Surface & Coatings Technology 201 (2007) 6340 – 6344

www.elsevier.com/locate/surfcoat

Influence of thermal shock on insulation effect of nano-multilayer


thermal barrier coatings
Chunxia Zhang, Chungen Zhou, Hui Peng, Shengkai Gong ⁎, Huibin Xu
School of Materials Science and Engineering, Beijing University of Aeronautics and Astronautics, Beijing, 100083, China
Received 15 May 2006; accepted in revised form 29 November 2006
Available online 11 January 2007

Abstract

Thermal barrier coatings (TBCs) with nano-multilayer structure were investigated by thermal shock test. The change of insulation effect during
thermal shock test was studied by in-situ temperature monitor with a thermal couple set into the substrate. Microstructure and electrical properties
of TBCs were characterized by SEM and Impedance Spectroscopy, respectively. Initial increase in insulation effect was observed and related to the
formation and growth of perpendicular microcracks in top coat and transversal microcracks in TGO. With thermal shock, the insulation effect
decreased due to the further growth of microcracks in top coat and TGO which induced the failure of TBCs.
© 2006 Elsevier B.V. All rights reserved.

Keywords: Insulation effect; Thermal barrier coatings; Thermal shock; Nano-multilayer

1. Introduction introduce interfaces into each column structure which are


essentially parallel to the ceramic/bond coat interface, but
Increasing attention has been paid to ceramic thermal barrier without disrupting the columnar structure that provides the EB-
coatings (TBCs) for advanced gas turbine engine applications. PVD coating with good strain tolerance and erosion resistance.
Because of its higher strain tolerance and longer liftetime, EB- The other is nano-structure coating because grain boundaries
PVD (Electron beam physical vapor deposition) TBCs with have a significant effect on thermal conductivity.
columnar microstructure have been widely applied in turbine In the present work, yttria stabilized zirconia coatings with
blades [1–6]. In order to fully take advantage of the TBC nano-multilayer structure are prepared by electron beam
capability, reduction of the thermal conductivity of TBCs is physical vapor deposition. Its insulation effect after thermal
essential. shock (carried out in an infra-red heating instrument) is studied
To lower the thermal conductivity of EB-PVD TBCs, Zhu by in-situ temperature monitoring. The correlation of the
et al. [7] developed an advanced multi-component, low insulation effect with the microstructural evolution and
conductivity oxide thermal barrier coatings by adding rare Impedance Spectroscopy is investigated.
earth oxides such as Nd2O3, Gd2O3, Sm2O3, and Sc2O3. Hass
et al. [8] prepared low thermal conductivity yttria stabilized 2. Experimental details
zirconia coatings by a low vacuum electron beam directed vapor
deposition process. That top coat has lower thermal conductivity The TBCs system used in this study consists of an alumina-
because of its zig-zag pore microstructure which elongated the Yttria stabilized zirconia composite top coat with nano-
thermal diffusion path. Nicholls and his colleague Rickerby et al. multilayer structure and NiCoCrAlY bond coat prepared onto
[1,9] proposed two methods, one is a concept to reduce the hollow cylindrical superalloy substrate by EB-PVD. Cross-
thermal conductivity of EB-PVD TBCs by introducing addi- section morphology of the nano-multilayer ceramic top coat is
tional phonon scattering centers into the coatings, that is to shown in Fig. 3(a).
Thermal shock tests were performed in infra-red heating
⁎ Corresponding author. Tel.: +86 10 8231 7117; fax: +86 10 8233 8200. system (Model1:10K-HR-I, Crystal System Inc., Japan). The
E-mail address: gongsk@buaa.edu.cn (S. Gong). system consists of four high-power lamps whose light can be
0257-8972/$ - see front matter © 2006 Elsevier B.V. All rights reserved.
doi:10.1016/j.surfcoat.2006.11.042
C. Zhang et al. / Surface & Coatings Technology 201 (2007) 6340–6344 6341

Fig. 1. Schematic diagram for temperature measurement.

focused on a narrow area (about 20 mm) by four concave


mirrors to implement fast heating and high temperature. Heating
temperature is controlled by operating the heating power of
lamp. A thermocouple on the surface of a reference sample is
used to measure the surface temperature, then a calibration
curve for the heating power of lamp and the surface temperature
of the specimen is figured out. Thermal shock consists of 20 s
heating specimen to the surface temperature be about 1100 °C
and dwelling at that power for 5 min and ramp power from
heating power to zero in 20 s and dwelling at zero for 3 min and
forced air through the hollow during cooling and dwelling at
zero. During thermal shock, a thermocouple set in the substrate
(see Fig. 1) is connected with a computer through a digital volt
gauge to record the temperature in situ. The temperature
difference (the delta T) of the surface and the substrate is
measured by using the surface temperature calibrated according
to the heating power of the lamps and the substrate temperature
measured by thermocouple. In order to evaluate insulation
effect, heating speed of substrate during heating ramp is
calculated as a function of thermal shock.
For impedance measurement, the specimen surface is coated
with platinum gel (5 × 5 mm2) that served as an electrode and
the substrate is polished as another electrode. Impedance
Fig. 3. Morphology of as deposited top coating with nano-multilayer
measurements were carried out at 400 °C using a Solartron SI microstructure, (a) cross-section, and (b) surface.
1260 Impedance/gain-phase analyzer coupled with a Solartron
1296 Dielectric Interface, which is computer controlled. Spectra
analysis was performed using Zview impedance analysis (EDS). Specimen is embedded into the epoxy resin and cut by a
software (Scribner Associates, Inc., Southern Pines, NC). In diamond saw to obtain cross-section and then polished with a
the measurements, alternating current (AC) amplitude of diamond paste and etched with FeSO4, H2SO4, and alcohol
100 mV was employed and the AC frequency was in the solution prior to SEM observation. Surface morphology of
range of 0.01 Hz to 1 × 106 Hz. Microstructure and composition specimen is observed by multiple focus OLYMPUS optical
of specimen is examined by scanning electron microscopy microscope.
(SEM) coupled with energy dispersive X-ray spectroscopy
3. Results

3.1. Insulation effect

Fig. 2 shows the reverse of temperature difference between


surface and substrate as a function of thermal shock number.
Before 220 times, the curves can be divided into three parts,
stage I, II, and III, respectively. For stage I (from 0 to 25 times),
at the initial stage of thermal shock, the value decreases sharply.
With the increase of thermal shock, the curve decreases slowly
as fitted by stage II (from 25 to220 times), and then the value
increases slowly in stage III (above 220).

3.2. Microstructure as a function of thermal shock time

Fig. 2. The reverse of temperature difference between surface and substrate as Fig. 3(a)–(b) show the cross-section SEM image and the
function of thermal shock number. optical photo of surface for as received specimen. Al2O3/YSZ
6342 C. Zhang et al. / Surface & Coatings Technology 201 (2007) 6340–6344

prolonged. After 300 thermal shocks, there are cracks along the
interface of TGO and top layer. The cracks along the columnar
crystals are broadening.

3.3. Impedance Spectroscopy of thermal barrier coatings as a


function of thermal shock number

Fig. 6(a) and (b) show the Impedance Spectroscopy of


thermal barrier coatings as function of thermal shock number
for the low frequency range from 0.01 Hz to 1000 Hz, and for
high frequency range from 1000 Hz to 1,000,000 Hz,
respectively. For the low frequency range (Fig. 6(a)), the
impedance of thermal barrier coatings increases with increasing
thermal shock number, especially for the very low frequency
such as from 0.01 to 1 Hz. But for the system after 150 thermal
shocks, its impedance is even a little larger than system 200
thermal shocks. For system after 300 thermal shocks, its
impedance increases continually.
For the higher frequency range (Fig. 6(b)), the trend of
impedance with the thermal shock shows different results from
the lower frequency. From 0 to 30 thermal shocks, firstly the
impedance increases, then it decreases (from 30 to 150 thermal
shocks), and finally increase again (from 150 to 300 thermal
shocks).

Fig. 4. Morphology of the specimen after 30 thermal shocks, (a) cross-section,


and (b) surface.

composite ceramic nano-multilayer top coating is prepared by


EB-PVD to improve its thermal resistance. During deposition,
two sources, one is YSZ target, another is Al2O3 target, are
alternately evaporated. As shown in Fig. 3(a), the analysis
results by EDS show that the dark layers are Al2O3 layers and
the grey layers are YSZ layers. Al2O3 layers and YSZ layers are
alternative and continuous, and their thickness is less than
200 nm. From Fig. 3(b), columnar crystal druse and their grain
boundary can be seen from surface morphology of the top
coating, and the surface is smooth and no crack. On the other
hand, due to the roughness of the substrate and relatively fast
deposition speed, the ceramic layers show the fluctuations in
thickness.
Fig. 4(a)–(b) show the cross-section SEM image and optical
photo of surface for specimen after 30 thermal shocks. As
shown in Fig. 4(a) and (b), there are many cracks along the
columnar crystal. There are some holes localized at the bond
coat caused by the etching for SEM observation. And almost all
cracks end before reaching the interface of top coat and bond
coat.
The growth of TGO and cracks during thermal shock is
presented in Fig. 5(a) and (b) for specimens after 200 and 300
thermal shocks, respectively. Obvious TGO can be seen in Fig. 5. Morphology of cross-section for the specimen. (a) After 200 thermal
Fig. 5(a), and the cracks along the columnar crystals are shocks, and (b) after 300 thermal shocks.
C. Zhang et al. / Surface & Coatings Technology 201 (2007) 6340–6344 6343

4. Discussion

The thermal gradient tested in the experiment depends on the


microstructural features such as microcracks, defects, and micro
composition of the thermal barrier coatings such as TGO
formed during thermal shock. The effect of microcracks (which
are perpendicular to the plane of the film) on the thermal
conductivity of a film system can be expressed as [10],
 
knet ðNslab −1Þð1−aÞbg −1
¼ 1þ : ð1Þ
k 1−ð1−aÞg

Where k is the thermal conductivity of bulk material, knet is


the thermal conductivity of film-microcrack system, Nslab is the
number of slabs divided by microcracks, α is the thermal Fig. 7. Changes in reverses of impedance and ΔT for TBCs as function of
conductivity of the cracks, β is the size of cracks, and γ is the thermal shock.
fraction of cross-section of microcracks that they cover.
Therefore, the ratio of the thermal conductivities can be
quantitatively obtained by considering the factors of micro- number of slabs divided by microcracks (Nslab), the size of
cracks such as the number of slabs, the size of the cracks and cracks (β), and the fraction of cross-section of microcracks
the fraction of the cross-sectional area that they cover. For the that cover (γ) are increasing. That may be the reason that
top coat of thermal barrier coatings in the case of this paper, there is a sharp decline at stage I shown in Fig. 2. And also it
at the initial stage of thermal shock, the factors including the can be confirmed by the cross-section and surface morphol-
ogies of the system after 30 thermal shock shown in Fig. 4(a)
and (b).
After prolonging thermal shock, there is a slow decline as
stage II shown in Fig. 2. This may be due to the slow growth of
perpendicular microcracks and the formation of TGO as shown
in Fig. 5(a). The thermal conductivity of Al2O3 which is the
main composition of TGO is 0.02394 J/cm·s·k, that is larger
than YSZ but less than bond coat. For the number of the
perpendicular microcracks, it should not increase unlimitedly.
Therefore, there is a slow decline of thermal conductivity of
thermal barrier coatings.
After 220 thermal shocks, the parameter 1 / ΔT increases as
stage III shown in Fig. 2. At the same time, cracks with larger
size which are perpendicular to the film plane and along the
interface of top coat/bond coat are observed for system after
300 thermal shock, and some cracks even penetrate through
the top coat layer as shown in Fig. 5(b). In this situation, the
thermal conductivity of system would not follow the micro-
crack model any more. Heat flux would be easy to go through
the top coat layer to reach the substrate, and then the thermal
conductivity of TBCs is increased. On the other hand, the
sintering of the top coat during thermal shock is another
possible mechanism that can lead to an increase in thermal
conductivity.
According to Wiedemann-Franz (WF) law [11], about the
relationship of thermal conductivity (ê) and electrical conduc-
tivity (σ) for bulk materials, there is

j k2 j2B
¼C¼ : ð2Þ
rT 3 e2

Fig. 6. Impedance Spectroscopy of thermal barrier coatings as function of


Where k is thermal conductivity, σ is electric conductivity, T
thermal shock number, (a) low frequency range from 0.01 Hz to 1000 Hz, (b) is the measurement temperature, Γ is Lorenz number, kB is
high frequency range from 1000 Hz to 1,000,000 Hz. Boltzmann's constant, and e is electron charge.
6344 C. Zhang et al. / Surface & Coatings Technology 201 (2007) 6340–6344

According to the assumption proposed by Tien [12], and then some macrocracks formed. That may be the reason that
compared with bulk materials, the thermal conductivity and the impedance increases after 30 thermal shocks and then
electric conductivity for thin film can be expressed as, decreases for system after 150 thermal shocks and then
jfilm rfilm increases go on.
¼ : ð3Þ
jbulk rbulk
5. Summary
Where kfilm is thermal conductivity of the film, kbulk is the
thermal conductivity of the bulk material, σfilm is the electric Thermal conductivity of thermal barrier coatings with nano-
conductivity of the film, and σbulk is the electric conductivity of multilayer ceramic top layer is studied in this paper by in-situ
the bulk material. Then, the Eq. (2) can also be applied to the substrate temperature monitor and Impedance Spectroscopy
thin film materials and can be rewritten as, during thermal shock test. As function of thermal shock, change
of thermal conductivity and impedance is related to the micro-
kfilm structural changes such as the formation and growth of per-
¼ CT C: ð4Þ
rfilm pendicular microcracks, TGO growth. A decrease and then an
increase in the thermal conductivity and impedance at low
Therefore, at the temperature for the measurement, the ratio frequency are observed and discussed in terms of cracks and
of the kfilm to the σfilm is a constant. Then measurement results relationship of thermal conductivity and electrical conductivity.
of electric conductivity can be related with the thermal con- The cracks existed in TBCs can be characterized by system
ductivity of thermal barrier coatings system. Impedance Spec- thermal conductivity, and thermal conductivity can be evaluated
troscopy is used in thermal barrier coatings system to evaluate by using impedance value.
the failure process and monitor the chemical and physical
variation during service [13–15]. All the research results Acknowledgement
showed that the impedance at high frequency part gives the
information about YSZ layer, meanwhile, the low frequency This work is supported by the National Natural Science
part gives the information about TGO layer. The impedance Foundation of China under the contact 50546030 and
value at low frequency such as 0.01 Hz contained the YSZ and 50420130032.
TGO contributions totally. Therefore, the total impedance
value, |Z| at 0.0 1Hz was used to evaluate the total conductivity References
of TGO and YSZ. As shown in Fig. 6(a), the impedance values
at 0.01 Hz for samples after different shock number increase [1] J.R. Nicholls, J.J. Deakin, D.S. Rickerby, Wear 233–235 (1999) 352.
with the increasing of shock number, and that the trend is [2] SM. Meier, D.K. Gupta, et al., JOM 43 (1991) 50.
opposite to the 1 / ΔT showed in Fig. 2. The factors including the [3] R.A. Miller, Surf. Coat. Technol. 30 (1987) 1.
perpendicular cracks in ceramic layer and the formation and [4] J.A. Thornton, J. Vac. Sci. Technol., A, Vac. Surf. Films 12 (1975) 830.
[5] B.A. Movchan, JOM 48 (1996) 40.
growth of TGO that can influence the thermal conductivity also [6] U. Schulz, K. Fritstcher, et al., Mat. Sci. Forum 251–254 (1997) 957.
affect the impedance of TBCs system. The plots of the reverse [7] Zhu Dongming, Miller R.A. NASA/TM-2002-211481.
impedance at 0.01 Hz and the parameter 1 / ΔT versus the [8] D.D. Hass, A.J. Slifka, H.N.G. Wdley, Acta Mater. 49 (2001) 973.
thermal shock number are shown in Fig. 7. The two plots show [9] R.G. Wellman, J.R. Nicholls, Wear 242 (2000) 89.
similar trends. Therefore, the variation in thermal conductivity [10] A. Redondo, J.G. Beery, J. Appl. Phys. (60) (1986) 3882.
[11] G. Wiedemann, R. Franz, Ann. Phys. 89 (2) (1853) 497.
of thermal barrier coatings system as function of thermal shock [12] C.L. Tien, ASME J. Heat Transfer 116 (1994) 799.
can be characterized in terms of the impedance change to some [13] P.S. Anderson, X. Wang, et al., Surf. Coat. Technol. 185 (2004) 106.
degree. Meanwhile, the impedance at higher frequency may [14] S. Song, P. Xiao, Mater. Sci. Eng. B 97 (2003) 46.
show the crack growth rate for top coat. At initial thermal shock, [15] S.-H. Song, P. Xiao, et al., J. Eur. Ceram. Soc. 25 (2005) 1167.
the growth of microcracks is very fast, but after that, it gets slow,

You might also like