You are on page 1of 2

20, 25, A20 and A25 Series VAC-96023B

Revised 03-06
Catalog Section 05
Vacuum Swichgage® instrument
20 Series 2 and 2-1/2 in. (51 and 64 mm) Dial
■ Combination Indicating Gage and
Limit Switch
■ Critical Vacuum Limit Switches Are

** Visible and Adjustable (Most Models)


■ Switch Can Activate Alarms and/or

Shutdown Equipment
25 Series
■ Monitor Engine Load

Description A vacuum tubing kit (V5179) is available for all Adjustable Limit Contacts:
The 20 Series (2 inch/51 mm dial) and the 25 models to help reduce pulsations. The kit includes 2-SPST contacts; pilot- duty only, 2 A @
Series (2-1/2 inch/64 mm dial) Swichgage 48 inches (1.2 m) of copper tubing and two com- 30 VAC/DC. Contacts are gold flashed silver.
instruments are diaphragm-actuated, vacuum- pression fittings. Specify tubing kit V5179. Limit Contact Adjustment: by a 1/16 in. hex
indicating gages, with built-in electrical switch- wrench.
es. These switches are used for tripping alarms Applications Limit Contact Wire Leads (20 and 25
and/or shutdown devices. Commonly used to measure loading of spark Series):
The 20 and 25 series gage mechanism is ignition engines through intake manifold vacu- 18 AWG (1.0 mm2) x 12 in. (305 mm).
enclosed in a steel case coated to resist corrosion. um. Also can serve as overspeed protection Limit Contact Terminals: A20 Series number 4
The A20 and A25 series gage has a polycarbon- from sudden loss of load on these engines. Use screw terminals; A25 Series number 6
ate case and is sealed from the environment. anywhere the vacuum source is compatible screw terminals.
All gages feature a polycarbonate, break-resistant with port materials. Unit Weight
lens and a polished, stainless steel bezel to help 20 Series: 8 oz. (0.23 kg).
protect these rugged, built-to-last instruments. Specifications 25 Series: 11 oz. (0.31 kg).
The gage pointer acts as a pressure indicator Dial: White on black, dual scale; U.S.A. A20 Series: 6 oz. (0.17 kg).
and as one switch pole which completes a cir- standard scale is Inches of Hg/kPa. A25 Series: 10 oz. (0.28 kg).
cuit when it touches the adjustable limit con- Case (mounting clamp included): Unit Dimensions
tact. Contacts have a self-cleaning motion to 20 and 25 Series: Plated steel. 20 and A20 Series: 3 x 3 x 3 in. (76 x 76 x 76
ensure electrical continuity. A20 and A25 Series: Polycarbonate/glass mm).
Gage-only models, without contacts filled. 25 and A25 Series: 4-3/4 x 4-3/4 x 2-3/4 in.
(Murphygage® instruments), are also available. Bezel: Polished stainless steel, standard; others (121 x 121 x 70 mm).
A pulsation dampener (PD2160) is included are available (see How to Order). Warranty
with each Swichgage to help eliminate pointer Lens: Polycarbonate, high-impact. A limited warranty on materials and workmanship is
flutter. When monitoring intake manifold vacu- Process Connection: 1/8-27 NPTM brass. given with this FW Murphy product. A copy of the
warranty may be viewed or printed by going to
um, the PD2160 is mounted in the manifold. Sensing Element: Beryllium copper diaphragm. www.fwmurphy.com/support/warranty.htm
The PD2160 has a 1/8-27 NPT connection. Gage Accuracy: ±2% of scale in operating
range (mid 1/3 of scale). **Products covered by this bulletin comply with EMC
Council directive 89/336/EEC regarding electromagnetic
compatibility except as noted.

VAC-96023B page 1 of 2
Dimensions
20 Series Models 25 Series Models
2-15/64 in. 2-7/32 in. 3-1/8 in. 2-1/8 in.
(57 mm) (56 mm) (79 mm) (54 mm)

1/8-27
NPTM
2-1/32 in.
1/8-27 2-5/8 in.
(52 mm)
Mounting NPTM (67 mm)
Clamp

Wire Mounting
Lead Clamp

Wire
Contact Adjustments 1-5/16 in. Lead
1/16 in. hex (33 mm)
Contact
2-1/16 in. (52 mm)
Adjustments
Mounting hole dia. 2-11/16 in. (68 mm) 1-3/8 in.
1/16 in. hex
Mounting hole dia. (35 mm)

A20 Series Models A25 Series Models


2-1/4 in. 2-9/64 in. 2-29/32 in. 1-51/64 in.
(57 mm) (54 mm) (74 mm) (46 mm)

1/8-27
NPTM 1/8-27
2-1/32 in.
(51 mm) NPTM 2-5/8 in.
Mounting
Clamp (67 mm)
Mounting
Clamp

Contact Adjustments
1-27/64 in.
1/16 in. hex (36 mm)
Contact
2-1/16 in. (53 mm) Adjustments 1-27/64 in.
2-11/16 in. (68 mm)
Mounting hole dia. 1/16 in. hex (36 mm)
Mounting hole dia.

How to Order
To order, use the diagram below. List options in ascending alphabetical order (A-Z). Example: 20V-I-30.
Order the vacuum tubing kit as a separate item (specify V5179).

____ – ____ – ____

Base Model Options†


20V B1 = Black bezel I = Illumination (20 Series Only) Range††
25V B2 = Bezel 05051857 (was “HP”) K = Knob adjusting face contact 30 = 0 to 30 in. Hg (0 to -100 kPa)
20VG B3 = Bezel 05051836 (was “HBB”) ††Select scale so your normal operating
25VG D = Direct mount vacuum is in the middle half of the scale.
A20V EX = Explosion-proof
A25V EL = Explosion-proof less case
A20VG F = “FS” contact (includes “ES” as appropriate)
A25VG †Options not available on all models or configurations.

In order to consistently bring you the highest quality, full featured products, we reserve the right to change our
specifications and designs at any time. MURPHY, the Murphy logo, and Swichgage® are registered and/or com-
www.fwmurphy.com mon law trademarks of Murphy Industries, Inc. This document, including textual matter and illustrations, is copy-
918.317.4100 Email: sales@fwmurphy.com right protected by Murphy Industries, Inc., with all rights reserved. (c) 2006 Murphy Industries, Inc.

In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time.

VAC-96023B page 2 of 2