You are on page 1of 61

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

CHAPTER 1 PREFACE
1.1 INTRODUCTION

A robot is defined as a re-programmable multi-functional manipulator. In simple words, it is a mechanical system which consists of sensing and executing organs; controlled by an electronic brain that can perform a number of operations independently within a confined space. The robot movements are controlled by a user and future movements can be stored in micro-controller, and thus its job assignments can be changed by reprogramming micro-controller. The Metal and Chemical Detecting Robot movements are controlled by user using Radio frequency signals like moving right, left, back, and front. Once if the robot detects any metallic material in front of it, then it starts generating sound signals or triggers buzzer unit and indicates metallic or chemical bomb is detected. The RF Based Metal Detecting Robot project has two parts: Transmitter and Receiver. The Transmitter part consists of RF (Radio Frequency) or IR (Infrared Rays), Interface Module and RC5 Transmitter. The commands are sent by the user and the intended software. These commands are in RC5 [Recommended Code] form, and are transmitted to the Robotic Vehicle through Infra-Red Packets. The Receiver part receives the RC5 coded signals and fed to PIC micro-controller chip. This Microcontroller decodes RC5 codes back to original commands and executes them as needed. Here the decoded signals are properly routed using switching circuit. The output of the switching circuit controls the movement of the Robotic Vehicle. If the command says to turn Right/ Left or move Forward/Reverse it does so by activating the respective motor, and thus fulfilling the need. The Receiver part thus has two motors: to and fro movement and Left/Right turn and object/obstacle detection along with image capturing using Wireless CAM.

1.2 MOTIVATION The law enforcement community needs a low-cost robot that can reduce or eliminate the danger for a bomb technician who must inspect, x-ray, and disrupt an explosive device preferably in its original
SVCP- Electronics & Telecommunication Engineering 1

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

place or may be sometimes need to be relocated. Sensors and tools must be placed close to a suspected device. Approaching a device can be dangerous, since many points along the path to the bomb may be booby-trapped. Even when a bomb technician uses great care in inspecting or handling an explosive device, the possibility exists that the bomber is waiting nearby to remotely detonate the device or a secondary device when the bomb technician is within range. An effective Bomb Disposal Unit (BDU) can reduce or eliminate the risk of potentially deadly scenarios and allow a bomb technician to focus on disabling the device. The same feature can be extended to be used in the war fields where the army might be required to go into the hostile situations where mines could have been
laid. In such situations in case the human beings are allowed to go traverse over them there will be a major loss in the human resource. Thus a need arises to diffuse or locate a mine from a distance. Even if a BDU cannot diffuse a device, it can still relay information to aid in selecting tools and procedures before a technician approaches a device. In addition, events recorded by a robots camera can provide evidence for future forensic purposes.

1.3 CONTRIBUTIONS OF THIS REPORT The use of cutting edge Wi-Fi technology allowing better, faster & undisputed signal allowing better communication and control. Its highly efficient for military & security purposes in bomb related fields. It has greater area of effect & range ability. It detects metal bombs & chemical bombs. Camera allows robot to access areas which are humanly hard to scale, in time of emergencies.

1.4 ORGANIZATION OF THIS REPORT

Chapter1 gives the basic introduction & the motivation behind the project.Chapter2 consists of literature survey of the projects & some similar exemplary projects in the same field. Chapter3 deals with the detection methods, as well as the detailed description of the transmitter & receiver module. Chapter4 gives a detailed description of the power supply unit & other important components used in the robot. Chapter5 explains the basic design & operation of the whole circutary.Finally,chapter6 is the conclusion we derived from this project.

CHAPTER 2
SVCP- Electronics & Telecommunication Engineering 2

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

LITERATURE SURVEY

2.1 INTRODUCTION Tele-robotics is the area of robotics concerned with the control of robots from a distance, chiefly using wireless connections (like Wi-Fi, Bluetooth, the Deep Space Network, and similar), "tethered" connections, or the Internet. It is a combination of two major subfields, tele-operation and telepresence. Even though this is the first of its kind prototype bot, similar bots applicable in this field have been made.

The First Remote Control Vehicle / Precision Guided Weapon, this propeller-driven radio controlled boat, built by Nikola Tesla in 1898, is the original prototype of all modern-day uninhabited aerial vehicles and precision guided weapons. In fact, all remotely operated vehicles in air, land or sea. Powered by lead-acid batteries and an electric drive motor, the vessel was designed to be maneuvered alongside a target using instructions received from a wireless remote control transmitter. Once in position, a command would be sent to detonate an explosive charge contained within the boats forward compartment. The weapon's guidance system incorporated a secure communications link between the pilot's controller and the surface-running torpedo in an effort to assure that control could be maintained even in the presence of electronic countermeasures. To learn more about Tesla's system for secure wireless communications and his pioneering Implementation of the electronic logic-gate circuit read Nikola Tesla Guided Weapons & Computer Technology, Tesla Presents Series Part 3, with commentary by Leland Anderson. Use of Remote Controlled Vehicles During World War II :During World War II in the European Theater the U.S. Air Force experimented with three basic forms radio control guided weapons. In each case, the weapon would be directed to its target by a crew member on a control plane. The first weapon was essentially a standard bomb fitted with steering controls. The next evolution involved the fitting of a bomb to a glider airframe, one version, the GB-4 having a TV camera to assist the controller with targeting. The third class of guided weapon was the remote controlled B-17. It's known that Germany deployed a number of more advanced guided strike weapons that saw combat before either the V-1 or V-2. They were the radio-controlled Henschel's Hs 293A and Ruhrstahl's SD1400X, known as "Fritz X," both air-launched, primarily against ships at sea. 2.2 EXAMPLES: Some of the present day bots are as follows:
SVCP- Electronics & Telecommunication Engineering 3

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

1) The Spiral Track Autonomous Robot (STAR): A team of engineers developed STAR at the

Lawrence Livermore National Laboratory in California. Speed: 133 feet per minute when moving sideways, 20 feet per minute when moving forward or backwards. STAR can be controlled remotely or can control itself autonomously. During remote operation, an operator controls the robot using a wireless data link attached to a laptop computer. The operator can view the surrounding environment via a wireless video. In the autonomous mode, STAR is given start and end points and can then plan its own path independently. Other features: STAR can be equipped with video cameras, microphones and infrared sensors. It can also employ radiation and gas sensors. The robot can also be equipped with Micropower Impulse Radar (MIR) land mine detection technology (which was also developed at the Lawrence Livermore National Laboratory).
2) RF Controlled Robot with Metal Detector and Wireless image and voice transmission (Model

Path Finder): Developed by Trevelyan, J. Dept. of Mech. & Mater. Eng., Western Australia Univ., Nedlands, WA;

CHAPTER 3 DETECTION METHODS

SVCP- Electronics & Telecommunication Engineering 4

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

3.1 RADIO FREQUENCY CIRCUIT TECHNIQUES

Radio must surely be one of the most fascinating aspects of electronics. This part of explanation provides a brief introduction to radio communication before describing the circuitry of RF receivers and transmitters. The aim has been to provide the user with sufficient information to what his or her appetite for a subject which has a broad appeal to a large number of dedicated enthusiasts all over the world.

Ultra high frequency, UHF


30 MH z high 30 M Hz

Frequ ency 3 G H z

Wavel ength 1 0 c m TV bands 1V/V 1 m FM broadcasting 1 0 SW m broadcastin 1 g 0 0 MW m broadcasting 1 Km 1 broadcasting LW 0 K m

Very frequency, VHF

High frequency, HF
3

M H Medium z frequency, MF 300 KHz Low frequency, LF 30 K Hz

Figure 3.1 The Radio Frequency Spectrum

SVCP- Electronics & Telecommunication Engineering 5

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

Radio Frequency Circuit Techniques Radio must surely be one of the most fascinating aspects of electronics. This part of explanation provides a brief introduction to radio communication before describing the circuitry of RF receivers and transmitters. The aim has been to provide the user with sufficient information to what his or her appetite for a subject which has a broad appeal to a large number of dedicated enthusiasts all over the world.

3.2 Radio Frequency Signals: Radio frequency signals are generally understood to occupy a frequency range, which extends from a few tens of kilohertz to several hundred giga-hertz. The lowest part of radio frequency range, which is of practical use (below 30 kHz), is only suitable for narrow-band communications. At this frequency, signals propagate as ground waves (following the curvature of the earth) over very long distance. At the other extreme, the highest frequency range, which is of practical importance, extends above 30GHz. At these microwave frequencies, considerable bandwidths are available (sufficient to transmit many television channel using point-to-point links or to permit very high definition radar systems) and signals tend to propagate strictly along line-of-sight paths. At other frequencies, signals may propagate by various means, including reflection from ionized layers in the ionosphere. At frequencies between 3MHz and 30MHz, for example, ionospheric propagation regularly permits intercontinental broadcasting and communications using simple equipment within the scope of the enthusiastic radio amateur and short-wave listener. For convenience, the radio frequency spectrum is divided into a number of bands, each spanning a decade of frequency. The use to which each frequency range is put depends upon a number of factors, paramount amongst which is the propagation characteristic within the band concerned. Other factors, which need to be taken into account, include the efficiency of practical aerial system in the range concerned and the bandwidth available. It is also worth noting that, although it may appear from Figure A that a great deal of the radio frequency spectrum is not used, it should be stressed that competition for frequency space is fierce. Frequency allocations are, therefore, ratified by international agreement and the various user services carefully safeguard their own areas of the spectrum.

3.3 Frequency and wavelength:


SVCP- Electronics & Telecommunication Engineering 6

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

Radio waves propagate in air (or space) at the speed of light (300 million meters per second). The velocity of propagation[v], wavelength [ ] and frequency [f] of a radio wave are related by the equation: V = f = 3 X 108 m/s This equation can be arranged to make f or the subject, as follows: F = 3 X 108/ Hz and = 3 X 108 / fm As an example, a signal at a frequency of 1 MHz will have a wavelength of 300 m whereas a signal at a frequency of 10 MHz will have a wavelength of 30m.

3.4 Modulation In order to convey information using a radio frequency carrier, the signal information must be superimposed or modulated onto the carrier. Modulation is the name given to the process of changing a particular property of the carrier wave in sympathy with the instantaneous voltage (or current) signal. The most commonly used methods of modulation are amplitude modulation (AM) and frequency modulation (FM). In the former case, the carrier amplitude (its peak voltage) varies according to the voltage, at any instant, of the modulating signal. In the latter case, the carrier frequency is varied in accordance with the voltage, at any instant, of the modulating signal. Figure B shows the effect of amplitude and frequency modulating a sinusoidal carrier (note that the modulating signal is, in the case, also sinusoidal). In practice, many more cycles of the radio frequency carrier would occur in the time span of the cycle of the modulating signal.

SVCP- Electronics & Telecommunication Engineering 7

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

Figure 3.2 Amplitude & Frequency Modulation The term angle modulation is the generic term encompassing both frequency modulation and phase modulation. Frequency modulation involves operating directly upon the frequency determining elements of an oscillator stage (e.g. by means of a variable capacitance diode placed across the oscillator-tuned circuit or connected in series with a quartz crystal).

Phase modulation, on the other hand, acts indirectly by changing the phase of the signal in a subsequent stage (e.g. by means of a variable capacitance diode acting in a phase shifting circuit).

If the modulating signal (audio) is correctly tailored prior to its application to the phase modulated stage, the end result is identical to that of frequency modulation. The reason for this is that, in a true FM system, the deviation produced is the same for all modulating signals of equal amplitude (i.e. the amount frequency deviation is independent of the frequency of the modulating signal). In a phasemodulated system, on other hand, the amount of frequency deviation is proportional to both modulating signal amplitude and modulating signal frequency. Thus in a phase modulated system without audio tailoring, a modulation signal of 2 kHz will produce twice as much frequency deviation as an equal amplitude modulating signal of 1 kHz. The desired audio response required to produce FM, therefore, is one, which rolls off the frequency response by half for each doubling of frequency (equivalent to 6-dB per octave roll-off). This can be easily achieved using a simple R-C low-pass filter.
SVCP- Electronics & Telecommunication Engineering 8

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

3.5 Demodulation Demodulation is the reverse of modulation and is the means by which the signal information is recovered from the modulated carrier. Demodulation is achieved by means of a demodulator consists of a reconstructed version of the original signal information present at the input of the modulator stage within the transmitter. Figure C shows the simplified block schematic of a simple radio communication system comprising on AM transmitter and a tuned radio frequency (TRF) receiver. Within the transmitter, the carrier wave (of constant frequency) is generated by means of a radio frequency oscillator stage. In order to ensure that the carrier is both accurate and within in frequency, this stage would normally employ a quartz crystal within its frequency generating circuitry. The output of the modulator (a modulated carrier) is amplified before outputting to the aerial system. The output is usually carefully filtered to remove any spurious signals (harmonics) which may be present and which may otherwise cause interference to other services. At the receiver, the signal produced by the receiving aerial is a weak copy of the transmitted signal (its level is usually measured in a V). Also present will be countless other signals at different
M i c .

AF am plifi er RF Osc . RF Mod ulato r am plifi er

RF am plifi er

Demo dulato r

AF am plifi er

Figure.3.3-Radio Communication System frequencies (and some with appreciably larger amplitude than the desired signal). These unwanted signals must be rejected by the receivers radio frequency tuned circuits if they are no to cause problems in later stages.
SVCP- Electronics & Telecommunication Engineering 9

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

3.6 TRANSMITTER MODULE A) RF TRANSMITTER The RF transmitter is built around the ASIC and common passive and active components, which are very easy to obtain from the material shelf. The circuit works on Very High Frequency band with wide covering range. The Carrier frequency is 147 MHz and Data frequencies are 17 MHz, 19 MHz, 22 MHz & 25 MHz. It should be noted that ASIC or Application Specific Integrated Circuit is proprietary product and data sheet or pin details or working principles are not readily available to the user. ASIC: Application Specific Integrated Circuit [ASIC] is another option for embedded hardware developers. ASIC needs to be custom-built for specific applications, so it is costly. If the embedded system being designed is a consumer item and is likely to be sold in large quantities, then going the ASIC route is the best option, as it considerably reduces the cost of each unit. In addition, size and power consumption will also be reduced. As the chip count (the number of chips on the system) decreases, reliability increases. If the embedded system is for the mass market, such as those used in CD players, toys, and mobile devices, cost is a major consideration. Choosing the right processor, memory devices, and peripherals to meet the functionality and performance requirements while keeping the cost reasonable is of critical importance. In such cases, the designers will develop an Application Specific Integrated Circuit or an Application Specific Microprocessor to reduce the hardware components and hence the cost. Typically, a developer first creates a prototype by writing the software for a general-purpose processor, and subsequently develops an ASIC to reduce the cost. Oscillator: An electronic device that generates sinusoidal oscillations of desired frequency is known as a sinusoidal oscillator. Although we speak of an oscillator as generating a frequency, it should be noted that it does not create energy, but merely acts as an energy converter. It receives D.C. energy and changes it into A.C energy of desired frequency. The frequency of oscillations depends upon the constants of the device. A circuit which produces electrical oscillations of any desired frequency is known as an oscillatory circuit or tank circuit. A simple oscillatory circuit consists of a capacitor (C) and inductance coil (L) in parallel. This electrical system can produce electrical oscillations of frequency determined by the values of L and C. The sequence of charge and discharge results in alternating motion of electrons or

SVCP- Electronics & Telecommunication Engineering 10

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

an oscillating current. The energy is alternately stored in the electric field of the capacitor and the magnetic field of the inductance coil. This intercharge of energy between L and C is repeated over and again resulting in the production of oscillations. In order to obtain continuous undamped a.c. output from the tank circuit, it is necessary to supply the correct amount of power to the circuit. The most practical way to do this is to supply D.C. power to some device which should convert it to necessary a.c. power for supply to the tank circuit. This can be achieved by employing a transistor circuit. Because of its ability to amplify, a transistor is very efficient energy converter i.e. it converts D.C. power to A.C. power. If the damped oscillations in the tank circuit are applied to the base of transistor, it will result in an amplified reproduction of oscillations in the collector circuit. Because of this amplification more energy is available in the collector circuit than in the base circuit. If a part of this collector-circuit energy is feedback by some means to the base circuit in proper phase to aid the oscillations in the tank circuit, then its losses will be overcome and continuous undamped oscillations will occur. Hartley Oscillator is very popular and is commonly used as a local oscillator in radio receivers. It has two main advantages viz., adaptability to a wide range of frequencies and is easy to tune. The RF transmitter is built around the common passive and active components, which are very is to obtain from the material shelf. The circuit works on Very High Frequency band with wide covering range.

B) CIRCUIT DESCRIPTION: The ASIC Transmitter IC has four inputs and only one output pin. The four inputs are for the frequency range of 17 KHz, 19 KHz, 22 KHz and 25 KHz and four switches are provided for each range. When any one switch is selected, that frequency is added to the Transmitter circuit as data frequency and transmitted in the air. The Crystal X1 with two coupling capacitor provides the working oscillator frequency to the circuit. The Capacitors C6 and C7 are to stabilize the crystal oscillator frequency.

SVCP- Electronics & Telecommunication Engineering 11

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

C) PARTS LIST SEMICONDUCTORS: IC T1 T2 RESISTORS: R1 & R2 R3 & R6 R4 R5 CAPACITORS: C1, C2 C3 & C7 C4 C5 & C6 MISCELLANEOUS: X1 S1 to S4 L1 L2 1.44 MHz Crystal ON/OFF SWITCHES RF Coil 200mH Aerial or Telescopic Antenna 1 4 1 1 0.001 Pico Farad Capacitor 0.022 Pico Farad Capacitor 4.7 Pico Farad Capacitor 0.01 Micro Farad Capacitor 2 2 1 2 2.7 K Ohm Watt 330 K Ohm Watt 1 K Ohm Watt 47 K Ohm Watt 2 2 1 1 ASIC BC 547 NPN Transistor BF 494 NPN Transistor 1 1 1

The ASIC output is added to the transmitter circuits oscillator transistor T1s base. The data frequency is added with carrier frequency 147 MHz and aired for transmitting purpose. The transistor T1 is heart of the Hartely Oscillator and oscillates at carrier frequency of 147 MHz along with tuned circuit formed by coil L1 and capacitor C4. The Data frequency is fed to T1 on base through resistors R4 and R5. Capacitors C1 and C3 and for stabilizing the tuned circuit along with resistor R3.
SVCP- Electronics & Telecommunication Engineering 12

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

To increase the range of the circuit, transmitting signals must be strong enough to travel the long distance [i.e., upto 100 meters in this prototype]. So the generated signals are made strong by amplifying to certain level with the help of Transistor T2 and associated circuit. The Radio frequency thus generated is fed to pre-amplifier transistor T2 on base terminal. The resistor R6 provides the bias voltage to T2 and capacitors C5 & C7 removes the noise and harmonics present in the circuit. The antenna coil L2 transmits the radio frequency in the air.

SVCP- Electronics & Telecommunication Engineering 13

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

+ V cc 17 KHz S1 19KHz S2 22 KHz S3 25 KHz S4 ASIC C 7 R4 R5 C1 X 1 C 6 C3 C4 R3 33 0K


L 1

L 2

C 5

C 7

R 6 C 2 0 . 0 0 1

RT 21

T 2

R 1

2 K 7

G n d

FIGURE.3.4-CIRCUIT DIAGRAM OF WI-FI TRANSMITTER


SVCP- Electronics & Telecommunication Engineering 14

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

3.7 RECEIVER MODULE A) RF RECEIVER


This circuit is built around the ASIC i.e., Application Specific Integrated Circuit, hence less circuitry is observed. The Radio Frequency tuned circuit has 147 M Hz carrier frequency with four options viz., 17Khz, 19Khz, 22KHz and 25KHz. The transmitted signals are received on coil L1 which acts as receiver antenna. The oscillator transistor removes the received signals from 147MHz carrier frequency and fed to ASIC. The tank circuit formed by C1 and L1 gives the carrier frequency range. The current limiting resistor R1 and bypass capacitor C5 stabilizes the oscillator. The resistor R2, R3 and R4 provide the biasing voltage to the oscillator transistor T1. Capacitors C2 and C3 are there to bypass the noise and harmonics present in the received signals. Through coupling capacitor C7 output of the RF Receiver is fed to ASIC. The ASIC manipulates the received signal and gives out four channels as output viz., 17KHz, 19KHz, 22KHz and 25KHz. Each channel is amplified by pre-amplifier transistor T2 along with bias resistor R9. The output of the pre-amplifier transistor is fed to relay driver stage to activate the respective relay ON. The Darlington pair T3 and T4 are arranged in driver stage to drive the low impedance relay.

PARTS LIST

SVCP- Electronics & Telecommunication Engineering 15

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

SEMICONDUCTORS: IC T1 T2 T3&T4 RESISTORS: R1 & R2 R3 & R6 R4 R5 R7 R8 R9 CAPACITORS: C1, C2 C3 & C7 C4 C5 & C6 L1 0.001 Pico Farad Capacitor 0.022 Pico Farad Capacitor 4.7 Pico Farad Capacitor 0.01 Micro Farad Capacitor RF Coil 200mH 2 2 1 2 1 270 K Ohm Watt 220 Ohm Watt 2.2 K Ohm Watt 2.2 M Ohm Watt 10 K Ohm Watt 100 Ohm Watt 560 Ohm Watt 2 2 1 1 1 4 4 ASIC BC 547 NPN Transistor BF 494 NPN Transistor BC 548 NPN Transistor 1 1 4 8

SVCP- Electronics & Telecommunication Engineering 16

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

SVCP- Electronics & Telecommunication Engineering 17

+ V

R 6 R R 2 R 7 7 6 5 4 3 2 1 T 2 R 9 T 3 T 4

C 1 C 2

L 1

R 3 R 1

C C 3 T 1 C 8 9

ASIC
1 1 1 1 1 + V

R R 9

C R 4

C 4

R 5

T 2

T 3 T 4

SVCP- Electronics & Telecommunication Engineering FIGURE.3.5-CIRCUIT DIAGRAM OF WI-FI RECEIVER 16

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

A relay is an electrically operated switch. Many relays use an electromagnet to operate a switching mechanism mechanically, but other operating principles are also used. Relays are used where it is necessary to control a circuit by a low-power signal (with complete electrical isolation between control and controlled circuits), or where several circuits must be controlled by one signal. The first relays were used in long distance telegraph circuits, repeating the signal coming in from one circuit and re-transmitting it to another. Relays were used extensively in telephone exchanges and early computers to perform logical operations. A type of relay that can handle the high power required to directly drive an electric motor is called a contactor. Solid-state relays control power circuits with no moving parts, instead using a semiconductor device to perform switching. Relays with calibrated operating characteristics and sometimes multiple operating coils are used to protect electrical circuits from overload or faults; in modern electric power systems these functions are performed by digital instruments still called "protective relays". 3.8 Magnetic Field Sensor (MG-BTA or MG-DIN)

Figure.3.6 Hall effect sensor The Magnetic Field Sensor can be used for a variety of interesting experiments involving magnetic fields. Measure and study the Earths magnetic field. Determine the direction of magnetic north. Study the magnetic field near a permanent magnet.
SVCP- Electronics & Telecommunication Engineering 19

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

Measure the field near a current-carrying wire. Measure the field at the opening of a solenoid. The Magnetic Field Sensor is designed for use with the following interfaces: Vernier LabPro (for use with computers, TI graphing calculators, or Palm OS handhelds) Texas Instruments CBL 2 or original CBL System Universal Lab Interface (ULI) Serial Box Interface

Using the Magnetic Field Sensor with a Computer This sensor can be used with a LabPro, ULI, or Serial Box Interface. Here is the general procedure to follow when using the Magnetic Field Sensor with a computer: 1. Connect the Magnetic Field Sensor to any of the analog ports on LabPro (in most cases, Channel 1 is used) or to a ULI or SBI. 2. Start the Logger Pro or Logger Lite software on a computer. 3. You are now ready to collect data. Logger Pro or Logger Lite will identify the Magnetic Field Sensor and load a calibration. Click and begin collecting data. 4. If you are using Logger Pro software, an alternative to Step 3 is to open an experiment file in the Logger Pro Probes & Sensors folder.

Using the Magnetic Field Sensor with TI Handhelds This sensor can be used with a TI graphing calculator and any of the following lab interfaces: LabPro, CBL 2, or CBL. Here is the general procedure to follow when using the Magnetic Field Sensor with a graphing calculator: 1. Load a data-collection program onto your calculator: LabPro or CBL 2Use the DataMate program. This program can be transferred directly from LabPro or CBL to the TI graphing calculator. Use the calculator-to-calculator link cable to connect the two devices. Put the calculator into the Receive mode, and then press the Transfer button on the interface. Original CBLIf you are using the sensor with the original CBL, we recommend the PHYSICS program. This program is available free on our web site at www.vernier.com. Load the program into a calculator using TIConnect software or TI-GRAPH LINK. 2. Use the calculator-to-calculator link cable to connect the interface to the TI graphing calculator using the I/O ports located on each unit. Be sure to push both plugs in firmly.
SVCP- Electronics & Telecommunication Engineering 20

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

3. Connect the Magnetic Field Sensor to any of the analog ports on the interface. In most cases, Channel 1 is used. 4. Start the data-collection program, and you are ready to collect data.

Using the Magnetic Field Sensor with Palm OS Handhelds 1. This sensor can be used with a Palm OS handheld and the LabPro. 2. Connect the Palm OS handheld, LabPro, and the Magnetic Field Sensor. 3. Start Data Pro. 4. Tap New, or choose New from the Data Pro menu. Tap New again. The Magnetic Field Sensor will be identified automatically. 5. You are now ready to collect data.

3.9 How the Magnetic Field Sensor Works The sensor uses a Hall-effect transducer. It produces a voltage that is linear with magnetic field. The sensor measures the component of the magnetic field that is perpendicular to the flat sensor covered with black heat-shrink tubing. The maximum output occurs when the white dot on the sensor points toward a magnetic south pole. When no magnetic field is present, the sensor should read about 2 volts. This is called the offset voltage. A magnetic field will cause the voltage to increase or decrease, depending on the direction of the field. The minimum voltage is 0 volts and the maximum is 4 volts. If the offset voltage is set incorrectly, or if the magnetic field is beyond the range of the sensor, the voltage will reach one of these limits.

Figure.3.7-Magenetic field of earth

SVCP- Electronics & Telecommunication Engineering 21

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

The switch on the box is used to select the amplification. The low amplification is used to measure relatively strong magnetic fields around permanent magnets and electromagnets. Each volt represents 32 gauss (3.2 10-3 tesla). The range of the sensor is 64 gauss or 6.4 10-3 tesla. The high amplification is used mainly to measure the magnetic field of the Earth and very weak fields. It can be used for other magnets, but the sensor must remain in one position so that the reading is not affected by the background field of the Earth. It is 20 times more sensitive than the low amplification. Each volt represents 1.6 gauss (1.6 10-4 tesla). The range of the sensor is 3.2 gauss or 3.2 10-4 tesla. If the sensor tube is held vertically and rotated until the maximum voltage is found, magnetic north will be perpendicular to the sensor in the direction of the white dot. The magnetic inclination in your area can be found by holding the tube so that the white dot is facing north, and rotating the sensor end of the tube down until the voltage reaches a maximum. The angle of the tube from vertical is the magnetic inclination. Note that the north pole of a freely suspended magnet points north, since the magnetic pole of the Earth in the northern hemisphere is a south magnetic pole.You should not have to perform a new calibration when using the Magnetic Field Sensor in the classroom. We have set the sensor to match our stored calibration before shipping it. You can simply use the appropriate calibration file that is stored in your data-collection software from Vernier. Stored Calibration Values for the Magnetic Field Sensor Low amplification in gauss slope = 32.25 gauss/V intercept = 80.625 gauss High amplification in gauss slope = 1.6 gauss/V intercept = 3.2 gauss Low amplification in millitesla slope = 3.225 mT/V intercept = 8.063 mT High amplification in millitesla slope = 0.160 mT/V intercept = 0.320 mT It is not practical to calibrate the Magnetic Field Sensor without reference to a known source of magnetic field. It is useful, however, to zero the Magnetic Field Sensor. Position the sensor, and zero it using your data-collection software. Now, move the magnetic field source, and not the sensor, to explore the spatial variations of the field. Moving the sensor will upset the zero since the background magnetic field in lab probably varies with position.

SVCP- Electronics & Telecommunication Engineering 22

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

CHAPTER 4 POWER SUPPLY UNIT & OTHER COMPONENTS

4.1 POWER SUPPLY UNIT The circuit needs two different voltages, +5V & +12V, to work. These dual voltages are supplied by this specially designed power supply. The power supply, unsung hero of every electronic circuit, plays very important role in smooth running of the connected circuit. The main object of this power supply is, as the name itself implies, to deliver the required amount of stabilized and pure power to the circuit. Every typical power supply contains the following sections: 1. Step-down Transformer: The conventional supply, which is generally available to the user, is 230V AC. It is necessary to step down the mains supply to the desired level. This is achieved by using suitably rated step-down transformer. While designing the power supply, it is necessary to go for little higher rating transformer than the required one. The reason for this is, for proper working of the regulator IC (say KIA 7805) it needs at least 2.5V more than the expected output voltage 2. Rectifier stage: Then the step-downed Alternating Current is converted into Direct Current. This rectification is achieved by using passive components such as diodes. If the power supply is designed for low voltage/current drawing loads/circuits (say +5V), it is sufficient to employ full-wave rectifier with centre-tap transformer as a power PIV rating is taken into consideration.
KIA 78x x Ser ies

source. While choosing the diodes the

12 3 3. Filter stage: But this rectified output contains some percentage of superimposed A.C. ripples. So to filter these A.C. components filter stage is built around the rectifier stage. The cheap, reliable, simple and effective filtering for low current drawing loads (say upto 50 mA) is done by using shunt capacitors. This electrolytic capacitor has polarities, take care while connecting the circuit.
SVCP- Electronics & Telecommunication Engineering 23

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

4. Voltage Regulation: The filtered D.C. output is not stable. It varies in accordance with the fluctuations in mains supply or varying load current. This variation of load current is observed due to voltage drop in transformer windings, rectifier and filter circuit. These variations in D.C. output voltage may cause inaccurate or erratic operation or even malfunctioning of many electronic circuits. For example, the circuit boards which are implanted by CMOS or TTL ICs. The stabilization of D.C. output is achieved by using the three terminal voltage regulator IC. This regulator IC comes in two flavors: 78xx for positive voltage output and 79xx for negative voltage output. For example 7805 gives +5V output and 7905 gives -5V stabilized output. These regulator ICs have in-built short-circuit protection and auto-thermal cutout provisions. If the load current is very high the IC needs heat sink to dissipate the internally generated power.

Circuit Description: A d.c. power supply which maintains the output voltage constant irrespective of a.c. mains fluctuations or load variations is known as regulated D.C. power supply. It is also referred as full-wave regulated power supply as it uses four diodes in bridge fashion with the transformer.

D 9 V

+ 1 2 + V 5 V

2 230 3 0 V AC A C D 2 1

C 2

C 3

C 4

Figure.4.1-Circuit Diagram of Full Wave Regulated Power Supply

This laboratory power supply offers excellent line and load regulation and output voltages of +5V & +12 V at output currents up to one amp.

SVCP- Electronics & Telecommunication Engineering 24

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

Parts List: SEMICONDUCTORS IC1 IC2 D1& D2 CAPACITORS C1 C2 to C4 MISCELLANEOUS X1 230V AC Pri,14-0-14 1Amp Sec Transformer 1 1000 f/25V Electrolytic 0.1F Ceramic Disc type 1 3 7812 Regulator IC 7805 Regulator IC 1N4007 Rectifier Diodes
IC1 781 IC2 7805

1 1 2

1. Step-down Transformer: The transformer rating is 230V AC at Primary and 12-0-12V, 1Ampers across secondary winding. This transformer has a capability to deliver a current of 1Ampere, which is more than enough to drive any electronic circuit or varying load. The 12VAC appearing across the secondary is the RMS value of the waveform and the peak value would be 12 x 1.414 = 16.8 volts. This value limits our choice of rectifier diode as 1N4007, which is having PIV rating more than 16Volts. 2. Rectifier Stage: The two diodes D1 & D2 are connected across the secondary winding of the transformer as a full-wave rectifier. During the positive half-cycle of secondary voltage, the end A of the secondary winding becomes positive and end B negative. This makes the diode D1 forward biased and diode D2 reverse biased. Therefore diode D1 conducts while diode D2 does not. During the negative half-cycle, end A of the secondary winding becomes negative and end B positive. Therefore diode D2 conducts while diode D1 does not. Note that current across the centre tap terminal is in the same direction for both half-cycles of input A.C. voltage. Therefore, pulsating D.C. is obtained at point C with respect to Ground. 3. Filter Stage: Here Capacitor C1 is used for filtering purpose and connected across the rectifier output. It filters the a.c. components present in the rectified D.C. and gives steady D.C. voltage. As the rectifier voltage increases, it charges the capacitor and also supplies current to the load. When capacitor is charged to the peak value of the rectifier voltage, rectifier voltage starts to decrease. As the next voltage peak immediately recharges the capacitor, the discharge period is of very small
SVCP- Electronics & Telecommunication Engineering 25

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

duration. Due to this continuous charge-discharge-recharge cycle very little ripple is observed in the filtered output. Moreover, output voltage is higher as it remains substantially near the peak value of rectifier output voltage. This phenomenon is also explained in other form as: the shunt capacitor offers a low reactance path to the A.C. components of current and open circuit to D.C. component. During positive half cycle the capacitor stores energy in the form of electrostatic field. During negative half cycle, the filter capacitor releases stored energy to the load. 4. Voltage Regulation Stage: Across the point D and Ground there is rectified and filtered D.C. In the present circuit KIA 7812 three terminal voltage regulator IC is used to get +12V and KIA 7805 voltage regulator IC is used to get +5V regulated d.c. output. In the three terminals, pin 1 is input i.e., rectified & filtered D.C. is connected to this pin. Pin 2 is common pin and is grounded. The pin 3 gives the stabilized D.C. output to the load. The circuit shows two more decoupling capacitors C2 & C3, which provides ground path to the high frequency noise signals. Across the point E and F with respect to ground +5V & +12V stabilized or regulated D.C output is measured, which can be connected to the required circuit.

4.2 BUFFER, DRIVER & SWITCHING MODULE When the user programs the schedule for the automation using GUI [Graphical User Interface] software, it actually sends 5-bit control signals to the circuit. The present circuit provides interfacing with the Microcontroller and the controlling circuitry. This circuit takes the 5-bit control signal, isolates the Microcontroller from this circuitry, boosts control signals for required level and finally fed to the driver section to actuate relay. These five relays in turn sends RC5 coded commands with respect to their relay position.

HEX BUFFER / CONVERTER [NON-INVERTER] IC 4050: Buffers does not affect the logical state of a digital signal (i.e. logic 1 input results into logic 1 output where as logic 0 input results into logic 0 output). Buffers are normally used to provide extra current drive at the output, but can also be used to regularise the logic present at an interface. And Inverters are used to complement the logical state (i.e. logic 1 input results into logic 0 output and vice versa). Also Inverters are used to provide extra current drive and, like buffers, are used in interfacing applications. This 16-pin DIL packaged IC 4050 acts as Buffer as-well-as a Converter. The input signals may be of 2.5 to 5V digital TTL compatible or DC analogue the IC gives 5V constant signal output. The IC acts as buffer and provides isolation to the main circuit from varying input signals. The working voltage of IC is 4 to 16
SVCP- Electronics & Telecommunication Engineering 26

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

Volts and propagation delay is 30 nanoseconds. It consumes 0.01 mill Watt power with noise immunity of 3.7 V and toggle speed of 3 Megahertz.

ULN 2004: Since the digital outputs of the some circuits cannot sink much current, they are not capable of driving relays directly. So, high-voltage high-current Darlington arrays are designed for interfacing low-level logic circuitry and multiple peripheral power loads. The series ULN2000A/L ICs drive seven relays with continuous load current ratings to 600mA for each input. At an appropriate duty cycle depending on ambient temperature and number of drivers turned ON simultaneously, typical power loads totalling over 260W [400mA x 7, 95V] can be controlled. Typical loads include relays, solenoids, stepping motors, magnetic print hammers, multiplexed LED and incandescent displays, and heaters. These Darlington arrays are furnished in 16-pin dual in-line plastic packages (suffix A) and 16-lead surface-mountable SOICs (suffix L). All devices are pinned with outputs opposite inputs to facilitate ease of circuit board layout.

IC ULN 2004 1 1 6 1 5 1 4 1 3 1 2 1 1 1 0 9 V c c

2 3 4 5 6 7 8

Figure.4.2-Pin layout IC ULN 2004

SVCP- Electronics & Telecommunication Engineering 27

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

The input of ULN 2004 is TTL-compatible open-collector outputs. As each of these outputs can sink a maximum collector current of 500 mA, miniature MICROCONTROLLER relays can be easily driven. No additional free-wheeling clamp diode is required to be connected across the relay since each of the outputs has inbuilt free-wheeling diodes. The Series ULN20x4A/L features series input resistors for operation directly from 6 to 15V CMOS or PMOS logic outputs. 1N4148 signal diode: Signal diodes are used to process information (electrical signals) in circuits, so they are only required to pass small currents of up to 100mA. General purpose signal diodes such as the 1N4148 are made from silicon and have a forward voltage drop of 0.7V.

SVCP- Electronics & Telecommunication Engineering 28

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

I C
+ 5 V
1 3 5 7 9 1 1 1 4 8

I C 1
2 4 6 1 0 1 2 1 5

2
9 1 2 3 4 5 6

R 6D R 61 D 0 1 0 1
6 1 5 1 4 1 3 1 2 1 1 1 0

C O M1

C O M2

C O M3

C O M4

+ 1 C2 O M-V 5

R L 1

N / C

R L 2

N / C

R L 3

N / C

R L 4

N / C

R L 5

N / C

Commands from MICROCO NTROLLE R

D1 TO D5 G n d

7 8

R1 TO R5

Figure.4.3-CIRCUIT DIAGRAM OF BUFFER, DRIVER & SWITCHING STAGE


SVCP- Electronics & Telecommunication Engineering 29

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

Parts List: SEMICONDUCTORS IC1 IC2 RESISTORS R1 to R5 R6 to R10 DIODES D1to D5 D6 to D10 MISCELLANEOUS RL1-RL5 12 V, 700 Ohm DPDT Reed Relays 5 1N4148 SIGNAL Diodes Red Indicator LEDs 5 5 220 Ohm Watt Carbon Resistors 2.2 K Ohm Watt Carbon Resistors 5 5 4050 HEX BUFFER/CONVERTER(NON-INVERTER) 2004 DARLINGTON ARRY 1 1

Circuit Description: The Hex Buffer/Inverter IC1s working voltage of +5V is applied at pin-1 and five control signals are applied at input pins 3, 5, 7, 9 & 11. Thus the signal supplying circuit [i.e. MICROCONTROLLER] is isolated from this Buffer & Driver circuit. Further the grounding resistors R1 to R5 prevents the abnormal voltage levels passing inside the IC1. The buffered outputs are acquired at pins 2, 4, 6, 10, & 12. Thus the varying input is further stabilized and fed to signal diodes [D1 to D5]. As the load is inductive, there is a chance of producing back e.m.f. So to cope with this back e.m.f, signal diodes are used. But this signal level is not strong enough to drive the low impedance relay. So, IC2 Darlington driver is used. Its working voltage is +12 V and only five input/output pins are used. The output signal from the Darlington driver IC is strong enough to actuate five relays. These relays with +12V working voltage can be used to produce five command signals with RC5 format. The N/O [Normally Open] contact of each relay produces one command signal with the help of RC5 Transmitter Circuit. The five relays activation with their corresponding command signal production is tabulated as below:

RELAY

COMMAND

COMMAND

SVCP- Electronics & Telecommunication Engineering 30

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

RL1 RL2 RL3 RL4 RL5

NUMBER COM-1 COM-2 COM-3 COM-4 COM-5

SIGNAL TURN LEFT TURN RIGHT MOVE BACKWARD MOVE FORWARD SWITCH ON/OFF THE SUCKING DEVICE

CHAPTER 5 BASIC DESIGN & OPERATION

SVCP- Electronics & Telecommunication Engineering 31

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

5.1 BASIC CIRCUITRY A simple electromagnetic relay consists of a coil of wire surrounding a soft iron core, an iron yoke which provides a low reluctance path for magnetic flux, a movable iron armature, and one or more sets of contacts (there are two in the relay pictured). The armature is hinged to the yoke and mechanically linked to one or more sets of moving contacts. It is held in place by a spring so that when the relay is de-energized there is an air gap in the magnetic circuit. In this condition, one of the two sets of contacts in the relay pictured is closed, and the other set is open. Other relays may have more or fewer sets of contacts depending on their function. The relay in the picture also has a wire connecting the armature to the yoke. This ensures continuity of the circuit between the moving contacts on the armature, and the circuit track on the printed circuit board (PCB) via the yoke, which is soldered to the PCB. When an electric current is passed through the coil it generates a magnetic field that attracts the armature, and the consequent movement of the movable contact(s) either makes or breaks (depending upon construction) a connection with a fixed contact. If the set of contacts was closed when the relay was de-energized, then the movement opens the contacts and breaks the connection, and vice versa if the contacts were open. When the current to the coil is switched off, the armature is returned by a force, approximately half as strong as the magnetic force, to its relaxed position. Usually this force is provided by a spring, but gravity is also used commonly in industrial motor starters. Most relays are manufactured to operate quickly. In a low-voltage application this reduces noise; in a high voltage or current application it reduces arcing. When the coil is energized with direct current, a diode is often placed across the coil to dissipate the energy from the collapsing magnetic field at deactivation, which would otherwise generate a voltage spike dangerous to semiconductor circuit components. Some automotive relays include a diode inside the relay case. Alternatively, a contact protection network consisting of a capacitor and resistor in series (snubber circuit) may absorb the surge. If the coil is designed to be energized with alternating current (AC), a small copper "shading ring" can be crimped to the end of the solenoid, creating a small out-of-phase current which increases the minimum pull on the armature during the AC cycle.[1] A solid-state relay uses a thyristor or other solid-state switching device, activated by the control signal, to switch the controlled load, instead of a solenoid. An optocoupler (a light-emitting diode (LED) coupled with a photo transistor) can be used to isolate control and controlled circuits.
SVCP- Electronics & Telecommunication Engineering 32

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

5.2 Types of Relays: A latching relay has two relaxed states (bistable). These are also called "impulse", "keep", or "stay" relays. When the current is switched off, the relay remains in its last state. This is achieved with a solenoid operating a ratchet and cam mechanism, or by having two opposing coils with an overcenter spring or permanent magnet to hold the armature and contacts in position while the coil is relaxed, or with a remanent core. In the ratchet and cam example, the first pulse to the coil turns the relay on and the second pulse turns it off. In the two coil example, a pulse to one coil turns the relay on and a pulse to the opposite coil turns the relay off. This type of relay has the advantage that it consumes power only for an instant, while it is being switched, and it retains its last setting across a power outage. A remanent core latching relay requires a current pulse of opposite polarity to make it change state.

1.Reed relay
A reed relay is a reed switch enclosed in a solenoid. The switch has a set of contacts inside an evacuated or inert gas-filled glass tube which protects the contacts against atmospheric corrosion; the contacts are made of magnetic material that makes them move under the influence of the field of the enclosing solenoid. Reed relays can switch faster than larger relays, require only little power from the control circuit, but have low switching current and voltage ratings. 2.Mercury-wetted relay A mercury-wetted reed relay is a form of reed relay in which the contacts are wetted with mercury. Such relays are used to switch low-voltage signals (one volt or less) where the mercury reduces the contact resistance and associated voltage drop, for low-current signals where surface contamination may make for a poor contact, or for high-speed applications where the mercury eliminates contact bounce. Mercury wetted relays are position-sensitive and must be mounted vertically to work properly. Because of the toxicity and expense of liquid mercury, these relays are now rarely used.. 3.Polarized relay A polarized relay placed the armature between the poles of a permanent magnet to increase sensitivity. Polarized relays were used in middle 20th Century telephone exchanges to detect faint pulses and correct telegraphic distortion. The poles were on screws, so a technician could first

SVCP- Electronics & Telecommunication Engineering 33

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

adjust them for maximum sensitivity and then apply a bias spring to set the critical current that would operate the relay.

4.Machine tool relay


A machine tool relay is a type standardized for industrial control of machine tools, transfer machines, and other sequential control. They are characterized by a large number of contacts (sometimes extendable in the field) which are easily converted from normally-open to normallyclosed status, easily replaceable coils, and a form factor that allows compactly installing many relays in a control panel. Although such relays once were the backbone of automation in such industries as automobile assembly, the programmable logic controller (PLC) mostly displaced the machine tool relay from sequential control applications.

5.Contactor relay
A contactor is a very heavy-duty relay used for switching electric motors and lighting loads, although contactors are not generally called relays. Continuous current ratings for common contactors range from 10 amps to several hundred amps. High-current contacts are made with alloys containing silver. The unavoidable arcing causes the contacts to oxidize; however, silver oxide is still a good conductor.[2] Such devices are often used for motor starters. A motor starter is a contactor with overload protection devices attached. The overload sensing devices are a form of heat operated relay where a coil heats a bi-metal strip, or where a solder pot melts, releasing a spring to operate auxiliary contacts. These auxiliary contacts are in series with the coil. If the overload senses excess current in the load, the coil is de-energized. Contactor relays can be extremely loud to operate, making them unfit for use where noise is a chief concern.

6.Solid-state relay
A solid state relay (SSR) is a solid state electronic component that provides a similar function to an electromechanical relay but does not have any moving components, increasing long-term reliability. With early SSR's, the tradeoff came from the fact that every transistor has a small voltage drop across it. This voltage drop limited the amount of current a given SSR could handle. As transistors improved, higher current SSR's, able to handle 100 to 1,200 Amperes, have become

SVCP- Electronics & Telecommunication Engineering 34

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

commercially available. Compared to electromagnetic relays, they may be falsely triggered by transients.

7.Solid state contactor relay


A solid state contactor is a heavy-duty solid state relay, including the necessary heat sink, used for switching electric heaters, small electric motors and lighting loads; where frequent on/off cycles are required. There are no moving parts to wear out and there is no contact bounce due to vibration. They are activated by AC control signals or DC control signals from Programmable logic controller (PLCs), PCs, Transistor-transistor logic (TTL) sources, or other microprocessor and microcontroller controls.

8.Buchholz relay
A Buchholz relay is a safety device sensing the accumulation of gas in large oil-filled transformers, which will alarm on slow accumulation of gas or shut down the transformer if gas is produced rapidly in the transformer oil.

9. Forced-guided contacts relay


A forced-guided contacts relay has relay contacts that are mechanically linked together, so that when the relay coil is energized or de-energized, all of the linked contacts move together. If one set of contacts in the relay becomes immobilized, no other contact of the same relay will be able to move. The function of forced-guided contacts is to enable the safety circuit to check the status of the relay. Forced-guided contacts are also known as "positive-guided contacts", "captive contacts", "locked contacts", or "safety relays".

10.Overload protection relay


Electric motors need overcurrent protection to prevent damage from over-loading the motor, or to protect against short circuits in connecting cables or internal faults in the motor windings. [3] One type of electric motor overload protection relay is operated by a heating element in series with the electric motor. The heat generated by the motor current heats a bimetallic strip or melts solder, releasing a spring to operate contacts. Where the overload relay is exposed to the same environment as the motor, a useful though crude compensation for motor ambient temperature is provided.
SVCP- Electronics & Telecommunication Engineering 35

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

Figure.5.1-Pole and throw Circuit symbols of relays.


(C denotes the common terminal in SPDT and DPDT types.)

Since relays are switches, the terminology applied to switches is also applied to relays. A relay will switch one or more poles, each of whose contacts can be thrown by energizing the coil in one of three ways:

Normally-open (NO) contacts connect the circuit when the relay is activated; the circuit is Normally-closed (NC) contacts disconnect the circuit when the relay is activated; the circuit is Change-over (CO), or double-throw (DT), contacts control two circuits: one normally-open

disconnected when the relay is inactive. It is also called a Form A contact or "make" contact. connected when the relay is inactive. It is also called a Form B contact or "break" contact. contact and one normally-closed contact with a common terminal. It is also called a Form C contact or "transfer" contact ("break before make"). If this type of contact utilizes a "make before break" functionality, then it is called a Form D contact. The following designations are commonly encountered:

SPST Single Pole Single Throw. These have two terminals which can be connected or

disconnected. Including two for the coil, such a relay has four terminals in total. It is ambiguous

SVCP- Electronics & Telecommunication Engineering 36

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

whether the pole is normally open or normally closed. The terminology "SPNO" and "SPNC" is sometimes used to resolve the ambiguity.

SPDT Single Pole Double Throw. A common terminal connects to either of two others. DPST Double Pole Single Throw. These have two pairs of terminals. Equivalent to two

Including two for the coil, such a relay has five terminals in total.

SPST switches or relays actuated by a single coil. Including two for the coil, such a relay has six terminals in total. The poles may be Form A or Form B (or one of each).

DPDT Double Pole Double Throw. These have two rows of change-over terminals.

Equivalent to two SPDT switches or relays actuated by a single coil. Such a relay has eight terminals, including the coil. The "S" or "D" may be replaced with a number, indicating multiple switches connected to a single actuator. For example 4PDT indicates a four pole double throw relay (with 14 terminals). EN 50005 are among applicable standards for relay terminal numbering; a typical EN 50005compliant SPDT relay's terminals would be numbered 11, 12, 14, A1 and A2 for the C, NC, NO, and coil connections, respectively.

Applications of Relays: Relays are used to and for, control a high-voltage circuit with a low-voltage signal, as in some types of modems or audio amplifiers. Control a high-current circuit with a low-current signal, as in the starter solenoid of an automobile. Detect and isolate faults on transmission and distribution lines by opening and closing circuit breakers (protection relays). Isolate the controlling circuit from the controlled circuit when the two are at different potentials, for example when controlling a mains-powered device from a low-voltage switch. The latter is often applied to control office lighting as the low voltage wires are easily installed in partitions, which may be often moved as needs change. They may also be controlled by room occupancy detectors in an effort to conserve energy. Logic functions. For example, the boolean AND function is realized by connecting normally open relay contacts in series, the OR function by connecting normally open contacts in parallel. The change-over or Form C contacts perform the XOR (exclusive or) function. Similar functions for NAND and NOR are accomplished using normally closed contacts. The Ladder programming language is often used for designing relay logic networks. Early computing before

SVCP- Electronics & Telecommunication Engineering 37

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

vacuum tubes and transistors, relays were used as logical elements in digital computers. Because relays are much more resistant than semiconductors to nuclear radiation, they are widely used in safety-critical logic, such as the control panels of radioactive waste-handling machinery. Time delay functions. Relays can be modified to delay opening or delay closing a set of contacts. A very short (a fraction of a second) delay would use a copper disk between the armature and moving blade assembly. Current flowing in the disk maintains magnetic field for a short time, lengthening release time. For a slightly longer (up to a minute) delay, a dashpot is used. A dashpot is a piston filled with fluid that is allowed to escape slowly. The time period can be varied by increasing or decreasing the flow rate. For longer time periods, a mechanical clockwork timer is installed. Relay application considerations Selection of an appropriate relay for a particular application requires evaluation of many different factors:

Number and type of contacts normally open, normally closed, (double-throw) Contact sequence "Make before Break" or "Break before Make". For example, the old style

telephone exchanges required Make-before-break so that the connection didn't get dropped while dialling the number.

Rating of contacts small relays switch a few amperes, large contactors are rated for up to Voltage rating of contacts typical control relays rated 300 VAC or 600 VAC, automotive Coil voltage machine-tool relays usually 24 VAC, 120 or 250 VAC, relays for switchgear Coil current Package/enclosure open, touch-safe, double-voltage for isolation between circuits, explosion Assembly Some relays feature a sticker that keeps the enclosure sealed to allow PCB post Mounting sockets, plug board, rail mount, panel mount, through-panel mount, enclosure for Switching time where high speed is required "Dry" contacts when switching very low level signals, special contact materials may be

3000 amperes, alternating or direct current

types to 50 VDC, special high-voltage relays to about 15 000 V

may have 125 V or 250 VDC coils, "sensitive" relays operate on a few milliamperes

proof, outdoor, oil and splash resistant, washable for printed circuit board assembly

soldering cleaning, which is removed once assembly is complete.

mounting on walls or equipment


needed such as gold-plated contacts


SVCP- Electronics & Telecommunication Engineering 38

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

Contact protection suppress arcing in very inductive circuits Coil protection suppress the surge voltage produced when switching the coil current Isolation between coil circuit and contacts Aerospace or radiation-resistant testing, special quality assurance Expected mechanical loads due to acceleration some relays used in aerospace applications Accessories such as timers, auxiliary contacts, pilot lamps, test buttons Regulatory approvals Stray magnetic linkage between coils of adjacent relays on a printed circuit board.

are designed to function in shock loads of 50 g or more


Timer IC 555

SVCP- Electronics & Telecommunication Engineering 39

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

Figure.5.2- Pin configuration

The 555 timer is an extremely versatile integrated circuit which can be used to build lots of different circuits.

5.4 Astable circuits Astable circuits produce pulses. The circuit most people use to make a 555 astable looks like this:

SVCP- Electronics & Telecommunication Engineering 40

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

As you can see, the frequency, or repetition rate, of the output pulses is determined by the values of two resistors, R1 and R2 and by the timing capacitor, C. The design formula for the frequency of the pulses is:

The HIGH and LOW times of each pulse can be calculated from:

The duty cycle of the waveform, usually expressed as a percentage, is given by:

An alternative measurement of HIGH and LOW times is the mark space ratio:

SVCP- Electronics & Telecommunication Engineering 41

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

Before calculating a frequency, you should know that it is usual to make R1=1 k because this helps to give the output pulses a duty cycle close to 50%, that is, the HIGH and LOW times of the pulses are approximately equal. Remember that design formulae work in fundamental units. However, it is often more convenient to work with other combinations of units:

resistance

Capacitance

period

frequency

Hz

Hz

ms

kHz

With R values in M and C values in F, the frequency will be in Hz. Alternatively, with R values in k and C values in F, frequencies will be in kHz. Suppose you want to design a circuit to produce a frequency of approximately 1 kHz for an alarm application. What values of R1, R2 and C should you use? R1 should be 1k, as already explained. This leaves you with the task of selecting values for R2 and C. The best thing to do is to rearrange the design formula so that the R values are on the right hand side:

Now substitute for R1 and f :

SVCP- Electronics & Telecommunication Engineering 42

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

You are using R values in k and f values in kHz, so C values will be in F. To make further progress, you must choose a value for C. At the same time, it is important to remember that practical values for R2 are between 1 k and 1M. Suppose you choose C = 10 nF = 0.01 F:

that is:

and:

This is within the range of practical values and you can choose values from the E12 range of 68 k or 82 k. (The E12 range tells you which values of resistor are manufactured and easily available from suppliers.) A test circuit can be set up on prototype board, as follows:

SVCP- Electronics & Telecommunication Engineering 43

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

With the values of R1, R2 and C shown, the LED should flash at around 10 Hz. What happens if you replace R2 with an LDR or a thermistor? This gives an astable which changes frequency in response to light intensity, or with temperature.

Astable component selection With a little practice, it is quite easy to choose appropriate values for a 555 timer astable. To make things even easier, you might like to download the DOCTRONICS 555 timer component selection program.

The program works with Windows 95 and looks like this:


SVCP- Electronics & Telecommunication Engineering 44

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

More astables

SVCP- Electronics & Telecommunication Engineering 45

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

Extended duty cycle astable: An extremely useful variation of the standard astable circuit involves adding a diode in parallel with R2:

This simple addition has a dramatic effect on the behaviour of the circuit. The timing capacitor, C, is now filled only through R1 and emptied only through R2. The design equation for the output pulse frequency is:

HIGH and LOW times are calculated from:

With this circuit, the duty cycle can be any value you want. If R1 > R2, the duty cycle will be greater than 50% (equivalent to a mark space ratio of more than 1.0). On the other hand, if R2 > R1, the duty cycle will be less than 50% (mark space ratio less than 1.0). This version of the 555 astable is used in the cyclist/pedestrian safety lights project.
SVCP- Electronics & Telecommunication Engineering 46

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

Minimum component astable: This is a cheap and cheerful astable using just one resistor and one capacitor as the timing components:

Note that there is no connection to pin 7 and that R1 is linked to the output, pin 3. The design equation for the circuit is:

The HIGH and LOW times are supposed to be equal, giving a duty cycle of 50% (equivalent to a mark space ratio of 1.0).

However, if you build this circuit, it is probable that the HIGH time will be longer than the LOW time. (This happens because the maximum voltage reached by the output pulses is less than the power supply voltage.) Things will get worse if the output current increases.
SVCP- Electronics & Telecommunication Engineering 47

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

If you need an astable circuit which can be adjusted to give an accurate frequency, this circuit is not the one to choose. Diminishing frequency astable: The excitement and realism of electronic games, including roulette, can be increased using an astable circuit which is triggered to produce rapid pulses initially, but which then slows down and eventually stops altogether. It is easy to modify the basic 555 astable circuit to produce this result:

When the 'go' button is pressed, the 47 F capacitor in parallel with the timing network, R1, R2 and C, charges up very quickly through the 100 resistor. When the button is released, the astable continues to oscillate but the charge stored slowly leaks away, with the result that it takes longer and longer to charge up the timing capacitor. To trigger the next pulse, the voltage across C must increase to two thirds of the power supply voltage. After a while, the voltage across the 47 F drops below this value and the pulses stop. With the values shown, the initial frequency is about 100 Hz and the output pulses coast to a stop after around 40 seconds.

SVCP- Electronics & Telecommunication Engineering 48

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

The initial frequency can be calculated from the design equation for the basic 555 astable. To give a realistic coasting time, you should use large values for the resistors R1 and R2. The coasting time is determined by the 47 F capacitor. Experiment with different values until you get the effect you want. . RESET input If the RESET input, pin 4, is held HIGH, a 555 astable circuit functions as normal. However, if the RESET input is held LOW, output pulses are stopped. You can investigate this effect by connecting a switch/pull down resistor voltage divider to pin 4:

SVCP- Electronics & Telecommunication Engineering 49

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

Figure.5.3-Circuit on prototype board: Use the design formula, or the DOCTRONICS component selector program to calculate the frequency of pulses you would expect to obtain with this circuit. In an electronic die, provided the output pulses are fast enough, it is impossible to 'cheat' by holding down the button for a definite length of time. Think about how you could use this circuit together with a bistable as part of a burglar alarm. Under normal conditions, the output of the bistable is LOW and the astable is stopped. If the alarm is triggered, the output of the bistable goes HIGH and the pulses start, sounding the alarm.
.

Control voltage input: By applying a voltage to the CONTROL VOLTAGE input, pin 5, you can alter the timing characteristics of the device. In the astable mode, the control voltage can be varied from 1.7 V to the power supply voltage, producing an output frequency which can be higher or lower than the frequency set by the R1, R2, C timing network.

SVCP- Electronics & Telecommunication Engineering 50

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

The CONTROL VOLTAGE input can be used to build an astable with a frequency modulated output. In the circuit below, one astable is used to control the frequency of a second, giving a 'police siren' sound effect.

In most applications, the CONTROL VOLTAGE input is not used. It is usual to connect a 10 nF capacitor between pin 5 and 0 V to prevent interference. You don't need to do this in building a test circuit, but this 'bypass' or 'decoupling' capacitor should be included in your final circuit. . Monostable circuits A monostable circuit produces a single pulse when triggered. The two questions about monostables you immediately need to ask are:

How can the circuit be triggered to produce an output pulse? How is the duration, or period, of the output pulse determined?

The circuit used to make a 555 timer monostable is:

SVCP- Electronics & Telecommunication Engineering 51

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

As you can see, the trigger input is held HIGH by the 10 k pull up resistor and is pulsed LOW when the trigger switch is pressed. The circuit is triggered by a falling edge, that is, by a sudden transition from HIGH to LOW. The trigger pulse, produced by pressing the button, must be of shorter duration than the intended output pulse. The period, of the output pulse can be calculated from the design equation: ,

Remember again about compatible measurement units:

resistance

Capacitance

period

SVCP- Electronics & Telecommunication Engineering 52

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

ms

With R1 = 1 M and C = 1 F, the output pulse will last for 1.1 s. You can build a test version of the 555 monostable as follows:

SVCP- Electronics & Telecommunication Engineering 53

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

By clicking on the monostable tab, the 555 component selection program can be used to investigate the effect of different R1 and C values:

More about triggering

SVCP- Electronics & Telecommunication Engineering 54

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

For a simple 555 monostable, the trigger pulse must be shorter than the output pulse. Sometimes you want to trigger the monostable from a longer pulse:

The trigger network detects the falling edge at the end of each Vin pulse, producing a short 'spike' which triggers the monostable at the appropriate time. The period of the monostable pulse is shorter than the period of the Vin pulses.
SVCP- Electronics & Telecommunication Engineering 55

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

If you want to trigger the monostable from a rising edge, you need to add a transistor NOT gate to the trigger circuit:

If you build these circuits, it is interesting to investigate the action of the trigger network using an oscilloscope.
.

555 as a transducer driver A transducer is a subsystem which converts energy from one form into another, where one of the forms is electrical. In an output transducer, for example, electrical energy can be converted into light, sound, or movement. The output of a 555 timer can deliver more than 100 mA of current. This means that output transducers including buzzers, filament lamps, loudspeakers and small motors can be connected directly to the output of the 555, pin 3. You can use the 555 as a transducer driver, that is, as an electronic switch which turns the transducer ON or OFF:

SVCP- Electronics & Telecommunication Engineering 56

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

This circuit has an inverting Schmitt trigger action. The 'inverting' part of this description means that when Vin is LOW, the output is HIGH, and when Vin is HIGH, the output is LOW. In a 'Schmitt trigger' circuit there are two different switching thresholds. If Vin is slowly increased starting from 0 V, the output voltage snaps from HIGH to LOW when Vin reaches a level equal to
2

/3 of the power supply voltage. Once this level has been exceeded, decreasing Vin does not affect

the output until Vin drops below 1/3 of the power supply voltage. (If an input change in one direction produces a different result from a change in the opposite direction, the circuit is said to show hysteresis.) If a filament lamp is connected between the positive power supply rail and the output, as shown above, current flows through the lamp when the output voltage is LOW. In other words, the lamp lights when the input voltage is HIGH. If you connect the lamp between the output and 0 V, the circuit will still work, but the lamp will light when the input voltage is LOW:

SVCP- Electronics & Telecommunication Engineering 57

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

Note that, in both versions of the circuit pins 2 and 6 are joined together. The circuit can be simplified by omitting the 10 nF bypass capacitor, and will continue to work when the RESET input, pin 4 is left unconnected. Some people are very fond of this circuit and use it whenever a transducer driver is required. However, with a HIGH/LOW digital input signal the same result can be achieved more obviously and at lower cost using a transistor switch circuit.

SVCP- Electronics & Telecommunication Engineering 58

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

CHAPTER 6 FUTURE DEVELOPMENT


1. Using GPS we can control the movements of Robot in remote areas. 2. In the same Robotic model we can implement fire detecting and extinguisher. 3. On further research in this field, the Wi-Fi technology can be implemented & used to replace present communication methods viz. Bluetooth, infrared etc 4. This technology holds great scope in automation & military applications

CHAPTER 7
SVCP- Electronics & Telecommunication Engineering 59

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

CONCLUSION

The experimental work was carried to improve the design of robust wireless mobile bomb disposal unit that would be capable of reaching close to the objects of threat and the real scenario can be observed through an onboard video camera which can send back video feedback to the observatory. From this experimental work we can conclude that use of Wi-Fi technology holds future robotics allowing better control & range ability. The Metal And Chemical Detecting Robot movements are controlled by user using Radio frequency signals like moving right, left, back, and front. Once if the robot detects any metallic material in front of it, then it starts generating sound signals or triggers buzzer unit and indicates metallic or chemical bomb is detected.

REFERENCES: -www.telerobotics.com
SVCP- Electronics & Telecommunication Engineering 60

Diploma (E&TC)

Wi-Fi metal & chemical bomb detector robot

-www.learnaboutrobots.com - http://ranier.hq.nasa.gov/telerobotics_page/telerobotics.shtm -Robotics:A reference guide to new technology by Rafael H. Bordini (page 16) -Counter Terrorism Equipment by Ivn V. hog & Ray Hutchkins (page 144) - P. Pounds, R. Maloy, P. Hynes and J. Roberts, Design of a Four-Rotor Aerial Robot, Australian Conference on Robotics and Automation,2002 - A. Y. Ng, A. Coates, M. Diel, V. Ganapathi, J. Schulte, B. Tse, E. Berger and E. Liang, Inverted autonomous helicopter ight via reinforcement learning, International Symposium on Experimental Robotics, 2004 - K. Harbick, J. F. Montgomery, G. S. Sukhatme, Planar Spline Trajectory Following for an Autonomous Helicopter, Journal of Advanced Computational Intelligence - Computational Intelligence in Robotics and Automation, Vol. 8, No. 3, pp. 237-242, May 2004.

SVCP- Electronics & Telecommunication Engineering 61

You might also like