epro • System III MBB Waterproofing / Gas Barrier Patent Pending

Excellent Strength and Durability • Exceptional Chemical Resistance • Seamless System • Fully Bonded to Slab • Redundant Protection

System Description
System III MBB is a field installed composite
waterproofing and gas vapor barrier that is
Ecoshield-PB
comprised of a water-based Polymer Modified
Asphalt (PMA) membrane and Bentonite sheet Ecoline-S
sandwiched between two HDPE and Polypropylene Ecoshield-P
fabric laminate films which provides the durability
and chemical resistance of HDPE with the Soil

constructability and installation efficiencies of a


PMA and the self sealing ability of Bentonite.

System Components

Ecoshield-P (Base Course) – An HDPE film


laminated with a nonwoven polypropylene fabric Excellent Strength and Chemical Resistance – The
geo-membrane. result of the unique field installed composite design
Ecoline-S (Middle Course) – A spray or fluid with HDPE Films.
applied, water based Polymer Modified Asphalt
Self Sealing – The bentonite layer seals at any
membrane. penetration of the barrier.
Ecoshield-PB - A geocomposite membrane
comprised of bentonite granules laminated to an Seamless System – The fluid applied component
HDPE and polypropylene fabric sheet membrane. makes the transition details to field barrier a
monolithic installation.
Additional Information
Fully Bonded to Slab – The geo-textile surface of the
barrier mechanically interlocks with the concrete
Specifications – Reference “Specification Beneath slab to form a permanent bond between the
Slab Moisture Barrier” barrier and slab.
Detail Drawings – Reference all “MB” labeled details
Installation Guidelines – Reference “Moisture Barrier Redundant Protection – Multiple waterproofing and
Installation” and “Repair Procedures – Moisture gas vapor barriers as well as protection courses.
Barrier” OF DIFFE
LD RE
OR
Product Information – Reference “Ecoline-S”, W
N
CE
A

“Ecoline-R”, “Ecoshield-P”, “Beneath Slab Gas Vapor


Barrier” product brochures.
S
FO

ON
R

TI

W a te r p r oo f i n g Sys tems EA I
R

LW ND
ORLD CO

800-882-1896 • www.eproserv.com
rev. sys3-mbb_120910
epro • System III MBB - Moisture / Gas Barrier
Epro Below Slab Water / Gas Barrier Composite System Testing
Composition - Ecoshield-P / Ecoline-S / Ecoshield-PB

Tensile Strength* ......................... ASTM D-412 ..... 662 psi Chemical Permeation** .... ASTM F-739 Perm Rate Perm Rate
Elongation* .................................. ASTM D-412 ..... 45% Ug/cm2 ml/day
Adhesion to Concrete*** .............. ASTM C-836 .... 27 lbf/in Chlorinated Solvent
Puncture Resistance .................... ASTM E-154-99..373.18 lbs Perchloroethylene ................................... 69.4 .......... 0.0008
Hydrostatic Pressure ................... ASTM D-5385 ... 369.5 ft. Trichloroethylene ........ ............................ 89.8 .......... 0.0012
Aromatic Hydrocarbon
Soil Burial* ................................... ASTM D-4068 Benzene .................... ............................ 59.3 .......... 0.0013
Weight change ..................... See Note 1 ........ 1.2% ......... passed
Tensile Strength ................... See Note 1 ........ 9.89% ....... passed Chemical Resistance** ...... ASTM D-543 Net change
Elongation ............................ See Note 1 ........ 2.2% ......... passed Chlorinated Solvents .. ASTM D-882 Mod. (Less 10% pass)
Perchloroethylene
Heat Aging* ................................. ASTM D-4068 Weight ........................ ............................. 4.1%
Tensile Strength .................. See Note 1 ....... 8.6% ......... passed Tensile Strength ......... ............................. 6.5%
Elongation .......................... See Note 1 ....... 8.9% ......... passed Tricholorethylene
Weight ........................ ............................. 5.4%
Environmental Stress Cracking* .. ASTM D-1693 Tensile Strength ......... ............................. 6.0%
Failure ................................ See Note 2 ........ 620 hrs. .... passed
Aromatic Hydrocarbon
Oil Resistance* .......................... ASTM D-543 & Benzene
ASTM D-412 Weight ........................ ............................. 4.1%
Weight change ............................ See Note 1 ....... 7.6% ......... passed Tensile Strength ......... ............................. 4.4%
Tensile Strength ................. See Note 1 ....... 1.1% ......... passed
Elongation .......................... See Note 1 ....... 4.4% ......... passed Gases
Hydrogen Sulfide
Methane Transmission* .............. ASTM D-1434 Weight ........................ ............................. 0.6%
See Note 3 ....... 3.70xE-15.. passed Tensile Strength ......... ............................. 0.8%

* Tests performed by SGS / US Testing W


OR
LD
OF DIFFE
RE
N
CE
A

** Tests performed by TRI Environmental


*** Tests performed by Momentum Technologies
S
FO

ON
R

Wa te r p r oo f i n g Sys tems
TI

EA I
R

LW ND
O RL D C O
Note 1: LA requires less than 10%
Note 2: LA requires over 500 hrs. 800-882-1896 • www.eproserv.com
Note 3: LA requires less than 3 ml per day

rev.sys3mbb_120910