You are on page 1of 8

Analogue Systems

Analogue
Addressable Fire Detection Panels

CF3000
The Cooper Fire CF3000 panel is a high-specification, analogue fire detection panel which is available in
a 1, 2 or 4-loop configuration. It combines sophisticated functionality yet simple operation with a very
aesthetically-pleasing design.

The large capacity, ability to support complex cause and effect programming and wide range of user
controllable functions make the panels suitable for a wide range of projects from sheltered housing to large
office developments as well as many industrial applications.

The panel uses soft addressing to minimize installation time and remove the potential for error associated
with manual addressing.

All of the CF3000 fire detection system components have been specifically designed to operate as part
of an integrated system; this provides an assurance that the panel, sensors, interfaces and other ancillaries
are all fully compatible with each other and that the full range of system functionality is supported by
each device.

• LPCB 3rd party approved to EN54 pts. 2 and 4


• Choice of 1, 2 and 4-loop panel options
• Large multi-functional touch screen
• Spur-tolerant soft addressing
• Short circuit isolators incorporated into each loop device
• Up to 200 addresses per loop
• Fully network capable up to 127 panels
• Network compatible with CF1000 and CF2000 range
of panels
• Optional integral printer

another product from:


CF1000 Range

Analogue addressable
fire detection panels
The Cooper Fire CF1000 range of analogue
fire detection panels are available as a 1 or 2-loop
configured panel.
It provides sophisticated ‘touch screen’ functionality yet
achieves a simple end-user interface operation within a
compact panel design.
The CF1000 panel range supports a complex cause-
and-effect programming ability which, together with a
wide range of user controllable functions, make the panel
suitable for a wide range of projects
Features
As with all Cooper Fire analogue panels the CF1000
• Large versatile touch screen display
range uses ‘spur-tolerant’ soft addressing, thereby • 1 and 2-loop panel versions
minimising installation time and removing the potential • Spur-tolerant soft addressing
for any errors often associated with forms of manual • Short circuit isolators incorporated into every
addressing. loop device
The CF1000 panel loop components have been specifically • Up to 200 addresses per loop
• Network capable with CF3000 and CF2000 range
designed to operate as part of an integrated system;
of panels
this provides an assurance that the panel, sensors,
• Integral power supply
interfaces and other ancillaries are all fully compatible • Large selection of compatible ancillaries
with each other and that the full range of system
functionality is supported by each device.

CF2000

Analogue addressable
fire detection panels
The Cooper Fire CF2000 panel is an entry level two-loop
analogue fire detection panel which can be configured for
1 or 2-loop operation.
The panel has a 126mm x 64mm graphic display
which provides a simple yet comprehensive, menu-driven,
end user interface.
The panel’s ability to support complex cause-and-effect
programming and the wide range of user controllable
functions make the panel suitable for a varied range of
projects from small warehouses to small/medium office
developments as well as many small industrial
applications. Features
As with all Cooper Fire analogue addressable panels, the • BOSEC 3rd party approved to EN54 pts. 2 and 4
CF2000 uses ‘spur-tolerant’ soft addressing to minimize • Choice of 1 or 2-loop panel operation
• Menu-driven graphic screen
installation time and remove the potential for any errors
• Spur-tolerant soft addressing
often associated with forms of manual addressing.
• Short circuit isolators incorporated into each
All of the CF2000 fire detection system components have loop device
been specifically designed to operate as part of an • Up to 200 addresses per loop
integrated system; this provides an assurance that the • Network compatible with CF1000 and CF3000
panel, sensors, interfaces and other ancillaries are all range of panels
fully compatible with each other and that the full range
of system functionality is supported by each device.

another product from:


Analogue Systems

Analogue addressable
fire detection panels
CF3000 and CF1000 Range User Interface Alarm Capacity
- The main element of the user interface is a large - Up to 70 loop-powered sounders, beacons or output
(120mm x 90mm visible area) touch screen display, interfaces per loop
which provides comprehensive user information as well - 3 stages of cause-and-effect programming per
as acting as a multifunctional keypad providing clear output device
and precise user controls and system information
- The panels have four alarm line outputs with
- Comprehensive ‘help’ information is provided throughout a maximum load of 1.5A
the menus to assist end users/system operators
unfamiliar with the panel operation - Additional conventional sounders can be connected
using the loop-mounted alarm line extender unit
- To provide fast, simple text changes within the system,
the touch screen display reconfigures to a full QWERTY Access Modes
keyboard when certain text functions are selected - The Cooper range of analogue panels has 3 modes
(for example, if the change device text menu option of user operation:
is selected) - Normal
- As well as a large format LCD display providing full - End user
system status information, the panel incorporates 96 - Engineer
(CF3000 range) or 16 (CF1000 range) zone indication - End user mode allows access to system test functions,
LEDs to provide information on the status and spread enable and disable menus, view analogue level menus
of any fire, even to a user who is completely unfamiliar and functions such as evacuate, silence alarms and reset
with the system. In addition there are a number of
- Engineer mode allows alteration of system configuration
system status LEDs designed to give clear indication
and programming of site specific data such as device
of the panel and system condition
text and sounder programming. This mode also allows
CF2000 User Interface the adding and removal of devices and alteration of
- The user interface on the CF2000 is a graphic display existing text
which provides comprehensive user information System Functionality
- As well as the graphic display providing full system - The Cooper Fire range of analogue panels are designed
status information, the panel has six ‘push to operate’ to ensure simplicity of future expansion. If an additional
control buttons which provide the various panel device is added after the system has been programmed,
functions. The panel also has 32 traditional zone the panel will allocate the next available address; it will
indication LEDs to provide clear information about the not alter any of the existing address number allocation
status and spread of a fire even to a user who is thus enabling simple updating of as per fitted drawings
completely unfamiliar with the operation of the system. etc. Similarly if a device is removed, the relevant
In addition there are a number of system status LEDs address is saved as a spare address for future use, and
designed to give clear indication of the panel and system the addresses of the remaining devices are not affected
condition
- All devices are soft addressed during commissioning.
Printer (Optional on CF3000 range) However once allocated, addresses are locked until
- Access to printer, when fitted, is via a separate locked manually altered, thus enabling simple system additions
access door. Paper can be changed by non skilled and deletions without affecting other addresses
engineer without exposure to any live components - In the event of an external short-circuit occurring, panel
- The printer can either be set to print on demand or to short circuit isolators on the devices nearest to each side
automatically print all system events as they occur of the short-circuit open, thus isolating the fault yet
maintaining full system integrity
Detection Capacity
- Under short-circuit fault condition, the panel drives
- Up to 200 addresses per loop can be installed, which communication from both ends of the loop thus
can be a mixture of call points, detectors, interfaces or maintaining full communication with all devices
loop sounders. It should be noted that, to comply with
EN54 requirements, no more than 512 addresses should
be connected to a single panel
Analogue addressable
fire detection panels
System Functionality Cont:- Interface Options
- Day/night mode override via timer or external - Zone monitor units can be used to connect zones
switched signal of suitable conventional detectors or loop-powered
- Monitored output to fire routing equipment beam detectors

- Monitored output to fire protection equipment - Sounder circuit controllers can be used to provide
additional conventional sounder circuits without wiring
- Monitored output to fault monitoring equipment back to main panel
- Multiple programmable remote inputs (up to 180 - Mains rated single input / output unit
per panel) can be set for:
- 3-channel, 24V rated, input / output unit
- Override of day/night mode setting
- Photo-thermal sensors go to thermal only - Spur isolator - allows a spur of analogue
- Rate-of-rise sensors go to fixed high addressable devices from loop
temperature mode - Shop unit monitor allows the connection of a
- High temperature heat sensors go conventional detection zone along with 2 conventional
to rate-of-rise mode sounder circuits, ideal for linking small self contained
- Disablement of pre-assigned group units onto a main addressable panel.
of addresses (Requires a 24VDC power supply)
- Class change
Repeater Panel
- Non latching zone input
- Evacuate There are 2 repeater panels available: the CF3000PRG
for loop connection and the CF3000PRGNC for network
connection.
If loop-connected, the panel provides information from the
local panel. If network-connected, the panel provides full
system network information.

Technical Specifications
Panel type CF3000 CF2000 CF1100 CF1200
Standards EN-54:2 1998 & EN54:4 1998 EN-501304
Number of loops CF30001 - 1 loop
CF30002 - 2 loops 2 1 2
CF30004 - 4 loops
Addresses per loop 200
Panel sounder circuits 4 outputs (programmed in pairs - outputs 1&2, 3&4) 2
Class change facility Operated by external, normally open, volt-free contacts
Auxiliary relay One set of change-over contacts, operated in the event of fire activation
Auxiliary fire routing Monitored 24 V DC, 30 mA (max)
equipment output
Auxiliary fire protection Monitored 24 V DC, 30 mA (max)
equipment output
Auxiliary fault routing Monitored 12 V DC, 30 mA (max)
equipment output
Output ports RS485 and RS232
Mains input voltage 230 V AC +10% / -15%
System operating voltage 24 V DC
Battery 2 x 12 V 12Ah 2x 12 V 7Ah 2x12 V 7Ah
Standby duration 24 hours (dependant on loop loading)
Cable entries 31 top-entry cable knockouts 20 top-entry cable knockouts 11 top-entry cable knockouts (20mm)
(20mm) & 12 rear-entry (20mm) & 7 rear-entry plus rear-entry cable aperture
cable knockouts (20mm) cable knockouts (20mm)
Environmental rating IP30, -5ºC to +40ºC, 75% RH (non condensing)
Colour Graphite
Size WxHxD (mm) 395x495x125 400x320x170 375x357x50
Weight 18Kg 15Kg 8Kg

another product from:


Analogue Systems

Application schematics
4 independently-controlled
conventional sounder circuits

Typical Loop Layout

Loops 2-4
if fited

Mains-rated 3 separate inputs 3 independent Mains CSC354


Fire or output relay to accept fire or volt-free Supply
non-fire input contact non-fire inputs output contacts
Repeater

CM10353 C10351
CSI350

Mains
Supply
Mains
Supply

CF3000 CSUM355

CZMU352

2 circuits of Spur of
conventional sounders analogue devices

Zone of compatible
conventional callpoints
and detectors
Network-Connected
Repeater Panel

Zone of compatible
conventional callpoints
and detectors

Repeater Panel
The CF3000PRG repeater panel can be either surface
or semi-flush mounting and provides both system
information and the following system control:
- Silence alarm
Mains Supply - Evacuate
- Reset
Analogue addressable
fire detection panels
Order Codes
1000 Range Description
CF1100 1-Loop panel
CF1100NC 1-Loop panel c/w network card
CF1200 2-Loop panel
CF1200NC 2-Loop panel c/w network card

2000 Range Description


CF2000 2-Loop panel
CF2000NC 2-Loop panel c/w network card

3000 Range Description


CF30001G 1-Loop panel
CF30002G 2-Loop panel
CF30004G 4-Loop panel
CF30001GP 1-Loop panel c/w integral printer
CF30002GP 2-Loop panel c/w integral printer
CF30004GP 4-Loop panel c/w integral printer
CF30001GNC 1-Loop panel c/w network card
CF30002GNC 2-Loop panel c/w network card
CF30004GNC 4-Loop panel c/w network card
CF30001GPNC 1-Loop panel c/w integral printer and network card
CF30002GPNC 2-Loop panel c/w integral printer and network card
CF30004GPNC 4-Loop panel c/w integral printer and network card

Repeater Panels Description


CF3000PRG Loop-mounted repeater
CF3000PRGNC Network-mounted repeater

Ancillaries

Analogue sensors
A comprehensive range of analogue sensors are
available to operate with the Cooper Fire analogue
addressable panel range with the following features:-
• Stylish low profile design
• 360º viewable LED design
• Removable detector chamber
CAP320 – Photoelectric CAPT340 – Photo- CAH330 – Multi-mode
Product Codes smoke sensor thermal smoke sensor heat sensor

CAP320 Optical sensor


CAPT340 Photo thermal ‘Dual’ sensor
CAH330 Heat sensor
CAB300 Analogue sensor base
CIR301 Remote indicator

CAB300 CIR301
Common base Remote indicator

another product from:


Analogue Systems
Ancillaries

The Cooper Fire range of addressable callpoints are


available as surface, flush and weatherproof versions.
All callpoints have integral short circuit isolators and
have a status LED fitted as standard. To simplify
CBG370 CBG370-S CBG370-WP
replacement of glass element, callpoints are fitted with Flush Surface Weatherproof
fast fit, clip-on front covers.
Product Codes
CBG370 Callpoint-flush CXPC Polycarbonate cover (pk of 10)
CBG370-S Callpoint-surface UBSG Spare glass (pk of 5)
CBG370-WP Callpoint-weather resistant CXUK Spare callpoint key (pk of 10)

Base Sounder
The CAS380 is a loop-powered integrated sounder and
sensor mounting base. It can be used with any analogue
sensor or as a standalone sounder with the optional CAS380
CASC cover plate.
Wall Sounder
The CAS381 range of loop-powered addressable wall
sounders offers a highly efficient, low current sounder
option. Sounder volume and tone are set at the analogue
panel avoiding the need to access each sounder CAS381 CAS381-WP
individually to alter settings. Wall sounder Wall sounder IP66

Product Codes
CAS380 Base sounder
CAS381 Addressable wall sounder
CAS381-WP Addressable wall sounder - weatherproof
CASC Pk of 5 base sounder covers

Base Sounder / Beacon


The CASBB384 is a loop-powered, integrated
sounder/beacon and sensor mounting base. It can be used
with any analogue sensor or as a standalone sounder with
the optional CASC cover plate. CASBB384
Sounder beacon base
Wall Sounder Beacons
The Cooper Fire range of loop-powered addressable
wall-mounted sounder beacons offer a highly efficient,
low current sounder beacon option. Sounder volume and
tone are set at the analogue panel avoiding the need to
access each sounder individually to alter settings.
Product Codes CASB383
Sounder beacon
CASB383-WP
IP65 version

CASBB384 Base sounder beacon


CASB383 Wall sounder beacon
CASB383-WP Wall sounder beacon - weatherproof
CASC Pk of 5 base sounder beacon covers
LED Beacon
The CAB382 loop-powered addressable beacon offers high efficiency LED
technology together with a low profile design for a discreet installation.
The beacon is designed to provide a visual indication in areas of high
ambient noise, or where people may be hard of hearing. CAB382
LED beacon
Product Codes
CAB382 LED beacon

Interfaces
An extensive range of interfaces are available
for the Cooper Fire range of analogue panels CSI350 CIO351 CZMU352
providing solutions for most design requirements. Spur isolator unit 3 channel I/O unit Zone monitor unit

COPMIM COPMOM

CMIO353 CSC354 CSUM355 MCIM MCOM


230V relay I/O unit 4 way sounder controller Shop unit monitor Single input module Single output module

Product Codes
CSI350 Spur isolator unit
CIO351 3 channel I/O unit
CZMU352 Zone monitor unit
CMIO353 230V relay I/O unit
CSC354 4 way sounder controller
CSUM355 Shop unit monitor
MCIM Single input module
MCOM Single output module

Please refer to our website for ancillary


technical specifications

Installer Details :

For information on your local stockist contact our


Marketing Department
telephone: 0870 7575 400 fax: +44 (0)1594 545 445
email: marketing@coopersecurity.co.uk
Part No. 11747824

another product from:


www.coopersecurity.co.uk

You might also like