You are on page 1of 7

SURVEYS FOR

MAINTENANCE OF
CLASS

Ref: BKI vol I : Rules for Classification and


Surveys

SURVEY FOR MAINT’CE OF CLASS


1. PERIODICAL 2. NON PERIODICAL
SURVEY SURVEYS
A. Annual Surveys A. Damage and Repair
B. Intermediate Surveys Surveys
C. Class renewal Surveys B. Voyage Repair and
D. Periodical Surveys of Maintenance Surveys
Individual Propulsion & C. Conversion Surveys
Steering Systems D. Occasoinal Surveys
E. Periodical Surveys of
Individual Machinery
Items
F. Drydocking Surveys
G. In-water Surveys

1
1.A. ANNUAL SURVEY
 For seagoing ships, including:
– hull,
– anchoring eqpmt,
– machinery, electrical plant,
– special eqpmt classed
 Interval: 12 months
 Survey Period: 3 months (counted from the
current class will complete 1 year of validity)
 On drydocking (if it is due), or on Ship afloat
 Ship with accomdtn for more 12 passgr survey
must include drydocking survey

1.A. Annual Surveys (HULL)


 Structure: Visual Inspection (as far as accessible)
 Cargo Holds & Engine Room: Random Survey
(acc. to age and condition)
 Hatches, b’hd doors, ramps, bow, side and stern
doors: Surveys acc to tightness and operability
 Steering gear & Anchor eqpmt: Survey for visible
damages
 Ballast tanks: Survey for corrosion damages
(>75% of allowable margins)
 In case suspected damage: surveyor entitled to
carry further investigation

2
1.A. Annual Surveys (MACHINERY)
 Machinery, Boiler Room, Aux Engine, Fire &
Explosive Sources, Emergency exit: General
Inspection
 Boiler & Pressure Vessels (appliances and safety
devices)
 Remote Control, Quick Stopping Devices
 Main & Aux Steering Gear
 Communication Syst: bridges to E/R
 Bilge System
 Main & Emg’cy Power Supply Systems
 Explosion-proof Installations

1.A. Annual Surveys (FIRE SYST)


 Fire mains, incl hose & nozzles
 Gas Fire Extinguishing Syst
 Dry Powder & Foam system
 Sprinkles & other fixed Extinguishing syst
 Portable Extinguishing syst
 Fire Detection & Alarm System
 Emg’cy stops: Ventilation, Boiler, and Fuel Syst
 Fire Closure: Fire dampers, E/R Skylight
 Fireman’s Outfits

3
1.B. INTERMEDIATE SURVEY
 Refered as: Extended annual survey
 Interval: 2.5 yrs after class renewal
 For seagoing ships: on the 2nd or 3rd of
annual survey
 Items to inspect:
– Ballast tank
– Cargo Holds
– Bow visors, Boe sides, and Stern doors
– Elastic mounting of deck houses
– Machinery and Electrical installations

1.B. Intermediate Surveys


(BALLAST TANK)

 For 5 to 10 yrs ships: selected tanks only


 For > 10 yrs ships: all tanks should be
inspc’td
 Corrosion and/or Protective Coating
damages
 Thickness measurement if necessary
 For repair of coating and damage: all
working procedure must be documented

4
1.B. Intermediate Surveys
(CARGO HOLDS)

 Depend on ship’s age ang cargo carried


 Selected cargo holds to be closely
examined
 Ensure the condition of all important
structural elements
 Test and measurement if necessary

1.B. Inter’mdt Surveys (BOW VISOR,


BOW SIDE, & STERN DOORS)
 Structure to be inspected thouroughly and
to be additionally crack tested
 Crack tests will cover:
– Main joining welds
– Center of rotation of the hinges
– Locking devices and stoppers
– Repair welding
 Test methods: Dye penetrant or
Magnaflux

5
1.B. Inter’mdt Surveys (MACHINERY
AND ELECTRICAL INSTALL’TN)
Measurement for components as follows:
 Crank web deflections of M/E

 Crank web deflections of A/E (if relevant)

 Axial thrust bearing clearance of shaft syst

 Axial thrust bearing clearance of main and aux


turbine rotors
 Insulation resistance of generators and
essential electrical motors, incl cabling and
swicthgear

1.B. Inter’mdt Surveys (MACHINERY


AND ELECTRICAL INSTALL’TN)
Operation test for components as follows:
 Emg’cy gen-set incl emg’cy switchboard
 Emg’cy bilge valve
 Bilge, ventilation, and monitoring syst for the
carriage of dangerous goods
 Drainage facilities of starting air and control air
receivers
 General operational test of the machinery,
electrical installation, and Automation
equipment

6
1.C. CLASS RENEWAL SURVEY
 To be carried out at the end of class period for
the ship’s items as follows:
– Hull, incl anchoring equipment
– Machinery, incl electrical plant
– Any special equipment classed
 Period: start at 4th annual survey, and must be
completed not exeed in 15 months
 May be carried out in several parts
 Periodical survey and inspections for machinery
and propulsion system is integral part of class
renewal survey
 Class renewals for hull are in sequence (I, II,
III, etc)

1.C. CLASS RENEWAL SURVEY (HULL)


CLASS RENEWAL I (< 5 YRS SHIPS):
 All spaces and hull structural elements,
particularly those areas exposed to fatigue and
corrosion:
– Cargo holds, Tanks, Hatch
– Bow visor, side and stern doors
– Engine foundation, piping systems
 Tanks:
– Seawater ballast tanks (at discretion)
– F.o, l.o, and feedwater need not to be emptied
 Tightness test: subjected to Pressure test
– Each compartment of d/b
– Bulkhead (attached to ship structure)

You might also like