You are on page 1of 1

Website: www.nulec.com.

au Nu-Lec Reclosers
Windows Switchgear Operating System
packed with new features
Nu-Lec Industries' latest version of incorporates a Curve Editor and a Curve notifications.
Windows Switchgear Operating System Viewer. With the Curve Editor users can Callouts are
(WSOS) includes six new features. create point-by-point a whole library of sent out via
Designed to offer increased flexibility in protection curves, and upload up to five e-mail,
communications, password security, curves to a recloser. Each curve can have pager, SMS
control and protection. up to 30 (I, t) points entered in an Excel and
Three basic features are: spreadsheet. It is possible to view several telephone.
• Automatic Data Retrieval; curves simultaneously in the Curve The message contains the identity of the
• New Password System; and Viewer, making it easy to compare and switch, the abnormal condition and the
• User Defined Curves. coordinate multiple devices in the cause of the condition. It is also possible
The advanced features are: network. This is very useful if grading is to add a customised message such as
• Configurable IOEX; difficult and the curve can be 'moved' to directions to the switch. Upon receiving
• WSOS Monitoring System; and achieve the required discrimination. the message the operator can dial the
• A DNP Configuration tool. Configurable IOEX WSOS control room and use DTMF
Automatic Data Retrieval With the configurable IOEX tool it is control to acknowledge, select and operate
The Automatic Data Retrieval (ADR) possible to change the standard IOEX the switchgear. Pre-recorded voice
feature enables utilities to automatically setup and to customise the input/output messages are used to inform the remote
download a selection of switchgear data effects of the IOEX inputs. It is possible operator and prompt the person for further
during off-peak periods on the to combine logic functions with the input action.These messages are in.WAV file
communications network. To configure triggers to control the switchgear. For format and can be translated into other
the download periods simply select the example it is possible to use Input 1 to languages if required.
Day of the Week, Frequency (daily, always trip the switch. Input 2 can be In addition to the callout the system also
weekly, fortnightly or monthly), Start used to trip the switch if Protection sends out an e-mail notification. The
and End times. The next step is to setup group A or B is active. notification includes the last 50 events in
the download data profile. This can be The IOEX outputs are controlled by the message. In general this message will
any combination of the event log, combining logic functions and be sent to a different e-mail address
demand data, configurable history and switchgear status. As an example it is (example the protection engineer) to assist
switchgear settings. ADR uses the possible to activate Output 1 if a switch in analysing the cause of the callout.
default WSOS communications settings is tripped manually and activate Output 2 DNP Configuration Tool
or an additional profile specifically for if the switch tripped due to an over The DNP Configuration tool allows users
using ADR. current and Protection Group B is active. to customise the points monitored and
New Password System It is also possible to control IOEX controlled through a DNP3 SCADA
To offer better security, WSOS now has Outputs with a SCADA system using system. The customised mapping and I/O
an additional password system. The new DNP3 protocol. This feature extends the logic are created using the tool and saved
password system has separate passwords SCADA system beyond the recloser to to a DNP3 mapping file on the WSOS
for: devices without communication abilities. computer. This file is linked to the
• Switch Operation It would therefore be possible to monitor switchgear device configuration in WSOS
• Protection Settings external alarms like Bucholz, winding while Off-line (disconnected) from the
• Telecontrol Settings and temperature. switchgear. Once this is completed the
• System Access and Monitoring System user connects to the switchgear and writes
• Remote Write Access. The WSOS Switchgear Monitoring the new mapping into the controller along
It is therefore necessary to enter both the System reports Abnormal Conditions to with the switchgear device configuration.
Remote Write Access and data group control room and technical staff. The tool
WSOS Version2 Software release in
passwords to remotely change settings on enables the switchgear to automatically
January 2003. To access downloads &
the switch. For example the remote user dial in via radio or modem and report
upgrades visit
has to enter the Write Access and various state changes to WSOS in the
Protection passwords to change the control room. These points are monitored http://www.nulec.com.au
protection settings. by the monitoring system. If an
Click on Download section and follow
User Defined Curves Abnormal Condition occurs the system
the software links.
The User Defined Curves (UDC) feature can alarm locally or send callouts and

Our
Products

U-Series RL-Series
N-Series W-Series

You might also like