You are on page 1of 2

Electronics

Coaxial Cable

RG 8/U Type
Product Construction: Shield: Packaging:
• Tinned or bare copper braid • Please contact Customer Service for
Conductors: packaging and color options
• Flexfoil® shield
• Copper per ASTM B-3
Jacket: Applications:
Insulation/Core: • Suitable for RF signal transmission
• Premium PVC compound
• Solid and cellular polyethylene designs • Broadcast
• See Coax Connector Cross Reference,
pages 192-199

AWG INSULATION SHIELD NOMINAL NOMINAL VELOCITY OF NOMINAL NOMINAL


CATALOG SIZE MATERIAL COVERAGE O.D. CAPACITANCE PROPAGATION, IMPEDANCE, ATTENUATION
NUMBER NOM. DCR INCHES mm NOM SHLD DCR INCHES mm pF/ft pF/m % Ω MHz dB/100'

C1108A 16 Ga. 95% Bare 25.30 83.01 80 50 1 0.26


RG 8/U Mini Type (19/28) Foam PE Copper Braid Black PVC 10 0.98
UL CL2, CM Bare 3.3 Ω/Mft. 50 2.30
100 3.30
CSA CMG Copper 0.155 3.94 0.242 6.15 200 4.90
1354 4.2 Ω/Mft. 500 8.50
1000 14.30

C1154 13 Ga. 95% Bare 29.50 96.79 66 52 1 0.16


RG 8/U Type (7/21) Solid PE Copper Braid Black PVC 10 0.56
JAN-C-17A TYPE Bare 1.2 Ω/Mft. 50 1.30
0.285 7.24 0.405 10.29 100 1.90
1354 Copper 200 2.80
1.9 Ω/Mft. 500 4.70
1000 7.40

C1198 11 Ga.
Foam PE
95% Bare
Black PVC
26.00 85.31 78 50 1 0.17
RG 8/U Type (19/24) Copper Braid 10 0.57
1354 Bare 1.1 Ω/Mft. 50 1.20
0.285 7.24 0.405 10.29 100 1.80
Copper 200 2.70
1.9 Ω/Mft. 500 4.70
1000 7.10
C1180 9½ Ga.
Semi-Solid PE
100% Flexfoil®
Black PVC
24.60 80.71 84 50 1 0.13
RG 8/U Type Solid Bare Bonded 10 0.40
Copper +88% 50 0.90
0.285 7.24 0.405 10.29 100 1.30
0.90 Ω/Mft. Tinned Copper 200 1.80
Braid 500 3.00
1.8 Ω/Mft. 1000 4.50

94
Coaxial Cable Electronics

RG 8/U Type Thicknet/Trunk Cable


50 Ohm IEEE 802.3 and ISO/IEC 8802.3 10 Base 5 LAN and Computer Cables
Product Construction: Jacket: Applications:
• Premium PVC compound • LAN & data transmission computer cables
Conductors: • Premium fluoropolymer compound • Thicknet/trunk cable – IEEE 802.3
• Copper per ASTM B-3 and ISO/IEC 8802.3 10 base 5 LAN
Packaging:
Insulation/Core: computer cables
• Please contact Customer Service for • See Coax Connector Cross Reference,
• Foam polyethylene (PE) design packaging and color options pages 192-199
• Foam fluoropolymer (FEP) design
Shield:
• Tinned copper braid
• Flexfoil® shield

AWG INSULATION SHIELD NOMINAL NOMINAL VELOCITY OF NOMINAL NOMINAL


CATALOG SIZE MATERIAL COVERAGE O.D. CAPACITANCE PROPAGATION, IMPEDANCE, ATTENUATION
NUMBER NOM. DCR INCHES mm NOM SHLD DCR INCHES mm pF/ft pF/m % Ω MHz dB/100'

397001 12 Ga. Quad Shield Yellow 26.00 85.30 78 50 1 0.17


RG 8/U Type Solid Bare Foam PE Dual Flexfoil® Flame-Retardant 5 0.37
THICKNET Copper 94% Tinned PVC 10 0.53
1.42 Ω/Mft. 50 1.20
DEC 17-000451-00 Copper Braid
100 1.73
UL CM c(UL) 0.245 6.22 + Dual Flexfoil® 0.405 10.29
200 2.50
94% Tinned 400 3.64
Copper Braid 700 4.97
1.52 Ω/Mft. 900 5.74
1000 6.10
497001 12 Ga. Quad Shield Orange 25.00 82.00 84 50 1 0.16
Fluoropolymer 5 0.35
RG 8/U Type Solid Bare Dual Flexfoil® PVDF
THICKNET Copper 94% Tinned 10 0.51
0.245 6.22 0.375 9.53 50 1.19
DEC 17-000324-00 1.42 Ω/Mft. Copper Braid
100 1.75
UL CMP c(UL) + Dual Flexfoil® 200 2.61
94% Tinned 400 3.97
Copper Braid 700 5.65
1.52 Ω/Mft. 900 6.67
1000 7.14

95