Vertical Upflow

Air Handlers
With Electric Heat
2TFB4018, 24, 30, 36A1D05, 08, 10A
2TFE4025A1D05, 08, 10A

PUB. NO. 22-1753-01-0404 (EN)


Features and
Benefits

2TFB4 Standard Equipment


• Shipped in vertical upflow, bottom • Easy access electrical controls and • Internal mounted expansion valve kits
return with front access & convertible to hook-up available
vertical upflow front return • 200/230 volt primary and 24 volt • Approved for modular or manufactured
• Tight cabinet - low leakage by design secondary transformer homes
• Attractive enamel finish • Built-in indoor fan delay function for • Factory installed service disconnect
• R 4.2 – 1" insulation increased efficiency. No kit required. • Internally enhanced finned coil tubing
• Exclusive easy clean coil and drain pan • Multi-speed blower • Primary and secondary drain
• Easy to remove filters and blowers for • Direct drive motor connections
easy cleaning and replacement • Factory installed electric heaters • Optional extended warranties
• Filter rack with throwaway filter • AccuTron™ refrigerant control • Five year limited parts warranty

2TFE3 Standard Equipment


• Shipped in vertical upflow, bottom • R 4.2 – 1" insulation • Factory installed electric heaters
return with front access & convertible to • Exclusive easy clean coil and drain pan • Expansion valve refrigerant control
vertical upflow front return
• Easy to remove filters and blowers for • Factory installed service disconnect
• Variable speed ECM motor easy cleaning and replacement • Internally enhanced finned coil tubing
• Enhanced Comfort-R™ • Filter rack with throw away filter • Primary and secondary drain
• Soft start – cycle-on speed is ramped • Easy access electrical controls and connections
up gradually to reduce sound and draft hook-up • Approved for modular or manufactured
• Low voltage terminal board • 200/230 volt primary and 24 volt homes
• Tight cabinet – low leakage by design secondary transformer • Optional extended warranties
• Attractive enamel finish • Built-in indoor fan delay function for • Five year limited parts warranty
increased efficiency. No kit required.

OPTIONAL EQUIPMENT FOR HEATING UNITS


Evaporator Defrost Control Kit All Cooling Models .................................................................................................... AY28X079 [ ]
Evaporator Defrost Control Kit All Heat Pump Models ............................................................................................... AY28X084 [ ]

© 2004 American Standard Inc. All Rights Reserved 2 22-1753-01-0404 (EN)


Contents

Features and Benefits 2


2TFB4 Standard Equipment 2
2TFE3 Standard Equipment 2
Optional Equipment For Heating Units 2

General Data 4
2TFB4018A1D05A 4
2TFB4018A1D08A 4
2TFB4018A1D10A 4
2TFB4024A1D05A 5
2TFB4024A1D08A 5
2TFB4024A1D10A 5
2TFB4030A1D05A 6
2TFB4030A1D08A 6
2TFB4030A1D10A 6
2TFB4036A1D05A 7
2TFB4036A1D08A 7
2TFB4036A1D10A 7
2TFE3025A1D05A 8
2TFE3025A1D08A 8
2TFE3025A1D10A 8

Performance Data 9
Electrical Data 11
Refrigerant Circuit 13
Dimensions 15

22-1753-01-0404 (EN) 3
General
Data

Product Specifications
MODEL 2TFB4018A1D05A 2TFB4018A1D08A 2TFB4018A1D10A
RATED VOLTS/PH/HZ. 208/230/1/60 208/230/1/60 208/230/1/60
RATINGS 1 See O.D. Specifications See O.D. Specifications See O.D. Specifications
HEATER CAPACITY (Volts) 240v 208v 240v 208v 240v 208v
HEATER CAPACITY (BTUH) 16400 12300 26200 19700 32800 24600
POWER CONNECTION 230v 208v 230v 208v 230v 208v
Min. Brch. Cir. Ampacity 2 27 23 42 36 52 45
Recmd-Max. Overload Protection (amps) 30 25 45 40 60 45
INDOOR COIL - Type PLATE FIN PLATE FIN PLATE FIN
Rows - F.P.I. 3 - 14 3 - 14 3 - 14
Face Area (sq. ft.) 2.43 2.43 2.43
Tube Size (in.) 3/8 3/8 3/8
Refrigerant Control FCCV FCCV FCCV
Drain Connection Size (In.) 3 3/4 PVC SLIP 3/4 PVC SLIP 3/4 PVC SLIP
DUCT CONNECTIONS See Outline Drawing See Outline Drawing See Outline Drawing
INDOOR FAN - Type Centrifugal Centrifugal Centrifugal
Diameter - Width (In.) 10 x 8 10 x 8 10 x 8
No. Used 1 1 1
Speeds (No.) 2 2 2
CFM vs. in. w.g. See Fan Performance Table See Fan Performance Table See Fan Performance Table
Motor HP - RPM 1/5 - 930 1/5 - 930 1/5 - 930
F.L. Amps - L.R. Amps 1.0 / 1.4 1.0 / 1.4 1.0 / 1.4
FILTER — Furnished? Yes Yes Yes
Type Recommended Throwaway Throwaway Throwaway
Hi Vel. (No.-Size-Thk.) 1 - 18 x 20 - 1 In. 1 - 18 x 20 - 1 In. 1 - 18 x 20 - 1 In.
REFRIGERANT CONNECTIONS Brazed Brazed Brazed
Line Size - Gas (in.) 5/8 5/8 5/8
Line Size - Liquid (in.) 1/4 1/4 1/4
DIMENSIONS (in.) HXWXD HXWXD HXWXD
Crated (H X W X D) 40-1/2 x 23 x 20-3/8 40-1/2 x 23 x 20-3/8 40-1/2 x 23 x 20-3/8
Uncrated See Outline Drawing See Outline Drawing See Outline Drawing
WEIGHT (lbs.)
Shipping - Net 115 / 93 115 / 93 115 / 93
1 These Air Handlers are A.R.I certified with various Split System Air Conditioners and Heat Pumps (ARI STANDARD 210/240). Refer to the Split System Outdoor Unit Product Data Guides for performance data.
2 Minimum Circuit Ampacity includes Blower Motor Amps
3 3/4" Plastic Pipe (Ref.: ASTM 1785-76)

4 22-1753-01-0404 (EN)
General
Data

Product Specifications
MODEL 2TFB4024A1D05A 2TFB4024A1D08A 2TFB4024A1D10A
RATED VOLTS/PH/HZ. 208/230/1/60 208/230/1/60 208/230/1/60
RATINGS 1 See O.D. Specifications See O.D. Specifications See O.D. Specifications
HEATER CAPACITY (Volts) 240v 208v 240v 208v 240v 208v
HEATER CAPACITY (BTUH) 16400 12300 26200 19700 32800 24600
POWER CONNECTION 230v 208v 230v 208v 230v 208v
Min. Brch. Cir. Ampacity 2 27 24 42 37 52 45
Recmd-Max. Overload Protection (amps) 30 25 45 40 60 45
INDOOR COIL - Type PLATE FIN PLATE FIN PLATE FIN
Rows - F.P.I. 3 - 14 3 - 14 3 - 14
Face Area (sq. ft.) 2.43 2.43 2.43
Tube Size (in.) 3/8 3/8 3/8
Refrigerant Control FCCV FCCV FCCV
Drain Connection Size (In.) 3 3/4 PVC SLIP 3/4 PVC SLIP 3/4 PVC SLIP
DUCT CONNECTIONS See Outline Drawing See Outline Drawing See Outline Drawing
INDOOR FAN - Type Centrifugal Centrifugal Centrifugal
Diameter - Width (In.) 10 x 8 10 x 8 10 x 8
No. Used 1 1 1
Speeds (No.) 2 2 2
CFM vs. in. w.g. See Fan Performance Table See Fan Performance Table See Fan Performance Table
Motor HP - RPM 1/3 - 1103 1/3 - 1103 1/3 - 1103
F.L. Amps - L.R. Amps 1.4 / 3.3 1.4 / 3.3 1.4 / 3.3
FILTER — Furnished? Yes Yes Yes
Type Recommended Throwaway Throwaway Throwaway
Hi Vel. (No.-Size-Thk.) 1 - 18 x 20 - 1 In. 1 - 18 x 20 - 1 In. 1 - 18 x 20 - 1 In.
REFRIGERANT CONNECTIONS Brazed Brazed Brazed
Line Size - Gas (in.) 3/4 3/4 3/4
Line Size - Liquid (in.) 5/16 5/16 5/16
DIMENSIONS (in.) HXWXD HXWXD HXWXD
Crated (H X W X D) 40-1/2 x 23 x 20-3/8 40-1/2 x 23 x 20-3/8 40-1/2 x 23 x 20-3/8
Uncrated See Outline Drawing See Outline Drawing See Outline Drawing
WEIGHT (lbs.)
Shipping - Net 115 / 93 115 / 93 115 / 93
1 These Air Handlers are A.R.I certified with various Split System Air Conditioners and Heat Pumps (ARI STANDARD 210/240). Refer to the Split System Outdoor Unit Product Data Guides for performance data.
2 Minimum Circuit Ampacity includes Blower Motor Amps
3 3/4" Plastic Pipe (Ref.: ASTM 1785-76)

22-1753-01-0404 (EN) 5
General
Data

Product Specifications
MODEL 2TFB4030A1D05A 2TFB4030A1D08A 2TFB4030A1D10A
RATED VOLTS/PH/HZ. 208/230/1/60 208/230/1/60 208/230/1/60
RATINGS 1 See O.D. Specifications See O.D. Specifications See O.D. Specifications
HEATER CAPACITY (Volts) 240v 208v 240v 208v 240v 208v
HEATER CAPACITY (BTUH) 16400 12300 26200 19700 32800 24600
POWER CONNECTION 230v 208v 230v 208v 230v 208v
Min. Brch. Cir. Ampacity 2 27 24 42 37 52 46
Recmd-Max. Overload Protection (amps) 30 25 45 40 60 50
INDOOR COIL - Type PLATE FIN PLATE FIN PLATE FIN
Rows - F.P.I. 3 - 14 3 - 14 3 - 14
Face Area (sq. ft.) 2.43 2.43 2.43
Tube Size (in.) 3/8 3/8 3/8
Refrigerant Control FCCV FCCV FCCV
Drain Connection Size (In.) 3 3/4 PVC SLIP 3/4 PVC SLIP 3/4 PVC SLIP
DUCT CONNECTIONS See Outline Drawing See Outline Drawing See Outline Drawing
INDOOR FAN - Type Centrifugal Centrifugal Centrifugal
Diameter - Width (In.) 10 x 8 10 x 8 10 x 8
No. Used 1 1 1
Speeds (No.) 2 2 2
CFM vs. in. w.g. See Fan Performance Table See Fan Performance Table See Fan Performance Table
Motor HP - RPM 1/3 - 1125 1/3 - 1125 1/3 - 1125
F.L. Amps - L.R. Amps 1.5 / 4.1 1.5 / 4.1 1.5 / 4.1
FILTER — Furnished? Yes Yes Yes
Type Recommended Throwaway Throwaway Throwaway
Hi Vel. (No.-Size-Thk.) 1 - 18 x 20 - 1 In. 1 - 18 x 20 - 1 In. 1 - 18 x 20 - 1 In.
REFRIGERANT CONNECTIONS Brazed Brazed Brazed
Line Size - Gas (in.) 3/4 3/4 3/4
Line Size - Liquid (in.) 5/16 5/16 5/16
DIMENSIONS (in.) HXWXD HXWXD HXWXD
Crated (H X W X D) 40-1/2 x 23 x 20-3/8 40-1/2 x 23 x 20-3/8 40-1/2 x 23 x 20-3/8
Uncrated See Outline Drawing See Outline Drawing See Outline Drawing
WEIGHT (lbs.)
Shipping - Net 115 / 93 115 / 93 115 / 93
1 These Air Handlers are A.R.I certified with various Split System Air Conditioners and Heat Pumps (ARI STANDARD 210/240). Refer to the Split System Outdoor Unit Product Data Guides for performance data.
2 Minimum Circuit Ampacity includes Blower Motor Amps
3 3/4" Plastic Pipe (Ref.: ASTM 1785-76)

6 22-1753-01-0404 (EN)
General
Data

Product Specifications
MODEL 2TFB4036A1D05A 2TFB4036A1D08A 2TFB4036A1D10A
RATED VOLTS/PH/HZ. 208/230/1/60 208/230/1/60 208/230/1/60
RATINGS 1 See O.D. Specifications See O.D. Specifications See O.D. Specifications
HEATER CAPACITY (Volts) 240v 208v 240v 208v 240v 208v
HEATER CAPACITY (BTUH) 16400 12300 26200 19700 32800 24600
POWER CONNECTION 230v 208v 230v 208v 230v 208v
Min. Brch. Cir. Ampacity 2 30 27 45 40 55 48
Recmd-Max. Overload Protection (amps) 30 30 45 40 60 50
INDOOR COIL - Type PLATE FIN PLATE FIN PLATE FIN
Rows - F.P.I. 4 - 14 4 - 14 4 - 14
Face Area (sq. ft.) 2.43 2.43 2.43
Tube Size (in.) 3/8 3/8 3/8
Refrigerant Control FCCV FCCV FCCV
Drain Connection Size (In.) 3 3/4 PVC SLIP 3/4 PVC SLIP 3/4 PVC SLIP
DUCT CONNECTIONS See Outline Drawing See Outline Drawing See Outline Drawing
INDOOR FAN - Type Centrifugal Centrifugal Centrifugal
Diameter - Width (In.) 11 x 8 11 x 8 11 x 8
No. Used 1 1 1
Speeds (No.) 2 2 2
CFM vs. in. w.g. See Fan Performance Table See Fan Performance Table See Fan Performance Table
Motor HP - RPM 3/4 - 1125 3/4 - 1125 3/4 - 1125
F.L. Amps - L.R. Amps 4.0 / 9.1 4.0 / 9.1 4.0 / 9.1
FILTER — Furnished? Yes Yes Yes
Type Recommended Throwaway Throwaway Throwaway
Hi Vel. (No.-Size-Thk.) 1 - 18 x 20 - 1 In. 1 - 18 x 20 - 1 In. 1 - 18 x 20 - 1 In.
REFRIGERANT CONNECTIONS Brazed Brazed Brazed
Line Size - Gas (in.) 7/8 7/8 7/8
Line Size - Liquid (in.) 3/8 3/8 3/8
DIMENSIONS (in.) HXWXD HXWXD HXWXD
Crated (H X W X D) 42-1/2 x 23 x 20-3/8 42-1/2 x 23 x 20-3/8 42-1/2 x 23 x 20-3/8
Uncrated See Outline Drawing See Outline Drawing See Outline Drawing
WEIGHT (lbs.)
Shipping - Net 120 / 98 120 / 98 120 / 98
1 These Air Handlers are A.R.I certified with various Split System Air Conditioners and Heat Pumps (ARI STANDARD 210/240). Refer to the Split System Outdoor Unit Product Data Guides for performance data.
2 Minimum Circuit Ampacity includes Blower Motor Amps
3 3/4" Plastic Pipe (Ref.: ASTM 1785-76)

22-1753-01-0404 (EN) 7
General
Data

Product Specifications
MODEL 2TFE3025A1D05A 2TFE3025A1D08A 2TFE3025A1D10A
RATED VOLTS/PH/HZ. 208/230/1/60 208/230/1/60 208/230/1/60
RATINGS 1 See O.D. Specifications See O.D. Specifications See O.D. Specifications
HEATER CAPACITY (Volts) 240v 208v 240v 208v 240v 208v
HEATER CAPACITY (BTUH) 16400 12300 16400 12300 16400 12300
POWER CONNECTION 230v 208v 230v 208v 230v 208v
Min. Brch. Cir. Ampacity 2 30 27 46 40 56 49
Recmd-Max. Overload Protection (amps) 30 30 50 40 60 50
INDOOR COIL - Type PLATE FIN PLATE FIN PLATE FIN
Rows - F.P.I. 3 - 14 3 - 14 3 - 14
Face Area (sq. ft.) 2.43 2.43 2.43
Tube Size (in.) 3/8 3/8 3/8
Refrigerant Control NBTXV NBTXV NBTXV
Drain Connection Size (In.) 3 3/4 PVC SLIP 3/4 PVC SLIP 3/4 PVC SLIP
DUCT CONNECTIONS See Outline Drawing See Outline Drawing See Outline Drawing
INDOOR FAN - Type Centrifugal Centrifugal Centrifugal
Diameter - Width (In.) 10 x 8 10 x 8 10 x 8
No. Used 1 1 1
Speeds (No.) VARIABLE SPEED VARIABLE SPEED VARIABLE SPEED
CFM vs. in. w.g. See Fan Performance Table See Fan Performance Table See Fan Performance Table
Motor HP - RPM 1/2 1/2 1/2
F.L. Amps 4.3 4.3 4.3
FILTER — Furnished? Yes Yes Yes
Type Recommended Throwaway Throwaway Throwaway
Hi Vel. (No.-Size-Thk.) 1 - 18 x 20 - 1 In. 1 - 18 x 20 - 1 In. 1 - 18 x 20 - 1 In.
REFRIGERANT CONNECTIONS Brazed Brazed Brazed
Line Size - Gas (in.) 3/4 3/4 3/4
Line Size - Liquid (in.) 5/16 5/16 5/16
DIMENSIONS (in.) HXWXD HXWXD HXWXD
Crated (H X W X D) 40-1/2 x 23 x 20-3/8 40-1/2 x 23 x 20-3/8 40-1/2 x 23 x 20-3/8
Uncrated See Outline Drawing See Outline Drawing See Outline Drawing
WEIGHT (lbs.)
Shipping - Net 115 / 93 115 / 93 115 / 93
1 These Air Handlers are A.R.I certified with various Split System Air Conditioners and Heat Pumps (ARI STANDARD 210/240). Refer to the Split System Outdoor Unit Product Data Guides for performance data.
2 Minimum Circuit Ampacity includes Blower Motor Amps
3 3/4" Plastic Pipe (Ref.: ASTM 1785-76)

8 22-1753-01-0404 (EN)
Performance
Data

AIRFLOW PERFORMANCE AIRFLOW PERFORMANCE AIRFLOW PERFORMANCE AIRFLOW PERFORMANCE


2TFB4018A1D 2TFB4024A1D 2TFB4030A1D 2TFB4036A1D
CFM CFM CFM CFM
230 VOLTS 208 VOLTS 230 VOLTS 208 VOLTS 230 VOLTS 208 VOLTS 230 VOLTS 208 VOLTS
EXTERNAL EXTERNAL EXTERNAL EXTERNAL
STATIC STATIC STATIC STATIC
PRESSURE PRESSURE PRESSURE PRESSURE
(in. wg.) HI LO HI LO (in. wg.) HI LO HI LO (in. wg.) HI LO HI LO (in. wg.) HI LO HI LO
0.00 920 720 815 625 0.00 1075 890 1015 800 0.00 1140 1095 1100 1015 0.00 1285 1110 1258 1020

0.10 880 685 785 575 0.10 1030 850 975 755 0.10 1095 1050 1050 975 0.10 1242 1072 1215 982
0.20 830 640 735 530 0.20 975 800 935 715 0.20 1040 1000 995 925 0.20 1196 1029 1170 939

0.30 775 585 675 465 0.30 915 745 860 670 0.30 980 945 930 875 0.30 1150 979 1123 889

0.40 705 520 600 405 0.40 845 680 815 605 0.40 915 880 860 815 0.40 1101 927 1075 837
0.50 630 450 535 335 0.50 770 610 755 535 0.50 845 810 795 750 0.50 1041 883 1014 793

0.60 550 365 445 270 0.60 525 690 650 450 0.60 765 730 720 655 0.60 992 838 965 748

0.70 455 275 -- -- 0.70 600 435 520 360 0.70 685 650 605 550 0.70 943 792 917 702
NOTES: WITH WET COIL, FILTER & 10 KW ELECTRIC HEATER NOTES: WITH WET COIL, FILTER & 10 KW ELECTRIC HEATER NOTES: WITH WET COIL, FILTER & 10 KW ELECTRIC HEATER NOTES: WITH WET COIL, FILTER & 10 KW ELECTRIC HEATER
A800982P01 A800983P01 A800984P01 A801200P01

2TFE3025A1D AIR HANDLER AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE WITH FILTER

OUTDOOR DIP SWITCH SETTING EXTERNAL STATIC PRESSURE


UNIT SIZE AIRFLOW SETTING
(TONS) SW1 SW2 SW3 SW4 0.1 0.2 0.3 0.5 0.7 0.9

LOW
ON ON OFF ON CFM 525 525 500 450 445 440
(350 CFM/TON)

NORMAL
1.5 ON ON OFF OFF CFM 600 600 575 550 550 500
(400 CFM/TON)

HIGH
ON ON ON OFF CFM 650 650 650 650 625 575
(450 CFM/TON)

LOW
OFF ON OFF ON CFM 700 700 700 675 650 600
(350 CFM/TON)

NORMAL
2 OFF ON OFF OFF CFM 800 800 800 800 800 750
(400 CFM/TON)

HIGH
OFF ON ON OFF CFM 900 900 900 900 875 825
(450 CFM/TON)

LOW
ON OFF OFF ON CFM 850 850 850 875 850 850
(350 CFM/TON)

NORMAL
2.5 ON OFF OFF OFF CFM 1000 1000 1000 1000 950 850
(400 CFM/TON)

HIGH
ON OFF ON OFF CFM 1125 1125 1125 1125 1125 900
(450 CFM/TON)

LOW
OFF OFF OFF ON CFM 1050 1050 1050 1050 1000 850
(350 CFM/TON)

NORMAL
3** OFF OFF OFF OFF CFM 1200 1200 1200 1125 1050 950
(400 CFM/TON)

HIGH
OFF OFF ON OFF CFM 1300 1300 1250 1175 1100 1050
(450 CFM/TON)

NOTES:
1. ** Factory setting
2. At continuous Fan setting: Airflow values are approximately 50% of listed values.
3. With wet coil, filter in place, and 10KW electric heater.

22-1753-01-0404 (EN) 9
Performance
Data

AIRFLOW ADJUSTMENT INDOOR BLOWER TIMING


The ICM Fan Control controls the variable speed indoor blower.
If the airflow needs to be increased or decreased, see the The FAN-OFF period is set on the ICM Fan Control board by
Airflow Label on the air handler or the Blower Performance dip switches #5 and #6. The blower off-delay settings are as
Table in the Service Facts. Information on changing the speed follows:
of the blower motor for your specific outdoor model size is in the
COOLING OFF - DELAY OPTIONS
Blower Performance Table.
Blower speed changes are made on the ECM Fan Control. The NOMINAL
SWITCH SETTINGS SELECTION
ECM Fan control controls the variable speed motor. AIRFLOW

There is a bank of 8 dip switches (see Figure 1), located at the 5 - OFF 6 - OFF NONE SAME
upper part of the board. The dip switches work in pairs to match
the airflow for the outdoor unit size (tons), cooling airflow 5 - ON 6 - OFF 1.5 MINUTES 100% *
adjustment, cooling off delay options, and heating airflow 5 - OFF 6 - ON 3 MINUTES 50%
adjustment. The switches appear as shown in Figure 2.
5 - ON 6 - ON ENHANCED** 50 - 100%

1 * - This setting is equivalent to the BAY24X045 relay benefit

** - This ENHANCED MODE selection provides a ramping up


and ramping down of the blower speed to provide improved
comfort, quietness, and potential energy savings. The graph
shows the ramping process.

100% if necessary

80%
FAN OPERATION (CFM)

Dehumidify
Warm Air Heating
50% 50%

Fast Coil Cooling


Fast Coil Heating Efficiency

2
OFF OFF

COOLING HEATING FAN OFF AUXILIARY as required


AIRFLOW DELAY HEAT SPEEDS 1 7.5 3
minute minutes minutes

DIP SWITCHES (AS SHIPPED)

10 22-1753-01-0404 (EN)
Electrical
Data

2TFB4018,24,30,36A1D05

NOTES:

1. FOR 200V OPERATION SWAP RED HIGH VOLTAGE TRANSFORMER LEAD AND
INSULATED CAP ON 200V CENTER TRANSFORMER TERMINAL.

2. FOR REPLACEMENT FUSE, USE 5.0 AMP AUTOMOTIVE STYLE FOR ALL MODELS.

200 - 230 VOLT 60 HZ


1 PH POWER SUPPLY
PER LOCAL CODE

2TFB4018,24,30,36A1D08, D10

NOTES:

1. FOR 200V OPERATION SWAP RED HIGH VOLTAGE TRANSFORMER LEAD AND
INSULATED CAP ON 200V CENTER TRANSFORMER TERMINAL.

200 - 230 VOLT 60 HZ 2. FOR REPLACEMENT FUSE, USE 5.0 AMP AUTOMOTIVE STYLE FOR ALL MODELS.
1 PH POWER SUPPLY
PER LOCAL CODE

22-1753-01-0404 (EN) 11
Electrical
Data

2TFE3025A1D05

2TFE3025A1D08, D10

NOTES:

1. FOR 200V OPERATION SWAP RED HIGH VOLTAGE TRANSFORMER LEAD AND
INSULATED CAP ON 200V CENTER TRANSFORMER TERMINAL.

2. FOR REPLACEMENT FUSE, USE 5.0 AMP AUTOMOTIVE STYLE FOR ALL MODELS.

200 - 230 VOLT 60 HZ


1 PH POWER SUPPLY
PER LOCAL CODE

12 22-1753-01-0404 (EN)
Refrigerant
Circuit

Refrigerant Circuit Drawing for 2TFB4018,24,30 Air Handlers

From Drawing D800930 Sheet 1 Rev 4

Refrigerant Circuit Drawing for 2TFB4036 Air Handlers

From Drawing D801091G01

22-1753-01-0404 (EN) 13
Refrigerant
Circuit

Refrigerant Circuit Drawing for 2TFE3025 Air Handler

From Drawing D800930 Sheet 2 Rev 4

14 22-1753-01-0404 (EN)
22-1753-01-0404 (EN)

2TFB / 2TFE Outline Drawing


(All dimensions are in inches)

Dimensions
15

From Drawing D800913P01 Rev 5


P.I.

Trane
A business of
American Standard Companies Trane has a policy of continuous product and product data improvement and it reserves the right to change
www.trane.com design and specifications without notice.

You might also like