Enabling HP OpenView Storage Data Protector client agents on

Microsoft Windows 2003 x86-64 platform white paper

Introduction......................................................................................................................................... 2
Executive summary............................................................................................................................... 2
Installation procedure ........................................................................................................................... 2
1. Preparing the Cell Server/Manager before importing the Microsoft Windows 2003 x86-64 client............ 3
1.1. Instructions for installing SSPNT550_119 for Windows Cell Server................................................. 3
1.2. Instructions for installing SSPSOL550_033 for Solaris Cell Server ................................................... 4
1.3. Instructions for installing SSPUX550_122 for HP-UX PA-RISC Cell Server.......................................... 6
1.4. Instructions for installing SSPUX550_129 for HP-UX Itanium Cell Server........................................... 8
2. Preparing the Storage Data Protector Cell Console (CC) Systems before importing the Microsoft Windows
2003 x86-64 client.............................................................................................................................. 9
2.1. Instructions for installing SSPNT550_119 for Windows CC System................................................. 9
2.2. Instructions for installing SSPSOL550_033 for Solaris DP CC System ............................................ 10
2.3. Instructions for installing SSPUX550_122 for HP-UX DP CC System ............................................... 12
3. Installing the core and agent patches for Microsoft Windows 2003 x86-64 support .............................. 14
3.1. Instructions for installing Agent Core SSP (SSPNT550_111) ......................................................... 14
Installation of the agents ..................................................................................................................... 15
3.2. Installation instructions for Disk Agent (SSPNT550_118) .............................................................. 15
3.3. Installation instructions for Media Agent (SSPNT550_130)........................................................... 16
3.4. Installation instructions for SMISA Agent (SSPNT550_100) .......................................................... 17
3.5. Installation instructions for SQL Agent (SSPNT550_131) .............................................................. 18
3.6. Installation instructions for SAP Agent (SSPNT550_126) .............................................................. 19
3.7. Installation instructions for XP/SSEA Agent (SSPNT550_102)....................................................... 20
3.8. Installation instructions for MAXDB Integration Agent (SSPNT550_135)......................................... 21
3.9. Installation instructions for future Storage Data Protector integration agent patches ......................... 21
For more information.......................................................................................................................... 22
Introduction
The support of HP OpenView Storage Data Protector on Microsoft® Windows® 2003 x86-64
needed a port of Storage Data Protector agents in native 64-bit mode. The support of different agents
has been released in site-specific patches (SSPs).
The following SSPs have been released:
• SSPNT550_111—Core
• SSPNT550_118—Disk Agent
• SSPNT550_130—Media Agent
• SSPNT550_131—SQL Integration Agent
• SSPNT550_100—SMISA Integration Agent
• SSPNT550_126—SAP Integration Agent
• SSPNT550_102—XP/SSEA Agent
• SSPNT550_135—MAXDB Integration Agent

The following SSP is scheduled to be released in the near future to support the following agent:
• SSPNT550_136—Oracle Integration Agent

Note:
Initial earlier releases of SSPNT550_072 (Media Agent), SSPNT550_087
(Disk Agent), and SSPNT550_101 (SQL Integration Agent) have been
recalled as these patches were not working together, causing functional
problems.

Executive summary
The procedure to install the preceding SSPs and all their prerequisites is complex and a consolidated
documentation for installation is needed.
Therefore, this white paper describes the preparation of the Cell Manager and Cell Console systems
and then explains, one by one, the installation of the preceding SSPs for Microsoft Windows 2003
x86-64 agents.

Installation procedure
The following sections detail the step-by-step instructions for installing Storage Data Protector clients on
the Microsoft Windows 2003 x86-64 platform. The recommendation is to follow these instructions
rather than following the readme.txt, which is packaged along with the SSPs. This holds true for all
the released SSPs unless the reader is explicitly asked to refer for the readme.txt in some cases.

Note:
In case an agent mentioned in the following instruction sections is not
needed in your environment, skip the section corresponding to that agent.

2
Notations followed for applying the SSPs:
• <Target System> refers to Microsoft Windows x86-64 client system.
• <Program files Home> refers typically to C:\Program Files.
• <Program files x86 Home> refers typically to C:\Program Files (x86).
• <OMNIHOME> refers typically to C:\Program Files\OmniBack for Windows, and /opt/omni for
Solaris and HP-UX.

1. Preparing the Cell Server/Manager before importing the


Microsoft Windows 2003 x86-64 client
• As a prerequisite, install the latest Data Protector Cell Server, Core, and Cell Console general
release patches.

Note:
The following installation instructions in steps 3and 4 mention the names of
the general release patches that are actually at the time when this paper is
released.

• Install the appropriate SSP on the Cell Manager system, depending on its operating system
platform:
– SSPNT550_119 for Windows Cell Manager
– SSPSOL550_033 for Solaris Cell Manager
– SSPUX550_122 for HP-UX PA-RISC Cell Manager
– SSPUX550_129 for HP-UX Itanium Cell Manager

1.1. Instructions for installing SSPNT550_119 for Windows Cell Server


The patch SSPNT550_119.exe contains:
• Users.dll
• Restore.dll
• Report.dll
• Mom.exe
• Manager.exe
• instrest.dll
• Monitor.dll
• DataBase.dll
• Copy.dll
• Clients.dll
• Backup.dll
• Admin.dll
• Core.dll
• bsm.exe

3
1. Log on to the Windows Cell Server System where you want to apply this patch.
2. Close all Storage Data Protector sessions. Stop Data Protector OmniInet and all other Storage Data
Protector Services by executing omnisv -stop from command prompt.
3. As a prerequisite, install the GR Patches DPWIN_00192(CS), DPWIN_00202(Core), and
DPWIN_00191(CC) as per the installation instructions in these patches on the Windows Cell
Server System, if they are not already installed.
4. Execute this self-extracting SSP to unpack the binaries provided in it into some temporary folder in
the Windows Cell Server System, referred to as “Extraction Folder” henceforth.
5. Keep a copy of the following original binaries in some other location in the Windows Cell Server
System.
6. Copy the following binaries from the “Extraction Folder” into <OMNIHOME>\bin in the Windows
Cell Server System:
o Users.dll
o Restore.dll
o Report.dll
o Mom.exe
o Manager.exe
o instrest.dll
o Monitor.dll
o DataBase.dll
o Copy.dll
o Clients.dll
o Backup.dll
o Admin.dll
o Core.dll
o bsm.exe

7. Re-start all the Storage Data Protector processes in the Windows Cell Server System by executing
omnisv -start from command prompt.

1.2. Instructions for installing SSPSOL550_033 for Solaris Cell Server


The patch SSPSOL550_033.exe contains:
• libadmin.so
• libbackup.so
• libclients.so
• libcopy.so
• libcore.so
• libdatabase.so
• libinstrest.so
• libmonitor.so
• libreport.so
• librestore.so
• libusers.so
• xomni_manager
• xomni_mom

4
• bsm
• rsm
• csm
• Install_SSPSOL550_033.sh
• SSPSOL550_033.txt

1. Log on to the Solaris Cell Server System where you want to apply this patch.
2. As a prerequisite, install the Patches DPSOL_00200(CS), DPSOL_00207(Core), and
DPSOL_00199(CC) as per the installation instructions in these patches on the Solaris Cell Server
System.
3. Close all Storage Data Protector sessions. Stop Storage Data Protector OmniInet and all other
Storage Data Protector Services by executing <OMNIHOME>/sbin/omnisv -stop in the Solaris
Cell Server System.
4. Unshar the binaries provided in this SSP SSPSOL550_033 into a temporary directory in the Solaris
Cell Server System, referred to as ”Extraction Directory” henceforth, by executing following from
the command prompt: # sh SSPSOL550_033.shar
A directory SSPSOL550_033 will be created under the <Extraction Directory> in the Solaris Cell
Server System and the following files will be placed in the directory <Extraction
Directory>/SSPSOL550_033/ after execution of the preceding command:
o libadmin.so
o libbackup.so
o libclients.so
o libcopy.so
o libcore.so
o libdatabase.so
o libinstrest.so
o libmonitor.so
o libreport.so
o librestore.so
o libusers.so
o xomni_manager
o xomni_mom
o bsm
o rsm
o csm
o Install_SSPSOL550_033.sh
o SSPSOL550_033.txt

5. Run the script Install_SSPSOL550_033.sh from the command prompt in the Solaris Cell Server
System by executing the following commands:
o # cd <Extraction Directory>/SSPSOL550_033
o # chmod +x Install_SSPSOL550_033.sh
o # ./Install_SSPSOL550_033.sh

5
The script Install_SSPSOL550_033.sh will save a copy of the original binaries listed later as
“<origFileName>.bak.” Then, this script will copy the necessary following binaries from
<Extraction Directory>/SSPSOL550_033 to following locations:
To <OMNIHOME>/gui/bin/:
o libadmin.so
o libbackup.so
o libclients.so
o libcopy.so
o libcore.so
o libdatabase.so
o libinstrest.so
o libmonitor.so
o libreport.so
o librestore.so
o libusers.so
o xomni_manager
o xomni_mom

To the directory <OMNIHOME>/lbin/:


o bsm
o rsm
o csm

Then, the script Install_SSPSOL550_033.sh will restart the Storage Data Protector Services like
mmd, crs, and rds in the Solaris Cell Server System.

1.3. Instructions for installing SSPUX550_122 for HP-UX PA-RISC Cell


Server
The patch SSPUX550_122.exe contains:
• libadmin.sl
• libbackup.sl
• libclients.sl
• libcopy.sl
• libcore.sl
• libdatabase.sl
• libinstrest.sl
• libmonitor.sl
• libreport.sl
• librestore.sl
• libusers.sl
• xomni_manager
• xomni_mom
• bsm
• rsm

6
• csm
• Install_SSPUX550_122.sh
• SSPUX550_122.txt

1. Log on to the HP-UX PA-RISC Cell Server System where you want to apply this patch.
2. As a prerequisite, install the Patches PHSS_34332(CS), PHSS_34497(Core), and
PHSS_34330(CC) as per the installation instructions in these patches on the HP-UX PA-RISC Cell
Server System.
3. Close all Storage Data Protector sessions. Stop all the Storage Data Protector Services by
executing <OMNIHOME>/sbin/omnisv -stop in the HP-UX PA-RISC Cell Server System.
4. Unshar the binaries provided in this SSP SSPUX550_122 into a temporary directory in the HP-UX
PA-RISC Cell Server System, referred to as “Extraction Directory” henceforth, by executing
following from the command prompt: # sh SSPUX550_122.shar
A directory SSPUX550_122 will be created under the <Extraction Directory> in the HP-UX Cell
Server System and the following files will be placed in the directory <Extraction
Directory>/SSPUX550_122/ after execution of the preceding command:
o libadmin.sl
o libbackup.sl
o libclients.sl
o libcopy.sl
o libcore.sl
o libdatabase.sl
o libinstrest.sl
o libmonitor.sl
o libreport.sl
o librestore.sl
o libusers.sl
o xomni_manager
o xomni_mom
o bsm
o rsm
o csm
o Install_SSPUX550_122.sh
o SSPUX550_122.txt

5. Run the script Install_SSPUX550_122.sh from the command prompt in the HP-UX PA-RISC Cell
Server System by executing the following commands:
o # cd <Extraction Directory>/SSPUX550_122
o # chmod +x Install_ SSPUX550_122.sh
o # ./Install_ SSPUX550_122.sh

The script Install_ SSPUX550_122.sh will save a copy of the original binaries listed later as
“<origFileName>.bak.” Then the script will copy the following necessary files from <Extraction
Directory>/SSPUX550_122 directory to:
To <OMNIHOME>/gui/bin/:
o libadmin.sl
o libbackup.sl

7
o libclients.sl
o libcopy.sl
o libcore.sl
o libdatabase.sl
o libinstrest.sl
o libmonitor.sl
o libreport.sl
o librestore.sl
o libusers.sl
o xomni_manager
o xomni_mom

To <OMNIHOME>/lbin:
o bsm
o rsm
o csm

Then, the script Install_SSPUX550_122.sh will restart the Storage Data Protector Services like
mmd, crs, and rds in the HP-UX PA-RISC Cell Server System.

1.4. Instructions for installing SSPUX550_129 for HP-UX Itanium Cell


Server
The patch SSPUX550_129.exe contains:
• bsm
• rsm
• csm
• SSPUX550_129.txt

1. Log on to the HP-UX Itanium Cell Server System where you want to apply this patch.
2. As a prerequisite, install the Patches PHSS_34333(CS), PHSS_34498 (Core), and
PHSS_34331(CC) as per the installation instructions in these patches on the HP-UX Itanium Cell
Server System.
3. Close all Storage Data Protector sessions. Stop all Storage Data Protector Services by executing
<OMNIHOME>/sbin/omnisv -stop in the HP-UX Itanium Cell Server System.
4. Unshar the binaries provided in this SSP SSPUX550_129 into a temporary directory in the HP-UX
Itanium Cell Server System, referred to as “Extraction Directory” henceforth, by executing following
from the command prompt: # sh SSPUX550_129.shar
A directory SSPUX550_129 will be created under the <Extraction Directory> in the HP-UX Itanium
Cell Server System and the following files will be placed in the directory <Extraction
Directory>/SSPUX550_129/ after execution of the preceding command:
o bsm
o rsm
o csm
o SSPUX550_129.txt

8
5. Make copies of the following original binaries in the HP-UX Itanium Cell Server System. Copy the
following binaries from the directory <Extraction Directory>/ SSPUX550_129/ to the directory
<OMNIHOME>/lbin in the HP-UX Itanium Cell Server System:
o bsm
o rsm
o csm

6. Re-start the Storage Data Protector Services in the HP-UX Itanium Cell Server System by executing
from the command prompt: <OMNIHOME>/sbin/omnisv –start

2. Preparing the Storage Data Protector Cell Console (CC)


Systems before importing the Microsoft Windows 2003
x86-64 client
To later import the Storage Data Protector clients on Microsoft Windows 2003 x86-64 into your cell
after you installed them, you must now on your Cell Console apply the respective SSP from the
following list. Note that a Microsoft Windows 2003 x86-64 system cannot be a CC client itself
because the GUI functionality was not ported to x86-64.
• Install latest Storage Data Protector Cell Console (CC) patches.
• Install the appropriate SSP on the Storage Data Protector CC System:
– SSPNT550_119 for Microsoft Windows i386 32bit CC System
– SSPSOL550_033 for Solaris CC System
– SSPUX550_122 for HP-UX PA-RISC CC System

2.1. Instructions for installing SSPNT550_119 for Windows CC System


The patch SSPNT550_119.exe contains:
• Users.dll
• Restore.dll
• Report.dll
• Mom.exe
• Manager.exe
• instrest.dll
• Monitor.dll
• DataBase.dll
• Copy.dll
• Clients.dll
• Backup.dll
• Admin.dll
• Core.dll
• bsm.exe

1. Log on to the Windows Storage Data Protector CC System where you want to apply this patch.
2. Be sure that you have applied the latest CC general release patch to the system, that is,
DPWIN_00191 or one of its successors.

9
3. Close all Storage Data Protector UI and other Storage Data Protector sessions. Stop Storage Data
Protector OmniInet Service by selecting Data Protector Inet service from the list of services from
Start, Settings, Control Panel, Administrative Tools, Services, then right-clicking and selecting Stop
in the Windows DP GUI System.
4. Execute the self-extracting SSPNT550_119.exe to unpack the binaries provided in it into some
temporary location, referred to as “Extraction Folder” henceforth in the Windows DP CC System.
5. Keep a copy of the following original binaries in some other location in the Windows DP CC
System.
Copy the following binaries from the “Extraction Folder: into:
<OMNIHOME>\bin in the Windows DP CC System:
o Users.dll
o Restore.dll
o Report.dll
o Mom.exe
o Manager.exe
o instrest.dll
o Monitor.dll
o DataBase.dll
o Copy.dll
o Clients.dll
o Backup.dll
o Admin.dll
o Core.dll

6. Re-start the DP OmniInet service in the Windows DP CC System by selecting “Data Protector Inet”
service from the list of services from Start, Settings, Control Panel, Administrative Tools, Services,
then right-clicking and selecting Start. Re-start the DP GUI in the Windows DP CC System.

2.2. Instructions for installing SSPSOL550_033 for Solaris DP CC


System
The patch SSPSOL550_033.exe contains:
• libadmin.so
• libbackup.so
• libclients.so
• libcopy.so
• libcore.so
• libdatabase.so
• libinstrest.so
• libmonitor.so
• libreport.so
• librestore.so
• libusers.so
• xomni_manager
• xomni_mom

10
• bsm
• rsm
• csm
• Install_SSPSOL550_033.sh
• SSPSOL550_033.txt

1. Log on to the Solaris DP CC System where you want to apply this patch.
2. Be sure that you have applied the latest Core and CC general release patches to the Solaris DP
CC System. These patches are DPSOL_00207 (Core) and DPSOL_00199 (CC) or one of their
respective successors.
3. Close all Storage Data Protector UI sessions in the Solaris DP CC System.
4. Unshar the binaries provided in the SSP SSPSOL550_033 into a temporary directory in the Solaris
DP CC System, referred to as “Extraction Directory” henceforth, by executing following from the
command prompt: # sh SSPSOL550_033.shar
A directory SSPSOL550_033 will be created under the <Extraction Directory> in the Solaris DP
CC System and the following files will be placed in the directory <Extraction
Directory>/SSPSOL550_033/ after execution of the preceding command:
o libadmin.so
o libbackup.so
o libclients.so
o libcopy.so
o libcore.so
o libdatabase.so
o libinstrest.so
o libmonitor.so
o libreport.so
o librestore.so
o libusers.so
o xomni_manager
o xomni_mom
o bsm
o rsm
o csm
o Install_SSPSOL550_033.sh
o SSPSOL550_033.txt

5. Make copies of the original existing binaries listed later in the Solaris DP CC System. Copy the
following binaries from the directory <Extraction Directory>/SSPSOL550_033/ to the directory
<OMNIHOME>/gui/bin/ in the Solaris DP CC System:
o libadmin.so
o ibbackup.so
o libclients.so
o libcopy.so
o libcore.so
o libdatabase.so

11
o libinstrest.so
o libmonitor.so
o libreport.so
o librestore.so
o libusers.so
o xomni_manager
o xomni_mom

6. Re-start the Storage Data Protector GUI in the Solaris DP CC System by executing xomni& from
the command prompt.

2.3. Instructions for installing SSPUX550_122 for HP-UX DP CC System


The patch SSPUX550_122.exe contains:
o libadmin.sl
o libbackup.sl
o libclients.sl
o libcopy.sl
o libcore.sl
o libdatabase.sl
o libinstrest.sl
o libmonitor.sl
o libreport.sl
o librestore.sl
o libusers.sl
o xomni_manager
o xomni_mom
o bsm
o rsm
o csm
o Install_SSPUX550_122.sh
o SSPUX550_122.txt

1. Log on to the HP-UX DP CC System where you want to apply this patch.
2. Be sure that you have applied the latest Core and CC general release patches to the HP-UX DP CC
System, which are PHSS_34497 (Core) and PHSS_34330 (CC) (or one of their successors) if you
use an HP-UX PA Installation Server in your Storage Data Protector cell. If you use an HP-UX IA
Itanium® system as Installation Server in your Storage Data Protector cell, then the patches are
PHSS_34498 (Core) and PHSS_34331 (CC) or one of their successors.
3. Close Storage Data Protector UI sessions in the HP-UX DP CC System.
4. Unshar the binaries provided in SSP SSPUX550_122 into a temporary directory in the HP-UX DP
CC System, referred to as “Extraction Directory” henceforth, by executing following from the
command prompt: # sh SSPUX550_122.shar

12
A directory SSPUX550_122 will be created under the <Extraction Directory> in the HP-UX DP CC
System and the following files will be placed in the directory <Extraction
Directory>/SSPUX550_122/ after execution of the preceding command:

o libadmin.sl
o libbackup.sl
o libclients.sl
o libcopy.sl
o libcore.sl
o libdatabase.sl
o libinstrest.sl
o libmonitor.sl
o libreport.sl
o librestore.sl
o libusers.sl
o xomni_manager
o xomni_mom
o bsm
o rsm
o csm
o Install_SSPUX550_122.sh
o SSPUX550_122.txt

5. Make copies of the original existing binaries listed later in the HP-UX DP CC System. Copy the
following binaries from the directory <Extraction Directory>/SSPUX550_122/ to the directory
<OMNIHOME>/gui/bin/:
o libadmin.sl
o libbackup.sl
o libclients.sl
o libcopy.sl
o libcore.sl
o libdatabase.sl
o libinstrest.sl
o libmonitor.sl
o libreport.sl
o librestore.sl
o libusers.sl
o xomni_manager
o xomni_mom

6. Re-start the Storage Data Protector UI in the HP-UX DP CC System by executing xomni& from the
command prompt.

13
3. Installing the core and agent patches for Microsoft
Windows 2003 x86-64 support
For all the agents to function properly, the core components are bundled together and released as an
Agent Core SSP, which is SSPNT550_111. So, on the Microsoft Windows x86_64 client system, use
the following instructions to apply the Core SSP.

3.1. Instructions for installing Agent Core SSP (SSPNT550_111)


The patch SSPNT550_111.exe contains:
• OmniEnu.dll
• OmniInet.exe
• srdx.dll
• sysnfowxp.dll
• BrandChgUni.dll
• omnirc.tmpl
• scsitab
• REGSSPNT550_111.reg

1. Log on to the <Target System> where you want to apply the patch
2. Uninstall any existing Storage Data Protector installations using the Start, Settings, Control Panel,
Add/Remove Programs and by selecting HP OpenView Storage Data Protector A.05.50 from the
list of installed programs.
3. (This step is needed to ensure that the previous step executed properly and Storage Data Protector
was uninstalled properly in the <Target System> as sometimes the uninstall fails to clean up all the
Registry Entries properly.) Check whether the DP OmniBack Registry Entries in the WOW64 node
under HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\Hewlett-Packard\ OpenView and
KEY_LOCAL_MACHINE\SOFTWARE\Hewlett-Packard\OpenView are cleaned up. Otherwise,
delete these entries manually.
4. Stop the OmniInet service if it is still running. This step is required because sometimes the uninstall
fails to stop or delete the OmniInet service.
5. If any OmniBack folders still exist in <Program files x86 Home> or <Program files Home>, then
delete it by executing from command prompt: rmdir /S /Q OmniBack. This step is required
because sometimes the uninstall fails to remove the OmniBack directories.
6. Create the following directories under <Program files Home> by executing these commands:
o mkdir OmniBack
o mkdir OmniBack\bin
o mkdir OmniBack\Config
o mkdir OmniBack\Config\client
o mkdir OmniBack\log
o mkdir OmniBack\tmp

7. Extract the binaries from (self-extracting) SSPNT550_111.exe under any folder in <Target
System>, referred to as <Extraction Folder> henceforth.
8. Copy omnirc.tmpl from the <Extraction Folder> to <OMNIHOME>.
9. Copy OmniEnu.dll, OmniInet.exe, sysnfowxp.dll, and srdx.dll from the <Extraction Folder> into
<OMNIHOME>\bin.
10. Copy BrandChgUni.dll from the <Extraction Folder> to C:\Windows\system32.

14
11. The file REGSSPNT550_111.reg in the <Extraction Folder> is a registry file. It contains Storage
Data Protector settings to be merged into the System Registry. To perform the merge, double-click
the file or press the right mouse button, then choose Merge.
The merge will set default paths for the DataProtector to C:\Program Files\OmniBack. If some
other directory is used as the <OMNIHOME>, then modify this registry file accordingly for the
”Exclude” and ”HomeDir” entries and then merge it by right-clicking the registry file and selecting
Merge from the options.

12. Register OmniInet as a service (if it is not registered) by using sc.exe utility from the following
command prompt:
sc create omniinet binPath="<OMNIHOME>\bin\OmniInet.exe"
DisplayName= "Data Protector Inet" start= auto
sc description omniinet "[HP OpenView Storage Data Protector]—Backup
client service"
13. Start OmniInet service from the command prompt: sc start omniinet

Installation of the agents


After SSPNT550_111 is installed, the Target System is ready for the installation of any of the 64-bit
enabled Storage Data Protector agents. The order of installation of Agents is not of concern unless
specified in installation instructions.

3.2. Installation instructions for Disk Agent (SSPNT550_118)


The patch SSPNT550_118.exe contains:
• fsbrda.exe
• libdc.dll
• libde.dll
• rbda.exe
• rrda.exe
• vbda.exe
• vrda.exe
• omni_info

1. Extract the SSPNT550_118.exe binaries under any folder in <Target System>, referred as
<Extraction Folder> henceforth.
2. Copy the following binaries from the <Extraction Folder> into <OMNIHOME>\bin:
o fsbrda.exe
o libdc.dll
o libde.dll
o rbda.exe
o rrda.exe
o vbda.exe
o vrda.exe

15
3. If omni_info file is not present in <OMNIHOME>\Config\client, then copy the file omni_info from
the <Extraction Folder> to <OMNIHOME>\Config\client. Otherwise, append the contents of the
omni_info file located in the <Extraction Folder> to the existing omni_info file under
<OMNIHOME>\Config\client directory.
4. Import the client in your Storage Data Protector Cell Manager by connecting to the Cell Manager
from the GUI, if the <Target System> is not already shown in the list of clients in the Storage Data
Protector Cell Manager. (For more information on importing a client, refer to HP Storage Data
Protector documentation.) For further details, refer to “Preparing the Storage Data Protector Cell
Console (CC) System before importing the Microsoft Windows 2003 x86-64 client” section.
If the <Target System> is already listed in the list of clients in the Storage Data Protector Cell
Manager, then delete the <Target System> from the list of clients in that Storage Data Protector
Cell Manager without uninstalling Storage Data Protector software by right-clicking the <Target
System> in the list of clients for the Cell Manager, then selecting Delete from the list of options
shown and selecting No when prompted to uninstall Storage Data Protector software from the
<Target System> client. Then, re-import the <Target System> client in your Storage Data Protector
Cell Manager. (For more information on importing a client, refer to HP Storage Data Protector
documentation.)
The <Target System> is now ready for running the Disk Agent.

3.3. Installation instructions for Media Agent (SSPNT550_130)


The patch SSPNT550_130.exe contains:
• uma.exe
• bma.exe
• cma.exe
• devbra.exe
• mma.exe
• rma.exe
• omni_info
• scsitab

1. Extract the SSPNT550_130.exe binaries under some folder in <Target System>, referred as
<Extraction Folder> henceforth.
2. Copy the following binaries from the <Extraction Folder> into <OMNIHOME>\bin:
o uma.exe
o bma.exe
o cma.exe
o devbra.exe
o mma.exe
o rma.exe

3. Copy the scsitab from the <Extraction Folder> to <OMNIHOME>.


4. If omni_info file is not present in <OMNIHOME>\Config\client, then copy the file omni_info from
the <Extraction Folder> to <OMNIHOME>\Config\client. Otherwise, append the contents of the
omni_info file located in the <Extraction Folder> to the existing omni_info file.

16
5. Import the client in your Storage Data Protector Cell Manager by connecting to the Cell Manager
from the GUI, if the <Target System> is not already shown in the list of clients in the Storage Data
Protector Cell Manager. (For more information on importing a client, refer to HP Storage Data
Protector documentation.) For further details, refer to ”Preparing the Storage Data Protector Cell
Console (CC) System before importing the Microsoft Windows 2003 x86-64 client” section.
If the <Target System> is already listed in the list of clients in the Storage Data Protector Cell
Manager, then delete the <Target System> from the list of clients in that Storage Data Protector
Cell Manager without uninstalling Storage Data Protector software by right-clicking the <Target
System> in the list of clients for the Cell Manager, then selecting Delete from the list of options
shown and selecting No when prompted to uninstall Storage Data Protector software from the
<Target System> client. Then, re-import the <Target System> client in your Storage Data Protector
Cell Manager. (For more information on importing a client, refer to HP Storage Data Protector
documentation.)
The <Target System> is now ready for running the Media Agent.

3.4. Installation instructions for SMISA Agent (SSPNT550_100)


The patch SSPNT550_100.exe contains:
• smisa.exe
• pegcommon.dll
• pegclient.dll
• libexpatw.dll
• libexpat.dll
• omni_info

1. Install the DA patch SSPNT550_118 (if it is not installed already) by following the installation
instructions given for that patch.
2. Extract the SSPNT550_100.exe binaries under some folder in <Target System>, referred as
<Extraction Folder> henceforth.
3. Copy the following binaries from the “Extraction Folder” into <OMNIHOME>\bin:
o smisa.exe
o pegcommon.dll
o pegclient.dll
o libexpatw.dll
o libexpat.dll

4. If omni_info file is not present in <OMNIHOME>\Config\client, then copy the file omni_info from
the <Extraction Folder> to <OMNIHOME>\Config\client. Otherwise, append the contents of the
omni_info file located in the <Extraction Folder> to the existing omni_info file.
5. Import the client in your Storage Data Protector Cell Manager by connecting to the Cell Manager
from the GUI, if the <Target System> is not already shown in the list of clients in the Storage Data
Protector Cell Manager. (For more information on importing a client, refer to HP Storage Data
Protector documentation). For further details, refer to “Preparing the Storage Data Protector Cell
Console (CC) System before importing the Microsoft Windows 2003 x86-64 client” section.

17
If the <Target System> is already listed in the list of clients in the Storage Data Protector Cell
Manager, then delete the <Target System> from the list of clients in that Storage Data Protector
Cell Manager without uninstalling Storage Data Protector software by right-clicking the <Target
System> in the list of clients for the Cell Manager, then selecting Delete from the list of options
shown and selecting No when prompted to uninstall Storage Data Protector software from the
<Target System> client. Then, re-import the <Target System> client in your Storage Data Protector
Cell Manager. (For more information on importing a client, refer to HP Storage Data Protector
documentation.)
The <Target System> is now ready for running the SMISA Agent.

3.5. Installation instructions for SQL Agent (SSPNT550_131)


The patch SSPNT550_131.exe contains:
• sql_smb.exe
• sql2000_ma.dll
• sql_bar.exe
• sql_ma.dll
• omni_info

1. Install Microsoft SQL Server 2005 for x86-64 on the <Target System>.
2. Install the DA patch SSPNT550_118 (if it is not installed already) by following the installation
instructions given for that patch.
3. Extract the SSPNT550_131.exe binaries under some folder in <Target System>, referred as
<Extraction Folder> henceforth.
4. Copy the following binaries from the <Extraction Folder> into <OMNIHOME>\bin:
o sql_smb.exe
o sql2000_ma.dll
o sql_bar.exe
o sql_ma.dll

5. If omni_info file is not present in <OMNIHOME>\Config\client, then copy the file omni_info from
the <Extraction Folder> to <OMNIHOME>\Config\client. Otherwise, append the contents of the
omni_info file located in the <Extraction Folder> to the existing omni_info file.
6. Import the client in your Storage Data Protector Cell Manager by connecting to the Cell Manager
from the GUI, if the <Target System> is not already shown in the list of clients in the Storage Data
Protector Cell Manager. (For more information on importing a client, refer to HP Storage Data
Protector documentation.) For further details, refer to “Preparing the Storage Data Protector Cell
Console (CC) System before importing the Microsoft Windows 2003 x86-64 client” section.
If the <Target System> is already listed in the list of clients in the Storage Data Protector Cell
Manager, then delete the <Target System> from the list of clients in that Storage Data Protector
Cell Manager without uninstalling Storage Data Protector software by right-clicking the <Target
System> in the list of clients for the Cell Manager, then selecting Delete from the list of options
shown and selecting No when prompted to uninstall Storage Data Protector software from the
<Target System> client. Then, re-import the <Target System> client in your Storage Data Protector
Cell Manager. (For more information on importing a client, refer to HP Storage Data Protector
documentation.)

18
The <Target System> is now ready for running the SQL Agent.

Limitation
This SSP does not implement the new Microsoft SQL 2005 “tail-logs”
feature. The “force restore over existing database” option must be
used at restore time. Restore of a Microsoft SQL 2005 database will
not work without it.

3.6. Installation instructions for SAP Agent (SSPNT550_126)


The patch SSPNT550_126.exe contains:
• backint.exe
• omnisap.exe
• sapback.exe
• saprest.exe
• util_sap.exe
• testbar.exe
• testbar2.exe
• ob2smbsplit.exe
• saproll.exe
• omni_info

1. Install the DA patch SSPNT550_118 (if it is not installed already) by following the installation
instructions given for that patch.
2. Extract the SSPNT550_126.exe binaries under some folder in <Target System>, referred as
<Extraction Folder> henceforth.
3. Copy the following binaries from the ”Extraction Folder” into <OMNIHOME>\bin in the Target
System:
o backint.exe
o omnisap.exe
o sapback.exe
o saprest.exe
o util_sap.exe
o testbar.exe
o testbar2.exe
o ob2smbsplit.exe
o saproll.exe

4. If omni_info file is not present in <OMNIHOME>\Config\client, then copy the file omni_info from
the <Extraction Folder> to <OMNIHOME>\Config\client. Otherwise, append the contents of the
omni_info file located in the <Extraction Folder> to the existing omni_info file.
5. Import the client in your Storage Data Protector Cell Manager by connecting to the Cell Manager
from the GUI, if the <Target System> is not already shown in the list of clients in the Storage Data
Protector Cell Manager. (For more information on importing a client, refer to HP Storage Data
Protector documentation.) For further details, refer to “Preparing the Storage Data Protector Cell
Console (CC) System before importing the Microsoft Windows 2003 x86-64 client” section.

19
If the <Target System> is already listed in the list of clients in the Storage Data Protector Cell
Manager, then delete the <Target System> from the list of clients in that Storage Data Protector
Cell Manager without uninstalling Storage Data Protector software by right-clicking the <Target
System> in the list of clients for the Cell Manager, then selecting Delete from the list of options
shown and selecting No when prompted to uninstall Storage DP software from the <Target
System> client. Then, re-import the <Target System> client in your Storage Data Protector Cell
Manager. (For more information on importing a client, refer to HP Storage Data Protector
documentation.)
The <Target System> is now ready for running the SAP Agent.

3.7. Installation instructions for XP/SSEA Agent (SSPNT550_102)


The patch EXE SSPNT550_102.exe contains:
• ssea.exe
• smbw2k.dll
• omni_info

1. Install the DA patch SSPNT550_118 for Microsoft Windows 2003 x86-64 (if it is not installed
already) by following the installation instructions given in that SSP in the x86-64 Target System.
2. Extract the binaries provided in this package SSPNT550_102 to some folder in your x86-64
Target System, referred to as the “Extraction Folder” henceforth.
3. Copy the following binaries from the “Extraction Folder” into <OMNIHOME>\bin in the x86-64
Target System:
o ssea.exe
o smbw2k.dll

4. Copy the file omni_info from the “Extraction Folder” to <OMNIHOME>\Config\client in the x86-
64 Target System, if omni_info file does not exist in <OMNIHOME>\Config\client directory. If
omni_info file is already present under <OMNIHOME>\Config\client, then append the content of
the omni_info file provided in this package SSPNT550_102 to the existing omni_info file.
5. Import the client in your Storage Data Protector Cell Manager by connecting to the Cell Manager
from the GUI, if the <Target System> is not already shown in the list of clients in the Storage Data
Protector Cell Manager. (For more information on importing a client, refer to HP Storage Data
Protector documentation.) For further details, refer to “Preparing the Storage Data Protector Cell
Console (CC) System before importing the Microsoft Windows 2003 x86-64 client” section.
If the <Target System> is already listed in the list of clients in the Storage Data Protector Cell
Manager, then delete the <Target System> from the list of clients in that Storage Data Protector
Cell Manager without uninstalling Storage Data Protector software by right-clicking the <Target
System> in the list of clients for the Cell Manager, then selecting Delete from the list of options
shown and selecting No when prompted to uninstall Storage Data Protector software from the
<Target System> client. Then, re-import the <Target System> client in your Storage Data Protector
Cell Manager. (For more information on importing a client, refer to HP Storage Data Protector
documentation.)
The <Target System> is now ready for running the SSEA Agent.

20
3.8. Installation instructions for MAXDB Integration Agent
(SSPNT550_135)
The patch SSPNT550_135.exe contains:
• sapdb_backint.exe
• sapdbbar.exe
• util_sapdb.exe
• dma.exe

1. Install the DA patch SSPNT550_118 (if it is not installed already) by following the installation
instructions given for that patch.
2. Extract the SSPNT550_135.exe binaries under some folder in <Target System>, referred as
<Extraction Folder> henceforth.
3. Copy the following binaries from the “Extraction Folder” into <OMNIHOME>\bin in the Target
System:
o sapdb_backint.exe
o sapdbbar.exe
o util_sapdb.exe
o dma.exe

4. Append the following line at the end of existing <OMNIHOME>\Config\client\omni_info file:


-key sapdb -desc "SAP DB Integration" -nlsset 159 -nlsId 12195 -flags 0x7 -ntpath "" -uxpath "" -
version A.05.50
5. Import the client in your Storage Data Protector Cell Manager by connecting to the Cell Manager
from the GUI, if the <Target System> is not already shown in the list of clients in the Storage Data
Protector Cell Manager. (For more information on importing a client, refer to HP Storage Data
Protector documentation.) For further details, refer to “Preparing the Storage Data Protector Cell
Console (CC) System before importing the Microsoft Windows 2003 x86-64 client section.
If the <Target System> is already listed in the list of clients in the Storage Data Protector Cell
Manager, then delete the <Target System> from the list of clients in that Storage Data Protector
Cell Manager without uninstalling Storage Data Protector software by right-clicking the <Target
System> in the list of clients for the Cell Manager, then selecting Delete from the list of options
shown and selecting No when prompted to uninstall Storage Data Protector software from the
<Target System> client. Then, re-import the <Target System> client in your Storage Data Protector
Cell Manager. (For more information on importing a client, refer to HP Storage Data Protector
documentation.)
The <Target System> is now ready for running the MAXDB Agent.

3.9. Installation instructions for future Storage Data Protector integration


agent patches
For specific details, refer to the Readme texts of the respective SSP patches.

21
For more information
For more information on HP OpenView Storage Data Protector, visit:
http://www.hp.com/go/dataprotector

© 2006 Hewlett-Packard Development Company, L.P. The information contained


herein is subject to change without notice. The only warranties for HP products and
services are set forth in the express warranty statements accompanying such
products and services. Nothing herein should be construed as constituting an
additional warranty. HP shall not be liable for technical or editorial errors or
omissions contained herein.

Itanium is a registered trademark of Intel Corporation or its subsidiaries in the


United States and other countries. Microsoft and Windows are U.S. registered
trademarks of Microsoft Corporation.
4AA0-7171ENW, August 2006

You might also like