You are on page 1of 2

epro • System III RDB Roof / Deck Waterproofing

Seamless System • Extremely Strong and Durable • Excellent Adhesion • Exception Chemical Resistance • Redundant Protection

System Description
Ecodrain-S6000
System III RDB is a field installed composite
waterproofing system comprised of a water-based Ecoshield-EB

polymer modified asphalt (PMA) membrane with Ecoline-S


polyester fabric reinforcement laminated to an with reinforcement
fabric
HDPE and bentonite geomembrane that is
Concrete
protected by a HDPE or polypropylene drainage
composite.

System Components

Ecoline-S (Interior Course): A spray fluid applied, Features & Benefits


water-based polymer modified asphalt (PMA)
membrane. Seamless System - The fluid applied membrane
Ecoshield-EB (Middle Course): An HDPE film and component of composite system ensure a monolithic
barrier even at the transitions.
bentonite laminate.
Ecodrain-S (Exterior Course): A polypropylene Excellent Strength and Chemical Resistance – The
core and non-woven polypropylene fabric drainage polyester fabric reinforcement increases the strength
composite. of the system while the HDPE or polypropylene fabric
provides a tough protective layer.
Additional Information
Excellent Adhesion - The polymeric makeup of the
waterproofing membrane provides excellent
Specifications - See Concrete Deck bonding to substrate even in damp conditions.
Detail Drawing - Reference all CD and WP labeled
drawings. Self Sealing – The bentonite layer seals at any
Installation Guidelines - Reference 1. penetration of the barrier.
Waterproofing Membrane Installation (Horizontal Redundancy - Provided by multiple waterproofing
Reinforced) 2. Waterproofing Membrane membranes, protection courses and drainage.
Installation (Vertical Reinforced) 3. Ecoshield
Installation 4. Ecodrain Installation. OR
LD
OF DIFFE
RE
N
W
Insert drawings M-1 and N-1a on back
CE
A

S
FO

ON
R

TI

Wa te r p r oo f i n g Sys tems EA I
R

LW ND
ORLD CO

800-882-1896 • www.eproserv.com
rev.sys3_rdb120610
Drawing N-1a

1. Concrete
2. EcolineÐS / EcolineÐR (60 Mils)
3. Polyester Reinforcement Fabric
4. EcolineÐS / EcolineÐR (60 Mils)
5. EcoshieldÐEB
6. EcodrainÐE or EcodrainÐS
7. Overlay Material

epro • System III RDB - Roof / Deck Waterproofing


Epro Between Slab Waterproofing System Testing
Water-based polymer modified asphalt (PMA) membrane with polyester fabric reinforcement laminated to either a
polyolefin or HDPE geomembrane. ( Ecoshield-E / Ecoline-S / Ecodrain-S )

Tensile Strength* ......................... ASTM D-412 .... 662 psi Chemical Permeation** .... ASTM F-739 Perm Rate Perm Rate
Elongation* .................................. ASTM D-412 .... 45% Ug/cm2 ml/day
Adhesion to Concrete*** .............. ASTM C-836 .... 11 lbf/in Chlorinated Solvent
Adhesion to Film .......................... ASTM C-836 .... 28.363 lbf/in Perchloroethylene ................................... 69.4 .......... 0.0008
Puncture Resistance ................... ASTM D-1709 .. 123 lb. Trichloroethylene .................................... 89.8 .......... 0.0012
Aromatic Hydrocarbon
Soil Burial* ................................... ASTM D-4068 Benzene .................... ............................ 59.3 .......... 0.0013
Weight change ..................... See Note 1 ...... 1.2% .......... passed
Tensile Strength ................... See Note 1 ...... 9.89% ........ passed Chemical Resistance** ...... ASTM D-543 Net change
Elongation ............................ See Note 1 ...... 2.2% .......... passed
Chlorinated Solvents ......... ASTM D-882 Mod. (Less 10% pass)
Heat Aging* ................................. ASTM D-4068 Perchloroethylene
Tensile Strength .................. See Note 1 ...... 8.6% .......... passed Weight ........................ ............................ 4.1%
Elongation .......................... See Note 1 ...... 8.9% .......... passed Tensile Strength ......... ............................ 6.5%
Tricholorethylene
Environmental Stress Cracking* .. ASTM D-1693 Weight ........................ ............................ 5.4%
Failure ................................ See Note 2 ...... 620 hrs. ..... passed Tensile Strength ......... ............................ 6.0%

Oil Resistance* .......................... ASTM D-543 & Aromatic Hydrocarbon


ASTM D-412 Benzene
Weight change ..................... See Note 1 ...... 7.6% .......... passed Weight ........................ ............................. 4.1%
Tensile Strength ................. See Note 1 ...... 1.1% .......... passed Tensile Strength ......... ............................ 4.4%
Elongation .......................... See Note 1 ...... 4.4% .......... passed
Gases
Methane Transmission* .............. ASTM D-1434 Hydrogen Sulfide
See Note 3 ...... 3.70xE-15... passed Weight ........................ ............................. 0.6%
Tensile Strength ......... ............................. 0.8%
* Tests performed by SGS / US Testing
** Tests performed by TRI Environmental
*** Tests performed by Momentum Technologies

Note 1: LA requires less than 10%


Note 2: LA requires over 500 hrs.
Note 3: LA requires less than 3 ml per day

rev.sys3rdb_120710