Professional Documents
Culture Documents
3 Chemical Storage Internal Waste Disposal (chemical Mixing of chemicals within 4 3 Chemical room access limited to 3 36 Yes, no mixing N Add labels to chemical D. Ross by 1/31/03
and Transport room, VFS final test, hydraulics storage barrels, causing Plant Engineer and 2nd shift permitted by room walls specifying
testing, Visteon audit) possible hazardous maintenance, who ensure correct disposal location of each barrel
combinations barrels are used company type
Review Site BLDI by 1/31/03
Identification form to
see if we need to
resubmit
Storage of waste while waiting for Surface water pollution 5 4 Waste hauler takes container 2 40 No N Review waste pickup Running inventory. D. Ross by 12/31/02
disposal company to pick up. (Spillage from container from chemical room (no storage schedule to ensure we
onto loading dock or into period on loading dock) don't exceed 100 kg
truck well) per month.
Storage of waste and "fresh" Leaks and spills into ground 4 3 All chemicals stored over steel 1 12 No N Characterize all wastes BLDI by 1/31/03
chemicals water lined cement spill containment
area in chemical room
Transporting waste from point of Spillage within building 2 2 Due Care used by personnel 3 12 No N
use to chemical room beyond chemical room
containment
Transporting "fresh" chemicals Spillage within building 2 2 Due Care used by personnel 3 12 No N
from loading dock to chemical beyond chemical room
room or from chemical room to containment
point of use within building (VFS
final test, hydraulics testing, wave
solder, Visteon audit)
Waste transport by sub-contracted Improper disposal 5 5 Licensed disposal company used 1 25 Yes, for disposal N
disposal company
Spillage along roads 5 5 Licensed disposal company used 1 25 Yes, for disposal N
In-house storage capacity for Possible surface and 4 4 Running inventory of capacity 1 16 Yes. 1320 N Stay below 1320 Running inventory. D. Ross Begin Jan
transmission and motor oil ground water contamination gallons gallons capacity at all 2003
if capacity is exceeded maximum times
allowed without
reporting
Write SPCC plan if we BLDI by 5/31/03
are over 1320 gallons
capacity
Handling and storage of universal Ground water contamination 2 4 Universal wastes seperated and 3 24 Yes N Implement standard D. Johnson by 12/31/02
wastes (landfill leachate) disposed of by licensed handler, operating procedure D. Ross
as per SOP 5151. (5151) for handling
universal and
hazardous wastes
4 Solder Emissions Wave solder, VFS/RFE solder pot, Air pollution 2 2 Periodic air quality testing 5 20 Yes, air permit N Determine if laws / BLDI to test emissions (ppm). BLDI by 2/28/03
(Tin, Lead, Flux) into wave solder washer, operations may be required regulations require us Outside consultant review of
atmosphere using solder irons to have permits under regulations.
MAERS.
59781131.xls 06/02/2011
Aspect - Impact Environmental Assessment Form
Saturn Electronics & Engineering, Inc.
Coopersville Plant
6 Transmission Fluid VFS final test, hydraulics testing Air pollution 2 2 none 5 20 Yes, air permit N Issue quote request for Unit installed Nov. 2002 D. Ross by 12/31/02
Vapor Emissions may be required vapor recovery system.
Install system if
feasable.
Ground water contamination 2 3 none 5 30 Yes, air permit N Issue quote request for Unit installed Nov. 2002 D. Ross by 12/31/02
(emissions condense on may be required vapor recovery system.
roof, then washed into Install system if
ground) feasable.
7 Transmission Fluid VFS final test, hydraulics testing Spillage within building 2 2 Trap pans under testers, 4 16 No N Write procedure to D. Johnson by 11/21/02
collects under beyond chemical room vacuumed up as necessary. specify containment D. Ross
testers containment Vacuum then emptied into and clean-up of spills
storage barrel in chemical room.
8 Wastewater Better Engineering parts washer, Surface water 3 3 Due Care used by personnel to 3 27 Yes, stormwater N Investigate using an oil D. Ross by 12/10/02
Disposal mop buckets, floor scrubber contamination. dispose wastewater only into runoff seperator to clean
sanitary sewer system wastewater before
disposal.
9 Disposal of oily rags Maintenance, VFS final test, Ground water contamination 2 3 None for gloves. Subcontracted 4 24 No N
and gloves hydraulics testing (landfill leachate) service for rags
10 Storm water runoff Truck well, parking lot Surface water 2 2 none 5 20 Yes, stormwater N Write Emergency Plan D. Ross by 12/31/02
contamination (from oil) runoff K. Stebbins
Outside storage of pallets and Surface water 2 2 none 5 20 Yes, stormwater N Require protected No metals stored revise EMS monthly checklist J. Zerfas
metal contamination. runoff storage of metals. outside to include this requirement D. Johnson
(pallets will remain (11/22/02). BLDI to review BLDI
outside). Put Coopersville stormwater
Stormwater Pollution ordinance (by 12/31/02).
Prevention Plan in BLDI to determine if SWPPP
place is needed (by 1/31/03). If
needed, SWPPP to be
complete by 7/1/03
Outside storage of empty alcohol Surface water 2 2 none 5 20 Yes, stormwater N Write procedure to revise EMS monthly checklist J. Zerfas by 11/15/02
& flux containers and empty spools contamination. runoff specify that pallets of to include this requirement D. Johnson
for recycle pickup these containers must
be shrink wrapped,
including exposed tops
Contractors dispose of their scrap Surface water contamination 2 2 none 3 12 Yes, stormwater N Explain our D. Ross when work is
when performing work for Saturn runoff requirements to performed
contractors.
11 Transformers All Ground water contamination 4 4 Transformers will be tested for 1 16 Yes, for disposal N Consumer's Power to 2/25/03: Consumers tested Consumer's by 7/31/03
containing PCBs at disposal PCB content before disposal per test all unlabeled transformers. We are below Power
Michigan Administrative Code # R transformers pcb threshold. Certification
299.3313 -3317 sticker to be applied to pig
Spring 2003.
59781131.xls 06/02/2011
Aspect - Impact Environmental Assessment Form
Saturn Electronics & Engineering, Inc.
Coopersville Plant
12 Solder Dross Wave solder, Solder pots Ground water contamination 4 4 Only licensed disposal company 2 32 Yes, for disposal N
disposal used (for recycling)
13 Lawn Chemical Upkeep of building grounds Ground water contamination 2 2 No DEQ forbidden componds 1 4 No N Obtain certification K. Stebbins by 10/31/02
usage (sub-contracted) used by lawn service from lawn service J. Zerfas
Surface water 2 2 No DEQ forbidden componds 1 4 No N stating no forbidden
contamination. used by lawn service chemicals used
14 Paper and All Landfill usage 2 3 none 5 30 No Y Implement cardboard Reduce trash Monitor and graph how often K. Mercer Recycling
cardboard usage recycling. compactor volume by the trash container is D. Ross company to be
20% by Jan, 2004 changed (by month) starting S. Carlson chosen by
in Jan 2003 1/31/03
15 Conformal coating of Electronics (John Deere module Air pollution 3 3 Performed outside, no point 5 45 Yes, SARA title N Get customer approval Check customer K. Baker by 2/14/03
circuit boards only) discharges III, for current to use a coating that is requirements. If customer A. Hamelink
compound used more environmentally does not specify Humiseal,
(Humiseal) friendly use a different compound.
Review of new compounds is
in progress
16 Trash compactor All Surface water 2 2 none 5 20 No N Write instruction stating S. Carlson by 11/15/02
(excessive litter contamination. that area must be D. Johnson
when changing cleaned before new
container) container is placed.
17 Painting done Model Shop, Maintenance Air pollution 2 2 Performed outside, no point 3 12 No N
outside, no spray discharges
booth
Surface water 2 2 Performed outside, no point 3 12 No N
contamination. discharges
Ground water contamination 2 2 Performed outside, no point 3 12 No N
discharges
18 Miscellaneous use Research & Development Air pollution 2 2 Due care used by personnel 3 12 Yes, air permit Y Put policy in place that Reduce the number of Written policy and employee K. Stebbins Policy to be in
of hazardous Model Shop may be required no sales samples or hazardous chemicals training place by
chemicals other chemicals are to used by 10% by Jan, 10/31/02
Surface water 2 2 Due care used by personnel 3 12 Y be used until an 2004 Keep running inventory of D. Ross Inventory to be
contamination. environmental review is different chemicals used complete by
done. Also reduce the 12/31/02.
Ground water contamination 2 2 Due care used by personnel 3 12 Y number of hazardous Begin running
chemicals used inventory in
Jan 2003
19 Pesticide use Kill mice Surface water contamination 3 3 Trap opening protected by 2 18 No N Current traps to be Traps to be removed by D. Ross by 11/5/02
building overhang removed. All future 11/5/02
traps used to be
evaluated for
environmental impacts
before use (type of
poison and placement)
20 Lead (Pb) useage Soldering operations. Electric hi- Inventory (including 2 2 Environmental consultant (BLDI) 3 12 Yes, reportable if N Improve inventory Tighten the window for solder J. Zerfas by 12/31/02
lo. Electric transport cart. batteries) exceeds permitted to perform initial assessment and 100 lbs. on site is control of on-hand deliveries, through JBA and C. Sweers
amount. Amount above training of Saturn personnel in exceeded quantity of solder working with supplier.
permitted level triggers TRI TRI form R requirements (SARA
form R reporting Title III)
requirements
21 Use of chemicals Circuit board conformal coating. Air pollution 2 2 Due care used by personnel 3 12 Yes N see # 18 see # 18 Perform review of all MSDS BLDI by 7/31/03
that are reportable R&D activities. Maintenance sheets to determine which
under SARA Title III activities chemicals are above the
reporting threshold. Report
these chemicals as needed.
Surface and ground water 2 2 Due care used by personnel 3 12 Yes N
Prepare contingency plans.
contamination
59781131.xls 06/02/2011
Aspect - Impact Environmental Assessment Form
Saturn Electronics & Engineering, Inc.
Coopersville Plant
59781131.xls 06/02/2011
Objectives
completed
on (date)
59781131.xls 06/02/2011
Objectives
completed
on (date)
59781131.xls 06/02/2011
Objectives
completed
on (date)
59781131.xls 06/02/2011
Objectives
completed
on (date)
59781131.xls 06/02/2011
Scale of Impact
How much of an impact will the aspect make on the environment?
How heavily will the impact (based on the given aspect) affect the environment?
Severity of Impact
Based on the Scale of impact, how severe is the impact?
Take into account how long the impact will have a negative effect.
Prob/Freq of Occurrence
How frequently will the specified impact occur?
Take into account:
a. Any control method(s) placed on the aspect and/or impact
b. The activities associated with the aspect and/or impact
c. How the activities are performed
d. Our history performing the activities.