You are on page 1of 4

Trivector Meter

-ER300P
FEATURES
0.2S / 0.5S / 1.0 Class accuracy
l Configurable Load survey recorders
l

Multi Tariff Capability with


l Back lit LCD display
l

programmable TOD 3 Display modes for easy data access


l

3 Programmable Maximum
l Support of Phasor viewing on MRI
l

demand (MD) registers Battery back-up for Data collection


l

Tamper / failure detection and record capability


l Periodic self diagnostic checks
l

Communication interface via Optical


l

port conforming to IEC 1107 protocol.

TECHNICAL SPECIFICATIONS
Accuracy Class 1.0 - IEC 1036 / IS 13779
Class 0.5S / 0.2S - IEC 687 / CBIP 88

Voltage (Vn) 3Ph 4W - 415 V AC (-40% to +20%)


110 V AC (-40% to +20%)
3Ph 3W - 110 V AC (-40% to +20%)

Current (In) 5 A or 1 A (to 200%)

Starting current 0.2% In (Class 1.0)


0.1% In (Class 0.5S / 0.2S)

Power factor 4 quadrant operation

Frequency 50 Hz ±10%

Load characteristics < 5 VA in potential circuit


< 0.5 VA in current circuit

Field configurable features Meter configuration - Uni or Bi-directional


Method of kvah calculation - Lead as lead
- or Lead as UPF
External CT / PT ratios
MD settings - Max. 3 out of 8 parameters
TOD settings
Reset modes - Manual, Auto monthly,
Auto daily, Auto monthly and manual.
Load survey settings - No. of days and parameters.
Real Time Clock setting
3 Display modes Mode 1 / 2 / 3

Electromagnetic compatibility IEC 1036 / IS 13779 (Class 1.0)


IEC 687 / CBIP - 88 (Class 0.5S / 0.2S)

Case material Plastic molded with transparent cover Protected to -


IP 51 - IEC 1036 / IS 13779 (Class 1.0)
IP 51 - IEC 687 / CBIP - 88 (Class 0.5S / 0.2S)

Insulation properties & IEC 1036 / IS 13779 ( Class 1.0)


HV insulation resistance IEC 687 / CBIP - 88 ( Class 0.5S / 0.2S)

Temperature -50C to 600C for operation


-200C to 700C for storage

Humidity 95% RH Condensing

Dimension 320 L x 175 W x 110 H

Weight < 2.5 Kgs


INTRODUCTION MAXIMUM DEMAND (MD) RESET
Electronic Trivector meter, REGISTERS Meter can be configured for one of
ER300P - PRIDE is a multi- 3 MDs out of 8 energy types can the reset modes such as Manual
purpose unit which integrate be selected and programmed for reset, Auto monthly reset, Auto
several functions and replace separate integration period daily reset, Auto monthly &
various equipments for metering ranging from 1 minute to 60 manual reset. 12 reset backups
energy parameters. It is light, minutes. MD1 can be configured are provided.
compact and highly reliable. for Block / Sliding window method.
L&T has indigenously designed Reset MD (12 readings) and TIME-OF-DAY (TOD)
and developed the same at its cumulative MD are also available. The meter offers a flexible tariff
state-of-the-art manufacturing structure. During different times of
facility at Mysore. It is well suited LOAD SURVEY the day for different seasons,
for Indian transmission and different tariff structure can be
RECORDERS
distribution network and can be programmed. A real time clock
Registers for load survey data
used for uni directional or bi- with a lithium battery has a built-in
record upto 4 energy parameters.
d i r e c t i o n a l m e t e r i n g , TO D 100 years calendar. It is used for
The integration period and
metering, and for energy time keeping. A day can be
number of days are
management. It is available for divided into 10 defined slots (11
programmable.
both HT and LT applications. undefined slots). Upto 8 tariffs
registers programmable.
TAMPER / FAILURE Supports upto 4 profiles, 4
DISPLAY PARAMETERS
RECORDING seasons and 4 special days.
Meter can be programmed to
Meter detects and records various
display maximum 350 parameters
tamper / failure conditions such as
that include PF, per phase RMS LED PULSE OUTPUT
voltage failure, current failure,
voltages and currents, Frequency, ER300P incorporates two LEDs
voltage unbalance, current
Phase sequence, real time clock, on the front panel of the meter for
unbalance, current bypass,
kW, kVA, kVAr, kWH, kVAh, accuracy check of kWh and
current reversal and power
kVArh+, kVArh-, MDs’, Rising kVArh.
failure. For above conditions,
demand with elapsed time, high
Ta m p e r c o u n t , D u r a t i o n ,
resolution energies, tamper
Occurrence date / time and BATTERY OPERATION
details, etc.
present status is recorded by A Push button on the front panel
sequence storage or Block enables data collection, viewing
DISPLAY MODES storage method. data on LCD and resetting data
Three display modes Mode1, during power failure.
Mode2 and Mode3 are available.
CONTROL KEYS
Two control keys are located on COMMUNICATION
KVAh / MD kVA the front panel of the mete for INTERFACE
CALCULATION METHODS manual scrolling mode, various ER300P incorporates an infra-red
Method of kVAh / MD kVA display parameters can be optical port6 interface on the front
calculation can be configured for displayed using the same. Manual panel as per IEC 1107 standard.
lead to be treated as upf or lead to reset can be performed from key An optical port and a standard
be treated as lead itself. on front panel. RS232C port on the PC/MRI side.

BILLING REGISTERS
8 billing registers are available for
recording 8 type of energies -
kWH, kVAh, kVArh+, kVArh- (both
forward / reverse). The last 12
readings for record / analysis.
Average PF for each reset is
available.
DIMENSIONAL DETAILS OF
TRIVECTOR METER (BASE MOUNTING)

171

3xO6
97

255
78.75
303

157.5
181

6
25
CUTOUT

150

Ahmedabad Tel : (079)66304007 Fax : (079)26580491 Hyderabad Tel : (040)23296468 Fax : (040)23242356
Bangalore Tel : (080)25583613 Fax : (080)25580525 Kolkata Tel : (033)44002301 Fax : (033)22821025
Chandigarh Tel : (0172)4646841 Fax : (0172)4646802 Mumbai Tel : (022)67050505 Fax : (022)67051112
Chennai Tel : (044)28462072 Fax : (044)28462102 New Delhi Tel : (011)51419515 Fax : (011)51419600
Pune Tel : (020)66033395 Fax : (020)26129586

Electrical Standard Products


Larsen & Toubro Limited
Powai Campus, Mumbai 400 072
Tel: 022-6705 0505
Fax: 022-67051324 / 1746
E-mail: esp@LNTEBG.com
Website: www.LNTEBG.com

SP 50301(D1) 250507

You might also like