Courier® 6 SL
The high-performance
on-stream XRF
slurry analyzer
The high-power
process management,
Courier® 6 SL
Courier® 6 SL is the high-performance model in the Courier® on- It is complemented by the Courier® 3 SL analyzers for distributed
stream XRF analyzer family for the real-time elemental assaying of applications and remote sampling points. Outokumpu provides
slurry process streams. The high-power analyzer system offers the Customer Support Agreements to guarantee the maximum
best sensitivity and short cycle time for process management, performance and availability of the system.
monitoring and control in all sizes of minerals processing plants.
n S
io
a
m
ct
pl
la
e
ro
C o nt
Ass ay
■ Sampling and analysis are automatically done in the same ■ Assay accuracy is comparable with a high-quality manual sample-
consistent way around the clock. This creates savings in assaying laboratory procedure. Courier® on-stream analyzers use the same
costs and metallurgical sampling. Wavelength Dispersive X-ray fluorescence (WDXRF) analysis
technology as used in high-performance laboratory analyzers.
■ Recoveries are better, as process upsets are detected and solved
rapidly. Frequent assays are necessary for real-time process ■ Results from process tests and changes are readily available, which
monitoring and control. motivates and speeds up process development.
■ Concentrate quality is controllable and undesired variations are ■ Modular Courier® analyzer systems can be upgraded and expanded
minimized. Plant operation is optimized with less circulating loads as plant requirements change.
resulting in higher throughput.
courier_engl 16.4.2003 09:55 Sivu 3
Sampling sample slurry only a short distance, typically less than 1 mm. The
Proven Outokumpu primary samplers are used to sample process sample right at the surface of the analyzer window has to represent
flows. A representative 70–300 l/min primary sample is circulated the whole process flow for accurate on-stream process assays.
through a fast loop to the secondary sampler and back to
a convenient return point in the process. The height loss of the sample Outokumpu-developed Jet Cell™ technology ensures that fresh
is only 1 meter. Primary samples are not mixed with each other. representative sample reaches the critical area for analysis.
A smaller secondary sample is divided out for accurate analysis. The Timeliness of assays
secondary sample stream is sampled by a calibration sampler for The major benefit of using the Courier® on-stream analyzer is the
laboratory assaying during calibration. frequency and speed of accurate assaying. This allows for fast
reaction to changes in the metallurgical behavior of the flotation
When the basic design rules are followed, the primary sample circuit. The cost of frequent laboratory assays required by proper
streams can be used to collect representative composite samples for process control is prohibitive.
metallurgical accounting. Composite sample collection is built into
the Courier® 6 SL sample multiplexers. If the assays are based on strongly filtered or averaged
measurements over a long period of time, the assays cannot be used
Representativity of samples for process control. Long time delay from actual process changes
When considering the representativity of samples used for assaying, to control action makes feedback control unstable and the reported
every step from the process stream to X-ray fluorescence analysis has process trends become misleading.
to be taken into account. X-ray fluorescence radiation penetrates the
courier_engl 16.4.2003 09:55 Sivu 4
Main Rougher
Feed Feed
Cleaner
Primary rougher flotation control Tails
Monitoring the primary rougher concentrate grade is critical for the
production of high-grade concentrate, which can often be added to
the final concentrate.
Concentrate grade is controlled by flotation cell air, level and Scavenger control
reagents. Optimal concentrate grade depends on feed grade, The rougher tails are already under control, so the scavengers just
mineralogy, circulating loads and other circuit parameters. On- lower the final tails assay. Accurate tails assay is important for
stream analysis is vital for optimizing rougher concentrate recovery monitoring and requires high sensitivity and accuracy
production. from the analyzer.
FrothMaster™ froth measurements can be used to complement the The scavenger concentrate assay is watched to keep the circulation
Courier® on-stream analyzer information for optimal rougher control. under control.
courier_engl 16.4.2003 09:55 Sivu 5
Scavenger Flotation
Rougher Tails Tails
Tails Zn Grade Control
Grade High and Recovery Low
Zn_Rougher_Air: +50.00
Zn_Rougher_Level: -10.00
Grade High and Recovery Normal
Scavenger
Grade Normal and Recovery low
Concentrate
Grade Normal and Recovery Normal
ougher Middling Execute fuzzy:
centrate Tails Mass Pull Control
Zn Recovery
Particle size FT FT
density
FC FT LC Cell level
AT Analysis sample points
pH LT
LT Level sensor
FT Flow sensor
LC Level controller
FC Flow controller
pH pH sensor
courier_engl 16.4.2003 09:55 Sivu 6
Primary sampling
The primary sampler directs a part of the process stream to the
multiplexer for secondary sampling. A range of proven
Outokumpu primary samplers is available for various situations.
Analyzer control
The Courier® 6 SL analyzer probe control panel has a graphic
terminal complemented by control switches and indicator lamps.
Most recent assays and analyzer status are shown on the display.
The same cabinet houses interface and control modules for primary
and secondary sampling system monitoring and control.
Demultiplexing
Optional demultiplexing can be used to divert the small slurry
flow through the analyzer flow cell to appropriate point.
Assaying
The Courier® 6 SL analyzer probe combines the high-performance
wavelength and the economic energy dispersive X-ray fluorescence
PSA pressure pipe
methods in a unique and cost-effective way. The analyzer has an primary sampler
for pump outlet
automatic reference measurement for instrument stability and self-
diagnostics. The analyzer probe contains the core analytical
components of the analyzer in a protective IP56 (designed to meet
NEMA 4X) stainless steel enclosure.
Calibration sampling
The built-in calibration sampler helps the operator to take a truly
representative and repeatable sample from the measured slurry for
comparative laboratory assays. The calibration data can be read from
the analyzer into the management station Outocal™ calibration
program.
courier_engl 16.4.2003 09:55 Sivu 7
Secondary sampling
Full primary sample flow is cut by an air-cylinder-actuated Primary
sample in
sample hose. The same cylinder moves the hose to the other
direction across a cutter at programable intervals to collect
a representative composite sample.
1m
The multiplexer operation is designed to minimize the sample Composite
sample
changeover times in large systems. While a sample in one
multiplexer is still being measured, the next sample is already
Primary
being conditioned in the second multiplexer unit, allowing a fast sample return
measurement cycle for all streams.
Secondary
The measurement sequence is fully programable. sample
to analyzer
For example, critical streams can be measured more
frequently and more measurement time can be used for Secondary sampler principle
tailings streams. The switching time between samples is
used for internal reference measurements, which are used for
monitoring and automatic drift compensation. Analyzer management
Courier® 6 SL analyzers can be networked together to share
Composite sample collection of all streams is a standard a common analyzer management station PC. Calibration and
feature of the multiplexer. An optional filter diagnostic data for on-site service requirements and remote
unit dries the composite samples. support.
25 l/min sample
detector
atic digital
om
aut rence multichannel SAMPLING
e
ref ter x-ray tube
t analyzer and
shu
microprocessor
for
filter signal
preamplifier
1mm X-ray SAMPLING
sensitive layer detector
EDXRF channel
PLANT
DCS
SAMPLING
ANALYZER
MANAGEMENT The wavelength dispersive technology. The wavelength dispersive
STATION PC
detection channel measures only the narrow element peak (blue). A high-resolution
spectrometer separates the peak before the detector. Nearby element peaks do not
overlap and background signal is minimal. Because the full capacity of the detector
Main controller
is used for the relevant peak, a high-power X-ray tube can be used and analyzer
speed and sensitivity are high.
Scatter
Energy dispersive
channel EDXRF,
0.12% Zn
counts per second
Specifications
Analysis method Automatic internal reference measurements The analyzer has built-in self- and remote-
Wavelength dispersive X-ray fluorescence compensate for long-term drift. diagnostics capabilities.
method using X-ray tube excitation. Energy
dispersive channels are available. No Minimum detection limit Installation requirements
radioactive isotope sources are used, For most elements in slurry samples, The Courier® 6 SL analyzer can be installed
minimizing fire and disposal risks. detection limit is 3–30 ppm with the on one (low–head) or two levels or in
WDXRF-measurement channel. With the a prefabricated shelter.
Number of sample streams EDXRF-measurement channel minimum
One Courier 6 SL analyzer system can
®
detection limit is typically 30–500 ppm. Flushing water
measure up to 24 sample streams. Each Sand-filtered raw water, 2–6 bar (30–85 psi)
multiplexer module handles up to 6 sample Accuracy average 30 l/min (8 gal/min)
streams. Outokumpu accuracy specification is based peak 100 l/min (26 gal/min)
on measurement of flowing slurry samples
Number of simultaneous assays using measurement times of real Instrument air
Courier 6 SL analyzer can provide up to 12
®
applications. Briquette measurements and Pressure 5–10 bar (75–145 psi)
simultaneous assays for elements from long measurement times give unrealistic 16 Nl/min (4.2 norm. gal/min)
calcium to uranium (atomic numbers 20 to results. Accuracy of measurement is a average consumption
92) and solids content from each process function of the sample parameters such as
sample. Multiple models can be used for matrix composition, mineralization and Power supply
assay calculation. particle size. Single phase AC, 230V +10%, -15% at 10A
50/60 Hz or 115V ±10% at 20A 50/60 Hz.
Sample measurement time Under normal operating conditions, 3–6 % Double conversion 3 kW UPS, 10 minutes
Sample measurement time is selectable for relative standard deviation for minor minimum.
each sample. Typical time is 15–30 seconds. concentrations and 1–4 % relative standard
deviation for major concentrations is Operating ambient temperature
Analysis cycle achieved for individual slurry sample at sea level
Normal analysis cycle for 12 samples is measurements of concentration levels, well +5 – +45°C (41–113°F). Temperature control
from 9–10 minutes and for 18 streams above the minimum detection limit. is based on air-cooled heat exchanger. Water
12–15 minutes, providing on the cooling is available for special conditions.
measuring time for each sample. Analyzer calibration
Assays are calculated and updated from takes a repeatable and representative sample -25 – +60°C (-13 – 140°F)
fresh measured data for each cycle. for the analyzer calibration. Outocal ™
Measurable concentration range calibration model design. Analyzer multiplexers, probe and probe control
Typical measurable concentration range is set, IP56 (designed to meet NEMA 4X).
0.002 % – 100 % by weight for slurries. Maintenance
Stability require minimal maintenance. The analyzer Typical total shipping weight is 1000 kg (2200
Short-term stability of the analyzer under probe window change is automatic, with an lbs) for a 12-stream system, 1250 kg (2750 lbs)
the specified conditions is better than 0.1 % Automatic Window Changer option. for a 18-stream system. One 6-stream multi-
relative. plexer unit weight is 225 kg (500 lbs).
courier_engl 16.4.2003 09:56 Sivu 11
Composite
sampling
Analyzer
Probe Control Probe
2300–3300
Set
PSA
sampler
Process flow
by pressure Demultiplexer
Probe Analyzer
Control Probe
Multiplexer
Several Courier® 6 SL sampling and Composite
sampling
analyzer system features are covered
by patents.
PSA
sampler
Process flow
by pressure
courier_engl 16.4.2003 09:56 Sivu 12
ADASTRA Helsinki
Outokumpu has long and broad experience in the
recovery and refining of base metals. The company has
developed a comprehensive line of metallurgical
processes and related advanced equipment, from grinding
to metal production. Outokumpu TankCell® technology is
used by major mining companies around the world. State-
of-the-art on-stream analyzers and automation systems
have been used in Outokumpu’s concentrators and
refineries since the late 1960’s. The company is the market
and technology leader with more than 700 on-stream
analyzer systems delivered to minerals processing and
metallurgical applications.