Professional Documents
Culture Documents
Introduction
Induction Reversible Synchronous
Motors
Motors
Torque
Watertight
Motors
Magnetic
Brake
Clutch &
Brake Motors Motors
Induction Motors
Brake
Pack
Right-Angle
Gearheads Accessories
Before Using
a Standard
AC Motor
1 W ············································································A-18
6 W ············································································A-20
15 W ··········································································A-24
25 W ··········································································A-28
40 W ··········································································A-34
Additional Information 60 W ··········································································A-40
Technical Reference················································F-1 90 W ··········································································A-47
General Information ················································G-1 200 W ········································································A-54
4090 W (2-Pole)······················································A-65
A-13
Standard AC Motors
Induction Motors
1/750 HP
1W
1/125 HP
6W
✽ Gearheads shown in the photograph are sold separately. The V Series and the BH Series are Combination Type. (Pre-assembled Gearmotor)
1/30 HP
25 W
Features
Optimal for Uni-Directional Continuous Operation Conform to Safety Standards and Global Power
1/19 HP
operation such as a conveyor system. Conforms to UL/CSA/EN standards and the CE Marking is
being used in accordance with the low voltage directive. Also,
Wide Variety of Products
1/12 HP
60 W
can select from lead wire type, terminal box type and conduit
90 W
A-14
Standard AC Motors
K Series
Standards Certification Body Standards File No. CE Marking
UL1004
UL E64199
UL519
CSA C22.2 No.100✽1
CSA LR47296 Low Voltage Directives
CSA C22.2 No.77✽1
Introduction
✽1 Only 1 W type.
✽2 Except 4IK40A-BA.
● Details of Safety Standard➝Page G-2
Motors
UL1004
UL2111
UL E64197
CSA C22.2 No.100
Motors
CSA C22.2 No.77
Low Voltage Directives
EN60950
EN60034-1
Motors
Torque
Conform to EN/IEC Standards
EN60034-5
IEC60034-11
Watertight
Motors
System Configuration
Magnetic
Brake
Brake Pack
SB50 (Sold separately)
Clutch &
Brake
(➝Page A-179)
Brake
Pack
Motor
Right-Angle
Gearheads Accessories
AC
Power
Supply
Before Using
Insulating cap for capacitor terminal section
a Standard
AC Motor
Gearheads (Sold separately)
Right-Angle Gearhead
(Sold separately)
(➝Page A-189)
A-15
Standard AC Motors
Product Number Codes
World K Series World K Series and K Series Gearheads
5 I K 40 GN - AW T U 5 GN 50 KA
Included Capacitor Type of Bearings and Shaft Type
Output Power
U: For Single-Phase KA: Ball Bearing Type (inch-size)
(Example)
110/115 VAC RAA: Right Angle Solid Shaft Type (inch size)
40: 40 W
E: For Single-Phase RH: Right Angle Hollow Shaft Type
1/750 HP
Note:
25 W
K Series
◆ 1 W Type, 2-Pole Type ◆ Conduit Box Type
1/12 HP
60 W
5 I K 90 A - B F UL 5 I K 40 GN - F C H
1/8 HP
90 W
Output Power F: With built-in cooling fan Motor Series F: Single-phase 110/115 VAC
(Example) K: K series E: Single-phase 220/230 VAC
90: 90 W Voltage and No.of Poles Motor Type S: Three-phase 200/220/230 VAC
A: Single-Phase 115 VAC, 4 Poles
1/19-1/8 HP
V Series BH Series
V H I 5 40 A T - 300 U BH I 6 2 F T - 5 RH
Motor Included Capacitor RH: Right-Angle Hollow Shaft
Series U: For Single-Phase RA: Right-Angle Solid Shaft
V: V Series 110/115 VAC
Number: Gear Ratio
E: For Single-Phase
High Power A: Round Shaft Type
220/230 VAC
Motor Type None: Three-Phase type T: Terminal Box Type
I: Induction motor None: Cable Type
Gear Ratio Voltage
Motor Frame Size (Example) 300: Gear Ratio of 300:1 F: Single-Phase 110/115 VAC
2: 2.36 in. sq. (60 mm sq.) E: Single-Phase 220/230 VAC
3: 2.76 in. sq. (70 mm sq.) T: Terminal Box Type S: Three-Phase 200/220/230 VAC
4: 3.15 in. sq. (80 mm sq.)
Output Power
5: 3.54 in. sq. (90 mm sq.) Voltage
2: 200 W
A: Single-Phase 100/110/115 VAC
C: Single-Phase 200/220/230 VAC Motor Frame Size
S: Three-Phase 200/220/230 VAC 6: 4.09 in. sq.
(104 mm sq.)
Output Power Motor Type
(Example) 40: 40 W I: Induction motor
Note: BH Series
● The "U" and "E" at the end of the model number indicate that the unit includes a
capacitor. These two letters are not listed on the motor nameplate.
A-16
Standard AC Motors
General Specifications
World K Series, V Series, K Series (Conduit Box Type)
Item Specifications
100 MΩ or more when 500 VDC is applied between the windings and the frame after rated motor operation under normal ambient
Insulation Resistance
temperature and humidity.
Sufficient to withstand 1.5 kV at 50 Hz and 60 Hz applied between the windings and the frame for 1 minute after rated motor operation under
Dielectric Strength
normal ambient temperature and humidity.
Introduction
Temperature rise of windings are 144˚F (80˚C) or less measured by the resistance change method after rated motor operation with
Temperature Rise
connecting a gearhead or equivalent heat radiation plate✽. [Three-Phase 6 W type : 126˚F (70˚C)]
Insulation Class Class B (266˚F [130˚C])
6 W type have impedance protection. All others have built-in thermal protector (Automatic return type)
Motors
Lead wire type (World K Series, V Series) : IP 20
Degree of Protection Terminal box type (World K Series, V Series) : 25 W, 40 W IP 54
60 W, 90 W IP 44
Motors
✽ Heat radiation plate (material: Aluminum)
Type (output) Size: in. (mm) Thickness: in. (mm)
Motors
Torque
2IK Type (6 W) 4.534.53 (115115)
3IK Type (15 W) 4.924.92 (125125)
4IK Type (25 W) 5.315.31 (135135)
Watertight
0.20 (5)
Motors
5IK40 Type (40 W) 6.506.50 (165165)
5IK60 Type (60 W) 7.877.87 (200200)
5IK90 Type (90 W) 7.877.87 (200200)
Magnetic
Brake
K Series
Clutch &
Item Specifications
Brake
100 MΩ or more when 500 VDC is applied between the windings and the frame after rated motor operation under normal ambient
Insulation Resistance
temperature and humidity.
Sufficient to withstand 1.5 kV at 60 Hz applied between the windings and the frame for 1 minute after rated motor operation under normal
Brake
Pack
Dielectric Strength
ambient temperature and humidity.
Temperature Rise Temperature rise of windings are 135˚F (75˚C) or less measured by the resistance change method after rated motor operation.
Right-Angle
Gearheads Accessories
Class A (221˚F [105˚C])
Insulation Class
(0IK1GN-AUL, 0IK1A-AUL, 5IK90A-BFUL: UL/CSA Standards···Class A, EN Standards···Class E)
1 W type is impedance protected. All others have built-in thermal protector (Automatic return type)
Overheat Protection
Operating temperature, open: 248˚F9˚F (120˚C5˚C) close: 170.6˚F27˚F (77˚C15˚C)
Ambient Temperature Range 14˚F104˚F (10˚C40˚C) (nonfreezing)
Ambient Humidity 85% maximum (noncondensing)
Degree of Protection IP20
Before Using
a Standard
AC Motor
BH Series
Item Specifications
100 MΩ or more when 500 VDC is applied between the windings and the frame after rated motor operation under normal ambient
Insulation Resistance
temperature and humidity.
Sufficient to withstand 1.5 kV at 50 Hz and 60 Hz applied between the windings and the frame for 1 minute after rated motor operation under
Dielectric Strength
normal ambient temperature and humidity.
Temperature rise of windings are 144˚F (80˚C) or less measured by the resistance change method after rated motor operation with
Temperature Rise
connecting a gearhead or equivalent heat radiation plate✽. [Three-Phase type: 126˚F (70˚C)]
Insulation Class Class B (266˚F [130˚C])
Built-in thermal protector (Automatic return type)
Overheat Protection
Operating temperature, open : 302˚F9˚F (150˚C5˚C) close : 204.8˚F27˚F (96˚C15˚C)
Ambient Temperature Range 14˚F104˚F (10˚C40˚C) [Three-Phase 200 VAC: 14˚F122˚F (10˚C50˚C)] (nonfreezing)
Ambient Humidity 85% maximum (noncondensing)
Cable Type: IP40
Degree of Protection
Terminal Box Type: IP54
✽ Heat radiation plate: 9.06 inch9.06 inch (230 mm230 mm), 0.20 inch (5 mm) thickness (Material: Aluminum)
A-17