This document describes construction of the USB interface units
STC-H345, STC-H354, STC-H356, STC-H357 and their operation. The devices are necessary
for voice (or other complicated audio signal) logging, monitoring and analysis systems.
In case of any questions, please don’t hesitate to contact us: Our developers are always
ready to assist you.
E-mail: help@speechpro.com
Web-site: http://www.speechpro.com
We hope that you would like our product. Please note that we are always ready to
develop any customized solution for you. Any questions on our products and development
costs should be addressed to our Sales department: sales@speechpro.com).
Copyright
Copyright© 1999-2008 by (STC Ltd.). All rights reserved.
Disclaimer
Speech Technology Center accepts no liability whatsoever for any loss or injury incurred by the
owner or by any third party while using this product and its Technical Description and specifically
disclaims any warranties, merchantability or fitness for any particular purpose.
The contents of the Technical Description are subject to change without notice.
2
Technical Description Interface Units
CONTENTS
1 TECHNICAL DESCRIPTION............................................................4
1.1 Functions.............................................................................................. 4
1.2 Connectors and constructs .................................................................. 4
2 CONNECTIONS TO SIGNAL SOURCES................................................... 5
2.1 Connections of the STC-H345............................................................. 5
2.2 Connections of the STC-H354............................................................. 5
2.3 Connections of the STC-H356............................................................. 6
2.4 Connections of the STC-H357............................................................. 7
3 CONNECTION TO THE TCP/IP NET ......................................................... 7
3.1 Net settings by default ......................................................................... 7
3.2 IP addresses conflict resolution ........................................................... 8
4 WORKING WITH THE DEVICE .................................................................. 8
4.1 Device information getting ................................................................... 8
4.2 Device configuring ............................................................................... 9
4.3 Software renovation ........................................................................... 12
4.4 Technical support............................................................................... 12
5 CONNECTION TO REGISTRATION SYSTEMS...................................... 12
5.1 Driver installing .................................................................................. 12
5.2 Configuration files .............................................................................. 13
5.3 Debugging log.................................................................................... 13
5.4 Control of the record channels .......................................................... 14
Appendix A CONTACTS .............................................................................. 15
Appendix B DEVICE SETTING WITH S1 AND S2 SWITCHES.................. 17
3
Interface Units
4
Technical Description
RJ-45 – connector (8P8C) for connection with TCP\IP nets. Optional power supply
(STC-H345, STC-H356, STC-H357) by PoE (Power over Ethernet) standard (IEEE
Std.802.3af) or from the УАТС 48 В battery with any polarity is possible. Contacts of
the contactor are described in the Table A2.
RS-232 – for connection with devices of controlled terminals (optional).
S1 and S2 – switches S1 and S2 set multiplication factor in the first and second
channels correspondingly for digital subscriber lines. Switch positions for different
types of digital lines are shown in the Table B1. Dependence of the multiplication
factor from switch position is shown in the Table B2.
Status light +5 V is at the DC 5V connector.
«Reset» button for return default net settings is on the case underside.
On the device case, there are keeper strips for bolting to a surface or installing to a
cabinet.
5
Interface Units
6
Technical Description
If distance between the interface unit and digital channels’ draw-off points is more than two
meters, matching unit MC-006 and cables KC-039, KMC-003 are necessary. Before connection
with subscriber lines, S1 and S2 switches must be set in accordance with the Table B1. S1 and
S2 switches of the matching unit MC-018 must be set in accordance with the Table B1 demands
to type of the digital line.
7
Interface Units
Default settings can be tuned. On the case underside, there is a Reset button for return
default settings.
8
Technical Description
The Configuration \ Network settings page (Figure 8) is for adjusting net settings. There are
two variants of adjusting:
1. Obtain an IP address automatically. DHCP server automatically produces an IP
address for the device. It is possible to tune DHCP server so that it produces appointed
IP address for the device with certain MAC address.
2. Use the following IP address. In such case, it is necessary to point out net
parameters of the device:
IP address – IP address of the device;
Subnet mask – mask of the subnet;
Default gateway – IP address of the default gateway;
Preferred DNS server – address of the DNS server;
Link speed Auto/100 Mbit/10 Mbit – speed of data transmitting.
9
Interface Units
10
Technical Description
Mezzanine board type – type of installed additional board (The mezzanine is a subsidiary
board mounted on the main board of the device. It is used for device enhancement – e.g. to
increase number of inputs from 2 to 8):
in the STC-H354, STC-H207 mezzanine is installed;
in the STC-H356, STC-H253 mezzanine is installed;
in the STC-H357, STC-H204 mezzanine is installed.
Phone lines reset – debugging parameter; it is recommended to switch it on in special
cases only.
Long line feature – feature of a long subscriber line. This mode is used if connection point
with a long line subscriber line is near the PBX. In this mode, the PBX signal is detecting at high
threshold value and signal of a telephone set is detecting at low threshold value. It is not
recommended to use the mode needlessly.
Long line invertion feature – feature of a long subscriber line invertion. This mode is used
if connecting point with a long subscriber line is situated in the neighbourhood with the telephone
set, far from the PBX. In this mode, the PBX signal is detecting at low threshold value and signal
of a telephone set is detecting at high threshold value. Before switching to the mode, it is
necessary to switch on the Long line feature mode. It is not recommended to use the mode
needlessly.
The Configuration \ Date and Time page (Figure 10) is for setting astronomical time in the
system. Time counter resets at reload or power down.
11
Interface Units
12
Technical Description
To use the virtual driver, applications get the path to the driver InetDevice.dll from this
parameter.
13
Interface Units
14
Technical Description
Ap p endix A
CONTACTS
Table A1 – Contacts of the Input contactor (DHR-44)
1 Input 1.1 STC-Н345 Input 1.1 STC-Н345 Input 1.1 STC-Н345 Input 1.1 STC-Н345
2 Input A1 STC-Н253
3 Input B1 STC-Н253 Input 3.2 STC-Н204
4 Input C1 STC-Н253 Input 3.1 STC-Н204
5 Input A2 STC-Н253
6 Input B2 STC-Н253 Input 4.2 STC-Н204
7 Input C2 STC-Н253
8 Input A3 STC-Н253
9 Input B3 STC-Н253 Input 4.1 STC-Н204
10 Input C3 STC-Н253
11 Input A4 STC-Н253
12 Input B4 STC-Н253
13 Input C4 STC-Н253
14 Input 3.2 STC-Н207 Input B8 STC-Н253
15 Input 3.1 STC-Н207 Input A8 STC-Н253
16…19 Global Bus Global Bus Global Bus Global Bus
20 Power +5В Power +5В Power +5В Power +5В
21…24 Global Bus Global Bus Global Bus Global Bus
25 Power +5В Power +5В Power +5В Power +5В
26…29 Global Bus Global Bus Global Bus Global Bus
30 Power +5В Power +5В Power +5В Power +5В
31 Input 2.2 STC-Н345 Input 2.2 STC-Н345 Input 2.2 STC-Н345 Input 2.2 STC-Н345
32 Input 2.1 STC-Н345 Input 2.1 STC-Н345 Input 2.1 STC-Н345 Input 2.1 STC-Н345
33 Input 1.2 STC-Н345 Input 1.2 STC-Н345 Input 1.2 STC-Н345 Input 1.2 STC-Н345
34 Global Bus Global Bus Global Bus Global Bus
35 Input 7.1 STC-Н207 Input B5 STC-Н253
36 Input 8.1 STC-Н207 Input A5 STC-Н253
37 Input 8.2 STC-Н207 Input A6 STC-Н253
38 Input 7.2 STC-Н207 Input C5 STC-Н253
39 Input 5.1 STC-Н207 Input C6 STC-Н253
40 Input 6.1 STC-Н207 Input B6 STC-Н253
41 Input 5.2 STC-Н207 Input A7 STC-Н253
42 Input 4.1 STC-Н207 Input C7 STC-Н253
43 Input 4.2 STC-Н207 Input C8 STC-Н253
44 Input 6.2 STC-Н207 Input B7 STC-Н253
15
Interface Units
16
Technical Description
Ap p endix B
DEVICE SETTING W ITH S1 AND S2 SWITCHES
Table B1 – Positions of the S1 и S2 switches for different PBX
Type of PBX or subscriber Type of settings Switch position of S1 and S2
line
1 2 3 4
E1 ISDN PRI 00 on - - -
ISDN BRI 01 - - on -
Alkatel - Lucent 03 - on - -
Avaya - Lucent 00 on - - -
Bosch 00 on - - -
Ericsson 02 - - - on
Ericsson ELU5 02 - - - on
Harris 03 - on - -
LG 01 - - on -
NEC 01 - - on -
Nortel, Mercator 05 - - - -
Nortel, Meridian 03 - on - -
Nortel, Norstar 03 - on - -
Panasonic 04 on - on on
Samsung 01 - - on -
Siemens 00 on - - -
Siemens U200 00 on - - -
Tadiran Telecom, Coral 00 on - - -
Информтехника, МиниКом 00 on - - -
Table B2 – Dependence of the multiplication factor from switch positions
Switch position of S1 or S2
Multiplication factor
1 2 3 4
- - - - 4,70
- - - on 3,10
- - on - 2,04
- - on on 1,66
- on - - 1,3
- on - on 1,14
on - - - 1,02
- on on - 0,96
on - - on 0,92
- on on on 0,86
on - on - 0,79
on - on on 0,73
on on - - 0,65
on on - on 0,61
on on on - 0,55
on on on on 0,52