Loads Coefficient Wind Wind Load moment
load
          (m) 1.0< Fa (kn) Fa*Gh*Kz* (kn-m)
kz<2.58 n
                   
Existing antenna loading
1 LR 2.0M Long GSM 1 36.00 1.441 0.075 0.110 3.983

2 GSM 2.0x0.30m GSM 9 35.00 1.430 0.713 9.267 324.356


antenna
3 3G 1.80x0.30m GSM 3 35.00 1.430 0.537 2.326 81.430
antenna
4 GSM 1.80x0.30m GSM 3 35.00 1.430 0.534 2.313 80.975
antenna
5 Vacant - GSM 6 35.00 1.430 0.156 1.351 47.311
Pole
6 Vacant - GSM 2 32.00 1.394 0.156 0.439 14.054
Pole
7 HP 0.30dia MW 1 32.00 1.394 0.082 0.115 3.693
Antenna
8 Vacant - GSM 1 30.00 1.368 0.156 0.215 6.467
Pole
9 HP 0.30dia MW 1 30.00 1.368 0.082 0.113 3.399
Antenna
10 GSM 2.0x0.30m GSM 2 30.00 1.368 0.713 1.970 59.120
antenna
11 GSM 2.0x0.30m GSM 2 29.50 1.362 0.713 1.961 57.856
antenna
12 Vacant - GSM 1 29.50 1.362 0.156 0.214 6.329
Pole
13 HP 0.30dia MW 2 27.00 1.328 0.082 0.219 5.937
Antenna
14 HP 0.20dia MW 2 26.00 1.313 0.033 0.087 2.276
Antenna
15 HP 0.30dia MW 1 23.50 1.276 0.082 0.105 32.483
Antenna
16 Vacant - GSM 1 18.00 1.182 0.156 0.186 3.353
Pole
TOTAL 703.029

Proposed Antenna Loading


1 HP 0.3mdia MW 1 34.00 1.418 0.082 0.117 3.993
Antenna
TOTAL 3.993

GRAND 707.022
TOTAL

Page 6
ZND594_A-AMT-Td-0001 Rev. A

Design Antennas > Proposed & Existing Antennas


846.135 > 707.022 therefore OK!

Conclusion:

By comparing the existing & proposed antennas with the Original Designed antennas as shown in
the above tables, it is concluded that the combined load due to existing & proposed antennas is less
than the Original Designed antenna loads under a windspeed of 35 m/s. Therefore, the existing
tower can safely support the existing & proposed antenna loading at a wind speed of 35 m/s.