You are on page 1of 4

CENTER FOR TRANSPORTATION RESEARCH

THE UNIVERSITY OF TEXAS AT AUSTIN

Project Summary Report 1874-S


Center for Assessment of Cohesionless Materials to Be Used as Compacted Fill
Transportation Research
The University of Texas at Austin Authors: Stephen G. Wright, Brad J. Arcement, and Eric R. Marx

Recommended Compaction Requirements for Placement


of Uniform Fine Sand Backfill Materials

Objective and Scope Particular attention was paid pacted using each of the
to the laboratory compaction following compaction proce-
of Project
REPORT

procedures used and the dures:


The objective of this specifications for field • TxDOT Tx 113-E-
project was to develop compaction. Laboratory Compaction
recommendations for com- Selection of Soil for Testing Characteristics and
paction of cohesionless soils TxDOT selected several Moisture-Density Rela-
used as backfill materials. sources of cohesionless fill tionship of Base Materials
The Texas Department of materials for testing and • ASTM D 1557-Labora-
Transportation (TxDOT) evaluation. Initially, attention tory Compaction Charac-
utilizes a number of sources was focused on the El Paso teristics of Soil Using
of cohesionless soils as fill area where abundant sources Modified Effort
materials for embankment of cohesionless fill materials • British Standard BS-1377
SUMMARY

construction and as backfill are available and used. Nine -Vibrating Hammer
for mechanically stabilized sources of fill material were Method
earth (MSE) walls. Some identified in the El Paso area • ASTM D 4253-Maximum
problems have been experi- and samples were obtained Index Density and Unit
enced with these materials in for further laboratory testing. Weight of Soils Using a
the past, especially with After the initial selection of Vibratory Table
settlements of backfills soils from the El Paso area, All tests using the Tx
behind retaining walls. the study scope was widened 113-E procedure were per-
TxDOT sought a suitable to include soils from the formed using a special
procedure for placement of Houston, Fort Worth, Beau- hammer and neoprene pad
these materials that would mont, Corpus Christi, and recommended in the Tx 113-
ensure satisfactory perfor- Austin regions. Fourteen E test procedure for “materi-
mance. different cohesionless fill als difficult to compact.” For
PROJECT

materials were selected for all soils compacted using the


What We Did... study. Samples of each of ASTM D 4253 procedure, the
Survey of State Department of these soils were obtained for minimum density was also
Transportation Compaction further laboratory testing. determined using the ASTM
Requirements D 4254 test procedure (mini-
Laboratory Testing Program
Most of the state depart- mum index density and unit
Laboratory testing in-
ments of transportation weight of soils, and calcula-
cluded basic index properties
(DOTs) in the United States tion of relative density). The
and grain size distribution for
were surveyed regarding their maximum and minimum
classification of each soil.
requirements for compaction densities determined by
Most of the soils were com-
of cohesionless fill materials.

Project Summary Report 1874-S –1–


ASTM D 4253 and 4254 proce- 2. Most DOTs use either the 6. The modified proctor (ASTM
dures were used to calculate standard proctor (ASTM D D 1557) compactive effort
relative densities for the soils 698) or modified proctor produced maximum dry unit
tested. In most cases, complete (ASTM D 1557) compaction weights that met or exceeded
moisture-density curves were procedures for specifying the maximum density ob-
obtained for each soil using the field density requirements for tained by the ASTM D 4253
compaction procedures listed cohesionless soils. Standard procedure for ten of the
above. proctor compactive effort is fourteen soils tested. For the
Grain size distributions were used more commonly than four soils that showed lower
determined for samples of many modified proctor compactive densities by the modified
of the soils before and after effort. proctor procedure, the densi-
compaction to determine if any 3. Most of the soils selected by ties were no less than 3
significant particle breakage TxDOT and tested in this percent below the maximum
occurred during the compaction study were uniform fine density obtained by the
process. sands. Six of the soils were ASTM D 4253 procedure.
Several soils were selected classified as SP (poorly These results all indicate that
for additional testing to determine graded sand) by the unified the modified proctor maxi-
the amount of compression soil classification system. mum dry density represents a
produced when the soils were Two of the soils were classi- relatively high degree of
subjected to load and, subse- fied as SM (silty sand) soils. compaction for cohesionless
quently, inundated with water. Finally, six more of the soils soils like the ones tested.
The objective of these tests was to were classified by the dual 7. The Tx 113-E compaction
determine what compaction levels classification symbols as SP- procedure produced maxi-
were required to reduce post- SM soils. mum dry unit weights that in
construction settlements of the fill 4. Many of the soils showed no all cases exceeded the maxi-
materials to acceptable limits. distinct optimum water mum dry density determined
content; the moisture density by the ASTM D 4253 test
What We Found... curves were flat with no procedure. The densities
1. A review of other states’ DOT pronounced peak. This was determined by the Tx 113-E
compaction requirements especially true for the soils procedure ranged from
revealed that none of them classified as SP and SP-SM approximately 1 to 16 percent
used relative density (Ameri- soils. higher than the densities
can Society for Testing and 5. For most of the soils tested, tested by the ASTM D 4253
Materials (ASTM)) as a basis no significant change in grain procedure. These results
for specifying compaction of size distribution was observed indicate that the Tx 113-E
cohesionless fill materials. after compaction, indicating compaction procedure pro-
Although relative density is that particle breakage was duces a very high degree of
generally thought to be the minimal. Except for one soil, compaction for cohesionless
best indicator of degree of the percent increase in par- soils like the ones tested in
compactness for cohesionless ticles by weight passing the this study.
fill materials, relative density No. 200 sieve was less than 4 8. Tests on six of the soils using
does not seem to be used percent. Only one soil the British vibratory hammer
much for compaction control. described as “caliche” showed dry unit weights that
Relative density is difficult to showed a larger change in ranged from about 3 to 10
determine and great care is grain size distribution because percent greater than the
required to obtain reproduc- of compaction; for this soil, ASTM D 4253 maximum
ible results. Because of the the percent by weight passing density. These results con-
complexity and difficulties the No. 200 sieve increased firm that the British vibratory
involved, relative density is by approximately 9 percent. hammer also produces a
apparently not used. relatively high degree of

Project Summary Report 1874-S –2–


compaction in cohesionless to adversely affect the use of to specify and control com-
soils. the modified proctor (ASTM paction, it is recommended
9. It is difficult to maintain a D 1557) compaction test for that the soil be compacted to
constant, consistent control of densities in com- 92 percent of the maximum
compactive effort with the pacted fills. dry unit weight determined by
British vibratory hammer, and 12. In one instance where cohe- the Tx 113-E procedure.
the test was judged to be the sionless fills were observed 5. For cohesionless soils like the
most difficult of the compac- being compacted in the field ones tested, if the compaction
tion procedures investigated. and difficulties were encoun- moisture density curve
Because of the difficulty and tered, it was observed that exhibits a well-defined peak
lack of widespread use in two different nuclear density and optimum water content,
Texas, the procedure was not .
gauges were giving grossly the soil should be compacted
used for all soils and was inaccurate results. Both using a water content ap-
considered less suitable than gauges indicated dry unit proximately equal to the
the other procedures used on weights that were substan- optimum water content. If no
practical grounds. tially less than the actual dry well-defined peak in the
10. The version of the Tx 113-E unit weight as determined moisture density curve is
compaction procedure that when using other measure- observed, the soil should be
uses a special ram and neo- ments of density. compacted with significant
prene pad over the surface of water, e. g., corresponding to
the soil does not seem to be The Researchers 50 to 75 percent saturation or
widely understood and used Recommend... the maximum amount of
by TxDOT. The procedure 1. Suitable specification and moisture that can be retained.
was judged to be more control of compaction cohe- Adequate moisture is neces-
complex and difficult to use sionless fill materials can be sary to prevent significant
than the modified proctor achieved using either the postconstruction settlements,
(ASTM D 1557) procedure. modified proctor (ASTM D even with compaction to the
Obtaining good, consistent 1557) or Tx 113-E (with levels recommended above.
results among laboratories neoprene pad and special 6. These recommendations are
with the Tx 113-E procedure compaction hammer) proce- based principally on tests
may be much more difficult dures. performed on uniform fine
than with the modified 2. The modified proctor ( ASTM sands classified as SP or SP-
proctor (ASTM D 1557) D 1557) compaction proce- SM soils by the unified soil
procedure. dure is preferred to the Tx classification sytem. Some
11. There is a noticeable variation 113-E procedure, because the modifications may be appro-
in vertical dry unit weight in ASTM procedure is simpler priate for other soils, e. g.,
the compaction mold for the and more likely to be carried some SM soils and well-
modified proctor compaction out properly by laboratories, grained sands and gravels
test and this may explain why both inside and outside (SW, GW).
the dry unit weight for several TxDOT. 7. Procedures for calibration of
of the soils tested was slightly 3. When the modified proctor nuclear gauges used for field
less than the maximum compaction procedure is used density measurement and
density obtained by the for compaction specification control should be reevaluated
ASTM D 4253 procedure. and control, compaction to 95 and carefully checked. In at
This was particularly notice- percent of the maximum dry least some instances, the
able for the sands containing unit weight is recommended. nuclear gauges being used are
very few fines, i.e., the soils 4. If the Tx 113-E compaction not properly calibrated and
classified as SP soils. How- procedure (with neoprene pad are yielding erroneous results.
ever, the variation in density and special hammer) is used
does not seem to be sufficient

Project Summary Report 1874-S –3–


For More Details...
Research Supervisor: Stephen G. Wright, Ph.D., P.E., The University of Texas at Austin, Civil
Engineering Department, (512) 471-4929, swright@mail.utexas.edu.
Researchers: Brad J. Arcement, Eric R. Marx, and Brian L. Christensen

TxDOT Project Director: Marcus Galvan, Bridge Division, (512) 416-2224.

The research is documented in the following reports:

Report 1874-1: Evaluation of Laboratory Compaction Procedures for Specification of Densities for
Compacting Fine Sands, January 2001.

To obtain copies of a report: CTR Library, Center for Transportation Research,


(512) 232-3138, email: ctrlib@uts.cc.utexas.edu

TxDOT Implementation Status


January 2002
The research results recommend uniform fine sands be compacted to 95% modified proctor (ASTM
D 1557) maximum dry unit weight for settlement-critical applications. It is expected this recommenda-
tion will be adopted and incorporated into the rewrite of the Texas Department
of Transportation’s Standard Specifications for Construction of Highways, Streets and Bridges.
For more information please contact Tom Yarbrough, P.E., RTI Research Engineer, at
(512) 465-7685 or email at tyarbro@dot.state.tx.us.

Your Involvement Is Welcome!

Disclaimer
This research was performed in cooperation with the TxDOT and the U.S. Department of Transportation, Federal
Highway Administration (FHWA). The contents of this report reflect the views of the authors, who are responsible for the
facts and accuracy of the data presented herein. The contents do not necessarily reflect the official view or policies of the
FHWA or TxDOT. This report does not constitute a standard, specification, or regulation, nor is it intended for construction,
bidding, or permit purposes. Trade names were used solely for information and not for product endorsement. The engineer
in charge was Stephen G. Wright, P.E.

Center for
Transportation Research
The University of Texas at Austin

The University of Texas at Austin


Center for Transportion Research
3208 Red River, Suite #200
Austin, TX 78705-2650

Project Summary Report 1874-S –4–

You might also like