You are on page 1of 21

THE APPLICATION AND

PERFORMANCE OF
MEM-X

Dr Jens Nähring – Genesys Deutschland


Visit www.genesysro.de
MEM-X

MEM-X IS EFFECTIVE AGAINST:-


• ALUMINIUM, IRON, MANGANESE
• OXIDES AMD HYDROXIDES
• INORGANIC SCALE
• GENERAL ORGANICS

IT HAS BEEN USED EFFECTIVELY AGAINST


PERSISTENT FOULANTS WHEN ALL OTHER
PRODUCTS HAVE FAILED! Visit www.genesysro.de
MEM-X
TYPICAL FOULANT ANALYSIS UF MEMBRANE

3%
27%
35%

8%
5%
22%
Aluminium Aluminosilicates Biofilm
Calcium Phospate No deposits detected Organic Matter

Visit www.genesysro.de
MEM-X

• HAS GOOD REPUTATION IN MARKET


ALREADY TESTED SUCCESSFULLY WITH:-
DOWTM UF
HYDRANAUTICS UF HYDRACAP
INGE
ZENON
NORIT X-FLOW
MICRODYNE-NADIR
Visit www.genesysro.de
Case 1: Iron fouling+silt removed

3% Mem-X,

48h soak

Recovered

DOW UF

Membranes
Case 2: Brownish foulant Fe-Mn
1.2% Mem-X, 10h: clean & white
Comparison at x100

View of inside of membrane

Before cleaning After cleaning


Comparison at x500

View of inside of membrane

Before cleaning After cleaning


Comparison at x100

View of inside of membrane

Before cleaning After cleaning


Commodities NaOH and HNO3

NaOH – caustic soda HNO3 – nitric acid


unsuccessful unsuccessful
1.NaOH 2.HNO3 or Mem-X

Norit X-Flow
Case 3: Removal of yeast

1 2 1. Before cleaning

2. Mem-X plus
Genesol 703
followed by
Mem-X
Case 4: Removal of Iron
+ activated carbon

4cm of fibre
before
cleaning

Same fibre
after
cleaning

For ease of viewing the fibres have been sectioned after cleaning.
Case 4: Removal of Iron
+activated carbon

Soaking of a
whole fibre.

On rinsing, the carbon


is flushed out.
Top,

middle

& bottom view


of sectioned fibre.
Some citations of users

Abdelkader GAID
• Les premiers résultats de nettoyage de la
membrane UF hydranautics contenant du
CAP semblent satisfaisants par rapport
aux nettoyages chimiques utilisés jusqu’à
présent.
Case 5: X-Flow
KA Merklingen
Druck nach Membran [bar]
Druck UF 2
Druck vor Membran [bar]
vom 16.10.2006 12:00:00 TMP 2 [bar]
bis 17.10.2006 16:00:00
Druck vor Membran [bar]
Druck nach Membran [bar]

TMP 2 [bar]

2,0456
Beschreibung Wert
1,9456 Druck nach Membran
1,8456 Druck vor Membran
TMP 2
1,7456

1,6456

1,5456

1,4456

1,3456

1,2456

1,1456 Transmembrane
1,0456

0,9456
pressure before
0,8456 cleaning
0,7456

0,6456

0,5456

0,4456

0,3456

0,2456

0,1456

0,0456
16.Okt 12:00 16.Okt 18:00 17.Okt 0:00 17.Okt 6:00 17.Okt 12:00
Case 5: X-Flow
KA Merklingen
Druck nach Membran [bar]
Druck UF 2
Druck vor Membran [bar]
vom 18.10.2006 12:36:50 TMP 2 [bar]
bis 19.10.2006 12:36:49
Druck vor Membran [bar]
Druck nach Membran [bar]

TMP 2 [bar]

2,000
Beschreibung Wert
1,900
Druck nach Membran
1,800 Druck vor Membran
TMP 2
1,700

1,600

1,500

1,400

1,300

1,200

1,100

1,000

0,900

0,800
Transmembrane
0,700

0,600 pressure after


0,500 cleaning
0,400

0,300

0,200

0,100

0,000
12:00 14:00 16:00 18:00 20:00 22:00 0:00 2:00 4:00 6:00 8:00 10:00 12:00

Gedruckt am: 19.10.2006 12:36:56 von Gerhard Fink


MEM-X
GENESOL 703 MEM-X

ORGANICS X X

CLAYS
X X X

METALS X X X

PARTICULATES X X X

ACTIVATED CARBON
X X X

Visit www.genesysro.com
MEM-X

•POWDERED PRODUCT

•EASY TO MANIPULATE

•LOW DOSAGE 1-2%

•BLEND OF ALKALINE

Visit www.genesysro.de
THANK YOU

Visit www.genesysro.de

You might also like