Ultrasonic Level Transmitter


Specifications
Rear View Shown
Range: LU81: 4" to 16.4'
LU81/83/84
(10 cm to 5m)
Shown
LU83: 8" to 26.2'
(20 cm to 8m)
LU84: 12" to 32.8'
(30 cm to 10m)
Accuracy: ± 0.2% of span in air
Resolution: LU81/83: 0.039" (1 mm)
LU84: 0.078" (2 mm)
Beam width: 3" (7.6 cm) dia.
Dead band: LU81: 4" (10 cm)
LU83: 8" (20 cm)
LU84: 12" (30 cm)
Display type: LCD, 6-digit
Display units: Inch, cm or percent
Display mode: Air gap or liquid height Faceplate
Memory: Non-volatile Shown
Supply voltage: 12-28 VDC
Loop resist.: 500 Ohms @ 24 VDC IP
65
Signal output: 4-20 mA, two-wire
Signal invert: 4-20 mA or 20-4 mA
Calibration: Push button
Fail-safety: Selectable 4mA, 20mA,
21 mA, 22 mA or hold Description Features
Process temp.: F: -4˚ to 140˚ The general purpose two-wire ultra- Setup is fast and simple with push
C: -20˚ to 60˚
sonic transmitter provides non-con- button calibration and LCD display
Temp. comp.: Automatic
Electronics temp.: F: -40˚ to 160˚ tact level measurement up to 32’ or
C: -40˚ to 71˚ 10m, and is ideally suited for chal- Offered in three measurement
Pressure: 30 psi (2 bar) @ 25˚ lenging ultrapure, corrosive or ranges up to 10m with 2” transducer
C., derated @ 1.667
waste liquids. Push button calibrat-
psi (.113 bar) per ˚C. 6-segment LCD display indicates
above 25˚ C. ed, the transmitter is broadly select-
level in inch or centimeter values
Enclosure rating: NEMA 4X (IP65) ed for atmospheric bulk storage,
Enclosure vent: Water tight membrane day tank and waste sump applica- 7.6 cm minimum beam width for
Encl. material: PC/ABS FR tions. Media examples include
Trans. material: PVDF applications with restricted space
Process mount: 2" NPT (2" G)
wastewater and sodium hydroxide.
Mount. gasket: Viton® Selectable display indicates level
Conduit entrance: Dual, 1/2" NPT in air gap or liquid height
Classification: General purpose
CE compliance: EN 61326 EMC PC/ABS enclosure rated NEMA
4X with rugged PVDF transducer

Fail-safe intelligence with diagnostic


feedback for easy troubleshooting
EchoSpan Ordering
Ordering Notes
LU -51 1 1) For installation on open tanks, order the
Sensor range LM50-1001 (2" NPT) or LM50-1061 (2" G)
81 5m (16.4') side mount bracket.
83 8m (26.2') 2) For a liquid tight cable connection, order
84 10m (32.8') the LM90-1001 connector.
Process mount (1) (2)
0 NPT (US)
6 G (Metric)

10500 Humbolt Street • Los Alamitos, CA 90720 • www.flowline.com • T (562) 598-3015 • F (562) 431-8507
EchoSpan
TM

Ultrasonic Level Transmitter

Side View Top View


5.2" (133 mm) 5.2" (133 mm)

3.8" (96 mm)


4.1" (104 mm)
5.5" (138 mm)
4.0" (100 mm)
3.4" (88 mm)

2" NPT (2" G)


2.7" (69 mm)

Specifications are subject to change without notice.

Menu
DISPLAY

SELECT / FAST TOP MENU


Button

UNITS TANK SAFE TGCAL VALUES HELP RUN

To activate the top


menu, press and
hold SELECT / FAST SELECT SELECT SELECT SELECT SELECT SELECT
button for 5 seconds Display Units 4-20 Span Fail-Safety Target-Cal Diagnostics Help

Inches Height (4 mA) 22 mA Full Setup Contact


Centimeters Fill H (20 mA) 21 mA Empty Diagnostics
Percentage Reverse mA 20 mA Help Reset
Display Help 4 mA
Hold

To LC52 Relay Controller To LI42 MicroPoint Display


Shield Shield DC Power
POSITIVE P W R LATCH R E L AY 1 R E L AY 2
POSITIVE Supply
ON OFF INVERT INVERT
NEGATIVE
DELAY DELAY
NEGATIVE 12-24 VDC

+ -
OFF SET

RLY2A

RLY2B
SPAN

RLY1

E A S Y CAL
4 20 OP

UP DOWN SET
ORANGE
0% INPUT 100%

BLACK

RED

BROWN
Controller in
JWA mode

To PLC To LI1_ Universal Panel Meter


Universal Panel Meter
Shield DC Power 7 Shield
LI1_ Series
POSITIVE Supply 6 POSITIVE
A H C
12-28 VDC 5 C L O
Typical PLC

NEGATIVE
NEGATIVE S D M S+ S- P- P+ L L
+ - 4
3
2
1 VAC
0 Power

10500 Humbolt Street • Los Alamitos, CA 90720 • www.flowline.com • T (562) 598-3015 • F (562) 431-8507