You are on page 1of 10

Renewable Pages 15/12/99 9:43 am Page 2

Hawker Batteries
Handbook

STANDBY BATTERIES FOR RENEWABLE ENERGY APPLICATIONS


Renewable Pages 15/12/99 9:43 am Page 4

INTRODUCTION

An increasing awareness of environmental issues has

encouraged the search for alternative sources of energy.

Hawker batteries are widely used in solar power

installations - from communications repeater stations in the

mountains to road-side emergency telephones. High reliability

and low maintenance are essential in remote or un-manned

sites.

Whether you are generating electricity from solar, wind or

water power, Hawker offers the widest choice of technologies

for the most effective solution. Our commitment to innovation

and product design will ensure that batteries continue to play a

vital role in realising the potential of alternative sources of

energy.

1
Renewable Pages 15/12/99 9:43 am Page 5

ESPACE RGTS

APPLICATION INSTALLATION
Espace RGTS has been specifically designed for use in Espace RGTS can be operated either upright or on its
solar and other cyclic renewable-energy applications. side (plates must be in the vertical plane). Ideal for
Based on the highly successful Espace RG design, the cabinets with natural ventilation or in containers
modified grid construction allows frequent cycling with mounted up poles. (nb. Battery life is always reduced in
depth of discharge down to 75% of its C10 capacity. Its raised temperatures)
agm separators and sealed construction remove the
need for cell watering.
FEATURES
6 or 12V configuration
CONSTRUCTION
High Power Density
Positive Electrode Specially modified flat grid with
Excellent cycle life
cyclic alloy (no cadmium)
Tough container resists softening at raised
Negative Electrode Flat grid with lead calcium alloy
temperatures.
Separator Tough agm separator
Long service life
Casing Modified, high impact strength
Proven in solar applications
ABS (flame retardant on
request)
Electrolyte Dilute liquid Sulphuric Acid
Terminal Design Leak-proof compression seal
with brass insert
Connectors Flexible or solid insulated bolt-
on type

Type Voltage Capacity Length Width Height Weight Type Voltage Capacity Length Width Height Weight
C120 to C240 to
1.85 Vpc mm mm mm kg 1.85 Vpc ins ins ins lbs
12 RGTS 47 12 47 218 164 220 18 12 RGTS 47 12 48 8.6 6.5 8.7 39.9
12 RGTS 59 12 59 271 164 220 22 12 RGTS 59 12 60 10.7 6.5 8.7 48.7
12 RGTS 71 12 71 165 165 220 13 12 RGTS 71 12 72 6.5 6.5 8.7 29.1
12 RGTS 85 12 85 360 164 227 31 12 RGTS 85 12 86 14.2 6.5 8.9 67.5

6 RGTS 114 6 114 191 208 236 21 6 RGTS 114 6 117 7.5 8.2 9.3 47.2
6 RGTS 143 6 143 243 206 234 28 6 RGTS 143 6 146 9.6 8.1 9.2 61.5
6 RGTS 181 6 181 196 204 234 34 6 RGTS 181 6 184 11.7 8.0 9.2 75.2
6 RGTS 213 6 213 244 190 276 37 6 RGTS 213 6 217 9.6 7.5 10.9 81.6

C120 Capacity data is calculated at 20°C (68°F) C240 Capacity data is calculated at 25°C (77°F)

2
Renewable Pages 15/12/99 9:43 am Page 6

HAWKER OPzV

APPLICATION INSTALLATION
Hawker OPzV cells are the modern sealed alternative to OPzV can be installed in normal office environments
OPzS. Their proven tubular positive plate design allows provided care is taken to provide natural ventilation.
frequent cycling to extended depths of discharge whilst The cells are designed to be installed on racks.
the gelled electrolyte permits cell mounting to be either
upright or horizontal on racks. There is no requirement
FEATURES
for cell watering as the gases produced during charge
are efficiently re-combined to water inside the cell. Virtually maintenance free
Ideal for frequent deep discharges

CONSTRUCTION 2V configuration

Positive Electrode Tubular design grid with active 200 - 3000Ah range
material encased in tough Long service life
woven gauntlet
Negative Electrode Balanced flat grid negative
ensures good recombination
efficiency
Separator High quality separator ensures
mechanical strength coupled
with fast
acid distribution for improved
power.
Casing Modified, high impact strength
ABS
Electrolyte Dilute Sulphuric acid
immobilised in a silica gel
Terminal Design Leak-proof compression-design
seal and brass insert
Connectors Flexible insulated bolt-on type
Vent Plugs Tamper-proof pressure relief
valve for over-charge protection

Type Voltage Capacity Length Width Height Weight Type Voltage Capacity Length Width Height Weight
C120 to C240 to
1.85 Vpc mm mm mm kg 1.85 Vpc ins ins ins lbs
4 OPzV200 2 254 103 206 403 19.5 4 OPzV200 2 259 4.1 8.1 15.9 43.0
5 OPzV250 2 318 124 206 403 23.5 5 OPzV250 2 323 4.9 8.1 15.9 51.8
6 OPzV300 2 382 145 206 403 28.0 6 OPzV300 2 388 5.7 8.1 15.9 61.7
5 OPzV350 2 460 124 206 520 31.0 5 OPzV350 2 467 4.9 8.1 20.5 68.3
6 OPzV420 2 551 145 206 520 36.5 6 OPzV420 2 560 5.7 8.1 20.5 80.5
7 OPzV490 2 643 166 206 520 42.0 7 OPzV490 2 654 6.5 8.1 20.5 92.6
6 OPzV600 2 835 145 206 695 50.0 6 OPzV600 2 849 5.7 8.1 27.4 110.2
8 OPzV800 2 1114 210 191 695 68.0 8 OPzV800 2 1132 8.3 7.5 27.4 149.9
10 OPzV1000 2 1392 210 233 695 82.0 10 OPzV1000 2 1415 8.3 9.2 27.4 180.8
12 OPzV1200 2 1670 210 275 695 97.0 12 OPzV1200 2 1698 8.3 10.8 27.4 213.8
12 OPzV1500 2 1901 210 275 845 120.0 12 OPzV1500 2 1932 8.3 10.8 32.3 264.6
16 OPzV2000 2 2534 212 397 820 160.0 16 OPzV2000 2 2577 8.3 15.6 32.3 352.7
20 OPzV2500 2 3168 212 487 820 200.0 20 OPzV2500 2 3221 8.3 19.2 32.3 440.9
24 OPzV3000 2 3802 212 578 820 240.0 24 OPzV3000 2 3865 8.3 22.7 32.3 529.1

C120 Capacity data is calculated at 20°C (68°F) C240 Capacity data is calculated at 25°C (77°F)

3
Renewable Pages 15/12/99 9:43 am Page 7

VARTA bloc V - VbV 12121 - VbV 4138

APPLICATION INSTALLATION
VbV is the sealed alternative to the popular Varta-bloc Varta VbV batteries can be installed upright in cabinets
design. It’s rod design positive grid and gelled electrolyte or other closed containers provided allowance is made
make it especially suitable for use in remote cyclic for natural ventilation. This is to allow better heat
applications where maintenance and space are at a dissipation and the removal of any gases produced
premium. during charging (normally negligible). VbV can also be
installed on racks.

CONSTRUCTION
Positive Electrode Rod design grid with lead FEATURES
calcium tin alloy 4V, 6V or 12V configuration
Negative Electrode Grid plate with lead calcium tin Higher Power Density
alloy Modern reliable sealed battery
Separator Microporous (AGM) separator Maintenance free
Casing High impact strength ABS Good cycling ability
Electrolyte Dilute Sulphuric acid Neat container, lid and insulator design
immobilised in a silica gel
Gel electrolyte improves temperature tolerance
Terminal Design Leak - proof Varta safety pole
reinforced with brass insert
(M8)
Connectors Solid copper bolt-on, insulated
cable connectors
Vent Design Safety pressure-relief valve with
flame arrestor

Type Voltage Capacity Length Width Height Weight Type Voltage Capacity Length Width Height Weight
C120 to C240 to
1.85 Vpc mm mm mm kg 1.85 Vpc ins ins ins lbs
VbV12121 12 25 221 176 277 22.8 VbV12121 12 25.6 8.7 6.9 10.9 50.3
VbV12122 12 50 221 176 277 29.5 VbV12122 12 51.2 8.7 6.9 10.9 65.0
VbV12123 12 76 311 176 277 41.1 VbV12123 12 76.9 12.2 6.9 10.9 90.6
VbV12124 12 101 389 176 277 51.9 VbV12124 12 102.5 15.3 6.9 10.9 114.4
VbV12125 12 126 469 176 277 63.9 VbV12125 12 128.1 18.5 6.9 10.9 140.9
VbV12126 12 151 553 176 277 74.2 VbV12126 12 153.7 21.8 6.9 10.9 163.6

VbV6134 6 173 284 229 332 49.6 VbV6134 6 175.7 11.2 9.0 13.1 109.3
VbV6135 6 216 284 229 332 55.1 VbV6135 6 219.6 11.2 9.0 13.1 121.5
VbV6136 6 259 284 229 332 60.7 VbV6136 6 263.5 11.2 9.0 13.1 133.8

VbV4137 4 302 249 229 332 48.8 VbV4137 4 307.4 9.8 9.0 13.1 107.6
VbV4138 4 346 249 229 332 52.5 VbV4138 4 351.4 9.8 9.0 13.1 115.7

C120 Capacity data is calculated at 20°C (68°F) C240 Capacity data is calculated at 25°C (77°F)

4
Renewable Pages 15/12/99 9:44 am Page 8

HAWKER XT

APPLICATION INSTALLATION
Hawker XT has been developed from the highly Hawker XT has been designed to be installed easily in
successful Genesis and Cyclon technologies to provide a cabinets. It can be operated in any orientation (except
temperature tolerant cyclic design ideal for use in solar inverted) even in a completely sealed environment
and other renewable energy applications. It’s tough provided the external vent option has been specified.
Noryl container and industry standard footprint also There is no requirement for water addition.
make it an ideal retro-fit into cabinets and containers
where ordinary batteries have failed. For use in raised
temperature environments, XT is available with a heat FEATURES
dissipating metal jacket. 12V configuration in Industry standard JIS footprint
25% Higher Power Density
CONSTRUCTION Flame retardant Noryl container (UL94 V-0)
Positive Electrode Proven Pure Lead-Tin flat plate Optional metal jacket
with unique Hawker production Optional remote venting chimney
technology.
Up to 400 full depth of discharge cycles (C5 rate)
Negative Electrode Pure Lead-Tin alloy flat plate
Long service life
Separator Tough microporous AGM
Excellent charge acceptance
separator
Casing Modified, high impact strength
Noryl (flame retardant to
UL94 V-0)
Electrolyte Dilute Sulphuric acid captured
in the separator
Terminal Design Leak-proof compression-design
seal and brass insert
Connectors Fexible or solid insulated bolt-
on type
Vent Plugs Safety plug with flame arrestor

Type Voltage Capacity Length Width Height Weight Type Voltage Capacity Length Width Height Weight
C120 to C240 to
1.85 Vpc mm mm mm kg 1.85 Vpc ins ins ins lbs
XT13 12 16.8 176 83 130 4.9 XT13 12 17.0 6.9 3.3 5.1 10.8
XT16 12 21.6 181 76 168 6.4 XT16 12 22.1 7.1 3.0 6.6 14.1
XT30 12 36.0 167 175 126 10.6 XT30 12 36.0 6.6 6.9 5.0 23.4
XT35 12 42.0 197 166 144 13.4 XT35 12 42.0 7.8 6.5 5.7 29.5
XT40 12 48.0 198 166 171 16.1 XT40 12 48.0 7.8 6.5 6.7 35.5
XT70 12 81.6 331 168 176 25.7 XT70 12 81.6 13.0 6.6 6.9 56.7
C120 Capacity data is calculated at 20°C (68°F) C240 Capacity data is calculated at 25°C (77°F)

5
Renewable Pages 15/12/99 9:44 am Page 9

HAWKER OPzS

APPLICATION INSTALLATION
Hawker OPzS cells are proven to be reliable in cyclic OPzS cells are normally installed in a purpose-built
applications. Their classic tubular positive plate design battery room . The cells are designed to be installed
allows frequent cycling to extended depths of discharge upright on racks.
whilst the free electrolyte permits continued use in the
raised temperature environments of a solar system. Cell
FEATURES
watering is reduced to a minimum through the careful
choice of positive plate alloy. The transparent containers Low maintenance (2-3 year watering interval)
allow easy checking of electrolyte levels. Ideal for frequent deep discharges
2V configuration
CONSTRUCTION 200 - 3000Ah range
Positive Electrode Tubular design grid with active Long service life (up to 15 years)
material encased in tough
woven gauntlet
Negative Electrode Balanced flat grid negative
ensures minimum maintenance
Separator High quality separator ensures
mechanical strength coupled
with fast acid distribution for
improved power.
Casing High impact strength SAN
Electrolyte Dilute Sulphuric acid
Terminal Design Leak-proof compression-design
seal and brass insert
Connectors Flexible insulated bolt-on type
Vent Plugs Splash-proof, flame arresting
vent plugs for safe operation.

Type Voltage Capacity Length Width Height Weight Type Voltage Capacity Length Width Height Weight
C120 to C240 to
1.85 Vpc mm mm mm kg 1.85 Vpc ins ins ins lbs
4 OPzS200 2 300 103 206 405 17.2 4 OPzS200 2 312 4.1 8.1 15.3 37.9
5 OPzS250 2 375 124 206 405 20.8 5 OPzS250 2 390 4.9 8.1 15.3 45.9
6 OPzS300 2 450 145 206 405 24.3 6 OPzS300 2 468 5.7 8.1 15.3 53.6
5 OPzS350 2 525 124 206 520 26.9 5 OPzS350 2 546 4.9 8.1 20.0 59.3
6 OPzS420 2 630 145 206 520 31.5 6 OPzS420 2 655 5.7 8.1 20.0 69.4
7 OPzS490 2 735 166 206 520 36.1 7 OPzS490 2 764 6.5 8.1 20.0 79.6
6 OPzS600 2 900 145 206 695 44.8 6 OPzS600 2 936 5.7 8.1 27.1 98.8
8 OPzS800 2 1200 210 191 695 61.3 8 OPzS800 2 1248 8.3 7.5 27.1 135.1
10 OPzS1000 2 1500 210 233 695 74.6 10 OPzS1000 2 1560 8.3 9.2 27.1 164.5
12 OPzS1200 2 1800 210 275 695 88.0 12 OPzS1200 2 1872 8.3 10.8 27.1 194.0
12 OPzS1500 2 2250 210 275 845 114.3 12 OPzS1500 2 2340 8.3 10.8 32.6 252.0
15 OPzS1875 2 2775 212 397 820 145.0 15 OPzS1875 2 2925 8.3 15.6 33.0 319.7
16 OPzS2000 2 3000 212 397 820 152.0 16 OPzS2000 2 3120 8.3 15.6 32.0 335.1
20 OPzS2500 2 3750 212 487 820 190.0 20 OPzS2500 2 3900 8.3 19.2 32.0 418.9
24 OPzS3000 2 4500 212 576 820 225.0 24 OPzS3000 2 4680 8.3 22.7 32.0 496.0

C120 Capacity data is calculated at 20°C (68°F) C240 Capacity data is calculated at 25°C (77°F)

6
Renewable Pages 15/12/99 9:44 am Page 10

VARTA bloc - Vb 12101 - Vb 4118

APPLICATION INSTALLATION
High tolerance to cycling, low losses from self discharge, Varta bloc batteries are designed to be mounted on racks
high charging efficiency and long maintenance intervals in purpose built battery rooms but their higher energy
make Varta-bloc batteries especially suitable for solar density and monobloc design help to reduce the space
and wind power systems. required. The attractive modern design and transparent
containers keep maintenance to a minimum.

CONSTRUCTION
Positive Electrode Lead selenium, rod plate FEATURES
wrapped in a fleece pocket. 2V, 4V, 6V or 12V configuration
Negative Electrode Grid plate with fibre reinforced Higher Power Density
paste Modern, reliable cycling battery
Casing High impact strength Very low maintenance requirement (up to 5 year
transparent ABS (monoblocs) or interval)
SAN (single cells)
Good cycling ability
Electrolyte Dilute Sulphuric acid
Neat container, lid and insulator design
Terminal Design Leak - proof Varta safety pole
reinforced with brass insert
Connectors Solid copper bolt-on, insulated
cable connectors
Vent Design Safety plug with flame arrestor
(concealed on monobloc design)

Type Voltage Capacity Length Width Height Weight Type Voltage Capacity Length Width Height Weight
C120 to C240 to
1.85 Vpc mm mm mm kg 1.85 Vpc ins ins ins lbs
Vb12101 12 26.5 221 176 277 23.1 Vb12101 12 28 8.7 6.9 10.9 50.9
Vb12102 12 53.0 221 176 277 24.4 Vb12102 12 56 8.7 6.9 10.9 53.8
Vb12103 12 79.5 311 176 277 34.5 Vb12103 12 84 12.2 6.9 10.9 76.1
Vb12104 12 106.0 389 176 277 43.8 Vb12104 12 112 15.3 6.9 10.9 96.6
Vb12105 12 133.0 469 176 277 53.3 Vb12105 12 140 18.5 6.9 10.9 117.5
Vb12106 12 159.0 553 176 277 63.0 Vb12106 12 168 21.8 6.9 10.9 138.9

Vb6114 6 188.0 284 229 332 42.8 Vb6114 6 196 11.2 9.0 13.1 94.4
Vb6115 6 235.0 284 229 332 47.0 Vb6115 6 245 11.2 9.0 13.1 103.6
Vb6116 6 282.0 284 229 332 51.3 Vb6116 6 294 11.2 9.0 13.1 113.1

Vb4117 4 329.0 249 229 332 41.3 Vb4117 4 343 9.8 9.0 13.1 91.0
Vb4118 4 376.0 249 229 332 44.3 Vb4118 4 392 9.8 9.0 13.1 97.7

C120 Capacity data is calculated at 20°C (68°F) C240 Capacity data is calculated at 25°C (77°F)

7
Renewable Pages 15/12/99 9:44 am Page 11

VARTA GLS Plus

APPLICATION INSTALLATION
VARTA vented tubular-plate monoblocs type GLS Plus The blocs are suitable for mounting on racks and
are suitable for all standby applications which require a delivered with flame arresting vent plugs and integral
high tolerance to cycling and long float life. The product handles.
uses proven and reliable low antimony tubular design
plates in a flooded electrolyte and is used in varied
FEATURES
applications.
6 sizes available
Very durable, proven technology
CONSTRUCTION Excellent cycling tolerance
Positive Electrode Low antimonial tubular Low water consumption
Negative Electrode Flat pasted plate High conductivity terminals

Separation Tough microporous separator Clear container for easy maintenance

Casing Material Transparent styrene-acrylo-


nitrile (SAN)
Electrolyte High purity dilute sulphuric acid
1.240 density at 20°C
Terminal Design Lead with copper insert
Charging Float charge voltage:
2.23V per cell at 20°C (68°F)

Type Voltage Capacity Length Width Height Weight Type Voltage Capacity Length Width Height Weight
C120 to C240 to
1.85 Vpc mm mm mm kg 1.85 Vpc ins ins ins lbs
12/60 12 0.65 272 205 380 34.8 12/60 12 0.33 10.7 8.1 15.0 76.7
12/100 12 1.18 272 205 380 44.4 12/100 12 0.61 10.7 8.1 15.0 97.9
12/150 12 1.77 380 205 380 63.6 12/150 12 0.92 15.0 8.1 15.0 140.2

6/210 6 2.36 272 205 380 43.3 6/210 6 1.23 10.7 8.1 15.0 95.5
6/270 6 3.12 380 205 380 57.0 6/270 6 1.62 10.7 8.1 15.0 125.7
6/310 6 3.54 380 205 380 62.2 6/310 6 1.84 15.0 8.1 15.0 137.1
C120 Capacity data is calculated at 20°C (68°F) C240 Capacity data is calculated at 25°C (77°F)

8
Renewable Pages 15/12/99 9:43 am Page 1

Hawker Group
PO Box 227
Avon House
The Westinghouse Site
Chippenham
Wiltshire SN15 1SJ
Tel: +44 1249 442 551
Fax: +44 1249 442 550
www.hawker-batteries.com

An Invensys Company Hawker/RE/1/July99