Ground Loops
Almost all cases of noise can be traced directly to improperly, thus creating balanced equipment that is
ground loops, grounding or lack thereof. It is important not immune to the cabling’s noise currents. This is one
to understand the mechanism that causes grounding reason for the bad reputation sometimes given to bal-
noise in order to effectively eliminate it. Each compo- anced interconnect.
nent of a sound system produces its own ground in- A second reason for balanced interconnect’s bad
ternally. This ground is usually called the audio signal reputation comes from those who think connecting
ground. Connecting devices together with the inter- unbalanced equipment into “superior” balanced equip-
connecting cables can tie the signal grounds of the two ment should improve things. Sorry. Balanced inter-
units together in one place through the conductors in connect is not compatible with unbalanced. The small
the cable. Ground loops occur when the grounds of the physical nature and short cable runs of completely
two units are also tied together in another place: via unbalanced systems (home audio) also contain these
the third wire in the line cord, by tying the metal chas- ground loop noise currents. However, the currents in
sis together through the rack rails, etc. These situations unbalanced systems never get large enough to affect
create a circuit through which current may flow in a the audio to the point where it is a nuisance. Mixing
closed “loop” from one unit’s ground out to a second balanced and unbalanced equipment, however, is an
unit and back to the first. It is not simply the presence entirely different story, since balanced and unbalanced
of this current that creates the hum—it is when this interconnect are truly not compatible. The rest of this
current flows through a unit’s audio signal ground that note shows several recommended implementations for
creates the hum. In fact, even without a ground loop, a all of these interconnection schemes.
little noise current always flows through every inter- The potential or voltage which pushes these noise
connecting cable (i.e., it is impossible to eliminate these currents through the circuit is developed between the
currents entirely). The mere presence of this ground independent grounds of the two or more units in the
loop current is no cause for alarm if your system uses system. The impedance of this circuit is low, and even
properly implemented and completely balanced inter- though the voltage is low, the current is high, thanks to
connects, which are excellent at rejecting ground loop Mr. Ohm, without whose help we wouldn’t have these
and other noise currents. Balanced interconnect was problems. It would take a very high resolution ohm
developed to be immune to these noise currents, which meter to measure the impedance of the steel chassis or
can never be entirely eliminated. What makes a ground the rack rails. We’re talking thousandths of an ohm. So
loop current annoying is when the audio signal is af- trying to measure this stuff won’t necessarily help you.
fected. Unfortunately, many manufacturers of balanced We just thought we’d warn you.
audio equipment design the internal grounding system
+ +
RED RED
BLACK 2-CONDUCTOR SHIELDED CABLE BLACK
– –
SHIELD SHIELD
G G
RED RED
T T
BLACK 2-CONDUCTOR SHIELDED CABLE BLACK
R SHIELD SHIELD R
S S
NOT CONNECTED
COMMON (WRONG) PRACTICE RECOMMENDED PRACTICE AT CHASSIS
(PLASTIC JACK)
(+) CASE (+) TRANSFORMER
CASE OPTIONAL
2 2 1/4” 2 CASE LUG MAY
3 (–) 3 (–) TIP-SLEEVE CONNECT TO
3 CHASSIS
1 1 1 (NOT REQUIRED)
FEMALE MALE
RED RED
2 2
BLACK 2-CONDUCTOR SHIELDED CABLE BLACK
C 3 3
SHIELD SHIELD
1 1
TEST
WIRE
Interconnection-5
To Input
CABLE
CONNECTORS
MALE ¼" BALANCED ¼" OR 3.5mm UNBALANCED RCA BALANCED
BALANCED XLR TRS (TIP-RING-SLEEVE) UNBALANCED EUROBLOCK
TS (TIP-SLEEVE)
+ to +
FEMALE BALANCED XLR
(NOT A TRANSFORMER,
NOR A CROSS-COUPLED
1 2 3 B
4 B
– to –
SHIELD ONLY
TO EUROBLOCK
OUTPUT STAGE)
+ to +
FEMALE BALANCED XLR
(EITHER A TRANSFORMER
OR A CROSS-COUPLED
1 2 5 6 – to –
SHIELD ONLY
TO EUROBLOCK
OUTPUT STAGE)
+ to +
¼” BALANCED TRS
(NOT A TRANSFORMER, 7 8 9 B
10 B
– to –
SHIELD ONLY
TO EUROBLOCK
From Output
NOR A CROSS-COUPLED
OUTPUT STAGE)
+ to +
¼” BALANCED TRS
(EITHER A TRANSFORMER
OR A CROSS-COUPLED
7 8 11 12 – to –
SHIELD ONLY
TO EUROBLOCK
OUTPUT STAGE)
21 22 11 12
+ to +
– to –
¼” FLOATING UNBALANCED GROUND to GROUND
A A
TRS (TIP-RING-SLEEVE)
(SLEEVE IN UNIT = NC)
¼” OR 3.5 mm
UNBALANCED
TS (TIP-SLEEVE)
13 14 15 A
16 A
23
UNBALANCED RCA
(TIP-SLEEVE) 17 18 19 A
20 A
23
+ to + + to + + to +
BALANCED
EUROBLOCK
– to –
SHIELD ONLY
TO XLR PIN 1
– to –
SHIELD ONLY
TO TRS SLEEVE
24 24 – to –
GROUND to GROUND
Figure 4. Interconnect chart for locating correct cable assemblies on the following pages.
Note: (A) This configuration uses an “off-the-shelf” cable.
Note: (B) This configuration causes a 6 dB signal loss. Compensate by “turning the system up” 6 dB.
Interconnection-6
FEMALE MALE
1=NC RED RED 1=SHIELD
1 2=RED
3=BLACK
2
C 3 BLACK
SHIELD
2-CONDUCTOR SHIELDED CABLE BLACK
N/C
2
3 2=RED
3=BLACK
1 1
FEMALE
1=NC RED RED T=RED
2 2=RED
3=BLACK
2
C 3 BLACK
SHIELD
2-CONDUCTOR SHIELDED CABLE BLACK
N/C
R=BLACK
S=SHIELD
1
FEMALE
1=SHIELD RED
3 2=RED
B 3=NC
2
C 3
SHIELD
1-CONDUCTOR SHIELDED CABLE
RED
SHIELD
T=RED
S=SHIELD
1
FEMALE
1=SHIELD RED
4 2=RED
B 3=NC
2
C 3
SHIELD
1-CONDUCTOR SHIELDED CABLE
RED
SHIELD
T=RED
S=SHIELD
1
FEMALE
1=SHIELD RED RED
5 2=RED
3=BLACK
2
C 3 BLACK
SHIELD
2-CONDUCTOR SHIELDED CABLE BLACK T=RED
1 S=BLACK
CROSS-COUPLED OUTPUT ONLY: CONNECT PIN 1 TO PIN 3 AT THIS END
AND SET GROUND LIFT SWITCH TO ‘GROUNDED’ (IF PRESENT).
From Output
FEMALE
1=SHIELD RED RED
6 2=RED
2
BLACK 2-CONDUCTOR SHIELDED CABLE BLACK T=RED
To Input
C 3
3=BLACK 1 SHIELD S=BLACK
CROSS-COUPLED OUTPUT ONLY: CONNECT PIN 1 TO PIN 3 AT THIS END
AND SET GROUND LIFT SWITCH TO ‘GROUNDED’ (IF PRESENT).
MALE
T=RED RED RED 1=SHIELD
7 R=BLACK
S=NC
BLACK
SHIELD
2-CONDUCTOR SHIELDED CABLE BLACK
2
3
2=RED
3=BLACK
N/C 1
T=RED
9B R=NC
S=SHIELD
RED
SHIELD
1-CONDUCTOR SHIELDED CABLE
RED
SHIELD
T=RED
S=BLACK
T=RED
10B R=NC
S=SHIELD
RED
SHIELD
1-CONDUCTOR SHIELDED CABLE
RED
SHIELD
T=RED
S=SHIELD
Interconnection-7
MALE
RED RED 1=SHIELD
13 T=RED
S=BLACK
BLACK
N/C
2-CONDUCTOR SHIELDED CABLE BLACK
SHIELD
2
3 2=RED
3=BLACK
1
15A T=RED
S=SHIELD
RED
SHIELD
1-CONDUCTOR SHIELDED CABLE
RED
SHIELD
T=RED
S=SHIELD
RED
16A T=RED
S=SHIELD SHIELD
1-CONDUCTOR SHIELDED CABLE
RED
SHIELD
T=RED
S=SHIELD
MALE
RED RED 1=SHIELD
2
17 T=RED BLACK 2-CONDUCTOR SHIELDED CABLE BLACK
3 2=RED
From Output
To Input
RED RED T=RED
18 T=RED
S=BLACK
BLACK 2-CONDUCTOR SHIELDED CABLE BLACK
SHIELD
R=BLACK
S=SHIELD
19A T=RED
S=SHIELD
RED
SHIELD
1-CONDUCTOR SHIELDED CABLE RED
SHIELD
T=RED
S=SHIELD
20A T=RED
S=SHIELD
RED
SHIELD
1-CONDUCTOR SHIELDED CABLE
RED
SHIELD
T=RED
S=SHIELD
MALE
T=RED RED RED 1=SHIELD
21 R=BLACK
A S=SHIELD
BLACK
SHIELD
2-CONDUCTOR SHIELDED CABLE BLACK
SHIELD
2
3 2=RED
3=BLACK
1
©Rane Corporation 10802 47th Ave. W., Mukilteo WA 98275-5098 USA TEL 425-355-6000 FAX 425-347-7757 WEB www.rane.com