Hitachi Freedom Storage Hitachi Dynamic Link Manager (HDLM) Users Guide for Sun Solaris Systems

2002 Hitachi Data Systems Corporation, ALL RIGHTS RESERVED


Notice: No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, or stored in a database or retrieval system for any purpose without the express written permission of Hitachi Data Systems Corporation. Hitachi Data Systems reserves the right to make changes to this document at any time without notice and assumes no responsibility for its use. Hitachi Data Systems products and services can only be ordered under the terms and conditions of Hitachi Data Systems applicable agreements. All of the features described in this document may not be currently available. Refer to the most recent product announcement or contact your local Hitachi Data Systems sales office for information on feature and product availability. This document contains the most current information available at the time of publication. When new and/or revised information becomes available, this entire document will be updated and distributed to all registered users.

Trademarks
Hitachi Data Systems is a registered trademark and service mark of Hitachi, Ltd., and the Hitachi Data Systems design mark is a trademark and service mark of Hitachi, Ltd. Hitachi Freedom Storage and Thunder 9200 and Lightning 9900 are trademarks of Hitachi Data Systems Corporation. Tru64 UNIX is a registered trademark of Compaq Corporation in the US. Sun Microsystems and Solaris are trademarks or registered trademarks of Sun Microsystems, Inc. in the United States and other countries. SPARC and SPARCstation are trademarks or registered trademarks of SPARC International, Inc. and are licensed exclusively to Sun Microsystems, Inc. UNIX is a registered trademark of X/Open Company Limited in the United States and other countries and is licensed exclusively through X/Open Company Limited. Veritas and Veritas Cluster Server are trademarks or registered trademark of Veritas Software Corporation. All other brand or product names are or may be trademarks or service marks of and are used to identify products or services of their respective owners.

HDLM Users Guide for Sun Solaris Systems

iii

Notice of Export Controls


Export of technical data contained in this document may require an export license from the United States government and/or the government of Japan. Please contact the Hitachi Data Systems Legal Department for any export compliance questions.

Document Revision Level


Revision MK-92DLM114-P MK-92DLM114-P1 MK-92DLM114-0 Date February 2002 March 2002 April 2002 Description Preliminary release Revision 1 of preliminary release. This revision supersedes and replaces MK-92DLM114-P. Initial release. This revision supersedes and replaces MK-92DLM114-P1.

Source Document Revision Level


For a description of the changes in this document, please refer to the revision history of the Hitachi source document, Administrators Guide, Hitachi Dynamic Link Manager, Manual number: 3020-3-C23(E).

Changes in the Revision


Replaced and updated Figure 1.1, Figure 2.7, Figure 3.1, and Figure 3.3 Added references to 9900 V Series to section 2.6.1. Corrected event log to OS log (sections 2.7, 2.7.1, 2.7.2, and 3.4) Replaced Figure 4.18 and corrected the text referring to it. Removed /core-file-directory from Table 5.1. Added more Error Codes (Table B.3) Made various typographical error corrections (throughout)

iv

Preface

Preface
The Hitachi Freedom Storage Hitachi Dynamic Link Manager (HDLM) Users Guide describes and provides instructions for installing and using the HDLM feature of the Hitachi Freedom Storage Series disk array subsystems. This manual is intended for system administrators who use Hitachi Dynamic Link Manager (hereafter referred to as HDLM) to operate and manage storage. The readers of this manual must have a basic knowledge of Solaris systems. This users guide assumes that: the user has a background in data processing and understands direct-access storage device (DASD) subsystems and their basic functions, the user is familiar with the Hitachi Lightning 9900 and Thunder 9200 array subsystems, and, the user is familiar with the Sun Solaris file system, system commands, and utilities. For further information on the 9900 subsystem, please refer to the Hitachi Lightning 9900 User and Reference Guide (MK-90RD008). For further information on Hitachi Data Systems products and services, please contact your Hitachi Data Systems account team, or visit Hitachi Data Systems online at http://www.hds.com.

COMMENTS
Please send us your comments on this document: doc.comments@hds.com. Make sure to include the document title, number, and revision. Please refer to specific page(s) and paragraph(s) whenever possible.
(All comments become the property of Hitachi Data Systems Corporation.)

Thank you!

HDLM Users Guide for Sun Solaris Systems

vi

Preface

Contents
Chapter 1 Overview of Hitachi Dynamic Link Manager (HDLM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.1 1.2 Hitachi Dynamic Link Manager (HDLM). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 HDLM Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Chapter 2

HDLM Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.1 2.2 2.3 2.4 2.5 2.6 Configuration Basics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 HDLM System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 LU Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Host Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Load Distribution Using Load Balancing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Failover Using Path Switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2.6.1 Automatic Path Switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2.6.2 Manual Path Switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 2.6.3 Path Status Transition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Error Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 2.7.1 Logs Collected . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 2.7.2 Error Information Filtering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Cluster Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

2.7

2.8

Chapter 3

HDLM Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3.1 Overview of Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1.1 Flow of Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1.2 Program Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Constructing the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2.1 Installation and Uninstallation from CD-ROM. . . . . . . . . . . . . . . . . . . . . . . . 3.2.1.1 Installing HDLM on a Solaris System . . . . . . . . . . . . . . . . . . . . . . 3.2.1.2 Automatic Mount Setup Procedure . . . . . . . . . . . . . . . . . . . . . . . . 3.2.1.3 Uninstalling HDLM on a Solaris System . . . . . . . . . . . . . . . . . . . . 3.2.2 Starting the HDLM Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2.3 Stopping the HDLM Manager. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2.4 Checking Path Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Using the Error Management Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.3.1 Error Information Checking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.3.1.1 Information Displayed by the View Command . . . . . . . . . . . . . . . 3.3.1.2 Error Messages Displayed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.3.2 Path Health Checking. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.4.1 Actions Taken for a Path Error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.4.2 Actions Taken for a Program Error. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 17 18 19 19 19 22 23 24 24 25 26 26 27 29 30 31 31 33

3.2

3.3

3.4

HDLM Users Guide for Sun Solaris Systems

vii

Chapter 4

Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
4.1 Overview of the Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1.1 Command Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1.2 Operations of the HDLM Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1.3 Clear Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1.4 Help Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1.5 Offline Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1.6 Online Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1.7 Set Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1.8 View Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 35 36 37 38 39 40 41 44

Chapter 5

The HDLM DLMgetras Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49


5.1 5.2 Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HDLM Details. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2.1 DLMgetras Format. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2.2 DLMgetras Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2.3 Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2.4 Important Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 49 49 49 50 51

Appendix A Messages and Alerts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 Acronyms and Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 Index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

viii

Contents

List of Figures
Figure 1.1 Figure 2.1 Figure 2.2 Figure 2.3 Figure 2.4 Figure 2.5 Figure 2.6 Figure 2.7 Figure 2.8 Figure 3.1 Figure 3.2 Figure 3.3 Figure 3.4 Figure 3.5 Figure 3.6 Figure 3.7 Figure 3.8 Figure 3.9 Figure 3.10 Figure 3.11 Figure 3.12 Figure 3.13 Figure 3.14 Figure 3.15 Figure 3.16 Figure 3.17 Figure 3.18 Figure 3.19 Figure 3.20 Figure 4.1 Figure 4.2 Figure 4.3 Figure 4.4 Figure 4.5 Figure 4.6 Figure 4.7 Figure 4.8 Figure 4.9 Figure 4.10 Figure 4.11 Figure 4.12 Figure 4.13 Figure 4.14 Figure 4.15 Figure 4.16 Connection Between Hosts and Storage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 HDLM System Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 LU Configuration Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 LU Configuration and HDLM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Load Balancing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Path Switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Path Status Transition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Error Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Path Switching with Clustering Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 HDLM Operational Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HDLM Program Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Editing the /kernel/drv/dlmfdrv.conf file. . . . . . . . . . . . . . . . . . . . . . . . . . . . Specifying Variables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Restarting the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Command Execution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Output File Settings Image. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Example of editing the /etc/vfstab file. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Stopping the HDLM Manager. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Releasing the HDLM Manager Mount Points . . . . . . . . . . . . . . . . . . . . . . . . . . . Restarting the Solaris System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Starting the HDLM Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Stopping the HDLM Manager. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Logging Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View Command -path Information Display. . . . . . . . . . . . . . . . . . . . . . . . . . . . Example KAPL08022-E Error Message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Troubleshooting Procedure for a Path Error . . . . . . . . . . . . . . . . . . . . . . . . . . Path Information Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Troubleshooting Procedure for a Program Error . . . . . . . . . . . . . . . . . . . . . . . Program Error Action Command. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Command Format. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Clear Command Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Clear Statistics After User Command Execution Confirmation Request. . . . . . Clear Statistics with No User Command Execution Confirmation Request. . . . Help Command Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Display All HDLM Operations Available (Default) . . . . . . . . . . . . . . . . . . . . . . . Display the online Operation Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Example of help Command Displaying Operation Format. . . . . . . . . . . . . . . . Path autoPATH_ID 000001 offline, No User Confirmation Request . . . . . . . . . Path autoPATH_ID 000002 online, No User Confirmation Request. . . . . . . . . . Setting the Log Level with User Command Execution Confirmation . . . . . . . . View Command Displaying Program Information . . . . . . . . . . . . . . . . . . . . . . . View Command Displaying Path Information . . . . . . . . . . . . . . . . . . . . . . . . . . Displaying HDLM Function Setting Information . . . . . . . . . . . . . . . . . . . . . . . . Displaying HDLM Manager Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Displaying HDLM Alert Driver Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . HDLM Users Guide for Sun Solaris Systems 17 18 20 21 21 21 22 22 23 23 23 24 24 26 27 29 31 32 33 33 35 37 37 37 38 38 38 38 39 40 43 44 44 45 46 46 ix

Figure 4.17 Displaying HDLM Driver Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Figure 4.18 Displaying Host Device Path Information (host device name = /mntpt). . . . . . 47 Table 4.10 Host Device Path Information Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Figure 5.1 Figure 5.2 DLMgetras Format. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Defining Information to be Collected . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50

List of Tables
Table 2.1 Table 2.2 Table 2.3 Table 2.4 Table 3.1 Table 3.2 Table 3.3 Table 4.1 Table 4.2 Table 4.3 Table 4.4 Table 4.5 Table 4.6 Table 4.7 Table 4.8 Table 4.9 Table 5.1 Table A.1 Table A.2 Table A.3 HDLM System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Components and Descriptions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Log Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Error Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Functions of HDLM Programs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Logging Level Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Physical Path Representation in Solaris Systems . . . . . . . . . . . . . . . . . . . . . . 27 HDLM Command Operations and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . Logging Level Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Trace Levels Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Default Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View Command Parameters and Displayed Information . . . . . . . . . . . . . . . . . . HDLM Function Settings Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HDLM Manager Information Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HDLM Alert Driver Information Description . . . . . . . . . . . . . . . . . . . . . . . . . . . HDLM Driver Information Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 41 42 43 44 45 46 46 47

List of Error Information to be Collected by DLMgetras Utility . . . . . . . . . . . . 51 Message Format and Descriptions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Message Terminology and Definitions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Messages and Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

Contents

Chapter 1
1.1

Overview of Hitachi Dynamic Link Manager (HDLM)

Hitachi Dynamic Link Manager (HDLM)


The Hitachi Dynamic Link Manager (HDLM) program enables high-speed processing of large volumes of data on a network. Networks dedicated to data transfer, such as a storage area network (SAN), can use this technology to provide access to storage. HDLM is a program that manages access paths to storage. It provides functions for distributing the load across paths and switching to another path if there is a failure in a path in use, thus improving reliability of the system. Figure 1.1 illustrates the connection between hosts and storage.

Figure 1.1

Connection Between Hosts and Storage

HDLM supports the following storage subsystems: Hitachi Freedom Storage 5700E Hitachi Freedom Storage 5800 Hitachi Freedom Storage 7700E Hitachi Freedom Storage Thunder 9200 Hitachi Freedom Storage Lightning 9900 Hitachi Freedom Storage Lightning 9900 V Series

HDLM Users Guide for Sun Solaris Systems

1.2

HDLM Features
Load balancing: When multiple paths connect a host and storage, HDLM distributes the load across multiple paths. This prevents a heavily loaded path from affecting processing speed. For details about load balancing, see section 2.5. Failover: When multiple paths connect a host and storage, HDLM switches to another path if there is a failure in the current path being used. This allows processing to continue without interruption due to failure of a data access path. For details about failover, see section 2.6.

Chapter 1 Overview of HDLM

Chapter 2
2.1

HDLM Configuration

Configuration Basics
In a large-scale storage system, fibre cables or SCSI cables connect a host and storage. The cable port on the host is a host bus adapter (HBA). The cable port on storage is a port (P) on a disk controller (DKC). A logical unit (LU) contained in storage is the target of input/output to and from the host. The LU can also be divided into devices (Dev). The connection path between the host and device is simply called a path. In the description of the operation of, and procedures for, HDLM, the connection path between the host and LU is called a physical path. HDLM manages the paths. A path may also be called a management target. Figure 2.1 shows the HDLM system configuration.

Figure 2.1

HDLM System Configuration

HDLM Users Guide for Sun Solaris Systems

2.2

HDLM System Components


The following table contains the HDLM system components (Table 2.1).

Table 2.1
Components Dev DKC HBA LU P Path Physical path

HDLM System Components


Description A logical division of a logical unit (LU). For Solaris systems, a device is called a slice. Disk controller Host bus adapter. This serves as a cable port on the host. Logical unit in storage. An LU is the target of input/output to and from the host. A port on a disk controller. This serves as a cable port on storage. A connection path between the host and device. A connection path between the host and LU.

2.3

LU Configuration
The host operating system recognizes an LU for each physical path. A host LU (HLU) is an LU that the operating system recognizes. Each host LU has the same device as the storage LU has. This is called a host device (HDev). Even if multiple host devices actually point to the same device in storage, the user sees independent host devices. Figure 2.2 shows the LU configuration and how an administrative tool displays the disk configuration.

Figure 2.2

LU Configuration Display

Chapter 2

HDLM Configuration

2.4

Host Components
The following table contains HDLM component abbreviations and descriptions (Table 2.2). Table 2.2
Components HDev HLU

Components and Descriptions


Description Host device, a device within a host LU. The HDev entity is a device in storage. Host LU, an LU that the host recognizes. The HLU entity is an LU in storage.

HDLM consolidates identical LUs that are duplicates, as shown in Figure 2.2. This allows administrative tools such as Disk Administrator to display the actual LU storage configuration. Figure 2.3 is an example of LU storage configuration and how an administrative tool displays disk configuration when using HDLM.

Figure 2.3

LU Configuration and HDLM

HDLM Users Guide for Sun Solaris Systems

2.5

Load Distribution Using Load Balancing


When a system contains more than one path for a single device within an LU, HDLM can distribute the load across the paths by using the paths to issue I/O commands. This function is called load balancing. Load balancing prevents a heavily loaded path from affecting performance of the entire system. When using the Hitachi Freedom Storage 5700E, Hitachi Freedom Storage 5800, or Hitachi Freedom Storage Thunder 9200, HDLM performs load balancing between two or more owner paths or between two or more non-owner paths. An owner path is a path that uses the disk controller (owner disk controller) to provide the fastest access to the LU. A nonowner path is a path that uses a disk controller other than the owner disk controller (nonowner disk controller). Since the owner disk controller varies depending on the LU, the owner path also varies depending on the LU. To prevent performance deterioration for the entire system, HDLM does not perform load balancing between an owner path and a nonowner path. For example, when the Hitachi Freedom Storage 5700E, Hitachi Freedom Storage 5800, or Hitachi Freedom Storage Thunder 9200 is in use, the owner disk controller for LU0 is DKC0. When a device within LU0 is accessed, HDLM performs load balancing between the paths that access the device via physical paths (1) and (2) (that is, between owner paths), or between the paths that access the device via physical paths (3) and (4) (that is, between non-owner paths). When the Hitachi Lightning 9900, 7700E and 9900V subsystems are in use, all the paths are owner paths, therefore HDLM performs load balancing among all the paths accessing the same device. For example, when the Hitachi Lightning 9900, 7700E and 9900V subsystems are in use, all the paths are the owner paths; therefore, when a device within LU0 is accessed, HDLM performs load balancing among all the paths that access the device via physical paths (1), (2), (3), and (4). Figure 2.4 illustrates this.

Chapter 2

HDLM Configuration

Figure 2.4

Load Balancing

You can specify whether to use load balancing by executing the set operation. For details about the set operation, see section 4.1.7.

HDLM Users Guide for Sun Solaris Systems

2.6

Failover Using Path Switching


When the system contains more than one path for a single device within an LU and an error occurs in the path being used, HDLM can switch to another normal path to allow the system to continue to operate. This function is called failover. Two types of failover are available: Automatic path switching Manual path switching Note: When using the Hitachi Freedom Storage 5700E, the Hitachi Freedom Storage 5800, and the Hitachi Freedom Storage Thunder 9200, be sure to set the data share mode.

2.6.1

Automatic Path Switching


If an error occurs in a path, the Failover function automatically places the error path offline to allow the system to continue to operate using another online path. Automatic path switching is applicable to errors of the following levels that occurred in a management target: Critical: A fatal error that may stop the system. Error: A high-risk error that can be avoided by using failover or other countermeasures. For more information about error levels, see section 2.7.2. When using the Hitachi Freedom Storage 5700E, Hitachi Freedom Storage 5800, or Hitachi Freedom Storage Thunder 9200, HDLM selects the switching destination from the paths that access the same device, in the order of owner paths and non-owner paths. For example, in Figure 2.5, the owner disk controller for LU0 is DKC0, and access to a device within LU0 is made only by the path via physical path (1). After the path being used is placed offline, as the first candidate for the switching destination, HDLM selects the path that accesses the same device via physical path (2). As the second candidate, HDLM selects the path that accesses the same device via physical path (3) or (4). When the Hitachi Lightning 9900, 7700E and 9900V subsystems are in use, all the paths are owner paths, meaning that all the paths accessing the same device can be used as switching destinations. For example, if a device within LU0 is accessed using only the path that is via physical path (1) and the path being used is placed offline, as the switching destination HDLM selects one of the paths that access the same device via physical path (2), (3), or (4) (Figure 2.5). All paths that use the same physical path are switched at once. Therefore, if an error occurs in a path, HDLM switches all the other paths that are affected via the same physical path.

Chapter 2

HDLM Configuration

Figure 2.5

Path Switching

After recovery from the error, the offline path does not become active automatically. Executing the online operation of the HDLM command places the path online that was placed offline due to the error. When using the Hitachi Freedom Storage 5700E, Hitachi Freedom Storage 5800, or Hitachi Freedom Storage Thunder 9200, HDLM selects the path to use from online owner paths, and then from online non-owner paths. Therefore, if the online operation places an owner path online while any non-owner path is in use, the path to use is switched to the owner path. When the Hitachi Freedom Storage Lightning 9900, 7700E, or 9900V subsystems are in use, all the paths are owner paths. Therefore, if the online operation places any path online, the path to use is not switched. For details about the online operation, see the description about online in Chapter 4.

HDLM Users Guide for Sun Solaris Systems

2.6.2

Manual Path Switching


To manually switch a path, you can execute the offline operation of the HDLM command to place the path offline. Manually and temporarily switching a path is useful for maintenance of the system. HDLM selects the switching destination path the same way as for automatic path switching. When using the Freedom Storage 5700E, Freedom Storage 5800, or Thunder 9200, HDLM selects the switching destination path from owner paths and then from non-owner paths. When the Hitachi Lightning 9900, 7700E, and 9900V subsystems are in use, all the paths accessing the same device can be the possible switching destination at the same time. All paths that use the same physical path are switched at once. Therefore, if a path is placed offline, HDLM switches all the other paths that are via the same physical path. Executing the online operation places the offline path online. HDLM selects the path to use after executing the online operation in the same way as for automatic path switching. When using the Hitachi Freedom Storage 5700E, Hitachi Freedom Storage 5800, or Hitachi Freedom Storage Thunder 9200, HDLM selects the path to use from online owner paths, and then from online non-owner paths. When the Hitachi Lightning 9900, 7700E and 9900V subsystems are in use, the path to use is not switched after execution of the online operation. For details about the offline and online operations, see the descriptions about offline and online in Chapter 4.

10

Chapter 2

HDLM Configuration

2.6.3

Path Status Transition


There are two types of path status: online and offline. Online means the status in which I/O can normally be issued to the path. Offline means the status in which I/O cannot be issued to the path because the user executed the offline operation of the HDLM command. Figure 2.6 shows the status transition of a path.

Figure 2.6

Path Status Transition

The last online path for each device is not placed offline even if an error occurs or even if the user executes the offline operation. This ensures access to the LU. If an error occurs in the last online path for each device, HDLM checks the status of other paths that are already placed offline. If any path can be placed online, HDLM places that path online and switches to it.

HDLM Users Guide for Sun Solaris Systems

11

2.7

Error Management
HDLM has an error management function that filters error information according to the error level and collects it in logs. Figure 2.7 shows an overview of error management.

Figure 2.7

Error Management

12

Chapter 2

HDLM Configuration

2.7.1

Logs Collected
HDLM collects error logs and OS logs. The log files are in ASCII format and describe and explain the status of the error, and present an analysis of the cause of the error for troubleshooting purposes. HDLM Error log files are stored in the directory /opt/DynamicLinkManager/log/. Table 2.3 describes the logs.

Table 2.3
Log name Error log OS log

Log Descriptions
Description Error information for the user-defined level is collected from detected errors. By default, HDLM collects all detected error information. Information about highly dangerous errors (Critical or Error level) is collected from detected errors. OS logs that are collected by UNIX-based systems are called syslogs. Syslogs can be checked using a text editor (see Note 1).

Note 1: Syslog file paths are specified in the /etc/syslog.conf file. The syslog default file path collected by Solaris is /var/adm/messages. For details about error levels, see section 2.7.2.

HDLM Users Guide for Sun Solaris Systems

13

2.7.2

Error Information Filtering


Errors that HDLM detects are classified into error levels. Table 2.4 shows the error levels.

Table 2.4
Error level Critical Error Warning Information

Error Descriptions
Meaning Fatal error that may stop the system High-risk error that can be avoided by using failover or other countermeasures Although the system continues to operate, it is risky to let the error remain. Indicates the operation history when the system operates normally. OS Log Error Error

The Log Filter organizes error information according to error level. It filters error information to be collected for an error log or an OS log. The Log Filter does not collect an error log. The error log collects error information for all logging levels, including Error and higher, Warning, and Information levels. The errors logged are categorized in the following order: Does not collect an error log Error or higher level. Warning or higher level. Information or higher level (that is, all levels). For details about how to set the logging level, see section 3.3.

14

Chapter 2

HDLM Configuration

2.8

Cluster Support
HDLM supports Veritas Cluster Server software. HDLM automatically recognizes the cluster configuration at startup and performs the appropriate processing. When load balancing is supported in a cluster configuration, HDLM uses more than one physical path on the active host for one LU, and accesses devices within the LU by using the paths via the physical path. When load balancing is not supported in a cluster configuration, HDLM uses only one of the physical paths of the active host for one LU, and accesses devices within the LU by using the paths that are via the physical path. All paths that use the same physical path are switched at once; therefore, if an error occurs in a path, HDLM switches all the other paths that are via the same physical path to other paths using another physical path of the active host. When the active host no longer has any physical path that contains only online paths, the cluster software switches to the standby host. For example, to access a device within the LU, HDLM uses a path that is via physical path (1) of the active host (Figure 2.8). If a path is placed offline, to continue processing HDLM switches all the other paths that are via physical path (1). HDLM switches them to the paths that are via physical path (3) of the active host. If a path that is via physical path (3) is also placed offline and the active host no longer has any physical path that contains only online paths, the cluster software switches to the standby host. Then, HDLM in the standby host uses physical path (2) or (4), and accesses the devices within the LU by using paths that are via the selected physical path. For details about node switching triggers, refer to the Veritas Cluster Server product documentation.

Figure 2.8

Path Switching with Clustering Support

Note: To use the HDLM functions in a cluster configuration, HDLM must be installed in both the active host and standby host. HDLM Users Guide for Sun Solaris Systems 15

16

Chapter 2

HDLM Configuration

Chapter 3

HDLM Operations

This chapter describes the procedure required for HDLM operation, including installing HDLM, setting the error management function, and performing troubleshooting. This chapter contains the following sections: 3.1 Overview of operations 3.2 Constructing the system 3.3 Using the error management function 3.4 Troubleshooting

3.1

Overview of Operations

3.1.1

Flow of Operations
Figure 3.1 shows the flow of HDLM operations.

Figure 3.1

HDLM Operational Flow

Note 1: See hardware notes supplied with the product.

HDLM Users Guide for Sun Solaris Systems

17

3.1.2

Program Configuration
HDLM is a combination of programs. To use HDLM, these programs must be running normally. Figure 3.2 shows the HDLM program configuration.

Figure 3.2

HDLM Program Configuration

Table 3.1 shows the function of each program. Table 3.1


Program Name HDLM command HDLM manager HDLM alert driver HDLM driver

Functions of HDLM Programs


Function Manages the paths and displays error information. Collects error logs. Reports the error information detected by the HDLM driver to the HDLM manager. Controls the functions, manages the paths, and detects errors. The HDLM driver contains the core logic component that controls the HDLM basic functions, and the filter component that sends and receives I/O.

18

Chapter 3 HDLM Operations

3.2

Constructing the System


This section describes the required procedures for constructing an HDLM system.

3.2.1

Installation and Uninstallation from CD-ROM


The Hitachi Network Objectplaza Trace Library is installed together with HDLM. This subsection describes the installation method and the uninstallation method for the Sun Solaris operating system. For details on updating HDLM, uninstalling the software, and then re-installing it, see section 3.2.1.

3.2.1.1

Installing HDLM on a Solaris System


To install HDLM: 1. Log on as a user with root permission. 2. Insert the CD-ROM into the drive. After a few seconds, the CD-ROM will be automatically mounted; the CD-ROM mount point will be displayed in the file list.

3. If the CD-ROM is not automatically mounted, execute the following command: # mount /mount-point-of-CD-ROM

4. Execute the following installation command: # pkgadd -d /mount-point-of-CD-ROM DLManager

5. Follow the messages on the screen. 6. When the installation is completed, execute the following command to ensure that the package is installed: # pkginfo -l DLManager

HDLM Users Guide for Sun Solaris Systems

19

7. Edit the /kernel/drv/dlmfdrv.conf file to specify the name of the physical device file for the slice you want to use for path switching. Figure 3.3 shows the system configuration and an example of editing "dlmfdrv.conf".

Figure 3.3

Editing the /kernel/drv/dlmfdrv.conf file

20

Chapter 3 HDLM Operations

Variables: name: Specify the name of device driver. Specify dlmfdrv (DLM driver). parent: Specify the node to link. Specify pseudo to specify the HDLM driver. Instance: Specify the instance number of the driver. The numbers must be sequentially specified from 0 and must be unique. FilterPath: Specify the name of the path that is managed by one instance of the HDLM driver. Specify the device node name for the sd driver under the /devices directory. sd@4,2:c stands for the target ID, LUN, and the slice of the sd driver: 4 (hexadecimal) stands for the target ID 2 stands for LUN c stands for the slice Specify slice 0 to slice 7 using a to h in lower case The slice c stands for the entire LU. Specify from slice c.

Note: To see available devices on the system, execute the command shown in Figure 3.4

# cd /dev/dsk # ls -l

Figure 3.4

Specifying Variables

8. After the kernel/drv/dlmfdrv.conf file has been modified, the system must be rebooted. Execute the command shown in Figure 3.5to restart the system:

# reboot -- -r

Figure 3.5

Restarting the System

9. Mount the logical block device file: /dev/dsk/dlmfdrvn (n stands for the instance number of the driver) of the configured HDLM. An example of command execution is shown in Figure 3.6.

# mkdir /mntpt # mount -F ufs /dev/dsk/dlmfdrv4 /mntpt

Figure 3.6

Command Execution

HDLM Users Guide for Sun Solaris Systems

21

3.2.1.2

Automatic Mount Setup Procedure


To automatically mount HDLM-devices at the Solaris system startup, follow these steps: 1. Execute the following command (Figure 3.7) to output the /etc/vfstab file settings image:

# mount -p

Figure 3.7

Output File Settings Image

2. Use a text editor to edit the /etc/vfstab file while referencing the settings image. For more information, execute the man vfstab command and read the information displayed.

Figure 3.8

Example of editing the /etc/vfstab file

3. Add the shaded code show in Figure 3.8. The line above the shaded line is set during the Solaris system installation and setup. The contents of the lines above the shaded line differ depending on the environment. 4. In the mount point column, specify the mount point. In the mount at boot column, specify yes.

22

Chapter 3 HDLM Operations

3.2.1.3

Uninstalling HDLM on a Solaris System


To uninstall HDLM: 1. Log on to Solaris as a user with root permission. 2. Terminate all programs that issue I/Os by using HDLM. 3. Execute the following command (Figure 3.9) to stop the HDLM manager:

# /etc/init.d/DLMManager stop

Figure 3.9

Stopping the HDLM Manager

4. Execute the following command (Figure 3.10) to release the mount points that use the HDLM Manager:

# umount /mount-point

Figure 3.10 Releasing the HDLM Manager Mount Points 5. Execute the following uninstallation command:

# pkgrm DLManager

6. When the message confirming the uninstallation is displayed, enter y. Uninstallation will begin. 7. When you complete uninstallation, execute the following command (Figure 3.11) to restart the system:

# reboot -- -r

Figure 3.11 Restarting the Solaris System

HDLM Users Guide for Sun Solaris Systems

23

3.2.2

Starting the HDLM Manager


For UNIX-based systems, the HDLM manager uses the start script that is set up during installation. Therefore, starting a UNIX-based operating system automatically starts the HDLM manager. If the HDLM manager has stopped, start it using the following steps: 1. Initiate the start script that was set up during installation. 2. Log on to the Solaris system as a user with root permission, and then execute the following command (Figure 3.12):

# /etc/init.d/DLMManager start

Figure 3.12 Starting the HDLM Manager

3.2.3

Stopping the HDLM Manager


HDLM stops automatically when uninstalling, or when installing a new instance of HDLM on a system in which HDLM is already installed. If HDLM does not stop automatically, stop it using the following steps: 1. Initiate the stop script that was set up during installation. 2. Log on to the Solaris system as a user with root permission, and then execute the following command (Figure 3.13):

# /etc/init.d/DLMManager stop

Figure 3.13 Stopping the HDLM Manager

24

Chapter 3 HDLM Operations

3.2.4

Checking Path Information


You can use the HDLM functions such as load balancing and failover when there is more than one online path for a single device. After installing HDLM and after changing the hardware configuration, you need to check the path information, including the configuration of paths and their status. Note: After changing the hardware configuration of the system be sure to restart the machine. This allows HDLM to recognize the changes in the hardware configuration. Note: Be sure to start the storage subsystem before starting the host machine. This allows the operating system to detect the storage subsystem. To check the path information: 1. Execute the view operation of the HDLM command to display the path information. Enter as follows: >dlnkmgr view -path > pathinfo.txt pathinfo.txt indicates the redirect destination file name. Set the file name according to your environment. Executing this command displays information about all paths.

2. Open the redirected file (pathinfo.txt in step 1) and check the following: LUs that physical paths access A PathName identifies the physical path. A combination of DskName and iLU identifies the LU that a physical path accesses. If the physical paths access the same LU via different host bus adapters, check that: The first number in PathName (port number of the host bus adapter) differs among the physical paths accessing the same LU There are as many port numbers for the separate host bus adapters as there are physical host bus adapters. If the physical paths access the same LU via different disk controllers, check that: Multiple disk controllers are physically mounted The DkcPort indication (port number of the disk controller) differs among the physical paths accessing the same LU, and indicates the port number of different disk controller. Path status: Check whether the state conditions are all Online. For details about the items that the view operation displays, see section 4.1.8.

HDLM Users Guide for Sun Solaris Systems

25

3.3

Using the Error Management Function


HDLM has the error management functions for logging and displaying error information, and path health checking. This section describes how to set the logging level and how to check information if an error occurs. The example in Figure 3.14 sets 2 for the value of the logging level. Table 3.2 shows the values of the logging level.
>dlnkmgr set -ellv 2

Figure 3.14 Logging Level Table 3.2


Value 0 1 2 3

Logging Level Values


Description Do not collect an error log. Collect error information for the Error or higher level. Collect error information for the Warning or higher level. Collect error information for the Information or higher level (that is, all levels).

The default is 3. To check the set value for the logging level, use the HDLM view command to display the HDLM function settings.

3.3.1

Error Information Checking


You can check for an error by referring to: Information displayed by the HDLM view command The message that is output when an error occurs.

26

Chapter 3 HDLM Operations

3.3.1.1

Information Displayed by the View Command


You can use the view command to check error information. For example, specify path in the view command parameters to display the path information. Figure 3.15 shows an example of displayed information. Note: Equipment that is not mounted is also displayed when the -hdev parameter is not used.

>dlnkmgr view path hdev /mntpt Paths:00002 OnlinePaths:00002 PathState IO-Counts IO-Errors Online 1332 0 PathID PathName DskName iLU DkcPort State Type IO-Counts IO-Errors DNum HDevName 000011 004.0004.00029.0002 HITACHI.DF400F .1234 0010 1B Online own 1332 0 1 /mntpt ... KAPL01001-I The HDLM > command completed successfully. Operation name = view

Figure 3.15 View Command -path Information Display Check the following items in the display for path errors: PathID: The ID that HDLM assigned to the path at system startup. This ID is called AutoPATH_ID. PathName: The path name that identifies a physical path. A path name consists of four items separated by a period. Table 3.3 shows these items and their representation in Solaris systems. Table 3.3
Items Port number of the host bus adapter (Display example: 004) Bus number (Display example: 0004) Target ID (Display example: 00029) Host LU number (Display example: 0002)

Physical Path Representation in Solaris Systems


Representation in Solaris systems (see Note) HBA Port number 0 (fixed) Target Id Logical Unit ID or LUN

HDLM Users Guide for Sun Solaris Systems

27

Note: The following is additional information about path name items in Solaris systems: Port number of Host Bus Adapter: See the instance number of the corresponding Host Bus Adapter defined in the /etc/path_to_inst file. Bus number: Is fixed to 0 Target ID See the target clause in the /kernel/drv/sd.conf file. Host LU number: See the LUN clause in the /kernel/drv/sd.conf file. DskName: The storage subsystem name identifying the storage subsystem. A storage subsystem name consists of three items separated by a period: Vendor ID (Display example: HITACHI): Vendor name of the storage subsystem Product ID (Display example: DF400F): Model name of the storage subsystem Serial number (Display example: 1234): Serial number of the storage subsystem.

Note: To physically identify the storage subsystem, use the management program for the storage subsystem to refer to these information items. iLU The number assigned to an LU managed in the storage subsystem. You can use this number to identify the LU in the storage subsystem. For the Hitachi Lightning 9900, 7700E and 9900V subsystems, the first two letters of the iLU indicates the CU (Control Unit) number, and the last two letters indicates the internal LU number in the CU. For the Hitachi Freedom Storage 5700E, Hitachi Freedom Storage 5800, and Hitachi Freedom Storage Thunder 9200, the entire iLU indicates the internal LU number in the storage subsystem. To physically identify the LU, use the management program for the storage subsystem to refer to iLU.

DkcPort Port number of the disk controller. You can use this number to identify the disk controller mounted on the storage subsystem. To physically identify the disk controller, use the management program for the storage subsystem to reference this port number.

28

Chapter 3 HDLM Operations

State: Status of the path Online: path is online Offline(C): Path is offline by a command Offline(E): Path is offline due to an error.

Note: A path that has the same PathName as a path whose state is Offline may be in an error status even though its state is Online. Dnum: Device number HdevName: Host device name In Solaris systems, the mount point is displayed in this field. When the file system is not mounted, a hyphen (-) is displayed. Device numbers are assigned to each device within an LU. The device numbers are assigned sequentially from 0.

3.3.1.2

Error Messages Displayed


Referring to the output message in the OS log allows you to check the information about the error. For example, the following message is output if a path error occurs (Figure 3.16): KAPL08022-E
A path error occurred. ErrorCode=%d, PathID=%d, PathName=%d.%d.%d.%d, DNum=%d, HDevName=%s

Figure 3.16 Example KAPL08022-E Error Message Note: %d is a decimal number and %s is a character string. Check the following items in the display for path errors: ErrorCode: The error number when the operating system detected the path error.

PathID: The ID that HDLM assigned to the path at system startup. This ID is called AutoPath_ID. Note: this is the same as PathID that the view operation displays.

HDLM Users Guide for Sun Solaris Systems

29

PathName: Identifies the physical path. A path name consists of four items separated by a period. Note: this is the same as PathName that the view operation displays. For details, see the description of PathName in Table 3.3.

Dnum: Device number. Device numbers are assigned to each device within an LU. The device numbers are assigned sequentially from 0. Note: This is the same as DNum that the view operation displays.

HdevName: Host device name. In Solaris systems, the mount point is displayed in this field. When the file system is not mounted, a hyphen (-) is displayed. This is the same as HDevName that the view operation displays.

3.3.2

Path Health Checking


The HDLM program checks the status of the paths at regular intervals through a subprogram called path health checking. When an error occurs in a path in the Online status, path health checking changes the status of the path to the Offline(E) status. When a path that was in the Offline(E) status recovers from an error, path health checking changes the status of the path to the Online status. Path health checking checks paths in the Online status and paths in the Offline(E) status. Path health checking does not check the status of the paths in the Offline(C) status by executing the offline operation. You can specify whether to use path health checking by executing the set operation. For details about the set operation, see the description of set in section 4.1.7.

Note: In previous versions of HDLM, executing a batch file that defined the online operation performed path health checking. With the current version, executing the set operation performs path health checking; do not execute the batch file. If the set operation is executed, the result will be duplicate instances of path health checking running simultaneously.

30

Chapter 3 HDLM Operations

3.4

Troubleshooting
This section describes the actions you should take HDLM detects a path error or when an error occurs in a HDLM program. For details about hardware maintenance, see the appropriate hardware manual accompanying the purchased product.

3.4.1

Actions Taken for a Path Error


When a path error is detected, HDLM performs failover for the path and outputs a KAPL08022 message. Figure 3.17 shows the troubleshooting procedure when this message is output.

Figure 3.17 Troubleshooting Procedure for a Path Error

HDLM Users Guide for Sun Solaris Systems

31

Monitoring the message Read the KAPL08022 message output to the OS log. For details about the contents of the message, see section 3.3.1.2 and Appendix A.

Obtaining the path information Execute the following command to obtain the path information (Figure 3.18):

>dlnkmgr view -path > pathinfo.txt

Figure 3.18 Path Information Command pathinfo.txt indicates the redirect destination file name. Determine the file name according to your environment.

Extracting the error path: Check the obtained path information to find the error path. The path whose state indication is Offline(E) is the error path. (A path that has the same PathName as a path whose state is Offline may be in an error status even though its state is Online.) Next, search for the online error path. For the path for which Online is indicated in the path information, compare its PathName with the PathName in the KAPL08022 message. If both PathNames are the same, this path has the error. (Since HDLM always leaves one online path for each device, an error path actually exists even if the path information only indicates Online.)

Identifying the hardware that may have the error: Check the DskName, iLU, and DkcPort of the error path to narrow down the hardware that may have the error. Use the management program for the storage subsystem to check the DskName, iLU, and DkcPort to physically identify the hardware.

Identifying the error section and taking corrective action: Use the administrative tools for the operating system and hardware to identify the error section, and then take corrective action.

Placing the path online: After recovery from the error, place the paths online that were placed offline due to the error. Execute the following command:

>dlnkmgr online

This command places all the offline paths online.

32

Chapter 3 HDLM Operations

3.4.2

Actions Taken for a Program Error


The following describes the actions you should take when an error occurs in an HDLM program. Figure 3.19 shows the troubleshooting procedure.

Figure 3.19 Troubleshooting Procedure for a Program Error Monitoring the message If an error occurs in the HDLM program, a message whose message ID is other than KAPL08xxx is output to the OS log. Check the output message. Messages with error level E (Error) or higher require corrective action.

Taking the action for the error Take the action according to the information in Appendix A, Messages and Alerts. If the same error occurs again after you take the action, check the status of the HDLM program. Execute the following command (Figure 3.20):

>dlnkmgr view -sys

Figure 3.20 Program Error Action Command

HDLM Users Guide for Sun Solaris Systems

33

If the KAPL01013-E message is displayed, execute the following commands:

>dlnkmgr view -sys -msrv >dlnkmgr view -sys -adrv >dlnkmgr view -sys -pdrv

These commands display information about the HDLM manager, HDLM alert driver, and HDLM driver. Check the indications for HDLM Manager, HDLM Alert Driver, and HDLM Driver, and then take any of the following actions: When HDLM Manager shows Dead, start the HDLM manager service. Note: For details on how to start the HDLM manager, see section 3.2.2. When the HDLM Alert Driver shows Dead, restart the system. When the HDLM Driver shows Dead, restart the system.

Note: If the same error occurs again after you take the above action, contact maintenance personnel. Obtaining program information Obtain the information you need to report to maintenance personnel. For Solaris systems, HDLM provides a utility (DLMgetras) for collecting error information that should be reported to maintenance personnel. For details, see the description of DLMgetras in Chapter 5.

Contacting maintenance personnel Contact maintenance personnel and report the obtained information.

34

Chapter 3 HDLM Operations

Chapter 4

Commands

This chapter describes the HDLM commands set. The following topics are covered: Overview of the commands clear (Clears the management information) help (Displays the operation format) offline (Places a path offline) online (Places one or all offline paths online) set (Sets the operating environment) view (Displays information)

4.1

Overview of the Commands


This section describes how to specify the commands for HDLM, and the operations of the HDLM command itself.

4.1.1

Command Format
Enter a command using the following format:
dlnkmgr operation-name [parameter[parameter-value]]

Figure 4.1

Command Format

Variable definitions are as follows: dlnkmgr Command name

operation-name Type of the operation that is entered after dlnkmgr.

parameter Value required for the operation

parameter-value Value required for the parameter

HDLM Users Guide for Sun Solaris Systems

35

4.1.2

Operations of the HDLM Command


Table 4.1 shows the operations of the HDLM command and their functions. Table 4.1
Operation clear help offline online set view

HDLM Command Operations and Functions


Functions Clears the management information for the Dynamic Link Manager system. Displays the format of the operation used for Dynamic Link Manager. Places an online path offline. Places one or all offline paths online. Sets the Dynamic Link Manager operating environment. Displays Dynamic Link Manager program information and path information.

Notes: 1. When you are using HDLM for Solaris systems, execute the command as a user with root permission. 2. To specify a value containing a space in parameter, enclose the entire value in double quotes (").

36

Chapter 4 Commands

4.1.3

Clear Operation
Function: clears management information from the HDLM system. Format:
dlnkmgr clear -pdst [-s]

Figure 4.2

Clear Command Format

Parameters: -pdst: Clears statistics such as the path error count. -s: Executes the command without displaying user confirmation message. Specify this parameter if you want to skip the user confirmation message for a shell script or batch file.

Examples ( see Figure 4.3, Figure 4.4):


>dlnkmgr clear -pdst dlnkmgr clear -pdst Execute command? [y/n]:y ... Enter y to execute the command. KAPL01001-I The DLM command completed successfully. Operation name = clear >

Figure 4.3

Clear Statistics After User Command Execution Confirmation Request

>dlnkmgr clear -pdst -s KAPL01001-I The DLM command completed successfully. Operation name = clear >

Figure 4.4

Clear Statistics with No User Command Execution Confirmation Request

HDLM Users Guide for Sun Solaris Systems

37

4.1.4

Help Operation
Function: displays the format of an HDLM operation Format:
dlnkmgr help [operation-name]

Figure 4.5

Help Command Format

Parameters: operation-name: specifies the name of an operation used in HDLM.

Note: If you do not specify the operation name, the command displays all the operations (default): Examples (Figure 4.6 and Figure 4.7):

>dlnkmgr help dlnkmgr { clear | help | offline | online | set | view } >

Figure 4.6

Display All HDLM Operations Available (Default)

>>dlnkmgr help online dlnkmgr online [-path] [-pathid AutoPATH_ID] [-s] >

Figure 4.7

Display the online Operation Format

Note: For any operation, entering help following the operation name will display the format of that operation (Figure 4.8).

>dlnkmgr clear -help dlnkmgr clear -pdst [-s] >

Figure 4.8

Example of help Command Displaying Operation Format

38

Chapter 4 Commands

4.1.5

Offline Operation
Function: Places an online path offline. Use the parameter to specify the path you want to place offline. The last path accessing each device cannot be placed offline.

Format:
dlnkmgr offline [-path] -pathid AutoPATH_ID [-s]

Note: Placing too many paths offline may prevent path switching if an error occurs. Before placing the path offline, use the view operation to check how many online paths remain. Parameters: -path: specifies manipulating a path that Dynamic Link Manager manages. Note: Be sure to specify the target path in the subsequent parameter. This parameter is optional because the offline operation is only effective on paths. -pathid AutoPATH_ID: specify the AutoPATH_ID that Dynamic Link Manager assigned to the path during system startup. The command places the specified path offline. Use the view operation to check the AutoPATH_ID. Note: Leading zeros in the AutoPATH_ID can be omitted when it is specified for the parameter value. -s: executes the command without displaying the message asking for confirmation from the user. Specify this parameter if you want to skip the confirmation for a shell script or batch file.

Example (Figure 4.9):


>dlnkmgr offline -pathid 1 -s KAPL01022-I 1 path(s) were processed. Operation name = offline KAPL01001-I The DLM command completed successfully. Operation name = offline >

Figure 4.9

Path autoPATH_ID 000001 offline, No User Confirmation Request

HDLM Users Guide for Sun Solaris Systems

39

4.1.6

Online Operation
Function: Places one or all offline paths online. Use this parameter to specify the path you want to place online.

Format:
dlnkmgr online [-path] [-pathid AutoPATH_ID] [-s]

Parameters: -path: specifies manipulating a path that HDLM manages. Specify the target path in the subsequent parameter. Note: If you do not specify the subsequent parameter, the command changes all the offline paths to online. Note: This parameter is optional because the online operation is only effective on paths. -pathid AutoPATH_ID: specifies the AutoPATH_ID that HDLM assigned to the path during system startup. Places the specified path online. Note: Use the view operation to check the AutoPATH_ID. Leading zeros in the AutoPATH_ID can be omitted when it is specified for the parameter value. -s: executes the command without displaying the message asking for confirmation from the user. Specify this parameter if you want to skip the confirmation for a shell script or batch file.

Example (Figure 4.10):


>dlnkmgr online -pathid 2 -s KAPL01022-I 1 path(s) were processed. Operation name = online KAPL01001-I The DLM command completed successfully. Operation name = online >

Figure 4.10 Path autoPATH_ID 000002 online, No User Confirmation Request

40

Chapter 4 Commands

4.1.7

Set Operation
Function: Sets the HDLM operating environment

Format:
dlnkmgr set {-lb{on|off} |-ellv log-level |-elfs log-size |-systflv trace-level} |-pchk {on [-intvl execution-interval]|off}} [-s]

Parameters: -lb{on|off}: enables or disables the load balancing function. on: Enabled off: Disabled Note: The default is on. -ellv log-level: specify the level of error information you want to collect for an error log. The default value is 3 (see Table 4.2). Logging Level Values
Description Do not collect an error log. Collect error information for the Error or higher level. Collect error information for the Warning or higher level. Collect error information for the Information or higher level (that is, all levels).

Table 4.2
Value 0 1 2 3

-elfs log-size: specify in Kbytes the size of an error log file. Use a value between 100 and 9900. Note: The default is 1000. Note: If the size of the error log file reaches the specified value, HDLM switches to a new file and outputs the data to it. All old files except for the preceding one are deleted.

systflv trace-level: specify the trace output level (see Table 4.3). Note: The default is 0.

HDLM Users Guide for Sun Solaris Systems

41

Table 4.3
Value 0 1 2 3 4

Trace Levels Values


Description Do not output any trace. Only output error information. Output a summary of program operation. Output details of program operation. Output all information.

Note: Larger trace level values cause a greater number of logs to be output. To accommodate a greater number of logs, data wrapping is applied by HDLM to reduce the time required for deleting old logs. Note: Use a trace file applicable to all Hitachi products. Note: The history and results of user-issued commands are output to the trace files regardless of the trace level. -pchk {on [-intvl execution-interval]|off}: Enables or disables path health checking. on: Enabled off: Disabled. The default is off. Note: The path health checking function checks paths that are Online as well as Offline(E) Note: Path health checking does not check the status of paths in the Offline(C) status by executing the offline operation. intvl execution-interval: specifies the path health checking execution interval with a parameter immediately following on. When you omit the execution interval specification, path health checking defaults to every 30 minutes. Specify path health checking intervals in minutes. Use a value between 15 and 1440. The default is 30. Once this parameter is set, it is stored, and the setting takes effect after the OS or the HDLM manager is restarted. Once the OS or the HDLM manager is restarted, path health checking is executed when the specified execution interval has occurred. Note: When you change the execution interval, the new setting takes effect only after path health checking is executed once using the interval specified previously. When you want to change the execution interval immediately, execute the dlnkmgr set -pchk off command to disable path health checking, wait more than five seconds, and then execute the dlnkmgr set -pchk on -intvl execution-interval command. This will change the path health checking execution interval.

42

Chapter 4 Commands

Note: In previous versions of the HDLM software, path health checking was performed by executing a batch file that defined the online operation. Currently, path health checking is performed by executing the set operation; do not execute the batch file or two instances of path health checking will run simultaneously. -s: Executes the command without no user confirmation message display. Specify this parameter if you want to skip the confirmation for a shell script or batch file.

Table 4.4 shows the defaults of the above settings. If you change the value of the set operation, the new value takes effect immediately. Table 4.4
Item Load balancing function Log level Log size Trace level Path health checking function

Default Settings
Default on: Enabled 3: Collect error information for Information or higher level (that is, all levels). 1000 (Kbytes) 0: Do not output any trace. off: Disabled

Example:
>dlnkmgr set -ellv 1 dlnkmgr set -ellv 1 Execute command? [y/n]: y ... Enter y to execute the command. KAPL01001-I The DLM command completed successfully. Operation name = set >

Figure 4.11 Setting the Log Level with User Command Execution Confirmation

HDLM Users Guide for Sun Solaris Systems

43

4.1.8

View Operation
Function: Displays HDLM program information and path information. Format (Figure 4.12 and Figure 4.13):
dlnkmgr view -sys [-sfunc|-msrv|-adrv|-pdrv] [-t ]

Figure 4.12 View Command Displaying Program Information


dlnkmgr view -path [-hdev host-device-name] [-t]

Figure 4.13 View Command Displaying Path Information Parameters: -sys [-sfunc|-msrv|-adrv|-pdrv]: Displays the Dynamic Link Manager program information. In the subsequent parameter, specify the program for which you want to display information. Note: If you do not specify the subsequent parameter, the command displays all program information. Table 4.5 shows the parameters you can specify and the displayed information. Table 4.5
Parameter -sfunc -msrv -adrv -pdrv

View Command Parameters and Displayed Information


Displayed Information Information about the Dynamic Link Manager function settings Information about theHDLM manager Information about theHDLM alert driver Information about theHDLM driver

-path Displays information about the paths that HDLM manages. In the subsequent parameter, specify the path for which you want to display information. You can also specify the host device that the paths access Note: If you do not specify the subsequent parameter, the command displays information for all the paths. Specify the path as follows: -hdev host-device-name Specify the host device name. For Solaris systems, specify the mount point name. The command displays information about all the paths accessing the specified host device.

-t: Does not display the title for each information item.

44

Chapter 4 Commands

Examples (Figure 4.14, Figure 4.15, Figure 4.16, Figure 4.17, and Figure 4.18):
>dlnkmgr view -sys -sfunc Dynamic Link Manager Version Load Balance Support Cluster Elog Level Elog File Size (kbyte) Trace Level Path Health Checking : : : : : : : 03-01 on off 3 1000 1 on(30)

KAPL01001-I The DLM command completed successfully. Operation name = view >

Figure 4.14 Displaying HDLM Function Setting Information Table 4.6 describes the items shown in Figure 4.14. Table 4.6
Item Dynamic Link Manager Version Load Balance

HDLM Function Settings Description


Description HDLM version number consisting of 4 to 6 characters Setting of the load balancing function on: Enabled off: Disabled

Support Cluster

Setting of the cluster support function Setting of the cluster support function (see Note 1) on: Enabled off: Disabled Type of the cluster server Veritas Cluster Server

Elog Level

Logging level 0: Do not collect an error log. 1: Collect error information for the Error or higher level. 2: Collect error information for the Warning or higher level. 3: Collect error information for the Information or higher level (that is, all levels).

Elog File Size (kbyte) Trace Level

Size of the error log file in Kbytes Trace output level 0: Do not output any trace. 1: Only output error information. 2: Output a summary of program operation. 3: Output details of program operation. 4: Output all information.

Path Health Checking

Path health checking function settings: on: Enabled off: Disabled When path health checking is on, the execution interval is displayed in parentheses, in minutes.

HDLM Users Guide for Sun Solaris Systems

45

Note 1: When you use HDLM for Solaris systems in a cluster configuration, off is displayed in the Support Cluster field; however, the cluster support function operates normally.
>dlnkmgr view -sys -msrv DLM Manager Ver WakeupTime Alive 03-01 2001/04/16 11:37:56 KAPL01001-I The DLM command completed successfully. Operation name = view >

Figure 4.15 Displaying HDLM Manager Information Table 4.7 describes the items shown in Figure 4.15. Table 4.7
Item DLM Manager

HDLM Manager Information Description


Description Status of theHDLM manager Alive: Normal Dead: Stopped

Ver WakeupTime

Version number of theHDLM manager Startup time of theHDLM manager

>dlnkmgr view -sys -adrv DLM Alert Driver Ver WakeupTime Elog Mem Size Alive 03-01 2001/04/16 11:28:34 128 KAPL01001-I The DLM command completed successfully. Operation name = view

Figure 4.16 Displaying HDLM Alert Driver Information Table 4.8 describes the items shown in Figure 4.16. Table 4.8
Item DLM Alert Driver

HDLM Alert Driver Information Description


Description Status of theHDLM alert driver Alive: Normal Dead: Stopped

Ver WakeupTime Elog Mem Size

Version number of theHDLM alert driver Startup time of theHDLM alert driver Size of error log memory for theHDLM alert driver

46

Chapter 4 Commands

>dlnkmgr view -sys -pdrv DLM Driver Ver WakeupTime Alive 03-01 2001/04/16 11:28:34 KAPL01001-I The DLM command completed successfully. Operation name = view >

Figure 4.17 Displaying HDLM Driver Information Table 4.9 describes the items shown in Figure 4.17. Table 4.9
Item DLM Driver

HDLM Driver Information Description


Description Status of theHDLM driver Alive: Normal Dead: Stopped

Ver WakeupTime

Version number of theHDLM driver Startup time of theHDLM driver

>dlnkmgr view path -hdev /mntpt Paths:00002 OnlinePaths:00002 PathState IO-Counts IO-Errors Online 1332 0 PathID PathName DskName DkcPort State Type IO-Counts IO-Errors 000011 004.0004.00029.0002 HITACHI.DF400 1B Online Own 1332 0 000005 003.0004.00027.0002 HITACHI.DF400 0B Online Non 0 0 iLU DNum HDevName .1234 0010 1 /mntpt .1234 0010 1 /mntpt

KAPL01001-I The DLM command completed successfully. Operation name = view >

Figure 4.18 Displaying Host Device Path Information (host device name = /mntpt)

HDLM Users Guide for Sun Solaris Systems

47

Table 4.10 describes the information contained in Figure 4.18. Table 4.10
Item Paths OnlinePaths PathState

Host Device Path Information Description


Description Sum of the number of displayed paths, indicated by up to five decimal numbers Number of available paths in the displayed paths, indicated by up to five decimal numbers Status of the displayed paths Online: All paths are available. Shrunken: Some of the paths are available. Offline: No paths are available.

IO-Counts IO-Errors PathID PathName

Total I/O count for the displayed paths, indicated by up to ten decimal numbers Total I/O error count for the displayed paths, indicated by up to ten decimal numbers AutoPATH_ID indicated by up to six decimal numbers Path name indicated by a string of up to 19 one-byte characters. A path name consists of the port number for the host bus adapter, bus number, target ID, and host LU number, each of which is separated by a period. Storage subsystem name indicated by a string of up to 38 one-byte characters. A storage subsystem name consists of the vendor ID, product ID, and serial number, each of which is separated by a period. LU number of the storage subsystem, indicated by a string of up to four one-byte characters Port number of the disk controller, indicated by a string of two one-byte characters. Status of the path Online: Online Offline(C): Offline by a command Offline(E): Offline due to an error

DskName

iLU DkcPort State (see Note 1)

Type

Attribute of the path Own: Owner path Non: Non-owner path

IO-Counts IO-Errors DNum HDevName

Total I/O count for the path, indicated by up to ten decimal numbers Total I/O error count for the path, indicated by up to ten decimal numbers Device number, indicated by up to three decimal numbers. Host device name. In Solaris systems, the mount point is displayed in this field. When the file system is not mounted, a hyphen (-) is displayed.

Note 1: A path that has the same PathName as a path whose state is offline(E) may be in an error status even though its state is online.

48

Chapter 4 Commands

Chapter 5

The HDLM DLMgetras Utility

This chapter describes the DLMgetras utility that HDLM uses to collect error information.

5.1

Overview
HDLM provides a utility called DLMgetras for collecting error information. The user must have root permission to execute DLMgetras. Note: DLMgetras is used in UNIX-based systems only.

5.2

HDLM Details

5.2.1

DLMgetras Format

DLMgetras {directory-for-the-output-destination-of-collected-information [-f file-fordefining-the-information-to-be-collected]|-h}

Figure 5.1

DLMgetras Format

5.2.2

DLMgetras Function
Collects information, such as trace files, definition files, core files and libraries, required for analyzing errors that occur in HDLM. Specify desired files by using the file for defining the information to be collected. For details about the information collected by DLMgetras for collecting error information when you do not use the file for defining information, see Table 5.1.

Note: DLMgetras is used in UNIX-based systems only.

HDLM Users Guide for Sun Solaris Systems

49

5.2.3

Parameters
directory-for-the-output-destination-of-collected-information Specify the output directory. The directories to be output are created in the specified directory, and error information is collected in the created directories. -f file-for-defining-the-information-to-be-collected Specify this parameter when you want to specify the directories or the files to be collected. Specify the directories or the files in the file for defining the information to be collected, and then specify this parameter. Use an absolute path to specify the file for defining the information to be collected (Figure 5.2).

Figure 5.2

Defining Information to be Collected Use absolute paths to specify the directories or files. If you specify the directories or the files in relative paths, the directory where DLMgetras was executed is searched, and the directories and files that are found there are collected. Make sure that the collected information directory is separate from the output destination directory, otherwise an endless loop will result and DLMgetras will never complete. If there is a pound sign (#) at the beginning of a line, the line is considered to be a comment. If there is a pound sign (#) within a line of code, it is considered to be part of a file path. Specify only one file or one directory in one line of code. Do not specify the root directory (/). If you specify a directory, all files in the specified directory are collected. The files in the specified directorys subdirectories are also collected. Note: If the specified directory contains no files, nothing will be collected. The specified directory will not be created in the output destination directory.

Coding rules for -f file-for-defining-the-information-to-be-collected

-h Displays DLMgetras format.

50

Chapter 5 The HDLM DLMgetras Utility

5.2.4

Important Notes
A large amount of data is stored in core files and OS crash files; therefore, sufficient space must be allocated in the directory designated for collecting error information. If the specified output destination directory already exists, a message confirming that directories and files have been overwritten is displayed. When y is entered, the file will be overwritten. When n or any other character is entered, DLMgetras is terminated without being executed.

Table 5.1
Directory

List of Error Information to be Collected by DLMgetras Utility


File dlmmgr1.log dlmmgr2.log Description HDLM manager log file (driver logs are included)

/opt/DynamicLinkManager/log

/opt/hitachi/HNTRLib/mmap /opt/hitachi/HNTRLib/spool /kernel/drv

hntrhost-name.mm hntr{1|2|...|16}.log Note1 sd.conf dlmfdrv.conf dlmadrv.conf fca-pci.conf, fcaw.conf, or lpfc.conf

Memory mapped file Trace files sd (SCSI driver) configuration file HDLM drivers configuration file HDLM alert driver configuration file HBA configuration file (file name depends on the installed HBA driver) Core file configuration definition file OS crash dump configuration definition file Defines the syslog output destination directory Kernel batch file File system automatic mount at startup information file File system mount information Sets the default system type (NFS) and other file system types Sets system boot command execution

/etc

coreadm.conf dumpadm.conf syslog.conf system vfstab

mnttab /etc/dfs fstypes

dfstab

HDLM Users Guide for Sun Solaris Systems

51

Table 5.1
Directory

List of Error Information to be Collected by DLMgetras Utility (Continued)


File OS-crash-file-name Description Collects all files in the DUMPADM_SAVDIR parameter specified directory. Collects all files in the DUMPADM_SAVDIR parameter specified directory. The file path depends on the settings in the /etc/syslog.conf file Directory for collecting the command execution results List of disks that are treated as block devices List of disks that are treated as raw devices Device special file entities Mount information Memory page size OS version OS type (32 bit or 64 bit) System resources limit (data segment, stack segment and file descriptor) available List of installed packages List of installed patches Physical memory size CPU information Kernel parameter value Swap area information Swap usage Loaded drivers information System diagnosis message HDLM path information HDLM system information

/OS-crash-file-directory

/OS-crash-file-directory

OS-crash-file-name

/directory-for-the-output-destination-of-syslog

syslog-name

/getrasinfo

dev_dsk.txt dev_rdsk.txt devices.txt df-k.txt pagesize.txt uname-a.txt isainfo-b.txt ulimit-a.txt

pkginfo.txt showrev-p.txt prtconfMemory.txt psrinfo-v.txt sysdef.txt swap-l.txt swap-s.txt modinfo.txt dmesg.txt dlmmgr-path.txt dlmmgr-sys.txt

Note1: Actual file names are hntr1.log to hntr16.log. 52 Chapter 5 The HDLM DLMgetras Utility

Appendix A

Messages and Alerts

This appendix describes HDLM operational messages and associated required actions. HDLM issues the following message types: HDLM command messages HDLM API messages HDLM manager messages HDLM driver (filter component) messages HDLM alert driver messages HDLM driver (core logic component) messages HDLM management target messages HDLM installation program messages

HDLM Users Guide for Sun Solaris Systems

53

Each message has a unique message ID. Table A.1 contains the message ID format and descriptions. Table A.1
Format KAPL mm

Message Format and Descriptions


Meaning Indicates that the message is a Dynamic Link Manager message. Number of the Dynamic Link Manager module that issued the message. 01: DLM command 03: DLM API 04: DLM manager 05: DLM driver (filter component) 06: DLM alert driver 07: DLM driver (core logic component) 08: DLM management target 09: DLM installation program

nnn l

Message serial number for the module Message level C: Critical E: Error W: Warning I: Information

Table A.2 contains message terminology and definitions. Table A.2


Terminology %d %s %x CS FO LB Operation name Service status Mounted drive

Message Terminology and Definitions


Meaning Decimal number Character string Hexadecimal number Cluster support Failover Load balancing Type of the operation that is entered after dlnkmgr in the command. Running status of the service A drive that the file system recognizes

54

Appendix A Messages and Alerts

Table A.3 contains message numbers, message descriptions, and actions to take, if appropriate. Table A.3
Message Number KAPL01003-W KAPL01004-W KAPL01005-W KAPL01006-W KAPL01007-W KAPL01008-W KAPL01009-W KAPL01011-E KAPL01012-E

Messages and Actions


Message No operation name is specified. The operation name is invalid. Operation name = %s A parameter is invalid. Operation name = %s, parameter = %s A necessary parameter is not specified. Operation name = %s A duplicate parameter is specified. Operation name = %s, parameter = %s A necessary parameter value is not specified. Operation name = %s, parameter = %s A parameter value is invalid. Operation name = %s, parameter = %s, parameter value = %s An invalid interrupt was received during processing of the DLM command. Operation name = %s Action Specify the operation name, and then retry. Execute DLM help operation to check the operation name; retry. Execute DLM help operation to check the parameter; retry. Execute DLM help operation to check the parameter. Specify the correct parameter, and then retry. Delete the duplicate parameter, and then retry. Specify the parameter value, and then retry. Specify the correct value for the parameter, and then retry. Check whether you executed the interrupt or not.

Could not connect the DLM manager. Operation name Execute the view operation of the DLM command to = %s check whether the DLM manager has started. Start the DLM manager if it has not previously started, and then retry the DLM command. An error occurred in internal processing of the DLM command. Operation name = %s details = %s No authority to execute the DLM command. Operation name = %s The target HBA was not found. Operation name = %s The target DKC was not found. Operation name = %s The target LU was not found. Operation name = %s Collect the error information (DLM command log), and then contact maintenance personnel. Execute the command as a user with root permission.. Use the DLM command view operation to check the specification, and then retry. Use the DLM command view operation to check the specification, and then retry. Use the DLM command view operation to check the specification, and then retry.

KAPL01013-E KAPL01014-W KAPL01015-W KAPL01016-W KAPL01017-W KAPL01018-W KAPL01019-W KAPL01021-E KAPL01023-W KAPL01024-W

The target device was not found. Operation name = %s Use the DLM command view operation to check the specification, and then retry. The target path was not found. Operation name = %s Cannot execute the DLM command due to insufficient memory. The last online path for the device cannot be placed offline. Use the DLM command view operation to check the specification, and then retry. Terminate unnecessary applications to increase the amount of free memory, or restart. Use the DLM command view operation to check the status of the path.

Cannot specify the parameters of the DLM command at Execute "help operation-name" of the DLM command the same time. Operation name = %s, parameter = %s to check the parameter that can be specified, and then retry.

HDLM Users Guide for Sun Solaris Systems

55

Message Number KAPL01025-W KAPL01026-E

Message Range of dates is invalid.

Action Specify the correct value in the parameter, and then retry.

A registry access error occurred. Operation name = %s The contents of the managed registry may be damaged. Restart. If the error occurs again after restart, terminate and then uninstall DLM, then reinstall it. Cannot collect log information. Operation name = %s Check disk free space. If the disk has sufficient free space, check whether you have write permission for the log file directory and registry. Also check whether the log file is set to read-only mode.

KAPL01027-E

KAPL01028-E KAPL01029-E

An unexpected error occurred. Processing is canceled. Collect the error information (DLM command log), and Operation name = %s then contact maintenance personnel. A fatal error occurred. Details = Hcc, %s HccCoOutOfMemoryException: A memory shortage coccured. Terminate unnecessary application to increase the amount of free memory, or reset the machine. Other indication: An internal conflict occurred. Collect the error information (HDLM command log),and then contact maintenance personnel.

KAPL01030-E KAPL01031-E KAPL01032-E KAPL01036-E KAPL01037-W KAPL04002-E KAPL04003-E KAPL04005-E KAPL04006-E KAPL04007-E KAPL04008-E

A fatal error occurred. Details = Ansi, %s A %s message was received.

Collect the error information (DLM command log), and then contact maintenance personnel. Collect the error information (DLM command log), and then contact maintenance personnel.

A fatal error occurred. Details = Unexpected exception, Collect the error information (DLM command log), and %s then contact maintenance personnel. The offline path cannot be placed online. PathID=%d Remove the error in the path, and then retry.

Too many parameters are specified. Operation name = Execute help operation-name of the DLM command to %s, parameters = %s check the parameter and retry. Could not start the DLM manager. The startup parameter is invalid. Cannot connect the service control manager. Cannot register the service control handler function. Return value=%d Cannot register the service status. Return value=%d Cannot open the option definition file (%s). Check for any other errors. Check the specification of the startup parameter. See section 3.2.2 and section 3.2.3 on starting and stopping the HDLM manager. Contact maintenance personnel. Contact maintenance personnel. Check to see if another program is using the file (or has opened the file with Notepad), or if the file has been deleted inadvertently. If you edited the option definition file, check the contents of the file. If you did not, check the file for damage. After checking the file for damage, restart the DLM manager. If the same error occurs again, reinstall DLM.

KAPL04009-E

The option definition is invalid.

56

Appendix A Messages and Alerts

Message Number KAPL04010-E

Message Could not open the error log file.

Action Check to see if another program is using the file (or has opened the file with Notepad), or whether the file has been deleted inadvertently. Check that the disk has sufficient free space. Contact maintenance personnel.

KAPL04011-E KAPL04012-E KAPL04013-E KAPL04014-E KAPL04016-E KAPL04017-E KAPL04018-E KAPL04019-E KAPL04022-W KAPL04023-E KAPL04024-C KAPL04025-C KAPL05003-I KAPL05004-I KAPL05005-I KAPL05006-I KAPL05007-E

Could not output the error log file. Could not create a communication pipe. RC=%d

Input is impossible via the communication pipe. RC=%d Contact maintenance personnel. Output is impossible via the communication pipe. RC=%d The option is invalid. Output of the option definition file was impossible. Could not close the option definition file. Could not collect the error information. RC=%d DLM manager warning information - %s DLM manager error information - %s A critical error occurred in the DLM manager. (%s) A memory shortage occurred in the DLM manager. The DLM driver (filter component) is successfully attached to Disk (%d), Partition (%d). Initialization of the filtering function (%x) for the DLM driver (filter component) was successful. Initialization of the control function (%x) for the DLM driver (filter component) was successful. Connection with the DLM alert driver was successful. Could not connect the DLM alert driver. (%x:%x) Contact maintenance personnel. Specify the correct option. Check that the disk has sufficient free space. Check that the disk has sufficient free space. Check that the DLM driver (alert component) is running. Analyze the contents of the warning. Analyze the error information. Examine the error for the cause. Increase the amount of memory available for the process. None. None. None. None. Check to see if the DLM alert driver has started. If it has stopped, restart the machine. If this message frequently appears when the DLM alert driver has started, contact maintenance personnel.

KAPL05008-E

Could not allocate memory. (%x:%x)

Check to see if the DLM driver has started normally. If it has not started or contains an error, contact maintenance personnel and report the error and detail code. Check to see if the DLM driver has started normally. If it has not started or contains an error, contact maintenance personnel and report the error and detail code. Check to see if the DLM driver has started normally. If it has not started or contains an error, contact maintenance personnel and report the error and detail code.

KAPL05009-E

Could not start the thread (%x). (%x:%x)

KAPL05010-E

Could not initialize the DLM driver (filter component). (%x:%x)

HDLM Users Guide for Sun Solaris Systems

57

Message Number KAPL05011-E

Message Could not attach the DLM driver (filter component) to Disk (%d), Partition (%d). (%x:%x)

Action Check to see if the DLM driver has started normally. If it has not started or contains an error, contact maintenance personnel and report the error and detail code. None. This is normal operation. If the target drive cannot be referenced, check the disk configuration. None. The I/O being processed is discarded. Check the status of the path and take an appropriate action. None.

KAPL05012-I KAPL05013-I KAPL05014-I KAPL05018-W KAPL05019-I KAPL05022-I KAPL05023-E

The device (%x) for Disk (%d), Partition (%d) is selected for a mounted drive. The device (%x) for Disk (%d), Partition (%d) is removed from the mounted drives. The device object (%x) is registered as the path (%x). The FO processing in the path (%x) failed. (%x:%x) The FO processing in the path (%x) finished. The I/O request is processed in the path (%x).

An invalid IOCTL (%x) was received. The processing is None. canceled. Could not process the IOCTL (%x). (%x:%x) Check the message of the DLM command or DLM manager. If this message frequently appears, contact maintenance personnel and report the error and detail code.

KAPL05024-E

Could not output a log to the DLM alert driver. (%x:%x) Check whether the DLM alert driver has started. If this message frequently appears when the DLM alert driver has started, contact maintenance personnel.

KAPL05026-E

An error occurred when the DLM driver (filter component) terminated. (%x:%x) The DLM driver (filter component) (%x) received an UNLOAD request. The request was canceled. Invalid processing (%x) was detected. The DLM driver (filter component) will now terminate abnormally. (%x:%x)

Check that the DLM driver completed normally. If you find any problems, contact maintenance personnel and report the error and detail code. None. You cannot stop the DLM driver. Since an unrecoverable error was detected, the DLM driver terminated. Contact maintenance personnel and report the error and detail code.

KAPL05027-I KAPL05028-C

KAPL05029-I

The MajorFunction (%x) that the DLM driver (filter None. component) does not handle was received. The request was transferred to the disk class driver. An unsupported MajorFunction (%x) was requested. The request was canceled. Disk(%d) is not a target disk system for DLM.(%x,%x) None. If this message frequently appears, check whether an invalid program is running. If this message is displayed for a disk that is not supported by HDML, there is no problem. If this message is displayed for a disk that is supported by HDML, contact maintenance personnel.

KAPL05030-W KAPL05031-W

KAPL05032-I KAPL05033-W

The path health checking for the path (%x) completed normally. (%d,%x) The path health checking for the path (%x) failed. (%d,%x,%x)

None. Check the path for which path health checking failed. If this message is displayed for an unexpected path, contact maintenance personnel.

58

Appendix A Messages and Alerts

Message Number KAPL05034-I KAPL05035-I KAPL05036-E

Message Disk(%d) is a target disk system for DLM. (%x,%x) The DLM driver (filter component (%x)) is successfully attached to the device object (%d).

Action None. None.

Failed to attach the DLM driver (filter component (%x)) Check whether the DLM driver has started normally. If to the device object (%d). it has not started or contains an error, contact maintenance personnel and report the error and detail code. Initialization of the DLM alert driver (%x) was successful. Could not allocate memory. (%x:%x) None. Check to see if the DLM driver has started normally. If it has not started or contains an error, contact maintenance personnel and report the error and detail code. Check whether the DLM driver has started normally. If it has not started or contains an error, contact maintenance personnel and report the error and detail code. Check whether the DLM driver has started normally. If it has not started or contains an error, contact maintenance personnel and report the error and detail code. None. Check the message of the DLM command or DLM manager. If this message frequently appears, contact maintenance personnel and report the error and detail code. Check that the DLM manager is running. If it is not, start the DLM manager.

KAPL06003-I KAPL06004-E

KAPL06005-E

Could not initialize the DLM alert driver. (%x:%x)

KAPL06006-E

Could not start the thread (%x). (%x:%x)

KAPL06009-I KAPL06010-E

Invalid IOCTL (%x) was received. The processing is canceled. Could not process the IOCTL (%x). (%x:%x)

KAPL06011-W KAPL06012-W

Old log information was discarded because the log buffer did not have enough free space. (%x:%x)

Old emergency information was discarded because the Check that the DLM manager is running. If it is not, emergency information buffer did not have enough free start the DLM manager. space. (%x:%x) Could not write log information into the log buffer. (%x:%x) Could not write emergency information into the emergency information buffer. (%x:%x) The contents of the log buffer are discarded. Check whether any other error occurred. The log information that could not be written is discarded. Check whether any other error occurred. The log information that could not be written is discarded. The DLM manager could not correctly save the log information in the file during termination. Check whether any other error occurred. The DLM manager could not correctly save the log information in the file during termination. Check whether any other error occurred. None. If this message frequently appears, check for an invalid program running. Check that the DLM driver completed normally. If you find any problem, contact maintenance personnel and report the error and detail code.

KAPL06013-E KAPL06014-E KAPL06015-W

KAPL06016-W

The contents of the emergency information buffer are discarded. An unsupported MajorFunction (%x) was requested. The request was canceled. An error occurred during termination of the DLM alert driver. (%x:%x)

KAPL06018-W KAPL06019-E

HDLM Users Guide for Sun Solaris Systems

59

Message Number KAPL06020-I KAPL06021-C

Message The DLM alert driver (%x) received an UNLOAD request. The request was canceled. Invalid processing (%x) was detected. The DLM alert driver will now terminate abnormally. (%x:%x) An internal conflict occurred in the DLM driver (core logic component). Stage%d

Action None. You cannot stop the DLM alert driver. Since an unrecoverable error was detected, the DLM alert driver terminated. Contact maintenance personnel and report the error and detail code. Restart the system.

KAPL07000-C KAPL07002-C KAPL07050-C KAPL07054-E KAPL07100-C KAPL07150-C KAPL07151-I KAPL07152-I KAPL07153-W KAPL07154-W KAPL07155-W KAPL07157-W KAPL07158-W KAPL07200-C KAPL07201-W KAPL07203-W KAPL07204-W KAPL07208-E KAPL07250-C KAPL07251-W KAPL07254-W KAPL07255-W

Could not enlarge the memory area for the DLM driver. Restart the system. An internal conflict occurred in the DLM driver (core logic component). Stage%d Could not create an DLM driver table. Stage%d An internal conflict occurred in the DLM driver (core logic component). Stage%d An internal conflict occurred in the DLM driver (core logic component). Stage%d The error path was recovered successfully. The error path and offline path were recovered successfully. Restart the system. Restart the system. Restart the system. Restart the system. None. None.

The request was ignored because access to the path at None. the media level was impossible. Could not recover the error path. Could not recover the error path and offline path. Could not recover some of the paths related to the specified device. Could not recover the paths related to the specified device. An internal conflict occurred in the DLM driver (core logic component). Stage%d The configuration does not contain a standby path. A nonexistent path is specified for the main path. Although an owner path exists, a non-owner path is selected for the main path. There is no standby path. ID%d An internal conflict occurred in the DLM driver (core logic component). Stage%d The configuration is not applicable to LB. Check the specified path again. If the specification is correct, you need to investigate further. Check the specified paths again. If the specification is correct, you need to investigate further. Check the specified paths again. If the specification is correct, you need to investigate further. Check the specified paths again. If the specification is correct, you need to investigate further. Restart the system. Check the configuration. None. Check the specification. Check the specification. Restart the system. Check the configuration.

A path that cannot be a target of LB is specified. ID%d Check the specification. An attempt was made to remove the last LB target from Check the specification. the LB target path. ID%d

60

Appendix A Messages and Alerts

Message Number KAPL07258-E KAPL07300-C KAPL07304-E KAPL07307-E KAPL07350-C KAPL07355-W KAPL07357-C KAPL07360-C KAPL07372-C KAPL07374-C KAPL07400-C KAPL07404-I KAPL07405-I KAPL07406-I KAPL07407-I KAPL07442-W KAPL07443-W KAPL07453-W KAPL07550-C KAPL07551-W KAPL07552-W KAPL08019-E KAPL08020-E

Message There is no path-switching destination. ID%d An internal conflict occurred in the DLM driver (core logic component). Stage%d An error in the standby path cancels the CS function forcibly. The CS function could not retry. An internal conflict occurred in the DLM driver (core logic component). Stage%d An attempt to place the last path offline was rejected. ID%d Could not place the path offline. ID%d Could not release the offline path. ID%d Could not place all the paths offline. Could not make some of the paths related to the specified device offline. An internal conflict occurred in the DLM driver (core logic component). Stage%d The processor reduction for defusing an error is enabled.

Action Check the specification. Restart the system. Check the cause of the error. Check the cause of the error. Restart the system. Check the specification. Check the specified path again. If the specification is correct, investigate further. Check the specified path again. If the specification is correct, investigate further. Check the specified path again. If the specification is correct, investigate further. Check the specified path again. If the specification is correct, investigate further. Restart the system. None.

A request was made to enable the processor reduction None. for defusing an error when it was already enabled. A request was made to disable the processor reduction None. for defusing an error when it was already disabled. The processor reduction for defusing an error is disabled. The path is not the target of management for the specified LU/device. ID%d, ID%d An error path was specified. ID%d, ID%d The target of the CS function is not a single LU containing a single device. ID%d, ID%d An internal conflict occurred in the DLM driver (core logic component). Stage%d None. Check the specification. Check the specification. Check the specification. Restart the system.

Recovery instruction was made in response to the error None. report. Recovery instruction was made in response to an unknown error report. The path (%x) detected an error (%x). (%s) I/O processing in the path (%x) terminated with error (%x). (%s) Investigate the cause of the error. Check the path that detected the error. Check the path that detected the error.

HDLM Users Guide for Sun Solaris Systems

61

Message Number KAPL08021-E

Message

Action

I/O processing in the path (%x) in Disk (%d), Partition The failover function has no effect if there is only one (%d) failed due to an error (%x). Failover is performed. online path in the path class. Check the error in the path and take an appropriate action. A path error occurred. ErrorCode=%d, PathID=%d, PathName=%d.%d.%d.%d, DNum=%d, HDevName=%s A path was recovered. PathID=%d, PathName=%d.%d.%d.%d, DNum=%d, HDevName=%s There is no system management permission. The disk does not have sufficient free space. The hardware targeted to be controlled may have a problem. For details on the action to be taken, see section 3.4.1. None.

KAPL08022-E

KAPL08023-E

KAPL09001-E KAPL09002-E

Execute the command as a user with root permission.. Change the installation destination or delete unnecessary files to increase the amount of free space; retry. Install HDLM in an AIX or Solaris SPARC system. Stop the DLM manager manually. Then, re-execute the installation program or the uninstallation program. If installation was interrupted, incomplete files and directories may remain. Delete such files and directories. Check the license code, and then re-enter it. Check the license code, and then re-execute the installation program. Check the parameters for the error-information collection utility and then retry. Check the parameters for the error-information collection utility and then retry. Check the parameters for the error-information collection utility and then retry. Check the parameters for the error-information collection utility and then retry. Check the parameters for the error-information collection utility and then retry. Check whether the indicated collection-information definition file exists. Alternatively, check for access permission or the like. Check the parameters for the error-information collection utility and then retry. Check the access permission for the specified directory. Also, check whether the specified directory name is correct. The specified directory already exists. Enter y to overwrite. Enter n or any other key to terminate the error-information collection utility without executing it.

KAPL09003-E KAPL09005-E KAPL09006-E

Cannot install in this system. Could not stop the DLM manager. Could not install Dynamic Link Manager.

KAPL09008-W KAPL09009-E KAPL10001-W KAPL10002-W KAPL10003-W KAPL10004-W KAPL10005-W KAPL10006-W

The license code is invalid. The license code is invalid. The DLM installation program will now terminate. No parameter is specified. There are too many parameters. Something other than a directory name has been specified in the first parameter. value = %s The parameter has an incorrect value. value = %s There is an insufficient number of parameters. The file name for collection information definition does not exist or cannot be read. value = %s A directory name has been specified in the third parameter. value = %s The user does not have write permission for the specified directory. value = %s The specified directory name already exists. Do you want to overwrite? [y/n]:

KAPL10007-W KAPL10008-W

KAPL10009-W

62

Appendix A Messages and Alerts

Message Number KAPL10010-W

Message A root directory has been specified. line = %d

Action Delete the coding of the root directory from the specified file. The displayed directory will be ignored and the error-information collection utility will continue.

KAPL10011-W

More than one file or directory name has been specified After the error-information collection utility terminates, on one line. line = %d, value = %s check the contents of the collection-information definition file shown in the message. If the contents are incorrect, correct them and then re-obtain the error information. The displayed file or directory will be ignored and the error-information collection utility will continue. This message is output up to five times and then omitted. The specified file name or directory name does not exist. line = %d, value = %s After the error-information collection utility terminates, check the contents of the collection-information definition file shown in the message. If the contents are incorrect, correct them and then re-obtain the error information. The displayed file or directory will be ignored and the error-information collection utility will continue. After the error-information collection utility terminates, check the contents of the collection-information definition file shown in the message. If the contents are incorrect, correct them and then re-obtain the error information. The displayed file will be ignored and the error-information collection utility will continue. After the error-information collection utility terminates, check the contents of the collection-information definition file shown in the message. If the contents are incorrect, correct them and then re-obtain the error information. The displayed directory will be ignored and the error-information collection utility will continue. After the error-information collection utility terminates, check whether the collection-information definition file shown in the message is a text file. None The error-information collection utility will terminate halfway. If the directory is unnecessary, delete it including the subordinate files.

KAPL10012-W

KAPL10013-W

The user does not have read permission for the specified file. line = %d, value = %s

KAPL10014-W

The user does not have read permission for the specified directory. line = %d, value = %s

KAPL10015-W

The file format is incorrect. value = %s

KAPL10020-I KAPL10021-I

The file has been obtained successfully. file = %s Processing terminated halfway because a signal was received.

HDLM Users Guide for Sun Solaris Systems

63

64

Appendix A Messages and Alerts

Acronyms and Abbreviations


ASCII BL CKD CR CVS D DAT DO DS EA EBCDIC Emp EOF FC FCU FD FWD GUI ICKDSF American National Standard Code for Information Interchange block length count key data carriage return custom volume size delimiter digital audio tape dataset organization dataset size EBCDIC/ASCII (includes EBCDIC-to-ASCII and ASCII-to-EBCDIC) extended binary-coded decimal interchange code empty file option end of file fibre channel File Conversion Utility floppy disk fast-wide differential graphical user interface A Device Support Facilities (DSF) command used to perform media maintenance kilobytes logical device line feed Logical Storage Manager logical unit logical unit number Logical volume image mainframe mainframe-to-open standard LU type, e.g., OPEN-3, OPEN-9 operating system open-to-mainframe open-to-open record 0 record description word record format record length HDLM Users Guide for Sun Solaris Systems 65

kB LDEV LF LSM LU LUN LVI MF mto OPEN-x OS otm oto R0 RDW RF RL

SCSI volser VSN VTOC

small computer system interface volume serial number volume serial number volume table of contents

66

Acronyms and Abbreviations

Index
A
actions taken for a path error, 37 actions taken for a program error, 38

R S
SCSI Bus number, 34 SCSI Port number, 34 State, 35

B
bus number, 34

C
contacting maintenance personnel, 39 core logic component, 26

T
taking the action for the error, 39 target Id, 34

D
DkcPort, 35 DLM alert driver, 26 DLM command, 26 DLM driver, 26 DLM manager, 26 DNum, 35

V
vendor ID, 34

H
HDevName, 35

I
identifying the error section and taking corrective action for the hardware, 38 iLU, 34

L
Logical Unit Id, 34 LUN, 34

M
monitoring the message, 39

N
narrowing down the hardware that may have the error, 38

O
obtaining program information, 39 obtaining the path information, 37 operations, 42 operations of the HDLM command, 42

P
path health checking, 36 port number of the host bus adapter, 34 product ID, 34

HDLM Users Guide for Sun Solaris Systems

67

68

Index