Professional Documents
Culture Documents
pdf
Journal of Dairy Research (2001) 68 417±427. Printed in the United Kingdom 417
Development and application of confocal scanning laser
microscopy methods for studying the distribution of fat and protein
in selected dairy products
By MARK A. E. AUTY"*, MYRA TWOMEY", TIMOTHY P. GUINEE"
and DANIEL M. MULVIHILL#
Rheology of milk chocolate
Samples of each chocolate were taken at the end of the conching stage and
rheological properties were measured at 40 °C using a stress-controlled rheometer as
described by Twomey et al. 2000. Casson yield value and Casson viscosity were
calculated using the Casson equation (OICC, 1973).
Engman_02.pdf
Mulji_01.pdf
0960–3085/03/$23.50+0.00
# Institution of Chemical Engineers
www.ingentaselect.com=titles=09603085.htm Trans IChemE, Vol 81, Part C, June 2003
A Davenport capillary rheometer was used to make extrudates for the cube compression tests, at
20°C. It is a constant-velocity, vertical, batch extruder. Extrudates were produced using an aluminium
square exit die (7x7 mm) with a land length of 10mm and a processing rate of 0.785cm 3 s-1. The
extrudates were then immediately cut to a length of 7mm using a blade.
Kilcast_01.pdf
Rheological measurements were made using a CarriMed controlled stress rheometer (model
CSL2100, TA Instruments, Leatherhead, UK). A sample was loaded onto the plate of the rheometer
and oil was applied around the boundary of the cone to prevent sample evaporation. Measurements on
the model systems and artificial creams were carried out at both 5 and 37 °C to assess any differences
between serving and body temperature. Measurements on the chocolate mousses were carried out at
20 °C. Firmness of the chocolate mousses was measured at 5 °C using a Stable Micro Systems
TAXT2 Texture Analyser (Stable Micro Systems, Godalming, UK), using a 35-mm diameter
cylindrical probe set to penetrate to a depth of 8 mm at a rate of 1 mm/s and then return to the start
point, again at a rate of 1 mm/s. Results were averaged over three replicate measurements.
Particle size analysis of the model particle systems and determination of the oil droplet size
distribution in the artificial creams were performed using a Malvern Mastersizer
(Malvern Instruments Ltd, Malvern, UK). The air bubble size of the chocolate mousses was measured
using an Optimas Image Analysis System (Optimas Corporation, Washington, USA). Images obtained
from light and confocal microscopy were analysed to obtain the required bubble size information.
Liang_01.pdf
Melt rheology
Rheological properties of the chocolate mass at 40°C were characterized by use of a Brookfield DV-1
HATD viscometer (Stoughton, MA) with a small sample adapter (SC4-13R) and spindle (SC4-21),
according to the international guidelines (Office International du Cocao et du Chocolat, 1973). The
chocolate mass was stabilized for 10 min in the temperaturecontrolled cup and presheared at 20 RPM
for 5 min prior to measurement. Ascending (0.5 to 100 rpm) and descending (100 to 0.5 rpm) tests
were performed for each sample. Torque readings at each shear rate were recorded after 30 s of
shearing for duplicate samples.
The data were analyzed according to the modified Casson model of fluid rheology (Steiner, 1958)
where τ is shear stress (obtained from torque data) and γ is shear rate (obtained from rpm data). The
two parameters used to fit the Casson model are τc, the Casson yield value, and ηc, the Casson plastic
viscosity.
Sokmen_01.pdf
Casson plastic viscosity and Casson yield values were calculated from interpolation data using
Thermo Haake RheoWin Pro 297 Software by the least squares method. Other rheological
parameters (yield stress, apparent viscosity and thixotropy) were deduced from data as
recommended by ICA (2000) and Servais et al. (2004) with some modifications. Value of stress at a
shear rate of 5 s-1 represented yield stress, viscosity ata shear of 30 s -1, apparent viscosity, and
difference between yield stresses at 5 s-1 during ramp up and down, thixotropy.
Afoakwa_05.pdf
Effects of particle size distribution and composition
on rheological properties of dark chocolate
Emmanuel Ohene Afoakwa Æ Alistair Paterson Æ
Mark Fowler
Rheological measurements
The rheological behavior of molten dark chocolate was characterized using steady shear
measurements. All measurements were carried out in shear rate-controlled rheometer (Thermo Haake
ViscoTester 550 (VT 550), Thermo Electron Corp., Karlsruhe, Germany) using bob and cup
(Recessed end) geometry (Sensor SVI and SVII), as for IOCCC method [22] with a ratio of inner to
outer radius of 0.92 in the concentric cylinder system. Samples were incubated at 50 °C for 75 min for
melting and transferred, pre-sheared at 5 s–1 rate for 15 min at 40 °C, before measurement cycles.
Shear stress was measured at 40 °C as function of increasing shear rate from 5 to 50 s–1 (ramp up)
within 120 s, then decreasing from 50 to 5 s–1 (ramp down), within each ramp 50 measurements were
taken. Temperature of the chocolates samples was controlled during the experiment using Haake K20
Thermo-regulator (Thermo Electron Corp., Karlsruhe, Germany), and solvent trap was used to
prevent water evaporation. Mean value and standard deviation of triplicate readings were recorded.
The Casson model was used to calculate Casson plastic viscosity and Casson yield values from
interpolation data using ThermoHaake RheoWin Pro 297 Software by the least square method.
The Casson model equation is denoted by:
Other rheological parameters (yield stress, apparent viscosity and thixotropy) were deduced from data
as recommended by ICA [8] and Servais et al. [3] with some modifications. Value of stress at a shear
rate of 5 s–1 represented yield stress, viscosity at a shear of 30 s–1, apparent viscosity; and difference
between yield stress at 5 s–1 during ramp up and down, thixotropy.