IXYS reserves the right to change limits, test conditions and dimensions
200 1000
TVJ = 125°C
40
TVJ = 125°C
TVJ = 125°C 100
20
TVJ = 25°C
0 0 500
0.0 0.5 1.0 1.5 V 2.0 0.001 0.01 0.1 s 1 1 2 3 4 5 6 7 ms
8 910
VT t t
Fig. 3 Forward characteristics Fig. 4 Surge overload current Fig. 5 I2t versus time (1-10 ms)
ITSM: crest value, t: duration
140 80
W A
DC
120 RthKA : IT(AV)M70 180° sin
PT 120°
0.1 K/W 60°
60
100 30°
0.5 K/W
1 K/W 50
80 2 K/W
4 K/W 40
10 K/W
60
30
DC
40
180° sin 20
120°
20 60°
30° 10
0 0
0 10 20 30 40 50 60 70 A 0 25 50 75 100 125 °C 150 0 20 40 60 80 100 120 °C
IT(AV)M Tamb Tcase
Fig. 6 Power dissipation versus forward current and ambient temperature Fig. 7 Max. forward current at case
temperature
1.0
RthJC for various conduction angles d:
K/W
30° d RthJC (K/W)
ZthJC 60°
120° DC 0.62
180° 180° 0.71
DC 120° 0.748
60° 0.793
0.5 30° 0.817