•Specifications• AP - MDB - BR - 2140A

INDOOR MDB075BR MDB100BR MDB125CR - - MDB150BR2 MDB200BR2 MDB250BR2 MDB300BR3 MDB350BR3 MDB400BR4 - MDB500BR4 - -
HEAT PUMP MODELS
OUTDOOR MMC075CR MMC100BR MMC125BR - - MMC75CR x 2 MMC100BR x 2 MMC125BR x 2 MMC100BR x 3 MMC100BR/MMC125BR x 2 MMC100BR x 4 - MMC125BR x 4 - -
kcal/h 18650 24899 30242 - - 37298 49798 60484 74698 84797 99597 - 120968 - -
NOMINAL HEATING CAPACITY W 21688 28957 35170 - - 43376 57913 70340 86870 98623 115826 - 140680 - -
Btu/h 74000 98800 120000 - - 148000 197600 240000 296400 336500 395200 - 480000 - -
kcal/h 18650 24333 29234 - - 37298 48635 58468 72953 83367 97270 - 116935 - -
NOMINAL COOLING CAPACITY

RATED TOTAL POWER CONSUMPTION (HEATING)


W
Btu/h
W
21688
74000
9100
28300
96560
9477
33998
116000
10496
-
-
-
-
-
-
43376
148000
18170
56565
193000
19940
67995
232000
22162
84848
289500
29815
96952
330800
31907
113130
386000
39255
-
-
-
135991
464000
45619
-
-
-
-
-
-
Ducted Split Systems
RATED TOTAL POWER CONSUMPTION (COOLING) W 8500 10219 12168 - - 16970 21424 25506 32041 35993 42223 - 52307 - -
RATED RUNNING CURRENT (HEATING) A 14.5 17.9 21.0 - - 29.6 38.1 42.9 56.8 61.6 75.0 - 87.9 - -
RATED RUNNING CURRENT (COOLING) A 14.2 18.6 22.9 - - 29.0 39.5 46.7 58.9 66.1 77.8 - 95.5 - -

INDOOR MDB075B MDB100B MDB125C MDB150B1 MDB150C1 MDB150B2 MDB200B2 MDB250B2 MDB300B3 MDB350B3 MDB400B4 MDB450B3 MDB500B4 MDB600B4 MDB750B5
COOLING ONLY MODELS
OUTDOOR MMC075C MMC100B MMC125B MMC150C MMC150C MMC75C x 2 MMC100B x 2 MMC125B x 2 MMC100B x 3 MMC100B / MMC125B x 2 MMC100B x 4 MMC150C x 3 MMC125B x 4 MMC150C x 4 MMC150C x 5
kcal/h 18900 25200 31500 37800 37800 37800 50400 63000 75600 88200 100800 113400 126000 151200 189000
NOMINAL COOLING CAPACITY W 21975 29300 36625 43950 43950 43950 58600 73250 87925 102550 117200 131850 146500 175800 219750
Btu/h 75000 100000 125000 150000 150000 150000 200000 250000 300000 350000 400000 450000 500000 600000 750000
RATED TOTAL POWER CONSUMPTION (COOLING) W 8380 10564 11830 16860 16830 16090 21130 25146 31600 35486 41635 53010 51587 73820 91050
RATED RUNNING CURRENT (COOLING) A 18.9 22.0 21.9 29.1 29.5 29.2 39.8 45.4 59.2 64.9 78.2 90.5 92.9 125.4 155.0

REFRIGERANT TYPE R22


FIN MATERIAL ALUMINIUM
TUBE MATERIAL SEAMLESS COPPER
PIPE CONNECTION BRAZING
LIQUID mm (in) 12.70 (1/2) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8) 12.70 (1/2) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8)
PIPE SIZE
GAS mm (in) 25.40 (1) 28.58 (1-1/8) 34.92 (1-3/8) 34.92 (1-3/8) 34.92 (1-3/8) 25.40 (1) 28.58 (1-1/8) 34.92 (1-3/8) 28.58 (1-1/8) 28.58 (1-1/8) / 34.92(1-3/8) 28.58 (1-1/8) 34.92 (1-3/8) 34.92 (1-3/8) 34.92 (1-3/8) 34.92 (1-3/8)

INDOOR
POWER SOURCE V/Ph/Hz 220-240/1/50 380-415/3/50 400/3/50
NOMINAL AIR FLOW cfm / L/s 2500/1180 2800/1132 4200/1982 4600/2171 4600/2171 4600/2171 6400/3021 8000/3776 9000/4248 10500/4956 12000/5664 13500/6372 15000/7080 20000/9440 25000/11800
STATIC PRESSURE mm Aq 15 10 20 15 25 15 15 35 35 35 35 35 40 50 50
FACE AREA m2/ft2 0.54/5.82 0.54/5.82 0.79/8.60 1.00/10.82 0.90/9.80 1.00/10.82 1.20/12.92 1.48/16.01 1.62/17.50 2.38/25.62 2.38/25.62 2.58/27.78 2.55/27.5 3.37/36.3 3.97/42.7
HEIGHT mm/in 572/22.5 572/22.5 736/29.0 885/34.8 736/29.0 885/34.8 945/37.2 1291/50.8 1291/50.8 1546/60.9 1546/60.9 1546/60.9 1546/60.9 1977/77.8 2257/88.9
DIMENSION WIDTH mm/in 1502/59.1 1502/59.13 1640/64.6 1640/64.6 1819/71.6 1640/64.6 1894/74.6 1866/73.5 1866/73.5 2122/83.5 2274/89.5 2274/89.5 2274/89.5 2274/89.5 2274/89.5
DEPTH mm/in 761/30.0 761/20.0 965/38.0 1040/40.9 965/38.0 1040/40.9 980/38.6 1199/47.2 1199/47.2 1199/47.2 1466/57.7 1466/57.7 1466/57.7 1905/75.0 1905/75.0
WEIGHT kg 92 102 171 189 197 189 220 343 343 440 513 564 606 991 1051
ROOM TEMPERATURE MICROCOMPUTER CONTROLLED THERMOSTAT
CONTROL
OPERATION SLM WIRED HANDSET SEQ. LCD WIRED HANDSET
CONDENSATE DRAIN SIZE mm/in 25.4/1
AIR FILTER WASHABLE SARAN NET FIELD SUPPLY
HEIGHT mm/in 762/30.0 762/30.0 930/36.6 1154/45.4 930/36.6 1154/45.4 1154/45.4 1506/59.3 1506/59.3 1766/69.5 1766/69.5 1766/69.5 1766/69.5 1977/77.8 2257/88.9
PACKING DIMENSION WIDTH mm/in 1650/65.0 1650/65.0 1772/69.8 1787/70.4 1901/74.8 1787/70.4 2052/80.8 2034/80.1 2034/80.1 2279/89.7 2431/95.7 2431/95.7 2431/95.7 2174/85.6 2174/85.6
DEPTH mm/in 880/34.6 880/34.6 1047/41.2 1188/46.8 1047/41.2 1188/46.8 1188/46.8 1412/55.6 1412/55.6 1412/55.6 1684/66.3 1684/66.3 1684/66.3 1905/75.0 1905/75.0

OUTDOOR
POWER SOURCE V/Ph/Hz 380-415/3/50
COMPRESSOR TYPE SCROLL
LOCK ROTOR AMP. A 95 125 110 198 198 95 125 110 125 125/110 x 2 125 198 110 198 198
PROTECTION DEVICE OVERLOAD PROTECTION WITH AUTO RESET HI/LO PRESSURE SWITCH (FOR MMC 150C ONLY : CONTROL MODULE & AUTO RESET HI/LO PRESSURE SWITCH)
FAN TYPE/DRIVE PROPELLER/DIRECT
BLADE MATERIAL ALUMINIUM
HEIGHT mm/in 946/37.2 946/37.2 946/37.2 1041/41.0 1041/41.0 946/37.2 946/37.2 946/37.2 946/37.2 946/37.2 / 946/37.2 946/37.2 1041/41.0 946/37.2 1041/41.0 1041/41.0
DIMENSION WIDTH mm/in 1300/51.2 1116/43.9 1116/43.9 1116/43.9 1116/43.9 1300/51.2 1116/43.9 1116/43.9 1116/43.9 1116/43.9 / 1116/43.9 1116/43.9 1116/43.9 1116/43.9 1116/43.9 1116/43.9
DEPTH mm/in 500/19.7 939/37.0 939/37.0 939/37.0 939/37.0 500/19.7 939/37.0 939/37.0 939/37.0 939/37.0 / 939/37.0 939/37.0 939/37.0 939/37.0 939/37.0 939/36.7
WEIGHT kg 145 164 169 227 227 145 164 169 164 164/169 164 227 169 227 227
MATERIAL ELECTRO GALVANISED MILD STEEL
CASING
FINISHING EPOXY POLYESTER POWDER
HEIGHT mm/in 1132/44.6 1132/44.6 1132/44.6 1227/48.3 1227/48.3 1132/44.6 1132/44.6 1132/44.6 1132/44.6 1227/48.3 1132/44.6 1227/48.3 1227/48.3
PACKING DIMENSION WIDTH mm/in 1414/55.7 1282/50.5 1282/50.5 1282/50.5 1282/50.5 1414/55.7 1282/50.5 1282/50.5 1282/50.5 1282/50.5 1282/50.5 1282/50.5 1282/50.5
DEPTH mm/in 664/26.1 1112/43.8 1112/43.8 1112/43.8 1112/43.8 664/26.1 1112/43.8 1112/43.8 1112/43.8 1112/43.8 1112/43.8 1112/43.8 1112/43.8

1) ALL SPECIFICATIONS ARE SUBJECT TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE
Outdoor Units: 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ARI 210/240-94
3) NOMINAL COOLING AND HEATING CAPACITIES ARE BASED ON THE FOLLOWING CONDITIONS:
a) COOLING - 26.7˚C DB/19.4˚C WB INDOOR AND 35.1˚C OUTDOOR
b) HEATING - 21.1˚C DB/15.6˚C WB INDOOR AND 8.3˚C DB/6.1˚C WB OUTDOOR
4) ALLOWABLE OPERATING RANGE:
a) COOLING - 19.4˚C DB/13.9˚C WB INDOOR, AND 19.4˚C DB OUTDOOR TO
26.7˚C DB/19.4˚C WB INDOOR, AND 46.1˚C DB OUTDOOR
b) HEATING - 21.1˚C DB INDOOR, AND -8.3˚C DB/-9.4˚C WB OUTDOOR TO
26.7˚C DB INDOOR, AND 23.9˚C DB/18.3˚C WB OUTDOOR

REGISTERED

MMC 075 C/CR **MMC 100/125 B/BR


MMC 150C ISO 9002

©2002 McQuay International +1 (800) 432-1342 www.mcquay.com


** Unit come with standard vertical air discharge
configuration and convertible for horizontal air discharge application.
Indoor Units

r Climate,
You We'r
e There

MDB 075/100 B/BR

FEATURES

Evergreen
This unit is installed above the Scroll Compressor
ceiling with only supply and return MDB 125 C/CR
grille exposed to view, this has made
Quiet Air Flow
it an "Evergreen" design. Fresh Air Copeland
Compliant® Scrolls
BHD
SDN
ABC

Flexibility In Installation High Efficiency


The supply and return grille can be selected
based on end user or professional interior
designer in integrating the MDB unit to their Fresh Air For Healthy Living High Reliability High Efficiency
Motor
favorite interior design. Fresh air can be introduced into the building through
The range from MDB150 B/BR to 500 B4/BR4 are the design of fresh air intakes. This will improve the
designed to cater for either horizontal or vertical indoor air quality. Quiet Operation MDB 150 B1
air discharge application. Quiet Shutdown
Device
MDB 150/200/250 B2/BR2
MD 300/350 B3/BR3
Vertical Blow
Superior Air Distribution For
Comfortable Living MDB 400/500 B4/BR4
The conditioned air can be effectively distributed
Sequential Controller For Models
* MDB 150 B2 To MDB 500B4
to every corner of the room through the ducting MDB 150 BR2 To MDB 500 BR4
Horizontal
Blow and this ensure a more pleasant environment for
comfort living.
This is a multi purpose controller that provides
Return Air
the following features:
a Sequential control and balance loading up to
4 compressor.
b Optional operation mode, available selection are
"Heat/Cool/Auto/Fan" mode.
c 2 stages Auxiliary electric heater MDB 600 B4 / 750 B5
Versatility
d Wired LCD control with 7 days programmable timer.
Multiple rooms can be cooled together at the same
e Self diagnostic functions. SLM Wired Controller
time by using just one unit of fan coil. *For MDB 075/100 B/BR
f Alternative outdoor defrost cycle. MDB 125 C/CR
g Auto random restart option - memory backup.