You are on page 1of 3

Unit Rate

Item Description Unit Qty. Amount (RM)


(RM)

A. AIR COOLED SPLIT UNITS.

1. Labour charge to dismantle & relocated existing air cooled


split unit c/w necessary accessories.
Unit No. : FCU-2nd-02 (25,000 Btu/hr) Set. 1

Unit No. : FCU-2nd- 07 (10,000 Btu/hr) Set. 1

2. To supply and install air conditioning Split Units complete


sets c/w other necessary outdoor support as per specified
capacity :-

i. Wall Mounted Type.


- Unit No. : FCU-2nd-04 Set. 1
- Model : YSL 10C / YWM 10G (Essential)
- Capacity : 10,000 Btu/hr

- Unit No. : FCU-2nd-05 Set. 1


- Model : YSL 10C / YWM 10G (Essential)
- Capacity : 10,000 Btu/hr

- Unit No. : FCU-2nd-08 Set. 1


- Model : YSL 10C / YWM 10G (Essential)
- Capacity : 10,000 Btu/hr

- Unit No. : FCU-2nd-09 Set. 1


- Model : YSL 10C / YWM 10G (Essential)
- Capacity : 10,000 Btu/hr

- Unit No. : FCU-2nd-06 Set. 1


- Model : YSL 15C / YWM 15G (Essential)
- Capacity : 13,000 Btu/hr

ii. Ceiling Cassette Type.


- Unit No. : FCU-2nd-03 Set. 1
- Model : YSL 18C / YCK 20AL
- Capacity : 18,000 Btu/hr

Carried forward

Page 1
Unit Rate
Item Description Unit Qty. Amount (RM)
(RM)
Balance forward

3. To supply and install refrigenat pipe c/w insulation, bracket Lot. 1


suport, hanger and accessories.

4. To supply and install power wiring, control wiring in Lot. 1


conduit/trunking, support c/w accessories.

5. To supply and install condansate drain pipe c/w insulation Lot. 1


and accessories.

6. To supply and install incoming air conditioning power Lot. 1


point tapped from nearest DB.

B. AIR COOLED DUCTED UNITS.

1. Air Cooled Ducted Unit and Condensing Units complete


sets c/w other necessary outdoor support as per specified
capacity :-

- Unit No. : FCU-2nd-01 Set. 1


- Model : MYSS 100B / YSB 100B
- Capacity : 100,000 Btu/hr

2. To supply & install 1 lot supply and return air ductwork Lot. 1
c/w fiberglass insulation, mixing box, bracket support,
hanger and accessories.

3. To supply and install supply air diffuser & grille c/w Lot. 1
volume control damper and accessories.

4. To supply and install refrigerant pipes c/w insulation, Lot. 1


bracket support, hanger and accessories.

5. To supply and install power wiring, control wiring in Lot. 1


conduit/trunking, support c/w accessories.

6. To supply and install condansate drain pipe c/w insulation Lot. 1


and accessories.

Carried forward

Page 2
Unit Rate
Item Description Unit Qty. Amount (RM)
(RM)
Balance forward

7. To suppy and install air conditioning control panel c/w Lot. 1


accessories.

8. To supply and install incoming power cable to air Lot. 1


conditioning control panel.

C. GENERAL ITEMS.

1. Preliminaries. L/S
- Moblization
- Dosumentation
- Shop drawing
- Transportation
- Hoisting

2. Hacking work, making good & touch-up. L/S

3. Testing and commissioning L/S

Page 3