You are on page 1of 2

PLC

(Programmable Logic Controller)


Characteristics: have individual control while allowing the sub-systems to co-ordi-
nate over the communication link.
• Modular design
• HSE controller These communication links are also often used for HMI devices
• All-in-one CPU such as PC workstations.
• Universal temperature input module (RTD and thermocou-
ple) Some of today’s PLCs can communicate over a wide range of me-
• Online maintenance dia including RS-485, Coaxial, and even Ethernet.
• Ethernet communication (FOUNDATION™ HSE and/or
Modbus TCP Under the IEC 61131-3 standard, PLCs can be programmed using
• Access via internal bus for up to 64 conventional I/O modules standards-based programming languages. Most PLCs utilize Lad-
• Discrete control through ladder language in compliance with der Logic Diagram Programming, a model which emulates electro-
IEC 61131 mechanical control panel devices (such as the contact and coils of
relays). This model remains common today.
As a process control system, SMAR System302 also complies with
standard PLC requirements and based on a modular design, there SMAR has been supplying solutions for PLC market in several seg-
is a specific processor module (DF75) designed for PLC which ments as below:
performs all functions exposed along this document.
1. Boiler Automation
It is well-adapted to a range of automation tasks. These are typi- 2. Sugar Mill Automation
cally industrial processes in manufacturing where the cost of de- 3. Steam Generation
veloping and maintaining a customized automation system is high 4. Burner Automation
relative to the total cost of a PLC automation, so the cost is low 5. Mining Refining
compared to the cost of a specific custom-built controller design 6. Ethanol Production
and where changes to the system would be expected during its 7. Sugar Production
operational life. 8. Leak Detection

Modular PLCs as SMAR System302 have a chassis (also called a Characteristic SYSTEM302 Availability
rack) into which are placed modules with different functions. The
Physical Points (I/O) 1024
processor and selection of I/O modules is customized for the
particular applications. Virtual Points 4096
Modbus-RTU 1 x EIA-232 gate
Several racks can be administered by a single processor, and may Function Blocks up to 1200
have thousands of inputs and outputs. Modbus Slave Yes
Function Blocks 100
A Human-Machine Interface (HMI) is employed for interacting
with operation personnel for the purpose of configuration, alarm OPC support Yes
reporting and everyday control. Foundation Fieldbus HSE/Modbus 2 x 10/100Mbps ports
TCP
Modern PLCs can communicate over a network to some other VAC Power Supply 90 to 264VAC
system, such as a computer running a Supervisory Control and VDC Power Supply 20 to 30VDC
Data Acquisition system or web browser. Redundancy support Yes (CPU only)

PLCs used in larger I/O systems have communication between For additional information please contact us.
processors. This allows separate parts of a complex process to
SYSTEM302 Improves Asset Management Interface
www.smar.com
Specifications and information are subject to change without notice.