Description

The SensaTank II console is a simple low-voltage panel that displays the liquid level within non-metallic tanks. Non-
metallic tank wall thickness can be up to 10mm (0.39") SensaTank II kits are available for 2, 3, or 4 tanks.

How It Works How to Operate the Console

• SensaTank II uses ultra-reliable Mirus™ Detector • Press a round console button to check a tank’s
Cells to measure each tank’s liquid level. level.
• The Detector Cells create a sensory field through • The lighted console shines progressively to show
the tank wall. They sense the fluid level but never the level of the selected tank.
contact the liquid. • Release button to turn off console or to check
another tank.

TouchSensor Technologies, LLC


203 North Gables Blvd.
Wheaton, IL 60187
ISO 9001:2000
SENSATANK II™ INSTALLATION INSTRUCTIONS
Mounting Locations and Requirements 5. Repeat procedure to attach Detector Cells to volume
1. Display Console — points on remaining tank(s).
• Clearance required: 0.5" D, 2.75” W, 2.25" H 6. Label each cable for the tank to which it is connected
(13mm D, 70mm W, 57mm H). (Fresh Water, Holding Tank, etc.).
• 1-amp fused power source, ± 10.5 to 14.4 VDC. Wiring and Assembly
• Solid connection to frame ground or battery negative IMPORTANT:
terminal. To ensure product performance, all wiring connections must
• Display Console can be damaged by moisture — mount meet specifications below. Failure to follow instructions can
ONLY in a dry location. void product warranty.
2. SensaTank Detector Cells — • Added wire must be 16-gauge minimum.
• Not affected by moisture. • Make connections high and dry with waterproof crimp
• Mount to exterior of non-metallic, plastic tanks. connectors.
Maximum tank wall thickness is up to 10mm (0.39"). • Provide strain relief for all splices and plug connections.
• Tank distance from Display Console: 1. If necessary, splice in extra color-coded wire (black & black/
100 ft.(30.5 meters) max.
white stripe) so Detector Cell cables reach Display
Cut Opening for Display Console Console. Be sure each cable is labeled.
1. At chosen mounting location, cut a hole 2.75" W by 2.25" H 2. Pull cables through the Display Console cutout.
(70 by 57mm) for the Display Console. 3. Splice all black/white striped wires to the Display Console
2. Do not mount the Display Console until Detector Cell wiring grey wire. Splice black wires to match color-coding shown
is complete. in drawing. SensaTank II kit may contain 2, 3, or 4 sets of
SensaTank II Detector Cells Detectors Cells.
1. On each tank, find and mark FLAT points where the tank 4. If your kit contains modular plugs, be sure connections
VOLUME (not height) equals 1/3, 2/3, and Full. Maximum match color-coding in the drawing.
distance between volume points is 15" (38cm), but the 5. To test wiring, place thumb over “+” on back of a Detector
points DO NOT need to be directly above each other. Cell to activate it. Test console to be sure it is reading that
2. At volume points, clean tank surface with isopropyl alcohol cell (see front of this sheet for operating instructions).
(do not use rubbing alcohol because it contains lanolin). 6. When wiring is complete, fit display console into hole and
3. Unwrap Detector Cell cable. use it as template to drill four 3/32" (2.3mm) pilot holes for
4. Detector Cells can be attached to volume points in any the mounting screws.
order. One at a time, remove adhesive backing and stick 7. Use suitable screws to fasten display console to backing
Detector Cells to FLAT points on tank wall. surface.
IMPORTANT:
Detector Cells must fully contact the tank wall, so press hard
over entire Detector. Air gaps will negatively affect operation.

TouchSensor Technologies, LLC


203 North Gables Blvd.
Wheaton, IL 60187
www.touchsensor.com
(630) 221-9000
Proud Members of:
FMCA (Family Motor Coach Association)
RVIA (Recreation Vehicle Industry Association)
NMMA (National Marine Manufacturers Association)
©2005, TouchSensor Technologies, LLC
Instruction 600339, Rev. B 2005/10

Mirus™ is a registered trademark of TouchSensor Technologies, LLC. Protected under U.S. Patent Numbers 5,594,222; 6,310,611; 6,713,897 and others pending.

You might also like