You are on page 1of 2

Chandler Dew Point Testers

Bureau of Mines-Type Dew Point Tester from AMETEK

BUREAU OF MINES MODEL


The Chandler Bureau of Mines Dew Point Tester is a primary
instrument used to measure the dew point temperature of any
gas. It is rugged, portable, and can provide very repeatable
results. Because of its primary nature, the standard dew point
tester requires no calibration. Consequently, it is frequently used
to verify results of electronic instruments.

The Chandler Dew Point Tester is a chilled mirror device that


operates by achieving the conditions required by the definition
of dew point. When a gas is cooled out of contact with liquid
water, the humidity or water content remains constant, but the
percentage of saturation increases until it reaches 100% and
moisture begins to condense. The temperature at this point is
known as the dew point or frost point.

OPERATION
Chanscope II Digital Dew Point Tester
The Chandler “Bureau of Mines-type”
Dew Point Tester consists of a small
high pressure chamber through which APPLICATIONS
the gas sample flows. A polished
mirror is at one end of the chamber Natural Gas
and a viewing window at the other. Designed for accuracy in the rugged
The operator controls an expandable environment typically found in the gas
gas through a valve, cooling the industry. A special model is available for
polished mirror until the dew point is offshore use.
observed. The temperature and
Standard Dew Point Tester Sour Gas
pressure are then recorded and
plotted on a graph to obtain the water content of the sample. Hydro- Corrosion-resistant materials are used for
carbon dew points in natural gas can be obtained using the same H2S atmospheres.
method.
Industrial Gases
FEATURES The tester is ideally suited for the mea-
surement of the dew point of pressurized
Meets ASTM D1142. N2, O2, H2, Ar, air, and other bottled
Portable and rugged for repeatable results. gases.
Nothing to calibrate.
Heat Treating Furnaces
Traceable to NIST.
Chandler instruments are easy to use and
Easy to maintain and use. produce reliable, accurate answers. They
have been used for years in this applica-
tion.
SPECIFICATIONS
Chanscope II Dew Point Tester Standard Dew Point Tester
Accuracy: ±0.1°C (0.2°F) down to 0°C (32°F) Accuracy: ± -0.5°F (± 0.25°C)
±0.5°C (1.0°F) down to -100°C (-148°F) Dew Point Dependant on which thermometer is
±1.0°C (2.0°F) down to -200°C (-328°F) Temperature Range: chosen.
Dew Point Operating Pressure: Up to 5000 psig (34.6 MPa)
Temperature Range: -200°C (-148°F) to ambient
Connections: Sample inlet and outlet: 1/8” NPT;
Operating Pressure: Up to 5000 psig (34.6 MPa) Refrigerant, 1/8” tube
Connections: Sample inlet and outlet: 1/8” NPT; Ship Weight: 25 lb (11 kg)
Refrigerant, 1/8” tube
Carrying Case: 14” x 18” x 7” (35.5cm x 20cm x 17.8cm)
Power: Battery-powered with 115VAC or 230VAC
charger.
Ship Weight: 25 lb (11 kg)
Carrying Case: 14” x 18” x 7” (35.5cm x 20cm x 17.8cm)

OPTIONS ACCESSORIES
Digital Readout Glycol Filter (13-0054)
The Chanscope II version allows lighted, magnified viewing For the removal of glycol vapors from gas stream being
of the dew point with a digital temperature display superim- tested. Especially useful when glycol temperature is above
posed on the viewing window in tenths of degree. The unit water dew point. Can be supplied as original equipment or
also has a button-hold feature to retain the measured value. added later.
The model uses accurate platinum RTD and LED readout
to give the operator instantaneous feedback during a test. Tripod (P-0535)
Special lightweight and rigid, all aluminum construction.
Pressure Range Two-section legs; extended height 54.5” (1380mm). Used
Models are available in ranges of 1,000, 3,000 or 5,000 to support Dew Point Tester.
psig (7.0, 20.8, and 34.6 MPa).
Propane-Type Cylinder (P-0536)
Regular Chiller 20 lb ICC cylinder supplied with delivery control valve and
Uses liquid propane: -29°C (-20°F) or liquid carbon dioxide fittings. Male 1/4” NPT connection. Cylinder shipped empty.
-62°C (-80°F) as a refrigerant. Its geometry optimizes
thermal uniformity for superior control and accurate Cubic-Foot Siphon Tube Bottle (13-0277)
determination. Filled with liquid CO2 refrigerant gas, complete with valve
and fittings. Male 1/4” NPT connection.
Quick Chiller
Uses the same expandable gases but directs them onto the Illuminated Magnifiers
back of the polished mirror. Fast reaction time is achieved, 1,000 psi (7MPa) 13-0303; 3,000 psi (20.8 MPa) 13-0304;
but there is an increased risk of overshooting the dew point Replacement Illuminator Assembly 13-0305
until all components reach thermal equilibrium. Improved mirror lighting using a 4-power, prefocused,
battery-operated device. Illuminates and clarifies the “dew
Liquid Nitrogen Chiller
spot” of the Standard Dew Point Tester. Ensures optimum
Uses an immersion rod and Dewar flask containing N2 for accuracy of dew point determination regardless of field
temperatures down to -129°C (-200°F). lighting conditions.
Thermometers
A wide range of thermometers are available in Centigrade
All Dew Point Testers are furnished with:
or Fahrenheit , including certified thermometers traceable
to NIST. Thermometers are filled with a biodegradable Spare O-rings
liquid, eliminating the safety concerns of mercury. (Sour Gas model, spare Kalrez O-rings optional.)
10 ft stainless steel sample tubing with SS fitting.
10 ft stainless steel tubing with SS fittings for
refrigerant gas.
Carrying case
Manual

One of a family of innovative process analyzer solutions from AMETEK Process Instruments. Specifications subject to change without notice.

USA - Pennsylvania USA - Delaware SUPPORT FRANCE


150 Freeport Road 455 Corporate Blvd. LOCATIONS Ph. 33 1 30 68 69 20
Pittsburgh, PA 15238 Newark, DE 19702 Fax 33 1 30 68 69 29
Ph. 412-828-9040 MANUFACTURING Ph. 302-456-4400
Fax 412-826-0399 Fax 302-456-4444 USA - Texas GERMANY
LOCATIONS Ph. 281-463-2820
.ametekpi.com
www.ametekpi.com
www Ph. 49 21 59 91 36 0
Fax 281-463-2701 Fax 49 21 59 91 3680
© 2004, by AMETEK, Inc. All rights reserved.
CANADA USA - Oklahoma Dewpoint (09/04) CHINA - Beijing
2876 Sunridge Way N.E 2001 N. Indianwood Ave. MIDDLE EAST - Dubai
Ph. 86-10-85262111 Ph. 971-4-881 2052
Calgary, AB T1Y 7H9 Broken Arrow, OK 74012 Fax 86-10-85262141
Ph. 403-235-8400 Ph. 918-250-7200 Fax 971-4-881 2053
Fax 403-248-3550 Fax 918-459-0165 CHINA - Shanghai SINGAPORE
Ph. 86 21 6426 7049 Ph.65-6484-2388
Fax 86 21 6426 7054 Fax 65-6481-6588

You might also like