Operation and Setup
Description
Power On/Off
Unit is powered on by connecting the power cable and power off by disconnecting
power cable
Control Interface
The unit maybe connected directly to a PC through and Ethernet crossover cable.
When directly connected to a PC the unit must be setup using a static IP address a
nd the PC must also be configured with a static IP address
address.
1
Network Connection Setting
1.Check your network connection for Ethernet port which was connected to laptop.
2. Set PC static IP address to “192.168.5.1”
• Please make sure yyou are able to ping
p g scanner IP address: 192.168.5.2
• Ping reply messages represent connection has been established
2
Port Setting
3
New Task
* “Scanner 1” section on the left bottom side of XCAL main window would changed
g its color to Blue.
4
RF Setting
5
Data Measurement Setting
6
Scanner parameters
Measurement Enable:
RS: RSRP (dBm), RSRQ (dB) – When this box is checked the Reference Signal Received Power and Reference Signal Rec
eived Quality will be included in the measurement
Detection Mode
D i M d
ASYNC – Detection is attempted without attempting to synchronizing to the downlink signal
SYNC – Detection is performed following the synchronization of the downlink signal to a known standard such as GPS
Robust – When working in an environment with increased noise and interference, Robust mode will improve
detection by performing a more detailed analysis of the signal. Robust mode is slower than ASYNC or the SYNC
yp g y g
Modes.
Number of TX Antennas – Specifies the number of transmit antennas being used by the base station
Observation to Average – The number of observations that must be detected before reporting the channel.
PSCH Detect Threshold – The signal level below which the Primary Synchronization Channel (PSCH) decoded data is not retu
rned. This threshold is enabled when Measurement Enable, SCH is selected, otherwise it has no effect. The default value
for this setting is – 10dB
SSCH Detect Threshold – The signal level below which the Secondary Synchronization Channel (SSCH) decode data is not ret
urned. This threshold is enabled when Measurement Enable, SCH is selected, otherwise it has no effect. The default value
is ‐6 dB
RS Detect Threshold
RS Detect Threshold – The signal level below which the RS decoded data is not returned. This threshold is enabled when M
The signal level below which the RS decoded data is not returned This threshold is enabled when M
easurement Enable, RS is selected, otherwise it has no effect. The default value for this setting is ‐20 dB.
7
PCI Setup
8
PCI Setup
PCI Group – Allows you to select the PCI Group.
Count – The number of pairs in the unlabeled search field
Unlabeled field – This field contains the PCI/PCI Group pairs that will be searched for during the survey. Only
data on these pairs will be returned. This field can have a maximum of 127 pairs.
9
Save/Load Setting
10
Start Scan
2. Click Bar graph to check detail measurement result for corresponded PCI
11