APPARATUS : Dial gage, fixed support, load meter, beam specimen, Mild Steel beam,
Brass beam, Aluminum beam, Vernier caliper, ruler, and load.
DIAGRAM :
R 2 = ( R y ) ( L / 2)
2 2
= R 2 2 y y 2 L2 / 4
Hence,
2 Ry L2 / 4
R L2 / 8 y
E M
Where, M = W(x)
R I
bh 3
I=
12
E.8 y W ( x)
Therefore;
L2 I
( E.I .8) y
W
L2 ( x )
PROCEDURE :
EXPERIMENTAL RESULTS:
CALCULATIONS:
i. Mild Steel
18
16
14
12
Load (N)
10
8
6
4
2
0
0 0.5 1 1.5 2 2.5
Beam max. deflection (mm)
4.54mm
1000mm 20.4mm
3
bh (0.0204)(4.54 10 3 ) 3
I
12 12
= 1.591 10 10 m 4
W .L2 ( x)
E
I .8. y
= 251.8 GPa
Average value for E = (251.8+ 247.6+ 240.2+ 240.0+ 239.1+ 237.6+ 236.5 + 237.1) GPa
8
= 241 GPa
ii. Aluminum
18
16
14
12
Load (N)
10
8
6
4
2
0
0 0.5 1 1.5 2 2.5
Beam max. deflection (mm)
6.0mm
1000mm 20.0mm
3
bh (0.02)(6.0 10 3 ) 3
I
12 12
= 3.6 10 10 m 4
W .L2 ( x)
E
I .8. y
= 118.4 GPa
Average E = (118.4 + 108.1 + 109.3 + 111.5 + 108.9 + 105.7 + 107.1 + 108.7) GPa
8
= 110 GPa
iii. Brass
18
16
14
12
Load (N)
10
8
6
4
2
0
0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6
Beam max. deflection (mm)
6.6mm
1000mm 21.8mm
3
bh (0.0218)(6.6 10 3 ) 3
I
12 12
= 5.222 10 10 m 4
W .L2 ( x)
E
I .8. y
= 123.8 GPa
Average E = (123.8 + 115.1 + 113.1 + 111.3 + 108.9 + 108.4 + 107.4 + 107.3) GPa
8
= 112 GPa
DISCUSSION:
When the experiment have be done, the value of Modulus of Elasticity, E for each
beam is calculated. Since, there are distinction values of experiment by compared
to theoretical values. Comparing values is described below:
Mild Steel
E ( Theory) = 210 GPa
E ( Experiment) = 241 GPa
Percentage of error is given by,
E (Theory ) E ( Exp)
% Error
E (Theory )
Aluminum
E ( Theory) = 70 GPa
E ( Experiment) = 110 GPa
Brass
E ( Theory) = 104.1 GPa
E ( Experiment) = 112 GPa
E (Theory ) E ( Exp)
% Error
E (Theory )
Some of the errors appear while running the experiment. They could be the
inefficiency of the apparatus or slightly human errors. As for the apparatus, it has
been used for many repeated times and may experienced wear thus affected the
accuracy. For example, the dial gage is not consistent when the load was applied.
If the experiment repeat once again as same load, it showed a different readings.
This means that, the dial gages is not reliable in order to measure the readings.
The specimens also experience wear same as the dial gauge because its have been
used many times before this experiment is conducted. When the specimens is
measured by 1 meter ruler it is not straight as the 1 meter ruler.
One more precautions that could be useful to reduce the errors is when placing the
load. The experimenter must place it slowly and tend not to release it so hard as
the dial gages were so sensitive and may detect more loads that it supposed to be.
Besides, the errors may comes from the distance of x. There may have little
difference distance of x at right and left sides. It can cause the loaded was not
balance accurately.
CONCLUSION:
By using the method of deflection, we obtain that the values of elastic modulus is:
E (mild steel) = 241 GPa
E (aluminum) = 110 GPa
E (brass) = 112 GPa
REFERENCES: