You are on page 1of 6

INSTRUCTION SHEET IS-TY2821

6 CORPORATE PARKWAY
GOOSE CREEK , SC . 29445 STYLE NUMBER: TY2821AN, TY2821WT
www . quoizel . com

PACKAGE CONTENTS ISSUED 07-2010 REVISED 2011-01-27

PART DESCRIPTION QUANTITY


P
A Crossbar 1 pc
B Green Ground Screw 1 pc A

C Mounting Screw 2 pcs


D Lock Washer 2 pcs B
E Small Hex Nut 2 pcs
F Mounting Ball 2 pcs C
G Lock Screw 3 pcs
H 1/8IP Hex Nut 1 pc
D
Flat Washer 2 pcs Q
I E
J Rubber Washer 2 pcs R
F
K Cap 1 pc S
G
L 6” Rod 2 pcs
H
T
M 12” Rod 2 pcs
I
N Ring 1 pc U

O Shade 1 pc V
J
P Ceiling Canopy 1 pc
Q Finial A 3 pcs W
K
R Check Ring 1 pc
L
S Finial B 1 pc
M
T Center Column 1 pc
N
U Side Arm 3 pcs
V Center Stem 1 pc
O
W Spacer Tube 1 pc

WARNINGS AND CAUTIONS


WARNING:
● Before beginning the installation, turn off electricity at the circuit breaker box or the main fuse box by switching
off the circuit breaker or removing the fuse.
CAUTION:
● These instructions are provided for your safety. It is very important that they are read completely before the
installation of your fixture. We strongly recommend that a professional electrician install the fixture.
● Disconnect fixture from the power source before replacing the bulb(s), making sure that bulb(s) had sufficient
time to cool down. DO NOT subject the lamp to any shock while lit as shattering of lamp may result.

1 OF 6
PREPARATION STYLE NUMBER: TY2821AN, TY2821WT

● Before beginning installation of product, make sure all parts are present. Compare parts with package contents
list and diagram above. If any part is missing or damaged, do not attempt to assemble, install or operate the
product. Contact customer service for replacement part.
● Estimated Assembly Time: 30 - 45 minutes
● Tool Required for Assembly (not included): Flathead screwdriver, Phillips screwdriver, Pliers, Electrical tape,
Wire cutter, Safety glasses and (4) 100W Type-A medium base bulbs .
● Helpful Tools (not included): Wire strippers.

INSTALLATION INSTRUCTIONS

STEP 1: DETAIL A
a. (Refer to DETAIL A) Place the hole on the top end of the
Side Arm over the Pipe at the side of the Center Finial A
Column. Thread the Finial A onto the end of the Pipe to
secure the Side Arm.
b. (Refer to DETAIL B) Attach the Connectors on the Ring
to the bottom of the Side Arms. Line up mounting holes
Side Arm
on the Connectors and holes on the Side Arms. Using
screwdriver, thread Lock Screws into the mounting
holes on the Connectors to secure them together. Pipe
Hand-tighten until snug.

Finial A

Side Arm

Center Column
Lock Screw

Connector

Ring

Lock Screw

Side Arm

Ring

DETAIL B Connector

2 OF 6
INSTALLATION INSTRUCTIONS STYLE NUMBER: TY2821AN, TY2821WT

STEP 2:
a. Determine the Rods to be assembled according to your
desired hanging height.
6” Rod
b. Pass the Supply Wires with Ground Wire through the
chosen Rods and then thread Rods and Center Column 6” Rod
together as shown. Hand-tighten until snug.

12” Rod

12” Rod

Coupling Supply Wires with


Ground Wire

Center Column

STEP 3:
a. Pass the Supply Wires with Ground Wire through the
Ceiling Canopy
Swivel and Ceiling Canopy.
b. Thread the Swivel onto the top end of the Upper Rod.
Hand-tighten until snug.
Swivel

Supply Wire with


Ground Wire

Upper Rod

3 OF 6
INSTALLATION INSTRUCTIONS STYLE NUMBER: TY2821AN, TY2821WT

STEP 4: Mounting Screw


a. Screw the Mounting Screws into the Crossbar , place Crossbar
the Lock Washers over the Mounting Screws and Hex Nut
thread the Hex Nuts onto the Mounting Screws as
shown . Secure the position of the Mounting Screws by
tightening the Hex Nuts against the Crossbar .
b. Secure the Crossbar to the Outlet Box with Outlet Box
Screws . Lock Washer

Outlet Box
Outlet Box Screw

STEP 5:
a. Locate the Ceiling Canopy onto the Crossbar and slip
the Button Stop on the end of Lanyard into the Slot on Crossbar
the Crossbar as shown.
Slot
Button Stop
Lanyard

Ceiling Canopy

STEP 6:
Use Wire Connectors (not supplied) to connect the
WHITE OR RIBBED WHITE OR RIBBED
wires.
a. Connect the House Ground Wire to the Fixture Ground FROM HOUSE FROM FIXTURE
Wire.
b. Connect the House White (or Ribbed) Wire to the
Fixture Supply Wire (Black or Smooth Side). BLACK (OR RED) WIRE BLACK OR SMOOTH
c. Connect the House Black (or Red) Wire to the Fixture FROM FIXTURE
FROM HOUSE
Supply Wire (Black or Smooth Side).
d. Wrap each connection with approved electrical tape
and carefully stuff all of the connected wires into the GROUND WIRE GROUND WIRE
Outlet Box.
FROM HOUSE FROM FIXTURE

4 OF 6
INSTALLATION INSTRUCTIONS STYLE NUMBER: TY2821AN, TY2821WT

STEP 7:
a. Place the Ceiling Canopy over the Mounting Screws
and secure with the Mounting Balls. Hand-tighten until Outlet Box
snug.
Mounting
Screw
Ceiling
Canopy

Mounting Ball

STEP 8:
a. Screw the beaded end of the Center Stem into the Hex
Coupling underside of the Junction Box. Hand-tighten
until snug.

Hex Coupling
Junction Box
Center Stem

STEP 9:
a. Place the Spacer Tube, the Check Ring, the Flat
Washers, the Rubber Washers and the Shade over the
end of the Center Stem as shown. Secure them by
threading the 1/8 IP Hex Nut onto the Center Stem.
Hand-tighten until snug.
Center Stem

Spacer Tube

Check Ring
Shade Flat Washer
Rubber Washer

Rubber Washer
Flat Washer
1/8 IP Hex Nut

5 OF 6
INSTALLATION INSTRUCTIONS STYLE NUMBER: TY2821AN, TY2821WT

STEP 10:
a. Place the Cap over the end of the Center Stem and
secure with the Finial B. Hand-tighten until snug.

Center Stem

Cap

Finial B

STEP 11:
a. Install correct bulbs referring to fixture markings and/or labels for maximum wattage.

Your installation is completed now. Restore electricity. Retain this sheet for future reference.

6 OF 6

You might also like