Of Flow
Measuring
Devices .
Dr. S & S.S
Ghandhy
Collage
Subject :- M & I
Branch :- MECH (D-3)
Topic:- Flow Measuring
Devices.
Prepared by :- Rampariya Milan
E .N nO :- 096120319052
Introduction
In metering liquids,gases,or
stem and in process control in
various industries ,the quantity of
fluid passing through the cross-
section of a pipeline per unit time
or over a certain time interval is
often the requirement.
Classification of flow
mesuring devices
Pressure differential created
by placing restriction in flow line
i.e. differential head meters.
Local or point velocity and
pressure mesurement method-
i.e.Pitot-tube velocity & flow
meters.
Constsnt differential head flow
meters or variable area fiow meters.
Volume flow meters,magnetic
flow meters.
We will therefore,classify
them as::-
V.V=2gH….(a)
Q=A*V….(b)
Where,A=cross-section area of the
pipelines
Venturi meter
A U-tube manometer is used
to measure pressure head
difference ,’h’ between inlet and
throat as shown.
oOrifice Meter
An orifice plate has a sharped edged concentric
circular hole.Normally it is made from stainless steel
from 3mm to 12.5mm thick. Orifice plate has many
varieties.
Advantages:
(1) Chear in cost.
(2) Occupies less space.
Disadvantages:
(1) High pressure drop.
(2) Slurry or solid particles damage the hole.
Advantages:
Disadvantages:
(1) Occupies more space
(2) Not suitable for pipe
diameter less then 76.2mm.
(3) Costly.
Flow Nozzle
The fiow nozzle is fabricated from stainless
steel,gun metal etc.It is fitted either in pipe or
in tank.
Advantages:
(1) Suffer less pressure drop compared to
orifice meter
(2) Occupies less space.
Disadvantages:
(1) Costly compared to orifice
(2) Suiteble upon medium sized pipes.
Rota meter
It is a device used to measure fiow rate
of a fluid.It consists of a vertical tapered
tube with a flote which is free to move within
the tube.The fluid enters the devie from
bottom and flows upward.When there is no
flow the float rest at the bottom.
Advantages:
(1)Float position
can be seen.
(2)Good accuracy
for low flow rate.
(3)Remote
indication possible.
Disadvantag-
es:
(1)Glass tube is
fragile.
(2)Float cannot be
seen if the fluid is
dense.
Electromagnetic
Meter
It works an
Faraday’s
electromagnetic
induction principal. A
magnetic field is
produced within the
pipe,in which fluid flow
is to be mesured,by the
magnets place outside
the pipe..
Advantages:
1)No obstruction,no
(
pressure drop.
(2)No moving parts,no maintenance.
(3)Can function even if the flow is reversed.
Disadvantages:
(1)Fluid must be electrical conductor.
(2)Air trap must be avoided.
(3)Costly.
Ultrasonic Meter
Here altrasonic
transdusars are used
either parallel to pipe
wall or placed at
some angle.When
ultrasonic waves are
passed through the
fluid,the velocity of
waves increases
or decreases depending upon the
direction of fluid flow.Piezo-electric
transducers A and B generate
ultrasonic waves and transmits them
through the fluid.The fluid velocity is say
V.