You are on page 1of 11

SIPROTEC Numerical Protection Relays

Protection Systems Catalog SIP 2008

www.siemens.com/energy

Editorial

SIPROTEC more than just protection


This edition of the SIPROTEC catalog incorporates many suggestions from our readers, along with information about innovations and supplementary products. In the field of power distribution and consumption, SIEMENS now offers a new family of SIPROTEC Compact devices. The 7SJ80 line protection relay offers a vast amount of functionality in a compact housing at an affordable price. The functional packages of 7SK80 are especially designed for protection and management of asynchronous motors of all sizes. Of course, the family has full native IEC 61850 capability besides supporting all other major communication protocols, for seamless integration into all kinds of system environments. This is exactly what you would expect because SIPROTEC stands for innovation, reliability and integration into protection and control. Another new family member is the web-based Power Quality monitoring and analysis suite, SIMEAS SAFIR. From now on, you will be able to effectively analyze network disturbances and take corrective action in a matter of minutes, no matter where you are. Take a few minutes to work through the SIMEAS SAFIR tutorial and you will be delighted by the benefits of the product. IEC 61850 has become established as the communication backbone for the new era of energy automation and control, and SIPROTEC is its highlight. We are happy to share with you all the references and experience we have gathered in recent years. For your convenience, this SIPROTEC catalog is also available on CD ROM. For further information on SIPROTEC applications and features, our local Siemens representative will assist you, but dont miss the interactive multimedia DVD SIPROTEC Tutorial, which will guide you through many of these features. To receive this media free of charge, just ask your local Siemens representative or send us an e-mail (support.energy@siemens.de). We compiled this catalog with your needs in mind and hope it will assist you to optimally and conveniently select from among the available features and products. We wish you a pleasant and productive experience with SIPROTEC. Paulo Ricardo Stark Vice President Energy Distribution Energy Automation Protection and Power Quality Systems Division Ensuring reliable energy supply.

Contents
Product Selection

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

Overview/Applications

Operating Programs

SIPROTEC Numerical Protection Relays

Communication

Overcurrent Protection

Distance Protection

Line Differential Protection

Transformer Differential Protection

Busbar Differential Protection

Relays for Various Protection Applications

Generator Protection

Motor Protection

Power Quality

Substation Automation

Relay Communication Equipment

Catalog SIP 2008


Supersedes Catalog SIP 2006 Siemens AG 2008

Test Equipment and Accessories

Appendix

Product Index
Type DIGSI 4 OSCOP P SICAM PAS SIGRA 4 SIMEAS P SIMEAS Q SIMEAS R SIMEAS T SIMEAS SAFIR 3RV1 6MD61 6MD63 6MD66 6MD9 7PA22/23 7PA26/27 7PA30 7RW6 7SA522 7SA6 7SD5 7SD60 7SD61 7SJ45 easy 7SJ46 easy 7SJ600 7SJ602 7SJ80 7SJ61 7SJ62 7SJ63 7SJ64 7SK80 7SN60 7SS52 7SS60 7SV6
2

Description Operating software for SIPROTEC devices Operating software for power quality Substation automation system Evaluation software for fault records Power meter Power quality recorder Disturbance recorder and PQ monitoring unit Digital transducer Analysis and monitoring software for power quality Voltage transformer mini circuit-breaker IO-box Bay control unit High-voltage bay control unit Substation automation system Auxiliary relay Auxiliary relay Trip circuit supervision Voltage, frequency and overexcitation relay Distance protection relay for transmission lines Distance protection relay for all voltage levels Multi-end differential protection relay Pilot-wire current differential protection relay Differential protection relay for 2 line ends Overcurrent protection relay powered by CT Overcurrent protection relay Overcurrent, motor and overload protection relay Overcurrent, motor and overload protection relay Multifunction protection relay Multifunction protection relay Multifunction protection relay Multifunction protection relay Multifunction protection relay with synchronization Motor protection relay Transient earth-fault protection relay Distributed busbar and breaker failure protection Centralized busbar protection Numerical circuit-breaker failure protection relay

Page 3/7 13/67 14/3 3/12 13/3 13/31 13/41 13/19 13/79 16/17 14/11 14/19 14/21 14/3 16/5 16/9 16/12 11/71 6/45 6/3 7/43 7/3 7/17 5/3 5/11 5/19 5/31 5/55 5/77 5/105 5/143 5/183 12/9 10/31 9/19 9/3 10/21
Siemens SIP 2008

Product Index
Type 7TS 16 7UM61 7UM62 7UT6 7UW5 7VE6 7VK6 7XV5101 7XV5103 7XV5104 7XV5105 7XV5300 7XV5450 7XV5461 7XV5461 7XV5461 7XV5550 7XV5650/5651 7XV5652 7XV5653 7XV5654 7XV5655 7XV5655 7XV5662 7XV5662 7XV5662 7XV5662 7XV5664 7XV57 7XV5710 7XV5820 7XV5850/51 7XV75 Description Annunciation relay Multifunction generator and motor protection relay Multifunction generator, motor and transformer protection relay Differential protection relay for transformers, generators, motors and busbars Tripping matrix Multifunction paralleling device Breaker management relay RS232 FO connector modules RS485 Bus system Bus cables for time synchronization Bus cables for time synchronization for 7SD5 Star coupler Mini star-coupler Two-channel serial optical repeater for mono-mode FO cable Two-channel serial optical repeater for 1 mono-mode FO cable Two-channel serial optical repeater for multi-mode FO cables Active mini star-coupler RS485 FO converter RS232 FO converter Two-channel binary transducer GPS/DCF77 Time synchronization unit Ethernet modem Ethernet serial hub for substations Communication converter for X.21/RS422 and G.703.1 Communication converter for pilot wires Two-channel serial communication converter Temperature monitoring box GPS/DCF77 Time signal receiver RS232 RS485 converter USB RS485 converter cable Industrial modem and modem-router with switch Ethernet modems for office applications Test switch Page 16/13 11/3 11/33 8/3 11/69 11/81 10/3 15/3 15/5 15/13 15/15 15/17 15/19 15/23 15/27 15/31 15/35 15/39 15/43 15/47 15/67 15/69 15/73 15/51 15/55 15/59 15/63 15/67 15/77 15/81 15/85 15/95 16/3

Siemens SIP 2008

Siemens SIP 2008

Product Selection
Relay Functions

Page 1/2

1 Product Selection

Relay Functions
Pilot wire differential Line differential

7SD600 7SD5 7SD610

Protection functions ANSI No.* 14 21 21N 21FL 24 25 27 27/34 32 32F 32R 37 40 46 47 48 49 49R 49S 50 50N 50BF 51GN 51 51N 51M 51V 59 59N 59GN 64 64R
n l

Type

Description Locked rotor protection Distance protection, phase Distance protection, earth (ground) Fault locator Overfluxing (V/f protection) Synchronizing, synchronism check Undervoltage Stator earth-fault 3 harmonic Directional power Forward power Reverse power Undercurrent or underpower Loss of field Load unbalance, negative phasesequence overcurrent Phase-sequence voltage Motor starting protection Thermal overload Rotor thermal protection Stator thermal protection Instantaneous overcurrent Instantaneous earth-fault overcurrent Breaker failure Zero speed and underspeed device Overcurrent-time relay, phase Overcurrent-time relay, earth Load jam protection Overcurrent-time relay, voltage controlled Overvoltage Residual voltage earth-fault protection Stator earth-fault protection 100 % Stator earth-fault protection (20 Hz) Rotor earth fault
rd


n n n n n n


l l l


n l l


l l l l


l l


l l


n n


l l l n


n n n n n n n


n n n n n n n n l n n n n n


n n n n


n n n n n


n n n n n n


n n n n


n n n n


n n n n n n l n n l n n l n n l n n n


l l l l


l l


n l l

Standard function Option * ANSI/EEE C 37.2: IEEE Standard Electrical Power System Device Function Numbers

1/2

7SJ45 7SJ46 7SJ600 7SJ602 7SJ80 7SJ61 7SJ62 7SJ63 7SJ64 7SK80 7VH60 7UT612 7UT613 7UT63 7SS60 7SS52
l l l l n

7SA522 7SA6


l l

Motor protection Differential


Overcurrent

Distance

q
l

l l


l l

q q q
n

l l l n

l l l n

l n n n n n

n l n n n n n

n l n n n n n

n l n n n n n

l n n n n n n


n n n


n n


n n n n n n

l l

n n

n n

n n

l l

s
l n

l n

s
l n


l l

Siemens SIP 2008

1 Product Selection

Breaker management Synchronizing

1
Breaker failure Voltage, frequency

n

Generator and motor protection

Protection functions ANSI No.* 14 21 21N 21FL 24 25 27 27/34 32 32F 32R 37 40 46 47 48 49 49R 49S 50 50N 50BF 51GN 51 51N 51M 51V 59 59N 59GN 64 64R
n l

Type

Description Locked rotor protection Distance protection, phase Distance protection, earth Fault locator Overfluxing (V/f protection) Synchronizing, synchronism check Undervoltage Stator earth-fault 3 harmonic Directional power Forward power Reverse power Undercurrent or underpower Loss of field Load unbalance, negative phasesequence overcurrent Phase-sequence voltage Incomplete sequence, locked rotor Thermal overload Rotor thermal protection Stator thermal protection Instantaneous overcurrent Instantaneous earth-fault overcurrent Breaker failure Zero speed and underspeed dev. Overcurrent-time relay, phase Overcurrent-time relay, earth Load jam protection Overcurrent-time relay, voltage controlled Overvoltage Residual voltage earthfault protection Stator earth-fault protection 100 % Stator earth-fault protection (20 Hz) Rotor earth fault
rd
n n n n


n l n l


n n


n n n n n n n n n l

l n

l l

n l n

n l n n n n n

n n n

n n n n

n n


l l


n n

n n

n n

n l

Standard function Option * ANSI/EEE C 37.2: IEEE Standard Electrical Power System Device Function Numbers

Siemens SIP 2008

7SV600 7RW600

7UM61 7UM62

7VK61 7VE6

1/3

1 Product Selection

Relay Functions
Pilot wire differential

Motor protection

Line differential

Overcurrent

7SD600

7SD610

Differential 7UT612 7UT613 7VH60

7SA522

Distance

7SJ600

7SJ602

7UT63

l

7SK80

7SS60

n

Protection functions ANSI No.* 67 67N 67G 68 74TC 78 79 81 81R 85 86 87G 87T 87BB 87M 87L 87N Description Directional overcurrent

Type


l n

q q

n 1)

l l

q q

q q

q q

Directional earth-fault overcurrent Stator earth-fault directional overcurrent Power swing detection Trip circuit supervision Out-of-step protection Auto-reclosure Frequency protection Rate-of-frequency-change protection Vector jump supervision Carrier interface/remote trip Lockout function Differential protection generator Differential protection transformer Differential protection busbar Differential protection motor Differential protection line Restricted earth-fault protection

l n

l n

l n

l n

l n

l l

l l l

l l

l l

l l


l l


n n n n n n l


n n n n n n l


n n


n n


n n


n n


n n n n n n l

Standard function Option * ANSI/EEE C 37.2: IEEE Standard Electrical Power System Device Function Numbers 1) only sensitive directional earth-fault overcurrent (67Ns)
l

1/4

Siemens SIP 2008

7SS52

n

7SJ45

7SJ46

7SJ80

7SJ61

7SJ62

7SJ63

7SJ64

7SD5

7SA6

1 Product Selection

Breaker management Synchronizing

1
Breaker failure Voltage, frequency

n l

Generator and motor protection

Protection functions ANSI No.* 67 67N 67G 68 74TC 78 79 81 81R 85 86 87G 87T 87BB 87M 87L 87N Description Directional overcurrent

Type

n n n

n n n

Directional earth-fault overcurrent Stator earth-fault directional overcurrent Power swing detection Trip circuit supervision Out-of-step protection Auto-reclosure Frequency protection Rate-of-frequency-change protection Vector jump supervision Carrier interface/remote trip Lockout function Differential protection generator Differential protection transformer Differential protection busbar Differential protection motor Differential protection line Restricted earth-fault protection

l n n


l l l

n l l


n l l


n n n n

Standard function Option * ANSI/EEE C 37.2: IEEE Standard Electrical Power System Device Function Numbers
l

Siemens SIP 2008

7SV600 7RW600

7UM61 7UM62

7VK61 7VE6

1/5

You might also like