Professional Documents
Culture Documents
¾ Process Industry
• Product – PRISM – P (Process Integration Software for Management)
¾ Water Resource
• Product – PRISM – W (Powered Irrigation Software for Management)
These solutions typically include SCADA control centers HW & SW, telecommunication
systems, RTUs, field instrumentation and interfaces, advanced software applications,
comprehensive engineering, Project management, maintenance and training.
SCADA solutions are designed to satisfy all the actual Industry requirements, ranging from
complex, feature-rich and distributed remote control capability, to cost-effective, easy-to-use
for smaller applications.
Genus Power Infrastructure Limited... Your IT Partner
Genus Power Infrastructure Limited
(Kailash Group Company)
ISO-9001:2000 Certified
Objectives of SCADA System
• Absolute Monitoring
SCADA Client SCADA Client
• Accurate Measurement Report
• Automated Data Logging Printer
• Precise Accounting
• Perfect Auditing of Energy
Effective Controlling
Efficient Management of: Other systems:
Schedule Load shedding SCADA
GIS / BILLING / IVRS
Emergency Load Shedding Server Gateway
Fault localization Master Control Unit
Supply restoration
Preventive Maintenance
Improve Quality of the Supply • LAN / OFC
Reduce the Distribution Losses • LL / ISDN/ PLCC
• UHF / ISM
Primary Functions: • GSM/GPRS/CDMA
• VSAT Web Client
Measurement
• Periodical Measurement
• Selected Time Measurement
• On-Demand Measurement
• Pulse Accumulation
• Threshold Detection
Status
• Status Change Detection
• Event with Time Stamping RTU Protection & Control Panel
• Sequence of Event Distribution / Transmission / Generation Substation
Control
• Select Check and Execute
• Set Point Control Major Components of the System:
• Open / Close • Master Control Unit (MCU)
• Rise / Lower • Communication System
System Logs & Reports • Remote Terminal Unit
•Alarm & Event Status
Benefits of PRISM-SCADA
• Data Logs & reports
Operational Investment Savings by:
Operational parameters acquired in real time:
• Optimization of MVAR Flow
• Voltage (3 phase) • Improved Voltage Regulation
• Current (3-Phase) • Enhanced Equipment Life
• Power factor • Reduction of Losses
• Frequency • Optimum Utilization of Resources & Manpower
• Active Power • Instant Fault Identification
• Reactive Power • Data for Analysis & Planning Studies
• RTU Status Increasing System Availability by:
• Energy in KWH (accuracy Class 1 / 0.5) • Faster Detection of Abnormality
• Circuit Breaker status - open or close
• Real Time Data Availability for Decision Support
• Protection Relay Status
• Isolator Status • Efficient Restoration
• Crew Management
Supervisory Control Increasing Revenue by:
Circuit Breaker (open / Close) • Improved Quality of Supply
Tap Position ( Rise/ Lower) • Better Quality of Service
Alarm Acknowledge • Improve Overall System Performance.
Alarm Reset • Improved Utility Image
Genus Power Infrastructures Limited, SPL-3, RIICO Industrial Area, Sitapura Tonk Road, Jaipur -302002 (INDIA)
Phone : +91 141 2770003/4/9, 2770401/02, Fax: +91 141 2770319, 2220455 E-mail: scada@genus.in
Genus Power Infrastructure Limited
(Kailash Group Company)
ISO-9001:2000 Certified
A. ELECTRIC INDUSTRY
A1. Substation Automation (MCC) :
Cluster Applicati
on
Roster
Management &
Web
Portal
Anti-
Virus
Engineering & Roster Management,
Server Server Load Forecasting Server Server Development Operation & MIS
Server
Workstation Reporting
Workstation Report
Printer
.
.
P
S
• .
GPRS/CD
MA/VSAT
/Leased Router
Line
MFT MFT
3 Ph 4W 3 Ph 4W 3 Ph 4W
CT-PT Box
Genus Power Infrastructure Limited... Your IT Partner
Genus Power Infrastructure Limited
(Kailash Group Company)
ISO-9001:2000 Certified
• .
Model AT91RM9200,
32Bit Embedded
Processor)
RAM 64 MB SDRAM
Port 1 port
USB
Load Forecasting
Software Tools : -
.
• .
Load Forecasting method includes several varieties of Regression , Time Series , Similar
Day Look up. and Artificial Neural Network techniques .
Regression Based Approaches .:
(i ) Linear Regression (ii) Piecewise Regression
Time Series Analysis :
Modeling pattern is a time series plot.
Extrapolating those patterns to the future
Using historical data as input
Ffitting a model according to trend
Total
TotalOptimization
Optimization
Management
EnvironmentalManagement
Sub-Station
Sub-StationControl
Unit Optimizations
Minimize Right
Minimize Maximize
Maximize Optimal
Optimal Right
Set-
Change
ControlSystem
Efficiency Monitoring
Central
CentralMonitoring
MonitoringSystem
System
System
Reliable Process Data
Gross
GrossError
ErrorDetection
Detection&&Data
DataReconciliation
Reconciliation
Raw Data
Work - Flow
GEM.EXE
• . • .
Automatic DB
Generation
GUI DB Check
GUI Editor
Main GUI
A2. DT Automation
System Architecture
132 KV
• .
33 KV
11 KV
Primary Functions : BCS software is prepared on C++ and Visual C platforms in user friendly
enviourment with attractive GUIs to cater various needs of power utilities for Increased efficiency-
reduced human error , Increased data reliability and consistency, Timeliness of information-obtain
data whenever needed , Alarms for exceeding data thresholds and system health and Data and system
validity checks enhance data quality.
User Management
(i) User-Code
(ii) User Name
(iii) Password
(iv) Level of User
Communication
(i) SMS : This menu has Configuration option giving base
station details, Energy Time slot ,data mode user
addition/ deletion ,MD Reset date & Time, V-I
imbalance and process time.
(ii) System Parameters : Instantaneous values, MD value,
consumer & meter detail , signal strength etc.
(iii) Selective Dialing :Load survey/Events/Billing data for a
specific meter.
(iv) Selective Dialing :Data retrieval Daily/Weekly/ or
Monthly at desired time for a group of meter.
(iii) Reports:In the report section the analysis & graph of
every meter can be seen and events like Phasor, load-
survey, voltages, currents, power billing parameters,
summary of different meter.
(iv) In reports section there is SMS log menu in which the
SMS received from the assigned meters can be viewed
different SMS values like instant, energies, MD values,
tampers ,signal strength can be seen for every particular
day.
Genus Power Infrastructure Limited
(Kailash Group Company)
ISO-9001:2000 Certified
B. PROCESS INDUSTRY
B1. Industrial Automation
Objectives :
• Functional Specifications
• Technical Specifications
• Implementation Standards
• Product Application Engineering
• Software Engineering & Testing
• System Engineering & Testing
Technology Partners
¾ M/s. Vitzrosys, South Korea
¾ M/s. Analogic, Hyderabad
C. WATER RESOURCES
C1. Water Resource Plant