FORM NO.

G11-501
Supersedes Form No. G11-501

GAS FURNACES
“Visit www.RheemAC.com/
taxcredit for complete details.”

95% A.F.U.E. WITH DUAL


COMFORT CONTROL
TWO-STAGE UPFLOW
GAS FURNACES
The Rheem Classic ® Series 95% A.F.U.E. with Dual Comfort Control
line of upflow gas furnaces are designed for utility rooms, closets,
alcoves, or attics. Because of the low-profile 34 inch [864 mm]
height, the upflow model can also be used to satisfy most
applications.
The design is certified by CSA.
RGRM- SERIES Features
ECM Equipped ■ Two stages of operation to save energy and maintain optimal com-
fort level.
Models with Input Rates of ■ Furnace operates at 70% capacity for low-heat and 100% capacity
45,000, 60,000, 75,000, for high-heat.
■ Compatible with single or two-stage thermostat. (For optimal perfor-
90,000, 105,000 & 120,000 mance a two-stage thermostat is recommended.)
BTU/HR [13.19, 17.58, 22, ■ Heat exchanger is constructed of all stainless steel for maximum

26.38, 30.77 & 35.17 kW] corrosion resistance and thermal fatigue reliability.
■ Low profile “34 inch” design is lighter and easier to handle and
(45K through 105K Models leaves room for optional accessories.
Rated at 95% A.F.U.E., 120K ■ Left or right side gas, electric, and condensate drainage connections.
■ Integrated control board manages all operational functions and pro-
Model Rated at 93.3% A.F.U.E.) vides hookups for humidifier and electronic air cleaner.
■ An insulated blower compartment, a slow-opening gas valve and a
specially designed inducer system make it one of the quietest fur-
naces on the market today.
■ Variable speed blower motor technology provides ultimate humidity
control, quieter sound levels and year-round energy savings.
■ Optional indoor or outdoor combustion air. In addition, combustion
air may be piped to either the top or side of the cabinet on all upflow
models. A special molded fitting is provided to ease installation.
■ Solid bottom is standard.
■ Control board diagnostics.
A variety of cooling coils and plenums designed to use with the Rheem
Classic ® Series 95% A.F.U.E. gas furnaces are available as optional
accessories for air conditioning models.
✝A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test
procedures.

“Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be
matched with appropriate coil components to meet ENERGY STAR criteria. Ask your Contractor for details or visit www.energystar.gov.”
CLASSIC SERIES 90 PLUS HIGH EFFICIENCY
UPFLOW GAS FURNACE
REMOTE
SENSOR

DIRECT SPARK IGNITION &


REMOTE SENSOR

PRIMARY AND SECONDARY


HEAT EXCHANGER

IN-SHOT BURNERS GAS VALVE AND


MANIFOLD

PRESSURE SWITCHES

DRAFT INDUCER

INTEGRATED
FURNACE
CONTROL
ECM MOTOR

STANDARD EQUIPMENT OPTIONAL EQUIPMENT


Completely assembled and wired; heat exchanger; primary: 409 stainless steel, Side and bottom filter racks; return air cabinet for all sizes.
secondary: 29-4C stainless steel; induced draft; pressure switches; redundant NOTE: Furnace is not listed for use with fuels other than natural or L.P.
main gas control; blower compartment door safety switch; solid state time (propane) gas.
on/off blower control; limit controls; manual shut-off valve; 100% safety lock All models can be converted by a qualified distributor or local service dealer to
out; cool fan off delay; field selectable heat fan off delay; one hour automatic use L.P. (propane) gas without changing burners. Factory approved kits must
retry; power and self-test diagnostics; flame sense current diagnostics; be used to convert from natural to L.P. (propane) gas and may be ordered as
electronic air cleaner connections; twinning (built-in) features; humidifier optional accessories from a parts distributor.
connections; humidifier on/off delay; low speed continuous fan option; single
speed option for heating and cooling applications; pressure regulator for For L.P. (propane) operation, refer to Conversion Kit Index Form.
natural and L.P. (propane) gasses; transformer; direct drive, multi-speed blower
motor. (Please note: a thermostat is not included as standard equipment.)
WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED
FOR USE IN MOBILE HOMES
2 Rheem Heating, Cooling and Water Heating
BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE
FROM YOUR RETAILER.

PHYSICAL DATA AND SPECIFICATIONS—UPFLOW MODELS


U.S. and Canadian Models
MODEL NUMBERS RGRM-04*MAES RGRM-06*MAES RGRM-07*MAES RGRM-07*YBGS RGRM-09*ZAJS RGRM-10*ZAJS RGRM-12*RAJS
HIGH FIRE INPUT BTU/HR [kW] ➀ 45,000 [13.19] 60,000 [17.58] 75,000 [21.98] 75,000 [21.98] 90,000 [26.38] 105,000 [30.77] 120,000 [35.17]
LOW FIRE INPUT BTU/HR [kW] ➁ 31,500 [9.23] 42,000 [12.31] 52,500 [15.39] 52,500 [15.39] 63,000 [18.46] 73,500 [21.54] 84,000 [24.62]
HEATING CAPACITY BTU/HR [kW] 42,000 [12.31] 56,000 [16.41] 70,000 [20.51] 70,000 [20.51] 84,000 [24.62] 97,000 [28.43] 113,000 [33.12]
HIGH ALTITUDE INPUT 8000' ➁ 30,600 [8.97] 40,800 [11.96] 51,000 [14.95] 51,000 [14.95] 61,200 [17.94] 71,400 [20.93] 81,600 [23.91]
HIGH ALTITUDE OUTPUT
28,458 [8.34] 37,944 [11.12] 47,430 [13.90] 47,430 [13.90] 56,916 [16.69] 66,402 [19.46] 75,888 [22.24]
AT 8000' (HIGH FIRE) [kW] ➁
BLOWER (D x W) 11 x 7 11 x 7 11 x 7 12 x 7 12 x 11 12 x 11 11 x 10
[mm] [279 x 178] [279 x 178] [279 x 178] [305 x 178] [305 x 279] [305 x 279] [279 x 254]
MOTOR H.P. [W]– 1/2 [373] VAR. 1/2 [373] VAR. 1/2 [373] VAR. 1 [746] VAR. 1 [746] VAR. 1 [746] VAR. 1 [746] VAR.
SPEEDS–TYPE SPEED SPEED SPEED SPEED SPEED SPEED SPEED
MOTOR FULL LOAD AMPS 8.7 8.7 8.7 12 12 12 12
MINIMUM EXT. STATIC
.10 [0.25] .12 [.029] .12 [.029] .12 [.029] .15 [.037] .20 [.049] .20 [.049]
PRESSURE (IN. W.C.) [kPa]
MAXIMUM EXT. STATIC
.80 [0.2] .80 [0.2] .80 [0.2] .80 [0.2] .80 [0.2] .80 [0.2] .80 [0.2]
PRESSURE (IN. W.C.) [kPa]
LOW HEATING CFM @ .2"
850 725 765 1180 1275 1400 1250
[.049 kPa] W.C. E.S.P. [L/s]
HIGH HEATING CFM @ .2"
780 900 1080 1180 1450 1604 1450
[.049 kPa] W.C. E.S.P. [L/s]
A = 1200 A = 1200 A = 1200 A = 1600 A = 2000 A = 2000 A = 2000
HIGH COOLING CFM @ .8" B = 1000 B = 1000 B = 1000 B = 1400 B = 1600 B = 1600 B = 1600
[.124 kPa] W.C. E.S.P. [L/s] C = 800 C = 800 C = 800 C = 1200 C = 1400 C = 1400 C = 1400
D = 600 D = 600 D = 600 D = 1000 D = 1200 D = 1200 D = 1200
A = 900 A = 900 A = 900 A = 1200 A = 1500 A = 1500 A = 1500
LOW COOLING CFM @ .8" B = 750 B = 750 B = 750 B = 1050 B = 1200 B = 1200 B = 1200
[.124 kPa] W.C. E.S.P. [L/s] C = 600 C = 600 C = 600 C = 900 C = 1050 C = 1050 C = 1050
D = 450 D = 450 D = 450 D = 750 D = 900 D = 900 D = 900
TEMPERATURE RISE-HIGH FIRE 30-60 40-70 40-70 35-65 35-65 40-70 50-80
RANGE IN DEGREES °F [°C] [16.7-33.3] [22.2-38.9] [22.2-38.9] [19.4-36.1] [19.4-36.1] [22.2-38.9] [27.8-4.4]
TEMPERATURE RISE-LOW FIRE 15-45 35-65 35-65 20-50 25-55 30-60 40-70
RANGE IN DEGREES °F [°C] [8.3-25] [19.4-36.1] [19.4-36.1] [11.1-27.8] [13.9-30.6] [16.7-33.3] [22.2 – 38.9]
MAX. OUTLET AIR TEMPERATURE 160 170 180 170 165 180 180
RETURN AIR CABINETS (OPT.)
C17B C17B C17B C21B C21B C21B C24B
RXGR-
(2) 12" x 16" (2) 12" x 16" (2) 12" x 16" (2) 12" x 20" (2) 12" x 20" (2) 12" x 20" (2) 14" x 16"
FILTER SIZE
[305 x 406] [305 x 406] [305 x 406] [305 x 508] [305 x 508] [305 x 508] [609 x 406]
[mm]
STANDARD, HIGH VELOCITY
153/4 x 25 x 1 153/4 x 25 x 1 153/4 x 25 x 1 153/4 x 25 x 1 191/4 x 25 x 1 191/4 x 25 x 1 223/4 x 25 x 1
PERMANENT FILTER (IN.)
APPROX. SHIPPING WEIGHT 117 123 128 139 148 150 159
(LBS.) [kg] [53.2] [56.0] [58.2] [63.2] [67.3] [68.2] [72.3]
AFUE ➂ 95.0% 95.0% 95.0% 95.0% 95.0% 95.0% 93.3%
NOTES: All models are 115V, 60HZ, 1 phase. Gas connection size for all models is 1/2" [13 mm] N.P.T. WARNING: Some heating airflow values may be
➀ See Conversion Kit Index Form for high altitude derate. higher than those required for cooling. Be sure to size
➁ Canadian installations only. duct systems for highest possible airflow value.
➂ In accordance with D.O.E. test procedures.
*E=Standard
*N=NOx Models

Rheem Heating, Cooling and Water Heating 3


MODEL IDENTIFICATION
R G R M — 07E* Y B G S 278

Rheem Gas Upflow Design Heating Input Blower Size Variations Heat/Cool Fuel Code Option Code
Furnace Condensing Series Designation M = 11 x 7 A = Std. Designation S = U.S. and for
Gas Furnace [279 x 178 mm] B = Wide E = 1100-1300 CFM Canadian High Altitude
Electric Input R = 11 x 10 [519-613.5 L/s]
Ignition BTU/HR [279 x 254 mm] G = 1500-1700 CFM
Z = 12 x 11 [707.9-802.3 L/s]
04* 45,000 [13.19 kW] [305 x 279 mm] J = 1900-2100 CFM
06* 60,000 [17.58 kW] Y = 12 x 7 [896.7-991.1 L/s]
07* 75,000 [22 kW] [305 x 178 mm]
09* 90,000 [26.38 kW] Available Models:
10* 105,000 [30.77 kW] RGRM-04EMAES RGRM-07EMAES RGRM-09EZAJS278
12* 120,000 [35.17 kW] RGRM-04NMAES RGRM-07NMAES RGRM-10EZAJS
NOTES: *E = Standard RGRM-04EMAES278 RGRM-07EYBGS RGRM-10NZAJS
*N = NOx Models RGRM-06EMAES RGRM-07NYBGS RGRM-12ERAJS
RGRM-06NMAES RGRM-09EZAJS RGRM-12NRAJS
RGRM-06EMAES278 RGRM-09NZAJS RGRM-12ERAJS78

[ ] Designates Metric Conversions

4 Rheem Heating, Cooling and Water Heating


UPFLOW MODELS

MINIMUM CLEARANCE (IN.) [mm]


MODEL LEFT
A B C D E F RIGHT
RGRM- SIDE BACK TOP FRONT VENT
SIDE
04*M 17.5 [445] 1611/32 [415] 155/8 [397] 2 [51] 151/2 [422] 1325/32 [352] 0 0 0 1 [25] 2 [51] 0
06*M 17.5 [445] 1611/32 [415] 155/8 [397] 2 [51] 151/2 [422] 1325/32 [352] 0 0 0 1 [25] 2 [51] 0
07*M 17.5 [445] 1611/32 [415] 155/8 [397] 2 [51] 151/2 [422] 1325/32 [352] 0 0 0 1 [25] 2 [51] 0
07*Y 21 [533] 1927/32 [504] 191/8 [487] 2 [51] 181/2 [511] 179/322 [441] 0 0 0 1 [25] 2 [51] 0
09*Z 21 [533] 1927/32 [504] 191/8 [487] 2 [51] 181/2 [511] 179/322 [441] 0 0 0 1 [25] 2 [51] 0
10*Z 21 [533] 1927/32 [504] 191/8 [487] 2 [51] 181/2 [511] 179/322 [441] 0 0 0 1 [25] 2 [51] 0
12*R 24.5 [622] 2311/32 [593] 225/8 [575] 2 [51] 221/2 [600] 2025/32 [530] 0 0 0 1 [25] 2 [51] 0
*E=Standard
* N=NOx

[ ] Designates Metric Conversions Rheem Heating, Cooling and Water Heating 5


BLOWER PERFORMANCE DATA**—RGRM MODELS
CFM [L/s] AIR DELIVERY
BLOWER ECM EXTERNAL STATIC PRESSURE
MODEL BLOWER
SIZE (D x W) MOTOR INCHES WATER COLUMN [kPa]
RGRM- SPEED
IN. [mm] H.P. [W]
0.1 [.02] – 0.8 [.20]
HIGH 1200 [566]
11 x 7 1/2 MED-HI 1000 [472]
RGRM-04*M
[279 x 178] [373] MED 800 [378]
LOW 600 [283]
HIGH 1200 [566]
11 x 7 1/2 MED-HI 1000 [472]
RGRM-06*M
[279 x 178] [373] MED 800 [378]
LOW 600 [283]
HIGH 1200 [566]
11 x 7 1/2 MED-HI 1000 [472]
RGRM-07*M
[279 x 178] [373] MED 800 [378]
LOW 600 [283]
HIGH 1600 [755]
12 x 7 1 MED-HI 1400 [661]
RGRM-07*Y
[305 x 279] [746] MED 1200 [566]
LOW 1000 [472]
HIGH 2000 [944]
12 x 11 1 MED-HI 1600 [755]
RGRM-09*Z
[305 x 279] [746] MED 1400 [661]
LOW 1200 [566]
HIGH 2000 [944]
12 x 11 1 MED-HI 1600 [755]
RGRM-10*Z
[305 x 279] [746] MED 1400 [661]
LOW 1200 [566]
HIGH 2000 [944]
11x 10 1 MED-HI 1600 [755]
RGRM-12*R
[279 x 254] [746] MED 1400 [661]
LOW 1200 [566]
*E=Standard
*N=NOx Models

[ ] Designates Metric Conversions

GENERAL TERMS OF LIMITED WARRANTY


Rheem will furnish a replacement for any part of this product Primary and Secondary Heat Exchanger.......Limited Lifetime
which fails in normal use and service within the applicable Conditional Parts Warranty
period stated, in accordance with the terms of the limited (Registration Required)..............................Ten (10) Years
warranty. Conditional Unit Replacement Warranty
For Complete Details of the Limited Warranty, Including Applicable Terms (Registration Required)..............................Ten (10) Years
and Conditions, See Your Local Installer or Contact the Manufacturer for
a Copy.

6 Rheem Heating, Cooling and Water Heating


ACCESSORIES—UPFLOW
VENT TERMINATION KITS CONCENTRIC: HORIZONTAL/ FOR HIGH ALTITUDES:
VERTICAL = HIGH ALTITUDE KIT:
RXGY-E03A (US & Canadian Installations) INPUT BTU/HR [kW] HIGH ALTITUDE KIT NO.
HORIZONTAL TWO PIPE: RXGY-D02, RXGY-D03, RXGY-D04 RGRM-04*M RXGY-F18
(US Installations) RGRM-06*M RXGY-F18
RXGY-D02A, RXGY-D03A, RXGY-D04A (Canadian Installations) RGRM-07*M Not Required
RGRM-07*Y Not Required
RXGY-G02 (US Only)
RGRM-09*Z RXGY-F20
CONDENSATE PUMP KIT: RXGY-B01 RGRM-10*Z Not Required
NEUTRALIZER KIT: RXGY-A01 RGRM-12*R RXGY-F21
FOSSIL FUEL KIT: RXPF-F01, RXPF-F02 (TVA) Option – 278 furnaces are shipped with #51 DMS orifices installed.
RETURN AIR PLENUM: RXGR-C17B, RXGR-C21B, RXGR-C24B This is one drill size smaller than standard furnaces to account for
expected average elevations and heating values typically seen in
these areas.
PLENUM DATA FOR “A” COILS CAUTION: Always follow National Fuel Gas Code (NFGC) guidelines
Plenum adapters are required in some instances for use on upflow when converting for high altitudes.
applications when plenum and furnace size do not match.
For all installations above 2000 ft. (including all option – 278
FURNACE PLENUM models), the burner orifice size needs to be recalculated and
PLENUM ADAPTER COIL
WIDTH WIDTH verified. A burner orifice change may still be required. See
UPFLOW PLENUM
IN. [mm] IN. [mm]
Installation Instructions for more information.
141/2 [356] 161/4 [413] RXAA-C171 RXAL-B16BU
141/2 [356] 201/4 [514] RXAA-C172 RXAL-B20BU NOTE: For Canadian installations only, an optional derate (manifold
171/2 [445] 161/4 [413] RXAA-C185 RXAL-B16BU
gas pressure reduction) method may be used to adjust the
furnace for altitude. See Installation Instructions for more
171/2 [445] 201/4 [514] RXAA-C173 RXAL-B20BU
information. This optional method may NOT be used for
171/2 [445] 215/8 [549] RXAA-C187 RXAL-B21BU
U.S. installations.
171/2 [445] 251/4 [641] RXAA-C174 RXAL-B25BU
21 [533] 251/4 [641] RXAA-C175 RXAL-B25BU
(U.S. Models—Kit packaged with furnace.
Requires field installation).
21 [533] 221/4 [565] RXAA-C176 RXAL-B22BU
21 [533] 215/8 [549] RXAA-C188 RXAL-B21BU
Note: 1/2 [622]
24See 251/C11-206
Form Number RXAA-C177
4 [641] for MultiFlex ®
coil data. RXAL-B25BU
241/2 [622] 215/8 [549] RXAA-C187 RXAL-B21BU
Note: See Form Number C11-206 for MultiFlex® coil data.

LP CONVERSION KITS:
U.S./Canadian RXGJ-FP19 or RXGJ-FP21

EXTERNAL BOTTOM FILTER RACK: RXGF-CB


EXTERNAL SIDE FILTER RACK: RXGF-CA
FILTER RACK FILTER SIZES* INCHES [mm]
MODEL RXGF-CB RXGF-CA
RGRM- (BOTTOM) (SIDE)
153/4 x 25 153/4 x 25
04
[400 x 635] [400 x 635]
153/4 x 25 153/4 x 25
06
[400 x 635] [400 x 635]
07EM 153/4 x 25 153/4 x 25
07NM [400 x 635] [400 x 635]
07EY 191/4 x 25 153/4 x 25
07NY [489 x 635] [400 x 635]
191/4 x 25 153/4 x 25
09
[489 x 635] [400 x 635]
191/4 x 25 153/4 x 25
10
[489 x 635] [400 x 635]
223/4 x 25 153/4 x 25
12
[578 x 635] [400 x 635]
*Filter racks are shipped without filters.
Filters shipped with furnace may be used or a suitable 1" [25.4 mm] filter.

Rheem Heating, Cooling and Water Heating 7


[ ] Designates Metric Conversions
Before proceeding with installation, refer Rheem Heating,
to installation instructions packaged Cooling and
with each model, as well as complying
with all Federal, State, Provincial, and
Water Heating
Local codes, regulations, and practices. P.O. Box 17010, Fort Smith, AR 72917

“In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.”
PRINTED IN U.S.A. 5-09 DC FORM NO. G11-501
Supersedes Form No. G11-501 Rev. 5