Professional Documents
Culture Documents
Accendo DHID lighting solutions outperform with the perfect balance of low initial buying cost,
energy efficiency, light quality/penetration performance over the long term, and really low
maintenance/ consumable costs for Industry’s best return on lighting investment.
Please explore our Digital HID (DHID) products and their applications on the following pages.
Appendix
For typical existing Low-bay/High-bay and Street/Parking Lot HID light fixture applications, a core and coil
(magnetic) ballast of 70W to 1,000W power will be upgraded. For a magnetic 250W fixture upgrade, for example,
a GloGreen DHID 100W or 150W retrofit ballast is installed; for an existing magnetic 400W fixture, the GloGreen
DHID 250W retrofit ballast is installed.
Internal Retrofit
External Retrofit
Install GloGreen 400W, 575W, 600W, 750W and 1000W DHID retrofit
ballasts to upgrade existing magnetic 575W – 2000W fixture ballasts.
Please follow these installation rules when deciding on a proper installation/mounting location:
1. Sub-zero temperature environment is not critical for the operation of the Digital HID ballasts. If the
recommended HID lamp can work in a given sub-zero environment, the DHID ballast will ignite it.
2. The upper limit of 72°C/161.6°F case temperature (Tc) is critical. If Tc exceeds 72°C/161.6°F
the life expectancy of the DHID ballast will be compromised.
3. External installation of the DHID ballast is preferred (especially for GloGreen 200/250W,
250W, 400W, 600W, 750W and 1000W ballasts.
4. If the DHID ballast is to be installed in an enclosure, specific steps must be taken to
ensure that Tc will not exceed 72°C/161.6°F over a prolonged time span.
5. If there is any doubt about the level of Tc, a test installation is required and should be performed
where the Tc case temperature is being monitored under a "worst case scenario".
6. Do not install the DHID ballast inside of Wallpack and similar small fixtures where the proximity
of the High-Intensity Discharge lamp is very close to the DHID ballast; if this is the only
consideration, a temperature test should be performed on the ballast to ensure it is not
operating above the maximum 72°C/161.6°F case temperature rating.
7. As to not exceed the rated 72°C/161.6°F ballast case temperature, a proper mounting bracket
or heat sink should be installed (please refer to pages 2 and 3 of this package for additional
details). Proper heat sinking of the DHID ballast can lower the Tc by as much as 10°C/50°F
to 14°C/57.2°F.
Digital HID ballast products from Accendo Electronics are warrantied for defects from manufacturing and workmanship for a period
of 3 years. During this warranty period, Accendo Electronics reserves the right to repair or replace ballast products which prove to be
defective or out of specification at their discretion. The Accendo warranty is valid only for the original purchaser or the first end user
of the ballast products.
This warranty is conditional upon installation, maintenance and operation adhering to instructions and specifications defined by
Accendo Electronics in the purchase order or contract at the time of the order and in accordance with the standards of Canadian
Standards Association (CSA), the American National Standards Institute (ANSI), Underwriters Laboratory Inc (UL) and The
National Electric Code (NEC).
Damage by misuse or abnormal conditions of storage, installation, maintenance or operation, including, but not limited to, excessive
temperatures or evidence of partial or complete disassembly beyond normal maintenance or expansion procedure void this warranty in
its entirety. The conditions of any tests performed concerning any ballast product claimed to be defective in accordance with the terms
of this warranty shall be mutually agreed upon in writing between the original purchaser or first end-user and Accendo Electronics.
Accendo Electronics reserves the right to be represented at any such test.
Dimming
Accendo Electronics Ltd. agrees to extend a limited three-year warranty on dimmable DHID ballasts and fixtures operated on
dimmable control gear, such as motion sensors, provided the following conditions are met:
1) A lamp must never be started by a ballast operating in the dimmed operating mode.
2) During any lamp start (cold or hot restart), the ballast must meet all of the requirements for starting and sustaining a lamp described
in the applicable ANSI document C78.13xx for that lamp.
3) The lamp must be allowed to warm up for at least 10 minutes after the lamp has started (20 minutes for lamp wattages greater than
450). Only then can dimming begin.
4) The ballast input voltage must be kept within the accepted line voltage range for the ballast type (±10% for DHID ballasts)
5) The dimming device should not allow the ballast current crest factor to exceed 1.8.
HID Lamps
Accendo’s warranty statement does not include lamps. For any warranty on lamps the applicable warranty statement of the lamp
manufacturer shall apply. Only lamps recommended and approved by Accendo shall be used with Accendo’s DHID ballasts.