You are on page 1of 125

HOUSING & DEVELOPMENT BOARD

SINGAPORE

SCHEDULE OF RATES
(BUILDING WORKS)
SCHEDULE OF RATES FOR TERM CONTRACT FOR BUILDING MAINTENANCE
WORKS TO VARIOUS HDB INDUSTRIAL ESTATES

PREAMBLES PAGE

General Preambles 1 of 19

Particulars Preambles to Various Trades 4 of 19

SCHEDULE OF RATES

Excavation 1

Concrete Work 2

Brickwork & Blockwork 5

Floor Finishes 7

Carpentry & Joinery 9

Ironmongery 13

Structural Steelwork & Metalwork 19

Signages 30

Roofing 32

Wall & Ceiling Finishes 37

Painting & Decoration 40

Glazing 43

Fire Equipment 43

Reinstatement of Water/Electricity Work 44

Concrete Repair 45

Water Seepage/Leakage 46

Water/Building Component Test 48

Miscellaneous 48

Sanitary 49

Daywork 91

Supplementary 94
Page 1 of 19

SCHEDULE OF RATES FOR TERM CONTRACT FOR BUILDING MAINTENANCE


WORKS TO VARIOUS HDB INDUSTRIAL ESTATES

GENERAL PREAMBLES

INTRODUCTION

1 The clauses in the General Preambles shall apply to all work items contained
in the Standard Schedule of Rates.

2 The Particular Preambles to each Trade shall be read in conjunction with the
respective Trade in the Standard Schedule of Rates.

3 All rates include the allowances for complying with the General and Particular
Preambles.

4 All rates contained in the Standard Schedule of Rates are fixed basic rates (in
Singapore Currency) and no amendment whatsoever shall be made to such
rates. The tenderers shall be deemed to have closely studied all rates
contained herein and duly noted their implications.

5 All rates contained in this Standard Schedule of Rates are exclusive of any
Goods and Services Tax. Any such Goods and Services Tax shall be borne
by the HDB as and when the same becomes due and payable.

6 All work, materials and goods described in this Standard Schedule of Rates
shall be of the respective kinds described in the Contract and in accordance
with the instructions of the Superintending Officer or the Superintending
Officer's Representative.

7 Headings to groups of items shall be read as part of the descriptions of the


items to which the headings apply.

8 Where brand/trade names are given in the descriptions, they are solely
intended for fixing the rates of the items. The products and materials to be
used in the contract shall be governed by the specifications, Drawings and
other documents forming the contract (and not this Schedule of Rates).
Page 2 of 19

INTRODUCTION (CONT’D)

9 Description of Works and Inclusions

Unless specifically stated otherwise, the following shall be deemed to be


included in the description of the item of work:-

a) Labour and all costs in connection therewith including the labour in


fabricating, assembling, setting, fitting and fixing of materials and
goods in position.

b) Materials and goods including materials required for lapping, jointing


and the like and all costs in connection therewith such as delivery,
unloading, storing, returning of packings, handling, hoisting and
lowering.

c) Preparing surfaces to receive work.

d) Protecting materials and work.

e) Waste of materials.

f) All cutting and waste.

g) Use of construction equipment, tools, vehicles and all costs in


connection therewith.

h) Cleaning up on completion and making good all work disturbed.

i) General requirements set out in the Specifications, Drawings and


other documents forming the Contract.

j) Establishment charges, overhead and profit.

k) Safety provisions required by HDB Safety Units and statutory


requirements.

l) Urgent mobilization of labour, plants and equipments in the shortest


possible time when instructed by So Representative.

m) Dismantle and removal of existing fittings/works affected by the new


installation including make good disturbed areas, cart away and
disposal unless otherwise specified.

n) ENVI dumping fees.

10 Unless otherwise stated, all work shall be measured net and for work
measured by area, it shall be measured net and flat on the surface as fixed in
its place.

11 Unless otherwise stated, pipes are described by their internal diameters.


Page 3 of 19

INTRODUCTION (CONT’D)

Description of Works and Inclusions (Cont’d)

12 Where minimum deductions of voids are dealt with in this document they shall
refer only to openings or voids which are within the boundaries of measured
area. Openings or voids which are at the boundaries of measured area shall
always be the subject of deductions irrespective of size.

13 Stagings and scaffoldings erected as instructed and approved by SO


Representative shall be measured and paid separately unless otherwise
specified.

14 Unless otherwise stated, the term “as specified” means as specified in any of
the documents forming part of the Contract.

15 The following abbreviations are used for the units:-

m - Linear metre
m2 - Square metre
m3 - Cubic metre
no - Number
kg - Kilogram
ton - Tonne
pr - Pair
sht - Sheet
ltr - Litre
hr - Hour

16 The “GENERAL PREAMBLES” and the “PARTICULAR PREAMBLES TO


VARIOUS TRADES” shall also be applicable to the Supplementary Schedule
of Rate.
Page 4 of 19

PARTICULAR PREAMBLES TO VARIOUS TRADES

1.0 EXCAVATION

Definition of Ground
1.1 Ordinary ground:- includes spoil or rubbish of every description, rubbish tip
material etc, sand gravel, decomposed granite, red or white earth, loamy or
gravelly clay, gravelly laterite, mud, bog or any other formation of pick and
shovel and at any depth.

Description
1.2 The description of each item of excavation shall be deemed to include
excavating around foundation, piles and confined areas, getting out, removing
of bakau piles, trimming, levelling and compacting bottoms of excavations,
keeping sides plumb and planking and strutting.

Measurement
1.3.1 The measurement of all excavations and subsequent disposal shall be those
before excavating. The increases in bulk and any extra excavation required
for earthwork support, planking and strutting and formwork for concrete shall
be deemed to be included in the rates.

1.3.2 No allowance for working space shall be made in the measurement of all
excavation unless the method of construction requires workmen to operate
from the outside of the structure. In such cases, a working space of 600mm
shall be measured from the external face of the structure.

1.3.3 Filling shall be measured as equal to the void to be filled. Any thickness
stated shall be deemed to be after compacting.

Rate
1.4.1 Rates for each item shall be held to include for keeping all excavation free
from water and site dry pumping or bailing if required and providing any
temporary drains required.

1.4.2 Rates shall be held to include for engaging licensed cables/services detection
worker to carry out all cable/services detection works prior to the
commencement of excavation works and any piling/penetration works.

Breaking-Up/Hacking
1.5 Rates shall include cutting to concrete/premix surfaces by hand held cutting
tools to a required depth as instructed by S.O. Representatives prior to
hacking.
Page 5 of 19

2.0 CONCRETE WORK

Rate
2.1 Rates for each item of concrete shall be held to include the following:-

a) Forming, cutting grooves, chases, mortices, holes and making good


any other sundry items of a like nature.

b) Extra labour for laying to falls, or cambers and preparing surfaces to


receive screeds or pavings also to be included.

c) All tests on concrete, cement and aggregate etc, as required and


compliance with the strengths as specified.

d) Tamping and/or vibrating to give thorough compaction; working


between and around reinforcements.

e) Laying on any type of sub-base; preparing and leaving surfaces to


receive screeds or paving.

f) Trowel smooth to surface with steel trowel or brush finished.

Deduction
2.2 No deduction shall be made in the measurement of concrete work for:-

a) Voids of 0.05 cubic metre or less.

b) Volume of the reinforcement and steelwork.

c) Openings in walls, floor, roof slabs and the like of 0.10 square metre
or less.

2.3 Reinforcement

Description
2.3.1 The description of each item of reinforcement shall be deemed to include:-

a) Allowances in the weight of reinforcement for rolling margins.

b) All cleaning, cutting, bending, fabricating, placing, tying and the


provision of all necessary distance blocks, tying wires, spacers or
chairs, temporary fixings and supports.

c) Brushing and cleaning all reinforcement free of rust, dust, mill scale,
dirt, oil and any other deleterious matter.
Page 6 of 19

2.0 CONCRETE WORK (CONT’D)

2.3 Reinforcement (Cont’d)

Measurement
2.3.2 The conversion factor for the various steel reinforcement bars shall be as
follows:

6mm diameter - 0.222 kg/m


7mm diameter - 0.302 kg/m
8mm diameter - 0.394 kg/m
9mm diameter - 0.499 kg/m
10mm diameter - 0.616 kg/m
13mm diameter - 1.042 kg/m
16mm diameter - 1.579 kg/m
20mm diameter - 2.466 kg/m
22mm diameter - 2.984 kg/m
25mm diameter - 3.854 kg/m
28mm diameter - 4.834 kg/m
32mm diameter - 6.313 kg/m

2.4 Fabric Reinforcement


Rate
2.4.1 Rates for each item of fabric reinforcement shall be held to include for extra
material at laps, tying wires and all bending, cutting and notching around
obstruction. Only the net area covered shall be measured and no deduction
shall be made for opening less than 1.00 square metre.
2.5 Formwork
Description
2.5.1 The description of each item of formwork shall be deemed to include:-

a) All necessary boardings, supports, erecting, framing, cutting,


perforations for pipes, angles, cleaning, wetting and treatment with
mould oil, mould liquid or limewhite and the like.

b) All splayed edges, notchings, allowance for overlaps and passings at


angles, battens, strutting, bolting, wedging, easing, striking and
removal.

Measurement
2.5.2 Formwork shall be measured to the surface of work sloping more than 15
degree from the horizontal.
Page 7 of 19

2.0 CONCRETE WORK (CONT’D)

2.5 Formwork (Cont’d)

Deduction
2.5.3 No deduction shall be made in measurement of formwork for:-

a) Openings less than 1 square metre.

b) Intersection of main and secondary beams.

c) Intersection of beams and stanchion casing or columns.

2.6 Unless otherwise stated, rates for concrete, reinforcement and formwork shall
be applicable to all work irrespective of locality, positions, shapes and height.

2.7 Precast Work

Description
2.7.1 The description of each item of precast work shall be deemed to include
concrete, reinforcement, formwork including the formation and filling of
pockets, holes, chases and recesses for anchors, bolts and the like, grouting,
pointing of joints, surface finishes, delivery, unloading, hoisting, erecting,
fixing including all necessary temporary erection gear, bracing and working
platforms.

2.8 Precast Concrete Vent

Measurement
2.8.1 The measurement of precast concrete vents shall be taken by volumes
without deduction of voids.

2.9 Surface Water Channels

Rate
2.9.1 Rates for each item of surface water channels shall be held to include for all
angles, intersections, ends, outlets and extra labour and material for forming
grooves or rebates to sides.

Breaking-Up/Hacking
2.10 Rates shall include cutting to concrete surfaces by hand held cutting tools to a
required depth as instructed by S.O. Representatives prior to hacking.
Page 8 of 19

3.0 BRICK AND DRAINAGE WORK

Rate
3.1 The rates for each item of block, brickwork shall be held to include for all
special made blocks, bricks and in-situ concrete in lieu, all rough and fair
cuttings, oversailing and receding courses, rough relieving and discharging
arches, wedging and pining, raking out joints for and pointing flashings,
bedding plates, bedding and pointing of frames, parging and coring flues,
labour eaves filling, plumbing angles, forming square and rebated reveals, cut
squints or birdsmouths, notches, forming, leaving or cutting chases, holes and
mortices, cutting and pining and making good and any other sundry items of a
like nature.

3.2 Rates for blockwork and brickwork shall be applicable to all work irrespective
of positions, patterns, shapes and height.

Deduction
3.3 Deductions shall be measured the net sizes of the openings and recesses,
including the extra width or rebated reveals. No deductions shall be made for
openings of 0.50 square metre or less.

3.4 Deductions shall be made for strings, sills, lintols and the like only when
exceeding 100mm in height.

4.0 FLOOR FINISHES

Description
4.1 The description of each item of floor finishes shall be deemed to include all
temporary rules, temporary grounds, temporary screeds and the like, cutting
holes, notching and the like, all normal bedding and pointing materials,
providing all necessary samples, cleaning down and making good around
pipes, sanitary fixtures and the like, work in narrow widths and small
quantities in areas interrupted by seatings, channels and the like, all internal
angles, quirks, grooves, throats, drips, coves and rounded external angles
not exceeding 25mm radius, angles, stops, intersections, fair ends junctions,
wreathed corners and the like on cornices, mouldings, enrichments, coves,
skirtings, gutters, channels, strings, kerbs and similar or other sundry items
of a like nature.

4.2 The description of each item of floor finishes shall be deemed to include
protecting surfaces from the weather or building operations.

Screed/rendering shall include for towelling smooth with steel trowel or brush
finished.

Rate
4.3 Rates for each item of skirtings, risers, moulded edges, channels, curbs and
the like shall be held to include for all short lengths, formed, cut and purpose
made angles, junctions, end, necessary UPVC trimming pieces, etc and
making good and any other sundry item of a like nature.
Page 9 of 19

4.0 FLOOR FINISHES (CONT’D)

Deduction
4.4 No deduction shall be made for openings of 0.50 square metre or less.

Breaking-Up/Hacking
4.5 Rates shall include cutting to concrete surfaces by hand held cutting tools to a
required depth as instructed by S.O. Representatives prior to hacking.

5.0 ROOFING

Description
5.1 The description of each item of roofing shall be deemed to include:-

a) All laps, straight, skew and circular cutting at eaves, verges, top
edges, abutments, valleys and hips, cutting holes for pipes, nails,
screws, clips, pellets, straps and the like.

b) Chasing the structure for burning-in or tucking in edges of coverings,


flashing and the like.

c) Holes in coverings, underbeds and insulations for pipes, standards


and the like and making good.

Deduction
5.2 No deduction shall be made for voids of 0.50 square metre or less.

5.3 Membranes System and Panel Roofing System

Rate
5.3.1 Rates for Waterproofing Membranes System and Panel Roofing System shall
be held to include for narrow widths, small quantities, temporary rules,
covering up, protecting after laying and cleaning on completion, all labour to
form arrises, fair edges etc., all cuttings and working around pipes, dress
down at eaves to form drips or carried up at abutments to walls, pipes,
parapets, skirtings, concrete curbs etc. and the like.

5.4 Profiled Sheet Roofing

Description
5.4.1 The description of each item of profiled sheet roofing or cladding shall be
deemed to include all cutting at square and raking abutments, top edges,
bedding and pointing eaves fillers, verges, cutting and fitting and making good
around outlets, pipes and any other sundry items of a like nature.
Page 10 of 19

6.0 CARPENTRY AND JOINERY

Description
6.1 The description of each item of carpentry work shall be deemed to include all
cutting, notching, boring, sinking, pelleting, fitting, trimming, mitring, halving,
morticing, tenoning, dovetailing, scarfing, wedging and all ends, splayed
edges, short lengths and temporary supports and any other sundry of a like
nature and also all labour in forming, drilling for bolts and fixing in position
complete with nails, screws or adhesives.

6.2 The description of each item of joinery work shall be deemed to include all
nailing, gluing, screwing, plugging, cutting, notching, holes, housing ends,
mitring ends and shaped ends, angles, junctions, heading joints, short
lengths, tongued angles, splayed or rounded edges, chamfers, rebates,
grooves and any other sundry items of a like nature including stops and
working cross-grain, fitting and hanging and the like.

6.3 Nominal sizes are stated for wrot timber and an allowance of 2.5mm is
permitted for each wrot face.

6.4 Rates for windows and doors include hanging and fixing.

6.5 Where ironmongery is included in the description of doors, it shall be deemed


to include hinges, floor springs, door gears, locks, latches, catches, bolts,
closers, holders, padlocks, stoppers, push-bars and plates, pull bars and
handles, kickplates, locking eyes and the like as specified.

7.0 IRONMONGERY

Rate
7.1 Rates for each item shall be held to include for supply, delivery to site and
fixing complete with all matching screws of the same finish as ironmongery,
nails, pins or brads, cutting sinking and boring and morticing as required,
oiling and easing and adjusting all moving parts, taking off and refixing after
painting where necessary and handing 3 keys properly labelled to the
Superintending Officer or the Superintending Officer's Representative etc
unless otherwise described.
Page 11 of 19

8.0 STEEL AND IRON WORK

8.1 Steel Work

Description
8.1.1 The description of each item of steel work shall be deemed to include:-

a) Allowances for rolling margins and the weight of welding materials.

b) Shop and site fabrication including drilling, cutting (including holes and
openings for other trades), notching, splicing, riveting, bolting,
machining ends and bearings, delivery, unloading, landing, hoisting,
erecting, fitting and fixing in position.

c) Provision of all necessary construction equipment, temporary bracing


supports and the like required for erection, providing samples and
tests required by the specification, the inspection of welds including
the use of any special radio-graphic techniques.

d) Bolts and Nuts (including anchor bolts/studs) and any type of washer
which may be required.

e) Preparation of shop Drawings.

Deduction
8.1.2 No deduction shall be made for drillings, holes, notchings, splay cuts and the
like.

Measurement
8.1.3 Weights stated shall be net theoretical weights.

8.1.4 Steel sections and plates in connections or fitted stiffeners, column cap and
base plates, rigid frame bases and butt plates, purlins, girts, eaves, fascias
and similar cleats or brackets attached to trusses, lattice girders and open
web joists and plates, including chequered plates in landings, treads and
risers and similar items shall be weighted at net dimensions.

8.1.5 Irregular, including circular shaped plates shall be weighted at the smallest
size rectangles from which they can be cut; regular and triangular shaped
plates shall be weighted at net dimensions.

8.1.6 Half or other parts of steel sections in connections shall be weighted at half
the weight of the section from which they have been cut when equal to or less
than half the section and at the full weight of the section from which they have
been cut when greater than half the section.
Page 12 of 19

8.0 STEEL AND IRON WORK (CONT’D)

8.2 Metal Work

Description
8.2.1 The description of each item of metalwork shall be deemed to include:-

a) Allowances for rolling margins and the weight of welding materials.

b) Cutting, notching, mitring, welding, riveting, bolting, fabricating,


drilling, delivery, unloading, handling, assembling, hoisting, fitting and
fixing in position, bedding, filling in solid, polishing and pointing
including necessary lugs or other attachments.

c) Protection such as wrapping finished work with paper, coating with


grease or carrying out such other protective measures as may be
required and removing and cleaning on completion.

d) Providing samples and testing as required.

e) Preparation of shop Drawings.

Deduction
8.2.2 Weights stated shall be net theoretical weights. No deduction shall be made
for notches, holes and the like.

9.0 WALL AND CEILING FINISHES

Rate
9.1 Rates for each item shall be deemed to include the provision of keys to
receive finishes, all temporary rules, temporary grounds, temporary screeds
and the like, cramps, dowels, ties, special metal supporting brackets and the
like, cutting holes, notching and the like, masking, labour to internal angles
other than coved angles, making good around pipes, sanitary fixtures and the
like, work in narrow widths and small quantities, joints between different types
of work, joints between new and old work, internal angles, fair edges, rounded
or chamfered edges or angles, quirks, grooves, V-joints, groin points and
other intersections of curved surfaces, rounded coves and external angles not
exceeding 25mm radius, necessary UPVC trimming pieces, mitres, stops and
the like on cornices, mouldings, architraves, coves, skirtings, gutters, strings
and all making good and any other sundry items of a like nature.

9.2 Rates for each item shall also be deemed to include protecting surfaces from
the weather or building operations.

9.3 Rates for each item of wall tiling shall be held to include for narrow widths and
small quantities, fittings around air bricks, pipes and the like and any other
sundry items.
Page 13 of 19

9.0 WALL AND CEILING FINISHES (CONT’D)

9.4 Rates for each item of terrazzo shall be held to include for narrow widths and
small quantities, and for all temporary rules, internal angles, arises, joints
between different types of terrazzo, quirks and all making good and any other
sundry items of a like nature on in-situ terrazzo, fitting around air bricks, pipes
and the like and any other sundry items of a like nature on precast terrazzo.

Deduction
9.5 No deduction shall be made for openings of 0.50 square metre or less.

Measurement
9.6 In the measurement of plastering, no deduction shall be made for casings for
pipes under 300mm wide or angles which are finished in a different material if
these do not exceed 100mm girth.

9.7 "Within the building" shall mean surfaces within the internal of buildings/flats,
corridors, staircases and the like which normally do not entail scaffolding or
mechanical cradles to carry out the works.

9.8 "External face of building" shall mean surfaces such as gable end walls,
front/back external walls and any other surfaces which are constantly
exposed to weather and/or which normally require the use of scaffolding or
mechanical cradles to carry out the work.

9.9 Work shall be deemed to be executed when scaffolding has been provided
during the course of construction. Should scaffolding be required separately
just to execute the work, it would be paid as an extra item.

10.0 SANITARY, WATER AND GAS INSTALLATION

Description
10.1 The description of each item of pipework shall be deemed to include:-

a) All short lengths, joints in the running lengths, joints to all branches,
tees, sockets, sleeves, connectors, backnuts, nipples, standard pipe
framings or supporting clips, saddles, fastening brackets, holderbats,
straps and the like.

b) Giving notices.

c) Complying with all requirements of the relevant authorities, paying


fees and the like in connection with the installations and preparing and
submitting Drawings for approval if required.

d) Removal of existing if necessary unless otherwise specified.


Page 14 of 19

10.0 SANITARY, WATER AND GAS INSTALLATION (CONT’D)

10.2 Drain Pipes


Pipes for soil drains shall be sound salt-glazed unglazed stoneware pipes free
from breakage, distortion or fire cracks or approved UPVC pipes and of sizes
shown. All drains under buildings shall be of Spun cast iron pipes complying
with BS 4622:1970 Class 2 laid on concrete bed. Drain pipes shall be laid in
straight lines to even falls. Only flexible jointed pipes approved by the
Sewerage Department, shall be used for drain-line pipes.

Soil, Waste and Vent Pipes


10.3 The soil, waste and vent pipes are to be of cast iron (SS 33:1975 OR UPVC
SS 213:1979) of the sizes to match existing or as directed. All jointing and
fixing requirements shall be in strict accordance with the manufacturer's
instruction.

Fittings
10.4 All sanitary fittings shall be of type currently approved by the Board and the
relevant local authorities.

Sample shall be submitted before hand if required.

Squat Pan
10.5 Squat pans shall be of vitreous China complying with British Standards
3402:1964, of approximate dimensions 660 x 254 x 330 mm deep white
glazed washed down type with "P" or "S" traps, cleaning eye and stopper.

Pans shall be of pattern and quality currently approved by the Ministry of the
Environment.

Each pan shall be completed with approved high level flush cistern with
40mm diameter P.V.C. or galvanised iron flush pipes.

Flush pipes shall be held at mid height by holderbat securely fixed to wall.
Galvanised pipes shall be provided with 150mm high 16mm thick protective
cone at base of 1:3 cement mortar.

Flushing Cisterns
10.6 Flushing cisterns shall be of type currently approved by HDB, 9.0/4.5 litres
dual action flushing cistern or approved in which pull chain will release either
4.5 or 9.0 litres of water when desired. The levers shall be of aluminium alloy.

White Glazed Fireclay Sinks


10.7 Glazed fireclay sinks where required shall be 610mm x 450mm x 200mm
white fireclay "Belfast" or other approved pattern fixed on cantilever brackets
complete with traps, outlet pipes, and rubber or vulcanite plugs.
Page 15 of 19

10.0 SANITARY, WATER AND GAS INSTALLATION (CONT’D)

Water Installation
10.8 All pipes and pipefittings shall be approved by Water Department, PUB
unless otherwise specified.

(A) Ductile Iron Pipes for Water Supply

All ductile iron pipes and fittings for water installation shall comply with
BS 4772:1988 and ductile iron flanges shall comply with BS 4504.

These pipes shall be cement mortar lined carried out in accordance


with the relevant clauses in BS 543:1981. The lining shall be applied
centrifugally by spinning the pipe in an approved plant and shall
adhere firmly to the internal surface of the pipe. Lining shall also
apply to fittings by means of approved process. The cement mortar
shall consist of equal volume of Portland Cement, granite dust and
sand correctly measured. The maximum grain size of sand or granite
dust shall be clean, free from clay, animal, vegetable or other foreign
matter.

The internal surface of pipes shall be thoroughly cleaned and free


from rust, scale or other deposit immediately before lining. The
thickness of the lining shall be 6mm, tolerance +3mm, -0mm for
100mm nominal diameter pipe.

The lining shall adhere firmly to the inside of the pipe and shall be
finished smooth, even and free from any cracks or blemishes. The
lining shall be continuous from spigot and to the beginning of the
socket for pipes with spigot and socket joint and shall be continuous
from face to face of flanges in the case of flanged pipes.

(B) UPVC (Service/Distributing Pipes and Fittings) Water Pipe

(i) All the service/distributing pipes and fittings shall be of


unplasticised P.V.C. Corrosion resistant pipes complying with
SS 141:1976 Class E and fittings complying with SS 174:1977
with its latest amendments and all tests as required by Water
Department, PUB.

Supply and fix all the UPVC pipes to the sizes and locations as
shown in the drawings. The diameter shown shall be of
norminal size. The mean tolerances on outside diameter shall
conform to SS 141:1976.

The pipe walls shall be homogenous throughout and the


internal and external surfaces shall be clean, smooth and
reasonably free from grooves, blisters, wrinkles, dents and
heat marks. The ends shall be cleanly cut and square with the
axis of the pipe.
Page 16 of 19

10.0 SANITARY, WATER AND GAS INSTALLATION (CONT’D)

10.8 Water Installation (Cont’d)

(B) UPVC (Service/Distributing Pipes and Fittings) Water Pipe (CONT'D)

(ii) The method of fixing UPVC pipes to UPVC pipes shall be as


follows:-

(a) All pipes must be sawn square.

(b) All swarf, burr and sharp edges shall be removed after
cutting.

(c) The pipe end and the socket in pipes or fittings must be
cleaned with cleaning fluid or methylated spirit and
allowed to dry. No sand paper is allowed for cleaning
the pipes and fittings.

(d) The spigot shall be marked with a pencil line at a


distance to the depth of the socket in fittings or to the
depth of sockets formed in pipe.

(e) All pipes ends and internal face of socket shall be


thoroughly coated with solvent and allowed to dry.
Apply the second coat of solvent as before and insert
the pipe into socket immediately. Surplus solvent must
be removed from the top of socket using a dry cloth.

(f) After jointing the joint shall be held firmly for a period of
30 seconds and not disturbed for at least 5 minutes.

(g) All joints must be jointed with suitable sockets


recommended by the pipe manufacturer. In situations
where a pipe and socket joint is not possible, a
coupling shall be used.

(h) No socket belling shall be allowed when joining UPVC


pipes.
Page 17 of 19

10.0 SANITARY, WATER AND GAS INSTALLATION (CONT’D)

10.8 Water Installation (Cont’d)

(B) UPVC (Service/Distributing Pipes and Fittings) Water Pipe (CONT'D)

UPVC adoptors shall be used for jointing of UPVC pipes to


other materials and also to the pipe manufacturer's
recommendation or as follows:-

(a) An approved epoxy compound shall be used. A


caulking ring or bush shall be glued to the end of the
UPVC pipe.

(b) For all jointing assemblies the solvent weld cement


method shall be used.

All fixing work shall be carried out in strict accordance with the
pipe manufacturer's instructions.

(iii) Pipes shall be well supported by UPVC shackle clips. These


supports shall sufficiently allow free movement of the pipe
during temperature changes.

Maximum Maximum
Horizontal Support Vertical Support
Nominal Size Spacing Spacing
(mm) (mm) (mm)

10 400 800
15 400 1000
20 500 1200
25 600 1400
32 700 1600
40 800 1800
50 900 1800
65 & Above 1000 1800
Page 18 of 19

10.0 SANITARY, WATER AND GAS INSTALLATION (CONT’D)

10.8 Water Installation (Cont’d)

(C) Stainless Steel Water Pipes

All Stainless steel Water pipes, fittings and accessories shall be


approved by Water Department, PUB and to the requirement of BS
4127:Part 2:1972 with its latest amendments.

The internal and external surfaces of the pipes and fittings shall be
clean, smooth and free from defects that would impair their
performance in service. Cutting and fixing shall be in strict
accordance with the manufacturer's instructions. All stainless steel
pipes shall not be bent. Pipes shall be well supported by non-corrosive
(galvanised steel) supporting clips.

Unless otherwise specified, light gauge stainless steel pipes shall be


used for water supply.

The stainless steel pipefittings shall be of capillary or compression


fittings of copper alloy and shall comply with BC 864:Part 2:1983 and
all PUB latest requirements. Fittings of 15mm size and longer shall be
legibly marked with the marker's name or trademark.

Pipes shall be well supported by supporting clips or hangers.

Maximum Maximum
Horizontal Support Vertical Support
Nominal Size Spacing Spacing
(mm) (mm) (mm)

15 600 1200
20 - 28 600 1200
35 - 42 1200 1800
54 & Above 1200 1800

11.0 GLAZING

Rate
11.1 Rates for each item of glazier shall be held to include for cutting and rounded
edges, fixing panel pins, clips, brass screws and cup and neoprene strips
where necessary and leaving the glass clean on completion.
Page 19 of 19

12.0 PAINTING AND DECORATING

Rate
12.1 Rates for each item of painting shall be held to include for all necessary
preparation of surfaces including cleaning off, sandpapering woodwork, wire
brushing metal and leaving all surfaces free from dust, rust, grease and oil
before painting, narrow widths, etc.

Deduction
12.2 No deduction shall be made for openings of 0.50 m2 or less.

12.3 Work shall be deemed to be executed when scaffolding has been provided
during the course of construction. Should scaffolding be required separately
just to execute the work, it would be paid as an extra item.

13.0 DAYWORK

Rate
13.1 Rates shall be applicable in respect of all work executed on a day work basis.
During the continuance of such work, the Contractor shall keep proper
records of the names, occupations and working hours of all workmen
employed for such work and the quantities and descriptions of all materials
and construction equipment employed. Such records, receipts or vouchers
must be verified by the Superintending Officer or the Superintending Officer's
Representative before payment can be effected.

13.2 Rates for equipments and plants shall be deemed to include maintenance
and fuel unless otherwise specified.
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | EXCAVATION | | |
| | | | |
| A001 | Excavation oversite from ground level | m3 | 7.80 | A001
| | in ordinary ground to formation level | | |
| | including removing surplus excavate | | |
| | materials from site to contractor's own | | |
| | dumping ground. | | |
| | | | |
| | * Excavation to form trenches for | | |
| | pilecaps, foundations, beams, pier holes, | | |
| | drains etc including forming of bottom, | | |
| | part return, fill and ram and remainder | | |
| | get out and deposit at contractor's own | | |
| | dumping ground *(A002 A003) | | |
| | | | |
| A002 | Not exceeding 1.50m deep | m3 | 6.90 | A002
| | | | |
| A003 | Exceeding 1.50m deep | m3 | 12.70 | A003
| | | | |
| A004 | Extra over for item A001 to A003 using | m3 | 10.40 | A004
| | hand excavation for which mechanical | | |
| | means is not possible or practical. | | |
| | | | |
| A005 | Break-up concrete including cutting of | m3 | 72.10 | A005
| | reinforcement if any and removal of | | |
| | concrete from site to Contractor's | | |
| | dumping ground | | |
| | | | |
| A006 | Break-up concrete (including removal | m3 | 46.70 | A006
| | of reinforcements if any)/bricks broken | | |
| | to 50-70mm in size | | |
| | as hardcore including levelling, | | |
| | compacting by approved | | |
| | mechanical means including | | |
| | 50mm thick sand blinding | | |
| | | | |
| A007 | Hard-core in beds, comprising of clean | m3 | 15.60 | Bldg Sor
| | broken bricks/concrete, deposit, spread, | | | Jan 06
| | mechanically consolidated and including | | | S/n 25
| | sand blinding/topping over. | | |
| | | | |
| A008 | Good earth filling obtained from | m3 | 10.50 | Bldg Sor
| | Contractor's source and fill in layers | | | S/n 21
| | 300mm thk, including levelling and | | |
| | consolidation of earth by approved | | |
| | mechanical means. | | |
| | | | |
| A009 | Plant mixed crushed granite | m3 | 43.70 | CE SOR
| | aggregate spread and level including | | | 10.05
| | consolidation by mechanical roller. | | |
| | | | |
| A010 | Quarry waste, spread & level including | m3 | 27.70 | Bldg Sor
| | consolidation by mechanical roller | | | S/n 26
| | | | |

PAGE 1 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | EXCAVATION (CONT'D) | | |
| | | | |
| A011 | Lay clear/black plastic sheet to | m2 | 0.30 | Bldg TC
| | prepared sub-base/earth surfaces. | | | 05/06
| | | | | S/N A011
| | CONCRETE WORK | | |
| | | | |
| | * Reinforced concrete to site work, | | |
| | substructure & superstructure, with 20mm | | |
| | to 10mm granite mechanically mixed, | | |
| | working around rod or fabric | | |
| | reinforcement. (Reinforcement formwork | | |
| | measured separately). *(A012 A014) | | |
| | | | |
| A012 | Grade 20. | m3 | 94.60 | A012
| | | | |
| A013 | Grade 25. | m3 | 97.40 | A013
| | | | |
| A014 | Grade 30. | m3 | 100.10 | A014
| | | | |
| A015 | Precast concrete grade 20 in heelstones, | m3 | 442.30 | A015
| | cills and lintels including mould and | | |
| | reinforcement. | | |
| | | | | Bldg TC
| A016 | Mild steel/high tensile steel rod | kg | 1.05 | A016
| | reinforcement irrespective of size | | |
| | fabricated and laid in position. | | |
| | | | | Bldg TC
| A017 | Drill holes into concrete 50mm depth and | no | 2.40 | A017
| | apply 'HILTI-HIT-HY-150' adhesive mortar | | |
| | to bond 10mm diameter reinforcement bar. | | |
| | | | |
| | * Welded steel fabric reinforcement well | | |
| | lapped and tied at joints (measured | | |
| | nett). *(A018 A027) | | |
| | | | | Bldg Sor
| A018 | A6. | m2 | 3.70 | S/n 77
| | | | | Bldg Sor
| A019 | A7. | m2 | 4.70 | S/n 78
| | | | | Bldg Sor
| A020 | A8. | m2 | 5.80 | S/n 79
| | | | | CE Sor
| A021 | A9 | m2 | 7.10 | S/n 3.33
| | | | | Bldg Sor
| A022 | B6. | m2 | 5.80 | S/n 83
| | | | | Bldg Sor
| A023 | B7. | m2 | 6.50 | S/n 84
| | | | | Bldg Sor
| A024 | B8. | m2 | 8.50 | S/n 85
| | | | |
| A025 | D4(G) | m2 | 7.00 | A025
| | | | | CE Sor
| A026 | D4 | m2 | 6.80 | S/n 3.45
| | | | |
| A027 | No. 2210 | m2 | 8.40 | A027
| | | | |

PAGE 2 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | CONCRETE WORK (CONT'D) | | |
| | | | |
| | * Timber formwork including all necessary | | |
| | boarding, supports, erecting, framing, | | |
| | cutting, perforation for pipes, angles, | | |
| | cleaning, wetting treatment with mould | | |
| | oil, notching, laps, battens, strutting, boltin | | |
| | wedging, easing, striking & removal | | |
| | *(A028 A029) | | |
| | | | | Bldg TC
| A028 | Below ground level (Footpath, ground | m2 | 14.90 | A028
| | slab, drains, foundation etc) | | |
| | | | | Bldg TC
| A029 | Above ground level | m2 | 21.95 | A029
| | | | | Bldg TC
| A030 | 10 x 15mm(depth) expansion joint | m | 1.15 | A030
| | filled with bitumen. | | |
| | | | | Bldg TC
| A031 | 12 x 25 mm(depth) expansion joint | m | 1.70 | A031
| | filled with bitumen. | | |
| | | | | Bldg TC
| A032 | 25 x 200mm(depth) expansion joint | m | 2.75 | A032
| | filled with bitumen and filler board | | |
| | | | | Bldg TC
| A033 | 10mm wide x 40mm depth 'Quicseal 201' | m | 7.90 | A033
| | or other approved equivalent PU sealant | | |
| | | | | Bldg TC
| A034 | PVC 'L' shaped Floor Strip on cement | m | 1.80 | A034
| | mortar secured with masonry nails if | | |
| | necessary | | |
| | | | | Bldg TC
| A035 | 10mm thick polystyrene foam | m2 | 1.90 | A035
| | to expansion joint | | |
| | | | | Bldg TC
| A036 | 15mm thick polystyrene foam | m2 | 2.10 | A036
| | to expansion joint | | |
| | | | | Bldg TC
| A037 | "NH 200" neoprene compression seals | m | 82.00 | A037
| | system to expansion joints | | |
| | | | | Bldg TC
| A038 | Rake out joints to an average depth | m | 5.70 | A038
| | of 25mm to expansion joint. | | |
| | Brush out all loose joint compound and | | |
| | mortar and fill the groove solid with | | |
| | approved polyurethane sealant to | | |
| | form a continuous joint.(backer rod | | |
| | measured separately) | | |
| | | | | Bldg TC
| A039 | Rake out bitumen from suspended floor | m | 8.30 | A039
| | slab's 25mm wide expansion joint and | | |
| | refill with approved polyurethane | | |
| | sealant including backer rod. | | |
| | | | | Bldg TC

PAGE 3 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | CONCRETE WORK (CONT'D) | | |
| | | | |
| A040 | 225-250mm wide (internal) reinforced | m | 49.80 | A040
| | concrete (Grade 25) surface drain | | |
| | constructed with 75mm thick sides and | | |
| | 100mm thick bottom. All sides and bottom | | |
| | shall be reinforced with a layer of BRC | | |
| | No. B6 wiremesh. All exposed sides, | | |
| | bottoms and arises rendered smooth in | | |
| | cement mortar (1:3) including all | | |
| | necessary excavation, hard-core, sand | | |
| | blinding, formwork and PC channel laid | | |
| | to fall to an average invert depth of | | |
| | 300mm. (Breaking up of existing | | |
| | drain measured separately) | | |
| | | | | Bldg TC
| A041 | Add to (or deduct from) item A040 for | m | 5.70 | A041
| | each 50mm depth over (or under) 300mm | | |
| | depth. | | |
| | | | | Bldg TC
| A042 | 300mm wide (internal) reinforced | m | 75.40 | A042
| | concrete (Grade 25) surface drain | | |
| | constructed with 100mm thick sides and | | |
| | bottom. All sides and bottom shall be | | |
| | reinforced with a layer of BRC No B6 | | |
| | wire mesh. All exposed sides, bottom and | | |
| | arises rendered smooth in cement mortar | | |
| | (1:3) including all necessary excavation, | | |
| | hard-core, sand blinding, formwork, and | | |
| | PC channel laid to fall to an average | | |
| | invert depth 400mm. (Breaking up of | | |
| | existing drain measured separately) | | |
| | | | | Bldg TC
| A043 | Add to (or deduct from) item A042 for | m | 5.90 | A043
| | each 50mm depth over (or under) 400mm | | |
| | depth. | | |
| | | | | Bldg TC
| A044 | 50mm thick precast concrete slab over | m | 14.10 | A044
| | 225 to 300mm wide surface drain. | | |
| | | | |
| A045 | 1:3 cement and sand mortar (min 13mm | m | 4.20 | A045
| | thick) regrading to invert channel of 225 | | |
| | to 300mm wide surface drains including | | |
| | hacking off existing channel/plastering. | | |
| | | | |
| A046 | Sawn cut sides and hack off existing | m | 3.70 | A046
| | screed of scupper/water channel and | | |
| | regrade to fall with minimum 20mm thick | | |
| | 1:3 cement and sand mortar including | | |
| | make good affected areas. | | |
| | | | |

PAGE 4 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | CONCRETE WORK (CONT'D) | | |
| | | | |
| | * Reinforced precast concrete paving slabs | | |
| | laid on sand bed and jointed in cement | | |
| | and sand mortar. | | |
| | (excavation & removal of existing slabs | | |
| | to be measured separately) | | |
| | *(A047 A048) | | |
| | | | | Bldg TC
| A047 | 50mm thick | m2 | 24.30 | A047
| | | | | Bldg TC
| A048 | 75mm thick | m2 | 35.90 | A048
| | | | | Bldg TC
| A049 | 300x300x50mm thick polyproplene | m | 14.10 | A049
| | fibre reinforced vibro-compacted porous | | |
| | concrete slab with cement and 9 or 14mm | | |
| | thick aggregate (1:4) mix for concealed | | |
| | drain. | | |
| | | | |
| A050 | Labour for take out existing loose or | m2 | 3.20 | A050
| | sunken precast concrete paving | | |
| | slabs and stack aside for re-use | | |
| | including cart away damaged slabs | | |
| | | | |
| A051 | Select from stack and re-use existing | m2 | 5.00 | A051
| | 50/75 thick concrete slab (including | | |
| | sand binding and jointing in 1:3 cement | | |
| | mortar) | | |
| | | | | Bldg TC
| A052 | 600x400x100 mm thick precast concrete | m2 | 49.90 | A052
| | BG slab including sand bed to receive | | |
| | slab and turfing. (excavation measured | | |
| | separately) | | |
| | | | |
| | BRICKWORK AND BLOCKWORK | | |
| | | | |
| | * Common brickwall laid in 1:3 cement | | |
| | mortar with 10mm joints raked 10mm deep | | |
| | flushed pointed as works proceeds | | |
| | *(A053 A054) | | |
| | | | | Bldg TC
| A053 | Half brick thick reinforced with | m2 | 17.85 | A053
| | galvanised expanded metal reinforced | | |
| | at every 3rd course | | |
| | | | | Bldg TC
| A054 | One brick thick | m2 | 34.65 | A054
| | | | | Bldg TC
| A055 | Extra over ordinary brickwork for | m2 | 12.10 | A055
| | forming exposed faces in red/overburnt | | |
| | facing bricks and pointed in approved | | |
| | cement mortar | | |
| | | | | Bldg TC

PAGE 5 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | BRICKWORK AND BLOCKWORK (CONT'D) | | |
| | | | |
| A056 | One brick thick wall coping/capping with | m | 10.90 | A056
| | bull nose facing bricks laid in cement | | |
| | and sand mortar (1:3) including | | |
| | pointing. | | |
| | | | | Bldg TC
| A057 | Half brick-wall in standard common | m2 | 13.65 | A057
| | bricks built honeycomb laid in cement and | | |
| | sand mortar (1:3) with raked out joints | | |
| | or flush pointed as work proceeds. | | |
| | | | |
| | * Hollow block wall in cement and sand | | |
| | mortar (1:3) joints including expanded | | |
| | galvanised steel reinforcement at | | |
| | alternate course *(A058 A059) | | |
| | | | | Bldg TC
| A058 | 100mm thick | m2 | 15.00 | A058
| | | | | Bldg TC
| A059 | 150mm thick | m2 | 22.30 | A059
| | | | | Bldg TC
| A060 | 190(L)x190(B)x95/80(THK)mm glass blocks | m2 | 180.80 | A060
| | laid in cement and sand mortar (1:3) | | |
| | and reinforced with expanded metal | | |
| | reinforcement including pointing of | | |
| | joints as specified | | |
| | | | | Bldg TC
| A061 | Approved damp proof course complying | m2 | 7.70 | A061
| | with BS 6398 Type B (felt fibre base | | |
| | type) well lapped at joints and bedded | | |
| | in cement mortar (1:3) | | |
| | | | |
| A062 | Breaking up block/brickwall including | m3 | 49.60 | A062
| | finishes and cart away. | | |
| | | | |
| A063 | Labour and material pointing joints of | m2 | 3.50 | A063
| | brickworks in coloured cement. | | |
| | | | |
| A064 | Labour raking out joints of existing | m2 | 4.60 | A064
| | brickwork, clean, re-point with cement | | |
| | grout with a flush joint. | | |
| | | | |
| A065 | Cutting out existing block or brickwork | m | 40.90 | A065
| | to form chase etc including making | | |
| | good and removing debris off site. | | |
| | Not exceeding 300mm girth. | | |
| | | | |
| A066 | Cutting out existing block or brickwork | m | 46.30 | A066
| | to form chase etc exceeding 300mm | | |
| | and not exceeding 600mm girth | | |
| | including making good and | | |
| | removing debris off site. | | |
| | | | |

PAGE 6 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | BRICKWORK AND BLOCKWORK (CONT'D) | | |
| | | | |
| A067 | Hammer dressed random rubble in granite | m2 | 23.70 | A067
| | laid in cement mortar (1:3) as wall | | |
| | including pointing. | | |
| | | | |
| | FLOOR FINISHES | | |
| | | | |
| A068 | Heavy duty unglazed ceramic floor tiles | m2 | 37.30 | A068
| | (minimum 8mm thick) complying to | | |
| | BS 301:1984 and bedding on 20mm cement | | |
| | and sand to floor, kerbs, arises etc | | |
| | | | |
| A069 | Heavy duty unglazed ceramic nosing tiles | m | 7.50 | A069
| | in edging or steps laid and jointed on | | |
| | 20mm cement & sand screed | | |
| | | | | Bldg TC
| A070 | 300 x 300 x 9mm thk homogenous tiles for | m2 | 49.00 | A070
| | floor complying to SS 301 and bedding on | | |
| | 20mm thick cement and sand screed to | | |
| | floor, kerbs, risers etc | | |
| | | | | Bldg TC
| A071 | 10.5 mm thick approved homogeneous | m2 | 49.00 | A071
| | wall/floor tiles laid with prepack screed | | |
| | and bedded on 20mm thick 1:3 cement and | | |
| | sand mortar rendering (include kerbs and | | |
| | risers). | | |
| | | | |
| A072 | Mosaic to floor/wall to match existing | m2 | 45.20 | A072
| | including 1:3 cement and sand screed | | |
| | | | |
| A073 | Hack off concrete floor surfaces/ | m2 | 5.30 | A073
| | finishings to a depth not exceeding 50mm | | |
| | thick, form keys, clean and wash to | | |
| | receive new finishes including cart away | | |
| | debris to dumping ground | | |
| | | | |
| A074 | Hack existing floor to form keys, clean | m2 | 1.10 | A074
| | and wash to receive new finishes. | | |
| | | | |
| A075 | Apply one coat of approved bonding agent | m2 | 0.70 | A075
| | to concrete surface to receive new | | |
| | rendering/finishings. | | |
| | | | |
| A076 | Apply 2 coats "Quicseal 104"/ | m2 | 15.40 | A076
| | "Neogard-Perma III Elastomeric" or | | |
| | approved equivalent flexible cementitious | | |
| | liquid waterproofing membrane. | | |
| | | | |
| A077 | 20mm thick cement and sand (1:3) | m2 | 6.70 | A077
| | rendering to floor trowelled to a smooth | | |
| | finish including forming of expansion | | |
| | joints. | | |
| | | | |

PAGE 7 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | FLOOR FINISHES (CONT'D) | | |
| | | | |
| A078 | Add to (or deduct from) item A077 | m2 | 0.80 | A078
| | for each additional 5mm thick over (or | | |
| | under) 20mm cement and sand (1:3) | | |
| | rendering | | |
| | | | |
| | * 20mm thick cement and sand (1:3) | | |
| | rendering to skirtings, treads, risers, | | |
| | curbs and returns etc and trowelled to a | | |
| | smooth finish including coved and | | |
| | rounded angles. *(A079 A080) | | |
| | | | |
| A079 | 0 - 150mm girth | m | 1.90 | A079
| | | | |
| A080 | 151 - 300mm girth | m | 2.90 | A080
| | | | | Bldg TC
| A081 | 1:3 cement and sand mortar to form kerbs | m3 | 501.90 | A081
| | including trowelling smooth, form coved | | |
| | and rounded angles to exposed surfaces | | |
| | (Formwork measured separately). | | |
| | | | |
| A082 | 25mm thick concrete screed (Grade 30) | m2 | 9.10 | A082
| | with 10mm maximum size aggregates to | | |
| | concrete floor surface finished with | | |
| | steel trowel. | | |
| | | | |
| A083 | Add to (or deduct from) Item A082 for | m2 | 1.30 | A083
| | each 5mm thickness over (or under) 25mm | | |
| | (GRADE 30). | | |
| | | | |
| A084 | Extra over item A077, A078, A082 & A083 | m2 | 1.10 | A084
| | for approved waterproofing compound | | |
| | incorporated in the screed for each 5mm | | |
| | thickness. | | |
| | | | |
| A085 | Extra over manual trowelling with two | m2 | 2.40 | A085
| | passes of "Helicopter" power trowel to | | |
| | surface of concrete | | |
| | | | | Bldg TC
| A086 | Brick-on-edge paving of red facing | m2 | 33.40 | A086
| | bricks laid on 50mm thick 1:3 cement and | | |
| | sand mortar screed, joints and pointing | | |
| | | | | Bldg TC
| A087 | 190mm wide brick-on-edge curb in M211 | m | 13.45 | A087
| | bullnose/splayed edge red facing bricks | | |
| | and pointed in cement and sand mortar | | |
| | (1:3) as specified. (Cement and sand | | |
| | screed measured separately). | | |
| | | | |
| A088 | Re-pointing joints of existing mosaic | m2 | 4.20 | A088
| | floor in white cement including cleaning | | |
| | floor on completion. | | |
| | | | |

PAGE 8 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | FLOOR FINISHES (CONT'D) | | |
| | | | |
| A089 | Saw cut and hack to pot-hole in panel | m2 | 64.00 | A089
| | and patch up with 1:3 cement and sand | | |
| | mortar not exceeding 0.05 m2 per panel. | | |
| | | | |
| A090 | 5mm thick natural quartz epoxy screed | m2 | 33.80 | A090
| | finished with 2 coats of approved epoxy | | |
| | colour coatings including scarifying of | | |
| | existing surfaces to receive the epoxy | | |
| | screed. | | |
| | | | | Bldg TC
| A091 | 5mm thick approved epoxy screed system | m2 | 41.05 | A091
| | to concrete floor including preparation | | |
| | of floor surfaces (Rate include | | |
| | provision of 5 years warranty). | | |
| | | | |
| A092 | 2 coats approved coloured epoxy coatings | m2 | 7.30 | A092
| | to existing epoxy floor including | | |
| | preparing and cleaning of surfaces to | | |
| | receive the coatings. | | |
| | | | | Bldg TC
| A093 | 3mm thick(average) acrylic polymer | m2 | 14.50 | A093
| | cementitious coating system to ramps and | | |
| | driveways in multi-storey carpark. | | |
| | Surface of coating shall be brushed | | |
| | finished. Work shall be as specified in | | |
| | specification. | | |
| | | | |
| | * Natural aggregate concrete surface | | |
| | hardener to floor with 5 years warranty | | |
| | *(A094 A096) | | |
| | | | | Bldg TC
| A094 | 5kg/m2 | m2 | 6.10 | A094
| | | | | Bldg TC
| A095 | 7kg/m2 | m2 | 7.25 | A095
| | | | | Bldg TC
| A096 | 9kg/m2 | m2 | 13.35 | A096
| | | | |
| | CARPENTRY AND JOINERY | | |
| | | | |
| A097 | Sawn Kapoh, Balau,Keruing or Chengai in | m3 | 1,127.20 | A097
| | wall plates rafters, purlins,joists, | | |
| | collars, battens etc including | | |
| | tantalising or two coats of wood | | |
| | preservative. | | |
| | | | |
| | * Wrot Kapoh, Balau or Chengai | | |
| | *(A098 A099) | | |
| | | | |
| A098 | Fascia or barge boards. | m3 | 2,907.80 | A098
| | | | |

PAGE 9 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | CARPENTRY AND JOINERY (CONT'D) | | |
| | | | |
| A099 | Frame, head, mullion, transom or cill | m3 | 2,714.60 | A099
| | worked to the required shape. | | |
| | (the backs of door/window frames | | |
| | in contact with masonry work shall be | | |
| | painted with one coat wood preservative) | | |
| | | | |
| | * Moulded architrave, cover fillets, | | |
| | etc. *(A100 A101) | | |
| | | | |
| A100 | Not exceeding 500 sq mm in sectional | m | 1.40 | A100
| | area. | | |
| | | | |
| A101 | Exceeding 500 sq mm and not exceeding | m | 2.10 | A101
| | 1000 sq mm sectional area. | | |
| | | | |
| | * Louver blades *(A102 A103) | | |
| | | | |
| A102 | Not exceeding 2,000 sq mm sectional | m | 2.70 | A102
| | area. | | |
| | | | |
| A103 | Exceeding 2,000 sq mm and not exceeding | m | 5.10 | A103
| | 4,000 sq mm in sectional area. | | |
| | | | |
| | * Timber door (Door frame, ironmongery, | | |
| | wood primer and painting measured | | |
| | separately) *(A104 A106) | | |
| | | | | Bldg TC
| A104 | 38mm thick framed, ledged, braced | m2 | 115.00 | A104
| | and batten door comprising of 100 x | | |
| | 38mm styles and top rail, 150 x 19mm | | |
| | bottom ledge, 100 x 19mm middle ledge | | |
| | and braces filled in with 19mm thk | | |
| | tongued and grooved 'V' jointed boarding. | | |
| | | | | Bldg TC
| A105 | 50mm thick framed, ledged, braced | m2 | 170.10 | A105
| | and batten door comprising of 100 x | | |
| | 50mm styles and top rail, 150 x 25mm | | |
| | bottom ledge, 100 x 25mm middle ledge | | |
| | and braces filled in with 25mm thk | | |
| | tongued and grooved 'V' jointed boarding. | | |
| | | | | Bldg TC
| A106 | 45mm thk solid cored timber door | m2 | 158.70 | A106
| | comprising of 33mm thk tongued and | | |
| | grooved jointed boards fixed together | | |
| | with 3 nos 10mm dia. bolts and filled | | |
| | both faces with 6mm thk plywood lining | | |
| | and 19mm thk hardwood edging all round. | | |
| | | | |

PAGE 10 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | CARPENTRY AND JOINERY (CONT'D) | | |
| | | | |
| | * Louvered Door with framings stop | | |
| | and fill in with 13mm thick timber | | |
| | louvers including fixing fillets. | | |
| | *(A107 A108) | | |
| | | | | Bldg TC
| A107 | 38mm thick. | m2 | 149.50 | A107
| | | | | Bldg TC
| A108 | 45mm thick. | m2 | 178.40 | A108
| | | | |
| | * Skeleton framed flush door complying | | |
| | to BS 459 c/o hard wood edging all round | | |
| | and filled in both faces with 6mm thick | | |
| | plywood. *(A109 A110) | | |
| | | | | Bldg TC
| A109 | 38mm thick | m2 | 89.35 | A109
| | | | | Bldg TC
| A110 | 45mm thick | m2 | 105.95 | A110
| | | | | Bldg TC
| A111 | 38mm thick semi-solid cored flush door | m2 | 111.60 | A111
| | with fixed timber louvres on top | | |
| | comprising 100 x 38mm top rail and style, | | |
| | 150x38mm bottom rail, 75x25mm | | |
| | intermediate rail and muntin, 150 x 25mm | | |
| | lock rail, filled in on both sides with | | |
| | 6mm thick plywood lining and 16mm thk | | |
| | timber louvres slotted and fixed to | | |
| | style at 60 degrees angle and spaced not | | |
| | more than 30mm apart. | | |
| | | | | Bldg TC
| A112 | 38mm thick panel door in 4 panels | m2 | 104.60 | A112
| | filled in with 9.5mm thick plywood | | |
| | comprising of 100 x 38mm styles, | | |
| | intermediate and lock rails, 200 x 38mm | | |
| | top and bottom rails | | |
| | | | | Bldg TC
| A113 | 45mm thick panel door in 4 panels filled | m2 | 163.60 | A113
| | in with 9.5mm thick plywood comprising of | | |
| | 100 x 45mm styles, intermediate and | | |
| | lock rails, 200 x 45mm top and bottom | | |
| | rails | | |
| | | | | Bldg TC
| A114 | 45mm thk half hour fire-rated timber door | m2 | 188.30 | A114
| | approved by Spring S'pore & FSB c/o | | |
| | of solid timber core with 1.2mm thick | | |
| | aluminium sheet lining on both sides. | | |
| | | | |

PAGE 11 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | CARPENTRY AND JOINERY (CONT'D) | | |
| | | | |
| | * 45mm thick fire-rated timber door approved | | |
| | by Spring S'pore & FSB (Door frame and | | |
| | ironmongeries measured separately) | | |
| | *(A115 A116) | | |
| | | | | Bldg TC
| A115 | 1/2 hour single/double leaf | m2 | 153.95 | A115
| | | | | Bldg TC
| A116 | 1 hour single/double leaf | m2 | 248.55 | A116
| | | | | Bldg TC
| A117 | Extra over timber door for 100(w)x600(H)mm | no | 12.60 | A117
| | view panel comprising of 6mm thk georgian | | |
| | wired glass panel and 23 x 12mm timber | | |
| | beads on both sides. | | |
| | | | |
| | * 2 leave fire-rated composite timber door | | |
| | with wood ply finished approved by Spring | | |
| | S'pore & FSB c/o 2 Nos 150x300mm glass | | |
| | observation panels (Door frame and | | |
| | ironmongeries measured separately) | | |
| | *(A118 A119) | | |
| | | | | Bldg TC
| A118 | 1 hour fire-rated | m2 | 252.00 | A118
| | | | | Bldg TC
| A119 | 1/2 hour fire rated | m2 | 180.10 | A119
| | | | |
| | * Approved weather proofed (WBP) | | |
| | plywood in panels *(A120 A121) | | |
| | | | |
| A120 | 6mm thick. | m2 | 5.50 | A120
| | | | |
| A121 | 12mm thick. | m2 | 8.40 | A121
| | | | |
| A122 | Labour & materials filling up door lock | Door | 4.30 | A122
| | holes hinge rebates, etc including | | |
| | timber adhesive,sand-papering and | | |
| | knotting repaired surface (Painting | | |
| | measured separately) | | |
| | | | |
| A123 | Repair to warped timber door by taking | leaf | 11.70 | A123
| | down, dismantle, realign, re-tightening | | |
| | with additional screws and refixing. | | |
| | | | |
| A124 | Take down rotten/damaged timber frame, | m | 21.10 | A124
| | mullion and cills to doors/windows/vents | | |
| | including cutting, jointing and made good | | |
| | affected areas to match existing including | | |
| | a coat primer, one undercoat & 1 finishing | | |
| | coat enamel paint. | | |
| | | | |

PAGE 12 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | CARPENTRY AND JOINERY (CONT'D) | | |
| | | | |
| A125 | Take down decayed timber door/window, | m2 | 15.20 | A125
| | renew decayed part of members, refix to | | |
| | position including all necessary dowels | | |
| | and wedges (painting measured separately). | | |
| | | | | Bldg TC
| A126 | Repair to glass door (swing type) by | job | 108.70 | A126
| | replacing the top pivot and bottom insert | | |
| | including uplifting and re-alignment of | | |
| | door (per leaf) | | |
| | | | |
| A127 | To open locked door to gain access into | no | 4.80 | A127
| | premises where keys have been lost. | | |
| | | | |
| | IRONMONGERY | | |
| | | | |
| | * Mild Steel flat shoot bolts. *(A128 A129) | | |
| | | | | Bldg TC
| A128 | 100mm. | no | 3.05 | A128
| | | | | Bldg TC
| A129 | 200mm. | no | 3.60 | A129
| | | | |
| | * Brass barrel bolts *(A130 A131) | | |
| | | | | Bldg TC
| A130 | 150mm. | no | 6.20 | A130
| | | | | Bldg TC
| A131 | 250mm. | no | 7.25 | A131
| | | | |
| | * Stainless steel shoot bolts. *(A132 A133) | | |
| | | | | Bldg SOR
| A132 | 90 x 27mm barrel/square shoot bolt. | no | 5.00 | S/N 417
| | | | |
| A133 | 240 x 27mm barrel/square shoot bolt. | no | 6.30 | S/N 418
| | | | | Bldg TC
| A134 | 'Tiki' 200x19mm or 300x19mm stainless | no | 24.90 | A134
| | steel box type L/A flushbolt including dust | | |
| | proof socket. | | |
| | | | | Bldg TC
| A135 | Mild steel pad shoot bolt with "Pad lock" | no | 3.80 | A135
| | locking device. | | |
| | | | |
| | * Purpose made mild steel locking bar | | |
| | with 16mm diameter locking rod welded | | |
| | to flat handle with slot including all | | |
| | necessary hooks and shoots: | | |
| | *(A136 A139) | | |
| | | | | Bldg Tc
| A136 | 250mm long welded to 38 x 100 x 5mm | no | 7.25 | A136
| | thick flat handle. | | |
| | | | | Bldg TC
| A137 | 300mm long welded to 38mm x 100mm | no | 9.15 | A137
| | x 5mm thick flat handle. | | |
| | | | | Bldg TC

PAGE 13 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | IRONMONGERY (CONT'D) | | |
| | | | |
| A138 | 360mm long welded to 75 x 100 x 5mm | no | 10.90 | A138
| | thick flat handle. | | |
| | | | | Bldg TC
| A139 | 460mm long welded to 75mm x 100mm | no | 12.70 | A139
| | x 5mm thick flat handle. | | |
| | | | |
| | * 4mm thick stainless steel locking eyes: | | |
| | complete set *(A140 A141) | | |
| | | | | Bldg SOR
| A140 | Single leaf door. | set | 15.40 | S/N 429
| | | | | Bldg SOR
| A141 | Double leaf door. | set | 22.30 | S/N 430
| | | | |
| | * Butt hinges *(A142 A148) | | |
| | | | | Bldg SOR
| A142 | 100 x 70 x 1.8 mm thick stainless steel. | no | 3.90 | S/N 423
| | | | | Bldg SOR
| A143 | 102 x 76 x 2mm thick stainless steel | no | 4.40 | S/N 424
| | | | | Bldg Tc
| A144 | 102 x 76 x 2.5mm thick stainless steel. | no | 4.30 | A144
| | | | | Bldg Tc
| A145 | 127 x 89 x 3mm thick stainless steel 2BB | no | 6.60 | A145
| | | | | Bldg Tc
| A146 | 75mm pressed steel. | no | 2.65 | A146
| | | | | Bldg Tc
| A147 | 100mm pressed steel. | no | 2.95 | A147
| | | | | Bldg Tc
| A148 | 150mm pressed steel. | no | 5.05 | A148
| | | | | Bldg Tc
| A149 | 100mm(H) x12mm diameter custom made | no | 7.90 | A149
| | mild steel bolt hinge to mild steel folding | | |
| | door. | | |
| | | | | Bldg Tc
| A150 | 600mm mild steel heavy duty hook and | no | 21.95 | A150
| | band hinges. | | |
| | | | | Bldg Tc
| A151 | Brass casement stays to metal casement | no | 5.80 | A151
| | windows. | | |
| | | | | Bldg Tc
| A152 | Chromium plated casement fastener | no | 11.70 | A152
| | complete with handle, nut, washer etc. to | | |
| | metal casement window. | | |
| | | | | Bldg Tc
| A153 | 100mm anodised aluminium 'U' shaped | no | 2.20 | A153
| | door handle. | | |
| | | | |
| | * Black Japanned bow handle. | | |
| | *(A154 A155) | | |
| | | | | Bldg Tc
| A154 | 100mm | no | 2.20 | A154
| | | | | Bldg Tc
| A155 | 150mm | no | 2.40 | A155

PAGE 14 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | IRONMONGERY (CONT'D) | | |
| | | | |
| | * Black Japanned cabin hook and | | |
| | eyes. *(A156 A157) | | |
| | | | | Bldg Tc
| A156 | 100mm. | no | 1.80 | A156
| | | | | Bldg Tc
| A157 | 150mm. | no | 2.00 | A157
| | | | |
| | * Hasp and staple *(A158 A162) | | |
| | | | | Bldg Tc
| A158 | 100mm Black Japanned. | no | 2.30 | A158
| | | | | Bldg Tc
| A159 | 150mm Black Japanned. | no | 3.40 | A159
| | | | | Bldg Tc
| A160 | 220x75x6mm thk heavy | no | 29.20 | A160
| | duty brass | | |
| | | | | Bldg Tc
| A161 | Heavy duty type for roof top trap door. | no | 5.40 | A161
| | | | | Bldg Tc
| A162 | 600mm mild steel heavy duty type for | no | 23.40 | A162
| | bin compound door. | | |
| | | | | Bldg Tc
| A163 | Castor wheel to metal sliding gate. | no | 27.30 | A163
| | | | | Bldg Tc
| A164 | PVC bearing (roller guide)to metal | no | 47.80 | A164
| | sliding gate. | | |
| | | | | Bldg Tc
| A165 | 8mm thick rubber mat as impact | m2 | 95.55 | A165
| | buffer for mild steel sliding gate | | |
| | including fixing accessories | | |
| | | | | Bldg Tc
| A166 | 12mm thick rubber mat as impact | m2 | 171.50 | A166
| | buffer for mild steel sliding gate | | |
| | including fixing accessories | | |
| | | | |
| | * 5-pin double cylinder mortice | | |
| | lockset *(A167 A169) | | |
| | | | | Bldg Tc
| A167 | Union 675-41-278SS or other approved | no | 94.80 | A167
| | (with handle). | | |
| | | | | Bldg Tc
| A168 | Union 214-SC/2.5 or other approved | no | 70.70 | A168
| | (without handle). | | |
| | | | | Bldg Tc
| A169 | 'Accord 7588WO' double cylinder mortice | no | 37.60 | A169
| | lockset with keys complete. | | |
| | | | | Bldg Tc
| A170 | 'Accord 7588WO or 70mm Papiaz' double | no | 21.20 | A170
| | cylinder with keys to 'Accord 7588WO' | | |
| | mortice lockset. | | |
| | | | | Bldg Tc

PAGE 15 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | IRONMONGERY (CONT'D) | | |
| | | | |
| A171 | Roller shutter lockset ("Viro 8202/8203" | no | 50.20 | A171
| | or other approved). | | |
| | | | |
| A172 | 'Accord' 608s mortice lockcase complete | no | 157.50 | Z002
| | with stainless steel lever handle and | | |
| | 200 x 200mm plate. | | |
| | | | | Bldg Tc
| A173 | Union 1028 WE or other approved cylinder | no | 58.60 | A173
| | rim night latch (with handle). | | |
| | | | | Bldg Tc
| A174 | Rim drawback lock with deadbolt of | no | 58.60 | A174
| | Union 1332 or other approved (with handle). | | |
| | | | | Bldg Tc
| A175 | Union 2177 or other approved mortice | no | 28.50 | A175
| | dead lock complete with handle. | | |
| | | | | Bldg Tc
| A176 | Union 2295 or other approved mortice | no | 21.20 | A176
| | sash lock complete with handle. | | |
| | | | | Bldg Tc
| A177 | Union 2277 or other approved mortice | no | 28.50 | A177
| | sash lock complete with handle. | | |
| | | | | Bldg Tc
| A178 | Extra over item A174, A175, A176, A177 | no | 6.70 | A178
| | for rebate component. | | |
| | | | | Bldg Tc
| A179 | Union 9301-SS or other approved knobset | no | 15.10 | A179
| | with emergency release for bathroom/toilet | | |
| | door. | | |
| | | | | Bldg Tc
| A180 | Double cylinder deadbolt (without key | no | 12.40 | A180
| | alike ) to handicap toilet door | | |
| | | | | Bldg Tc
| A181 | Double cylinder deadbolt (with key alike) | no | 19.65 | A181
| | to handicap toilet door | | |
| | | | | Bldg Tc
| A182 | Stainless steel indicating bolt (without | no | 11.55 | A182
| | coin opening). | | |
| | | | | Bldg Tc
| A183 | Mortice dead lock. | no | 18.80 | A183
| | (Yale M902) or other approved equivalent | | |
| | | | | Bldg Tc
| A184 | Rim latch with locking snib. | no | 28.45 | A184
| | (Union 1209 or other approved) | | |
| | | | | Bldg Tc
| A185 | Cylinder rim night latch. | no | 59.85 | A185
| | (Union 1022 or other approved) | | |
| | | | | Bldg Tc
| A186 | 'Yale 3202A/214.62' mortise night latch | no | 43.05 | A186
| | in MKAA system including keys. | | |
| | | | | Bldg Tc
| A187 | Latchset "Union 2642/SC/4W/rp003.BB" | no | 36.90 | A187
| | complete with fixing accessories | | |

PAGE 16 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | IRONMONGERY (CONT'D) | | |
| | | | | Bldg Tc
| A188 | Double cylinder lockset '138 Yale MD | no | 78.55 | A188
| | 32828' door lockset (exclude rebate). | | |
| | | | |
| A189 | "Yale CRR8747FL US32D" entrance lock | no | N.A |
| | complete. | | |
| | | | | Bldg Tc
| A190 | "Yale CRR8747FL US32D" entrance lock | no | 75.30 | A190
| | with keys. | | |
| | | | | Bldg Tc
| A191 | 'Yale 214.62' single cylinder thumturn | no | 39.05 | A191
| | cylinder (complete with keys) | | |
| | | | | Bldg Tc
| A192 | 'Accord 1405-SN' single cylinder thumb- | no | 44.10 | A192
| | turn mortice including keys. | | |
| | | | | Bldg Tc
| A193 | 'Accord 2332/1405' single cylinder | no | 30.35 | A193
| | thumbturn mortice ('Key-alike') stainless | | |
| | steel night latch. | | |
| | | | | Bldg Tc
| A194 | "Accord CH-382" stainless steel | no | 33.80 | A194
| | cup handle passage latch with cup | | |
| | handle on both sides. | | |
| | | | | Bldg Tc
| A195 | Extra over "Accord CH-382" stainless | no | 7.90 | A195
| | steel cup handle passage latch for | | |
| | brass rebate. | | |
| | | | | Bldg Tc
| A196 | 'Union 2241' key cylinder with keys | no | 25.50 | A196
| | | | |
| A197 | Aluminium finish mortice lever lockset to | no | 21.60 | A197
| | metal grille gate. (Yale L315A/M246/2 | | |
| | 1/2" or other approved) | | |
| | | | | Bldg Tc
| A198 | "Tri-circle 265" 50mm padlock. | no | 7.25 | A198
| | | | | Bldg Tc
| A199 | Crescent lock with key to aluminium | no | 19.95 | A199
| | sliding window. | | |
| | | | | Bldg Tc
| A200 | Brass cupboard/drawer lock of approved type | no | 4.00 | A200
| | | | | Bldg Tc
| A201 | Indicating bolt for toilet door. | no | 26.25 | A201
| | (Union 8098 or other approved). | | |
| | | | | Bldg Tc
| A202 | Cam lock for letter box (Abloy 2373, | no | 13.55 | A202
| | Yale 490 or other approved). | | |
| | | | | Bldg Tc
| A203 | Letter box lockset for postman. | no | 54.40 | A203
| | | | | Bldg Tc
| A204 | 'C-S1' or other approved spring lock | no | 18.90 | A204
| | to dry riser breeching inlet cabinet. | | |
| | | | | Bldg Tc

PAGE 17 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | IRONMONGERY (CONT'D) | | |
| | | | |
| A205 | 38mm diameter 25mm thick rubber door | no | 2.65 | A205
| | stop. | | |
| | | | | Bldg Tc
| A206 | 'YTL-800' slimline door closer with | no | 36.65 | A206
| | cushioned back checking action | | |
| | | | | Bldg Tc
| A207 | 'YTL-60' brass ball catch. | no | 4.00 | A207
| | | | | Bldg Tc
| A208 | 'YTL-DS002S' stainless steel spring | no | 9.80 | A208
| | loaded dust proof socket. | | |
| | | | | Bldg Tc
| A209 | Door closer "Dorma TS 7301" size 3 hold | no | 131.05 | A209
| | open arms. | | |
| | | | | Bldg Tc
| A210 | Door closer 'Dorma 8815' stainless | no | 63.40 | A210
| | steel level handle. | | |
| | | | | Bldg Tc
| A211 | Duplicate key to match existing. | no | 2.40 | A211
| | | | | Bldg Tc
| A212 | Duplicate sub-master key for 'Yale | no | 6.10 | A212
| | MK48' using original 'Yale' blank key. | | |
| | | | | Bldg Tc
| A213 | 300mm long chain with bracket and ring | no | 5.15 | A213
| | to metal box/door etc. for padlock. | | |
| | | | |
| | * Accessories to steel sliding and | | |
| | folding doors of workshops. *(A214 A236) | | |
| | | | | Bldg Tc
| A214 | "Abloy 4960" complete with keys or | no | 159.60 | A214
| | equal and approved. | | |
| | | | |
| A215 | "Henderson 67/89" intermediate roller | no | 29.20 | A215
| | guide. | | |
| | | | |
| A216 | "Henderson 67/97" intermediate roller | no | 29.20 | A216
| | guide. | | |
| | | | |
| A217 | "Henderson 67C/97" intermediate roller | no | 83.90 | A217
| | guide. | | |
| | | | |
| A218 | "Henderson 68/89" end roller guide. | no | 20.70 | A218
| | | | |
| A219 | "Henderson 68/97" end roller guide. | no | 21.60 | A219
| | | | |
| A220 | "Henderson 68C/97" end roller guide. | no | 50.30 | A220
| | | | |
| A221 | "Henderson 62K" intermediate hanger. | no | 46.80 | A221
| | | | |
| A222 | "Henderson 62A" intermediate hanger. | no | 56.70 | A222
| | | | |
| A223 | "Henderson 62C" intermediate hanger. | no | 162.70 | A223
| | | | |

PAGE 18 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | IRONMONGERY (CONT'D) | | |
| | | | |
| A224 | "Henderson 63K" end hanger. | no | 38.10 | A224
| | | | |
| A225 | "Henderson 63A" end hanger. | no | 52.00 | A225
| | | | |
| A226 | "Henderson 63C" end hanger. | no | 92.80 | A226
| | | | |
| A227 | "Henderson 97" steel channel. | m | 25.00 | A227
| | | | |
| A228 | "Henderson 1A/290" heavy duty alloy | no | 11.00 | A228
| | bracket including all necessary bolt | | |
| | drilling and painting. | | |
| | | | |
| A229 | "Henderson 1A/301" heavy duty alloy | no | 17.70 | A229
| | bracket including all necessary bolt | | |
| | drilling and painting. | | |
| | | | |
| A230 | "Henderson 1A/305" heavy duty alloy | no | 36.10 | A230
| | bracket including all necessary bolt | | |
| | drilling and painting. | | |
| | | | |
| A231 | "Henderson 290" galvanised track. | m | 18.90 | A231
| | | | |
| A232 | "Henderson 301" galvanised track. | m | 27.60 | A232
| | | | |
| A233 | "Henderson 305" galvanised track. | m | 55.30 | A233
| | | | |
| A234 | "Henderson 994R" 380mm galvanised steel | no | 38.40 | A234
| | shoot with brass roller | | |
| | | | |
| A235 | "Henderson 65" back flap hinges. | no | 20.70 | A235
| | | | |
| A236 | "Henderson 65C" back flap hinges. | no | 81.20 | A236
| | | | |
| | STRUCTURAL STEELWORK & METALWORK | | |
| | | | |
| | * Lift Certificate holder *(A237 A238) | | |
| | | | | Bldg Tc
| A237 | 170mm x 220mm x 5mm clear perspex sheet | no | 7.25 | A237
| | with polished edges and 4 Nos stainless | | |
| | steel 'philip' head self tapering screw. | | |
| | | | | Bldg Tc
| A238 | 170mm x 220mm x 5mm clear perspex | no | 23.00 | A238
| | sheet with 13 x 5 x 13mm aluminium 'U' | | |
| | channel framing fix to lift car by | | |
| | pop-riveting. | | |
| | | | | Bldg Tc
| A239 | Brass roller to roof top access trap | no | 15.25 | A239
| | door. | | |
| | | | | Bldg Tc
| A240 | Metal rails to roof top access trap | m | 16.60 | A240
| | door. | | |
| | | | | Bldg Tc

PAGE 19 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | STRUCTURAL STEELWORK & METALWORK | | |
| | (CONT'D) | | |
| | | | |
| A241 | 1mm thick aluminium sheet as cover, | m2 | 21.95 | A241
| | linings and flashing to roof trap door | | |
| | including bending and fixing accessories. | | |
| | | | | Bldg Tc
| A242 | 5mm thick stainless steel eye anchor of | no | 2.65 | A242
| | internal diameter 15mm of Grade A1S1 304 | | |
| | including epoxy putty and nylon plug. | | |
| | | | | Bldg Tc
| A243 | Flag Pole holder hot dipped galvanised | no | 34.25 | A243
| | comprising of 40mm diameter pipe welded | | |
| | to 5mm thick plate to detail bolted to | | |
| | concrete surface with 10 x 90mm 'Hilti | | |
| | HSAR' or approved anchor bolt. | | |
| | | | | Bldg Tc
| A244 | Flag Pole holder hot dipped galvanised | no | 33.80 | A244
| | comprising of 31 x 31 x 2.3 mm thick | | |
| | square hollow section to detail bolted | | |
| | to concrete surface with 10 x 90 mm | | |
| | 'Hilti Hsar' or approved anchor bolt. | | |
| | | | | Bldg SOR
| A245 | Mild steel Grade 43A to BS 4360 | kg | 3.80 | S/N 498
| | for flats, angles, tees,channels, | | |
| | hollow sections, square sections, | | |
| | rivets and bolts, etc. of any size | | |
| | fabricated and fixed including | | |
| | welding or bolting, and painting | | |
| | with one coat of lead and | | |
| | chromate-free primer | | |
| | (structural steel work only) | | |
| | | | | Bldg SOR
| A246 | Mild steel flats, angles, tees, | kg | 3.30 | S/N 499
| | channels, rviets and bolts, etc. | | |
| | of any size fabricated and fixed | | |
| | including welding or bolting (for | | |
| | non-structural steel wokrk only) | | |
| | | | | Bldg SOR
| A247 | Extra over mild steel rods, flats, | kg | 0.60 | S/N 500
| | angles, tees, channel, hollow sections, | | |
| | rivets, bolts, etc for galvanising | | |
| | in lieu of painting on coat of lead | | |
| | and chromate-free primer. | | |
| | | | |
| A248 | Extra over mild steel rods, flats, | kg | 0.80 | Bldg SOR
| | angles, tees, channels, hollow | | | S/N 501
| | sections, rivets, botls, etc. | | |
| | for galvanising | | |
| | | | |

PAGE 20 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | STRUCTURAL STEELWORK & METALWORK | | |
| | (CONT'D) | | |
| | | | |
| A249 | 100mm diameter x 6mm thick mild steel | no | 72.90 | Z003
| | hollow section bollards with | | |
| | complete with 6mm thick end cap and | | |
| | 200 x 200 x 6mm thick base plate with stiffener | | |
| | including all necessary welding and painting | | |
| | with 1 primer coat and two | | |
| | coats of enamel paint. | | |
| | | | |
| A250 | Spot welding loose / corroded metal | no | 0.70 | A250
| | work | | | Jan 06'
| | | | | CE SOR
| A251 | 3mm thick hot-dipped galvanised mild | m2 | 65.90 | S/N 6.11
| | steel chequered plate cut to size and | | |
| | welded to mild steel works. | | |
| | | | | Bldg Tc
| A252 | Welded steel fabric RN 228 to vent | m2 | 9.15 | A252
| | including all necessary cutting and | | |
| | welding (painting measured separately). | | |
| | | | | Bldg Tc
| A253 | Galvanised mesh no. 5518 fixed to | m2 | 7.60 | A253
| | openings (excluding frame). | | |
| | | | | Bldg Tc
| A254 | 2mm thick perforated aluminium sheet | m2 | 95.55 | A254
| | | | | Bldg Tc
| A255 | 2mm thick aluminium sheet fixed to | m2 | 40.10 | A255
| | frame including fixing accessories(Frame | | |
| | and painting measured separately). | | |
| | | | |
| | * Mild steel vertical trap grating to 250 | | |
| | /300mm wide surface water channel of the | | |
| | following depth comprising 10mm | | |
| | diameter vertical bars spaced 38mm | | |
| | centre, all framed up and welded to 25mm | | |
| | x 25mm x 5mm thick angle horizontal top | | |
| | piece and 25mm x 5mm thick flat | | |
| | intermediate piece, the ends of horizontal | | |
| | top piece split and fixed to sides of | | |
| | channel including 1 priming coat and 2 | | |
| | coats of enamel paint.*(A256 A257) | | |
| | | | | Bldg Tc
| A256 | Not exceeding 450mm deep | no | 19.00 | A256
| | | | | Bldg Tc
| A257 | Exceeding 450mm but not exceeding | no | 20.05 | A257
| | 750mm deep. | | |
| | | | | Bldg Tc
| A258 | Labour and materials for refixing | no | 6.20 | A258
| | fallen bicycle stands | | |
| | | | | Bldg Tc

PAGE 21 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | STRUCTURAL STEELWORK & METALWORK | | |
| | (CONT'D) | | |
| | | | |
| A259 | Standard bicycle parking rack | no | 22.25 | A259
| | comprising of 0.63m x 65mm diameter mild | | |
| | steel pipe welded at top diameter mild | | |
| | steel pipe welded at top 480mm above | | |
| | ground level, the other end embedded | | |
| | 150mm deep in concrete (1:2:4) with 2 | | |
| | nos of 0.84m x 13mm diameter mild steel | | |
| | bar bent and welded for single side | | |
| | parking including 3 coats of oil paint | | |
| | and making good etc. | | |
| | | | | Bldg Tc
| A260 | Standard bicycle parking rack | no | 28.60 | A260
| | comprising of 1.68m x 13mm diameter mild | | |
| | steel bar for double sides parking. | | |
| | | | |
| | * 'Hilti-HAS' or other approved adhesive | | |
| | anchor including drilling holes and | | |
| | all necessary preparation according to | | |
| | manufacturer's instruction ( Chemical | | |
| | capsule measured separately). | | |
| | *(A261 A264) | | |
| | | | | Bldg Tc
| A261 | 8mm diameter x 80mm length anchor | no | 2.75 | A261
| | | | | Bldg Tc
| A262 | 10mm diameter x 90mm length anchor | no | 3.25 | A262
| | | | | Bldg Tc
| A263 | 12mm diameter x 110mm length anchor | no | 4.20 | A263
| | | | | Bldg Tc
| A264 | 16mm diameter x 126mm length anchor | no | 6.30 | A264
| | | | |
| | * Chemical Capsule 'Hilti' or other | | |
| | approved equivalent to manufacturer's | | |
| | instruction. *(A265 A268) | | |
| | | | | Bldg Tc
| A265 | Hilti HVU M8 | no | 4.75 | A265
| | | | | Bldg Tc
| A266 | Hilti HVU M10 | no | 5.80 | A266
| | | | | Bldg Tc
| A267 | Hilti HVU M12 | no | 6.50 | A267
| | | | | Bldg Tc
| A268 | Hilti HVU M16 | no | 8.60 | A268
| | | | |
| | * Galvanised medium duty expansion | | |
| | anchor bolt 'Hilti HAS-KA' or other | | |
| | approved equivalent including stud | | |
| | anchor, nut and washer *(A269 A274) | | |
| | | | | Bldg Tc
| A269 | 6mm diameter x 65mm length | no | 1.70 | A269
| | | | | Bldg Tc
| A270 | 8mm diameter x 75mm length | no | 2.95 | A270
| | | | |

PAGE 22 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | STRUCTURAL STEELWORK & METALWORK | | | Bldg Tc
| | (CONT'D) | | |
| | | | |
| A271 | 10mm diameter x 90mm length | no | 3.50 | A271
| | | | | Bldg Tc
| A272 | 12mm diameter x 110mm length | no | 4.40 | A272
| | | | | Bldg Tc
| A273 | 16mm diameter x 145mm length | no | 9.70 | A273
| | | | | Bldg Tc
| A274 | 20mm diameter x 170mm length | no | 10.50 | A274
| | | | | Bldg Tc
| A275 | 20mm diameter galvanised heavy duty | no | 39.40 | A275
| | expansion anchor bolt 'Hilti HSL' or | | |
| | other approved equivalent including stud | | |
| | anchor, nut and washer. | | |
| | | | | Bldg Tc
| A276 | Ramset nail including the use of gun | no | 0.40 | A276
| | and explosives. | | |
| | | | | Bldg Tc
| A277 | Ramset threaded stud including the use | no | 0.75 | A277
| | of gun and explosive. | | |
| | | | | Bldg Tc
| A278 | 25 x 3 x 230mm long steel holdfast. | no | 1.70 | A278
| | | | | Bldg Tc
| A279 | Cut into existing wall and incorporate | no | 4.30 | A279
| | new 25 x 3 x 230mm long steel holdfast | | |
| | including filling up hole with 1:3 | | |
| | cement mortar and painting/tiling to | | |
| | match. | | |
| | | | | Bldg Tc
| A280 | Pop Rivet to aluminium louvre blades or | no | 0.20 | A280
| | other aluminium fittings. | | |
| | | | |
| A281 | Gauge 18 standard approved aluminium | no | 92.60 | A281
| | w.c. or bathroom doors 800mm wide x | | |
| | 1800mm height, including hook and band | | |
| | hinges and cabin hook. | | |
| | | | |
| A282 | To re-fasten loose hinges of aluminium door | leaf | 2.80 | A282
| | including screw and rivet if necessary. | | |
| | | | |
| A283 | PVC w.c or bathroom door of approved | m2 | 96.10 | A283
| | type door including 3 Nos stainless | | |
| | steel hinges (lock measured separately). | | |
| | | | | Bldg Tc
| A284 | Gauge 20 purpose-made galvanised sheet | m | 6.95 | A284
| | expansion joint cover 150mm wide the "V" | | |
| | shaped groove in centre including fixing | | |
| | with masonary nails and washers at 150mm | | |
| | centres at both edge. | | |
| | | | |

PAGE 23 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | STRUCTURAL STEELWORK & METALWORK | | |
| | (CONT'D) | | |
| | | | |
| A285 | Take out loose galvanised steel | m | 5.00 | A285
| | expansion joint and repair to cracked/ | | |
| | chipped wall and refix with masonary nail | | |
| | with washer at 150mm centres at both | | |
| | edge. | | |
| | | | | Bldg Tc
| A286 | Natural anodised aluminium letter box, | set | 120.10 | A286
| | size 400 x 270 x 144mm / 380 x 270 x | | |
| | 150mm/380/270/110mm fabricated in | | |
| | accordance with HDB's standard drawings | | |
| | including locks and keys, engraving with | | |
| | unit numbers (masonry work measured | | |
| | separately). | | |
| | | | | Bldg Tc
| A287 | Anodised aluminium letter box flap | no | 12.90 | A287
| | complete with engraving of unit numbers | | |
| | to match existing. | | |
| | | | | Bldg Tc
| A288 | Two-way natural anodized aluminum | no | 178.20 | A288
| | letter box, o/a size 270 x 150 x 400mm, | | |
| | including master door, locks and keys | | |
| | and engraving with unit numbers, block | | |
| | numbers and street name | | |
| | | | |
| | * 1.2mm thick natural anodised aluminium | | |
| | roller shutter complete with all | | |
| | necessary components in accordance with | | |
| | manufacturer's instructions, fixing | | |
| | accessories and removal of existing if | | |
| | any. *(A289 A291) | | |
| | | | | Roller So
| A289 | Manual operated. | m2 | 140.00 | A100
| | | | | Bldg Tc
| A290 | Chain operated. | m2 | 160.00 | A290
| | | | | Roller So
| A291 | Motorised operated. | m2 | 167.60 | A101
| | | | | Bldg Tc
| A292 | 4 hours fire-rated electric operated | m2 | 332.35 | A292
| | roller shutter galvanise finished c/w | | |
| | ironmongeries and fixing accessories etc | | |
| | complete including commissioning(Spring | | |
| | S'pore & FSB approved fire-rated) | | |
| | | | | Bldg Tc
| A293 | Roller shutter bearing 100mm diameter x | no | 40.20 | A293
| | 20mm width including reset system to | | |
| | function. | | |
| | | | | Bldg Tc
| A294 | Replace chain block of roller shutter | no | 1,183.35 | A294
| | door including adjusting shutter's | | |
| | aligment, tightening of loosen parts and | | |
| | greasing. | | |
| | | | | Bldg Tc

PAGE 24 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | STRUCTURAL STEELWORK & METALWORK | | |
| | (CONT'D) | | |
| | | | |
| A295 | Supply labour, tools and stagging (if | set | 230.00 | A295
| | necessary) for dismantling and cart | | |
| | away existing roller shutter. | | |
| | | | | Bldg Tc
| A296 | Remove existing damaged roller shutter | m2 | 252.40 | A296
| | and replace with electrically operated | | |
| | 1 hour fire rated shutter curtain, | | |
| | complete with electric motor, powder | | |
| | coating according to FSB 476 P22, | | |
| | fusible link mechanism, side guide, | | |
| | hand chain, bottom bar, PSB approved | | |
| | fire door certificate and tested to | | |
| | SS489, 2001, including all | | |
| | other necessary accessories | | |
| | | | | Bldg Tc
| A297 | Roller shutter IC card including reset | no | 181.15 | A297
| | to function. | | | Yr05
| | | | | Roller So
| A298 | PVC weather seal to roller shutter | no | 50.00 | A058
| | | | | Bldg Tc
| A299 | 45mm thick mild steel sliding and | m2 | 137.90 | A299
| | folding door constructed of 1.6mm thick | | |
| | plate(preformed and bend to shape in | | |
| | factory) including timber packing piece, | | |
| | mild steel angles, locking eyes, floor | | |
| | channels and shoot bolts (All hanging | | |
| | track, guide and ironmongeries not | | |
| | specified shall be measured separately.) | | |
| | | | |
| | * Fire-rated steel door with approved | | |
| | steel frame, 125mm stainless steel butt | | |
| | hinges, door closer and mortise lock | | |
| | ('Spring' approved fire-rated with | | |
| | label) (Painting measured separately) | | |
| | *(A300 A301) | | |
| | | | | Bldg Tc
| A300 | 1 hour fire-rated | m2 | 492.15 | A300
| | | | | Bldg Tc
| A301 | 2 hours fire-rated | m2 | 492.15 | A301
| | | | | Bldg Tc
| A302 | 1/2 hour fire-rated heavy duty | m2 | 694.90 | A302
| | aluminium door c/o aluminium extruded | | |
| | section frame, ironmongeries and panic | | |
| | hardware from inside(PSB approved | | |
| | fire-rated) | | |
| | | | | Bldg Tc
| A303 | 4 hours fire-rated heavy duty aluminium | m2 | 977.70 | A303
| | door c/o aluminium extruded section | | |
| | frame, ironmongeries and panic hardware | | |
| | from inside (PSB approved fire-rated) | | |
| | | | | Bldg Tc

PAGE 25 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | STRUCTURAL STEELWORK & METALWORK | | |
| | (CONT'D) | | |
| | | | |
| A304 | 4 hours fire-rated heavy duty aluminium | m2 | 1,073.00 | A304
| | louvre door fitted with panic hardware | | |
| | from inside, ironmongeries, fixing | | |
| | accessories and door frame complete | | |
| | (PSB approved fire-rated) | | |
| | | | |
| A305 | Provide labour, tools and sundries to | m2 | 4.80 | A305
| | take down existing mild steel sliding | | |
| | and folding door to overhaul, cease, | | |
| | adjust and grease all parts. Repairs and | | |
| | replacement to corroded section of door | | |
| | including necessary welding and to | | |
| | reinstall to slide properly.(Replacement | | |
| | of ironmongery item measured separately) | | |
| | | | |
| A306 | Labour to weld back metal gate padlock | no | 2.70 | A306
| | eye. | | |
| | | | |
| A307 | Labour taking down mild steel gates/ | m2 | 4.80 | A307
| | metal grilles including removal of bolts | | |
| | and patch up holes | | |
| | | | |
| | * Aluminium adjustable lourved | | |
| | window frames comply with SS212 | | |
| | for louvres per set including | | |
| | rattleproof spring clips and all | | |
| | necessary bolts and nuts and fixed at | | |
| | wood, concrete or brick etc.(Measurement | | |
| | shall be height per light and louvres | | |
| | blades measured separately). *(A308 A310) | | |
| | | | |
| A308 | Natural anodised and single control. | m | 34.80 | A308
| | | | |
| A309 | Natural anodised and dual control. | m | 35.50 | A309
| | | | |
| A310 | Bronze anodised and single control | m | 38.60 | A310
| | | | |
| A311 | Extra over single/double control | m | 8.20 | A311
| | aluminium adjustable louvre window frame | | |
| | complying to SS 212 for burglar bar | | |
| | (Measurement shall be by height of | | |
| | window per light). | | |
| | | | |

PAGE 26 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | STRUCTURAL STEELWORK & METALWORK | | |
| | (CONT'D) | | |
| | | | |
| | * Galvanised steel adjustable louvred | | |
| | windows frames for 150mm wide glass or | | |
| | aluminium lacquered louvres per set | | |
| | including rattleproof spring clips and | | |
| | all necessary bolts and nuts and fixed | | |
| | at wood, concrete or brick etc. | | |
| | (Measurement shall be height per light | | |
| | and louvres blades measured separately). | | |
| | *(A312 A315) | | |
| | | | |
| A312 | Single control | m | 14.30 | A312
| | | | |
| A313 | Single control and burglar proof type. | m | 16.60 | A313
| | | | |
| A314 | Dual control. | m | 15.60 | A314
| | | | |
| A315 | Dual control and burglar proof type. | m | 17.00 | A315
| | | | | Bldg Tc
| A316 | 10mm square galvanised burglar proof | m | 3.60 | A316
| | bar to louvred window. | | |
| | | | |
| A317 | 1.6mm thick extruded aluminium louvred 5 | no | 6.50 | A317
| | blades size not exceeding 600mm x 150mm | | |
| | wide in anodised finish to fixed/ | | |
| | adjustable louvred window. | | |
| | | | |
| A318 | Fix re-used metal louvre blade to | no | 1.20 | A318
| | adjustable louvre window including | | |
| | removal of existing if any. | | |
| | | | | Bldg Tc
| A319 | Powder coated aluminium fixed | m2 | 265.45 | A319
| | louvred vent c/o 5mm thk tinted glass, | | |
| | alum framing, ironmongery and cill, | | |
| | cement mortar infill and all necessary | | |
| | fixing and jointing accessories. | | |
| | | | |
| A320 | Repair to adjustable louvre window | Light | 3.50 | A320
| | including the use of all necessary | | |
| | fitting parts, easing of window, | | |
| | dismantle and refixing all frames and | | |
| | louvres. (Regardless of height) | | |
| | | | |
| A321 | 1.2mm thk bronze anodised extruded | m2 | 286.10 | A321
| | aluminium framed casement window with | | |
| | sheet float glass, aluminium fronting, | | |
| | ironmongery and cill with cement mortar | | |
| | infill and all necessary fixing and | | |
| | jointing materials and accessories as | | |
| | specified with 5mm thick clear sheet | | |
| | float glass. | | |
| | | | |

PAGE 27 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | STRUCTURAL STEELWORK & METALWORK | | |
| | (CONT'D) | | |
| | | | |
| A322 | 1.2mm thk natural anodised extruded | m2 | 219.80 | A322
| | aluminium framed casement window with | | |
| | sheet float glass, aluminium fronting, | | |
| | ironmongery and cill with cement mortar | | |
| | infill and all necessary fixing and | | |
| | jointing materials and accessories as | | |
| | specified with 5mm thick clear sheet | | |
| | float glass. | | |
| | | | |
| A323 | Repair to mild steel casement window | light | 7.70 | A323
| | frame, sash and hinges including all | | |
| | necessary cutting, welding, refixing of | | |
| | glass panel and painting to match | | |
| | existing. | | |
| | | | |
| | * 1.2mm thk aluminium extruded frame | | |
| | top-hung window complete with glass, | | |
| | aluminium framing, ironmongery and | | |
| | cill with cement mortar infill and | | |
| | sealant joint and fixing accessories | | |
| | as specified: *(A324 A327) | | |
| | | | |
| A324 | Natural anodised with 5mm thick float | m2 | 219.80 | A324
| | clear glass | | |
| | | | |
| A325 | Natural anodised with 5mm thick float | m2 | 235.60 | A325
| | tinted glass | | |
| | | | |
| A326 | Bronze anodised with 5mm thick float | m2 | 268.10 | A326
| | clear glass | | |
| | | | |
| A327 | Bronze anodised with 5mm thick float | m2 | 283.90 | A327
| | tinted glass | | |
| | | | |
| | * 1.2mm thk aluminium extruded | | |
| | framed fixed window panel c/o glass, | | |
| | aluminium framing, ironmongeries, cill, | | |
| | cement mortar infill, sealant joint. | | |
| | *(A328 A331) | | |
| | | | | Bldg Tc
| A328 | Powder-coated with 5mm thick clear | m2 | 278.70 | A328
| | float glass | | |
| | | | |
| A329 | Natural anodised with 5mm thick clear | m2 | 179.50 | A329
| | float glass | | |
| | | | |
| A330 | Bronze anodised with 5mm thick clear | m2 | 217.30 | A330
| | float glass | | |
| | | | |
| A331 | Bronze anodised with 5mm thick tempered | m2 | 231.80 | A331
| | glass | | |
| | | | | Bldg Tc

PAGE 28 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | STRUCTURAL STEELWORK & METALWORK | | |
| | (CONT'D) | | |
| | | | |
| A332 | Stainless steel stair nosing size 50mm | m | 11.35 | A332
| | x 35mm x 0.8mm thick of grade 304 bedded | | |
| | in cement mortar 1:3. | | |
| | | | | Bldg Tc
| A333 | 1100mm height fluorocarbon coated | m | 202.00 | A333
| | fluorocarbon coated alum sun breaker. | | |
| | | | | Bldg Tc
| A334 | 1.0m high stainless steel railing | m | 307.90 | A334
| | c/o 50mm dia X 2mm thick pipe | | |
| | as top rail, intermediate, bottom rail | | |
| | and the same for baluster but @ 1.2m | | |
| | c/c, infilled with 12mm dia, x 1.2mm | | |
| | thick s/s pipe @ 100mm c/c cast in | | |
| | concrete | | |
| | | | | Bldg Tc
| A335 | 38mm diameter stainless steel handrail | m | 109.75 | A335
| | complete with end flanges, covers and | | |
| | fixing accessories. | | |
| | | | | Bldg Tc
| A336 | Rubberised bollard (Black) 152mm | no | 386.40 | A336
| | diameter x 900mm height complete | | |
| | with mild steel cover to conceal bolts. | | |
| | | | | Bldg Tc
| A337 | 100mm diameter x 6mm thick mild steel | no | 92.50 | A337
| | hollow section bollards with 200mm of | | |
| | its length encased in 350 x 350 x 350mm | | |
| | deep grade 20 concrete foundation and | | |
| | 900mm of its length above ground level | | |
| | complete with 6mm thick end cap and 200 x | | |
| | 200 x 6mm thick base plate with | | |
| | stiffener including all necessary welding | | |
| | and painting with 1 primer coat and two | | |
| | coats of enamel paint. | | |
| | | | | Bldg Tc
| A338 | 6mm diameter galvanised chain to | m | 2.95 | A338
| | bollards including all fixtures. | | |
| | | | | Bldg Tc
| A339 | Supply and install 10mm galvanised | m | 4.85 | A339
| | linkchain complete with D-shackles and | | |
| | clear PVC tubing. | | |
| | | | | Bldg Tc
| A340 | 256 x 256mm galvanised steel lightning | no | 4.40 | A340
| | conductor pit cover complete with a 12mm | | |
| | diameter hole and hinges. | | |
| | | | | Bldg Tc
| A341 | Supply of cylinder oxygen | no | 18.20 | A341
| | | | | Bldg Tc
| A342 | Supply of cylinder acetylene | no | 54.40 | A342
| | | | |

PAGE 29 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SIGNAGES | | |
| | | | | Bldg Tc
| A343 | Plastic unit number plate 40 x 60mm per | no | 1.20 | A343
| | digit | | |
| | | | | Bldg Tc
| A344 | 700 x 200 x 2mm thick directional | no | 35.60 | A344
| | aluminium sign plate fixed to wall with | | |
| | approved stainless steel screws and | | |
| | plugs. | | |
| | | | | Bldg Tc
| A345 | 200mm (H) street name sign consisting | no | 345.35 | A345
| | of 2mm thick aluminium plate of Engr's | | |
| | grade reflective sheet with vinyl film | | |
| | non reflective alphabets/nos on both | | |
| | face, 50.8 x 50.8 x 4mm Galvanised | | |
| | SHS pole and 350 x 350 x 500mm G20 | | |
| | concrete foundation. | | |
| | | | |
| | * 2mm thick natural aluminium sign plate | | |
| | with helvetica letters, numbers, | | |
| | symbols, logo etc engraved/embossed in | | |
| | approved colour including stainless | | |
| | steels fixing screws/bolts to walls | | |
| | /post. *(A346 A347) | | |
| | | | | Bldg Tc
| A346 | Not exceeding 0.10m2 | m2 | 416.65 | A346
| | | | | Bldg Tc
| A347 | Exceeding 0.10m2 | m2 | 378.00 | A347
| | | | | Bldg Tc
| A348 | 2mm (14 SWG) sign plate with high | m2 | 351.45 | A348
| | intensity grade reflective sheet, | | |
| | letterings, figures and graphics mounted | | |
| | to one face installed to wall/post etc | | |
| | including stainless steel fixing screws/ | | |
| | bolts. (Post measured separately) | | |
| | | | | Bldg Tc
| A349 | 3mm thick aluminium HDB standard sign | m2 | 241.70 | A349
| | sign plate consisting of embossed block | | |
| | number and lift emergency number of | | |
| | approved colour to lift lobby walls | | |
| | including stainless steel fixing | | |
| | screws/bolts. | | |
| | | | | Bldg Tc
| A350 | 3mm thick aluminium sign plate with | m2 | 268.20 | A350
| | embossed and reflective paintwork | | |
| | (yellow letterings/numbers with black | | |
| | background) including stainless steel | | |
| | fixing screws/bolts. | | |
| | | | | Bldg Tc
| A351 | 300x400mm aluminium standard danger | no | 16.40 | A351
| | warning sign plate for 415V consumer | | |
| | switchroom with approved silkscreen | | |
| | vinyl. | | |
| | | | | Bldg Tc

PAGE 30 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SIGNAGES (CONT'D) | | |
| | | | |
| A352 | 1.5mm thk stainless steel lift notice | m2 | 251.20 | A352
| | plate with helvetica letters, numbers, | | |
| | symbols, logo etc engraved/embossed in | | |
| | approved colour including stainless | | |
| | steels fixing screws/bolts to walls at | | |
| | lift lobby. | | |
| | | | |
| | * Aluminium 'Box' lettering with black | | |
| | matt finish paint. *(A353 A356) | | |
| | | | | Bldg Tc
| A353 | 25mm thick (150mm - 250mm height) | no | 72.45 | A353
| | | | | Bldg Tc
| A354 | 30mm thick (>250mm - <350mm height) | no | 130.40 | A354
| | | | | Bldg Tc
| A355 | 30mm thick (>350mm & <400mm height) | no | 157.70 | A355
| | | | | Bldg Tc
| A356 | 30mm thick (>400mm & <500mm height) | no | 185.10 | A356
| | | | |
| | * Acrylic sign plate of approved design | | |
| | c/o graphics, text(alphabets, numerals), | | |
| | logo, colours etc with approved stickers | | |
| | or spray paint including fixing | | |
| | stainless steel screws/bolts and | | |
| | accessories. *(A357 A361) | | |
| | | | | Bldg Tc
| A357 | 2mm thick (not exceeding 0.10m2) | m2 | 201.60 | A357
| | | | | Bldg Tc
| A358 | 2mm thick (exceeding 0.10m2) | m2 | 182.40 | A358
| | | | | Bldg Tc
| A359 | 3mm thick (not exceeding 0.10m2) | m2 | 266.10 | A359
| | | | | Bldg Tc
| A360 | 3mm thick (exceeding 0.10m2) | m2 | 241.50 | A360
| | | | | Bldg Tc
| A361 | 10mm thick | m2 | 903.55 | A361
| | | | | Bldg Tc
| A362 | 5mm thick acrylic lift information | m2 | 285.60 | A362
| | sign plate of approved design in 4 | | |
| | languages c/o approved sticker or | | |
| | spray paint including stainless | | |
| | steel fixing screws and accessories. | | |
| | | | | Bldg Tc
| A363 | 6mm acrylic sheet signage with bend | m2 | 782.70 | A363
| | edges c/o approved sticker of building | | |
| | layout plan in approved colour at lift | | |
| | lobby including stainless steel fixing | | |
| | screws/bolts. | | |
| | | | | Bldg Tc
| A364 | 10mm thick "Ultimate Flexi Sign" | m2 | 1,166.35 | A364
| | perplex sign plate c/o text/text | | |
| | (alphabets, numerals, etc.) in approved | | |
| | colour, stainless steel fixing screws | | |
| | and accessories. | | |
| | | | | Bldg Tc

PAGE 31 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SIGNAGES (CONT'D) | | |
| | | | |
| A365 | Red colour triangle fire access | no | 6.60 | A365
| | sticker (approved by FSSB) | | |
| | | | | Bldg Tc
| A366 | Vinyl sticker of approved waterproof | m2 | 144.90 | A366
| | type with graphics, letters, numbers, | | |
| | symbols etc to sign plate. | | |
| | | | | Bldg Tc
| A367 | Vinyl sticker of approved waterproof | m2 | 181.15 | A367
| | type with 'cut-out' letterings, numbers, | | |
| | symbols etc to sign plate (Measurement | | |
| | shall be by the perimeter of the | | |
| | complete set of the 'cut-out'). | | |
| | | | | Bldg Tc
| A368 | Update directory signs for new tenant | no | 10.50 | A368
| | complete with Unit Nos and Company's | | |
| | Name including removal of redundant | | |
| | signs if any. The types, size and | | |
| | numbers of alphabets and numerals shall | | |
| | be to match existing and regardless of | | |
| | the numbers of alphabets or numerals and | | |
| | the type of design and material used. | | |
| | | | |
| A369 | Remove aluminium plate (any size) | no | 10.60 | A369
| | from walls and return to HDB office | | |
| | on instruction of SO's Representatives | | |
| | including making good works disturbed. | | |
| | | | | Bldg Tc
| A370 | 50 x 50 x 4mm thick mild steel square | no | 84.40 | A370
| | hollow section stand (2.20m from ground | | |
| | level to underside of signboard and 0.5m | | |
| | below ground level) with 200 x 200 x 6mm | | |
| | thick base plate welded to stand, | | |
| | 350 x 350 x 450mm Concrete (grade 20) | | |
| | foundation including fixing accessories. | | |
| | | | | Bldg Tc
| A371 | 1140(L)x840(H)mm notice board | no | 386.40 | A371
| | 'Gleason' or other approved equivalent | | |
| | at lift lobby. | | |
| | | | |
| | ROOFING | | |
| | | | | Bldg Tc
| A372 | RN 3315 to roof to support | m2 | 3.05 | A372
| | sisalation paper. | | |
| | | | | Bldg Tc
| A373 | 50mm thick Fibreglass (Building Grade) | m2 | 5.80 | A373
| | insulation to roof. | | |
| | | | | Bldg Tc
| A374 | Sisalation 420 double sided aluminium | m2 | 4.60 | A374
| | foil. | | |
| | | | |

PAGE 32 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | ROOFING (CONT'D) | | |
| | | | |
| | * Rock/Mineral Wool roofing insulation | | |
| | including fixing accessories to roof : | | |
| | *(A375 A378) | | |
| | | | | Bldg Tc
| A375 | 50mm thick (40kg/m3) | m2 | 10.30 | A375
| | | | | Bldg Tc
| A376 | 50mm thick (50kg/m3) | m2 | 11.55 | A376
| | | | | Bldg Tc
| A377 | 50mm thick (60kg/m3) | m2 | 12.40 | A377
| | | | | Bldg Tc
| A378 | 50mm thick (80kg/m3) | m2 | 15.35 | A378
| | | | | Bldg Tc
| A379 | 50mm thick poly fibreglass wool blanket | m2 | 3.40 | A379
| | (Density: 10kg/m3) to underside of metal | | |
| | roof | | |
| | | | |
| A380 | 0.47mm thick colourbond Spandek Hi-Ten | m2 | 33.80 | A380
| | metal roofing sheets including all | | |
| | necessary accessories as specified. | | |
| | | | |
| A381 | 0.47mm thick 'Multi-deck XRW' | m2 | 33.20 | A381
| | colourbond roofing sheet including all | | |
| | fixing accessories (including provision | | |
| | of 10 years warranty) | | |
| | | | |
| A382 | 0.53mm thick colourbond Kliplok Hi-Ten | m2 | 40.50 | A382
| | metal roofing sheets including all | | |
| | necessary accessories as specified. | | |
| | | | |
| A383 | 0.6mm thick colourbond Klip-lok metal | m2 | N.A |
| | roofing sheets including all necessary | | |
| | accessories as specified | | |
| | | | |
| A384 | 0.65mm thick colourbond Kliplok Hi-Ten | m2 | 47.50 | A384
| | metal roofing sheets including all | | |
| | necessary accessories as specified. | | |
| | | | |
| A385 | 0.47mm thick colourbond V-Crimp Hi-Ten | m2 | 30.60 | A385
| | metal fascia sheets including all | | |
| | necessary fixing accessories as | | |
| | specified. | | |
| | | | |
| A386 | 0.6mm thick Speed deck 508 colorbond | m2 | 46.80 | A386
| | XRW metal roofing sheets including | | |
| | all necessary accessories as specified | | |
| | | | |
| A387 | 0.60mm thick colourbond standard ridge | m | 19.10 | A387
| | capping to Kliplok roofing including all | | |
| | necessary fixing accessories as | | |
| | specified. | | |
| | | | |

PAGE 33 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | ROOFING (CONT'D) | | |
| | | | |
| A388 | 0.53mm thick custom made colourbond | m2 | 22.90 | A388
| | flashings/cappings/trims to Kliplok | | |
| | roofing including all necessary fixing | | |
| | accessories as specified. | | |
| | | | | Bldg Tc
| A389 | 0.8mm thick PVF2 coated Rannila 45J | m2 | 39.90 | A389
| | roof sheet including fixing accessories | | |
| | | | | Bldg Tc
| A390 | 0.8mm thick PVF2 coated panel to | m | 21.75 | A390
| | eave/verge flashings including fixing | | |
| | accessories (350mm girth) | | |
| | | | | Bldg Tc
| A391 | 50mm thick poly fibreglass wool blanket | m2 | 3.35 | A391
| | reflective roof heat insulation sheet | | |
| | including lapping with 'Parsec Thermo | | |
| | brite' tape and secured to roof | | |
| | structure by self-drilling fasteners | | |
| | with metal washers in accordance with | | |
| | manufacturer's instructions. | | |
| | | | | Bldg Tc
| A392 | Lay one layer of 'Super-Brite' | m2 | 6.95 | A392
| | radiant vapour barrier reflective roof | | |
| | heat insulation sheet including lapping | | |
| | with PPC 493 reinforced aluminium foil | | |
| | tape and secured to roof structure by | | |
| | self-drilling fasteners complete with | | |
| | metal washers as specified and in | | |
| | accordance with Manufacturer's | | |
| | instructions. | | |
| | | | |
| A393 | Labour to take out and reinstall | m2 | 3.10 | A393
| | existing roofing sheets including | | |
| | provision of approved new fixing | | |
| | accessories if any for the replacement | | |
| | of insulation system. | | |
| | | | | Bldg Tc
| A394 | Lay tarpaulin to roof damaged by fire | m2 | 1.70 | A394
| | including timber battens and fixing | | |
| | accessories to hold down tarpaulin. | | |
| | | | | Bldg Tc
| A395 | Felt roll to roof including fixing | m2 | 1.90 | A395
| | screws. | | |
| | | | |

PAGE 34 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | ROOFING (CONT'D) | | |
| | | | |
| | * 20 Gauge(0.914mm) galvanised steel | | |
| | rain-water eaves gutters fabricated and | | |
| | fixed including all necessary fixing | | |
| | accessories, painting one coat of | | |
| | approved zinc chromate to all surfaces | | |
| | and one coat of approved water-proofing | | |
| | coating to the internal surface of the | | |
| | gutter and 1 primer coat and 1 finishing | | |
| | coat of enamel paint externally (mild steel | | |
| | brackets measured separately) | | |
| | *(A396 A399) | | |
| | | | | Bldg Tc
| A396 | Not exceeding 0.5m girth. | m | 18.40 | A396
| | | | | Bldg Tc
| A397 | Exceeding 0.5m but not exceeding | m | 24.40 | A397
| | 0.75m girth. | | |
| | | | | Bldg Tc
| A398 | Exceeding 0.75m but not exceeding | m | 28.70 | A398
| | 1.00m girth. | | |
| | | | | Bldg Tc
| A399 | Exceeding 1.00m but not exceeding 2.00m | m | 34.45 | A399
| | girth. | | |
| | | | |
| | * 1mm thick approved 'zincalume' gutters | | |
| | fabricated and fixed including fixing | | |
| | accessories, painting one coat of | | |
| | approved zinc chromate to all surfaces | | |
| | and one coat of approved waterproof | | |
| | coating to internal surface of the | | |
| | gutter and 1 primer coat and 1 finishing | | |
| | coat of enamel paint externally (mild | | |
| | steel brackets measured separately) | | |
| | *(A400 A403) | | |
| | | | | Bldg Tc
| A400 | Not exceeding 0.5m girth | m | 27.10 | A400
| | | | | Bldg Tc
| A401 | Exceeding 0.5m but not exceeding 0.75m | m | 46.30 | A401
| | girth | | |
| | | | | Bldg Tc
| A402 | Exceeding 0.75m but not exceeding 1.00m | m | 59.45 | A402
| | girth | | |
| | | | | Bldg Tc
| A403 | Exceeding 1.00m but not exceeding 2.00m | m | 87.05 | A403
| | girth | | |
| | | | | Bldg Tc
| A404 | 150mm diameter gauge 16 half-round | m | 19.75 | A404
| | galvanised steel rainwater eaves gutters | | |
| | including brackets and all necessary | | |
| | fixing accessories, painting internally | | |
| | with 1 coat approved waterproofing | | |
| | coatings and 1 primer coat and 1 | | |
| | finishing coat of enamel paint | | |
| | externally | | |

PAGE 35 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | ROOFING (CONT'D) | | |
| | | | | Bldg Tc
| A405 | Repair to leaking metal roof/gutter | m2 | 8.10 | A405
| | with approved polyurethane sealant to | | |
| | all bolt heads and leaking joints/gaps | | |
| | and apply 'Emer Clad' or other approved | | |
| | waterproofing coatings with minimum | | |
| | thickness of 300 microns to surfaces | | |
| | of roof/internal of gutter. | | |
| | | | |
| | * Labour for refixing and repair lose | | |
| | flashing including all necessary | | |
| | additional drive screws *(A406 A407) | | |
| | | | |
| A406 | Not exceeding 300mm girth. | m | 2.80 | A406
| | | | |
| A407 | Exceeding 300mm girth. | m | 3.80 | A407
| | | | |
| A408 | Repair to loose/dented metal roof | m2 | 3.80 | A408
| | flashing/facia including approved fixing | | |
| | screws/accessories | | |
| | | | |
| A409 | Remove existing gutter, brackets, RWDP, | m | 3.80 | A409
| | holders etc including cutting, cart away | | |
| | and make good disturbed areas to match | | |
| | existing (Rate include dumping fees & | | |
| | stagging) | | |
| | | | | Bldg Tc
| A410 | Lay 600 x 600 x 30mm thick ferrocement | m2 | 27.30 | A410
| | secondary roof slabs, reinforced with | | |
| | galvanised welded fabric to concrete | | |
| | flat roof including all necessary | | |
| | supporting concrete solid block | | |
| | (Hoisting by crane shall be measured | | |
| | separately). | | |
| | | | | Bldg Tc
| A411 | Apply a complete Waterproofing Membrane | m2 | 8.10 | A411
| | System to concrete flat roof | | |
| | consisting of 6 coats of waterproofing | | |
| | membranes, 1 layer of fibre glass | | |
| | membrane and 1 coat of bituminous | | |
| | aluminium finishing paint as specified; | | |
| | complying with SS133:1987 and in | | |
| | accordance with manufacturer's | | |
| | instructions | | |
| | | | | Bldg Tc
| A412 | Panel Roofing System to roof surfaces | m2 | 52.50 | A412
| | consisting of 38mm thick waterproofing | | |
| | cement and sand panel (1:3), 50mm thick | | |
| | 'Roofmate' insulation board, 6 coats of | | |
| | waterproofing membranes, 1 layer of | | |
| | fibre glass membrane and a minimum of | | |
| | 20mm thick waterproofing cement sand | | |
| | screed (1:3) laid to fall | | |

PAGE 36 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | | | |
| | ROOFING (CONT'D) | | |
| | | | | Bldg Tc
| A413 | Removal of existing waterproofing | m2 | 5.25 | A413
| | bituminous membrane, stools and | | |
| | secondary slabs and prepare surfaces to | | |
| | receive new membrane including hoisting | | |
| | down debris and disposal. | | |
| | | | | Bldg Tc
| A414 | Removal of existing waterproofing | m2 | 2.20 | A414
| | membrane and prepare surfaces to receive | | |
| | new membrane including hoisting down | | |
| | debris and disposal. | | |
| | | | |
| A415 | Temporary removal of existing precast | m2 | 1.30 | A415
| | concrete secondary roof slab and support | | |
| | to facilitate repair works and relay the | | |
| | existing precast concrete secondary roof | | |
| | slab and support upon completion | | |
| | on repair works. | | |
| | | | | Bldg Tc
| A416 | Concrete ridge tiles (all colours) in | no | 11.80 | A416
| | repairs including stripping off existing | | |
| | and removing debris off site. | | |
| | | | |
| A417 | Patch up nail holes in corrugated | no | 0.30 | A417
| | roofing sheets with mastic and one layer | | |
| | of bituminous felt. | | |
| | | | | Bldg TC
| A418 | Rake out bitumen or other compounds | m | 8.30 | A418
| | from existing roof expansion joints and | | |
| | refill with approved sealing compound | | |
| | including backer rod. | | |
| | | | | Bldg TC
| A419 | G20 (0.914mm thick) purpose-made | m | 6.60 | A419
| | aluminium expansion joint cover not | | |
| | exceeding 500mm girth with "V" shaped | | |
| | groove in centre including fixing with | | |
| | stainless steel screws and washers | | |
| | | | |
| | WALL AND CEILING FINISHES | | |
| | | | |
| A420 | Hack off wall finishes, form keys, | m2 | 4.00 | A420
| | clean and wash to receive new finishes | | |
| | including cart away debris | | |
| | to dumping ground | | |
| | | | |
| | * 18mm thick plaster with approved | | |
| | prepacked mortar mix in 2 coats to wall: | | |
| | *(A421 A422) | | | Jan 06'
| | | | | Bldg SOR
| A421 | Applied from within building | m2 | 12.70 | S/n 666
| | | | | Jan 06'
| A422 | Applied from external of building | m2 | 14.60 | Bldg SOR
| | | | | S/n 667

PAGE 37 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | WALL AND CEILING FINISHES (CONT'D) | | |
| | | | |
| | * Skim coat with approved skimming | | |
| | material. *(A423 A426) | | |
| | | | | Bldg Tc
| A423 | Wall (from within building) | m2 | 3.45 | A423
| | | | | Bldg Tc
| A424 | Ceiling (from within building) | m2 | 3.70 | A424
| | | | | Bldg Tc
| A425 | Wall (from external of building) | m2 | 4.10 | A425
| | | | | Bldg Tc
| A426 | Sides and soffit of beams and slabs | m2 | 4.30 | A426
| | (from external of building) | | |
| | | | | Bldg Tc
| A427 | Exmet mesh to wall | m2 | 3.80 | A427
| | | | |
| | * Wall tiles of approved colours, | | |
| | patterns and textures including | | |
| | prepacked mortar screed as specified. | | |
| | *(A428 A429) | | |
| | | | |
| A428 | 7mm thick white glazed ceramic tiles | m2 | 28.80 | A428
| | | | | Bldg Tc
| A429 | 8mm thk glazed wall tiles (SS301.1985) | m2 | 34.15 | A429
| | | | |
| A430 | 9mm thk homogeneous wall tiles as | m2 | 42.10 | A430
| | specified including grinding down of | | |
| | sharp corners to a rounded edge and | | |
| | prepacked mortar screed as specified. | | |
| | | | |
| A431 | Re-pointing joints of existing wall | m2 | 1.60 | A431
| | tiling in white cement including | | |
| | cleaning surface on completion. | | |
| | | | | Bldg Tc
| A432 | 200 x 100mm thick natural | m | 144.90 | A432
| | rubber bumper to wall | | |
| | of loading/unloading bay | | |
| | including all approved fixing | | |
| | accessories | | |
| | | | |
| | * 1200mm high rubber protection guard | | |
| | fabricated to corners of wall/column | | |
| | complete with 20 nos. of stainless steel | | |
| | (SUS304) HPS capsule boltings. | | |
| | *(A433 A434) | | |
| | | | | Bldg Tc
| A433 | 75 x 75 x 10mm thick. | no | 24.15 | A433
| | | | | Bldg Tc
| A434 | 100 x 100 x 10mm thick. | no | 36.25 | A434
| | | | | Bldg Tc
| A435 | 150mm width x 30mm thick natural | m | 44.65 | A435
| | rubber bumper to skirting areas of lift | | |
| | lobby including all approved fixing | | |
| | accessories. | | |
| | | | |

PAGE 38 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | WALL AND CEILING FINISHES (CONT'D) | | |
| | | | | Bldg Tc
| A436 | 1200mm height rubber protection guard | no | 36.25 | A436
| | of size 75 x 75 x 6mm thick to corners | | |
| | of wall /column complete with 10 Nos of | | |
| | galvanised steel HPS capsule boltings. | | |
| | | | | Bldg Tc
| A437 | Rubberised Studded Band including | m | 48.30 | A437
| | including all fixing accessories. | | |
| | | | | Bldg Tc
| A438 | Remove bolts, and anchor stud of | no | 0.40 | A438
| | fixtures below concrete/plaster surface | | |
| | including patch up holes with approved | | |
| | non-shrink cement grout including | | |
| | necessary painting to match existing. | | |
| | | | |
| | * Boards to ceiling/wall etc. (Frames | | |
| | measured separately) *(A439 A443) | | |
| | | | | Bldg Tc
| A439 | 6mm thick fibre reinforced cement board. | m2 | 7.75 | A439
| | | | | Bldg Tc
| A440 | 10mm thick fibre reinforced cement | m2 | 11.90 | A440
| | board. | | |
| | | | | Bldg Tc
| A441 | 12mm thick fibre reinforced cement | m2 | 12.90 | A441
| | board. | | |
| | | | | Bldg Tc
| A442 | 10mm thick gypsum board. | m2 | 5.15 | A442
| | | | | Bldg Tc
| A443 | 12mm thick mineral fibre board. | m2 | 8.60 | A443
| | | | | Bldg Tc
| A444 | 9.5mm thk approved gypsum ceiling | m2 | 11.55 | A444
| | boards including suspension | | |
| | system (exclude removal of existing | | |
| | suspended ceiling). | | |
| | | | | Bldg Tc
| A445 | 600x600x15mm thick 'Armstrong' | m2 | 40.95 | A445
| | pin dot mineral fibre ceiling on | | |
| | exposed white T-grid c/w hangar rod | | |
| | and clips | | |
| | | | | Bldg Tc
| A446 | Aluminium approved patterned | m2 | 43.50 | A446
| | recessed panel ceiling of grid | | |
| | 600x600x0.7mm thick clip-in panel | | |
| | concealed joint and powder coated to | | |
| | colour. The ceiling shall consist of | | |
| | bevelled edged tiles fixed to an | | |
| | adjustable suspension system. | | |
| | | | | Bldg Tc

PAGE 39 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | WALL AND CEILING FINISHES (CONT'D) | | |
| | | | |
| A447 | 0.8mm thick fluorocarbon/electrostatic | m2 | 48.30 | A447
| | powder coated 'Dampa-Tile' 600 x 600mm | | |
| | aluminium ceiling c/o combination | | |
| | aluminium plain flat and perforated | | |
| | ceiling tiles, approved metal suspended | | |
| | system and fixing accessories. | | |
| | | | | Bldg Tc
| A448 | Grid suspension system (600 x 1200mm | m2 | 6.50 | A448
| | grid) c/o 'T'/'L' shaped galvanised | | |
| | steel strips not exceeding 30mm wide as | | |
| | fillet for false ceiling including | | |
| | hanging lines. | | |
| | | | | Bldg Tc
| A449 | Labour, tools and mobile scaffold if | m2 | 1.05 | A449
| | necessary to remove suspended ceiling | | |
| | including make good disturbed area, cart | | |
| | away and disposal. | | |
| | | | |
| | PAINTING AND DECORATING | | |
| | | | |
| | * Painting surfaces of wood and | | |
| | metal surfaces with synthetic enamel | | |
| | paint including preparation of surfaces | | |
| | *(A450 A451) | | |
| | | | |
| A450 | One finishing coat. | m2 | 1.60 | A450
| | | | |
| A451 | One undercoat and one finishing coat. | m2 | 2.70 | A451
| | | | | Bldg Tc
| A452 | Prepare and apply one coat 'Co-Seal' | m2 | 2.40 | A452
| | fleck coat base and finishing coat of | | | Out of Pr
| | 'Co-Seal' econocoat plastic emulsion | | |
| | paint to internal wall and ceiling | | |
| | | | | Bldg Tc
| A453 | Prepare and apply one coat 'Co-Seal' | m2 | 13.15 | A453
| | binder/sealer, one undercoat of | | | Out of Pr
| | 'Co-Seal' liquid plastic dressing and | | |
| | one finishing coat of 'Co-Seal' liquid | | |
| | plastic dressing to plastered external | | |
| | wall | | |
| | | | |
| A454 | Brush or wash down and apply 2 pack | m2 | 3.60 | A454
| | mix polyurethane paint (non-metallic | | |
| | finishes) on concrete or plastered | | |
| | surface | | |
| | | | | Bldg Tc
| A455 | Brush or wash down and apply | m2 | 10.30 | A455
| | polyurethane enamel paint c/o ; | | |
| | 1 coat of amino epoxy zinc phospate | | |
| | blast primer, amine epoxy matt, 2 pack | | |
| | polyurethane undercoat and 2 pack | | |
| | polyurethane finishing coat to steelwork | | |
| | | | | Bldg Tc

PAGE 40 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | PAINTING AND DECORATING (CONT'D) | | |
| | | | |
| A456 | Remove rust, clean down and apply one | m2 | 4.60 | A456
| | coat approved rust convertor to metal | | |
| | surfaces. | | |
| | | | |
| A457 | Clean and paint one coat zinc chromate | m2 | 1.20 | A457
| | primer to metal surfaces. | | |
| | | | |
| A458 | Clean down, knotted stopped, sand | m2 | 1.40 | A458
| | papered smooth and prime one coat | | |
| | aluminium primer to wood surfaces | | |
| | | | |
| A459 | One coat red primer (anti-corrosive) | m2 | 1.60 | A459
| | Type 'C' to metal surfaces including | | |
| | preparation of surfaces as specified. | | |
| | | | | Bldg Tc
| A460 | Remove rust, clean down and apply one | m2 | 3.05 | A460
| | coat approved cold zinc galvanise paint | | |
| | (glossy type) to metal surfaces. | | |
| | | | | Bldg Tc
| A461 | One coat approved epoxy paint to metal | m2 | 2.30 | A461
| | surfaces. | | |
| | | | |
| A462 | Painting to both faces with one | m2 | 2.00 | A462
| | finishing coat synthetic enamel | | |
| | paint including preparation of | | |
| | surfaces as specified. (Measured | | |
| | flat on its elevation surface) | | |
| | Metal grilles/staircase railings | | |
| | | | | Bldg Tc
| A463 | One coat approved oil base luminous | m2 | 4.50 | A463
| | paint to concrete /metal surfaces. | | |
| | | | |
| | * Painting pipes, railing, etc. with | | |
| | synthetic enamel paint including | | |
| | preparation of surfaces as specified. | | |
| | *(A464 A467) | | |
| | | | |
| A464 | One finishing coat (not exceeding 75mm | m | 0.40 | A464
| | diameter). | | |
| | | | |
| A465 | One undercoat and one finishing coat. | m | 0.70 | A465
| | (not exceeding 75mm diameter). | | |
| | | | |
| A466 | One finishing coat. (Exceeding 75mm | m | 1.10 | A466
| | diameter and not exceeding 150mm | | |
| | diameter). | | |
| | | | |
| A467 | One undercoat and one finishing coat. | m | 1.90 | A467
| | (exceeding 75mm and not exceeding | | |
| | 150mm diameter). | | |
| | | | |

PAGE 41 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | PAINTING AND DECORATING (CONT'D) | | |
| | | | |
| | * Brush with steel wire brush to remove | | |
| | all rust, prepare and paint two coats | | |
| | approved bituminous paint to pipe | | |
| | surfaces *(A468 A470) | | |
| | | | | Bldg Tc
| A468 | Not exceeding 75mm diameter | m | 1.05 | A468
| | | | | Bldg Tc
| A469 | Exceeding 75mm diameter but not | m | 2.00 | A469
| | exceeding 150mm diameter | | |
| | | | | Bldg Tc
| A470 | Exceeding 150mm diameter but not | m | 4.00 | A470
| | exceeding 300mm diameter | | |
| | | | |
| | * Painting metal lamp guard and | | |
| | fluorescent tube casing with one | | |
| | finishing coat synthetic enamel | | |
| | paint. *(A471 A472) | | |
| | | | |
| A471 | 600mm long. | no | 1.90 | A471
| | | | |
| A472 | 1200mm long. | no | 2.60 | A472
| | | | |
| A473 | Painting one finishing coat aluminium | no | 0.30 | A473
| | paint to metal adjustable louvred window | | |
| | blades. (Rate inclusive of painting to | | |
| | both faces) | | |
| | | | |
| A474 | Painting one finishing coat aluminium | m2 | 3.20 | A474
| | paint to metal collapsible gates. | | |
| | (Measured flat over area of gates. Rate | | |
| | inclusive of painting to both faces). | | |
| | | | |
| A475 | Prepare and paint one coat of aluminium | m | 0.40 | A475
| | paint to adjustable louvered frame (Both | | |
| | faces). | | |
| | | | |
| | * Paint approved acrylic emulsion paint | | |
| | to surfaces of walls, ceilings, columns, | | |
| | etc including preparing surfaces as | | |
| | specified. *(A476 A477) | | |
| | | | |
| A476 | One finishing coat (without dilution). | m2 | 1.00 | A476
| | | | |
| A477 | One under coat (with 20% dilution) | m2 | 1.80 | A477
| | and one finishing coat(without dilution) | | |
| | | | |
| A478 | Brush, wash down and apply one coat | m2 | 1.15 | A478
| | water-based sealer on concrete or | | |
| | plastered surfaces. | | |
| | | | | Bldg Tc

PAGE 42 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | PAINTING AND DECORATING (CONT'D) | | |
| | | | |
| A479 | One coat approved anti-bacteria paint | m2 | 3.70 | A479
| | 'Tuff-rex EP S680' or approved | | |
| | equivalent to wall. | | |
| | | | | Bldg Tc
| A480 | Two coat Shellac varnish to wood | m2 | 2.10 | A480
| | surfaces. | | |
| | | | |
| A481 | One coat approved bituminous paint to | m2 | 6.20 | A481
| | mild steel gratings (rate inclusive of | | |
| | both faces). | | |
| | | | |
| | GLAZING | | |
| | | | |
| | * Glass louvres with polished edges | | |
| | to metal/timber frames. *(A482 A483) | | |
| | | | |
| A482 | 6mm thick clear glass. | m2 | 56.50 | A482
| | | | |
| A483 | 6mm thick obscured wired glass. | m2 | 66.00 | A483
| | | | |
| | * Glass panels to metal/timber casement | | |
| | windows and vents including putty | | |
| | and necessary accessories *(A484 A485) | | |
| | | | |
| A484 | 5mm thick clear glass. | m2 | 35.20 | A484
| | | | |
| A485 | 6mm thick clear glass. | m2 | 40.10 | A485
| | | | |
| A486 | Fix re-used glass louvred to adjustable | no | 0.90 | A486
| | louvred window/vent including removal of | | |
| | existing. | | |
| | | | |
| | FIRE EQUIPMENT | | |
| | | | | Bldg Tc
| A487 | Fire hose 'Miros Commander Super' or | no | 591.70 | A487
| | approved equivalent c/w 64mm diameter | | |
| | x 30m long, fibre glass casing with 75mm | | |
| | x 50mm galvanised 'C' channel. | | |
| | | | | Bldg Tc
| A488 | Hose reel cabinet overall size 800 x | no | 156.60 | A488
| | 800 x 400mm depth 16G electro-galvanised | | |
| | steel cabinet complete with red powder | | |
| | coating mounted to wall. | | |
| | | | | Bldg Tc
| A489 | Hydraulic double pivots hosereel drum | no | 154.35 | A489
| | of approved swing type c/w fixing | | |
| | accessories. | | |
| | | | | Bldg Tc
| A490 | 25mm diameter single braided hose | m | 4.95 | A490
| | approved by FSB complete with clips. | | |
| | | | | Bldg Tc
| A491 | Controllable discharge nozzle to 25mm | no | 25.50 | A491
| | diameter hose. | | |

PAGE 43 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | | | |
| | FIRE EQUIPMENT (CONT'D) | | |
| | | | | Bldg Tc
| A492 | 3mm thick clear glass to fire hosereel | m2 | 22.25 | A492
| | and fire extinguisher cabinet including | | |
| | fixing accessories (Frame measured | | |
| | separately) | | |
| | | | |
| | REINSTATEMENT OF WATER/ | | |
| | ELECTRICITY WORK | | |
| | | | | Bldg Tc
| A493 | Supply labour to remove, cut off | line | 27.30 | A493
| | supply, diversion and reinstatement of | | |
| | water supply within internal/outside | | |
| | unit.(additional new material used shall | | |
| | be measured separately) | | |
| | | | | Bldg Tc
| A494 | Supply labour to remove, diversion and | Point | 13.55 | A494
| | reinstatement of electrical (Lighting/ | | |
| | Power point) supply. (additional new | | |
| | material used shall be measured | | |
| | separately) | | |
| | | | | Bldg Tc
| A495 | Termination of electricity supply from | job | 27.00 | A495
| | tap-off unit to tenant's DB by licensed | | |
| | electrical worker including removal of | | |
| | cables, trunkings/conduits/trays and | | |
| | make good disturbed areas to match | | |
| | existing. | | |
| | | | | Bldg Tc
| A496 | Termination of electricity supply from | m | 7.80 | A496
| | HDB's switchroom to tenant's DB by licensed | | |
| | electrical worker including removal of | | |
| | cables, trunkings/conduits/trays and | | |
| | make good disturbed areas to match | | |
| | existing. | | |
| | | | | Bldg Tc
| A497 | Termination of electricity supply from | job | 204.00 | A497
| | tenant's stand-alone switch box by | | |
| | licensed electrical worker including | | |
| | removal of cables, trunkings/conduits/ | | |
| | trays and make good disturbed areas to | | |
| | match existing (Rate include submission | | |
| | of application to PowerGrid/Relevant | | |
| | Authorities and exclude removal of | | |
| | exposed cables, trunkings/trays etc) | | |
| | | | |

PAGE 44 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | CONCRETE REPAIR | | |
| | | | |
| A498 | Repair spalling concrete by patch | m2 | 46.60 | A498
| | with approved polymer modified | | |
| | sand-cement mortar as specified | | |
| | in Annex C-1 | | |
| | | | |
| A499 | Repair spalling concrete by patch | m2 | 171.40 | A499
| | repair with approved epoxy mortar | | |
| | as specified in Annex C-1. | | |
| | | | | Bldg Tc
| A500 | Repair spalling concrete by pressure | m2 | 147.75 | A500
| | grouting with non-shrink grout or other | | |
| | approved materials as specified | | |
| | Annex D-1. | | |
| | | | | Bldg Tc
| A501 | Repair cracks by epoxy injection as | m | 33.30 | A501
| | specified in Annex B-1. | | |
| | | | | Bldg Tc
| A502 | Patch repair cracks on walls/floors | m | 2.65 | A502
| | with non shrink grout 'Cem-Grout' or | | |
| | other approved equivalent including | | |
| | removal of loose materials, dirt and | | |
| | foreign matters. | | |
| | | | | Bldg Tc
| A503 | Hack 13mm "V" groove along crack, apply | m | 6.00 | A503
| | primer and patching with epoxy mortar | | |
| | as specified in Annex A-1. | | |
| | | | | Bldg Tc
| A504 | Hack 13mm "V" groove along crack and | m | 5.70 | A504
| | patch with acrylic compound or other | | |
| | approved flexible compound. | | |
| | Procedure as specified. | | |
| | | | |
| A505 | Hack 20mm "V" groove along crack and | m | 2.80 | A505
| | patch with 1:3 cement and sand mortar. | | |
| | | | |
| A506 | Patch cracks on walls/floors average | m | 0.80 | A506
| | not exceeding 25mm width with 1:3 cement | | |
| | and sand mortar including preparing | | |
| | cracks to receive mortar. | | |
| | | | | Bldg Tc
| A507 | Filling up gaps/pot holes with 1:3 | m3 | 156.15 | A507
| | cement and cement mortar including | | |
| | preparing gaps gaps/holes to receive | | |
| | mortar. | | |
| | | | | Bldg Tc
| A508 | Seal crack surfaces with polymer | m2 | 2.40 | A508
| | emulsion. | | |
| | | | |

PAGE 45 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | CONCRETE REPAIR (CONT'D) | | |
| | | | | Bldg Tc
| A509 | Apply approved acrylic protective | m2 | 3.50 | A509
| | coating to building component including | | |
| | removal of any flaking paintwork and | | |
| | painting to match. | | |
| | | | | Bldg Tc
| A510 | To erect timber shoring frames to | m3 | 154.45 | A510
| | columns and walls (including lateral | | |
| | bracings, base anchorings bolts) | | |
| | to HDB's approval. (Design & submission | | |
| | of drawings by Contractor's PE shall | | |
| | be paid separately if any) | | |
| | | | | Bldg Tc
| A511 | Supply labour, props and I-beam | job | 94.50 | A511
| | (X-sectional 150 x 100) including | | |
| | related accessories to prop up damaged | | |
| | beam including taking down. | | |
| | | | | Bldg Tc
| A512 | Supply, erect and dismantle approved | no | 0.10 | A512
| | steel props excluding timber support | | |
| | (per day) | | |
| | | | |
| | WATER SEEPAGE/LEAKAGE | | |
| | | | | Bldg Tc
| A513 | Expose the concrete surface, grind, | m2 | 23.75 | A513
| | dampen and apply crystalline | | |
| | waterproofing compound as specified in | | |
| | Annex H-1. | | |
| | | | | Bldg Tc
| A514 | Repair of water seepage through porous | m | 46.40 | A514
| | concrete by injecting approved water, | | |
| | reactive polyurethane based chemical | | |
| | grout as specified in Annex F-1. | | |
| | | | |
| | * Application of liquid-applied | | |
| | elastomeric waterproofing membrane | | |
| | inclusive of preparing the surfaces | | |
| | according to manufacturer's instructions | | |
| | *(A515 A516) | | |
| | | | | Bldg Tc
| A515 | Reinforced Concrete surface as | m2 | 11.75 | A515
| | specified in Clause 25.9 Technical | | |
| | Specification | | |
| | | | | Bldg Tc
| A516 | Hollow/Solid block wall as specified in | m2 | 16.80 | A516
| | Clause 25.8 Technical Specification | | |
| | (Water test measured separately) | | |
| | | | | Bldg Tc

PAGE 46 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | WATER SEEPAGE/LEAKAGE (CONT'D) | | |
| | | | |
| A517 | Repair to water leakage through floor | pt | 37.30 | A517
| | slab around sanitary piping/floor trap | | |
| | /fitting with water plug, bonding agent | | |
| | and make good the repaired area with | | |
| | waterproofed mortar and floor tiles to | | |
| | match with the existing floor tiles and | | |
| | bedding around pipe and as specified in | | |
| | Annex G-1. | | |
| | | | | Bldg Tc
| A518 | Repair to internal plaster/skim coat | m2 | 24.40 | A518
| | finished wall panel as specified Clause | | |
| | 49.39 Technical Specification (Vacuum | | |
| | blasting machine used measured | | |
| | separately) | | |
| | | | | Bldg Tc
| A519 | Apply silicone sealer to cracked joints | m | 1.60 | A519
| | between wooden frames and block/brick | | |
| | wall etc including brushing clean (for | | |
| | cracks not more than 5mm wide). | | |
| | | | | Bldg Tc
| A520 | Transportation (to/fro) and setting up/ | job | 46.30 | A520
| | dismantling of air compressor and vacuum | | |
| | blast machine. | | |
| | | | | Bldg Tc
| A521 | Rental of vacuum blast machine of fully | hr | 15.75 | A521
| | pneumatic size up to 2.5 m3/minute with | | |
| | blastmedia capacity 20 litres including | | |
| | compressor. | | |
| | | | | Bldg Tc
| A522 | Labour for vacuum blasting | m2 | 1.40 | A522
| | the wall including preparation of wall | | |
| | surfaces to receive new surfaces as | | |
| | specified. | | |
| | | | |
| | WATER/BUILDING COMPONENT TEST | | |
| | | | | Bldg Tc
| A523 | Conduct water test to the repaired areas | m2 | 0.95 | A523
| | by flooding of water with minimum depth | | |
| | of 25mm for 4 hour including | | |
| | construction of temporary water barrier | | |
| | approved by S.O. Representative and | | |
| | removal upon completion. (Rate inclusive | | |
| | of water fee) | | |
| | | | | Bldg Tc
| A524 | Watertightness test to external wall by | hr | 11.35 | A524
| | spraying water at 300 litres/hour as | | |
| | specified. (Rate inclusive of water fee) | | |
| | | | | Bldg Tc
| A525 | Watertightness test to external wall by | hr | 11.35 | A525
| | spraying water from a water hose with | | |
| | nozzle as specified. | | |
| | (Rate inclusive of water fees). | | |
| | | | |

PAGE 47 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | WATER/BUILDING COMPONENT TEST (CONT'D) | | |
| | | | | Bldg Tc
| A526 | Coring of concrete sample not exceeding | core | 124.45 | A526
| | 250mm diameter including transporting | | |
| | the sample to the laboratory as directed | | |
| | and reinstatement of core-hole to match | | |
| | existing upon completion of the test | | |
| | (testing fee to be paid separately). | | |
| | | | | Bldg Tc
| A527 | Rebound hammer test (12 readings | test | 42.30 | A527
| | per point) including exposing concrete | | |
| | surfaces, grinding and reinstatement | | |
| | works to match existing. | | |
| | | | | Bldg Tc
| A528 | Carbonation test ( 3 readings per | test | 30.25 | A528
| | point) including drilling of 10mm | | |
| | diameter hole into concrete spraying | | |
| | with indicator and reinstatement works | | |
| | to match existing upon completion of the | | |
| | test. | | |
| | | | | Bldg Tc
| A529 | Carbonation test to core sample by | test | 12.10 | A529
| | spraying phenolphthalein indicator. | | |
| | | | | Bldg Tc
| A530 | Extra over item A526 to A529 for | job | 120.75 | A530
| | mobilisation of equipment to carry out | | |
| | test on site. | | |
| | | | |
| | MISCELLANEOUS | | |
| | | | | Bldg Tc
| A531 | Supply and delivery to site incense | no | 53.25 | A531
| | paper burner fabricated from 44 gallon | | |
| | drum complete with hinged door, 2nos. | | |
| | 9mm dia. mild steel handles, 25mm dia. | | |
| | perforated holes at not more than 100mm | | |
| | c/c in 3 rows with 2210 galvanised mesh | | |
| | base netting supported by 4 legged stand | | |
| | and finished with 2 coats of red lead | | |
| | primer. | | |
| | | | |
| | * Labour and plant to cart away and | | |
| | dispose rubbish, furniture etc left | | |
| | behind by terminated tenant at approved | | |
| | dumping ground. Contractor shall | | |
| | required to submit original copy of the | | |
| | dumping receipt for weight above 0.5 ton | | |
| | *(A532 A538) | | |
| | | | |
| A532 | Not exceeding 0.5 ton | job | 49.40 | A532
| | | | |
| A533 | Exceeding 0.5 ton and not exceeding 1.5 | job | 203.60 | A533
| | ton | | |
| | | | |

PAGE 48 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | MISCELLANEOUS (CONT'D) | | |
| | | | |
| A534 | Exceeding 1.5 ton and not exceeding 2.5 | job | 292.10 | A534
| | ton | | |
| | | | |
| A535 | Exceeding 2.5 ton and not exceeding 3.5 | job | 380.70 | A535
| | ton | | |
| | | | |
| A536 | Exceeding 3.5 ton and not exceeding 4.5 | job | 469.20 | A536
| | ton | | |
| | | | |
| A537 | Exceeding 4.5 ton and not exceeding 5.5 | job | 557.80 | A537
| | ton | | |
| | | | |
| A538 | Total weightage exceeding 5.5 ton | ton | 117.30 | A538
| | | | | Bldg Tc
| A539 | Wash stained toilet floor, walls and | m2 | 0.90 | A539
| | windows/doors (both faces) including all | | |
| | sanitary fittings with approved cleaning | | |
| | detergent (Measurement base on floor | | |
| | area) (For Zone 4A & 4B) | | |
| | | | | Bldg Tc
| A540 | Wash oil stained floor/wall with | m2 | 0.40 | A540
| | 'Klenco Easy Clean' or other approved | | |
| | equivalent | | |
| | | | | Bldg Tc
| A541 | Wash down dust and stains on glass | m2 | 0.40 | A541
| | windows/panels/louvres/doors/shutters | | |
| | on both face including frames with | | |
| | approved detergent. | | |
| | | | |
| A542 | Remove existing vinyl/laminate floor | m2 | 1.20 | A542
| | tiles/sheets/carpets including all | | |
| | adhesive stain if any. | | |
| | | | |
| | SANITARY | | |
| | | | | Bldg Tc
| B001 | 400mm wide x 100mm thick concrete grade | m | 8.30 | B001
| | 20 bed under 100mm diameter drain pipes | | |
| | including haunching up sides of pipes to | | |
| | not less than half diameter of the pipes | | |
| | in similar concrete and necessary | | |
| | formwork. ( Drain pipes measured | | |
| | separately). | | |
| | | | |
| B002 | Extra over item (B001) for concrete | m | 4.10 | B002
| | grade 20 surround minimum 150mm thick. | | |
| | | | |
| B003 | 450mm wide x 100mm thick concrete grade | m | 8.80 | B003
| | 20 bed under 150mm diameter drain pipes | | |
| | including haunching up sides of pipes to | | |
| | not less than half diameter of the pipes | | |
| | in similar concrete and necessary | | |
| | formwork. (Drain pipes measured | | |
| | separately). | | |

PAGE 49 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| B004 | Extra over item (B003) for concrete | m | 6.70 | B004
| | grade 20 surround minimum 150mm thick. | | |
| | | | |
| | * Ductile iron cement lined (BS 4772) | | |
| | heavy duty water pipes including | | |
| | necessary accessories and flexible joints | | |
| | all in replacement laid in trench | | |
| | (Trench and concrete bed measured | | |
| | separately) *(B005 B006) | | |
| | | | |
| B005 | 80mm diameter | m | 32.90 | B005
| | | | |
| B006 | 100mm diameter | m | 33.60 | B006
| | | | |
| | * Heavy grade coated cast iron drain pipe | | |
| | including necessary accessories and | | |
| | flexible joints all in replacement laid | | |
| | in trench. (Trench and concrete bed | | |
| | measured separately) *(B007 B010) | | |
| | | | |
| B007 | 100mm diameter | m | 31.20 | B007
| | | | |
| B008 | Extra over item (B007) for duck-foot | no | 43.05 | B008
| | bend. | | |
| | | | |
| B009 | 150mm diameter | m | 48.70 | B009
| | | | |
| B010 | Extra over item (B009) for duck-foot | no | 74.90 | B010
| | bend. | | |
| | | | |
| B011 | 100mm diameter cast iron heavy duty | no | 44.30 | B011
| | union socket for underground pipe. | | |
| | | | |
| B012 | 100mm diameter cast iron heavy duty | no | 48.50 | B012
| | duck foot bend including breaking up | | |
| | concrete floor, excavation, and make | | |
| | good work disturbed. | | |
| | | | |
| | * Salt-glazed stoneware drain pipe in | | |
| | flexible joint including laying on | | |
| | concrete bed in trench in replacement | | |
| | (Trench and concrete bed measured | | |
| | separately) *(B013 B016) | | |
| | | | |
| B013 | 100mm diameter | m | 8.20 | B013
| | | | |
| B014 | Extra over item (B013) for bend | no | 2.85 | B014
| | | | |
| B015 | 150mm diameter | m | 13.55 | B015
| | | | |
| B016 | Extra over item (B015) for bends | no | 4.10 | B016
| | | | |

PAGE 50 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| B017 | 225mm x 450mm cast iron purpose made | no | 185.10 | B017
| | street gulley with 100mm outlet, | | |
| | including connection, all necessary | | |
| | excavation and concrete surround | | |
| | (in replacement). | | |
| | | | |
| B018 | Concrete Grade 20 in bottom of | m3 | 157.80 | B018
| | inspection chamber including necessary | | |
| | formworks and B7 fabric reinforcement | | |
| | | | |
| B019 | 225mm thick (average) concrete grade 20 | m2 | 129.50 | B019
| | benching and haunching to bottom of | | |
| | manholes finished with 13mm thick | | |
| | cement mortar (1:1) rendering, the whole | | |
| | finished off at a gradient of about one | | |
| | in six trowelled smooth with coves to | | |
| | 25mm radius at walls and rounded edges | | |
| | next channels including working | | |
| | carefully to edge of channels. (Channels | | |
| | measured separately) | | |
| | | | |
| B020 | 150mm thick concrete grade 20 top slab | m2 | 42.55 | B020
| | including formwork, B7 fabric | | |
| | reinforcement and forming opening for | | |
| | frames. (No deduction for opening) | | |
| | | | |
| B021 | 100mm diameter half round salt-glazed | m | 7.15 | B021
| | stoneware straight or curve branch | | |
| | channels including bedding and jointing | | |
| | in cement mortar (1:1). | | |
| | | | |
| B022 | 150mm diameter half round salt-glazed | m | 9.60 | B022
| | stoneware straight or curve main channel | | |
| | including bedding and jointing in cement | | |
| | mortar (1:1). | | |
| | | | |
| B023 | 100 - 150mm diameter half round | no | 12.80 | B023
| | salt-glazed stoneware taper piece | | |
| | including bedding and jointing in cement | | |
| | mortar (1:1) | | |
| | | | |
| B024 | 225mm thick brick works in manhole in | m2 | 36.35 | B024
| | cement mortar (1:3). | | |
| | | | |
| B025 | 13mm thick cement and sand (1:3) | m2 | 4.00 | B025
| | rendering to internal surfaces of | | |
| | manhole. | | |
| | | | |
| B026 | Supply and apply Granolithic concrete | m3 | 86.20 | B026
| | (1:1:1) to bottom slab in inspection | | |
| | chamber | | |
| | | | |

PAGE 51 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| B027 | 32kg light duty cast iron inspection | no | 36.10 | B027
| | chamber cover and frame including | | |
| | setting frame in cement mortar and | | |
| | sealing cover in grease and fine sand. | | |
| | | | |
| B028 | 32kg light duty cast iron inspection | no | 45.40 | B028
| | chamber cover and frame in | | |
| | replacement including cutting and | | |
| | removing old frame and making | | |
| | good in cement mortar. | | |
| | | | |
| B029 | 52kg heavy duty cast iron inspection | no | 54.40 | B029
| | chamber cover in replacement | | |
| | (excluding frame). | | |
| | | | |
| B030 | 790(L)x260(B)x 70(H)mm G30 reinforced | no | 70.05 | B030
| | concrete cover with 2 Nos galvanised R10 | | |
| | rings for grease interceptor. | | |
| | | | |
| B031 | 2100mm diameter aluminium chequered | no | 821.10 | B031
| | plate covers including frame according | | |
| | to drawing. | | |
| | | | |
| B032 | Raising or lowering of inspection | no | 20.40 | B032
| | chamber or sump cover and frame to match | | |
| | new levels using back existing cover | | |
| | and frame including making good all | | |
| | disturbed area. | | |
| | | | |
| B033 | 600 x 450mm recessed type cast iron | no | 49.05 | B033
| | inspection chamber cover and frame in | | |
| | replacement including removing old frame | | |
| | and making good work disturbed. | | |
| | | | |
| B034 | 700mm diameter Steel Silt Trap Drum | no | 338.10 | B034
| | of one metre in depth. | | |
| | | | |
| B035 | Supply and place grease trap | no | 528.50 | B035
| | interceptor in inspection chamber | | |
| | | | |
| B036 | 150mm diameter salt-glazed stoneware | no | 44.95 | B036
| | gulley complete with grating, 100mm | | |
| | diameter outgo and concrete surround of | | |
| | minimum 100mm thick including hacking | | |
| | existing damaged gulley and jointing to | | |
| | existing pipes. | | |
| | | | |
| B037 | Cast iron deep seal floor trap complete | no | 45.70 | B037
| | with hinged grating, cast iron hopper, | | |
| | and with vertical side or back inlets | | |
| | and 75mm diameter outgo pipe | | |
| | including hacking damaged trap and | | |
| | jointing to existing pipe. | | |

PAGE 52 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| B038 | 150mm diameter cast iron hopper | no | 27.70 | B038
| | connecting piece not exceeding 300mm | | |
| | long including hacking existing hopper | | |
| | and all necessary jointing. | | |
| | | | |
| B039 | 100mm diameter cast iron floor trap or | no | 44.95 | B039
| | floor waste with hinged grating, hopper | | |
| | and 75mm outgo and concrete surround | | |
| | (at ground floor slab) including hacking | | |
| | to remove existing damaged trap/waste | | |
| | and jointing to pipe. | | |
| | | | |
| B040 | 150mm diameter cast iron floor trap | no | 52.70 | B040
| | with hinged grating, hopper and 100mm | | |
| | diameter outgo and concrete surround (at | | |
| | ground floor slab) including hacking to | | |
| | remove existing damaged trap and | | |
| | jointing to pipe. | | |
| | | | |
| B041 | 100mm diameter cast iron 'S' trap | no | 37.70 | B041
| | (above ground level) | | |
| | | | |
| B042 | 150 x 150mm perforated/non-perforated | no | 11.75 | B042
| | galvanised steel hinged grating. | | |
| | | | |
| B043 | 100mm diameter copper grating with | no | 7.15 | B043
| | chrome finished and slit openings laid | | |
| | on cement mortar including necessary | | |
| | hacking. | | |
| | | | |
| B044 | 150 x 150mm non-perforated plastic | no | 4.00 | B044
| | gully gratings. | | |
| | | | |
| B045 | Nylon mosquito netting to grating | no | 1.15 | B045
| | of gully trap. | | |
| | | | |
| B046 | Stainless steel mosquito netting at | m2 | 30.25 | B046
| | sump pump | | |
| | | | |
| | * Plastic gratings including embedding in | | |
| | Cement mortar *(B047 B050) | | |
| | | | |
| B047 | 50mm diameter | no | 2.85 | B047
| | | | |
| B048 | 75mm diameter | no | 2.95 | B048
| | | | |
| B049 | 100mm diameter | no. | 3.40 | B049
| | | | |
| B050 | 150mm diameter | no. | 4.85 | B050
| | | | |

PAGE 53 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| B051 | 150mm diameter plastic hinged grating | no. | 3.45 | B051
| | for floor trap including setting in | | |
| | concrete/cement mortar (1:3) | | |
| | | | |
| B052 | 150mm plastic hinged grating with 100mm | no. | 3.45 | B052
| | diameter collar including embedding in | | |
| | cement mortar (1:3) | | |
| | | | |
| | * Galvanised steel spherical dome-shaped | | |
| | grating 2.5mm thick to rain water down | | |
| | pipe including hacking and setting with | | |
| | cement mortar *(B053 B054) | | |
| | | | |
| B053 | 75mm diameter | no. | 4.20 | B053
| | | | |
| B054 | 100mm diameter | no. | 4.20 | B054
| | | | |
| B055 | 100mm diameter vertical cast iron | no. | 6.60 | B055
| | grating with 115mm outgo for rain water | | |
| | down pipe including hacking and setting | | |
| | in cement mortar | | |
| | | | |
| B056 | 150mm diameter cast iron dome grating | no. | 9.90 | B056
| | including embedding in cement mortar | | |
| | | | |
| B057 | 100mm diameter ductile iron "Y" | no. | 114.35 | B057
| | junction including flanges and fixing | | |
| | accessories | | |
| | | | |
| B058 | 80mm diameter cast iron "Y" strainer | no | 267.75 | B058
| | ("Venn KY 6" or other approved | | |
| | equivalent) complete with fixing | | |
| | accessories | | |
| | | | |
| B059 | Steel bolt for cast iron inspection eye | no | 0.85 | B059
| | covers | | |
| | | | |
| B060 | Mild steel hanging brackets to pipes | no | 4.00 | B060
| | including making good all work disturbed. | | |
| | | | |
| | * Cast iron brackets to pipes including | | |
| | making good all work disturbed. | | |
| | *(B061 B062) | | |
| | | | |
| B061 | Not exceeding 100mm diameter | no. | 3.90 | B061
| | | | |
| B062 | Exceeding 100mm diameter | no. | 5.40 | B062
| | | | |

PAGE 54 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| | * Cast iron cleaning eye cover including | | |
| | all necessary bolts etc to pipes, bends, | | |
| | etc *(B063 B066) | | |
| | | | |
| B063 | 50mm diameter | no. | 2.85 | B063
| | | | |
| B064 | 75mm diameter | no. | 3.05 | B064
| | | | |
| B065 | 100mm diameter | no. | 3.35 | B065
| | | | |
| B066 | 150mm diameter | no. | 3.70 | B066
| | | | |
| B067 | Sealing up sand holes in cast iron | no. | 2.10 | B067
| | pipes with metallic epoxy resin as per | | |
| | manufacturer's instruction | | |
| | | | |
| | * UPVC(AE) pipes for rainwater, vent, | | |
| | waste and soil pipes including provision | | |
| | of new shackle clips/mild steel brackets | | |
| | where necessary and hacking of holes | | |
| | through walls or slabs and make good all | | |
| | work disturbed on completion. (Fittings | | |
| | measured separately). *(B068 B073) | | |
| | | | |
| B068 | 32mm diameter | m | 3.15 | B068
| | | | |
| B069 | 40mm diameter | m | 4.30 | B069
| | | | |
| B070 | 50mm diameter | m | 6.70 | B070
| | | | |
| B071 | 80mm diameter | m | 8.20 | B071
| | | | |
| B072 | 100mm diameter | m | 9.05 | B072
| | | | |
| B073 | 150mm diameter | m | 11.90 | B073
| | | | |
| B074 | 250mm dia UPVC rainwater downpipe | m | 21.40 | B074
| | including sockets and fixing accessories | | |
| | in trench(Concrete bed and haunching | | |
| | and elbows and 'T' junctions measured | | |
| | separately) | | |
| | | | |
| | * UPVC (AE) SS 272 fittings including | | |
| | all jointing and fixing accessories | | |
| | *(B075 B118) | | |
| | | | |
| B075 | 32mm diameter sweep junction plain | no. | 2.00 | B075
| | | | |
| B076 | 40mm diameter sweep junction plain | no. | 2.20 | B076
| | | | |
| B077 | 50mm diameter sweep junction plain | no. | 2.30 | B077
| | | | |

PAGE 55 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| B078 | 80mm diameter sweep junction plain | no. | 4.30 | B078
| | | | |
| B079 | 100mm diameter sweep junction plain | no. | 4.10 | B079
| | | | |
| B080 | 150mm diameter sweep junction plain | no. | 15.65 | B080
| | | | |
| B081 | 200 x 200 x 200mm diameter 'T' | no. | 65.00 | B081
| | junction | | |
| | | | |
| B082 | 200 x 150 x 200mm diameter 'T' | no. | 44.40 | B082
| | junction | | |
| | | | |
| B083 | 80 to 50mm diameter single reducing | no. | 4.85 | B083
| | junction | | |
| | | | |
| B084 | 100 to 50mm diameter single reducing | no. | 5.05 | B084
| | junction | | |
| | | | |
| B085 | 100 to 80mm diameter single reducing | no. | 4.40 | B085
| | junction | | |
| | | | |
| B086 | 150 to 100mm diameter single reducing | no. | 5.60 | B086
| | junction | | |
| | | | |
| B087 | 200 to 150mm diameter single reducing | no. | 30.15 | B087
| | junction | | |
| | | | |
| B088 | 100 to 50mm diameter boss connector | no. | 3.70 | B088
| | | | |
| B089 | 100 to 80mm diameter boss connector | no. | 3.70 | B089
| | | | |
| B090 | 80mm diameter socket (Screw-on type) | no. | 3.15 | B090
| | | | |
| B091 | 100mm diameter socket (Screw-on type) | no. | 4.20 | B091
| | | | |
| B092 | 150mm diameter socket (Screw-on type) | no. | 5.35 | B092
| | | | |
| B093 | 32mm diameter plain coupling | no. | 1.90 | B093
| | | | |
| B094 | 40mm diameter plain coupling | no. | 2.00 | B094
| | | | |
| B095 | 50mm diameter plain coupling | no. | 2.10 | B095
| | | | |
| B096 | 80mm diameter plain coupling | no. | 2.95 | B096
| | | | |
| B097 | 100mm diameter plain coupling | no. | 3.05 | B097
| | | | |
| B098 | 150mm diameter plain coupling | no. | 4.85 | B098
| | | | |
| B099 | 32mm diameter Bend (any Angles)/Elbow | no. | 1.80 | B099
| | plain with inspection opening | | |
| | | | |

PAGE 56 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| B100 | 40mm diameter Bend (any Angles)/Elbow | no. | 1.90 | B100
| | plain with inspection opening | | |
| | | | |
| B101 | 50mm diameter Bend (any Angles)/Elbow | no. | 1.90 | B101
| | plain with inspection opening | | |
| | | | |
| B102 | 80mm diameter Bend (any Angles)/Elbow | no. | 3.60 | B102
| | plain with inspection opening | | |
| | | | |
| B103 | 100mm diameter Bend (any Angles)/Elbow | no. | 3.40 | B103
| | plain with inspection opening | | |
| | | | |
| B104 | 150mm diameter Bend (any Angles)/Elbow | no. | 11.35 | B104
| | plain with inspection opening | | |
| | | | |
| B105 | 150 to 100mm diameter level invert | no. | 5.60 | B105
| | reducers | | |
| | | | |
| B106 | 100 to 80mm diameter level invert | no. | 4.40 | B106
| | reducers | | |
| | | | |
| B107 | 100 to 50mm diameter level invert | no. | 5.05 | B107
| | reducers | | |
| | | | |
| B108 | 100 to 80mm diameter reducing elbow | no. | 6.40 | B108
| | with inspection opening | | |
| | | | |
| B109 | 100 x 100 x 80mm tee | no. | 8.30 | B109
| | | | |
| B110 | 150 x 150 x 100mm tee | no. | 7.05 | B110
| | | | |
| B111 | 100mm tee | no. | 4.20 | B111
| | | | |
| B112 | 100mm cross tee | no. | 7.70 | B112
| | | | |
| B113 | 80mm female/female adaptor | no. | 4.85 | B113
| | | | |
| B114 | 100mm female/female adaptor | no. | 5.05 | B114
| | | | |
| B115 | 150mm female/female adaptor | no. | 5.80 | B115
| | | | |
| B116 | 80mm female/female spigot adaptor | no. | 4.40 | B116
| | | | |
| B117 | 100mm female/female spigot adaptor | no. | 7.70 | B117
| | | | |
| B118 | 150mm female/female spigot adaptor | no. | 11.45 | B118
| | | | |

PAGE 57 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| | * Straight connector (SS213) with rubber | | |
| | ring including application of approved | | |
| | silicone bonding agent to joints: | | |
| | *(B119 B125) | | |
| | | | |
| B119 | 50mm diameter (100mm length) | no | 17.65 | B119
| | | | |
| B120 | 80mm diameter (100mm length) | no | 19.00 | B120
| | | | |
| B121 | 100mm diameter (100mm length) | no | 20.40 | B121
| | | | |
| B122 | 125mm diameter (100mm length) | no | 26.70 | B122
| | | | |
| B123 | 150mm diameter (100mm length) | no | 28.90 | B123
| | | | |
| B124 | 80mm diameter (>100mm length) | no | 25.60 | B124
| | | | |
| B125 | 100mm diameter (>100mm length) | no | 28.25 | B125
| | | | |
| | * UPVC (AE) fittings including all | | |
| | jointing and fixing accessories | | |
| | *(B126 B144) | | |
| | | | |
| B126 | 32mm diameter 'S' trap | no. | 3.90 | B126
| | | | |
| B127 | 32mm diameter 'P' trap | no. | 3.90 | B127
| | | | |
| B128 | 40mm diameter 'S' trap | no. | 5.25 | B128
| | | | |
| B129 | 40mm diameter 'P' trap | no. | 5.25 | B129
| | | | |
| B130 | 100mm diameter floor/gulley trap | no | 7.70 | B130
| | | | |
| B131 | 100mm diameter 'S' Trap (floor waste trap | no | 9.25 | B131
| | including hopper and grating) | | |
| | | | |
| B132 | 100mm diameter down spout | no | 15.25 | B132
| | | | |
| B133 | 150mm diameter down spout | no | 17.85 | B133
| | | | |
| B134 | 200mm diameter down spout | no | 34.55 | B134
| | | | |
| B135 | 100mm diameter UPVC Pan collar | no | 5.80 | B135
| | | | |
| B136 | 50mm diameter service yard outlet | no | 5.05 | B136
| | | | |
| B137 | 150 x 150 UPVC floor trap grating | no | 3.25 | B137
| | | | |
| B138 | Plastic downspout outlet fixed to 80mm | no. | 12.50 | B138
| | diameter UPVC pipe in replacement | | |
| | | | |
| B139 | 80mm diameter testing openings (F & F) | no. | 7.80 | B139
| | | | |

PAGE 58 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| B140 | 100mm diameter testing openings (F & F) | no. | 6.40 | B140
| | | | |
| B141 | 150mm diameter testing openings (F & F) | no. | 11.65 | B141
| | | | |
| B142 | 80mm diameter cleaning eye cover | no. | 5.45 | B142
| | | | |
| B143 | 100mm diameter cleaning eye cover | no. | 5.45 | B143
| | | | |
| B144 | 150mm diameter cleaning eye cover | no. | 7.90 | B144
| | | | |
| | * UPVC (AW) water supply pipes | | |
| | including provision of new shackle | | |
| | clip/mild steel brackets where | | |
| | necessary and hacking of the hole | | |
| | through wall or slabs and making good | | |
| | all work disturbed on completion | | |
| | (Fittings measured separately) | | |
| | *(B145 B156) | | |
| | | | |
| B145 | 15mm diameter | m | 2.85 | B145
| | | | |
| B146 | 20mm diameter | m | 3.05 | B146
| | | | |
| B147 | 25mm diameter | m | 3.25 | B147
| | | | |
| B148 | 28mm diameter | m | 3.35 | B148
| | | | |
| B149 | 32mm diameter | m | 3.60 | B149
| | | | |
| B150 | 40mm diameter | m | 4.00 | B150
| | | | |
| B151 | 50mm diameter | m | 6.20 | B151
| | | | |
| B152 | 65mm diameter | m | 7.35 | B152
| | | | |
| B153 | 75mm diameter | m | 9.80 | B153
| | | | |
| B154 | 100mm diameter | m | 12.50 | B154
| | | | |
| B155 | 150mm diameter | m | 21.40 | B155
| | | | |
| B156 | 150mm diameter Half Round Pipe | m | 9.90 | B156
| | | | |
| | * UPVC (AW) fittings including jointing | | |
| | and make good all work disturbed | | |
| | on completion *(B157 B232) | | |
| | | | |
| B157 | 15mm diameter Tee | no | 1.90 | B157
| | | | |
| B158 | 20mm diameter Tee | no | 1.90 | B158
| | | | |

PAGE 59 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| B159 | 25mm diameter Tee | no | 2.10 | B159
| | | | |
| B160 | 32mm diameter Tee | no | 3.50 | B160
| | | | |
| B161 | 40mm diameter Tee | no | 3.50 | B161
| | | | |
| B162 | 50mm diameter Tee | no | 4.30 | B162
| | | | |
| B163 | 80mm diameter Tee | no | 7.80 | B163
| | | | |
| B164 | 20 x 15 x 20mm diameter Reducing Tee | no | 1.80 | B164
| | | | |
| B165 | 25 x 15 x 25mm diameter Reducing Tee | no | 1.90 | B165
| | | | |
| B166 | 40 x 15 x 40mm diameter Reducing Tee | no | 5.45 | B166
| | | | |
| B167 | 40 x 25 x 40mm diameter Reducing Tee | no | 5.45 | B167
| | | | |
| B168 | 50 x 40 x 50mm diameter Reducing Tee | no | 7.90 | B168
| | | | |
| B169 | 65 x 20 x 65mm diameter Reducing Tee | no | 17.10 | B169
| | | | |
| B170 | 80 x 50 x 80mm diameter Reducing Tee | no | 21.40 | B170
| | | | |
| B171 | 15mm diameter Connector or Socket | no | 1.60 | B171
| | | | |
| B172 | 20mm diameter Connector or Socket | no | 1.70 | B172
| | | | |
| B173 | 25mm diameter Connector or Socket | no | 1.80 | B173
| | | | |
| B174 | 32mm diameter Connector or Socket | no | 2.85 | B174
| | | | |
| B175 | 40mm diameter Connector or Socket | no | 3.35 | B175
| | | | |
| B176 | 50mm diameter Connector or Socket | no | 4.20 | B176
| | | | |
| B177 | 65mm diameter Connector or Socket | no | 5.55 | B177
| | | | |
| B178 | 80mm diameter Connector or Socket | no | 10.90 | B178
| | | | |
| B179 | 20mm to 15mm diameter Reducer | no | 1.70 | B179
| | | | |
| B180 | 25mm to 15mm diameter Reducer | no | 1.80 | B180
| | | | |
| B181 | 25mm to 20mm diameter Reducer | no | 1.80 | B181
| | | | |
| B182 | 32mm to 25mm diameter Reducer | no | 2.95 | B182
| | | | |
| B183 | 40mm to 32mm diameter Reducer | no | 3.60 | B183
| | | | |
| B184 | 50mm to 25mm diameter Reducer | no | 4.20 | B184
| | | | |

PAGE 60 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| B185 | 50mm to 40mm diameter Reducer | no | 4.75 | B185
| | | | |
| B186 | 80mm to 50mm diameter Reducer | no | 14.20 | B186
| | | | |
| B187 | 15mm diameter Bend (any Angles)/Elbow | no | 1.70 | B187
| | | | |
| B188 | 20mm diameter Bend (any Angles)/Elbow | no | 1.80 | B188
| | | | |
| B189 | 25mm diameter Bend (any Angles)/Elbow | no | 1.80 | B189
| | | | |
| B190 | 32mm diameter Bend (any Angles)/Elbow | no | 3.05 | B190
| | | | |
| B191 | 40mm diameter Bend (any Angles)/Elbow | no | 4.30 | B191
| | | | |
| B192 | 50mm diameter Bend (any Angles)/Elbow | no | 6.20 | B192
| | | | |
| B193 | 80mm diameter Bend (any Angles)/Elbow | no | 18.20 | B193
| | | | |
| B194 | 20mm - 15mm diameter Reducing Elbow | no | 1.80 | B194
| | | | |
| B195 | 25mm - 15mm diameter reducing Elbow | no | 1.80 | B195
| | | | |
| B196 | 15mm diameter Valve Socket | no | 1.60 | B196
| | | | |
| B197 | 20mm diameter Valve Socket | no | 1.60 | B197
| | | | |
| B198 | 25mm diameter Valve Socket | no | 1.70 | B198
| | | | |
| B199 | 32mm diameter Valve Socket | no | 3.15 | B199
| | | | |
| B200 | 40mm diameter Valve Socket | no | 3.40 | B200
| | | | |
| B201 | 50mm diameter Valve Socket | no | 4.00 | B201
| | | | |
| B202 | 65mm diameter Valve Socket | no | 10.00 | B202
| | | | |
| B203 | 80mm diameter Valve Socket | no | 11.55 | B203
| | | | |
| B204 | 15mm diameter Faucet Socket | no | 1.90 | B204
| | | | |
| B205 | 20mm diameter Faucet Socket | no | 2.20 | B205
| | | | |
| B206 | 25mm diameter Faucet Socket | no | 2.50 | B206
| | | | |
| B207 | 32mm diameter Faucet Socket | no | 3.40 | B207
| | | | |
| B208 | 40mm diameter Faucet Socket | no | 3.90 | B208
| | | | |
| B209 | 50mm diameter Faucet Socket | no | 4.75 | B209
| | | | |
| B210 | 15mm diameter Faucet Elbow | no | 2.20 | B210
| | | | |

PAGE 61 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| B211 | 15mm diameter Faucet Elbow with | no | 2.10 | B211
| | wall-plate | | |
| | | | |
| B212 | 20mm diameter Faucet Elbow | no | 2.65 | B212
| | | | |
| B213 | 25mm diameter Faucet Elbow | no | 3.25 | B213
| | | | |
| B214 | 40mm diameter Faucet Elbow | no | 4.30 | B214
| | | | |
| B215 | 15mm diameter End Cap | no | 1.90 | B215
| | | | |
| B216 | 20mm diameter End Cap | no | 2.10 | B216
| | | | |
| B217 | 25mm diameter End Cap | no | 2.30 | B217
| | | | |
| B218 | 32mm diameter End Cap | no | 3.05 | B218
| | | | |
| B219 | 40mm diameter End Cap | no | 3.15 | B219
| | | | |
| B220 | 50mm diameter End Cap | no | 3.55 | B220
| | | | |
| B221 | 65mm diameter End Cap | no | 3.55 | B221
| | | | |
| B222 | 80mm diameter End Cap | no | 4.60 | B222
| | | | |
| B223 | 100mm diameter end cap | no | 4.60 | B223
| | | | |
| B224 | 15mm diameter Single Joint | no | 1.80 | B224
| | | | |
| B225 | 20mm diameter Single Joint | no | 1.80 | B225
| | | | |
| B226 | 25mm diameter Single Joint | no | 1.90 | B226
| | | | |
| B227 | 32mm diameter Single Joint | no | 4.75 | B227
| | | | |
| B228 | 40mm diameter Single Joint | no | 5.05 | B228
| | | | |
| B229 | 50mm diameter Single Joint | no | 7.90 | B229
| | | | |
| B230 | 65mm diameter Single Joint | no | 7.90 | B230
| | | | |
| B231 | 80mm diameter Single Joint | no | 15.10 | B231
| | | | |
| B232 | 100mm diameter Single Joint | no | 23.00 | B232
| | | | |
| B233 | 16mm diameter PVC Shackle Clip | no | 0.85 | B233
| | | | |
| B234 | 22mm diameter PVC Shackle Clip | no | 0.85 | B234
| | | | |
| B235 | 28mm diameter PVC Shackle Clip | no | 0.85 | B235
| | | | |
| B236 | 35mm diameter GS Shackle Clip | no | 1.50 | B236
| | | | |

PAGE 62 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| B237 | 42mm diameter GS Shackle Clip | no | 1.50 | B237
| | | | |
| B238 | 54mm diameter GS Shackle Clip | no | 1.50 | B238
| | | | |
| B239 | Repair to leaking joints of UPVC pipe | job | 24.30 | B239
| | not exceeding 75mm diameter | | |
| | | | |
| B240 | Repair to leaking joints of UPVC pipe | job | 36.50 | B240
| | exceeding 75mm diameter and not | | |
| | exceeding 150mm diameter | | |
| | | | |
| | * UPVC lined galvanised steel water | | |
| | pipe including accessories, fittings, | | |
| | re-threading joints, shackes, clips, | | |
| | holderbats and cutting holes through | | |
| | walls | | |
| | *(B241 B249) | | |
| | | | |
| B241 | 13mm diameter | m | 9.15 | B241
| | | | |
| B242 | 20mm diameter | m | 10.00 | B242
| | | | |
| B243 | 25mm diameter | m | 9.15 | B243
| | | | |
| B244 | 32mm diameter | m | 10.20 | B244
| | | | |
| B245 | 40mm diameter | m | 14.50 | B245
| | | | |
| B246 | 50mm diameter | m | 15.65 | B246
| | | | |
| B247 | 65mm diameter | m | 17.95 | B247
| | | | |
| B248 | 75mm diameter | m | 24.05 | B248
| | | | |
| B249 | 100mm diameter | m | 37.15 | B249
| | | | |
| | * Galvanised steel holderbats, clips | | |
| | or shackle for GS water pipes including | | |
| | making good all work disturbed | | |
| | *(B250 B252) | | |
| | | | |
| B250 | Not exceeding 25mm diameter | no | 1.15 | B250
| | | | |
| B251 | Exceeding 25mm diameter but not exceeding | no | 1.90 | B251
| | 50mm diameter. | | |
| | | | |
| B252 | Exceeding 50mm diameter | no | 3.15 | B252
| | | | |

PAGE 63 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| B253 | Mild steel compression bracket | no | 17.75 | B253
| | comprising of two rings size 40mm wide, | | |
| | 5mm thick and 100mm diameter and two | | |
| | 10mm diameter threaded rods not | | |
| | exceeding 300mm long including painting. | | |
| | | | |
| B254 | 13mm diameter coupling washer | no | 0.85 | B254
| | | | |
| B255 | 20mm diameter coupling washer | no | 0.85 | B255
| | | | |
| B256 | 30mm diameter coupling washer | no | 0.85 | B256
| | | | |
| B257 | 40mm diameter coupling washer | no | 0.85 | B257
| | | | |
| B258 | 50mm diameter coupling washer | no | 0.95 | B258
| | | | |
| B259 | 75mm diameter coupling washer | no | 1.15 | B259
| | | | |
| B260 | 100mm diameter coupling washer | no | 1.25 | B260
| | | | |
| B261 | Galvanised flanged plate to 100mm | no | 13.25 | B261
| | diameter galvanised steel pipe. | | |
| | (gasket, bolts & nuts included). | | |
| | | | |
| | * Stainless steel pipes (BS 4127) | | |
| | including holderbats or clips and | | |
| | cutting of old pipes and making good on | | |
| | completion. (Fittings measured | | |
| | separately *(B262 B267) | | |
| | | | |
| B262 | 15mm diameter | m | 3.55 | B262
| | | | |
| B263 | 22mm diameter | m | 4.40 | B263
| | | | |
| B264 | 28mm diameter | m | 5.35 | B264
| | | | |
| B265 | 35mm diameter | m | 6.95 | B265
| | | | |
| B266 | 42mm diameter | m | 8.80 | B266
| | | | |
| B267 | 54mm diameter | m | 12.50 | B267
| | | | |
| B268 | 150mm diameter stainless steel | m | 69.20 | B268
| | waterpipe including holderbats or clips | | |
| | and cutting of old pipes (fittings | | |
| | measured separately) and making good on | | |
| | completion. | | |
| | | | |
| B269 | Repair to leaking joints of stainless | no | 24.40 | B269
| | steel/copper pipes including fixing | | |
| | accessories (regardless of diameter) | | |
| | | | |

PAGE 64 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| | * Copper pipes including holderbats, | | |
| | clips, fixing accessories and making | | |
| | good disturbed area | | |
| | *(B270 B274) | | |
| | | | |
| B270 | 15mm diameter (Fittings measured | m | 3.80 | B270
| | separately) | | |
| | | | |
| B271 | 22mm diameter (Fittings measured | m | 5.35 | B271
| | separately) | | |
| | | | |
| B272 | 28mm diameter (Fittings measured | m | 6.60 | B272
| | separately) | | |
| | | | |
| B273 | 54mm diameter (Inclusive of fittings) | m | 13.15 | B273
| | | | |
| B274 | 100mm diameter (Inclusive of fittings) | m | 35.50 | B274
| | | | |
| B275 | 15mm diameter copper piping 300mm long | no | 5.05 | B275
| | with connectors at both ends for | | |
| | fittings | | |
| | | | |
| | * Brass fittings for copper/stainless | | |
| | steel pipes *(B276 B340) | | |
| | | | |
| B276 | 15mm diameter Elbows | no | 3.35 | B276
| | | | |
| B277 | 22mm diameter Elbows | no | 4.40 | B277
| | | | |
| B278 | 28mm diameter Elbows | no | 5.15 | B278
| | | | |
| B279 | 35mm diameter Elbows | no | 8.40 | B279
| | | | |
| B280 | 42mm diameter Elbows | no | 11.75 | B280
| | | | |
| B281 | 54mm diameter Elbows | no | 18.60 | B281
| | | | |
| B282 | 15mm diameter Faucet Elbow fixed to | no | 3.15 | B282
| | wall for installation of tap | | |
| | | | |
| B283 | 15mm diameter Coupling/Union | no | 3.05 | B283
| | | | |
| B284 | 15mm diameter CFI coupling/Union | no | 3.05 | B284
| | | | |
| B285 | 22mm diameter Coupling/Union | no | 3.80 | B285
| | | | |
| B286 | 22mm diameter CFI coupling/Union | no | 3.35 | B286
| | | | |
| B287 | 28mm diameter Coupling/Union | no | 4.60 | B287
| | | | |
| B288 | 35mm diameter Coupling/Union | no | 7.15 | B288
| | | | |

PAGE 65 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| B289 | 42mm diameter Coupling/Union | no | 8.95 | B289
| | | | |
| B290 | 54mm diameter Coupling/Union | no | 12.20 | B290
| | | | |
| B291 | 15 x 22mm diameter CMI Coupling/Union | no | 3.35 | B291
| | | | |
| B292 | 28mm x 22mm diameter coupling | no | 4.40 | B292
| | | | |
| B293 | 42mm x 35mm diameter coupling | no | 9.45 | B293
| | | | |
| B294 | 42 x 28mm diameter coupling/union | no | 13.15 | B294
| | | | |
| B295 | 35 x 54mm diameter Union | no | 11.85 | B295
| | | | |
| B296 | 42 x 54mm diameter Union | no | 11.85 | B296
| | | | |
| B297 | 15 x 15 x 15mm diameter Tee | no | 3.70 | B297
| | | | |
| B298 | 15 x 22 x 15mm diameter Tee | no | 4.60 | B298
| | | | |
| B299 | 22 x 15 x 22mm diameter Tee | no | 4.60 | B299
| | | | |
| B300 | 22 x 22 x 15mm diameter Tee | no | 5.05 | B300
| | | | |
| B301 | 22 x 22 x 22mm diameter Tee | no | 4.75 | B301
| | | | |
| B302 | 28 x 15 x 28mm diameter Tee | no | 6.50 | B302
| | | | |
| B303 | 28 x 22 x 28mm diameter Tee | no | 6.50 | B303
| | | | |
| B304 | 28 x 28 x 15mm diameter Tee | no | 7.45 | B304
| | | | |
| B305 | 28 x 28 x 22mm diameter Tee | no | 7.45 | B305
| | | | |
| B306 | 28 x 28 x 28mm diameter Tee | no | 6.40 | B306
| | | | |
| B307 | 28 x 35 x 28mm diameter Tee | no | 15.00 | B307
| | | | |
| B308 | 35 x 15 x 35mm diameter Tee | no | 11.85 | B308
| | | | |
| B309 | 35 x 35 x 15mm diameter Tee | no | 13.85 | B309
| | | | |
| B310 | 35 x 35 x 22mm diameter Tee | no | 13.85 | B310
| | | | |
| B311 | 35 x 35 x 28mm diameter Tee | no | 13.85 | B311
| | | | |
| B312 | 42 x 22 x 42mm diameter Tee | no | 16.80 | B312
| | | | |
| B313 | 42 x 28 x 42mm diameter Tee | no | 16.80 | B313
| | | | |
| B314 | 42 x 42 x 15mm diameter Tee | no | 19.95 | B314
| | | | |

PAGE 66 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| B315 | 42mm x 42mm x 22mm tee | no | 19.95 | B315
| | | | |
| B316 | 42mm x 42mm x 28mm tee | no | 19.95 | B316
| | | | |
| B317 | 42mm x 42mm x 35mm tee | no | 19.95 | B317
| | | | |
| B318 | 42 x 42 x 42mm diameter Tee | no | 15.85 | B318
| | | | |
| B319 | 54 x 28 x 54mm diameter Tee | no | 25.50 | B319
| | | | |
| B320 | 54 x 35 x 54mm diameter Tee | no | 25.50 | B320
| | | | |
| B321 | 54 x 42 x 54mm diameter Tee | no | 25.50 | B321
| | | | |
| B322 | 54mm x 54mm x 22mm tee | no | 30.45 | B322
| | | | |
| B323 | 54mm x 54mm x 28mm tee | no | 30.45 | B323
| | | | |
| B324 | 54 x 54 x 54mm diameter Tee | no | 27.20 | B324
| | | | |
| B325 | 22 to 15mm diameter Reducing Elbows | no | 4.10 | B325
| | | | |
| B326 | 28 to 15mm diameter Reducing Elbows | no | 5.55 | B326
| | | | |
| B327 | 28 to 22mm diameter Reducing Elbows | no | 5.55 | B327
| | | | |
| B328 | 35 to 15mm diameter Reducing Elbows | no | 10.10 | B328
| | | | |
| B329 | 35 to 22mm diameter Reducing Elbows | no | 10.10 | B329
| | | | |
| B330 | 35 to 28mm diameter Reducing Elbows | no | 10.10 | B330
| | | | |
| B331 | 42 to 28mm diameter Reducing Elbows | no | 15.25 | B331
| | | | |
| B332 | 42 to 35mm diameter Reducing Elbows | no | 17.95 | B332
| | | | |
| B333 | 54 to 15mm diameter Reducing Elbows | no | 22.70 | B333
| | | | |
| B334 | 54 to 28mm diameter Reducing Elbows | no | 22.70 | B334
| | | | |
| B335 | 54 to 35mm diameter Reducing Elbows | no | 22.70 | B335
| | | | |
| B336 | 54 to 42mm diameter Reducing Elbows | no | 22.70 | B336
| | | | |
| B337 | 42mm diameter brass stop end | no | 13.65 | B337
| | | | |
| B338 | 54mm diameter brass stop end | no | 16.90 | B338
| | | | |
| B339 | 13mm diameter brass nipple | no | 3.05 | B339
| | | | |
| B340 | 54mm diameter brass nipple | no | 7.25 | B340
| | | | |

PAGE 67 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| | * Ductile iron cement lined water pipes | | |
| | BS 4772:1988 with spigot and socket | | |
| | joints/flanged joints and all necessary | | |
| | fixing accessories and brackets/supports | | |
| | including hacking holes through floors, | | |
| | walls, or roofs and make good disturbed | | |
| | area *(B341 B378) | | |
| | | | |
| B341 | 80mm diameter water pipes | m | 29.40 | B341
| | | | |
| B342 | 80mm diameter bend | no | 24.05 | B342
| | | | |
| B343 | 80mm diameter tee | no | 33.70 | B343
| | | | |
| B344 | 80mm diameter collar | no | 31.80 | B344
| | | | |
| B345 | 80 to 40mm diameter reducer | no | 21.40 | B345
| | | | |
| B346 | 80 to 50mm diameter reducer | no | 20.35 | B346
| | | | |
| B347 | 80mm diameter socket and flanged | no | 37.15 | B347
| | connector | | |
| | | | |
| B348 | 80mm diameter blank flange | no | 10.50 | B348
| | | | |
| B349 | 100mm diameter water pipe | m | 30.15 | B349
| | | | |
| B350 | 100mm diameter tee | no | 38.35 | B350
| | | | |
| B351 | 100mm diameter collar | no | 53.45 | B351
| | | | |
| B352 | 100 to 80mm diameter reducer | no | 26.90 | B352
| | | | |
| B353 | 100mm diameter "duck" foot bend | no | 35.30 | B353
| | | | |
| B354 | 100mm diameter socket | no | 35.30 | B354
| | | | |
| B355 | 100mm groove coupling | no | 9.85 | B355
| | | | |
| B356 | 100mm diameter spigot | no | 26.90 | B356
| | | | |
| B357 | 100 x 50 x 50mm diameter tee | no | N.A | B357
| | | | |
| B358 | 100 x 100 x 100mm diameter tee | no | 31.70 | B358
| | | | |
| B359 | 100 x 50 x 100mm diameter tee | no | 31.70 | B359
| | | | |
| B360 | 150 x 100x 150mm diameter tee | no | 75.20 | B360
| | | | |
| B361 | 150 x 150 x 150mm diameter tee | no | 73.40 | B361
| | | | |

PAGE 68 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| B362 | 100mm diameter elbow/bend | no | 15.95 | B362
| | | | |
| B363 | 100mm x 90 degree groove bend | no | 15.95 | B363
| | | | |
| B364 | 100mm diameter blank flange | no | 11.75 | B364
| | | | |
| B365 | 100mm diameter lengthening | no | 29.30 | B365
| | piece not exceeding 300mm long | | |
| | | | |
| B366 | 100mm diameter lengthening piece | no | 48.60 | B366
| | exceeding 300mm but not exceeding | | |
| | 600mm long. | | |
| | | | |
| B367 | 100mm diameter lengthening piece | no | 59.45 | B367
| | exceeding 600mm but not exceeding | | |
| | 900mm long. | | |
| | | | |
| B368 | 215mm diameter flange washer for | no | 6.20 | B368
| | water main | | |
| | | | |
| B369 | 100mm dia x 300mm bend | no | 35.30 | B369
| | | | |
| B370 | 150mm diameter water pipe | m | 44.10 | B370
| | | | |
| B371 | 150mm diameter "duck foot" bend | no | 57.75 | B371
| | | | |
| B372 | 150mm diameter bend | no | 31.80 | B372
| | | | |
| B373 | 150 to 100mm diameter reducer | no | 37.15 | B373
| | | | |
| B374 | Supply, delivery and laying of 225mm | m | 73.20 | B374
| | diameter ductile iron pipe with cement | | |
| | lining. | | |
| | | | |
| B375 | Deduct from 100mm diameter water main | m | 1.90 | B375
| | for without cement lining. | | |
| | | | |
| B376 | Deduct from 150mm diameter water main | m | 5.55 | B376
| | for without cement lining | | |
| | | | |
| B377 | Deduct from 100mm diameter fitting for | m | 2.00 | B377
| | without cement lining | | |
| | | | |
| B378 | Deduct from 150mm diameter fitting for | m | 5.90 | B378
| | without cement lining | | |
| | | | |

PAGE 69 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| | * Heavy duty galvanised steel pipe to | | |
| | SS17 including accessories, re-threading | | |
| | all joints and providing additional | | |
| | holderbats and cutting holes through | | |
| | walls if necessary *(B379 B380) | | |
| | | | |
| B379 | 80mm diameter | m | 16.40 | B379
| | | | |
| B380 | 150mm diameter | m | 104.15 | B380
| | | | |
| | * Heavy duty galvanised steel fittings | | |
| | to SS17 including jointing accessories. | | |
| | *(B381 B387) | | |
| | | | |
| B381 | 80mm diameter elbow | no | 12.60 | B381
| | | | |
| B382 | 80mm x 15mm diameter tee | no | 17.35 | B382
| | | | |
| B383 | 80mm diameter socket | no | 8.95 | B383
| | | | |
| B384 | 150mm diameter bend/elbow | no | 69.95 | B384
| | | | |
| B385 | 150mm diameter tee | no | 81.40 | B385
| | | | |
| B386 | 150mm diameter collar clip | no | 7.90 | B386
| | | | |
| B387 | 15mm diameter G.I. Plug | no | 2.50 | B387
| | | | |
| | * Hubless epoxy coated cast iron pipe/ | | |
| | fittings including all fixing clips, | | |
| | accessories, shackles and brackets. | | |
| | *(B388 B398) | | |
| | | | |
| B388 | 100mm diameter pipe | m | 24.80 | B388
| | | | |
| B389 | 150mm diameter pipe | m | 36.55 | B389
| | | | |
| B390 | 100mm diameter tee | no | 24.70 | B390
| | | | |
| B391 | 100mm diameter 'S' trap | no | 41.05 | B391
| | | | |
| B392 | 100mm - 90mm diameter bend | no | 16.90 | B392
| | | | |
| B393 | 100mm - 45mm diameter bend | no | 16.70 | B393
| | | | |
| B394 | 100mm diameter Bend/Elbow (all angles) | no | 16.90 | B394
| | | | |
| B395 | 100mm diameter Joint's Clip | no | 5.90 | B395
| | | | |
| B396 | 150mm diameter Joint's Clip | no | 8.20 | B396
| | | | |
| B397 | 100mm diameter Access Opening | no | 59.00 | B397
| | | | |

PAGE 70 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| B398 | 150mm diameter Access Opening | no | 102.40 | B398
| | | | |
| | * Brass high pressure screw down | | |
| | stop-cocks/taps complying with BS75 | | |
| | including crutch handle and fixing | | |
| | accessories *(B399 B409) | | |
| | | | |
| B399 | 13mm diameter brass bib tap with | no | 13.95 | B399
| | 'Allen' key handle | | |
| | | | |
| B400 | 15mm diameter bib cock | no | 11.75 | B400
| | | | |
| B401 | 20mm diameter bib cock | no | 19.55 | B401
| | | | |
| B402 | 15mm diameter stop-cock | no | 11.75 | B402
| | | | |
| B403 | 20mm diameter stop-cock | no | 19.55 | B403
| | | | |
| B404 | 25mm diameter stop-cock | no | 33.50 | B404
| | | | |
| B405 | 32mm diameter stop-cock | no | 89.05 | B405
| | | | |
| B406 | 40mm diameter stop-cock | no | 110.80 | B406
| | | | |
| B407 | 50mm diameter stop-cock | no | 159.10 | B407
| | | | |
| B408 | 13mm diameter garden bib tap with | no | 8.10 | B408
| | spigot nozzle | | |
| | | | |
| B409 | 20mm diameter garden bib tap with | no | 25.00 | B409
| | spigot nozzle | | |
| | | | |
| | * Chromium plated high pressure brass | | |
| | screw down stop-cocks/taps including | | |
| | fixing accessories *(B410 B415) | | |
| | | | |
| B410 | 13mm diameter bib tap with 'Allen' key | no | 17.75 | B410
| | handle | | |
| | | | |
| B411 | 15mm dia bib tap "Penguin", "Mihedo MH" | no | 10.50 | B411
| | or approved equivalent with detached | | |
| | handle ('Allen' key handle) and hose | | |
| | union. | | |
| | | | |
| B412 | 15mm diameter bib tap "Bibo","Enola | no | 11.15 | B412
| | WY/e.2" or approved equivalent with | | |
| | hose union | | |
| | | | |
| B413 | 15mm diameter chrome plated bib tap | no | 11.55 | B413
| | with padlock locking device and water | | |
| | hose connector. | | |
| | | | |

PAGE 71 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| B414 | 20mm diameter bib cock | no | 19.95 | B414
| | | | |
| B415 | 13mm diameter stop-cock | no | 13.00 | B415
| | | | |
| B416 | Brass hose connector to tap. | no | 4.20 | B416
| | | | |
| B417 | 2-way outlet hydrant pillar including | no | 159.10 | B417
| | fixing accessories | | |
| | | | |
| | * Fixing accessories | | |
| | *(B418 B425) | | |
| | | | |
| B418 | Rubber washer for 13mm to 25mm diameter | no | 2.40 | B418
| | stopcock or bib cock or tap | | |
| | | | |
| B419 | Rubber washer for 30mm to 50mm diameter | no | 2.85 | B419
| | stopcock or bib cock or tap | | |
| | | | |
| B420 | Gland nut for 13mm diameter stop-cock/ | no | 2.40 | B420
| | bib cock | | |
| | | | |
| B421 | Gland nut for 20mm diameter | no | 2.50 | B421
| | stop-cock/bib cock | | |
| | | | |
| B422 | Gland nut for 25mm diameter | no | 2.65 | B422
| | stop-cock/bib cock | | |
| | | | |
| B423 | Gland nut for 32mm diameter | no | 2.85 | B423
| | stop-cock/bib cock | | |
| | | | |
| B424 | Gland nut for 40mm diameter | no | 2.85 | B424
| | stop-cock/bib cock | | |
| | | | |
| B425 | Gland nut for 50mm diameter | no | 3.25 | B425
| | stop-cock/bib cock | | |
| | | | |
| | * Valves(brass/bronze) to BS 5154 | | |
| | including washers, gaskets, bolts, nuts | | |
| | and wheel handle (if applicable) | | |
| | *(B426 B454) | | |
| | | | |
| B426 | 20mm diameter bronze gate valve | no | 9.65 | B426
| | | | |
| B427 | 25mm diameter bronze gate valve | no | 11.65 | B427
| | | | |
| B428 | 30mm diameter bronze gate valve | no | 16.10 | B428
| | | | |
| B429 | 40mm diameter bronze gate valve | no | 18.50 | B429
| | | | |
| B430 | 50mm diameter bronze gate valve | no | 27.70 | B430
| | | | |

PAGE 72 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| B431 | 75mm diameter bronze gate valve | no | 119.80 | B431
| | | | |
| B432 | 100mm diameter bronze gate valve | no | 177.75 | B432
| | | | |
| B433 | 50mm diameter brass gate valve | no | 30.15 | B433
| | | | |
| B434 | 80mm diameter brass gate valve | no | 113.80 | B434
| | | | |
| B435 | 100mm diameter brass gate valve | no | 123.50 | B435
| | | | |
| B436 | 80mm diameter cast iron sluice valve | no | 113.80 | B436
| | with flanged ends and wheel head | | |
| | | | |
| B437 | 100mm diameter cast iron sluice valve | no | 137.95 | B437
| | with flanged ends and wheel head | | |
| | | | |
| B438 | 150mm diameter cast iron sluice valve | no | 222.50 | B438
| | with flanged ends and wheel head | | |
| | | | |
| B439 | 25mm diameter check valve | no | 27.50 | B439
| | | | |
| B440 | 42mm diameter brass check valve for | no | 40.20 | B440
| | booster pump | | |
| | | | |
| B441 | 50mm diameter bronze spring loaded | no | 35.90 | B441
| | lift check valve. | | |
| | | | |
| B442 | 50mm diameter bronze check valve | no | 41.25 | B442
| | | | |
| B443 | 75mm diameter bronze check valve | no | 145.95 | B443
| | | | |
| B444 | 80mm diameter bronze check valve | no | 138.60 | B444
| | (swing type) | | |
| | | | |
| B445 | 40mm diameter spring-loaded brass check | no | 28.15 | B445
| | valve | | |
| | | | |
| B446 | 50mm diameter spring-loaded brass check | no | 26.45 | B446
| | valve | | |
| | | | |
| B447 | 80mm diameter spring-loaded brass check | no | 156.05 | B447
| | valve | | |
| | | | |
| B448 | 100mm diameter spring-loaded brass check | no | 228.50 | B448
| | valve | | |
| | | | |
| B449 | 40mm diameter brass ball valve | no | 39.05 | B449
| | | | |
| B450 | 150mm diameter spring loaded brass | no | 316.15 | B450
| | check valve | | |
| | | | |

PAGE 73 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| B451 | 22mm diameter mini ball valve | no | 6.95 | B451
| | | | |
| B452 | 42mm diameter pressure release valve | no | 91.45 | B452
| | | | |
| B453 | 65mm diameter brass landing valve | no | 84.20 | B453
| | | | |
| B454 | 50mm diameter bronze drain cock | no | 38.35 | B454
| | | | |
| B455 | 100mm diameter 'Victaulic VIC 300L' | no | 250.45 | B455
| | ductile iron butterfly valve with grooved | | |
| | ends and lever operated including | | |
| | fixing accessories. | | |
| | | | |
| | * Vitreous china wash hand basin complete | | |
| | with hanging brackets,waste discharge | | |
| | pipes, bottle trap and grating, | | |
| | vulcanite plug and chain *(B456 B459) | | |
| | | | |
| B456 | 'Potex 2006' vanity basin including | no | 59.45 | B456
| | fixing accessories | | |
| | | | | Updated
| B457 | 500 x 400mm (Johnson Suisse "Boston | no | 77.80 | B457
| | 500" or approved equivalent) | | |
| | | | |
| B458 | 560 x 425mm (Johnson Suisse "Rosslave" | no | 88.50 | B458
| | or approved equivalent) | | |
| | | | |
| B459 | 600 x 500mm (Johnson Suisse "Boston | no | 94.60 | B459
| | 600" or approved equivalent) | | |
| | | | |
| B460 | 900 x 500 x 150mm deep single bowl and | no | 107.85 | B460
| | single drainer stainless steel basin | | |
| | complete with hanging brackets,waste | | |
| | discharge pipes, bottle trap and | | |
| | grating, vulcanite plug & chain | | |
| | | | |
| | * Fitting and accessories to basin and | | |
| | sink *(B461 B471) | | |
| | | | |
| B461 | Cantilever bracket | no | 3.90 | B461
| | | | |
| B462 | Brass waste complete with cobweb | no | 6.20 | B462
| | grating and plug with chain | | |
| | | | |
| B463 | 32mm diameter PVC bottle trap | no | 3.55 | B463
| | | | |
| B464 | 38mm diameter PVC bottle trap | no | 3.55 | B464
| | | | |
| B465 | Waste pipe complete with necessary | no | 3.55 | B465
| | fittings | | |
| | | | |

PAGE 74 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| B466 | 13mm diameter spring loaded | no | 38.65 | B466
| | self-closing tap | | |
| | | | |
| B467 | 13mm diameter pillar tap (valve type) | no | 17.75 | B467
| | | | |
| B468 | Screw down pillar tap | no | 16.60 | B468
| | | | |
| B469 | Push button (spring type) pillar tap | no | 26.25 | B469
| | | | |
| B470 | Push button ( "Presto" delay action | no | 74.55 | B470
| | type) pillar tap | | |
| | | | |
| B471 | Sensor tap "Reliance AST.AC042" or | no | 304.00 | B471
| | approved equivalent with infrared | | |
| | sensor action | | |
| | | | |
| | * Sanitary fittings and accessories | | |
| | including hacking up/removal of | | |
| | existing damaged fittings/accessories | | |
| | and make good all work disturbed | | |
| | *(B472 B548) | | |
| | | | |
| B472 | 100mm diameter UPVC 'S' floor trap | no | 19.00 | B472
| | with hopper and vent with grating | | |
| | including jointing to waste pipe for | | |
| | upper/ground floor | | |
| | | | |
| B473 | 100mm diameter UPVC 'P' trap complete | no | 18.40 | B473
| | with hopper and vent with grating | | |
| | including jointing to waste pipe for | | |
| | upper/ground floor | | |
| | | | |
| | * Flushing valve / device c/w stop valve, | | |
| | check valve, vacuum breaker and | | |
| | associated standard accessories | | |
| | *(B474 B496) | | |
| | | | |
| B474 | Urinal manual operated, exposed type | no | 56.40 | B474
| | (Rigel FU102P or approved equivalent) | | |
| | | | |
| B475 | Urinal manual operated, concealed type | no | 110.80 | B475
| | (Rigel FU-108DP or approved equivalent) | | |
| | | | |
| B476 | Urinal Sensor operated, exposed type | no | 304.00 | B476
| | (Rigel AFS-201E or approved equivalent) | | |
| | | | |
| B477 | Urinal sensor concealed-box type c/w | no | 243.60 | B477
| | cam lock flush valve for canteen "Rigel | | |
| | AFS-201CLT" or approved equivalent | | |
| | | | |

PAGE 75 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| B478 | Micro switch 'Rigel' for sensor flush | no | 10.50 | B478
| | valve | | |
| | | | |
| B479 | Power supply unit 'Rigel' for sensor | no | 86.50 | B479
| | flush valve | | |
| | | | |
| B480 | SMT WC sensor eye 'Rigel' for sensor | no | 98.60 | B480
| | flush valve | | |
| | | | |
| B481 | Elbow for 'Rigel' sensor flush valve | no | 8.10 | B481
| | | | |
| B482 | Inlet spud 'Toto T52-S32R' flush valve | no | 35.70 | B482
| | including fixing accessories | | |
| | | | |
| B483 | Water closet manual operated exposed | no | 98.70 | B483
| | type (Rigel FC-102VP or approved | | |
| | equivalent) | | |
| | | | |
| B484 | Water closet manual operated concealed | no | 147.00 | B484
| | type (Rigel FC-104DP or approved | | |
| | equivalent) | | |
| | | | |
| B485 | Water closet Sensor operated, concealed | no | 364.35 | B485
| | type (Rigel AFS-101E or AFS-101CLS or | | |
| | approved equivalent) | | |
| | | | |
| B486 | Exposed water closet flush valve | no | 111.20 | B486
| | "Rigel FC-102VP" or approved equivalent | | |
| | with 204 x 408mm 'L' flush pipe, vacuum | | |
| | breaker and stop-valve for back inlet | | |
| | water closet | | |
| | | | |
| B487 | Exposed water closet flush valve | no | 110.55 | B487
| | "Rigel FC-102VP" or approved equivalent | | |
| | with 280mm long supply pipe, vacuum | | |
| | breaker and stop valve for top inlet | | |
| | water closet bowl | | |
| | | | |
| B488 | Exposed water closet water-saving flush | no | 111.10 | B488
| | valve "Rigel FC-102VP" or approved | | |
| | equivalent with 470 x 320mm long 'T' | | |
| | flush pipe, vacuum breaker and stop | | |
| | valve | | |
| | | | |
| B489 | Exposed water closet water-saving flush | no | 110.55 | B489
| | valve "Rigel FC-102VP" or approved | | |
| | equivalent with 280mm long flush pipe, | | |
| | vacuum breaker and stop valve | | |
| | | | |

PAGE 76 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| B490 | WC sensor concealed-box type flush | no | 460.95 | B490
| | valve with cam lock and manual | | |
| | over-riding for canteen "Rigel AFS | | |
| | 101-CLST" or other approved equivalent | | |
| | | | |
| B491 | Concealed water closet water-saving | no | 151.75 | B491
| | concealed flush valve "Rigel FC-104DP" | | |
| | or approved equivalent with flushing | | |
| | pipe and 32mm diameter elbow coupling | | |
| | | | |
| B492 | 'Rigel HYD' hydraulic actuator for | no | 32.15 | B492
| | flushing system. | | |
| | | | |
| B493 | 'Rigel' elbow 6mm tub 1/8m r 6mm tub | no | 8.00 | B493
| | m5 thread for flushing system. | | |
| | | | |
| B494 | 'Rigel' WC piston for version B for | no | 32.15 | B494
| | flushing system. | | |
| | | | |
| B495 | Battery pack to flushing sensor | no | 36.25 | B495
| | (Batteries measured separately). | | |
| | | | |
| B496 | 'Energizer No. L91' or other approved | no | 5.45 | B496
| | equivalent 'AA' size lithium battery for | | |
| | for flushing sensor. | | |
| | | | | Updated
| B497 | White vitreous China wall hung urinal | no | 157.10 | B497
| | bowl (Johnson Suisse Santana 320 or | | |
| | approved equivalent) | | |
| | | | |
| B498 | White glazed urinal slabs 600mm wide x | no | 257.45 | B498
| | 1050mm high including making good all | | |
| | works disturbed | | |
| | | | |
| B499 | White glazed urinal return end slab | no | 171.55 | B499
| | 1050mm high to match existing and | | |
| | including making good all works | | |
| | disturbed | | |
| | | | |
| B500 | 75mm diameter brass cobweb grating to | no | 14.60 | B500
| | urinal | | |
| | | | | Updated
| B501 | White earthenware squat w.c. pan only, | no | 88.80 | B501
| | complete with trap and with/without vent | | |
| | including making good tile surround to | | |
| | match if necessary and hacked up | | |
| | existing damage pan. | | |
| | | | |
| B502 | Porcelain enameled foottreads for squat | pair | 17.35 | B502
| | pan including hacking up existing and | | |
| | make good tile surround if necessary to | | |
| | match existing | | |
| | | | | Updated

PAGE 77 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| B503 | White earthenware pedestal w.c. pan | no | 84.00 | B503
| | "Saniton" or approved equivalent | | |
| | complete with trap with or | | |
| | without vent. | | |
| | | | |
| B504 | WC for Workshop "Saniton,Thunia ST2088, | no | 231.40 | B504
| | Daisy ST2199" or approved equivalent | | |
| | | | |
| B505 | White squatting WC for canteen | no | 105.75 | B505
| | "Saniton, Violet ST2133" or approved | | |
| | equivalent | | |
| | | | |
| B506 | Coloured squatting WC for canteen | no | 129.90 | B506
| | "Saniton, Violet ST2133" or approved | | |
| | equivalent | | |
| | | | | Updated
| B507 | White vitreous China pedestal w.c. | no | 185.20 | B507
| | suite valve type c/w flushing cistern | | |
| | close-coupled with pedestal water closet | | |
| | pan including seat, cover and approved | | |
| | fittings.(Potex or approved equivalent) | | |
| | | | |
| B508 | 3 1/2" expansion fixing screw 'Johnson | no | 7.35 | B508
| | Sussie Environ 3' for fixing cistern to | | |
| | pedestal. | | |
| | | | |
| B509 | PVC screw cap for vent of w.c. squat/ | no | 3.55 | B509
| | pedestal pan | | |
| | | | | Updated
| B510 | Plastic w.c. seat and cover (Heavy duty | no | 22.50 | B510
| | type) | | |
| | | | |
| B511 | Plastic pedestal w.c. seat | no | 8.10 | B511
| | | | | Bldg TC
| B512 | 9/4.5 litres dual action low level | no | 43.90 | B512
| | plastic cistern complete with plastic | | |
| | handle. | | |
| | | | | Bldg TC
| B513 | 9/4.5 litres dual action high level | no | 45.05 | B513
| | plastic cistern complete with nylon cord and | | |
| | plastic pull | | |
| | | | |
| B514 | Plastic cover to w.c. cistern | no | 7.05 | B514
| | | | |
| B515 | 75mm high cement surround at base of | no | 2.10 | B515
| | w.c. cistern flush-pipe and squat pan | | |
| | joint to cure leak | | |
| | | | |
| B516 | W.C. pedestal pan gasket | no | 4.50 | B516
| | | | |

PAGE 78 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| B517 | UPVC flush pipe not exceeding 2.0m long | no | 4.10 | B517
| | bent to high level cistern | | |
| | | | |
| B518 | UPVC flush pipe exceeding 2.0m but | no | 4.50 | B518
| | not exceeding 3.0m long bent to high | | |
| | level cistern | | |
| | | | |
| B519 | 40mm diameter PVC flush pipe to low | no | 5.65 | B519
| | level cistern | | |
| | | | |
| B520 | Plastic siphon unit to high/low level | no | 27.95 | B520
| | cistern | | |
| | | | |
| B521 | Cistern fitting "NOVA" excluding | no | 66.25 | B521
| | warning pipe and inlet valve | | |
| | | | |
| B522 | Rubber cone for joint between flush | no | 5.05 | B522
| | pipe and back inlet of w.c. pedestal pan | | |
| | | | |
| B523 | Rubber washer to w.c. cistern siphon | no | 3.25 | B523
| | plunger including dismantling and | | |
| | refixing unit | | |
| | | | |
| B524 | Galvanised siphon hook | no | 2.50 | B524
| | | | |
| B525 | Chrome Plated lever handle to low level | no | 8.10 | B525
| | w.c. cistern | | |
| | | | |
| B526 | Brass flush arm to high level cistern | no | 9.75 | B526
| | | | |
| B527 | Plastic flush arm to w.c. cistern | no | 3.05 | B527
| | | | |
| B528 | Plastic flush arm holder with nylon | no | 5.05 | B528
| | rope to w.c. cistern | | |
| | | | |
| B529 | Plastic nut for flush pipe to w.c. | no | 3.70 | B529
| | cistern outlet connection | | |
| | | | |
| B530 | Plastic ball-cock complete to w.c. | no | 7.45 | B530
| | cistern | | |
| | | | |
| B531 | 13mm diameter ball valve in w.c. | no | 4.95 | B531
| | cistern | | |
| | | | |
| B532 | 25mm diameter ball valve in w.c. | no | 10.10 | B532
| | cistern | | |
| | | | |
| B533 | Surface mounted chrome-plated toilet | no | 20.15 | B533
| | roll holder with roller fixed to wall. | | |
| | | | |

PAGE 79 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| B534 | Surface mounted plastic toilet roll | no | 11.75 | B534
| | holder with plastic roller fixed to wall. | | |
| | | | |
| B535 | Plastic roller fixed in existing toilet | no | 1.05 | B535
| | roll holder brackets | | |
| | | | |
| B536 | Stainless steel surface mounted paper | no | 80.55 | B536
| | holder of size : 280 x 152 x 165mm | | |
| | "Global, G51" or approved equivalent | | |
| | | | |
| B537 | Stainless steel surface mounted paper | no | 32.25 | B537
| | holder of size : 127 x 89 x 102mm | | |
| | "Global, GP22A" or approved equivalent | | |
| | | | |
| B538 | Surface mounted Stainless Steel soap | no | 62.50 | B538
| | dispenser approx. size 205 x 110 x 75 | | |
| | (Depth)mm (Rigel SD-101 or SD-102 or | | |
| | approved equivalent) | | |
| | | | |
| B539 | Horizontal all-purpose valve | no | 72.15 | B539
| | (Model CV-025A)stainless steel liquid | | |
| | soap dispenser constructed of C.P. brass | | |
| | with Buna-N "O" ring makings with | | |
| | engineering plastic moving parts and | | |
| | push-in type valve projecting 61mm. | | |
| | | | |
| B540 | Soap dispenser "Global ASI-0332, USA, | no | 56.40 | B540
| | Global ASI-0343, USA" or approved | | |
| | equivalent | | |
| | | | |
| B541 | Hand dryer "Medictinics Prima M-96A", | no | 227.20 | B541
| | "Rigel AHD-101" or approved equivalent | | |
| | | | |
| B542 | Surface mounted brass chrome-finish | no | 38.35 | B542
| | liquid soap dispenser approx. size | | |
| | 190mm(L) x 82mm(W) (Rigel SD-106 or | | |
| | approved equivalent) | | |
| | | | |
| B543 | Mild steel brackets for wall hung | no | 4.00 | B543
| | cisterns including cutting and pinning | | |
| | to walls | | |
| | | | |
| B544 | 13mm diameter light gauge metal | no | 3.55 | B544
| | flexible inlet tube to cisterns/basins | | |
| | and taps complete with connectors | | |
| | | | |
| B545 | Miniature ball valves for basin and | no | 4.30 | B545
| | cistern | | |
| | | | | Updated

PAGE 80 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| B546 | Adjustable Chrome-Plated | no | 12.70 | B546
| | copper shower rose including fixing | | |
| | accessories to wall. | | |
| | | | |
| B547 | Rectangular lavatory mirror (Approx. | no | 16.15 | B547
| | size 400x350mm) including matching | | |
| | screws | | |
| | | | |
| B548 | 20mm diameter stainless steel handle of | no | 22.35 | B548
| | length 240mm at public toilet | | |
| | | | |
| | * Water tank valves and accessories | | |
| | *(B549 B560) | | |
| | | | |
| B549 | 40mm diameter high pressure equilibrium | no | 135.05 | B549
| | ball float valve (screw end 'Peglers' or | | |
| | approved equivalent) complete with | | |
| | copper float to water tank (DZR type) | | |
| | | | |
| B550 | 50mm diameter high pressure equilibrium | no | 261.85 | B550
| | ball float valve (screw end 'EBCO | | |
| | Fig.1031' or approved equivalent) | | |
| | complete with copper float to water | | |
| | tank (DZR type) | | |
| | | | |
| B551 | 75mm diameter high pressure equilibrium | no | 672.40 | B551
| | ball float valve (screw end 'EBCO | | |
| | Fig.1031' or approved equivalent) | | |
| | complete with copper float to water | | |
| | tank (DZR type) | | |
| | | | |
| B552 | 100mm diameter high pressure | no | 1,035.65 | B552
| | equilibrium ball float valve (screw end | | |
| | 'EBCO Fig.1031' or approved equivalent) | | |
| | complete with copper float to | | |
| | water tank (DZR type) | | |
| | | | |
| B553 | 100mm diameter high pressure | no | 732.80 | B553
| | equilibrium ball float valve (screw end | | |
| | 'EBCO Fig.1031' or approved equivalent) | | |
| | to water tank (DZR type) Rate exclude | | |
| | copper float | | |
| | | | |
| B554 | Lever stem to 40/50mm diameter | no | 17.95 | B554
| | equilibrium ball float valve | | |
| | | | |
| B555 | Lever stem to 75/100mm diameter | no | 22.80 | B555
| | equilibrium ball float valve | | |
| | | | |
| B556 | 300mm diameter copper ball float to | no | 216.20 | B556
| | water tank | | |
| | | | |

PAGE 81 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| B557 | 400mm diameter copper ball float to | no | 320.80 | B557
| | water tank | | |
| | | | |
| B558 | 75mm diameter rubber cup washer for | no | 10.20 | B558
| | 100mm diameter ball float valve | | |
| | | | |
| B559 | 80mm diameter high pressure rubber | no | 66.90 | B559
| | expansion joint for pumpset including | | |
| | fixing accessories | | |
| | | | |
| B560 | 1800mm high aluminium catladder with | no | 114.25 | B560
| | internal width of 350mm c/w 2 nos of | | |
| | 200mm centre bracket, 2 nos of rubber | | |
| | toes and 2 nos of floor bracket | | |
| | | | |
| B561 | 750mm diameter aluminium framed | no | 233.85 | B561
| | chequered plate cover for grease | | |
| | interceptor for eating house/canteen | | |
| | | | |
| B562 | Mild steel cover and frame 300 x 300mm | no | 15.95 | B562
| | for waste water down pipe sump. | | |
| | | | |
| B563 | 13mm diameter bolts, nuts and washers | no | 2.10 | B563
| | for flange joint or other fitting. | | |
| | | | |
| B564 | Stainless steel clamp for repair to | no | 6.50 | B564
| | leaking 40mm diameter pipe | | |
| | | | |
| B565 | Stainless steel clamp for repair to | no | 9.75 | B565
| | leaking 50mm diameter pipe | | |
| | | | |
| B566 | Stainless steel clamp for repair to | no | 12.90 | B566
| | leaking 75mm diameter pipe | | |
| | | | |
| B567 | 17mm wide punched steel for hanging | no | 2.30 | B567
| | cast iron pipe etc. (Band not exceeding | | |
| | 1.0 metre long) | | |
| | | | |
| B568 | 19/25mm diameter jet spray or discharge | no | 35.90 | B568
| | nozzle with ON/OFF handle. | | |
| | | | |
| B569 | Hack out existing pointing at joint | job | 2.40 | B569
| | between sink and wall and repoint in | | |
| | white cement | | |
| | | | |
| B570 | Repair to defective ball cock of water | no | 5.05 | B570
| | tank including renewing washer | | |
| | | | |
| B571 | Repair to defective w.c. cistern | no | 4.60 | B571
| | including renewing washer | | |
| | | | |

PAGE 82 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| B572 | Hack hole through wall/floor/roof slabs | open'g | 7.25 | B572
| | not exceeding 150mm thick to form chase | | |
| | for entry of water service pipes and | | |
| | make good disturbed areas to match | | |
| | existing on completion of pipe | | |
| | installation | | |
| | | | |
| B573 | Hack brick/hollow block wall and make | joint | 28.90 | B573
| | good leak in concealed pipe joint | | |
| | including patching up and painting to | | |
| | match existing | | |
| | | | |
| | * Re-caulk and make good joints of cast | | |
| | iron soil or waste pipes including | | |
| | raking out and providing additional | | |
| | molten lead and spun yarn if required. | | |
| | *(B574 B576) | | |
| | | | |
| B574 | 75mm diameter | no | 3.25 | B574
| | | | |
| B575 | 100mm diameter | no | 4.20 | B575
| | | | |
| B576 | 150mm diameter | no | 5.15 | B576
| | | | |
| | * Re-caulk and make good joints of cast | | |
| | iron rising main including raking out | | |
| | and providing additional spun yarn and | | |
| | molten lead if required in upright | | |
| | position *(B577 B578) | | |
| | | | |
| B577 | 100mm diameter | no | 4.20 | B577
| | | | |
| B578 | 150mm diameter | no | 5.15 | B578
| | | | |
| | * Re-caulk and make good joints of cast | | |
| | iron rising mains on level ground | | |
| | including raking out and providing | | |
| | additional spun yarn and molten | | |
| | lead if required. *(B579 B580) | | |
| | | | |
| B579 | 100mm diameter | no | 4.20 | B579
| | | | |
| B580 | 150mm diameter | no | 5.15 | B580
| | | | |
| | * Cut cast iron rising mains and jointing | | |
| | with Gilbault coupling *(B581 B582) | | |
| | | | |
| B581 | 100mm diameter | no | 28.55 | B581
| | | | |
| B582 | 150mm diameter | no | 49.65 | B582
| | | | |

PAGE 83 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| B583 | Repair to leaking cleaning eyes/oval | no | 3.05 | B583
| | shape inspection covers of cast iron | | |
| | soil and waste pipes of 75mm and above | | |
| | in diameter | | |
| | | | |
| B584 | Clear obstructions in traps of basins | job | 2.75 | B584
| | or sinks and water meter pipes including | | |
| | cleaning up areas on completion | | |
| | | | |
| B585 | Clear obstructions in floor traps, | job | 4.10 | B585
| | gulley traps and urinal trap | | |
| | | | |
| B586 | Clear obstructions in w.c. pan | job | 23.90 | B586
| | | | |
| B587 | Clear obstructions in soil and waste | job | 13.65 | B587
| | stack | | |
| | | | |
| B588 | Clear obstructions in sullage water or | job | 6.85 | B588
| | rain water down pipes right through to | | |
| | sumps or house drains | | |
| | | | |
| B589 | Clear obstruction in sullage water or | no | 7.15 | B589
| | rain water down pipe right through to | | |
| | sumps or house drains by high pressure | | |
| | water jetting equipment and electro- | | |
| | mechanical clearing equipment. | | |
| | | | |
| | * To locate and clear chokes in sewer/ | | |
| | grease lines and ensure smooth flow of | | |
| | waste water/solids including disposal of | | |
| | all choked waste *(B590 B593) | | |
| | | | |
| B590 | Manual clearing by approved rods | job | 20.50 | B590
| | | | |
| B591 | Mechanised clearing of chokes in | job | 33.10 | B591
| | sewer-lines by high pressure water | | |
| | jetting equipment < 2000psi) and/or | | |
| | electro-mechanical sewer clearing | | |
| | equipment. | | |
| | | | |
| B592 | Lorry mounted high pressure water | job | 241.50 | B592
| | jetting (up to 4000 PSI) and electro- | | |
| | machine to clear sewage pipe choke | | |
| | | | |
| B593 | Clear obstructions in waste water | job | 20.50 | B593
| | interceptor trap | | |
| | | | |
| B594 | Labour for clearing obstructions in | job | 4.10 | B594
| | traps of street gulleys including | | |
| | removal of solid waste from strainer | | |
| | | | |

PAGE 84 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| B595 | Clearing, flushing with water, | job | 120.75 | B595
| | cleaning, including scraping hardened | | |
| | oil sludge, debris etc. off grease trap | | |
| | /interceptor using high pressure water | | |
| | jetting and electro-mechanical equipment | | |
| | including vacuum cleaning of solids and | | |
| | semi-solids and remove debris off site. | | |
| | | | |
| B596 | Clear obstruction in grease gulley trap | job | 4.10 | B596
| | | | |
| B597 | Clear, flush with water, clean | m | 2.65 | B597
| | including scraping hardened oil sludge | | |
| | off sewer lines including manholes at | | |
| | house sewers using high pressure water | | |
| | jetting and/or electro-mechanical | | |
| | equipment including a squeegee or plug | | |
| | test for the sewer pipe on completion | | |
| | of the work and removing all debris off | | |
| | site. (Length of sewer line is measured | | |
| | through the manholes) | | |
| | | | |
| B598 | Flush concealed apron drain lines and | m | 1.45 | B598
| | sumps including removing debris from | | |
| | site. (Rate is also applicable for | | |
| | sullage water lines) | | |
| | | | |
| B599 | Service 80mm to 100mm diameter check | no | 4.10 | B599
| | valve | | |
| | | | |
| B600 | Repair leakage of 80mm to 100mm | no | 8.80 | B600
| | diameter cast iron gate valve including | | |
| | renewing gaskets | | |
| | | | |
| B601 | Refix loose sanitary accessories such | no | 2.10 | B601
| | as mirrors, brackets etc. | | |
| | | | |
| B602 | Adjust stop cock to tilt towards any | no | 2.10 | B602
| | direction specified including making | | |
| | good any damaged or affected piping | | |
| | work | | |
| | | | |
| B603 | Deposit sand granules (mosquito | no | 2.30 | B603
| | insecticide) into w.c. cistern, water | | |
| | seal in w.c. pans (squat / pedestal), | | |
| | gully traps and floor trap etc including | | |
| | covering with 50 micron transparent | | |
| | plastic sheet sealed with masking tape. | | |
| | (Rate inclusive of shuttering off water | | |
| | supply and draining off remaining water | | |
| | in w.c. pan and cistern if necessary. | | |
| | | | |

PAGE 85 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| B604 | Deposit sand granules (mosquito | no | 4.60 | B604
| | insecticide) into w.c. cistern, water | | |
| | seal in w.c. pans (squat/pedestal), | | |
| | gully traps and floor trap etc including | | |
| | covering with frosted window film which | | |
| | should at least cover the porcelain | | |
| | border of the w.c. pans (squat/pedestal) | | |
| | (Rate inclusive of shutting off water | | |
| | supply and draining off remaining water | | |
| | in w.c. pan and cistern if necessary). | | |
| | | | |
| | * Repair leaking joints of galvanised | | |
| | service pipes *(B605 B609) | | |
| | | | |
| B605 | Not exceeding 25mm diameter | job | 4.40 | B605
| | | | |
| B606 | Exceeding 25mm diameter but not | job | 5.90 | B606
| | exceeding 50mm diameter | | |
| | | | |
| B607 | Exceeding 50mm diameter but not | job | 11.95 | B607
| | exceeding 100mm diameter | | |
| | | | |
| B608 | Exceeding 100mm diameter | job | 18.25 | B608
| | | | |
| B609 | 100mm diameter full clamp to stop water | no | 102.70 | B609
| | leakage from burst pipe | | |
| | | | |
| | * Cowling/balloon grating and clips. | | |
| | *(B610 B611) | | |
| | | | |
| B610 | 100mm diameter UPVC vent cowl to vent | no | 4.40 | B610
| | pipe | | |
| | | | |
| B611 | 150mm diameter UPVC vent cowl to vent | no | 6.30 | B611
| | pipe | | |
| | | | |
| | * Painting to water tank *(B612 B619) | | |
| | | | |
| B612 | Prepare, scrap, remove rust and | m2 | 0.65 | B612
| | encrustation's and other sediments from | | |
| | internal sides and bottom of mild steel | | |
| | tanks including removal of existing | | |
| | mosquito netting (if any), flush and | | |
| | clean surfaces, bracings and mop up with | | |
| | cloth to dry to receive new painting | | |
| | (painting measured separately). (Note : | | |
| | Only where painting is required) | | |
| | | | |

PAGE 86 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| B613 | Prepare and paint internal surfaces of | m2 | 1.25 | B613
| | mild/stainless steel water tanks | | |
| | including bracing with one coat of rust | | |
| | converter (Water Base). | | |
| | | | |
| B614 | Prepare and paint internal surfaces of | m2 | 2.40 | B614
| | mild/stainless steel water tanks | | |
| | including bracing with two finishing | | |
| | coats of rust convertor (water Base). | | |
| | | | |
| B615 | Prepare and paint internal surfaces of | m2 | 5.90 | B615
| | mild/stainless steel water tanks | | |
| | including bracing with two finishing | | |
| | coats (Epoxy Base). | | |
| | | | |
| B616 | Prepare and paint external surfaces of | m2 | 1.25 | B616
| | mild/stainless steel water tanks with | | |
| | one coat of rust converter (Water Base). | | |
| | | | |
| B617 | Prepare and paint external surfaces of | m2 | 2.75 | B617
| | mild/stainless steel water tanks with | | |
| | one coat of primer (Epoxy Base) | | |
| | | | |
| B618 | Prepare and paint external surfaces of | m2 | 2.85 | B618
| | mild/stainless steel water tanks with | | |
| | one finishing coating (Water Base) | | |
| | | | |
| B619 | Prepare and paint external surfaces of | m2 | 4.10 | B619
| | mild/stainless steel water tanks with | | |
| | one finishing coating (Epoxy Base) | | |
| | | | |
| B620 | Patch holes in tank walls/bottoms/ | no | 27.70 | B620
| | covers by welding new pieces of plates | | |
| | (including the cost for use, | | |
| | transportation and removal of welding | | |
| | equipment) | | |
| | | | |
| B621 | Repair leaking joints of water storage | m | 3.55 | B621
| | tank with non-toxic sealing compound | | |
| | including tightening of all bolts and | | |
| | nuts | | |
| | | | |
| B622 | Repair leaking joints of FRP tank | panel | 12.70 | B622
| | including dismantling panels, | | |
| | replacements of gaskets, bolts, nuts | | |
| | and refixing | | |
| | | | |
| B623 | 100mm diameter galvanised steel spring | no | 4.30 | B623
| | clip with nylon nettings cover at outlet | | |
| | of over flow pipe | | |
| | | | |

PAGE 87 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| B624 | New nylon mosquito mesh to open tanks | m2 | 1.35 | B624
| | including non-toxic sealing compound, | | |
| | and removal of existing mesh, if any | | |
| | | | |
| B625 | 0.65mm thick corrugated colour coated | m2 | 39.50 | B625
| | galvanised steel cover in replacement | | |
| | | | |
| B626 | Seal up gaps along edges between covers | m | 1.05 | B626
| | and tanks with new nylon mosquito mesh | | |
| | and non-toxic sealing compound including | | |
| | removal of existing mesh, if any | | |
| | | | |
| B627 | Seal up gaps along edges between covers | m | 1.15 | B627
| | and tanks with new nylon mosquito mesh | | |
| | in two layers with non-toxic sealing | | |
| | compound including removal of existing | | |
| | mesh, if any | | |
| | | | |
| B628 | 75 x 75 x 6mm thick angle iron bracing/ | m | 6.10 | B628
| | stay to water tank (including bolts and | | |
| | nuts etc) | | |
| | | | |
| B629 | Extra over on item (B628) for | m | 1.35 | B629
| | dismantling and removing of existing | | |
| | bracing/stay off site | | |
| | | | |
| B630 | M12 (55mm)/M16 (40mm) stainless steel | no | 2.30 | B630
| | (SS316) bolts and nuts with 2 nos washer | | |
| | to water tank | | |
| | | | |
| B631 | Stainless steel bolts to joints of | no | 3.55 | B631
| | stainless steel water tank c/o 40mm long | | |
| | SS316 M16 bolt, nut and 2 washers | | |
| | including removal of existing. | | |
| | | | |
| B632 | Stainless steel bolts to joints of | set | 3.90 | B632
| | stainless steel water tank c/o 4 nos of | | |
| | 55mm long SS 316 M12 bolts, nuts, 8 nos | | |
| | washers and 1 no 225 x 220 x 5mm thick | | |
| | PVC foam gasket including removal of | | |
| | existing. | | |
| | | | |
| B633 | Repair leaking joints of link pipe | joint | 13.85 | B633
| | jointing to water storage tanks | | |
| | including necessary gaskets, sealing | | |
| | compound etc | | |
| | | | |
| B634 | Float switch to higher/lower water tank | no | 45.90 | B634
| | complete with bracket including | | |
| | dismantling and removal of existing | | |
| | float switch off site | | |
| | | | |

PAGE 88 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| B635 | Inspection cover to mild steel water | no | 34.35 | B635
| | tank including removing old frame and | | |
| | making good works disturbed | | |
| | | | |
| B636 | White glazed wall tiles including | m2 | 37.80 | B636
| | rounded edge tiles and 1:3 cement & | | |
| | sand mortar screed to concrete water | | |
| | tank in replacement | | |
| | | | |
| B637 | Form opening through top/side/bottom of | open'g | 7.05 | B637
| | water tank for the entry of pipe not | | |
| | exceeding 150mm diameter including | | |
| | making good works disturbed, | | |
| | connection of pipe and drilling holes | | |
| | for bolts | | |
| | | | |
| B638 | Dismantle bulging water tank panel and | panel | 6.60 | B638
| | refix to proper shape including flushing | | |
| | out of water (provision of additional | | |
| | angle steel bracings/stays measured | | |
| | separately). | | |
| | | | |
| B639 | 3660 x 1830mm (in panel form) | no | 1,104.50 | B639
| | galvanised steel water tank roof cover | | |
| | including one inspection opening with | | |
| | cover | | |
| | | | |
| B640 | Refix fallen off water tank cover. | m2 | 6.60 | B640
| | (Provision of additional angle supports, | | |
| | bolts and nuts measured separately) | | |
| | | | |
| B641 | Repair leakage at jamb nut including | no | 2.30 | B641
| | flushing out of water if necessary and | | |
| | tightening jamb nut. | | |
| | | | |
| B642 | Dismantle and remove from site existing | cover | 46.40 | B642
| | damaged inspection cover including the | | |
| | 150mm high four-sided galvanised steel | | |
| | boxing to the access hole and replace | | |
| | with 0.559mm thick galvanised steel | | |
| | cover overall size 490 x 490mm including | | |
| | boxing up the access hole with 150mm x | | |
| | 0.559mm thick galvanised steel including | | |
| | pop-riveting and making good. | | |
| | | | |
| B643 | Flushing of steel strainer located | no | 6.85 | B643
| | after PUB Bulk Meter including | | |
| | dismantling and refixing | | |
| | | | |
| B644 | Pressure gauge 0 to 60 psi and 0 to 4 | no | 30.65 | B644
| | kg/cm2 for booster pumping system | | |
| | | | |

PAGE 89 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| B645 | Prepare, remove all stains and | m2 | 0.30 | B645
| | sediments from internal sides and bottom | | |
| | of tanks, flush and clean surfaces, | | |
| | including bracing to mild steel water | | |
| | tank. (Note: Only when painting is NOT | | |
| | required) | | |
| | | | |
| B646 | Prepare, sand and remove rust, stains | m2 | 0.30 | B646
| | and other sediments from internal sides | | |
| | and bottom of tanks, flush and clean | | |
| | surfaces, including bracing to stainless | | |
| | steel water tank | | |
| | | | |
| B647 | Clean and remove rust stains from | m2 | 0.20 | B647
| | External surface of stainless steel | | |
| | water tanks | | |
| | | | |
| B648 | Prepare, remove all rust, stains and | m2 | 0.20 | B648
| | sediments from internal sides and bottom | | |
| | of tanks, flush and clean surface to | | |
| | FRP/GRP or R.C. Water Tanks | | |
| | | | |
| B649 | Flush roof top water storage tanks and | job | 8.30 | B649
| | refill with clean water upon completion. | | |
| | | | |
| B650 | Testing of water samples including | sample | 68.65 | B650
| | transportation from site and submission | | |
| | of test reports for both bacteriological | | |
| | and chemical tests | | |
| | | | |
| B651 | Analyses on sample of water for grease | sample | 48.30 | B651
| | & oil | | |
| | | | |
| B652 | Roll steel joists for support of tanks, | kg | 2.40 | B652
| | including hoisting, fixing in position | | |
| | and removal of existing joists if any | | |
| | (Painting measured separately) | | |
| | | | |
| B653 | Labour to carry out fortnightly or | system | 16.50 | B653
| | monthly inspection of either the | | |
| | transfer pump or booster pump | | |
| | installation including all necessary | | |
| | tools, etc. (Note: 1 pumping system | | |
| | consist of 2 nos. pumpsets) | | |
| | | | |
| B654 | Labour to carry out fortnightly or | system | 16.50 | B654
| | monthly inspection of both the transfer | | |
| | pump and booster pump installation | | |
| | including all necessary tools, etc. | | |
| | (Note: 1 pumping system consists of 2 | | |
| | pumpsets) | | |
| | | | |

PAGE 90 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SANITARY (CONT'D) | | |
| | | | |
| B655 | Labour and material for sterilisation | m3 | 0.55 | B655
| | of mild steel/FRP/polyethylene lined/ | | |
| | stainless steel/concrete water storage | | |
| | or suction tank to overflow level | | |
| | | | |
| B656 | 500 litres CIMM tank for booster pump | no | 1,023.75 | B656
| | system inclusive of dismantling & | | |
| | disposal of existing tank | | |
| | | | | New
| B657 | White vitreous china pedestal w.c. suit valve | no | 162.70 | B657
| | type c/w flushing cistern close-coupled with | | |
| | pedestal water closet pan and approved fitting | | |
| | excluding seat and cover (Claytan | | |
| | or approved equivalent) | | |
| | | | |
| | DAYWORK | | |
| | | | |
| | * Rates for labour and plant | | |
| | Exclude 15% establishment charges and | | |
| | profit. *(C001 C041) | | |
| | | | | Bldg SOR
| C001 | Labourer | hr | 4.40 | S/n 1038
| | | | |
| C002 | Concretor | hr | 6.30 | S/n 1029
| | | | |
| C003 | Pavior | hr | 6.00 | S/n 1043
| | | | |
| C004 | Plasterer | hr | 6.30 | S/n 1045
| | | | |
| C005 | Brick layer | hr | 6.20 | S/n 1026
| | | | |
| C006 | Tiler | hr | 6.90 | S/n 1052
| | | | |
| C007 | Ironmonger | hr | 6.70 | S/n 1036
| | | | |
| C008 | Steelworker | hr | 5.80 | S/n 1051
| | | | |
| C009 | Welder | hr | 6.20 | S/n 1055
| | | | |
| C010 | Roofer | hr | 6.70 | S/n 1048
| | | | |
| C011 | Joiner | hr | 6.80 | S/n 1037
| | | | |
| C012 | Carpenter | hr | 5.40 | S/n 1028
| | | | |
| C013 | Painter | hr | 6.20 | S/n 1042
| | | | |
| C014 | Glazier | hr | 6.30 | S/n 1035
| | | | |
| C015 | Plumber | hr | 6.00 | S/n 1046
| | | | | Bldg TC

PAGE 91 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | DAYWORK (CONT'D) | | |
| | | | |
| C016 | Licensed Plumber | hr | 10.90 | C016
| | | | |
| C017 | Electrician | hr | 6.60 | C017
| | | | |
| C018 | Wireman | hr | 6.30 | S/n 1056
| | | | |
| C019 | 2.5-3 tonne lorry/ tipper including | hr | 17.30 | S/n 1065
| | fuel and driver | | |
| | | | |
| C020 | 5.5-7 tonne motor lorry including fuel | hr | 19.05 | S/n 1066
| | and driver | | |
| | | | |
| C021 | Crane (Kato KR 20H) including fuel and | hr | 62.30 | S/n 1060
| | driver. | | |
| | | | | Bldg TC
| C022 | 80ft (approx. 24.38m) Boomlift | day | 570.00 | C022
| | including maintenance, diesel, operator | | |
| | and to/fro transportation. | | |
| | | | | Bldg TC
| C023 | 100ft (approx. 30m) Boomlift including | day | 666.20 | C023
| | maintenance, diesel, operator and | | |
| | to/fro transportation. | | |
| | | | | Bldg TC
| C024 | Self propelled 'scissor' lift with | day | 40.80 | C024
| | working platform up to maximum height of | | |
| | approximately 7.62m(25ft) including | | |
| | to/fro transportation. | | |
| | | | |
| C025 | Air compressor with air deliver of 4.5 | hr | 13.90 | S/n 1057
| | cu m and working pressure of 7 kg/cm2 | | |
| | including pneumatic tools, fuel and tool | | |
| | sharpening (no labour) | | |
| | | | |
| C026 | Diesel powered field welding machine | hr | 7.70 | S/n 1061
| | (300 Amp). | | |
| | | | |
| C027 | Wheel or crawler shovel or excavator | hr | 41.20 | S/n 1076
| | loader with back hoe bucket not | | |
| | exceeding 0.4 cu m or 1.3 cu m loader | | |
| | bucket capacity including fuel and driver | | |
| | | | |
| C028 | Power loader on rubber-tyred wheels | hr | 35.55 | S/n 1070
| | 1.20 cu m bucket capacity (Flywheel | | |
| | horsepower 60 KW range) including fuel | | |
| | and driver | | |
| | | | |
| C029 | Traxcavator 1.0 cu m capacity including | hr | 43.25 | S/n 1073
| | fuel and driver. | | |
| | | | |
| C030 | 50mm water pump including fuel | hr | 8.55 | C030
| | | | |

PAGE 92 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | DAYWORK (CONT'D) | | |
| | | | |
| C031 | Mobilization of truck mounted concrete | job | 550.00 | C031
| | pump including fuel and driver | | |
| | | | |
| C032 | Erection of double layer metal scaffolding | m2 | 6.95 | C032
| | complying with safety regulation including | | |
| | taking down after (irregardless of height) | | |
| | (PE fees not included) | | |
| | | | |
| C033 | Mobile stagging compliance with safety | no | 81.00 | C034
| | regulation and taking down after use. | | |
| | (per job duration) | | |
| | | | |
| C034 | Erection of single layer timber | m2 | 2.90 | C035
| | scaffolding including taking down after | | |
| | use | | |
| | | | |
| C035 | Erect double layer timber scaffolding | m2 | 6.00 | C036
| | including taking down after use | | |
| | | | |
| C036 | Submission of drawing and roof plans by | block | 350.00 | C037
| | Professional Engineer to the relevant | | |
| | Authorities for approval (building | | |
| | having similar roof plans/ design shall | | |
| | be included in this rate and shall NOT | | |
| | be paid separately under one operation). | | |
| | | | |
| C037 | To carry out testing of mechanical | no | 200.00 | C038
| | suspended cradles by Professional | | |
| | engineer and obtain approval from the | | |
| | relevant authorities. | | |
| | | | |
| C038 | Supply and install mechanical suspended | no | 1,000.00 | C039
| | cradles not exceeding 5m length to the | | |
| | roof including application/submission of | | |
| | electricity supply to various | | |
| | authorities for approval by approved | | |
| | licensed electrical workers (hiring | | |
| | charges and shifting shall be paid | | |
| | separately). | | |
| | | | |
| C039 | Hiring charge of approved mechanical | day | 40.00 | C040
| | suspended cradle not exceeding 5m length | | |
| | including all accessories and safety | | |
| | precautions | | |
| | | | |
| C040 | Labour for shifting approved mechanical | Job | 35.90 | C041
| | suspended cradle within the same block. | | |
| | | | |
| C041 | Erection of double layer metal scaffolding | m2 | 25.00 | C041
| | complying with safety regulation including | | |
| | taking down after (irregardless of height) | | |
| | (inclusive of PE fees) | | |
| | | | |

PAGE 93 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SUPPLEMENTARY SCHEDULE OF RATES | | |
| | | | |
| | Reinstatement Works | | |
| | | | |
| D001 | Dismantling of Mezzanine floors all | m2 | 2.40 | D001
| | as specified in Clause 49.3. | | |
| | | | |
| D002 | Dismantling of Storage Platform all | m2 | 2.40 | D002
| | as specified in Clause 49.3. | | |
| | | | |
| D003 | Dismantling of office/storeroom | m2 | 3.00 | D003
| | all as specified in Clause 49.4 for | | |
| | partition walls. | | |
| | (Based on floor area) | | |
| | | | |
| D004 | Dismantling of office/storeroom | m2 | 2.00 | D004
| | all as specified in Clause 49.4 for | | |
| | false ceiling. | | |
| | (Based on floor area) | | |
| | | | |
| D005 | Dismantling of fixed wall cabinets/ | m | 6.50 | D005
| | shelves all as specified in Clause 49.5. | | |
| | | | |
| | * Painting works to internal of units as | | |
| | specified in Clause 49.6.1 to the | | |
| | following internal floor areas: *(D006 D016) | | |
| | | | |
| D006 | >50.00m2 but not >100.00m2. | unit | 460.00 | D006
| | | | |
| D007 | >100.00m2 but not >150.00m2. | unit | 590.00 | D007
| | | | |
| D008 | >150.00m2 but not >200.00m2. | unit | 700.00 | D008
| | | | |
| D009 | >200.00m2 but not >250.00m2. | unit | 760.00 | D009
| | | | |
| D010 | >250.00m2 but not >300.00m2. | unit | 820.00 | D010
| | | | |
| D011 | >300.00m2 but not >350.00m2. | unit | 880.00 | D011
| | | | |
| D012 | >350.00m2 but not >400.00m2. | unit | 990.00 | D012
| | | | |
| D013 | >400.00m2 but not >450.00m2. | unit | 1,450.00 | D013
| | | | |
| D014 | >450.00m2 but not >550.00m2. | unit | 1,530.00 | D014
| | | | |
| D015 | >550.00m2 but not >650.00m2. | unit | 1,630.00 | D015
| | | | |
| D016 | >650.00m2 but not >900.00m2. | unit | 1,760.00 | D016
| | | | |

PAGE 94 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SUPPLEMENTARY SCHEDULE OF RATES (CONT'D) | | |
| | | | |
| | * Painting works to Roof Purlins and | | |
| | Thrusts of units as specified with the | | |
| | following floor area of Internal unit: | | |
| | *(D017 D027) | | |
| | | | |
| D017 | >50.00m2 but not >100.00m2. | unit | 210.00 | D017
| | | | |
| D018 | >100.00m2 but not >150.00m2. | unit | 290.00 | D018
| | | | |
| D019 | >150.00m2 but not >200.00m2. | unit | 370.00 | D019
| | | | |
| D020 | >200.00m2 but not >250.00m2. | unit | 460.00 | D020
| | | | |
| D021 | >250.00m2 but not >300.00m2. | unit | 520.00 | D021
| | | | |
| D022 | >300.00m2 but not >350.00m2. | unit | 570.00 | D022
| | | | |
| D023 | >350.00m2 but not >400.00m2. | unit | 620.00 | D023
| | | | |
| D024 | >400.00m2 but not >450.00m2. | unit | 690.00 | D024
| | | | |
| D025 | >450.00m2 but not >550.00m2. | unit | 800.00 | D025
| | | | |
| D026 | >550.00m2 but not >650.00m2. | unit | 900.00 | D026
| | | | |
| D027 | >650.00m2 but not >900.00m2. | unit | 1,160.00 | D027
| | | | |
| | * Removal of electrical wirings & | | |
| | fittings installed by tenants including | | |
| | termination of power supply (as | | |
| | specified in clause 49.7) to the | | |
| | following floor areas of internal unit | | |
| | (whole unit). *(D028 D038) | | |
| | | | |
| D028 | >50.00m2 but not >100.00m2. | unit | 130.00 | D028
| | | | |
| D029 | >100.00m2 but not >150.00m2. | unit | 140.00 | D029
| | | | |
| D030 | >150.00m2 but not >200.00m2. | unit | 160.00 | D030
| | | | |
| D031 | >200.00m2 but not >250.00m2. | unit | 180.00 | D031
| | | | |
| D032 | >250.00m2 but not >300.00m2. | unit | 180.00 | D032
| | | | |
| D033 | >300.00m2 but not >350.00m2. | unit | 190.00 | D033
| | | | |
| D034 | >350.00m2 but not >400.00m2. | unit | 195.00 | D034
| | | | |
| D035 | >400.00m2 but not >450.00m2. | unit | 210.00 | D035
| | | | |
| D036 | >450.00m2 but not >550.00m2. | unit | 220.00 | D036
| | | | |

PAGE 95 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SUPPLEMENTARY SCHEDULE OF RATES (CONT'D) | | |
| | | | |
| D037 | >550.00m2 but not >650.00m2. | unit | 223.00 | D037
| | | | |
| D038 | >650.00m2 but not >900.00m2. | unit | 226.00 | D038
| | | | |
| D039 | Supply labour and tools to remove | m | 1.10 | D039
| | and dipose curtains, blinds and | | |
| | rails (if any) including patch up | | |
| | holes with approved non-shrink cement | | |
| | grout and painting to match existing. | | |
| | (regardless of height) | | |
| | | | |
| D040 | Supply and apply one coat penetrative | m2 | 2.70 | D040
| | solvent deposited primer/sealer coating | | |
| | and 2 coats single pack solvent | | |
| | deposited liquid dressing to external | | |
| | wall. | | |
| | | | |
| D041 | Supply and apply "Flexcoat" or other | m2 | 7.30 | D041
| | approved equivalent applied | | |
| | waterproofing membrane coating system | | |
| | to wall. | | |
| | | | | Updated
| D042 | Supply and apply 2 coats "Sonvacryl" | m2 | 14.90 | D042
| | or other approved equivalent | | |
| | flexible acrylic waterproofing membrane. | | |
| | | | |
| D043 | 10mm thick prepacked waterproof | m2 | 5.80 | D043
| | screed for kitchen, bath and WC floors | | |
| | as specified | | |
| | | | |
| D044 | Supply and apply 30mm x 15mm deep | m | 5.40 | D044
| | 'StoSeal' SPS A Grey sealant | | |
| | or other approved equivalent. | | |
| | | | |
| D045 | Supply and apply 30mm x 30mm deep | m | 9.70 | D045
| | 'StoSeal' SPS A Grey sealant | | |
| | or other approved equivalent. | | |
| | | | |
| D046 | Supply and apply 40mm x 20mm deep | m | 9.70 | D046
| | 'StoSeal' SPS A Grey sealant | | |
| | or other approved equivalent. | | |
| | | | |
| D047 | Supply and apply 110mm x 10mm deep | m | 12.20 | D047
| | 'StoSeal' SPS A Grey sealant | | |
| | or other approved equivalent. | | |
| | | | |
| D048 | Supply and install backing rod and | m | 3.60 | D048
| | non-shrink grout to expansion joint. | | |
| | | | |

PAGE 96 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SUPPLEMENTARY SCHEDULE OF RATES (CONT'D) | | |
| | | | |
| D049 | Supply and install backing rod | m | 9.50 | D049
| | cushioned by 20x10mm thick | | |
| | polyurethane sealant and non-shrink | | |
| | grout to expansion joint. | | |
| | | | |
| D050 | Supply and fix N6 welded steel fabric | m2 | 11.00 | D050
| | reinforcement well lapped and tied | | |
| | at joints (measured nett). | | |
| | | | |
| D051 | Supply and lay 'Quicseal 718' fibre | m2 | 2.30 | D051
| | or other approved equivalent | | |
| | fibre mesh. | | |
| | | | |
| D052 | Supply and fix 25mm diameter | no | 8.20 | D052
| | mild steel rod hinges. | | |
| | | | |
| D053 | Stainless steel knobset/night | no | 24.50 | D053
| | latch lockset "Union 9303/361" | | |
| | or other approved equivalent | | |
| | including anti-thrust latch | | |
| | | | |
| D054 | Supply and install 135 x 65 x 6mm | no | 21.60 | D054
| | brass hasp and staple at OG Box | | |
| | | | |
| D055 | Supply and install "J4LA600AB" | set | 49.10 | D055
| | or other approved equivalent lever | | |
| | handle entrance lockset under KA system. | | |
| | | | |
| D056 | Supply and install bronze anodised | m2 | 286.20 | Z037
| | extruded aluminium frame casement | | |
| | window with sheet float glass, aluminium | | |
| | fronting, ironmongery & cill with cement | | |
| | infill & all necessary fixing & jointing | | |
| | materials and accessories as specified | | |
| | with 6mm thk obscured rough cast | | |
| | wired glass. | | |
| | | | |
| D057 | Supply and install natural anodized | m2 | 180.00 | D057
| | aluminium fixed louvred vent with | | |
| | 2.3mm thick extruded aluminium louvred | | |
| | blades including all necessary fixing | | |
| | accessories. | | |
| | | | |
| D058 | Supply and install curved galvanised | m2 | 80.50 | D062
| | steel coils metal roof minimum | | |
| | 0.60mm thick coated with full strength | | |
| | fluoropolymer coating and complete with | | |
| | vinyl weatherseal as an integral part | | |
| | of Snap-On-Seam cover with 10 years | | |
| | | | |
| D059 | 1.0m high stainless steel railing - | m | 97.80 | D063
| | - 50mm dia x 2mm thick pipe as top, | | |
| | mid rail and balustrades at | | |
| | 1200mm c/c cast in concrete. | | |
| | | | |

PAGE 97 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SUPPLEMENTARY SCHEDULE OF RATES (CONT'D) | | |
| | | | |
| D060 | Removal of damaged 450mm diameter x | job | 429.90 | D064
| | 0.8mm thick galvanised steel duct, | | |
| | supply and installation of new | | |
| | 450mm diameter x 0.8mm thick galvanised | | |
| | steel duct. | | |
| | | | |
| D061 | Supply and installation of | m2 | 368.00 | D065
| | fluorocarbon coated aluminium | | |
| | 3mm thick bend sheet with perforation. | | |
| | | | |
| D062 | Supply and install 50mm thick | m2 | 293.30 | D066
| | Promatech 'H' or other approved | | |
| | equivalent 2 hour fire rated | | |
| | weatherproofed board panel to flue duct | | |
| | | | |
| D063 | Supply and install I-bracket inclusive | no | 24.20 | D067
| | of 40mmx3mm anchor plate, 4" U-bolt | | |
| | and 3/8mm wall plug (rate exclude | | |
| | staging used). | | |
| | | | |
| D064 | Supply and fix 25mm diameter | no | 57.30 | D068
| | galvanised steel bolt x 170mm long | | |
| | thread c/w 1 no. washer to stanchion | | |
| | plate of bollard (stanchion plate not | | |
| | included). | | |
| | | | |
| D065 | Filling up gaps/pot holes with "Davco | m3 | 1,496.80 | D069
| | Lapgrout 60" or other approved | | |
| | equivalent, including preparing | | |
| | gaps/pot holes to receive grouting. | | |
| | | | |
| D066 | Supply and apply 'Dinos' or | m2 | 0.60 | D070
| | other approved equivalent | | |
| | remover & tile cleaner acid to clean | | |
| | oily floor surface. | | |
| | | | |
| D067 | Supply and install foot-operated | no | 818.50 | D071
| | grade 304 SS refuse chute hopper to | | |
| | centralised refuse chute complete with | | |
| | all necessary fixing accessories | | |
| | including dismantling existing | | |
| | (Overall size:1100 x 700 x 1.5mm thick). | | |
| | | | |
| D068 | Supply and install 3000mm x 600mm x | m2 | 115.00 | D072
| | 2mm thick aluminium panel including | | |
| | 1 primer coat and 2 finishing coats | | |
| | of approved paint. | | |
| | | | |
| D069 | 2100mm diameter aluminium chequered | no | 782.00 | D073
| | plate covers including frame according | | |
| | to drawing. | | |
| | | | |
| D070 | Supply and install 150mm diameter | no | 117.00 | D074
| | class 'C' galvanised steel tee | | |
| | | | |

PAGE 98 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SUPPLEMENTARY SCHEDULE OF RATES (CONT'D) | | |
| | | | |
| D071 | Supply and install 100mm diameter | m | 282.90 | D075
| | class C heavy duty bolted gland ductile | | |
| | iron underground gas pipe. | | |
| | | | |
| D072 | Supply and install vulcanite plug | no | 3.10 | D076
| | complete with chain to fireclay | | |
| | sink/wash hand basin/ | | |
| | stainless steel sink. | | |
| | | | |
| D073 | Supply and fix 100mm ductile iron | no | 363.50 | D077
| | strainer. | | |
| | | | |
| D074 | Supply and fix 100mm rubber washer | no | 13.50 | D078
| | for leaking ball float valve. | | |
| | | | |
| D075 | Basin mounted soap dispenser | no | 40.30 | D079
| | "GAMCO G29L" or other approved | | |
| | equivalent. | | |
| | | | |
| D076 | Supply and fix (in replacement) | no | 28.50 | D080
| | 15mm diameter bottom-inlet ball valve | | |
| | comprise with ball valve for siphon | | |
| | unit for low capacity (water saving) | | |
| | cistern. | | |
| | | | |
| D077 | Supply and install 3 1/2" Johnson | no | 12.70 | D081
| | Suisse expansion fixing screw | | |
| | (Environ 3) for fixing Johnson Suisse | | |
| | cistern onto pedestal pan. | | |
| | | | |
| D078 | Supply and install 100mm diameter | m | 282.90 | D082
| | class C heavy duty bolted gland ductile | | |
| | iron underground gas pipe. | | |
| | | | |
| D079 | Supply and install 100mm diameter | no | 207.00 | D083
| | class C heavy duty bolted gland ductile | | |
| | iron bend | | |
| | | | |
| D080 | Supply and install friction stay | no | 9.50 | D084
| | not exceeding 300mm long including | | |
| | all fixing accessories. | | |
| | | | |
| D081 | Supply and install friction stay | no | 15.30 | D085
| | exceeding 300mm long including | | |
| | all fixing accessories. | | |
| | | | |
| D082 | Replacement of damaged rivet | no | 0.65 | D086
| | with approved stainless steel rivets. | | |
| | | | |
| D083 | Supply and install new manually- | m2 | 115.00 | D087
| | operated roller shutter door, "Gliderol" | | |
| | or other approved equivalent, in 0.5mm | | |
| | thick Lysaght's Colorbond finish, | | |
| | complete with all necessary proprietary | | |
| | fittings to suit opening size and | | |
| | excludes operator (removal of existing | | |
| | shall be paid separately) | | |

PAGE 99 OF 104
SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SUPPLEMENTARY SCHEDULE OF RATES (CONT'D) | | |
| | | | |
| D084 | Extra over to Item D083 for supply | set | 1,150.00 | D088
| | and install motor operator (electronic | | |
| | type) with control panel for electrical | | |
| | operated "Gliderol" or other approved | | |
| | equivalent roller shutter door. | | |
| | | | |
| D085 | Extra over to Item D083 for supply | set | 230.00 | D089
| | and install planetary gearing (complete | | |
| | set for manually operated "Gliderol" or | | |
| | other approved equivalent roller shutter | | |
| | door. | | |
| | | | |
| D086 | General servicing of roller shutter | door | 230.00 | D090
| | including easing, adjusting, greasing | | |
| | and sundries, etc. | | |
| | | | |
| D087 | Supply and install anodised | m2 | 91.30 | D091
| | extruded aluminium framed 2-track | | |
| | sliding window complete with 5mm | | |
| | thick clear sheet/float glass, | | |
| | ironmongery and all necessary | | |
| | fixing and jointing materials | | |
| | and accessories. | | |
| | | | |
| D088 | Supply labour and material to oil, | m2 | 0.50 | D092
| | adjust and ease adjustable lourve | | |
| | windows. | | |
| | | | |
| D089 | Supply labour and material to | m2 | 0.60 | D093
| | remove glue stain. | | |
| | | | |
| D090 | Supply labour and material to | no | 0.40 | D094
| | remove bolts below concrete surfaces | | |
| | including patch up holes with | | |
| | approved non-shrink cement grout. | | |
| | | | |
| D091 | Supply labour and material to | no | 1.30 | D095
| | remove signages, basins, clothes | | |
| | hanger, shower set, light fittings and | | |
| | eletrical board/box including patch up | | |
| | holes with approved non-shrink | | |
| | cement grout. | | |
| | | | |
| D092 | Supply labour and material to | m | 0.50 | D096
| | remove and dispose pipes, conduits | | |
| | and trunkings including patch up of | | |
| | holes to match existing. | | |
| | | | |
| D093 | Supply and install 75mm | no | 4.20 | D097
| | brass shoot bolt. | | |
| | | | |
| D094 | Supply and install cam lock | no | 6.50 | D098
| | for roller shutter panel door | | |
| | | | |
| D095 | Waist high lock for 'Gliderol' or other | no | 40.50 | D099
| | approved equivalent roller shutter door. | | |
| | | | |

PAGE 100 OF 104


SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SUPPLEMENTARY SCHEDULE OF RATES (CONT'D) | | |
| | | | |
| D096 | Wash stained toilet floors with approved | toilet | 16.30 | D100
| | chemical (for Zone 1A, 1B, 2A, 2B, 3A & 3B). | | |
| | | | |
| D097 | Wash stained toilet wall tiles, doors | toilet | 16.30 | D101
| | and all sanitary fittings with | | |
| | approved chemical (for Zone 1A, 1B, | | |
| | 2A, 2B, 3A & 3B). | | |
| | | | |
| D098 | Supply labours, tools and detergent to | Day | 46.80 | Z001
| | clean down provisional result | | |
| | unit (regardless of floor area) and | | |
| | inclusive of mobile stagging to the | | |
| | following: - Both faces of windows, | | |
| | vents, doors and shutters; wall/floor tiles, | | |
| | concrete floor and sanitary fittings | | |
| | | | |
| D099 | Extra over for attending to emergency | Job | 15.00 | HKK's Dra
| | work instructed by HDB's EMS Contractor | | |
| | or SO Reps (Clause 48.6) after office | | |
| | hours (Mon - Fri - 6:01pm to 7:59am and | | |
| | Sat - after 1:00pm), Sunday and Public | | |
| | Holiday (for Zone 4A & 4B) | | |
| | | | |
| D100 | Supply and install copper reducer | no | 17.40 | Z004
| | from 65mm to 50mm. | | |
| | | | |
| D101 | Supply labour and material to box | no | 256.00 | SR 2398
| | up duct outlet inside unit including | | | Star-rate
| | provision of scaffolding. | | | Site TO
| | (Blk 3017 Gourmet East Kitchen) | | |
| | | | | Jan-06
| D102 | 25mm thick concrete screed (Grade 25) | m2 | 5.90 | Bldg SOR
| | with 10mm maximum size aggregate to | | | S/n 280
| | concrete floor surfaces finished with | | |
| | steel trowelling including all necessary | | |
| | labour and materials for preparation | | |
| | of substrate's surface to receive screed | | | Jan-06
| | as specified | | | Bldg SOR
| | | | |
| D103 | Add to (or deduct from) item D102 for | m2 | 0.90 | S/n 281
| | each 5mm thickness over (or under) | | |
| | 25mm thick. | | | Jan-06
| | | | | Bldg SOR
| D104 | Extra over concrete floor or screed for | m2 | 7.70 | S/N 264
| | the application of approved non-metallic | | |
| | hardener with power trowelled finish | | |
| | including spraying a coat of approved | | |
| | curing agent onto the finish surface | | |
| | as specified. | | | Jan-06
| | | | | Bldg SOR

PAGE 101 OF 104


SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SUPPLEMENTARY SCHEDULE OF RATES (CONT'D) | | |
| | | | |
| D105 | 20mm thick prepacked screed to | m2 | 6.80 | S/N 272
| | floor trowelled to a smooth finish | | | Jan-06
| | | | | Bldg SOR
| D106 | Add to (or deduct from) item D105 for | m2 | 1.40 | S/N 273
| | each 5mm thickness over (or under) | | |
| | 20mm thick | | |
| | | | |
| D107 | Supply and lay 108x108x 5mm thk | m2 | 32.60 | z006
| | white glazed wall tiles including | | |
| | cement & sand mortar (1:2:5) based | | |
| | screed. | | |
| | | | |
| D108 | Supply and install custom made | set | 21.30 | z007
| | intermediate roller guide cum | | |
| | 75mm(H) x 17mm(L) x 3mm thk | | |
| | mild steel hinge to metal folding door | | |
| | | | |
| D109 | Supply and install 30mm thk hollow | no | 93.00 | SR 2452
| | core timber door to handicap toilet. | | |
| | | | |
| D110 | Supply and fix casement, pivoted or top | m | 1.90 | SR 2453
| | hung window rubber gasket include | | |
| | removal & disposal of existing ensure | | |
| | water tightness. | | |
| | | | |
| D111 | Supply and apply silicone sealant to bind | m | 0.30 | z015
| | aluminium plate to timber door (For gap | | |
| | not exceeding 7.5mm3) | | |
| | | | |
| D112 | Supply and install 850(ht) x 530 (width) | no | 92.00 | z029
| | x 19mm thk timber laminated cupboard door | | |
| | to with 2 nos of stainless steel hinges to | | |
| | match existing. | | |
| | | | |
| D113 | Supply and install new cubicle door | no | 102.90 | z032
| | with formica finish size 600 x 1800 | | |
| | including labour for taking down | | |
| | existing cubicle door | | |
| | (to re-use existing ironmongery). | | |
| | | | |
| D114 | Supply and install 'Posse C111AZ-85mm' | no | 66.40 | Z033
| | entrance knobset. | | |
| | | | |
| D115 | Supply and install 38mm padlock | no | 5.50 | Z008
| | | | |
| D116 | Supply and install cam lock for | no | 6.70 | z025
| | staircase common power point metal | | |
| | housing. | | |
| | | | |
| D117 | Supply and install buckle for securing | no | 3.40 | z027
| | bars. | | |
| | | | |

PAGE 102 OF 104


SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SUPPLEMENTARY SCHEDULE OF RATES (CONT'D) | | |
| | | | |
| D118 | Supply and install CP sink tap. | no | 24.70 | z028
| | | | |
| D119 | Supply and install 'Poly' Model : FV7070 | no | 65.00 | Z010
| | flush valve, 4.5 litres syphon for flushing | | |
| | cistern. | | |
| | | | |
| D120 | Supply and install 1/2" adjustable | no | 40.00 | Z011
| | anti-siphon cistern fill valve as ball | | |
| | valve for flushing cistern. | | |
| | | | |
| D121 | Supply and install "Rigel" solenoid | no | 130.00 | z022
| | valve for W.C. flush valve | | |
| | | | |
| D122 | Supply and fix 25x15mm diameter | no | 3.40 | Z012
| | brass bush for copper pipe | | |
| | | | |
| D123 | Supply and fix 15mm diameter brass | no | 2.60 | z013
| | CFI socket for copper pipe | | |
| | | | |
| D124 | Supply and fix 15mm diameter brass | no | 2.60 | z014
| | CMI union for copper pipe | | |
| | | | |
| D125 | Supply and install 54mm x 54mm | no | 22.60 | z016
| | x 15mm tee (brass) | | |
| | | | |
| D126 | Supply and install 50mm diameter | m | 13.00 | z017
| | galvanised iron pipe. | | |
| | | | |
| D127 | Supply and install 50mm diameter | no | 8.00 | z018
| | galvanised iron socket | | |
| | | | |
| D128 | Supply and install 50mm diameter | no | 11.00 | z019
| | galvanised iron elbow. | | |
| | | | |
| D129 | Supply and install 50 x 25mm diameter | no | 13.00 | z020
| | galvanised iron tee. | | |
| | | | |
| D130 | Supply and install 50mm diameter | no | 4.50 | z021
| | galvanised brackets (for pipeworks). | | |
| | | | |
| D131 | Supply and fix 25mm diameter brass | no | 7.00 | z023
| | nipple for stainless steel pipe | | |
| | | | |
| D132 | Supply and fix 25mm diameter brass | no | 6.20 | z024
| | socket for stainless steel pipe | | |
| | | | |
| D133 | Supply and install 600x600x90mm thick | no | 110.10 | z009
| | medium duty double triangular manhole | | |
| | cover with frame | | |
| | | | |
| D134 | Fill up holes on aeration slabs with | m2 | 1.30 | z026
| | granite fines to prevent stagnation of | | |
| | water | | |

PAGE 103 OF 104


SCHEDULE OF RATES FOR BUILDING WORKS (2006/2008)

| S/N | DESCRIPTION | UNIT | RATE |


| | | | |
| | SUPPLEMENTARY SCHEDULE OF RATES (CONT'D) | | |
| | | | |
| D135 | Supply labour and materials to mobilise | job | 6,667.00 | z030
| | generator on site, dismantle existing | | |
| | collapsed fencing including support angle, | | |
| | barb wire (including erect new fencing | | |
| | with barb wire to match existing) | | |
| | | | |
| D136 | Supply and install 44mm thick | m2 | 132.10 | Z034
| | framed, ledged, braced and batten | | |
| | single leaf door comprising of | | |
| | 100 x 44mm styles and top rail, | | |
| | 150 x 25mm bottom ledge, | | |
| | 100 x 25mm middle ledge and braces | | |
| | filled in with 19mm thk tongued and | | |
| | grooved 'V' jointed boarding (excluding | | |
| | door frame, ironmongeries and painting). | | |
| | | | |
| D137 | Supply and install 44mm thick | m2 | 135.00 | Z035
| | framed, ledged, braced and batten | | |
| | double leaf door comprising of | | |
| | 100 x 44mm styles and top rails, | | |
| | 150 x 25mm bottom rails, 100 x 25mm | | |
| | intermediate rails and braces filled | | |
| | in with 19mm thk tongued and grooved | | |
| | 'V' jointed boarding (excluding door | | |
| | frame, ironmongeries and painting). | | |
| | | | |
| D138 | Supply and Install 50mm thick framed | m2 | 88.50 | Z036
| | lourved double leaf door comprising of | | |
| | 150 x 50mm styles and top rails, 200 x 50mm | | |
| | bottom rails, 150 x 50mm intermediate rails | | |
| | and 19mm thick timber lourves fixed | | |
| | at not more than 19mm apart. | | |
| | (excluding door frame, ironmongeries | | |
| | and painting) | | |
| | | | |
| D139 | Supply and lay average 10mm thick | m2 | 13.40 | SR 2458
| | "Lanko" rapid self leveling screed | | |
| | with 1 coat of "Lanko" acrylic primer. | | |
| | | | |

PAGE 104 OF 104

You might also like